You are on page 1of 4

RO-S SERIES

WA TER POT ABILIZA TION RO T REA TMENT PLANTS

LABEAU TUNISIE - TUNISIE

ROS SeriEs
WATER POTABILIZATION TREATMENT SYSTEM 60-1000 m3/day (16000-285000GPD) For water purification: SYSTEMES DE PRODUCTION EAU POTABLE 60-1000 m3/day (16000-285000GPD) Systme pour la purification deleau saumtre jusqu 20.000 TDS,

removing more than 98% of media and more than 99% of colloids and other organic matter. THE ROS SYSTEMS: Each ROS systems consist of following stages: - Self carrying Structure - dimension 6000/3500x1400/1200x1400h. mm. in the standard version, built with steel galvanized and painted structure with facility transportation. - All the instrumentation, the pressure gauges, the commandos and the emergency devices are placeed on the frontal panel of the system. - Heavy duty 40 5m sediment Multifilter - external case PVC or AISI304 - High pressure pump. Stainless stell AISI316L high pressure Up Vertical multistage pump (400V). - ROS Systems include reverse osmosis modules, production is 60-1000m3/hour (16000-285000GPD) Its possible to feed the system with high SDI water. - Automatic electronic system control display: - System in operation indicator - Conductivity inlet and outlet - Lighted On/Off controls - Pressure inlet - Automatic control of stand-by and cleaning of reverse osmosis membranes. - Automatic dosing system for antiscalant product. For the elevated capacity of this system is very important a water feeding analysis for the right choice of pretreatment system. So high capacity Water softners, Dechlorine and automatic system for the removal of Iron, Manganese and other are available PROCESS: The RO process uses membranes to remove dissolved solids, organics, pyrogens and bacteria from water. RO also removes sodium, chloride, hardness, fertilizers, insecticides, arsenic, heavy metals and many other contaminants. Most importantly, RO reduces total dissolved solids (TDS). RoPlant standard production includes a simple pretreatment as a sediment and carbon filter and a more detailed as an

apte produire de leau usage industriel, potable, lirrigation et le processus. ROS machines comprennent: - Structure autosuffisant - version standard dimension: 3500/6000x1200/1400x1800/1900h.mm. second modle. Construit de mtal galvanis et peint haute rsistance - Tous le instruments, les jauges, les commandos et les dispositifs durgence sont dplacs sur le panneau frontal du systme. - Robuste 40 longuer 5m sdiments multifilter - caisse externe PVC ou AISI316 raliss. - Pompe haute pression: multicellulaires verticales (400V) AISI316L ralis - Le ROS systmes comprende des modules dosmose inverse pour la productione entre 60 et 1000m3/hour (16000-285000GPD) second modle. - Il est possible dalimenter le systme avec de leau haute SDI avec prtraitments spcifiques. - Le contrle et laffichage sont ralises par les Labeau automate lectronique PLC dispositif Le dispositif affiche: - Ltat du systme - Conductivit dentre et de sortie - Pression dentre - Pression pompe haute pression - Commande automatique de la stand-by et le nettoyage des membranes dosmose inverse. - Systme automatique de dosage pour le produit antitatre. - Systme automatique de dosage pour le produit biocide, etc . (second modl) Pour le capacit leve de ce systme est trs important de lanalyse de leau dalimentation pour le choix du systme de prtraitment. Sont disponibles: adoucisseurs deau, dechlorine systme, automatique systme pour llimination du fer, de manganse. PROCESSUS: Les processus de losmose inverse utiles des membranes pour

antiscalent feeder for very hard water in high efficiency RO systems.


Other pretreatment methods are determined through a water analysis. SYSTEM CONTROL The system is controlled by Labeau PLC that verifies every single parameter in order to assure and to verify continuously the operations. Main Features: - Acustic and visual Alarm - Inlet/outlet pressure - Display of TDS/Conductivity, pH, Temperature C and % of recovery - Total hour meter - Membranes auto flush system and built-in cleaning system - The equipment is factory tested and sterilized prior to shipment - All components are high quality with FDZ/NSF approval - Mixing valve for adjusting quality of permeate water. For the elevated capacity of this system is very important a water feeding analysis for the right choice of pretreatment.

eliminer les matires dissoutes dans leau, matire organique, les bactries et les pyrognes. Osmose inverse limine galement de sodium, chlorure, duret, engrais, insecticides, larsenic, des mtaux lourds et plusieurs autres contaminants. Osmose Inverse surtout rduit la TDS total solides dissous. Les modles standard de la srie ROS comprennent un simple pretraitment comme un filtre sdimentes, un filtre charbon et une dose unitaire de antitartre. Dautres mthodes de pretraitment sont tablis par lanalyse de leau entrante. SYSTEME DE CONTROLE Le systme est contrl par PLC Labeau qui vrifie chaque paramtre afin dassurer et de vrifier en permanence les oprations. Caractristiques principales: - Alarme visuelle et Acustic - CIP - nettoyage intgr du systme - Affichage de TDS / conductivit, pH, temprature C et% de rcupration Total compteur horaire auto purger le systme de membranes et de nettoyage intgr du systme - Le matriel est test en usine et strilis avant lexpdition - Tous les composants sont de haute qualit avec FDZ / NSF - Vanne de mlange pour ajuster la qualit de leau de permat.

LABEAU TUNISIE sarl - TUNIS


Water Treatment Systems Production
www.labeau-tn.com - info@labeau-tn.com
TUNISIE - 5 rue Imam Abu Hanifa - 02083 La Petite Ariana

Tel.+216-27045506

LABEAU08012800 05/12 Printed in tunisie