You are on page 1of 10

Column Block Reference Manual

ReCon Series 50

Aesthetics You Want Performance You Need!

www.reconwalls.com
Copyright 2011 ReCon Wall Systems, Inc.

Table of Contents
ReCon Series 50 Column Block Catalog .......................................................................................................... 4 Free Standing Column ........................................................................................................................................ 5 Column Block with Fence .................................................................................................................................. 6 Column Block with Fence Rails ......................................................................................................................... 7 Column Block with Gate .....................................................................................................................................8

Page 3

ReCon Series 50 Column Block Catalog


OCTOBER 2012

RECON SERIES 50 COLUMN BLOCK CATALOG


Name Weight 773 Unit ID CB Volume 5.33

Column Block
Dimensions 16 in. x 24 in. x 24 in.

Name Weight 753 Unit ID CBFRR Volume 5.20

Column Block for Fence Rail - Runner


Dimensions 16 in. x 24 in. x 24 in.

Name Weight 735 Unit ID CBCR Volume 5.07

Column Block for Conduit / Reinforcement


Dimensions 16 in. x 24 in. x 24 in.

Name Weight 763 Unit ID CBFRE Volume 5.26

Column Block for Fence Rail - End


Dimensions 16 in. x 24 in. x 24 in.

Name Weight 753 Unit ID CBFRC Volume 5.20

Column Block for Fence Rail - Corner


Dimensions 16 in. x 24 in. x 24 in.

Name Weight 369 Unit ID CC Volume 2.54

Column Cap
Dimensions 6.5 in. x 26 in. x 26 in.

Name Weight 359 Unit ID CCC Volume 2.48

Column Cap for Conduit


Dimensions 6.5 in. x 26 in. x 26 in.

Page 4

Free Standing Column


6 1/2 Cap

3 6

Foundation Soil Sub-cut as required and replace with suitable compacted structural fill to achieve required bearing capacity. Freeze/Thaw If placed in an area that is susceptible to freeze and thaw cycles and the corresponding heaving of soils, excavate to a depth beyond which frost will occur and fill with concrete and/or a non-frost susceptible material such as clean crushed stone. Maximum Height Assuming the column is to be built without reinforcing rebar in the cores or other tie downs, the maximum height would be dependent upon the wind load and/or pedestrian point load to be applied to the column. The addition of rebar and grout to the column core in combination with additional embedment will allow for additional height. Construction If no rebar and grout is added to the column core, then it is recommended that a premium construction grade concrete adhesive be applied between each Column Block and also the Cap.

Page 5

Column Block with Fence

Total rail height as shown approximately 24

Total rail height as shown approximately 40 Foundation Soil Sub-cut as required and replace with suitable compacted structural fill to achieve required bearing capacity. Freeze/Thaw If placed in an area that is susceptible to freeze and thaw cycles and the corresponding heaving of soils, excavate to a depth beyond which frost will occur and fill with concrete and/or a non-frost susceptible material such as clean crushed stone.

Page 6

Column Block with Fence Rails

Column Cap

Column Block for Fence Rail - End

ReCon Half Top Block (Left Step Down)

ReCon Top Block

ReCon Half Top Block (Right Step Down)

Size of Fence Rail Opening


2 1/2

Rail: Wood, Concrete or Plastic 2 1/2 max width 4 to 8 height 86 or 66 typical length (Results in opening between Columns being 8 or 6)

5 3 1/4 Page 7

Column Block with Gate

Rails Optional

Freestanding Fence Block Optional

Foundation Soil Sub-cut as required and replace with suitable compacted structural fill to achieve required bearing capacity. Freeze/Thaw If placed in an area that is susceptible to freeze and thaw cycles and the corresponding heaving of soils, excavate to a depth beyond which frost will occur and fill with concrete and/or a non-frost susceptible material such as clean crushed stone.

Page 8

ReCon Wall Systems, Inc.


7600 West 27th Street Suite 229 St. Louis Park, MN 55426 (952) 922-0027 (952) 922-0028 (Fax Line) sales@reconwalls.com www.reconwalls.com