fLoWSIc100 flare Gas massflow measuring device

Gas Mass Flow Measurement for Flare Gas Applications

P r o d u c t I n f o r m at I o n

FLOWSIC100 Flare The reliable mass flow measurement for flare and vent gas applications

a r e a S O F a P P L I C aT I O N CO2 emission monitoring for compliance with government regulations Valve leakage detection and gas identification Optimization of steam usage in flare gas systems Gas wastage reduction Accurate mass balance calculations and process optimization

FLOWSIC100 eX-S Cross-duct high speed version (patent pending) 90 nozzle installation Retractable under process conditions Hermetically sealed stainless steel and titanium probes ATEX, IECEx and CSA approved for use in explosive hazardous areas

FLOWSIC100 eX/eX-re Cross-duct high speed version for large ducts and signal damping gases (patent pending) Retractable under process conditions Hermetically sealed stainless steel and titanium probes ATEX, IECEx and CSA approved for use in explosive hazardous areas

FLOWSIC100 eX-Pr High speed probe version (patent pending) Single flange installation Retractable under process conditions Hermetically sealed titanium probe ATEX, IECEx and CSA approved for use in explosive hazardous areas

K e Y F e aT U r e S Innovative high speed sensor design operation under very high gas velocities High resolution resulting in accurate measurement near to zero flow readings Field repeatable check procedure of factory zero flow test. Remote installation of control unit up to 1,000 m (serial interconnection) Single nozzle installation using probe version FLOWSIC100 EX-PR Improved accuracy spool piece solution Assured and reliable device function automatic self-diagnosis by integrated check cycle Single path and multi path configuration (1-, 2path, 3 x 1 path)
2 FLOWSIC100 FL are | SICK 2012-06 Subject to change without notice

FLOWSIC100 EX-S retractable (measuring position)

FLOWSIC100 EX-PR Probe version

Product deScrIPtIon The FLOWSIC100 Flare standard version contains two FLSE100 sender/receiver units (SR units) and a MCUP control unit (process version). The MCUP is used for signal inputs/outputs, determining reference values (standardization) as well as calculating molecular weight, mass flow or storage of gas volume. Optionally the MCUP is applicable in hazardous areas. The SOPAS software provides access to all parameters and contains graphical display of measured values, trend curves and stores all parameter changes and measurement events in an integrated log book. Installation of the sender/receiver units Cross-duct installation: two sender/receiver units are mounted on both sides of a duct rectangular to the gas flow direction (type FLSE100 EX-S). One-side installation: Only one single sender/receiver unit (probe version) is mounted at a specific angle to the gas flow. Both ultrasonic transducers are installed on the probe with a fixed measuring path. No specific alignment between ultrasonic transducers needed. unIQue HIGH SPeed SenSor d e S I G n ( P at e n t P e n d I n G ) For the FLOWSIC100 Flare an innovative sensor design was developed. The ultrasonic transducer is embedded in a flow optimized sensor shape special qualified for high speed gas flow conditions. The unique design reduces flow noise and signal drift to a minimum and enables stable and reliable measurement results at very high gas velocities. A optimized 2-stage signal algorithm ensures best signal processing under low flow as well as and under high flow conditions. Optional components MCUP control unit for use in Ex zone 1 + 2 (ATEX certification) and Cl I, Div2/Zone 2 Spool piece version also complete with p and T transmitters
MCUP control unit (process version)

S t atus:

Measur

ing

POWER

FAILURE

MAINTENANCE REQUEST

Statu s

Ac k

M en u

SR unit FLSE100-EXS

Cable length: up to 1,000 m

Flow direction a

Gas duct Perpendicular nozzle installation SR unit FLSE100EXS Hazardous area Safe area

Turbulences, signal disturbed

Undisturbed, constant signal dispersion, no turbulences

Embedded ultrasonic transducer

Conventional sensor

High speed sensor


SIcK | fLoWSIc100 fL are 3

2012-06 Subject to change without notice

fLoWSIc100 flare

Gas massflow measuring device

8011249/2012-06 Printed in Germany Subject to change without notice.

Technical Data Version Measuring parameter Measuring principle Measuring values Measuring range 1) Accuracy
2) 3)

fLoWSIc100 flare eX-S eX/eX-re eX-Pr

Ultrasonic transit time measurement method Mass flow, standard and actual volumetric flow, molecular weight, totalized standard volume and mass, gas velocity, gas temperature, speed of sound 0.03 up to 120 m/s
4)

0.03 up to 90 m/s

1-path measurement: 1.5 ... 5.0 %/0.5 % ; 2-path measurement: 1.0 ... 3.0 %/0.5 %4) < 2 % of measured value, 2 ... 120 kg/kmol 1-path measurement: 2.5 ... 5 % of meas. value; 2-path measurement: 2 ... 4 % of meas. value 0.001 m/s 0.2 % at 10 m/s Up to 4000 : 1 0.1 ... 0.6 m ( 4 ... 24 in) 0.2 ... 1.8 m (8 ... 72 in) 0.3 ... 1.8 m (12 ... 72 in)
5)

Accuracy of molecular weight 5) Accuracy of mass flow Resolution Repeatability Rangeability Inner duct diameter (pipe size) Measurement conditions Gas temperature

Standard range: 70 ... 180 C (95 ... 356 F) + High temperature range zone 1: 70 ... 280 C (95 ... 535 F) + zone 2: 70 ... 260 C (95 ... 500 F) + Low temperature range: 196 ... 100 C (325 ... 210 F) + 0.5 16 barg; 20 barg max. on request Sender/receiver units: 40 ... +70 C (40 ... 158 F); Optional: 50 ... +70 C (58 ... 158 F) MCUP control unit: 40 ... +60 C (40 ... 140 F) SR unit, zone 1 ATEX II 1/2G Ex d [ia] IIC T4 ATEX II 1/2G Ex de [ia] IIC T4 IECEx Ex d [ia] IIC T4 CSA CI I, Div1 group B, C, D CSA CI I, Div2 group A, B, C, D CSA CI I, zone1/zone2 IIC T4 Option: Temp. class T6 ATEX II 3G Ex nA II T4 CSA: IP65, enclosure type 4 ATEX II 2 G Ex d IIC T4 ATEX II 1/2 G Ex de IIC T4 IECEx Ex d IIC T4 CSA CI I, Div1 group B, C, D CSA CI I, Div2 group A, B, C, D CSA CI I, zone1/zone2 IIC T4 Option: Temp. class T6 ATEX II 1/2 G Ex d [ia] IIC T4 ATEX II 1/2 G Ex de [ia] IIC T4 IECEx Ex d [ia] IIC T4 CSA CI I, Div1 group B, C, D CSA CI I, Div2 group A, B, C, D CSA CI I, zone1/zone2 IIC T4 Option: Temp. class T6

Pressure range Ambient conditions Temperature range Approval Ex-certification

SR unit, zone 2

MCUP, zone 1 ATEX II 2 G Ex de IIC T6 MCUP, zone 2 ATEX II 3 G Ex nA II T4; CSA CI I, Div2; CI I, zone2 Protection class SR unit Control unit MCUP Analog output Analog inputs Digital outputs Digital inputs Interfaces Bus protocol (option) Zone 1: IP 65/67; zone 2: IP 65 CSA: IP65, enclosure type 4 Inputs, outputs, controls via MCUP control unit (process version)

CSA: IP65/67, encl. type 6

Zone 1: IP66; Zone 2, Div2: IP66, enclosure type 4; Non-ex: IP66, IP20 (19" version) 1 output active: 0/2/4 22 mA, max. load 500 6), according to NAMUR NE43 2 inputs: 0 ... 20 mA 6) Pulse/frequency output (opt. module); 5 outputs Status signals: operation/malfunction, maintenance, check cycle, limit value, maint. request 6) 2 inputs for connection of floating contacts 6) USB RS-232/-485 (RS-485 at ex-protected MCUP) MODBUS via RS-485 PROFIBUS DP via RS-485 TCP/IP via Ethernet
4) 5)

RS-485 via optional interface module Ethernet via optional interface module HARTBUS Foundation Fieldbus

Depending on process conditions For fully developed flow profile 3) Of reading, at range 0.3 up to max. value of meas. range Of reading, at range >1 m/s up to last value of cal. range (flow cal. devices)
1) 2)

Flow calibrated Hydrocarbons 6) Option: additional inputs/outputs when using I/O modules