Nivel Variable Voltage/Variable Watt Electronic Board User Guide

Important Note: Before Start Using, carefully read this Guide The device is intended for use in battery modes of electronic cigarettes to ensure stability and maximum disclosure of taste and the amount of steam according to personal preferences of the user and used atomizers. Product Features: Supply Voltage - 3,2v - 4,2v (one Li-battery) Output Voltage Range - 3,0v 6,0v Maximum Output Supported - 15w Minimum Atomizer Resistance Supported - 1,0 ohms Indication - Two-Digit Seven-Segment display and an external LED. When using the board, equipped with additional protection functions against reverse power indication by optional LED Management - External Button Voltage Stabilization Mode - Yes, the menu is selected by the user Voltage Selection Step - 0,1v Power Stabilization Node - Yes, the menu is selected by the user Power Selection Step - 0,2w in the range 3,0w - 10,0w, 0,5w in the range of 10,0w 15,0w Protection against unauthorized inclusion - Yes, On/Off, three short bursts. Low battery - Yes, Four Gradations of the battery condition. Ability to change the brightness of the main display - Yes, from the menu, you have five grades. Timer operating time heating mode - Yes, accumulating to 99ch. 59 minutes, reset the timer from the menu Ohmmeter - Yes, in the menu Limiting the time of heating at a constant touch of a button in the operating mode - Yes, the heat - 15 seconds. When you press the button for more than 30 seconds, the device goes into standby mode Protection against overheating of the power components - Yes, 60 C, with the indication Short circuit protection on output - Yes, with the indication Blocking of the cliff at the heater atomizer - Yes, with indication Lock work if you can not maintain the specified voltage, or power - Yes, with the indication Protection against reverse polarity of power supply - Optional, with an additional indication of tripping the LED

Version 1.5

Page 1 of 5

Nivel Variable Voltage/Variable Watt Electronic Board

User Guide

Description of the algorithm works: The device is controlled by an external button (not included). Management is the required number of clicks with a frequency of not less than once per second. In the process of pressing the on-screen indicator displays the letter of the regime, which corresponds to a given amount of clicks. To enter you must click on the indicator until you see the designation desired mode and then, if for one second did not happen the next push, the device switches to the selected function.

Sign

means there is no function corresponding to a given number of taps.

There are four basic device statuses: Standby mode - designed for the transport or short-term storage of your battery mode. In standby mode, pressing the control button does not cause heating atomizer. From standby or perhaps go to the operating mode or menu mode. Operating mode - the mode in which pressing the control button causes the generation of the output voltage with user defined parameters. The transition from standby to work, or vice versa, produced three short clicks.

When entering the operational mode, the display shows

and further stabilization of the

selected mode or (Power voltage U or P) and set the value of stabilization. External LED flashes at the same time three times. In active mode, by pressing the button, an external LED turns on and the display shows the battery status in the form of a horizontal rectangle segments rectangle from left to right. . In the discharge extinguished

When you exit the mode into standby, the display shows achievements .

, And after the timer displays

The values of the timer operating time are displayed in two consecutive screens, where the first screen of the decimal point in the second digit indicates the hour, and the second screen (without the decimal point) - the minute.

Example:

>

>

mean operating time of timer 2 hours 10 minutes.

Mode menu - service mode, the entrance to which is made from standby necessary (6-12) the number of clicks a command button. In this case, the function value corresponding to a given number of taps on the screen display in the form of an alphabetic cipher (see below). If you are in service mode, the user presses the button for 4 seconds, then the device goes into standby mode with memory setting selected.

Version 1.5

Page 2 of 5

Nivel Variable Voltage/Variable Watt Electronic Board

User Guide

6 clicks - go to the regime of voltage stabilization. Appears on the display (Set U), then displays the last set value voltage. When you click on, the voltage begins to rise to the upper limit of the range, and then dropped down on top of the range, and so the circle. Thus, the choice is the desired value by briefly pressing the button, at which the value is changed by one step. When you exit the setup menu parameters stabilize voltage, the device switches to the voltage regulation. That is, when you turn the device will be in the regime of voltage stabilization that the use of atomizers with different resistance will lead to different power output of atomizers.

7 clicks - mode power stabilization. Appears on the display (Set P), specifying the fully stabilized power is similar to specifying the values of the voltage regulation described in the preceding paragraph. Step value changes from 3 to 10 W - 0.2 W from 10 to 15W - 0.5W. In this case, with values above 10 watts of power a decimal point of the second level corresponds to 0.5 watts. That is, for example, scale length should read 12.5 Tues. In the power stabilization device supports an installed capacity regardless of the resistance used atomizers, which allows "hot" replacement atomizer without appreciable change in the taste of steam. 8 clicks - reset the timer mode. When you enter the mode on the display alternately displays the letter , And after status value of the timer. Current timer value is indicated by two consecutive screens, where the first screen (with decimal point in the second digit) denotes the hours and the second screen (without the decimal point) - minutes.

Example:

>

>

mean operating time of timer 2 hours 10 minutes. Pressing

the button while the timer status display gives rise to a inscriptions (Cleaning), and the next push will result in resetting the timer. If you refuse to confirm, the device goes into standby mode without resetting the timer. 9 key - the selection mode the main display brightness. When you enter the mode is displayed (Set display). Each press of a button, change the display brightness, while the display shows the numbers from 1 to 5 with a brightness corresponding to the selected value. 10 clicks - a mode selection device indicate the status of work. In this menu the selected display unit that will work when you click into work mode. When you enter the mode is displayed (Set LED). Each press of the button turns on / off the device display. The following combination: the + LED display, only the display, only the LED button, and all off. Note: Turning off display unit will not work when you click on Mode, when working on a menu or when you change modes all the display unit will work in spite of whether you want to work in this menu. 11 clicks - the display mode of resistance atomizer. When you log in on the display mode is displayed (R Atomizer), and after - the measured resistance atomizer.

Version 1.5

Page 3 of 5

Nivel Variable Voltage/Variable Watt Electronic Board

User Guide

12 clicks - a function to limit the number of puffs. This feature helps users to restrict ourselves to the consumption of harmful substances entering the body in the process of evaporation, by limiting the number of forced clicks and lock operation between groups of stroke. When you enter the setup menu of this mode, the screen displays (Over Limit), then the user is prompted to select the desired number of clicks in the group (number of puffs per cigarette break) from 5 to 40 clicks in increments of 5 taps. If you select oF protection function is not active. Algorithm: the choice of any value other than the number of puffs values oF, the device begins to count the number of puffs. In this case, the tightening is pressing duration of not less than one second. If the number of clicks has reached the user selected value, the device does not heat the atomizer for 30 min. But here, if the clicks did not reach the upper threshold selected by the user and between the pressures has been more than five minutes, the meter will automatically reset the number of clicks to zero. When you click in the lock indicator appears on the screen in minutes to unlock the device. and then - the remaining time

Example:

>

means to unlock the device, the remaining 29 minutes.

13 clicks - show the version number of the microcontroller. When you enter the mode the screen displays (Firmware), and then displays the version number.

The display mode of emergencies. If you have an emergency situation which led to the inability of the device - the heating is turned off, an external LED flashes at 0.5 Hz (regardless of whether you are allowed to work in the menu or not), and the phone displays an error code. The device goes into standby mode.

Version 1.5

Page 4 of 5

Nivel Variable Voltage/Variable Watt Electronic Board Error codes:

User Guide

- Low resistance to the atomizer. May short circuit, replace the atomizer.

- Impossible to maintain a fixed voltage value, reduce stress. The error is possible using atomizers with low resistance and high value of the stabilized voltage.

- Impossible to maintain a fixed value of power. The error appears when the selected value of the power at a given resistance of the atomizer does not fit into the device supports 3,0v 6,0v, 3,0w 15w, this error can occur if too large or too small for the chosen values of the power resistor atomizer. Decrease or increase capacity. E3 error can also occur in the regime of voltage stabilization, if the resistance of the atomizer is too large, for example, the breaking of the atomizer atomizer or no contact with the board of explosives.

- Fired thermal protection board. Do not use the device for some time.

- High internal resistance of the power supply. E5 error occurs when the battery voltage with no load can not consider it discharged, but, under the load voltage drops to a critical value. Try to reduce the value of stabilized power or voltage. E5 error may also occur in cases of high transition resistance contacts on the battery. Remove the oxide film and contamination of contact surfaces. Note: Often there was an error E5, usually evidenced by the low quality of used batteries, or the end of their life. Protection against reverse polarity power supply board (optional) - if your motherboard is equipped with this feature, when activated protection, this will signal the LED to the left of the indicator Warnings Do not be guaranteed stable operation at high values of power and voltage using the batteries with built-in. Do not use the device for other purposes! Forbidden to feed the device voltage exceeds the range specified in the characteristics of the device! You may not use a load of anything other than a resistive load! Forbidden to apply voltage to the output device! Before the first, after installation, power supply again carefully check compliance with the requirements of the scheme you mounted installation instructions. Failure to comply may not only lead to failure of the device, but a fire or explosion even your lithium battery.