EVENT Intra-frequency measurements Event 1a Event 1b Event 1c Event 1d Event 1e Event 1f Event 1g Event 1h Event 1i Event 1j Inter-frequency measurements

Event 2a Event 2b Event 2c Event 2d Event 2e Event 2f Inter-RAT measurements Event 3a Event 3b Event 3c Event 3d event 4A event 4B event 5A UE internal measurements event 6A event 6B event 6C event 6D event 6E event 6F (FDD) event 6F (1.28 Mcps TDD) event 6G Event 7a Event 7b Event 7c Event 7d Event 7d

DESCRIPTION A Primary CPICH enters the Reporting Range (FDD only). A Primary CPICH leaves the Reporting Range (FDD only). A Non-active Primary CPICH becomes better than an active Primary CPICH (FDD only). Change of best cell (FDD only). A Primary CPICH becomes better than an absolute threshold (FDD only). A Primary CPICH becomes worse than an absolute threshold (FDD only). Change of best cell in TDD. Timeslot ISCP below a certain threshold (TDD only). Timeslot ISCP above a certain threshold (TDD only). A Non-active E-DCH but active DCH Primary CPICH becomes better than an active E-DCH Primary CPICH (FDD only). Change of best frequency. The estimated quality of the currently used frequency is below a certain threshold and the estimated quality of a non-used frequency is above a certain threshold. The estimated quality of a non-used frequency is above a certain threshold The estimated quality of the currently used frequency is below a certain threshold The estimated quality of a non-used frequency is below a certain threshold The estimated quality of the currently used frequency is above a certain threshold The estimated quality of the currently used UTRAN frequency is below a certain threshold and the estimated quality of the other system is above a certain threshold. The estimated quality of other system is below a certain threshold The estimated quality of other system is above a certain threshold Change of best cell in other system Transport Channel Traffic Volume becomes larger than an absolute threshold Transport Channel Traffic Volume becomes smaller than an absolute threshold A predefined number of bad CRCs is exceeded The UE Tx power becomes larger than an absolute threshold The UE Tx power becomes less than an absolute threshold The UE Tx power reaches its minimum value The UE Tx power reaches its maximum value The UE RSSI reaches the UE's dynamic receiver range The UE Rx-Tx time difference for a RL included in the active set becomes larger than an absolute threshold The time difference indicated by TADV becomes larger than an absolute threshold The UE Rx-Tx time difference for a RL included in the active set becomes less than an absolute threshold The UE position changes more than an absolute threshold SFN-SFN measurement changes more than an absolute threshold GPS time and SFN time have drifted apart more than an absolute threshold GANSS time and SFN time have drifted apart more than an absolute threshold GANSS time and SFN time have drifted apart more than an absolute threshold

EVENT
Intra-frequency measurements Reporting event 1A Reporting event 1B Reporting event 1C Reporting event 1D Reporting event 1E Reporting event 1F Reporting event 1G Reporting event 1H Reporting event 1I Inter-frequency measurements Event 2a Event 2b frequency is above a certain threshold Event 2c Event 2d Event 2e Event 2f Inter-RAT measurements Event 3a Event 3b Event 3c Event 3d UE internal measurements Reporting event 6A Reporting event 6B Reporting event 6C Reporting event 6D Reporting event 6E Reporting event 6F Reporting event 6G Reporting event 6G

DESCRIPTION
A Primary CPICH enters the reporting range A primary CPICH leaves the reporting range A non-active primary CPICH becomes better than an active primary CPICH Change of best cell A Primary CPICH becomes better than an absolute threshold A Primary CPICH becomes worse than an absolute threshold Intra-frequency reporting events for TDD Change of best cell (TDD) Timeslot ISCP below a certain threshold (TDD) Timeslot ISCP above a certain threshold (TDD) Change of best frequency. The estimated quality of the currently used frequency is below a certain threshold and the estimated quality of a non-used The estimated quality of a non-used frequency is above a certain threshold The estimated quality of the currently used frequency is below a certain threshold The estimated quality of a non-used frequency is below a certain threshold The estimated quality of the currently used frequency is above a certain threshold The estimated quality of the currently used UTRAN frequency is below a certain threshold and the estimated quality of the other system is above a certain threshold The estimated quality of other system is below a certain threshold The estimated quality of other system is above a certain threshold Change of best cell in other system The UE Tx power becomes larger than an absolute threshold The UE Tx power becomes less than an absolute threshold The UE Tx power reaches its minimum value The UE Tx power reaches its maximum value The UE RSSI reaches the UE's dynamic receiver range The UE Rx-Tx time difference for a RL included in the active set becomes larger than an absolute threshold The UE Rx-Tx time difference for a RL included in the active set becomes less than an absolute threshold The UE Rx-Tx time difference for a RL included in the active set becomes less than an absolute threshold