You are on page 1of 5

DATA SHEET FOR CONSISTENCY TRANSMITTER

Project Servalakshmi Paper Pvt Ltd


Section DIP
Doc. No. Sheet No. 1(2) Ref Drawing-STOD044791
Rev. 0 Date 26/4/2008
1 Tag No. QT1213 QT1303 QT1402 Qt1906
2 Qty 1 1 1 1
Dump tower feed Coarse Main flotation Dispersing feed
3 Service
consistency screening feed feed consistency consistency
5 Manufacturer By vendor
6 Model No. By vendor
7 Function To measure the consistency
8 Pipe Line No. 1002 1011 1041 1135
General

9 Pipe Line Size in DN 350 350 350 150


10 Pipe Line Materials SS36 SS36 SS36 SS36
11 Case Die cast aluminum
12 Mounting Direct on line mounting
13 Electrical Area Classification NA
14 Enclosure Class IP67
15 Intrinsically Safe NA
16 Power Supply 220V AC
17 Cable Entry ½''NPT
18 Accuracy 0.075% of full scale reading
19 Repeatability 0.08%

20 Type Blade type / Microprocessor based smart, HART protocol


Transmitter

21 Range 2.0 – 5.0%CS 2.0 – 6.0%CS 2.0 – 5.0%CS 5.0 – 15.0%CS


22 Communication protocal Foundation field bus
23 Local Indication Required , digital indication in engg unit
24 Enclosure Class IP67
25 Cable Entry ½''NPT(M)
26 Process Connection By vendor
27 Process Fluid PULP PULP PULP Pulp stock
28 Ink, Pitch or other Contaminations - - - -
Process Data

29 Consistency after Dilution (%CS) 3.5%CS 3.13%CS 2.5%CS 10%CS


30 Consistency before dilution(%CS) 4.5%CS 3.5%CS 2.9%CS 11.5%CS
31 Dilution Water - - - -
32 Temperature (Max) ('C) 40'C 40'c 40'c 40'C
33 pH NA NA NA NA
34 Flow Rate(l/min)) 9000 9500 11400 2083

Accessories Sampling valve , weld stud , clamp, O-rings, tag name plate

* Data to be furnished by Customer

Page 1 of 5
QT 2

DATA SHEET FOR CONSISTENCY TRANSMIT

Project
Section DIP
Doc. No. Sheet No. 2(2)
Rev. 0 Date 26/4/2008
1 Tag No. QT2003
2 Qty 1
Bleaching tower
3 Service
discharge
5 Manufacturer By vendor
6 Model No. By vendor
7 Function To measure the cons
8 Pipe Line No. 1143
9 Pipe Line Size in DN 300
General

10 Pipe Line Materials SS316


11 Case Die cast aluminum
12 Mounting Direct on line moun
13 Electrical Area Classification NA
14 Enclosure Class IP67
15 Intrinsically Safe NA
16 Power Supply 220V AC
17 Cable Entry ½''NPT(M)
18 Accuracy 0.075% of FSR
19 Repeatability 0.08%

20 Type Blade type / Microprocessor based s


21 Range 2.0 – 5.0%cs
Transmitter

22 Communication protocol Foundation field b


23 Local Indication REQUIORED , DIGITAL INDICA
24 Enclosure Class IP67
25 Cable Entry ½''NPT(F)
26 Process Connection By vendor
27 Process Fluid Pulp
28 Ink, Pitch or other Contaminations -
Process Data

29 Consistency after Dilution (%CS) 3.5%CS


30 Consistency before dilution(%CS) 4.5%CS
31 Dilution Water -
32 Temperature (Max) ('C) 50'C
33 pH NA
34 Flow Rate(l/min)) 6385

Accessories Sampling valve , weld stud , clamp, O

* Data to be furnished by Customer

Page 2
QT 2
* Data to be furnished by Customer

Page 3
QT 2

ET FOR CONSISTENCY TRANSMITTER

Servalakshmi Paper Pvt Ltd


DIP
2(2) Ref Drawing-STOD044791
26/4/2008
QT2108 QT2406
1 1
Post flotation Storage tower
feed feed consistency
By vendor
By vendor
To measure the consistency
1147 1178
300 150
SS316 SS316
Die cast aluminum
Direct on line mounting
NA
IP67
NA
220V AC
½''NPT(M)
0.075% of FSR
0.08%

Blade type / Microprocessor based smart, HART protocol


2.0 – 5.0%cs 5.0 – 15.0%cs
Foundation field bus
REQUIORED , DIGITAL INDICATON in engg unit
IP67
½''NPT(F)
By vendor
Pulp PULP
- -
3%CS 10%CS
3.5%CS 11.5%CS
- -
50'C 40'c
NA NA
9500 2083

Sampling valve , weld stud , clamp, O-rings, tag name plate