POWER SUPPLY (Frequency) REQUIRED CAPACITY CHILLER MAKE CHILLER NOMINAL CAPACITY NO. OF CHILLERS 2 X 300 TONS PETRA 289 Tons 2 289 X 2 = 578 TONS Saudi Arabia CARRIER 292 Tons 2 292 X 2 = 584 TONS France 30XA1102A 134A 1,390,000 134A 1,770,000 134A 1,085,000 50 Hz 1 X 500 TONS PETRA 428 Tons 1 428 X 1 = 428 TONS Saudi Arabia CARRIER 421 Tons 1 421 X 1 = 421 TONS France 30XA1702A 134A 1,250,000 2 X 300 TONS PETRA 293 Tons 2 293 x 2 = 586 TONS Saudi Arabia APSa 300 134A 1,000,000 CARRIER 294 Tons 2 294 x 2 = 588 TONS USA 30XA 325 134A 1,484,000 60 Hz 1 X 500 TONS PETRA 444 Tons 1 445 x 1 = 445 TONS Saudi Arabia APSa 500 134A 800,000 CARRIER 438 Tons 1 438 x 1 = 438 TONS USA 30XA500 134A 1,085,000
MADE IN CHILLER MODEL NO REFRIGERANT CHILLER PRICE (SAR) PRICE FOR PIPING, PIPING ACCESSORIES, ELECTRICAL AND RELATED WORKS (SAR) TOTAL PRICE. VALIDITY OF OFFER DELIVERY WARRANTY
980,000
980,000
890,000
890,000
980,000
980,000
890,000
890,000
PROCESS CHILLER OFFER (2Nos X 300 Tons @ 380/3/50Hz) Item # Description AIR COOLED CHILLER Make : PETRA ( Petra International) Model No : Nominal Capacity : 300 TONS Power Supply : 380/3/50Hz General Specifications And other features : Semi-hermetic Screw compressors. Rubber pad Isolators. Copper tubes with Aluminum fins condenser. Insulated cooler with removable head. Designed to meet harsh ambient conditions and suitable for outdoor installtions. Microprocessor controlled performance. Phase protection for the unit. Thermal and overload protection for Compressors and Motors Pressure safety swithes and other standard refrigerantion circuit devices. CHILLED WATER PIPING & ACCESSORIES. Above ground and under ground Chilled water piping and fittings connecting the chiller to the inlet ports with black steel pipe including excavation of ground and covering up thereafterand including all necessary fitting (Elbow, Tee, Reducer ), valves , Automatic air vents, hanger, support as per drawings and specifications. ( Drawings to be submitted for approval prior to commencing the work at site.) 80 mm dia 100 mm dia 125 mm dia 200 mm dia PAGE TOTAL
M L/s 744,000 744,000
Unit NOS
Qty 2
1.0.0 1.1.0 1.2.0 1.3.0 1.4.0 1.5.0 1.5.1 1.5.2 1.5.3 1.5.4 1.5.5 1.5.6 1.5.7 1.5.8 1.5.9
2.0.0 2.1.0
M M M M
2,134,000
--
Option-01: 2 of 25
September 2012
PROCESS CHILLER OFFER (2Nos X 300 Tons @ 380/3/50Hz) Item # Description 50mm thick premoulded fibreglass pipe sectional insulation for chilled water pipe having 64 Kg/m density as per drawings and specifications 80 mm dia 100 mm dia 125 mm dia 200 mm dia Double regulating valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia Isolating Valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia ELECTRICAL WORKS. Chiller Starter Chiller control panel Cabling works Includes all electrical and control cabling works between chiller and the available power supply point at site. TESTING AND COMMISSIONING. Testing and commissioning of the chiller plant system including cartage and unloading of the chillers.Operation and maintenance manual for the designed system complete with all equipment, components, accessories, fittings fixings, connections, cables, conduits, etc. as required and specified.
M M M M No. No. No. No. L/s L/s L/s L/s L/s L/s L/s L/s
Unit
Qty
Unit Price
2.2.0
2.2.3 2.2.4 2.2.5 2.2.6 2.3.0 2.3.1 2.3.2 2.3.3 2.3.4 2.4.0 2.4.1 2.4.2 2.4.3 2.4.4 3.0.0 3.1.0 3.2.0 3.3.0
4.0.0 4.1.0
Lot.
55,000
55,000
5.0.0
EXCLUSIONS. 5.1.0 Any Item not specified above. 5.2.0 Mounting structure (Steel or concrete) for the chiller.
PAGE TOTAL 236,000
--
Option-01: 3 of 25
September 2012
Description
Unit
Qty
Unit Price
Any re-routing of existing infrastructure encountered during excavation to lay pipes and cables. Any cabling work beyond 10 linear meters. The power supply to the chiller is expected to be located within a radius of 10 Meters.
5.4.0
GRAND TOTAL
2,370,000
--
Option-01: 4 of 25
September 2012
PROCESS CHILLER OFFER (2Nos X 300 Tons @ 380/3/50Hz) Item # Description AIR COOLED CHILLER Make : CARRIER Model No : 30XA1102A Nominal Capacity : 300 TONS Power Supply : 380/3/50Hz General Specifications And other features : Semi-hermetic Screw compressors. Rubber pad Isolators. Copper tubes with Aluminum fins condenser. Insulated cooler with removable head. Designed to meet harsh ambient conditions and suitable for outdoor installtions. Microprocessor controlled performance. Phase protection for the unit. Thermal and overload protection for Compressors and Motors Pressure safety swithes and other standard refrigerantion circuit devices. CHILLED WATER PIPING & ACCESSORIES. Above ground and under ground Chilled water piping and fittings connecting the chiller to the inlet ports with black steel pipe including excavation of ground and covering up thereafterand including all necessary fitting (Elbow, Tee, Reducer ), valves , Automatic air vents, hanger, support as per drawings and specifications. ( Drawings to be submitted for approval prior to commencing the work at site.) 80 mm dia 100 mm dia 125 mm dia 200 mm dia PAGE TOTAL
M L/s 744,000 744,000
Unit NOS
Qty 2
1.0.0 1.1.0 1.2.0 1.3.0 1.4.0 1.5.0 1.5.1 1.5.2 1.5.3 1.5.4 1.5.5 1.5.6 1.5.7 1.5.8 1.5.9
2.0.0 2.1.0
M M M M
2,514,000
--
Option-02: 5 of 25
September 2012
PROCESS CHILLER OFFER (2Nos X 300 Tons @ 380/3/50Hz) Item # Description 50mm thick premoulded fibreglass pipe sectional insulation for chilled water pipe having 64 Kg/m density as per drawings and specifications 80 mm dia 100 mm dia 125 mm dia 200 mm dia Double regulating valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia Isolating Valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia ELECTRICAL WORKS. Chiller Starter Chiller control panel Cabling works Includes all electrical and control cabling works between chiller and the available power supply point at site. TESTING AND COMMISSIONING. Testing and commissioning of the chiller plant system including cartage and unloading of the chillers.Operation and maintenance manual for the designed system complete with all equipment, components, accessories, fittings fixings, connections, cables, conduits, etc. as required and specified.
M M M M No. No. No. No. L/s L/s L/s L/s L/s L/s L/s L/s
Unit
Qty
Unit Price
2.2.0
2.2.3 2.2.4 2.2.5 2.2.6 2.3.0 2.3.1 2.3.2 2.3.3 2.3.4 2.4.0 2.4.1 2.4.2 2.4.3 2.4.4 3.0.0 3.1.0 3.2.0 3.3.0
4.0.0 4.1.0
Lot.
55,000
55,000
5.0.0
EXCLUSIONS. 5.1.0 Any Item not specified above. 5.2.0 Mounting structure (Steel or concrete) for the chiller.
PAGE TOTAL 236,000
--
Option-02: 6 of 25
September 2012
Description
Unit
Qty
Unit Price
Any re-routing of existing infrastructure encountered during excavation to lay pipes and cables. Any cabling work beyond 10 linear meters. The power supply to the chiller is expected to be located within a radius of 10 Meters.
5.4.0
GRAND TOTAL
2,750,000
--
Option-02: 7 of 25
September 2012
PROCESS CHILLER OFFER (1Nos X 500 Tons @ 380/3/50Hz) Item # Description AIR COOLED CHILLER Make : PETRA (Petra International) Model No : Nominal Capacity : 500 TONS Power Supply : 380/3/50Hz General Specifications And other features : Semi-hermetic Screw compressors. Rubber pad Isolators. Copper tubes with Aluminum fins condenser. Insulated cooler with removable head. Designed to meet harsh ambient conditions and suitable for outdoor installtions. Microprocessor controlled performance. Phase protection for the unit. Thermal and overload protection for Compressors and Motors Pressure safety swithes and other standard refrigerantion circuit devices. CHILLED WATER PIPING & ACCESSORIES. Above ground and under ground Chilled water piping and fittings connecting the chiller to the inlet ports with black steel pipe including excavation of ground and covering up thereafterand including all necessary fitting (Elbow, Tee, Reducer ), valves , Automatic air vents, hanger, support as per drawings and specifications. ( Drawings to be submitted for approval prior to commencing the work at site.) 80 mm dia 100 mm dia 125 mm dia 200 mm dia PAGE TOTAL
M L/s 695,000 695,000
Unit NOS
Qty 1
1.0.0 1.1.0 1.2.0 1.3.0 1.4.0 1.5.0 1.5.1 1.5.2 1.5.3 1.5.4 1.5.5 1.5.6 1.5.7 1.5.8 1.5.9
2.0.0 2.1.0
M M M M
1,780,000
--
Option-03: 8 of 25
September 2012
PROCESS CHILLER OFFER (1Nos X 500 Tons @ 380/3/50Hz) Item # Description 50mm thick premoulded fibreglass pipe sectional insulation for chilled water pipe having 64 Kg/m density as per drawings and specifications 80 mm dia 100 mm dia 125 mm dia 200 mm dia Double regulating valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia Isolating Valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia ELECTRICAL WORKS. Chiller Starter Chiller control panel Cabling works Includes all electrical and control cabling works between chiller and the available power supply point at site. TESTING AND COMMISSIONING. Testing and commissioning of the chiller plant system including cartage and unloading of the chillers.Operation and maintenance manual for the designed system complete with all equipment, components, accessories, fittings fixings, connections, cables, conduits, etc. as required and specified.
M M M M No. No. No. No. L/s L/s L/s L/s L/s L/s L/s L/s
Unit
Qty
Unit Price
2.2.0
2.2.3 2.2.4 2.2.5 2.2.6 2.3.0 2.3.1 2.3.2 2.3.3 2.3.4 2.4.0 2.4.1 2.4.2 2.4.3 2.4.4 3.0.0 3.1.0 3.2.0 3.3.0
4.0.0 4.1.0
Lot.
40,000
40,000
5.0.0
EXCLUSIONS. 5.1.0 Any Item not specified above. 5.2.0 Mounting structure (Steel or concrete) for the chiller.
PAGE TOTAL 195,000
--
Option-03: 9 of 25
September 2012
Description
Unit
Qty
Unit Price
Any re-routing of existing infrastructure encountered during excavation to lay pipes and cables. Any cabling work beyond 10 linear meters. The power supply to the chiller is expected to be located within a radius of 10 Meters.
5.4.0
GRAND TOTAL
1,975,000
--
Option-03: 10 of 25
September 2012
PROCESS CHILLER OFFER (1Nos X 500 Tons @ 380/3/50Hz) Item # Description AIR COOLED CHILLER Make : CARRIER Model No : 30XA1702A Nominal Capacity : 500 TONS Power Supply : 380/3/50Hz General Specifications And other features : Semi-hermetic Screw compressors. Rubber pad Isolators. Copper tubes with Aluminum fins condenser. Insulated cooler with removable head. Designed to meet harsh ambient conditions and suitable for outdoor installtions. Microprocessor controlled performance. Phase protection for the unit. Thermal and overload protection for Compressors and Motors Pressure safety swithes and other standard refrigerantion circuit devices. CHILLED WATER PIPING & ACCESSORIES. Above ground and under ground Chilled water piping and fittings connecting the chiller to the inlet ports with black steel pipe including excavation of ground and covering up thereafterand including all necessary fitting (Elbow, Tee, Reducer ), valves , Automatic air vents, hanger, support as per drawings and specifications. ( Drawings to be submitted for approval prior to commencing the work at site.) 80 mm dia 100 mm dia 125 mm dia 200 mm dia PAGE TOTAL
M L/s 695,000 695,000
Unit NOS
Qty 1
1.0.0 1.1.0 1.2.0 1.3.0 1.4.0 1.5.0 1.5.1 1.5.2 1.5.3 1.5.4 1.5.5 1.5.6 1.5.7 1.5.8 1.5.9
2.0.0 2.1.0
M M M M
1,945,000
--
Option-04: 11 of 25
September 2012
PROCESS CHILLER OFFER (1Nos X 500 Tons @ 380/3/50Hz) Item # Description 50mm thick premoulded fibreglass pipe sectional insulation for chilled water pipe having 64 Kg/m density as per drawings and specifications 80 mm dia 100 mm dia 125 mm dia 200 mm dia Double regulating valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia Isolating Valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia ELECTRICAL WORKS. Chiller Starter Chiller control panel Cabling works Includes all electrical and control cabling works between chiller and the available power supply point at site. TESTING AND COMMISSIONING. Testing and commissioning of the chiller plant system including cartage and unloading of the chillers.Operation and maintenance manual for the designed system complete with all equipment, components, accessories, fittings fixings, connections, cables, conduits, etc. as required and specified.
M M M M No. No. No. No. L/s L/s L/s L/s L/s L/s L/s L/s
Unit
Qty
Unit Price
2.2.0
2.2.3 2.2.4 2.2.5 2.2.6 2.3.0 2.3.1 2.3.2 2.3.3 2.3.4 2.4.0 2.4.1 2.4.2 2.4.3 2.4.4 3.0.0 3.1.0 3.2.0 3.3.0
4.0.0 4.1.0
Lot.
40,000
40,000
5.0.0
EXCLUSIONS. 5.1.0 Any Item not specified above. 5.2.0 Mounting structure (Steel or concrete) for the chiller.
PAGE TOTAL 195,000
--
Option-04: 12 of 25
September 2012
Description
Unit
Qty
Unit Price
Any re-routing of existing infrastructure encountered during excavation to lay pipes and cables. Any cabling work beyond 10 linear meters. The power supply to the chiller is expected to be located within a radius of 10 Meters.
5.4.0
GRAND TOTAL
2,140,000
--
Option-04: 13 of 25
September 2012
PROCESS CHILLER OFFER (2Nos X 300 Tons @ 380/3/60Hz) Item # Description AIR COOLED CHILLER Make : PETRA ( Petra International) Model No : APSa300 Nominal Capacity : 300 TONS Power Supply : 380/3/60Hz General Specifications And other features : Semi-hermetic Screw compressors. Rubber pad Isolators. Copper tubes with Aluminum fins condenser. Insulated cooler with removable head. Designed to meet harsh ambient conditions and suitable for outdoor installtions. Microprocessor controlled performance. Phase protection for the unit. Thermal and overload protection for Compressors and Motors Pressure safety swithes and other standard refrigerantion circuit devices. CHILLED WATER PIPING & ACCESSORIES. Above ground and under ground Chilled water piping and fittings connecting the chiller to the inlet ports with black steel pipe including excavation of ground and covering up thereafterand including all necessary fitting (Elbow, Tee, Reducer ), valves , Automatic air vents, hanger, support as per drawings and specifications. ( Drawings to be submitted for approval prior to commencing the work at site.) 80 mm dia 100 mm dia 125 mm dia 200 mm dia PAGE TOTAL
M L/s 744,000 744,000
Unit NOS
Qty 2
1.0.0 1.1.0 1.2.0 1.3.0 1.4.0 1.5.0 1.5.1 1.5.2 1.5.3 1.5.4 1.5.5 1.5.6 1.5.7 1.5.8 1.5.9
2.0.0 2.1.0
M M M M
1,744,000
--
Option-05: 14 of 25
September 2012
PROCESS CHILLER OFFER (2Nos X 300 Tons @ 380/3/60Hz) Item # Description 50mm thick premoulded fibreglass pipe sectional insulation for chilled water pipe having 64 Kg/m density as per drawings and specifications 80 mm dia 100 mm dia 125 mm dia 200 mm dia Double regulating valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia Isolating Valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia ELECTRICAL WORKS. Chiller Starter Chiller control panel Cabling works Includes all electrical and control cabling works between chiller and the available power supply point at site. TESTING AND COMMISSIONING. Testing and commissioning of the chiller plant system including cartage and unloading of the chillers.Operation and maintenance manual for the designed system complete with all equipment, components, accessories, fittings fixings, connections, cables, conduits, etc. as required and specified.
M M M M No. No. No. No. L/s L/s L/s L/s L/s L/s L/s L/s
Unit
Qty
Unit Price
2.2.0
2.2.3 2.2.4 2.2.5 2.2.6 2.3.0 2.3.1 2.3.2 2.3.3 2.3.4 2.4.0 2.4.1 2.4.2 2.4.3 2.4.4 3.0.0 3.1.0 3.2.0 3.3.0
4.0.0 4.1.0
Lot.
55,000
55,000
5.0.0
EXCLUSIONS. 5.1.0 Any Item not specified above. 5.2.0 Mounting structure (Steel or concrete) for the chiller.
PAGE TOTAL 236,000
--
Option-05: 15 of 25
September 2012
Description
Unit
Qty
Unit Price
Any re-routing of existing infrastructure encountered during excavation to lay pipes and cables. Any cabling work beyond 10 linear meters. The power supply to the chiller is expected to be located within a radius of 10 Meters.
5.4.0
GRAND TOTAL
1,980,000
--
Option-05: 16 of 25
September 2012
PROCESS CHILLER OFFER (2Nos X 300 Tons @ 380/3/60Hz) Item # Description AIR COOLED CHILLER Make : CARRIER Model No : 30XA325 Nominal Capacity : 300 TONS Power Supply : 380/3/60Hz General Specifications And other features : Semi-hermetic Screw compressors. Rubber pad Isolators. Copper tubes with Aluminum fins condenser. Insulated cooler with removable head. Designed to meet harsh ambient conditions and suitable for outdoor installtions. Microprocessor controlled performance. Phase protection for the unit. Thermal and overload protection for Compressors and Motors Pressure safety swithes and other standard refrigerantion circuit devices. CHILLED WATER PIPING & ACCESSORIES. Above ground and under ground Chilled water piping and fittings connecting the chiller to the inlet ports with black steel pipe including excavation of ground and covering up thereafterand including all necessary fitting (Elbow, Tee, Reducer ), valves , Automatic air vents, hanger, support as per drawings and specifications. ( Drawings to be submitted for approval prior to commencing the work at site.) 80 mm dia 100 mm dia 125 mm dia 200 mm dia PAGE TOTAL
M L/s 744,000 744,000
Unit NOS
Qty 2
1.0.0 1.1.0 1.2.0 1.3.0 1.4.0 1.5.0 1.5.1 1.5.2 1.5.3 1.5.4 1.5.5 1.5.6 1.5.7 1.5.8 1.5.9
2.0.0 2.1.0
M M M M
2,228,000
--
Option-06: 17 of 25
September 2012
PROCESS CHILLER OFFER (2Nos X 300 Tons @ 380/3/60Hz) Item # Description 50mm thick premoulded fibreglass pipe sectional insulation for chilled water pipe having 64 Kg/m density as per drawings and specifications 80 mm dia 100 mm dia 125 mm dia 200 mm dia Double regulating valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia Isolating Valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia ELECTRICAL WORKS. Chiller Starter Chiller control panel Cabling works Includes all electrical and control cabling works between chiller and the available power supply point at site. TESTING AND COMMISSIONING. Testing and commissioning of the chiller plant system including cartage and unloading of the chillers.Operation and maintenance manual for the designed system complete with all equipment, components, accessories, fittings fixings, connections, cables, conduits, etc. as required and specified.
M M M M No. No. No. No. L/s L/s L/s L/s L/s L/s L/s L/s
Unit
Qty
Unit Price
2.2.0
2.2.3 2.2.4 2.2.5 2.2.6 2.3.0 2.3.1 2.3.2 2.3.3 2.3.4 2.4.0 2.4.1 2.4.2 2.4.3 2.4.4 3.0.0 3.1.0 3.2.0 3.3.0
4.0.0 4.1.0
Lot.
55,000
55,000
5.0.0
EXCLUSIONS. 5.1.0 Any Item not specified above. 5.2.0 Mounting structure (Steel or concrete) for the chiller.
PAGE TOTAL 236,000
--
Option-06: 18 of 25
September 2012
Description
Unit
Qty
Unit Price
Any re-routing of existing infrastructure encountered during excavation to lay pipes and cables. Any cabling work beyond 10 linear meters. The power supply to the chiller is expected to be located within a radius of 10 Meters.
5.4.0
GRAND TOTAL
2,464,000
--
Option-06: 19 of 25
September 2012
PROCESS CHILLER OFFER (1Nos X 500 Tons @ 380/3/60Hz) Item # Description AIR COOLED CHILLER Make : PETRA (Petra International) Model No : APSa500 Nominal Capacity : 500 TONS Power Supply : 380/3/60Hz General Specifications And other features : Semi-hermetic Screw compressors. Rubber pad Isolators. Copper tubes with Aluminum fins condenser. Insulated cooler with removable head. Designed to meet harsh ambient conditions and suitable for outdoor installtions. Microprocessor controlled performance. Phase protection for the unit. Thermal and overload protection for Compressors and Motors Pressure safety swithes and other standard refrigerantion circuit devices. CHILLED WATER PIPING & ACCESSORIES. Above ground and under ground Chilled water piping and fittings connecting the chiller to the inlet ports with black steel pipe including excavation of ground and covering up thereafterand including all necessary fitting (Elbow, Tee, Reducer ), valves , Automatic air vents, hanger, support as per drawings and specifications. ( Drawings to be submitted for approval prior to commencing the work at site.) 80 mm dia 100 mm dia 125 mm dia 200 mm dia PAGE TOTAL
M L/s 695,000 695,000
Unit NOS
Qty 1
1.0.0 1.1.0 1.2.0 1.3.0 1.4.0 1.5.0 1.5.1 1.5.2 1.5.3 1.5.4 1.5.5 1.5.6 1.5.7 1.5.8 1.5.9
2.0.0 2.1.0
M M M M
1,495,000
--
Option-07: 20 of 25
September 2012
PROCESS CHILLER OFFER (1Nos X 500 Tons @ 380/3/60Hz) Item # Description 50mm thick premoulded fibreglass pipe sectional insulation for chilled water pipe having 64 Kg/m density as per drawings and specifications 80 mm dia 100 mm dia 125 mm dia 200 mm dia Double regulating valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia Isolating Valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia ELECTRICAL WORKS. Chiller Starter Chiller control panel Cabling works Includes all electrical and control cabling works between chiller and the available power supply point at site. TESTING AND COMMISSIONING. Testing and commissioning of the chiller plant system including cartage and unloading of the chillers.Operation and maintenance manual for the designed system complete with all equipment, components, accessories, fittings fixings, connections, cables, conduits, etc. as required and specified.
M M M M No. No. No. No. L/s L/s L/s L/s L/s L/s L/s L/s
Unit
Qty
Unit Price
2.2.0
2.2.3 2.2.4 2.2.5 2.2.6 2.3.0 2.3.1 2.3.2 2.3.3 2.3.4 2.4.0 2.4.1 2.4.2 2.4.3 2.4.4 3.0.0 3.1.0 3.2.0 3.3.0
4.0.0 4.1.0
Lot.
40,000
40,000
5.0.0
EXCLUSIONS. 5.1.0 Any Item not specified above. 5.2.0 Mounting structure (Steel or concrete) for the chiller.
PAGE TOTAL 195,000
--
Option-07: 21 of 25
September 2012
Description
Unit
Qty
Unit Price
Any re-routing of existing infrastructure encountered during excavation to lay pipes and cables. Any cabling work beyond 10 linear meters. The power supply to the chiller is expected to be located within a radius of 10 Meters.
5.4.0
GRAND TOTAL
1,690,000
--
Option-07: 22 of 25
September 2012
PROCESS CHILLER OFFER (1Nos X 500 Tons @ 380/3/60Hz) Item # Description AIR COOLED CHILLER Make : CARRIER Model No : 30XA500 Nominal Capacity : 500 TONS Power Supply : 380/3/60Hz General Specifications And other features : Semi-hermetic Screw compressors. Rubber pad Isolators. Copper tubes with Aluminum fins condenser. Insulated cooler with removable head. Designed to meet harsh ambient conditions and suitable for outdoor installtions. Microprocessor controlled performance. Phase protection for the unit. Thermal and overload protection for Compressors and Motors Pressure safety swithes and other standard refrigerantion circuit devices. CHILLED WATER PIPING & ACCESSORIES. Above ground and under ground Chilled water piping and fittings connecting the chiller to the inlet ports with black steel pipe including excavation of ground and covering up thereafterand including all necessary fitting (Elbow, Tee, Reducer ), valves , Automatic air vents, hanger, support as per drawings and specifications. ( Drawings to be submitted for approval prior to commencing the work at site.) 80 mm dia 100 mm dia 125 mm dia 200 mm dia PAGE TOTAL
M L/s 695,000 695,000
Unit NOS
Qty 1
1.0.0 1.1.0 1.2.0 1.3.0 1.4.0 1.5.0 1.5.1 1.5.2 1.5.3 1.5.4 1.5.5 1.5.6 1.5.7 1.5.8 1.5.9
2.0.0 2.1.0
M M M M
1,780,000
--
Option-08: 23 of 25
September 2012
PROCESS CHILLER OFFER (1Nos X 500 Tons @ 380/3/60Hz) Item # Description 50mm thick premoulded fibreglass pipe sectional insulation for chilled water pipe having 64 Kg/m density as per drawings and specifications 80 mm dia 100 mm dia 125 mm dia 200 mm dia Double regulating valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia Isolating Valve 80 mm dia 100 mm dia 125 mm dia 200 mm dia ELECTRICAL WORKS. Chiller Starter Chiller control panel Cabling works Includes all electrical and control cabling works between chiller and the available power supply point at site. TESTING AND COMMISSIONING. Testing and commissioning of the chiller plant system including cartage and unloading of the chillers.Operation and maintenance manual for the designed system complete with all equipment, components, accessories, fittings fixings, connections, cables, conduits, etc. as required and specified.
M M M M No. No. No. No. L/s L/s L/s L/s L/s L/s L/s L/s
Unit
Qty
Unit Price
2.2.0
2.2.3 2.2.4 2.2.5 2.2.6 2.3.0 2.3.1 2.3.2 2.3.3 2.3.4 2.4.0 2.4.1 2.4.2 2.4.3 2.4.4 3.0.0 3.1.0 3.2.0 3.3.0
4.0.0 4.1.0
Lot.
40,000
40,000
5.0.0
EXCLUSIONS. 5.1.0 Any Item not specified above. 5.2.0 Mounting structure (Steel or concrete) for the chiller.
PAGE TOTAL 195,000
--
Option-08: 24 of 25
September 2012
Description
Unit
Qty
Unit Price
Any re-routing of existing infrastructure encountered during excavation to lay pipes and cables. Any cabling work beyond 10 linear meters. The power supply to the chiller is expected to be located within a radius of 10 Meters.
5.4.0
GRAND TOTAL
1,975,000
--
Option-08: 25 of 25