World Class Switching Solutions for Energy Management 100A Power LAtChing reLAy
Contact Data
Rated load Contact form Contact material
Characteristics
Insulation resistance Dielectric strength: Coil to contact
100A 277Vac 1A or 1B AgSnO2 440Vac 120A 33,240VA 6,000 cycles 100,000 cycles
1,000M (at 500VDC) 4,000 Vac for 1 min. 2,000 Vac for 1 min. 8.0mm -40C to +70C 98%RH, +40C 1.5mm (DA), 10 to 55 Hz 10G 100G Approx. 75g Dust protected PCB
Max. switching voltage Max. switching current Max. AC switching power: Electrical endurance Mechanical endurance
Across open contacts Dielectric creepage Ambient temperature Ambient humidity Vibration Shock resistance: Functional* Destructive Unit weight Construction Termination
Coil Data
Single Coil (Latching) Coil Consumption Pulse Duration nominal Coil Voltage 6Vdc 9Vdc 12Vdc 24Vdc 48Vac 3W Min. 80ms Minimum operating Voltage 4.8Vdc 7.2Vdc 9.6Vdc 19.2Vdc 38.4Vac
Dual Coil (Latching) 6W Min. 80ms Coil resistance ( 10%) @ 23C Single Coil (Latching) 13 39 50 210 860 Dual Coil (Latching) 2 x 6.5 2 x 19.5 2 x 25 2 x 105 2 x 430
Fax: +1.888.511.3989 /
Email: info@kgtechnologies.net
/ Web: www.kgtechnologies.net
072012
K125
Ordering Information
K125 Relay Series: Terminal Type: Coil Type: Coil Voltage3: Coil Polarity: Contact Form: Contact Material:
1 2
Pg 2 of 3
012
1A
A: See drawings1 X: Custom design2 S: Single coil D: Dual coil 6, 9, 12, 24, 48 Vdc P: Positive N: Negative 1A: Form 1A NO 1B: Form 1B NC T: AgSnO2
Other standard terminal type drawings available upon request. For custom designs, please contact KG Technologies. Integrated shunts, flex-wire, copper extensions and brass terminals available. Coil voltage should be indicated in three digit format (6Vdc = 006)
Dimensional Drawings
All dimensions in mm unless otherwise noted. For more information, please contact KG Technologies.
43.0
22.0
37.0
Fax: +1.888.511.3989 /
Email: info@kgtechnologies.net
/ Web: www.kgtechnologies.net
072012
Dual Coil
Wiring Diagrams
Dual Coil
K125
T1 T2 T3
Pg 3 of 3
Single Coil
Single Coil
T1 T3
T1
T3
T1
T3
T1
T3
T1
T3
Positive Polarity
Negative Polarity
Positive Polarity
Negative Polarity
Application Notes
Dual Coil Positive Polarity: Place a negative connection on T2. Then apply an 80ms positive pulse to T1 to open the contacts or to T3 to close the contacts. Dual Coil negative Polarity: Place a positive connection on T2. Then apply an 80ms negative pulse to T1 to open the contacts or to T1 to close the contacts. Single Coil Positive Polarity: Place a negative connection on T1. Then apply an 80ms positive pulse to T3 to close the contacts. Place a positive connection on T1. Then apply an 80ms negative pulse to T3 to open the contacts. Single Coil negative Polarity: Place a positive connection on T1. Then apply an 80ms negative pulse to T3 to close the contacts. Place a positive connection on T1. Then apply an 80ms positive pulse to T3 to open the contacts.
Disclaimer: This data sheet is for reference only. All specifications are subject to change without prior notice. KG Technologies, Inc. cannot predict every possible application for our relays. While we do our best to make our relays as versatile as possible, we highly recommend contacting our engineering team if you have any questions. KG Technologies, Inc. is not responsible for malfunctioning relays when operated outside the specified parameters given in this data sheet.
KG Technologies, Inc. / Phone: +1.888.513.1874 / Fax: +1.888.511.3989 / Email: info@kgtechnologies.net / Web: www.kgtechnologies.net
072012