You are on page 1of 2

BD50F

Direct Current Compressor


R134a
12 - 24V

Compressors

Data Sheet (Replaces CD.46.B4.02)


Code numbers
101Z1220

BD50F

Electronic unit 12-24V DC - w. metal shielding single: 101N0220, 30 pcs: 101N0221


Electronic unit 12-24V DC - with AEO

single: 101N0300, 30 pcs: 101N0301

101Z

Application

R134a

Blue stripe

N 1297

Barcode on
white background

Application
Application

LBP/MBP/(HBP)

Evaporating temperature range

MADE IN GERMANY

Grey background

e4

-30 to 0 (10)

Voltage range / max. voltage

12 - 24V DC / 31.5V DC

Max. machine compartment temperature


Comp. cooling at ambient temp.

0277 00

55

EC approval mark

S or F1*

43C

S
O
F1

* depending on application

Design
Displacement

cm3

2.50

Oil quantity

cm 3

150

300

870

Maximum refrigerant charge


Free gas vol. in compressor

cm

Weight: Compressor/Electronic unit

1220

8369-2

single: 101N0210, 30 pcs: 101N0211

8415

BD50F without electronic unit


Electronic unit 12-24V DC - standard

kg

= Static cooling normally sufficient


= Oil cooling
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
= Fan cooling 3.0 m/s necessary

F2

4.3/0.25

Motor
Motor type

204
170

Variable speed

Resistance, all 3 windings (25C)

2.0
E4 72/245 95/54 0277 00

A
B
B1

137
135
128

B2

73

Suction connector

location/I.D. mm

6.2 0.09

Process connector

location/I.D. mm

6.2 0.09

Discharge connector

location/I.D. mm

5.0 +0.12/+0.20

pcs.

127

24V cut-out [V]


22.8

24V cut - in [V]


24.2

B1 B A

201

Resistor (R2) 12V cut-out 12V cut-in 12V max. 24V cut-out 24V cut-in 24V max.

January 2003

Voltage
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0
17.0

[V]
21.3
21.5
21.8
22.0
22.3
22.5
22.8
23.0
23.3
23.6
23.8
24.1
24.3
24.6

[V]
22.7
22.9
23.2
23.4
23.7
23.9
24.2
24.5
24.7
25.0
25.2
25.5
25.7
26.0

Voltage
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5
31.5

CD.46.B5.02

8269

16

46

[V]
10.9
11.0
11.1
11.3
11.4
11.5
11.7
11.8
11.9
12.0
12.2
12.3
12.4
12.5
10.9

105

[V]
9.6
9.7
9.9
10.0
10.1
10.2
10.4
10.5
10.6
10.8
10.9
11.0
11.1
11.3
9.6

B2

Optional battery protection settings


[k]
0
1.6
2.4
3.6
4.7
6.2
8.2
11
14
18
24
33
47
82
220

20

12V cut-in [V]


11.7

150

Standard battery protection settings (no connection C - P)


12V cut-out [V]
10.4

4.2

28

130

Compressors on a pallet

16

59

mm

120

Height

78.5

Dimensions

70
100

Approvals (electronic unit)

123

Capacity (EN 12900/CECOMAF)


rpm \ C
2,000
2,500
3,000
3,500

-30
20.1
27.0
31.0
38.1

-25
31.0
39.0
45.4
53.2

watt

-23.3
34.9
43.4
50.6
59.1

-20
42.8
52.7
61.5
71.9

-15
56.3
68.9
80.7
95.0

-10
72.2
88.9
104
124*

-5
91.6
113
134*
159*

0
115
144*
171*

5
144*
181*

-23.3
43.1
53.6
62.5
72.9

-20
52.9
65.0
75.9
88.7

-15
69.5
85.1
100
117

-10
89.3
110
129
153*

-5
113
140
166*
196*

0
143
178*
212*

5
178*
224*

10
178*
Terminal plug

Capacity (ASHRAE)
rpm \ C
2,000
2,500
3,000
3,500

-30
24.7
33.3
38.2
47.0

watt

-25
38.3
48.1
56.0
65.7

10
221*

8236-2

Power consumption
rpm \ C
2,000
2,500
3,000
3,500

-30
25.1
34.1
39.9
50.2

watt

-25
31.8
40.5
49.2
59.3

-23.3
34.0
42.9
52.2
62.5

-20
38.2
47.8
57.8
69.0

-15
44.7
55.8
66.5
80.2

-10
51.3
64.7
76.4
93.4*

-5
58.3
74.3
88.4*
109*

0
65.8
84.8*
104*

5
74.2*
96.1*

10
83.5*

Current consumption (for 24V applications the following must be halved)


rpm \ C
2,000
2,500
3,000
3,500

-30
2.2
2.9
3.5
4.2

-25
2.6
3.4
4.2
4.9

-23.3
2.8
3.6
4.4
5.2

-20
3.1
4.0
4.9
5.8

-15
3.8
4.7
5.6
6.7

-10
4.4
5.4
6.5
7.8*

-5
5.1
6.2
7.4*
9.0*

0
5.8
7.0*
8.5*

5
6.4*
7.8*

-30
0.80
0.79
0.78
0.76
-30
0.99
0.98
0.96
0.94

LED -

Fan

+
F
D
C
P
T

R1
Thermostat

R2

W/W

-25
0.98
0.96
0.92
0.90

-23.3
1.03
1.01
0.97
0.95

-20
1.12
1.10
1.06
1.04

-15
1.26
1.24
1.21
1.19

-10
1.41
1.37
1.37
1.32*

-5
1.57
1.53
1.51*
1.45*

0
1.75
1.70*
1.65*

5
1.94*
1.88*

-25
1.21
1.19
1.14
1.11

-23.3
1.27
1.25
1.20
1.17

-20
1.38
1.36
1.31
1.28

-15
1.56
1.53
1.50
1.46

-10
1.74
1.70
1.69
1.64*

-5
1.94
1.89
1.87*
1.80*

0
2.16
2.10*
2.04*

5
2.40*
2.33*

COP (ASHRAE)
rpm \ C
2,000
2,500
3,000
3,500

Power supply

10
6.9*

COP (EN 12900/CECOMAF)


rpm \ C
2,000
2,500
3,000
3,500

Main switch

Fuse

10
2.13*

W/W
10
2.65*

Test conditions
EN 12900/CECOMAF
ASHRAE
Condensing temperature
55C
55C
Ambient and suction gas temp.
32C
32C
Liquid temperature
55C
32C
Static cooling, 12V DC
* Fan cooling of electronic unit compulsory
Wire dimensions
1 Watt = 0.86 kcal/h

Compressor speed
Electronic Resistor
unit
(R1)

0
0
1
277
02 220
1N 0
692
10 01N
1523
1
0
173
00
3
0 EO
450
1N h A
0
865
i
1 wt
1696

Motor
speed
rpm
2,000
2,500
3,000
3,500
AEO
2,000
2,500
3,000
3,500

Contr.circ.
current
mA
5
4
3
2
6
5
4
3
2

In AEO (Adaptive Energy Optimizing) speed


mode the BD compressor will always adapt
its speed to the actual cooling demand.

Cross
section
mm2

Operational errors shown by LED (optional)

Max length* Max length*


m
m
12V operation 24V operation

2.5
4
6
10

2.5
4
6
10

5
8
12
20

Number
of
flashes

Error type

Thermal cut-out of electronic unit

Minimum motor speed error

Motor start error

Fan over-current cut-out

*Length between battery and electronic unit

Accessories
Devices

BD50F

Standard automobile fuse


Not
DIN 7258
12V: 15A
deliverable
24V: 7.5A
from Danfoss
Mounting accessories
Bolt joint for one compressor 118-1917
Bolt joint in quantities
118-1918
Snap on in quantities
118-1919

(If the refrigeration system has been too heavily loaded, or if the ambient temperature is
high, the electronic unit will run too hot).
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum
speed at approximately 1,850 rpm).
(The rotor is blocked or the differential pressure in the refrigeration system is too high
(>5 bar)).
(The fan loads the electronic unit with more
than 1A peak).

Battery protection cut-out


(The voltage is outside the cut-out setting).

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

CD.46.B5.02

January 2003

You might also like