You are on page 1of 4

Chemical & Process Technology: Determine Latent Heat for Multi-Component and Relieving Area Using Rig...

Page 1 of 4

Chemical & Process Technology


A place to share knowledge, lesson learnt...

Search
Web Chem & Proc Tech

CHEM & PROC TECH OIL & GAS TECH HEAT & EXCH TECH GEN TECH

HOME

ARCHIVE

LINK

FREE MAGAZINES

Ads by Google

Heat Transfer

Certificate

Specific Heat

Heat Pipe

Hot Posts
Useful Documents Related to Pressure Relief Valve (PRV) - Part 1 Pressure Relief Valve (PRV) has been widely use in overpressure protection of pressure containment equipment. Regardless of vessel/column/drum/tank designed in accordance to any pressure vessel code e.g. ASME, JIS, BS, GB, etc,...

Sunday, June 22, 2008

Determine Latent Heat for Multi-Component and Relieving Area Using Rigorous Method in HYSYS

FOLLOW ME

FREE Info
Free Newsletter Free Magazine

Latest Posts
New Material for DirectMethanol Fuel Cells (DMFC)... Trim Centrifugal Pump Impeller for Reduced Head What are the concerns related to H2S ? Quick Check if Pump Performance Curve (Water) is G... Quick Check if NPSHa is Sufficient Using Thoma Cav... Understand Droop Effect in Self-regulated Control Something You Can't Foresee if You Don't Know... Square-root-Square-root Formula Ease Saturated Ste... Useful Documentation for HYSYS ... Is Your Company "Green" Enough ?

Enter your email address: Display problem ? Click HERE

Subscribe

SUPPORT This Site

Links
Chem & Proc tech Oil & Gas tech A vessel with liquid at it boiling point exposing to external heat input from Fire would lead to liquid vaporization. Vaporization would subsequently leads internal pressure increases upto Pressure Relieve Valve (PRV) set pressure. The PRV will starts to open to relieve part of the vapor in order to maintain the vessel internal pressure within maximum allowable accumulated pressure (121% of PRV set pressure if the Vessel is designed to ASME Section VIII). Recommended : Subscribe FREE -Pipeline & Gas Technology Determination of Relieve load for boiling liquid would required latent heat of the boiling liquid in the vessel. Dealing with single component, the latent heat can be easily obtained from literature or HYSYS simulator. However, in real world system, the fluid could be a multi-component fluid which the latent heat will change from initial boiling point (IBP) for final boiling point (FBP). In addition, light component with lower latent heat and lower molecular weight will release first as compare to heavy component with higher latent heat and higher molecular weight. Latent heat change lead to different relieve load and different properties would result different relieving area. Those a rigorous method may required to determine maximum relieving area. Following are the steps can be used to determine the latent heat and maximum relieving area. HYSYS snapshot below may be referred when running through the steps. Heat Exch tech Gen Tech Webworm DC Chemical and Process Engineering Chemical Engineering World Smart Process Design ChEng

Visitors
(Since Apr. 21,2007)

http://webwormcpt.blogspot.com/2008/06/determine-latent-heat-and-maximum.html

21/11/2011

Chemical & Process Technology: Determine Latent Heat for Multi-Component and Relieving Area Using Rig... Page 2 of 4

(Click to view larger chart) STEP 1 : Define fluid in the vessel is at maximum Operating pressure (P0) & operating temperature (T0) prior to fire start. HYSYS : Stream 1 is at P0 & T0. Flash stream 1 in VESSEL V-100 and associate vapor and liquid outlet are stream 2 & 3. STEP 2a : Determine liquid volume (Vl0) and vapor volume (Vv0) which will be defined by the physical vessel dimension and piping volume. Calculate liquid volume (Vl0) and vapor volume (Vv0) consider liquid level in the vessel is at maximum liquid level (L0) and piping vapor & liquid volume. STEP 2b : Adjust the inventory (vapor mass and liquid mass) in the vessel until you achieve the vapor volume (Vv0) and liquid volume (Vl0). HYSYS : Copy stream 2 to stream 4. Copy stream 3 to stream 5. Mix stream 4 & 5 into stream 6. ADJUST stream 4 Mass Flow to obtain Stream 6 Vapor Actual Volumetric Flow to Vv0. ADJUST stream 5 Mass Flow to obtain Stream 6 Liquid Actual Volumetric Flow to Vl0. STEP 3 : Bring the the system to Relieving pressure (Pr0=121% of Pset). By maintaining system volume at V0 (=Vv0+Vl0). The system is at relieving condition. The temperature at this point is Tr0. HYSYS : Define a new stream 7 with a BALANCE unit (mole balance only). Set Stream 7 pressure at Pr0. ADJUST stream 7 temperature until Overall Actual Volumetric Flow to V0 (=Vv0+Vl0). STEP 4 : Next step is further input heat (Q1) to achieve 1-2 deg C above Tr0 but maintain pressure at Pr0. Normally the total volume (V1) at this point potentially higher than V0. HYSYS : Flash stream 7 in VESSEL V-101 into Vapor outlet, stream 6 and Liquid Outlet stream 11. Attach a heat stream (Q-100) into V-101. SET stream 8 temperature 1-2 degC above stream 7. STEP 5 : Part of the vapor (m1) from the system shall be removed in order to bring the system volume (V1) back to V0 as the physical volume maintain. HYSYS : SPLIT stream 8 into stream 9 and 10. Mix stream 9 & stream 11 form stream 12. ADJUST stream 9 Mass Flow (m1) to obtain Stream 12 Overall Actual Volumetric Flow to V0. STEP 6 : Above has shown that m1 (stream 9) will be removed with the heat input of Q1 (Q-100) and maintaining at set pressure. Heat input is used to heat the vapor and liquid from Tro to Tr1 (sensible heat) and vaporized m1 of liquid (Latent Heat of Vaporization). Latent Heat of Vaporization, Hvap = [Q1 - m8 x dT x (Cp7+Cp8)/2 - m11 x dT x (Cp7+Cp8)/2]/m9 where m8 - Mass of stream 8 (Vapor) m9 - Mass of stream 9 (Removed Vapor) m11 - Mass of stream 11 (Liquid) Cp7 - Stream 7 (Mixed) specific heat capacity Cp8 - Stream 8 (Vapor) specific heat capacity Cp11 - Stream 11 (Liquid) specific heat capacity dT = Tr0 - Tr1 STEP 7 : Determine Fire heat load input (Qc1) from API equation (Q=43.2A^0.82). STEP 8 : Determine PSV mass flow rate with M1= m1 x (Qc1/ Q1) STEP 9 : Calculate the Relief area (A1) base on M1 and fluid properties from stream 9. STEP 10 : Repeat (4) - (9) until you get the maximum Relief area (Amax). Recommended : Subscribe FREE -Security & Safety System One shall remember there are several assumptions have been considered in this method. One of them is Liquid properly disengaged from vapor and zero entrainment is assumed. Read more in "How Fluid Characteristic affect 2 phase Relief via PSV on Liquid filled Vessel Exposing to External Fire". Above method also assumed 100% heat input from fire will be transferred to fluid. No accumulation of heat in vessel metal is considered (for conservatism). The heat transfer rate at liquid is considered perfect to allow 100% heat transfer. The heat input into vessel exposing to vapor section, majority of the heat will stay in the metal. This is significantly reduce the vessel maximum allowable stress. Nevertheless, it was assumed the stress due to internal pressure is always lower than vessel maximum allowable stress throughout the relieving period.
Enter search terms... www.indeed.com Go

Ads by Google

Steam Heat Heat Sizing Heat Flow


Recommended Jobs Process Plant Manager Venezuela - CA Global Engineering Senior Chemical / Process Engineers Caracas - Suncor Energy Application Engineer (All Venezuela) Job Valencia - Nalco Field Service Representative FSR Job Caracas - GE Company European payroll manager Caracas

Related Topic

http://webwormcpt.blogspot.com/2008/06/determine-latent-heat-and-maximum.html

21/11/2011

Chemical & Process Technology: Determine Latent Heat for Multi-Component and Relieving Area Using Rig... Page 3 of 4

Useful Documentation for HYSYS ... Extend of Pool Fire... How Fluid Characteristic affect 2 phase Relief via PSV on Liquid filled Vessel Exposing to External Fire Extra Caution When Eliminating Overpressure by Fire Attacks Should we consider JET FIRE for Pressure Relief Valve (PSV) load determination ? PSV for Shell-and-Tube HEX Tube Side Overpressure Protection against External Fire Attack ? Should maximum recommended wall temperature (Tw) for carbon steel vessel used as design temperature ?

Labels: Fire, HYSYS, Overpressure Protection, Pressure Relief Device

empleos de Process engineer

Entry Level Field Engineer


Halliburton - Maturn
of-well reports. Provides on-site supervision of the Directional Drilling process including projection of well path to pre-determined target coordinates. Serves... Halliburton more jobs

Jobs by Indeed
posted by Webworm, 5:20 PM

No se puede encontrar la pgi


Causas ms probables: Es posible que la direccin no Si hizo clic en un vnculo, es p
-->

1 Comments:
Anonymous said... Quote: "...light component with lower latent heat..." It is a common misconception that light components latent heats (on mass basis) are lower than those of heavy components. In general, for hydrocarbon streams, light components have lower boiling points but higher massbased latent heats. So even though the light components in a mixture of hydrocarbons vaporize first, they require more heat to vaporize per unit of mass. May 22, 2009 1:02 PM

Post a Comment
Let us know your opinion !!! You can use some HTML tags, such as <b>, <i>, <a>

http://webwormcpt.blogspot.com/2008/06/determine-latent-heat-and-maximum.html

21/11/2011

Chemical & Process Technology: Determine Latent Heat for Multi-Component and Relieving Area Using Rig... Page 4 of 4

Comment as: Select profile...

Post Comment

Preview

Subscribe to Post Comments [Atom]

Links to this post:


Create a Link

Home:
<< Home

http://webwormcpt.blogspot.com/2008/06/determine-latent-heat-and-maximum.html

21/11/2011

You might also like