ROSA Detailed Report

Pgina 1 de 3

Reverse Osmosis System Analysis for FILMTEC Membranes Project: PERLAMAR giancarlo menegazzo, UAT de Venezuela
Project I nformation: Case-specific: System Details Feed Flow to Stage 1 Raw Water Flow to System Feed Pressure Flow Factor 139.00 gpm 139.00 gpm 841.03 psig 0.85 Pass 1 Permeate Flow Pass 1 Recovery Feed Temperature Feed TDS Number of Elements Average Pass 1 Flux 55.60 gpm 40.00 % 25.0 C 36042.06 mg/l 18 11.12 gfd

ROSA 7.2.7 ConfigDB u392554_148 Case: 1 8/30/2012

Osmotic Pressure: Feed 373.26 psig Concentrate 636.14 psig Average 504.70 psig Average NDP Power Specific Energy Avg Flux (gfd) 11.12 Perm Press (psig) 0.00 321.29 psig 63.58 kW 19.06 kWh/kgal Boost Press (psig) 0.00 Perm TDS (mg/l) 132.53

Chem. Dose (100% H2SO4) 0.00 mg/l Total Active Area 7200.00 ft Water Classification: Seawater (Well/MF) SDI < 3 Feed Flow (gpm) 139.00 Feed Press (psig) 836.03

Stage 1

Element SW30HRLE-400i

#PV #Ele 3 6

Recirc Flow (gpm) 0.00

Conc Flow (gpm) 83.40

Conc Press (psig) 812.82

Perm Flow (gpm) 55.60

Pass Streams (mg/l as Ion) Name NH4 K Na Mg Ca Sr Ba CO3 HCO3 NO3 Cl F SO4 SiO2 Boron CO2 TDS pH Feed 10.00 519.95 11491.90 1055.90 319.97 0.00 0.00 2.76 135.51 22.00 19726.88 1.00 2755.26 1.00 0.00 4.29 36042.15 7.20 Adjusted Feed 9.91 519.95 11491.90 1055.90 319.97 0.00 0.00 2.76 135.51 22.00 19726.89 1.00 2755.26 1.00 0.00 4.29 36042.06 7.20 Concentrate Stage 1 16.53 864.73 19121.47 1759.25 533.11 0.00 0.00 7.01 220.50 36.04 32826.56 1.66 4591.45 1.66 0.00 5.75 59979.89 7.30 Permeate Stage 1 Total 0.20 0.20 2.79 2.79 47.78 47.78 0.89 0.89 0.27 0.27 0.00 0.00 0.00 0.00 0.00 0.00 0.91 0.91 0.95 0.95 77.78 77.78 0.01 0.01 1.04 1.04 0.01 0.01 0.00 0.00 4.61 4.61 132.53 132.53 5.46 5.46

Permeate Flux reported by ROSA is calculated based on ACTIVE membrane area. DISCLAIMER: NO WARRANTY, EXPRESSED OR IMPLIED, AND NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS GIVEN. Neither FilmTec Corporation nor The Dow Chemical Company assume any obligation or liability for results obtained or damages incurred from the application of this information. Because use conditions and applicable laws may differ from one location to another and may change with time, customer is responsible for determining whether products are appropriate for customer s use. FilmTec Corporation and The Dow Chemical Company assume no liability, if, as a result of customer's use of the ROSA membrane design software, the customer should be sued for alleged infringement of any patent not owned or controlled by the FilmTec Corporation nor The Dow Chemical Company.

file:///C:/Program%20Files%20(x86)/ROSA72/MyProjects/PERLAMAR01Detail.html

30/08/2012

ROSA Detailed Report

Pgina 2 de 3

Reverse Osmosis System Analysis for FILMTEC Membranes Project: PERLAMAR giancarlo menegazzo, UAT de Venezuela
Design Warnings -NoneSolubility Warnings

ROSA 7.2.7 ConfigDB u392554_148 Case: 1 8/30/2012

Langelier Saturation Index > 0 CaF2 (% Saturation) > 100% Antiscalants may be required. Consult your antiscalant manufacturer for dosing and maximum allowable system recovery. Stage Details Stage 1 Element Recovery 1 2 3 4 5 6 0.10 0.09 0.09 0.08 0.07 0.06 Perm Flow (gpm) 4.55 3.94 3.33 2.75 2.22 1.75 Perm TDS (mg/l) 74.30 93.55 119.62 155.12 203.67 270.20 Feed Flow (gpm) 46.33 41.78 37.85 34.52 31.77 29.55 Feed TDS (mg/l) 36042.06 39958.14 44103.65 48342.68 52509.49 56435.31 Feed Press (psig) 836.03 830.83 826.30 822.34 818.84 815.69

Permeate Flux reported by ROSA is calculated based on ACTIVE membrane area. DISCLAIMER: NO WARRANTY, EXPRESSED OR IMPLIED, AND NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS GIVEN. Neither FilmTec Corporation nor The Dow Chemical Company assume any obligation or liability for results obtained or damages incurred from the application of this information. Because use conditions and applicable laws may differ from one location to another and may change with time, customer is responsible for determining whether products are appropriate for customer s use. FilmTec Corporation and The Dow Chemical Company assume no liability, if, as a result of customer's use of the ROSA membrane design software, the customer should be sued for alleged infringement of any patent not owned or controlled by the FilmTec Corporation nor The Dow Chemical Company.

file:///C:/Program%20Files%20(x86)/ROSA72/MyProjects/PERLAMAR01Detail.html

30/08/2012

ROSA Detailed Report

Pgina 3 de 3

Scaling Calculations Raw Water 7.20 0.14 -0.85 0.72 36042.15 135.51 4.29 2.76 15.68 0.00 0.00 42.54 0.80 0.01 Adjusted Feed 7.20 0.14 -0.85 0.72 36042.06 135.51 4.29 2.76 15.68 0.00 0.00 42.54 0.80 0.01 Concentrate 7.30 0.66 -0.55 1.23 59979.89 220.50 5.75 7.01 29.11 0.00 0.00 196.04 1.33 0.02