Technical data Entire device

2.5 APC620 embedded variant


2.5.1 Interfaces

Add-on UPS slot Ethernet POWERLINK Ethernet 10/100 MBit COM1 CAN Status LEDs CAN / X2X
Supply voltage +24 VDC

Monitor/Panel SDL (Smart Display Link) / DVI 4 x USB LED for: Power CF Link X2X Heat sink Heat sink seal warning COM2

Figure 17: APC620 embedded variant interface overview - top side

Warning!
Do not remove the mounting screws from the heat sink, as it is connected to the processor and chipset by a thermal coupling. Should this connection be broken, the APC620 embedded must be sent for repair. Removal of the mounting screws, which can be determined by a broken seal, voids all warranty. During operation, surface temperatures of the heat sink may reach 70C (warning "hot surface").

72

Automation PC 620 User's Manual V 2.41

060003861

VOID WARRANTY IF SEAL BROKEN

Technical data Entire device

Status LEDs for: Power, CF, Link

CompactFlash slot 2 - CF2 CompactFlash slot 1 - CF1 CAN terminating switch Permanent magnet CAN terminating LED Serial number sticker Power button Hardware security key Power button CAN node number (x16, x1) Battery Ethernet POWERLINK station number (x16, x1)

Figure 18: APC620 embedded variant interface overview - front side

Information:
The orange front doors contain two permanent magnets. Contact between a data carrier that saves data magnetically (hard disk, diskette, the magnetic strip of a credit card, etc.) and a magnet can cause loss of data.

Automation PC 620 User's Manual V 2.41

73

Chapter 2 Technical data

Technical data Entire device 2.5.2 Technical data


Features Boot loader / Operating system Processor Cooling Method Main memory Graphics Controller Power failure logic Controller Buffer time Real-time clock Battery-buffered Accuracy Battery Type Removable Lifespan Ethernet Controller Amount Ethernet POWERLINK Amount Station number switches X2X Link Amount Status LED CAN bus Amount Transfer rate Node switch Terminating resistor Status LED CompactFlash Type Amount Serial interface Amount Type UART Transfer rate Connection USB interface Type Amount Transfer rate Connection Current load Reset button APC620 embedded variant BIOS / see the chapter 4 "Software" on page 337 Component-dependent, see technical data for the CPU board Passive via heat sink Max. 1 GB with 855GME CPU board Component-dependent, see technical data for the CPU board on page 169 MTCX1) (see also page 739) 10 ms, dependent on the system unit revision (see page 525) Yes Component-dependent, see technical data for the 855GME (XTX) CPU board See also page 145 Renata 950 mAh Yes, accessible behind the orange cover 2 1/2 years2) Yes See also page 117 1 Yes, also see page 115 1 2 pcs. Yes, also see page 113 1 Yes, see page 115 See also page 113 1 Max. 500 kBit/s Yes Yes, can be activated using a switch Yes, see page 115 See also page 142 Type I 2 See also page 111 or page 112 2 RS232, modem-capable, not electrically isolated 16550-compatible, 16-byte FIFO Max. 115 kBaud 9-pin DSUB See also page 122 USB 2.0 4 Low speed (1.5 MBit/s), full speed (12 MBit/s), to high speed (480 Mbit/s) Type A Max. 500 mA or 1 A per connection Yes, accessible behind the orange cover

Table 26: Technical data - APC620 embedded variant

74

Automation PC 620 User's Manual V 2.41

Technical data Entire device


Features LEDs Add-on UPS slot Electrical characteristics Power supply Rated voltage Rated current Starting current Power consumption Mechanical characteristics Housing3) Material Paint Front cover Outer dimensions Weight Environmental characteristics Ambient temperature Operation Storage Transport Relative humidity Operation Storage Transport Vibration4) Operation (continuous) Operation (occasional) Storage Transport Shock5) Operation Storage Transport Protection type Altitude Operation Electromagnetic compatibility Emissions Network-related emissions Emissions EN 61000-6-4, EN 55022 A EN 61000-6-4, EN 55011 class A, EN 55022 class A, EN 61131-2, 47 CFR Part 15 Component-dependent, see the section about ambient temperature on page 82 -20C .. +60C -20C .. +60C Component-dependent, see section "Humidity specifications" on page 108 Component-dependent, see section "Humidity specifications" on page 108 Component-dependent, see section "Humidity specifications" on page 108 2 - 9 Hz: 1.75 mm amplitude / 9 - 200 Hz: 0.5 g 2 - 9 Hz: 3.5 mm amplitude / 9 - 200 Hz: 1 g 2 - 8 Hz: 7.5 mm amplitude / 8 - 200 Hz: 2 g / 200 - 500 Hz: 4 g 2 - 8 Hz: 7.5 mm amplitude / 8 - 200 Hz: 2 g / 200 - 500 Hz: 4 g 15 g, 11 ms 30 g, 15 ms 30 g, 15 ms IP20 max. 3000 m5) (component-dependent) Galvanized plate, plastic Light gray (similar to Pantone 427CV), dark gray (similar to Pantone 432CV) Colored orange plastic (similar to Pantone 144CV) See section "Dimensions" on page 77. approx. 1.4 kg (component-dependent) 24 VDC 25% 3.8 A Typ. 7 A, max. 40 A for < 300 s Component-dependent, see section 2.12 "Power management for the APC620 embedded system unit" APC620 embedded variant 3 directed outwards via fiber optic lines, see also section "Status LEDs Power, CF, Link (only APC620 embedded)" on page 139 Yes

Table 26: Technical data - APC620 embedded variant (cont.)

Automation PC 620 User's Manual V 2.41

75

Chapter 2 Technical data

Technical data Entire device


Electromagnetic compatibility Immunity Electrostatic discharge (ESD) High-frequency electromagnetic fields High-speed transient disturbances (Burst) Surges Conducted values Magnetic fields with electrical frequencies Voltage dips, interruptions Damped vibration APC620 embedded variant EN 61000-6-2, EN 61131-2, EN 55024 EN 61000-6-2, EN 61131-2, EN 55024 EN 61000-6-2, EN 61131-2, EN 55024 EN 61000-6-2, EN 61131-2, EN 55024 EN 61000-6-2, EN 61131-2, EN 55024 EN 61000-6-2, EN 61131-2, EN 55024 EN 61000-6-2, EN 61131-2, EN 55024 EN 61000-6-2, EN 61131-2, EN 55024

Table 26: Technical data - APC620 embedded variant (cont.)


1) Maintenance Controller Extended. 2) at 50C, 8.5 A of the supplied components and a self discharge of 40%. 3) Depending on the process or batch, there may be visible deviations in the color and surface structure. 4) Maximum values, as long as no other individual component specifies any other. 5) Derating the maximum ambient temperature - typically 1C per 1000 meters (from 500 meters above sea level).

76

Automation PC 620 User's Manual V 2.41

Technical data Entire device 2.5.3 Dimensions

58 11.5 35 5.4 24 9 2.5 10.7

11

42.5

210

18

19

68.3 3 52.5 12.8

15

225.6

220

217

Nominal General tolerance according measurement area to DIN ISO 2768 medium up to 6 mm 0.1 mm over 6 to 30 mm 0.2 mm over 30 to 120 mm 0.3 mm over 120 to 400 mm 0.5 mm over 400 to 1000 mm 0.8 mm

58

Figure 19: APC620 embedded variant - dimensions

Automation PC 620 User's Manual V 2.41

77

Chapter 2 Technical data

125.1

183.8

200

Technical data Individual components 3.1.2 APC620 embedded variations


Features Photo
5PC600.SE00-00 5PC600.SE00-01 5PC600.SE00-02

Serial interfaces Type Amount UART Transfer rate Connection Ethernet Controller Transfer rate Connection Ethernet POWERLINK Amount Station number switches X2X Link Amount Status LED CAN bus Amount Transfer rate Node switch Terminating resistor Status LED USB interface Type Amount Transfer rate Connection Monitor / Panel AC97 sound IF optional slot PCI slots half-size full-size PCI standard Bus speed CompactFlash slot 1 (CF1) Internal organization CompactFlash slot 2 (CF2) Internal organization

RS232, modem capable 2 16550-compatible, 16-byte FIFO Max. 115 kBaud 9-pin DSUB, male See "Ethernet connection ETH (only APC620 embedded)" on page 117 10/100 Mbit/s RJ45 twisted pair (10 BaseT / 100 BaseT) 1 2 pcs. 1 Yes, see page 115 See also page 113 1 Max. 500 kBit/s Yes Yes, can be activated using a switch Yes, see page 115 USB 2.0 4 Up to 480 Mbit (high speed) Type A DVI-I, female -

integrated Primary master integrated Primary slave

Table 74: Technical data - APC620 embedded variations

Automation PC 620 User's Manual V 2.41

163

Chapter 2 Technical data

Technical data Individual components


Features Insert for slide-in drive 1 Internal organization Insert for slide-in drive 2 Internal organization APC620 UPS module optional SRAM Quantity Reset button Power button PS/2 keyboard/mouse Battery slot Hardware security key slot Fan slot Automation Panel link slot Status LEDs Real-time clock (RTC) Battery-buffered Accuracy MTCX1) Electrical characteristics Power supply Rated voltage Starting current Power consumption Mechanical characteristics Housing2) Material Paint Front cover Outer dimensions Width Length Height Weight Mounting plates (for M4 screws) Drilling templates for mounting Galvanized steel plate Light gray (similar to Pantone 427CV), dark gray (similar to Pantone 432CV) Colored plastic (similar to Pantone 144CV) 68.3 mm 225.6 mm 210 mm Approx. 1.3 kg 4 (see chapter 3 "Commissioning", section 1.2 "Drilling templates") 24 VDC 25% Typically 7A maximum 40 A for < 300 s See section 2.12 "Power management for the APC620 embedded system unit". Yes 512 kB
5PC600.SE00-00 5PC600.SE00-01 5PC600.SE00-02

Yes Yes 512 kB Yes Yes Yes Yes (DS1425 from MAXIM/Dallas) Power, HDD, Link1 Yes See the technical data for the CPU board Yes Yes 1 MB

Table 74: Technical data - APC620 embedded variations (cont.)


1) Maintenance Controller Extended, for more information, see the section "Maintenance Controller Extended (MTCX)" on page 739. 2) Depending on the process or batch, there may be visible deviations in the color and surface structure.

164

Automation PC 620 User's Manual V 2.41