Professional Documents
Culture Documents
2012-2013
Product Catalogue
APPLIED SYSTEMS
Beijing - China
Lyon - France
Barcelona - Spain
Baligen - Germany
One of the largest Italian groups in the heating and air conditioning industry. Our mission
Improve quality of life in public, residential and tertiary sector with a highly specialised oer of products and services for air conditioning, with maximum attention to customer needs and from the point of view of sustainable development suited to green building technologies. Know-how and experience at the service of specialists.
Since 1963, IRSAP has been a leader in the production of steel tubular radiators. IRSAP is the pulsating heart of the group: it combines the heat of fire with a burning passion for well-being.
OFFICINA DELLE IDEE line dedicated to design radiators. OFFICINA DELLE IDEE introduces an unmistakable style to every environment, giving a form to every desire.
Since 1968, RHOSS has worked in the public and industrial air conditioning sector. RHOSS is a breath of fresh air for your body and mind, thanks to products and systems that innovate air conditioning.
IR TECH is a company specialised in radiant cooling and heating system and renewable sources. IR TECH designs solid bases for climate management and is able to irradiate innovation and professionalism.
New EV series fan coil units (Brio EV and Yardy EV), with high performance and an exclusive design.
EXP has been created, an innovative polyvalent heat pump for 2 and 4-pipe applications.
Introduction of the R134a and R410A range for maximising energy performance.
2000
2002
Reengineering of the product range and expansion of the production lines with the implementation of a testing cabin on each line.
Eurovent certification for chilllers, heat pumps and fan coil units.
2005
Who is RHOSS
Rhoss is a company of Irsap group specialised in the design and production of air conditioning and air handling products and systems. For more than 40 years, Rhoss has been a guarantee for innovation, quality and top level service. This is what makes us an ideal partner for HVAC system specialists. RHOSS's growth and development is an evolution that combines investments and projects in order to make the company a point of reference also in international markets. Our renewal has followed market developments and customer needs, in particular offering highly efficient products and systems that are in line with the requirements of the most modern Green Buildings.
Y-M.I.C.H. has been created, inverter technology used for chillers and heat pumps.
Two other innovations include Dry-Pool, the first dehumidifier for pools in R410A, with heat recovery and Yardy HP, a high performance ducted fan coil unit.
Heating, cooling and hot water production solutions based on high performance, NF certified heat pumps. Low consumption" technology for managing R410A chillers and heat pumps, to reduce seasonal energy consumption.
Class A Y-POWER range with R410a gas. MODULART range of air handling units with regulation with high service levels.
2008
TEcHNOLOGicaL iNNOVaTiON
Development of innovative solutions to maximise comfort and energy saving performance. We have a permanent research contract with Universities to support innovation.
From machine certification to system certification in reference to the main air quality and environmental comfort measurement standards. IR TECH, a radiant air conditioning division of Rhoss, oers an advanced integrated system that maximises comfort, reducing the system's energy requirements. The innovative system was developed in Rhoss's new R&D Lab, which is able to simulate a buildingunit system.
2012
Therefore, Rhoss is able to offer products designed for large and small capacity systems, guaranteeing that all the components used are integrated together, with a perfect control logic. This result can only be obtained in laboratories such as Rhoss's R&D Lab, that is, in a complex, technically advanced structure that most other manufacturers today do not have.
aPPLiED SYSTEMS Chillers, fan coil units and terminal units for public, commercial and industrial applications, for small and large systems.
HEaT PUMPS Heat pumps and heating, cooling and hot water production solutions specifically for residential and small service industry applications.
aiR HaNDLiNG SYSTEMS Air handling units for public, commercial and industrial uses. Dehumidifiers for indoor pools.
RaDiaNT SYSTEMS Radiant air conditioning systems that integrate oor, wall and ceiling terminals with chillers/heat pumps, air handling units and complete system regulation. The oered solutions are specific for residential, commercial and large building applications.
the new ranges of dedicated AHUs: FLUXBLOCK, ROTOBLOCK, RIGENERA and ADIABATICA The Green-Line systems are: Systems based on high efficiency heat pumps specifically for residential and small service industry solutions. Thanks to the wide range of plant engineering solutions, these systems make it possible to meet the entire heating and hot water production requirement using renewable sources The solutions from the IR TECH division: integrated radiant air conditioning and air handling solutions
Summer saving
Electric energy consumed (kWh) Electric energy consumed (kWh)
Winter saving
April
May June July August September Compact-Y twin-compressor unit, 3 capacity steps with Adaptive Function Plus Tandem twin-compressor unit, 2 capacity steps with traditional control
October
September October November December January February Compact-Y twin-compressor unit, 3 capacity steps with Adaptive Function Plus Tandem twin-compressor unit, 2 capacity steps with traditional control
March
April
Dynamic analysis performed for an oce building in Milan, comparing the functioning of a reversible heat pump with two compressors with equal power operating on the same cooling circuit, which works with traditional control with xed Set-point (7C in the summer season and 45C in the winter season)
and a Compact-Y unit with three capacity steps that work with Adaptive Function Plus logic with shifting Set-point (range between 7 and 14 C in the summer season, range between 35 and 45C in the winter season).
The dynamic an cooling unit in alysis for the calculation of a energy consum used to compa building-unit system are ge ption of a ne re required, which dierent cooling machines rally too elaborated to be quickly as a ra is not always av nge of data is For a quick es ailable to the tim designer. with Adaptiv ate of what the energy savi ng e Fu traditional cont nction Plus software with could be using a machine rol, we theref ore propose a respect to a machine with the following formulas: simplified met hod that uses 0.54 x N x C E= ESEER + E = electric en ergy absorbed by the chiller fi Plus software tted with Adap [kW tive Function N = number of h] chiller functio ning hours C = chiller nom inal cooling ca pacity [kW ] ESEER + = av erag Function Plus e seasonal efficiency of th e chiller fitted software with Adaptiv e 0.54 x N x C E= ESEER E = electric en ergy absorbed by the chiller [kWh] fitted with tra ditional contro N = number of l chiller functio ning hours C = chiller nom inal cooling ca pacity [kW ]
Simplied m eth the calculatio od for n with Adaptiv of energy saving e Function Plu s
seasonal EER) Average Euro pean seasonal Therefore, with efficiency equal nominal number of wor cooling capacit king hours of y and suppos the two coolin ing the same the electric en g units ergy absorbed efficiency of will be greate with dierent controls, the unit itsel r the less th f. For simplici example on a e seasonal ty, w Rh Function Plus oss machine with traditiona e propose a calculation l control and w control: ith Adaptive EXAMPLE
TCAEY 260 mode l fitted with tradit software: ional
Nominal cooling N = 8 hours/day capacity = 59.2 kW x (5monthsx30d 1200 hours ays/month) = ESEER = 4.38 E= 0.54 x 1200 x 59 .2 = 8,758.4 kW/h 4,38
TCAEY 260 mode Adaptive Func l fitted with control with Nominal coolingtion Plus software: N = 8 hours/day capacity = 59.2 kW x (5monthsx30d 1200 hours ays/month) = ESEER = 5.04 E= 0.54 x 1200 x 59 .2 = 7,611.4 kW/h 5,04
The energy savi Function Plus ng that can be obtained , therefore w is 13%. ith Adaptive
www.eurovent-certification.com www.certiflash.com
www.eurovent-certification.com www.certiflash.com
Rhoss participates in the certification programme for air handling units with the ADV range that includes: Certification of performance according to the EN 13053 Standard Certification of the mechanical features according to EN1886 Energy classification of the machines
Eca cERTificaTiON fOR cHiLLERS The Rhoss chillers in the Y-Pack and Z-Power ranges and in the industrial range have also received ECA - Enhanced Capital Allowances - certification, which is a key programme from the English government that promotes criteria for energy savings and environmental wellness. ECA makes it possible for companies in the United Kingdom to benefit from tax incentives for investments in equipment, in the specific case of chiller assemblies, that satisfy certain energy efficiency values and are therefore able to contribute towards energy savings and a reduction in carbon emissions as set forth by the Kyoto protocol.
Nf Pac cERTificaTiON fOR HEaT PUMPS The Rhoss Mini-Y Revolution and Compact-Y heat pumps are NF PAC certified, which is a voluntary certification of quality that is issued by the French certification agency AFAQ-AFNOR. NF PAC applies to heat pumps with a heating capacity of up to 50 kW and certifies performance in terms of minimum COP, heating capacity and sound power level, in accordance with the requirements of the NF PAC Regulation. Before issuing the NF PAC certification, AFAQ-AFNOR carries out performance tests on the heat pumps representative of the certified ranges and performs company audits to evaluate manufacturer reliability.
RHOSS SMiLE SERVicE cONTRacTS - WaRRaNTY EXTENSiON Extended warranties are possible for all Rhoss units, which include labour and replacement parts for parts that are defective during the preselected extension period. Warranty coverage requires the execution of all ordinary maintenance operations through the scheduled maintenance contacts (Basic, Program, full Service and Global) in order to satisfy your needs, your company and your application. They are designed to oer operative eciency, extend the useful life of your system and help reduce operational costs. Selecting a Rhoss Smile Service contract is an antistress strategy. The advantages of purchasing a Rhoss Smile Service contract are unquestionable: in addition to having greater response priority, maintenance and component coverage, customers who sign a contract have the advantage of efficient planning and money savings. In fact, with a service contract administrative costs and internal and external labour costs are reduced substantially, and provide operational cost savings. The longer the contract, the more you save. Rhoss Smile Service contracts can be signed for a period of up to 10 years.
MacHiNE fOR TEMPORaRY USE - RENTiNG The right machine at the right moment and for the necessary amount of time: Rhoss Smile Service also means medium and long term renting of air conditioning and heating equipment. Rhoss Smile Service oers a wide range of versatile machines that can satisfy all cooling needs with an all inclusive formula. The supply foresees a turn-key rental, quick and timely coverage of any risk connected to maintenance and operating costs. The fixed rates represent certain costs that simplify accounting and a company's financial forecasts with rental fees being considered operational costs and therefore fully deductible. customers can add to or replace their equipment at any moment with a fee adjustment. The main eld of use are ice rinks (specic machines for working at low temperatures) and machines for the wine sector.
EXTRaORDiNaRY MaiNTENaNcE - UNiT RE-aSSEMBLY Increasingly often, architectural barriers and structural constraints make it impossible to replace units in areas that are difficult to reach due to weights and dimensions that do not conform with the available spaces. Rhoss Smile Service has a team of specialised technicians who are able to perform on site disassembly and reassembly operations for the machine to be positioned. If units not covered by Rhoss Smile Service contracts and no longer in the warranty period have defective vital machine components, the Rhoss Smile Service team is able to accept any request for service and will quickly organise: a technical inspection, preparation of a repair estimate, repair service following approval of the estimate, 12 months warranty on the work that was performed and reactivation of the global warranty for an additional 6 months starting from the date the work was completed.
Contents
16
APPLIED SYSTEMS
WATER CHILLERS - HEAT PUMPS
Air-cooled - Axial fans
Heating capacity: 4.515.9 kW Mini-Y Revolution Range Cooling capacity: 5.511.1 kW P. 22 Low consumption Mini-Y Range P. 24
THAIY 104115
Brushless DC rotary inverter hermetic compressors
TCAEY 105111
Hermetic Scroll compressors
Web code:
MYRE
Web code:
C0MY
THAEY 105111 NF
Hermetic Scroll compressors
P. 26
P. 28
THAEY 115127 NF
Hermetic Scroll compressors
Web code:
MYNF
Web code:
CYNF
Heating capacity: 8.719.1 kW Low consumption Compact HT Range Hermetic Scroll compressors
Heating capacity: 16.841.7 kW Low consumption Compact-Y Range Hermetic Scroll compressors
TCAEY-THAEY 115238
Web code:
P. 32
C0C1
C0CY
Heating capacity: 47.867.9 kW Low consumption Compact-Y Range Hermetic Scroll compressors
TCAEY-THAEY 245265
Web code:
TCAIY-THAIY 124-150
Hermetic Scroll compressors Inverter
Web code:
P. 36
C1CY
CYMI
Heating capacity: 79175 kW Low consumption Y-Pack Range Hermetic Scroll compressors
TCAEY-THAEY 2702160
Web code:
Heating capacity: 167353 kW Low consumption Y-Pack EVO Range Hermetic Scroll compressors
TCAEY-THAEY 41604320
Web code:
P. 40
C2Y1
C2Y2
TFAEY-TGAEY 41604320
Web code:
P. 42
P. 44 P. 46
FREE
C3Y1 C3Y2
Web code:
Z-Power Range P. 48 P. 52 P. 56
Web code:
P. 50 P. 54
P. 58
TCAIIZ 252021030
P. 60
C5Z1 C4Z2
C3ZI
COOLING ONLY
HEAT PUMP
OUTDOOR INSTALLATION
INDOOR INSTALLATION
17
THAVZ 24002680
C5Z2
TPW1 TPW2
TCCEY-THCEY 105111
Hermetic Scroll compressors
Web code:
TCCE-THCE 114126
Web code:
P. 68
MYCE
COCE
TCCE-TCPE-THCE-THPE 130270
Hermetic Scroll compressors
Web code:
TCCETY-THCETY 2332160
Hermetic Scroll compressors
P. 72
C2CT
Web code:
YPCE
TCHEY-THHEY 105112
Hermetic Scroll compressors
Web code:
C5CF
Web code:
YFL1
TCHEY-THHEY 2454450
Hermetic Scroll compressors
Web code:
YFL2 YFL3
C3FZ C3FE
TCHVZ 120031630
Semi-hermetic screw compressors
Web code:
TCEE 1054260
Hermetic Scroll compressors
C1FZ C2FZ
Web code:
C1FS
TCEVZ 120031630
Semi-hermetic screw compressors
Web code:
C1FE C2FE
TCAEY 1182189
Hermetic Scroll compressors
P. 90
Web code:
C2CQ C3CQ
TERMINAL UNITS
P. 86
SYSTEM ACCESSORIES
Z-Flow Range
P. 82
Mini-Q Flow E Range (mod. 105-115) Compact Flow E Range (mod. 120-165) Q-Flow E Range (mod. 280-4260)
P. 84
CONDENSING UNITS
TCHEY-THHEY 115240
P. 76
P. 62
T-Power Range
P. 64
18
TXAEY 117133
Hermetic Scroll compressors
TXAEY 245265
Hermetic Scroll compressors
P. 96
Web code:
C2Q6
Web code:
C2Q7
TXAEY 2804320
Web code:
TXAVZ 24202700
Semi-hermetic screw compressors
Web code:
P. 100
C2Q0
C2Q9
TXHEY 105112
Hermetic Scroll compressors
TXHVZ 24102740
Semi-hermetic screw compressors
Web code:
P. 104
Web code:
C2Q4
C2Q5
Condensing units
Cooling capacity: 7.626.3 kW Heating capacity: 929.9 kW Cooling capacity: 30.5-181.1 kW P. 106
MCAE-MHAE 108127
Hermetic Scroll compressors
MCAE 1312181
Hermetic Scroll compressors
P. 108
Web code:
C0MC
Web code:
C2MC
SYSTEM ACCESSORIES
Remote condensers Axial fans
CCAM 1052130
Web code:
P. 110
Cooling towers
P. 112
AUCR
CIV1
AS 03002500
Web code:
P. 114
PBHI 0200-0400
Web code:
Pumping groups
P. 116
CIV2
CIV3
RHOSS SEQUENCER
P. 118
RHOSS SUPERVISOR
P. 119
19
IDROWALL
BRIO-I
P. 126
BRIO-EV
YARDY-I
P. 130
Floor and ceiling, recessed or false ceiling fan coil units with brushless motor
YARDY-EV
YARDY-EV
P. 134
WVYE
Web code:
WVYE
YARDY-DUCT
P. 136
Ductable fan coil units for recessed horizontal or vertical installation Air flow rate: 275940m3/h
Web code:
YARDY-HP
P. 138
Ductable fan coil units for recessed horizontal or vertical installation Air flow rate: 1,5503,875 m3/h
Web code:
WVYD
WVY2
UTNC-EV
P. 140
VTNC
P. 142
UTTC
VTNC
Ductable terminal air handling units in sections Air flow rate: 8501,680 m3/h
Web code:
Ductable terminal air handling units in sections Air flow rate: 1,800-16,500 m3/h
Web code:
UTB1
UTA1
Fresh air terminal units with crossed ows static heat recovery
Web code:
UTNR
VMC-E
P. 154
UTNR
P. 122
Web code:
UTNR
Web code:
WAWR
TERMINAL UNITS
iDRHOSS
P. 120
UP TO DATE
P. 20
Fresh air terminal units with countercurrent ows static heat recovery
SYSTEM ACCESSORIES
P. 150
UTNR-HE
P. 152
CONDENSING UNITS
UTNB
UTNA
P. 146
Cooling capacity: 25 kW
WVB1
Web code:
WVYI
IN
IN
ER TE R
ER
WVID
Web code:
WVBI
IN
IN
ER TE R
ER
RHOSS Software
20
ASSISTED SELECTION
ENERGY RATING
DOCUMENTATION
THAIY 104115
Heating capacity: 4.515.9 kW
IN
IN
ER T ER
Operation with outdoor air down to 20C Hot water up to 60C Inverter compressor with continuous modulation of the capacity according to the requirement
Packaged air-cooled reversible heat pumps with axial fans. Range with hermetic rotary compressors DC brushless Inverter and refrigerant gas R410A.
Construction features
Compressor: hermetic rotary type twin-rotary DC brushless (single-rotary for the 4kW size), complete with thermal protection and crankcase heater, activated by inverter. Expansion valve: electronic. Water side heat exchanger: stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water ow switch. Air side heat exchanger: featuring nned coil with copper pipes and aluminium ns, complete with protection grille. Fan: axial fan rotor with DC brushless motors, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control. Accompanying the advanced remote keyboard with display. External temperature probe for set-point compensation. Structure: in galvanised and painted sheet steel, complete with condensation drain pan.
Models
PUMP unit
Pump assembly complete with: circulation pump, expansion tank, manual air bleed valve, safety valve.
3-way valve for the production of hot water, managed by regulation. Antivibration rubber mountings. Water lter. Outdoor air sensor with remote control option.
HEAT PUMP
OUTDOOR INSTALLATION
23
Heating capacity MIN/NOM/MAX Absorbed power NOM C.O.P. NOM (**) (***) Heating capacity Absorbed power C.O.P. Cooling capacity MIN/NOM/MAX E.E.R. NOM (***) Fan coil systems Heating capacity MIN/NOM/MAX Absorbed power NOM C.O.P. NOM Cooling capacity MIN/NOM/MAX E.E.R. NOM E.S.E.E.R. Sound power level / Sound pressure level Circulation pump available head pressure Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight
kW kW kW kW kW
1,08/5,80/6,14 1,38 4,20 3,50 1,46 2,40 1,20/7,00/7,49 3,66 1,06/5,80/6,00 1,93 3,01 0,74/4,70/5,33 2,95 4,6 62 42 50 230-1-50 106 908 821 326 61
1,34/7,20/8,00 1,84 3,91 4,20 2,00 2,10 1,00/7,80/8,40 3,95 1,34/7,40/8,00 2,34 3,16 0,50/5,80/5,80 2,95 4,4 64 43 50 230-1-50 107 908 821 326 71
3,60/11,90/13,45 3,04 3,91 7,40 2,96 2,50 5,88/13,5/16,12 3,67 3,47/12,95/12,90 4,30 3,01 3,83/10,20/11,70 2,96 4,3 67 46 55 230-1-50 112 908 1.363 326 105
3,18/14,5/16,49 3,57 4,06 8,00 3,20 5,72/16,0/17,31 3,81 3,07/14,0/15,92 4,36 3,75/13,0/13,55 2,91 4,4 68 47 30 115 908 1.363 326 130 230-1-50 3,21
kW kW kW
(**) Reference for the tax credit for the French market. (***) Energy indices calculated in compliance with that envisaged by EN 14511:2004 Standard, in the conditions prescribed by the Finance Act, Italian market.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Air: 7C D.B. - 6C W.B. - Water: 30/35C. Air: -7C D.B. - Water: 35C. With the same water ow rate as condition . Air: 35 D.B. - Water: 23/18C. Air: 7C D.B. - 6C W.B. - Water: 40/45C. Air: 35 D.B. - Water: 12/7C. 5 m from the unit in free eld (Q = 2). The weight refers to the unit in its most complete form. ESEER (European Seasonal EER) - Average European seasonal eciency.
2,50
Radiant systems
THAIY MODEL
104
106
107
112
115
TCAEY 105111
Cooling capacity: 5.511.1 kW
Packaged air-cooled water chillers with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch. Air side heat exchanger: nned coil exchanger, with copper pipes and aluminium ns or coil with aluminium micro-channel pipes, complete with protection grille. Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. Structure: in galvanised and painted sheet steel.
Soft-start device (for models with 230 V power supply). -10C condensing control. Low pressure switch. Digital input for double set-point. 4-20 mA analogue input for shifting set-point.
Models
PUMP unit
Pump assembly complete with: circulator pump, expansion tank with membrane, manual air bleed valve, safety valve.
External air temperature probe for set-point compensation. Antivibration rubber mountings. -10C condensing control. Water lter. Low pressure switch. Antifreeze electric heater on the buer tank. Remote keyboard with display. Clock card. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management.
TANK&PUMP unit
Pump assembly complete with: water buer tank, circulation pump, expansion tank with membrane, manual air bleed valve, automatic air bleed valve, safety valve.
COOLING ONLY
OUTDOOR INSTALLATION
25
E.E.R. E.S.E.E.R. E.S.E.E.R.+ Absorbed power (*) Cooling capacity (radiating) E.E.R. (radiating) Absorbed power (radiating) (*) Sound pressure level Scroll/step compressor Circuits Water buffer tank content Circulation pump available head pressure Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height PUMP H - Height TANK & PUMP P - Depth Weight mm mm mm mm kg kW dB(A) no. no. l kPa kW kW
2,74 3,15 3,50 2,00 7,5 3,71 2,02 46 1/1 1 19 55 / 85 230-1-50 105 990 905 905 380 131
2,58 2,77 3,07 2,67 9,3 3,54 2,61 47 1/1 1 19 55 / 86 230-1-50 400-3+N-50 107 990 905 905 380 133
2,66 3,16 3,50 3,32 12,2 3,56 3,43 47 1/1 1 30 65 / 84 230-1-50 400-3+N-50 109 990 1.085 1.295 380 157
2,62 / 2,62 3,11 / 3,15 3,42 / 3,49 4,12 / 4,25 15,2 / 15,5 4,30 / 4,39 47 1/1 1 30 230-1-50 400-3+N-50 111 990 1.085 1.295 166 380 61 /75
V-ph-Hz
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Air: 35C - Water: 12/7C. Air: 35C - Water: 23/18C. 5 m from the unit in free eld (Q = 2). The weight refers to the unit in its most complete form.
ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software. (*) Unit without circulation pump.
3,54 / 3,54
kW
5,5
6,9
8,8
10,8 / 11,1
TCAEY MODEL
105
107
109
111
THAEY 105111 NF
Heating capacity: 5.811.9 kW
Compact and Plug&Play units Operation with outdoor air down to 15C
Packaged air-cooled reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch. Air side heat exchanger: featuring nned coil with copper pipes and aluminium ns with hydrophilic treatment, complete with protection grille. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. Structure: in galvanised and painted sheet steel, complete with condensation drain pan and unit base antifreeze electric heater.
TANK&PUMP unit
Pump assembly complete with: water buer tank, circulation pump, expansion tank with membrane, manual air bleed valve, automatic air bleed valve, safety valve.
Soft-start device (for models with 230 V power supply). Crankcase heater compressor. Digital input for double set-point. 4-20 mA analogue input for shifting set-point.
3-way valve for the production of hot water. Additional electric heater for heat pump, managed by regulation. External air temperature probe for set-point compensation. Antivibration rubber mountings. Water lter. Antifreeze electric heater on the buer tank. Remote keyboard with display. Clock card. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for monitoring and remote management of the unit.
Models
PUMP unit
Pump assembly complete with: circulation pump, expansion tank with membrane, manual air bleed valve, safety valve.
HEAT PUMP
OUTDOOR INSTALLATION
27
C.O.P. Absorbed power (*) Cooling capacity E.E.R. E.S.E.E.R. E.S.E.E.R.+ Absorbed power (*) Heating capacity Absorbed power C.O.P. (**) Heating capacity Absorbed power C.O.P. Cooling capacity E.E.R. Sound power level / Sound pressure Scroll/step compressor Water buffer tank content Circulator pump available head pressure Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height PUMP H - Height TANK&PUMP P - Depth Weight mm mm mm mm kg dB(A) dB(A) no. l kPa V-ph-Hz kW kW kW kW kW kW kW kW
2,74 2,13 5,50 2,74 3,15 3,50 2,00 5,95 1,75 3,40 3,61 1,72 2,10 7,50 3,71 70 46 1/1 19 55 230-1-50 105 990 905 905 380 141
2,65 2,80 6,90 2,58 2,77 3,07 2,67 7,76 2,16 3,59 4,66 2,20 2,12 8,90 3,27 72 47 1/1 19 55 230-1-50 / 400-3+N-50 107 990 905 905 380 143
2,76 3,43 8,80 2,66 3,16 3,50 3,32 9,54 2,78 3,43 5,93 2,82 2,10 12,10 3,53 72 47 1/1 30 65/84 230-1-50 / 400-3+N-50 109 990 1.085 1.295 380 167
2,51/2,60 4,60/4,59 10,8/11,1 2,62/2,62 3,11/3,15 4,12/4,25 12,06/12,47 3,47/3,47 3,48/3,59 7,46/7,44 2,13/2,11 14,5/14,8 3,20/3,27 72 47 1/1 61/75 230-1-50 / 400-3+N-50 111 990 1.085 1.295 380 176 30 3,50/3,52
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Air: 7C D.B. - 6C W.B. - Water: 40/45C. Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B. - Water: 30/35C. Air: -7C D.B. - Water: 35. Same water ow rate of condition . Air: 35C - Water: 23/18C. 5 m from the unit in free eld (Q = 2). The weight refers to the unit in its most complete form.
ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software. (*) Unit without circulation pump. (**) Reference for the tax credit for the French market.
3,42 / 3,49
Heating capacity
kW
5,80
7,43
9,46
11,52/11,97
THAEY NF MODEL
105
107
109
111
THAEY 115127 NF
Heating capacity: 16.830.7 kW
Operation with outdoor air down to 15C Plug&Play unit with integrated hydraulic module
Packaged air-cooled reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas.
Construction features
Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater for mod. 127. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch. Air side heat exchanger: featuring nned coil with copper pipes and aluminium ns with hydrophilic treatment, complete with protection grille. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control, iDRHOSS compatible with Adaptive Function Plus logic, with set-point variation based on the actual thermal load. Structure: in galvanised and painted sheet steel, complete with condensation drain pan and unit base antifreeze electric heater.
TANK&PUMP unit
Pump assembly complete with: inertial water buer tank, circulation pump or electric circulation pump, expansion tank with membrane, manual air bleed valve, automatic air bleed valve, safety valve and pressure gauge.
Soft-start device. Silenced installation. Antifreeze electric heater on the buer tank. Crankcase heater compressor (mod. 115124). Digital input for double set-point. 4-20 mA analogue input for shifting set-point.
Models
PUMP unit
Pump assembly complete with: circulation pump or electric circulation pump, expansion tank with membrane, manual air bleed valve, safety valve, pressure gauge.
3-way valve for the production of hot water, managed by regulation. Additional electric heater for heat pump, managed by regulation. External air temperature probe for set-point compensation. Antivibration rubber mountings. Water lter. Remote keyboard with display. Clock card. Serial interfaces for the BMS connection or for managing the unit within the scope of a Rhoss heat pump system (proprietary protocol, Modbus RTU, LonWorks). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. GSM 900/1800 modem kit for remote unit management. Rhoss supervision system for unit monitoring and remote management.
HEAT PUMP
OUTDOOR INSTALLATION
29
Heating capacity Absorbed power C.O.P. (**) Heating capacity Absorbed power C.O.P. Cooling capacity E.E.R. Fan coil systems Heating capacity Absorbed power (*) C.O.P. Cooling capacity E.E.R. E.S.E.E.R. E.S.E.E.R.+ Sound power level / Sound pressure level / Silenced version sound pressure level Scroll/step compressor Water buffer tank content Available head pressure of circulator pump/standard pump Electrical supply DIMENSIONS AND WEIGHTS L - Width PUMP L - Width TANK&PUMP H - Height P - Depth Weight
kW kW kW kW kW
17,92 4,94 3,62 11,62 5,01 2,32 23,40 3,30 17,90 6,10 2,93 17,40 2,70 3,11 3,42 73 50 46 1/1 35 63/130 400-3+N-50 117 1.230 1.522 1.090 580 225
23,60 6,52 3,62 15,27 6,63 2,30 30,50 3,43 23,66 8,06 2,94 22,30 2,81 3,44 3,82 78 52 49 1/1 45 65/131 400-3+N-50 122 1.230 1.522 1.280 600 278
25,51 7,35 3,47 17,15 7,57 2,26 31,90 3,13 26,14 8,94 2,92 23,64 2,52 3,09 3,41 78 52 49 1/1 45 68/131 400-3+N-50 124 1.230 1.522 1.280 600 288
31,19 8,16 3,82 20,45 8,27 35,30 3,24 30,69 10,00 26,33 2,61 3,18 3,5 79 53 1/1 45 63/116 400-3+N-50 127 1.535 1.822 1.510 600 320 50 3,07
kW kW kW
(*) Unit without circulation pump. (**) Reference for the tax credit for the French market. NB: the NF PAC certication is valid for hydraulic installations with a circulation pump (P0) and with a circulation pump and a water buer tank (ASP0).
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Air: 7C D.B. - 6C W.B. - Water: 30/35C. Air: -7C D.B. - Water: 35C. With the same water ow rate as condition . Air: 35 D.B. - Water: 23/18C. Air: 7C D.B. - 6C W.B. - Water: 40/45C. Air: 35 D.B. - Water: 12/7C. 5 m from the unit in free eld (Q = 2). The weight refers to the unit in its most complete form.
ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software.
2,47
Radiant systems
THAEY NF MODEL
115
117
122
124
127
Operation with outdoor air down to 15C Hot water up to 60C Standard soft-start device for models with a single-phase power supply
Packaged air-cooled reversible heat pumps for very hot water production, with axial fans. Range with hermetic Scroll compressors and R407C refrigerant gas.
Construction features
Compressor: high eciency, hermetic rotary scroll compressor complete with thermal protection, crankcase heater and soft-start device for single-phase models. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch. Air side heat exchanger: featuring nned coil with copper pipes and aluminium ns with hydrophilic treatment, complete with protection grille. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control, iDRHOSS compatible with Adaptive Function Plus logic, with set-point variation based on the actual thermal load. Structure: in galvanised and painted sheet steel, complete with condensation drain pan and unit base antifreeze electric heater.
TANK&PUMP unit
Pump assembly complete with: water buer tank, circulation pump or electric circulation pump, expansion tank with membrane, air bleed valves, safety valve and drain valve.
Soft-start device (for models with 400 V power supply, as standard for 230 V models). Silenced installation. Water buer tank antifreeze electric heater Digital input for double set-point. 4-20 mA analogue input for shifting set-point.
Models
Without pump assembly and water buer tank. Pump assembly complete with: circulation pump or electric circulation pump, expansion tank with membrane, manual air bleed valve and safety valve.
3-way valve for the production of hot water, managed by regulation. Additional electric heater for heat pump, managed by regulation. External air temperature probe for set-point compensation. Water lter. Antivibration rubber mountings. Remote keyboard with display. Clock card. Serial interfaces for the BMS connection or for managing the unit within the scope of a Rhoss heat pump system (proprietary protocol, Modbus RTU, LonWorks). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. GSM 900/1800 modem kit for remote unit management. Rhoss supervision system for unit monitoring and remote management.
HEAT PUMP
OUTDOOR INSTALLATION
31
Heating capacity Absorbed power C.O.P. Heating capacity Absorbed power C.O.P. Heating capacity Absorbed power C.O.P. Heating capacity Absorbed power C.O.P. Cooling capacity E.E.R. E.S.E.E.R. E.S.E.E.R.+ E.S.E.E.R. + Radiant systems Heating capacity Absorbed power (*) C.O.P. C.O.P. (**) Cooling capacity Absorbed power (*) E.E.R. Sound power level \ Sound pressure level \ Silenced version sound pressure level Scroll/step compressor Water buffer tank content Electrical supply DIMENSIONS AND WEIGHTS L - Width PUMP/STANDARD L - Width TANK&PUMP H - Height PUMP/STANDARD H - Height TANK&PUMP P - Depth Weight
kW kW kW kW kW kW kW kW kW
8,70 3,15 2,76 5,70 3,10 1,84 8,46 3,82 2,21 6,17 3,56 1,73 8,50 2,86 3,45 3,82
13,84 4,60 3,01 8,83 4,46 1,98 14,04 5,49 2,56 10,20 5,50 1,85 11,10 2,39 3,51 3,89 14,26 3,44 4,14 3,76 15,80 4,40 3,59 73,0 50 46 1/1 35 61/150 230-1-50 / 400-3+N-50 113 1.230 1.522 1.090 1.090 580 217
19,10 6,30 3,03 11,35 5,57 19,84 7,33 2,71 12,90 6,46 15,50 2,39 3,25 3,61 19,70 4,17 3,91 22,00 6,25 3,52 77,6 52 49 1/1 45 60/151 400-3+N-50 119 1.230 1.522 1.280 1.280 600 267 2,00
kW kW
11,20 3,21 3,49 71,0 47 45 1/1 30 37/86 230-1-50 / 400-3+N-50 110 990 990 1.085 1.295 380 189
TERMINAL UNITS
In the following conditions: Air: 7C D.B. - 6C W.B. - Water: 40/45C. Air: -7C D.B. - Water: 45C. With the same water ow rate as condition . Air: 7C D.B. - 6C W.B. - Water: 47/55C. Air: -7C D.B. - Water: 55C. With the same water ow rate as condition . Air: 35 D.B. - Water: 12/7C. Air: 7C D.B. - 6C W.B. - Water: 30/35C. Air: 35 D.B. - Water: 23/18C. 5 m from the unit in free eld (Q = 2). The weight refers to the unit in its most complete form.
ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software. (*) Unit without circulation pump. (**) Reference for the tax credit for the French market. NB: NF PAC certication is valid for all models with hydraulic installations with a circulation pump (P0) and with a circulation pump and a water buer tank (ASP0) with the exception of model 110 with 400V power supply.
SYSTEM ACCESSORIES
CONDENSING UNITS
4,72
2,04
110
113
119
TCAEY-THAEY 115238
Air-cooled water chillers and reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas.
Construction features
Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater for mod. 127238. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch. Air side heat exchanger: featuring nned coil with copper pipes and aluminium ns, complete with protection grille. Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. Structure: in galvanised and painted sheet steel, complete with condensation drain pan.
Soft-start device. Silenced installation. -10C condensation control. Antifreeze electric heater on the buer tank. Crankcase heater compressor (mod. 115124). Unit base antifreeze electric heater for operation in heat pump mode at low outdoor air temperatures (mod.124). 115130). Desuperheater 15% (mod. 133-233). 100% heat recovery (mod. 133-233). Pump with increased head pressure (mod. 133238)or circulator with low head pressure (mod. 115233). Pump with increased head pressure (mod. 133238)or circulator with low head pressure (mod. 115233) + buer tank. Digital input for double set-point 4-20 mA analogue input for shifting set-point.
Models
TCAEY: unit designed for cooling only. THAEY: heat pump unit.
Without pump assembly and water buer tank. Pump assembly complete with: circulation pump, expansion tank with membrane, manual bleed valve and safety valve, pressure gauge.
Pump assembly complete with: inertial water buer tank, circulation pump, expansion tank with membrane, manual air bleed valve, automatic air bleed valve, safety valve, pressure gauge.
Antivibration rubber mountings. -10C condensation control. Water lter. 3-way valve for the production of hot water (mod. 115133). External air temperature probe for set-point compensation. Additional electric heater for heat pump, managed by regulation. Remote keyboard with display. Clock card Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management.
COOLING ONLY
HEAT PUMP
OUTDOOR INSTALLATION
33
E.E.R. E.S.E.E.R. E.S.E.E.R.+ Absorbed power (*) Nominal heating capacity C.O.P. Absorbed power (*) E.E.R. (EN 14511:2004) (***) C.O.P. (EN 14511:2004) (***) C.O.P. (**) Sound pressure level Silenced version sound pressure level Scroll/step compressor Circuits Water buffer tank content Electrical supply DIMENSIONS AND WEIGHTS L - Width STANDARD L - Width PUMP L - Width TANK & PUMP H - Height P - Depth Weight TCAEY Weight THAEY mm mm mm mm mm kg kg dB(A) dB(A) no. no. l kW kW kW
2,76 3,15 3,49 5,6 16,8 3,05 5,5 3,74 50 46 1/1 1 35 74/147 115 1.230 1.522 1.090 580 210 215
2,67 3,11 3,42 6,5 17,9 2,94 6,1 3,77 50 46 1/1 1 35 63/130 117 1.230 1.522 1.090 580 220 225
2,76 3,44 3,82 8,2 23,9 3,02 7,9 3,93 52 49 1/1 1 45 64/130 122 1.230 1.522 1.280 600 270 278
2,62 3,09 3,41 9,3 26,1 2,92 8,9 3,76 52 49 1/1 1 45 66/125 124 1.230 1.522 1.280 600 280 288
2,59 3,18 3,50 10,4 30,7 3,07 10,0 3,94 53 50 1/1 1 45 61/110 127 1.535 1.822 1.510 695 310 320
2,44 2,89 3,20 11,9 34,4 3,10 11,1 3,86 53 50 1/1 1 45 57/105 130 1.535 1.822 1.510 695 370 380
2,56 2,85 3,19 13,3 39,1 2,94 13,3 3,67 54 51 1/1 1 80 65/134 133 1.660 1.660 1.660 1.570 1.000 450 460
2,64 3,67 4,11 12,3 37,5 3,05 12,3 3,33 4,00 3,96 54 51 2/2 1 80 69/134 233 1.660 1.660 1.660 1.570 1.000 465 475
3,06 3,69 4,12 12,7 41,7 12,8 4,03 4,26 4,16 54 2/2 1 150 130 238 2.260 2.260 1.570 1.000 625 645 51
V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 2.260
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B. - Water: 40/45C. 5 m from the unit in free eld (Q = 2). The weight refers to the unit in its most complete form. ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software.
(*) Unit without circulator pump. (**) Reference for the tax credit for the French market. (***) Energy indices for versions with a standard head pump, calculated in compliance with that envisaged by the EN 14511:2004 Standard, in the conditions prescribed by the Finance Act, Italian market.
3,26
kW
15,4
17,4
22,7
24,3
26,9
29,1
34,0
32,5
38,8
TCAEY-THAEY MODEL
115
117
122
124
127
130
133
233
238
TCAEY-THAEY 245265
Air-cooled water chillers and reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas.
Construction features
Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. 3 capacity steps with high eciency at partial loads. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch. Air side heat exchanger: featuring nned coil with copper pipes and aluminium ns, complete with protection grille. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. Structure: in galvanised and painted sheet steel.
Soft-start device. Silenced installation. 15% desuperheater. 100% heat recovery. Refrigerant circuit high and low pressure gauges. Antifreeze electric heater for buer tank and pumps. Digital input for double set-point 4-20 mA analogue input for shifting set-point.
Models
TCAEY: unit designed for cooling only. THAEY: heat pump unit.
PUMP with single or double pump, including an automatic pump in standby, complete with expansion tank, air bleed valve, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions. TANK&PUMP with water buer tank and single or double pump, including an automatic pump in standby, complete with expansion tank, air bleed valve, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions.
External air temperature probe for set-point compensation. Additional electric heater for heat pump, managed by regulation. Antivibration rubber mountings. Water lter. Remote keyboard with display. Clock card Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management.
COOLING ONLY
HEAT PUMP
OUTDOOR INSTALLATION
35
E.E.R. E.S.E.E.R. E.S.E.E.R.+ Absorbed power (*) Nominal heating capacity C.O.P. Absorbed power (*) E.E.R. (EN 14511:2004) (***) C.O.P. (EN 14511:2004) (**) (***) Sound pressure level Silenced version sound pressure level Scroll/step compressor Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCAEY Weight THAEY TANK & PUMP TCAEY-THAEY MODEL Nominal flow Water tank content Pump available head pressure Pump P1 Pump P2 PUMP TCAEY-THAEY MODEL Nominal flow Pump available head pressure Pump P1 Pump P2 KPa KPa l/h KPa KPa l/h l mm mm mm kg kg dB(A) dB(A) no. no. V-ph-Hz kW kW kW
2,55 3,78 4,38 17,4 47,8 2,89 16,6 3,36 3,93 56 53 2/3 1 400-3+N-50 245 2.260 1.570 1.000 725 745
2,60 4,31 4,98 19,7 55,8 3,00 18,6 3,34 3,94 56 53 2/3 1 400-3+N-50 250 2.260 1.570 1.000 750 770
2,68 4,38 5,04 22,1 62,2 3,04 20,5 3,39 3,93 57 54 2/3 1 400-3+N-50 260 2.260 1.570 1.000 775 795
2,67 4,03 4,72 24,0 67,9 23,3 3,44 3,97 57 54 1 400-3+N-50 265 2.260 1.570 1.000 840 820 2/3
(*) Unit without pump. (**) Reference for the tax credit for the French market. (***) Energy indices calculated in compliance with that envisaged by EN 14511: 2004 Standard, in the conditions prescribed by the Finance Act, Italian market.
TERMINAL UNITS
SYSTEM ACCESSORIES
In the following conditions: Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B. - Water: 40/45C. 5 m from the unit in free eld (Q = 2). The weight refers to the unit in its most complete form. ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software.
CONDENSING UNITS
2,91
kW
44,2
51,3
59,2
64,0
TCAEY-THAEY MODEL
245
250
260
265
Y-M.I.C.H. Range
36
TCAIY-THAIY 124-150
Cooling capacity: 23.848.5 kW - Heating capacity: 27.354.3 kW
IN
IN
ER T ER
Air-cooled water chillers and reversible heat pumps with axial fans. Range with hermetic scroll compressors, inverters and R410A refrigerant gas.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection and crankcase heater, activated by Inverter. Expansion valve: electronic. Water side heat exchanger: stainless steel plate exchanger closed cell polyurethane foam rubber insulation, complete with antifreeze heater and water ow dierential pressure switch. Air side heat exchanger: featuring nned coil with copper pipes and aluminium ns, complete with protection grille. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control, iDRHOSS compatible Structure: in galvanised and painted sheet steel, complete with condensation drain pan for THAIY 124.
With tank and pump. With tank, pump and pump in stand-by (for model 150 only) . Pump assembly complete with: inertial water buer tank, single or twin circulation pump of which one in stand-by with automatic activation in the event of an alarm (only for mod. 150), expansion tank with membrane, manual air bleed valve, safety valve, water drain tap and pressure gauge. The pumps are available in the low and high pressure versions (mod. 150).
Buer tank and/or pumps antifreeze electric heater Unit base antifreeze electric heater for operation in heat pump mode at low outdoor air temperatures (mod.124). 124). Refrigerant circuit high and low pressure gauges (mod. 150). Digital input for double set-point 4-20 mA analogue input for shifting set-point.
Models
TCAIY: unit designed for cooling only. THAIY: heat pump unit.
Without pump assembly and buer tank (for mod. 150). With pump. With pump and pump in stand-by (model 150 only). Pump assembly complete with: single or twin circulation pump of which one in stand-by with automatic activation in the event of an alarm (only for mod. 150), expansion tank with membrane, manual air bleed valve, safety valve, water drain tap and pressure gauge. The pumps are available in the low and high pressure versions (mod. 150).
3-way valve for the production of hot water. Antivibration rubber mountings. Water lter. Remote keyboard with display. Clock card Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management.
COOLING ONLY
HEAT PUMP
OUTDOOR INSTALLATION
37
E.E.R. E.S.E.E.R. Absorbed power (*) Nominal heating capacity C.O.P. Absorbed power (*) E.E.R. (EN 14511:2004) (***) C.O.P. (EN 14511:2004) (***) C.O.P. (**) Sound pressure level Water buffer tank content Available nominal head pressure of pump Inverter scroll compressor Modulating cooling capacity range Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCAIY Weight THAIY mm mm mm kg kg no. V-ph-Hz dB(A) l kPa no. kW kW kW
2,53 3,96 9,42 27,3 2,95 9,28 52 45 129 1 30-100% 1 400-3+N-50 124 1.522 1.280 600 330 338 (*) Unit without pump. (**) Reference for the tax credit for the French market. (***) Energy indices calculated in compliance with that envisaged by EN 14511: 2004 Standard, in the conditions prescribed by the Finance Act, Italian market.
2,63 4,11 18,4 54,3 3,13 3,04 3,64 3,64 55 150 1 30-100% 1 400-3+N-50 150 2.260 1.000 625 645 1.570 114
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B. - Water: 40/45C. 5 m from the unit in free eld (Q = 2). ESEER (European Seasonal EER) - Average European seasonal eciency.
17,40
kW
23,8
48,5
124
150
TCAEY-THAEY 2702160
Cooling capacity: 67161 kW - Heating capacity: 79175 kW
TCAEBY 2160
Air-cooled water chillers and reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection and crankcase heater. 2 or 3 capacity steps depending on the models with high eciency at partial loads. Water side heat exchanger: stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water ow dierential pressure switch. Air side heat exchanger: nned coil exchanger, with copper pipes and aluminium ns. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous regulation of fan rotation speed (TCAEBY excluded). Control: microprocessor electronic control iDRHOSS compatible, with Adaptive Function Plus logic for connection with the main BMS on the market (MODBUS RTU, LON). Structure: load-bearing structure in galvanised and painted sheet steel with polyester powder coating. The unit is also complete with: - compressor and fan thermal overload switches.
Models
TCAEBY: standard unit designed for cooling only. TCAETY: high temperature/eciency unit designed for cooling only. TCAESY: silenced unit designed for cooling only. TCAEQY: supersilenced unit designed for cooling only. THAETY: heat pump unit. THAESY: silenced heat pump unit.
Versions
B - Standard version (TCAEBY). T - High temperature/eciency version with larger coil surface (TCAETY-THAETY). S - Silenced version complete with soundproofed compressor compartment, lower fan speed and larger coil surface (TCAESYTHAESY). Q - Supersilenced version complete with soundproofed compressor compartment, super-low fan speed and larger coil surface (TCAEQY).
PUMP with single or double pump, including an automatic pump in standby, complete with expansion tank, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions. TANK&PUMP with built-in buer tank from 250 to 450 litres and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. Desuperheater. 100% heat recovery. Electronic expansion valve. -10C condensation control (TCAEBY only). Power factor correction capacitors (cos > 0.91). Soft starter. Refrigerant circuit high and low pressure gauges. Metal lters or coil protection grilles. Copper/copper or copper/pre-painted aluminium coils. Digital input for double set-point 4-20 mA analogue input for shifting set-point. Evaporator antifreeze heater, buer tank, pumps and heat exchangers for heat recovery if present. Serial interface for connection with external BMS.
Antivibration rubber mountings. Remote keyboard with display. Clock card GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management. Rhoss sequencer for the integrated management of several water chillers.
COOLING ONLY
HEAT PUMP
OUTDOOR INSTALLATION
39
E.E.R. Absorbed power TCAETY-TCAESY-TCAEQY MODEL Nominal cooling capacity Nominal cooling capacity Nominal cooling capacity E.E.R. E.E.R. E.E.R. E.S.E.E.R. E.S.E.E.R.+ Absorbed power Absorbed power Absorbed power THAETY-THAESY MODEL Nominal heating capacity Nominal heating capacity C.O.P. C.O.P. Nominal cooling capacity Nominal cooling capacity Absorbed power Absorbed power E.E.R. (EN 14511:2004) (***) C.O.P. (EN 14511:2004) (***) TCAEY-THAEY MODEL Sound pressure level TCAEBY Sound pressure level TCAETY-THAETY Sound pressure level TCAESY-THAESY Sound pressure level TCAEQY Sound power level TCAEBY Sound power level TCAETY-THAETY Sound power level TCAESY-THAESY Sound power level TCAEQY Scroll/step compressor Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width version B L - Width version T - S - Q H - Height version B H - Height version T - S - Q P - Depth version B P - Depth version T - S - Q Weight TCAEBY Weight TCAETY-TCAESY-TCAEQY Weight THAETY-THAESY mm mm mm mm mm mm kg kg kg dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) no. no. V-ph-Hz kW kW kW kW kW kW kW kW kW kW kW kW kW
2,65 25,5 270 70,4 70,4 67,0 2,98 2,98 2,70 4,32 4,99 23,6 23,6 24,8 270 79,0 79,0 3,36 3,36 69,4 69,4 23,5 23,5 3,44 4,26 270 53 50 48 46 82 76 74 72 2/3 1 400-3+N-50 270 2.650 3.150 1.700 1.520 1.210 1.210 685 745 810
2,69 28,0 280 79,5 79,5 75,0 2,99 2,99 2,85 4,37 5,06 26,6 26,6 26,3 280 86,0 86,0 3,44 3,44 77,7 77,7 25,0 25,0 3,49 4,34 280 53 51 49 47 82 77 75 73 2/2 1 400-3+N-50 280 2.650 3.150 1.700 1.520 1.210 1.210 725 765 830
2,56 32,4 290 88,0 88,0 82,5 2,90 2,90 2,62 4,35 5,04 30,3 30,3 31,5 290 96,0 96,0 3,29 3,29 85,2 85,2 29,2 29,2 3,30 4,17 290 53 51 49 47 82 77 75 73 2/3 1 400-3+N-500 290 2.650 3.150 1.700 1.520 1.210 1.210 870 910 975
2,69 35,7 2100 101,2 101,2 95,0 2,90 2,90 2,73 4,32 4,99 34,9 34,9 34,8 2100 111,0 111,0 3,34 3,34 99,3 99,3 33,2 33,2 3,32 4,22 2100 55 52 50 48 84 78 76 74 2/3 1 400-3+N-50 2100 3.150 3.150 1.700 1.520 1.210 1.210 945 980 1045
2,72 40,6 2115 114,5 108,0 101,0 2,93 2,67 2,34 4,37 5,07 39,1 40,4 43,2 2115 122,0 120,0 3,21 3,22 111,0 107,2 38,0 37,3 3,34 4,04 2115 61 55 52 49 90 84 81 78 2/3 1 400-3+N-50 2115 3.150 3.250 1.730 2.000 1.210 1.520 1.020 1.130 1.215
2,64 45,6 2130 126,0 119,0 108,0 2,91 2,67 2,30 4,31 4,96 43,3 44,6 47,0 2130 139,0 135,0 3,31 3,31 123,8 118,5 42,0 40,8 3,33 4,14 2130 61 55 52 49 90 84 81 78 2/2 1 400-3+N-50 2130 3.150 3.250 1.730 2.000 1.210 1.520 1.040 1.195 1.285
2,66 52,1 2145 143,0 136,0 125,0 2,90 2,63 2,32 4,29 4,94 49,3 51,7 53,9 2145 157,0 154,0 3,22 3,25 141,3 135,6 48,8 47,4 3,30 4,01 2145 61 56 53 50 90 85 82 79 2/3 1 400-3+N-50 2145 3.150 3.250 1.730 2.000 1.210 1.520 1.100 1.225 1.315
2,61 59,4 2160 161,0 151,0 2,90 2,60 2,20 4,26 4,91 58,1 62,6 2160 175,0 170,0 3,21 159,8 150,2 54,5 53,0 3,29 4,02 2160 62 56 53 50 91 85 82 79 2/2 1 400-3+N-50 2160 3.450 3.250 1.730 2.000 1.210 1.520 1.160 1.390 1.290 3,21 55,5
In the following conditions: Air: 35C - Water: 12/7C Air: 7C D.B. - 6C W.B.- Water: 40/45C. At 10 m from the unit in free eld (Q = 2), coil side. Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. Weight refers to the non-accessorised unit when empty. ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software. (***) Energy indices for THAETY versions, calculated in compliance with that envisaged by EN 14511: 2004 Standard, in the conditions prescribed by the Finance Act, Italian market. TCAESY-THAESY silenced versions. TCAEQY super-silenced versions.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
138,2
kW
67,5
75,3
83,0
96,0
110,5
120,5
138,5
155,0
TCAEBY MODEL
270
280
290
2100
2115
2130
2145
2160
TCAEY-THAEY 41604320
Cooling capacity: 145337 kW - Heating capacity: 167353 kW
GREEN LINE
NOVELTIES
High performance range with extended working limits ESEER up to 4.29 Compact version B for replacement markets
TCAETY 4320 with coil protection grille accessory TCAEBY 4200 with the silenced conguration accessory
Air-cooled water chillers and reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection and crankcase heater. 4 capacity steps with high eciency at partial loads. Water side heat exchanger: stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water ow dierential pressure switch. Air side heat exchanger: nned coil exchanger, with copper pipes and aluminium ns. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous regulation of fan rotation speed (S - Q versions only). Control: microprocessor electronic control iDRHOSS compatible, with Adaptive Function Plus logic for connection with the main BMS on the market (MODBUS RTU, LON). Structure: load-bearing structure in galvanised and painted sheet steel with polyester powder coating. The unit is also complete with: - compressor and fan thermal overload switches.
Versions
B - Standard version (TCAEBY). T - High temperature/eciency version with larger coil surface (TCAETYTHAETY). S - Silenced version complete with soundproofed compressor compartment, lower fan speed and larger coil surface (TCAESY-THAESY). Q - Supersilenced version complete with soundproofed compressor compartment, super-low fan speed and larger coil surface (TCAEQY).
PUMP with single or double pump, including an automatic pump in standby, complete with expansion tank, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions. TANK&PUMP with 750-litre built-in buer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. Desuperheater (TCAEBY excluded). 100% heat recovery (TCAEBY excluded). Electronic expansion valve. -10C condensation control (as per standard in S - Q versions). Power factor correction capacitors (cos > 0.91). Soft starter. Soundproofed compressor box (TCAEBY only). Silenced conguration (TCAEBY only). Refrigerant circuit high and low pressure gauges. Metal lters or coil protection grilles (excluding TCAEBY). Copper/copper or copper/pre-painted aluminium coils. Digital input for double set-point 4-20 mA analogue input for shifting set-point. Evaporator antifreeze heater, buer tank, pumps and heat exchangers for heat recovery if present. Serial interface for connection with external BMS.
Models
TCAEBY: standard unit designed for cooling only. TCAETY: high temperature/eciency unit designed for cooling only. TCAESY: silenced unit designed for cooling only. TCAEQY: supersilenced unit designed for cooling only.
Antivibration mountings. Remote keyboard with display. Clock card GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management. Rhoss sequencer for the integrated management of several water chillers.
COOLING ONLY
HEAT PUMP
OUTDOOR INSTALLATION
41
E.E.R. Absorbed power TCAETY-TCAESY-TCAEQY EVO MODEL Nominal cooling capacity Nominal cooling capacity Nominal cooling capacity E.E.R. E.E.R. E.E.R. E.S.E.E.R. E.S.E.E.R.+ Absorbed power Absorbed power Absorbed power THAETY-THAESY EVO MODEL Nominal heating capacity Nominal heating capacity C.O.P. C.O.P. Nominal cooling capacity Nominal cooling capacity Absorbed power Absorbed power TCAEY-THAEY EVO MODEL Sound pressure level TCAEBY Sound pressure level TCAETY-THAETY Sound pressure level TCAESY-THAESY Sound pressure level TCAEQY Sound power level TCAEBY Sound power level TCAETY-THAETY Sound power level TCAESY-THAESY Sound power level TCAEQY Scroll/step compressor Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width version B L - Width TCAETY-TCAESY-TCAEQY L - Width THAETY-THAESY H - Height version B H - Height version T - S H - Height version Q P - Depth version B P - Depth version T - S - Q Weight TCAEBY Weight TCAETY-TCAESY-TCAEQY Weight THAETY-THAESY mm mm mm mm mm mm mm mm kg kg kg dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) no. no. V-ph-Hz kW kW kW kW kW kW kW kW kW kW kW kW kW
2,67 59,2 4160 166 159 145 2,97 2,84 2,35 4,29 4,94 55,9 55,9 61,7 4160 171 167 3,14 3,13 163 157 54,5 53,4 4160 58 54 51 48 90 86 83 80 4/4 2 400-3+N-50 4160 3.130 3.700 3.700 2.135 2.000 2.000 1.190 2.090 1.090 1.600 1.700
2,61 67,9 4180 189 184 173 2,90 2,8 2,58 4,24 4,87 65,1 65,7 67 4180 196 191 3,00 3,01 186 181 65,3 63,4 4180 60 59 54 51 92 91 86 83 4/4 2 400-3+N-50 4180 3.130 3.700 3.700 2.135 2.030 2.000 1.190 2.090 1.375 2.000 2.050
2,62 76,3 4200 210 200 190 2,87 2,71 2,36 4,17 4,79 73,2 73,9 80,5 4200 227 221 3,08 3,12 207 200 73,7 70,8 4200 60 59 54 51 92 91 86 83 4/4 2 400-3+N-50 4200 3.130 3.700 4.800 2.135 2.030 2.000 1.190 2.090 1.500 2.000 2.160
2,63 86,7 4230 234 224 222 2,86 2,71 2,58 4,17 4,79 81,8 82,8 86,2 4230 248 240 3,04 3,07 231 220 81,5 78,3 4230 62 60 55 52 94 92 87 84 4/4 2 400-3+N-50 4230 4.090 4.800 4.800 2.135 2.030 2.000 1.190 2.090 1.670 2.200 2.250
2,62 97,4 4260 266 256 239 2,89 2,86 2,46 4,23 4,91 92,2 89,6 97,1 4260 281 274 3,04 3,08 264 255 92,4 89 4260 62 61 57 53 94 93 89 85 4/4 2 400-3+N-50 4260 4.090 4.800 4.800 2.135 2.030 2.000 1.190 2.090 1.725 2.350 2.450
2,61 112,1 4290 303 292 272 2,86 2,71 2,36 4,2 4,88 105,9 107,8 115,2 4290 318 312 3,01 3,10 301 288 105,7 100,8 4290 63 61 57 53 95 93 89 85 4/4 2 400-3+N-50 4290 5.050 4.800 4.800 2.135 2.030 2.000 1.190 2.090 2.015 2.400 2.550
2,62 124,1 4320 337 321 2,80 2,65 4,15 4,81 121,3 4320 353 344 3,01 334 317 117,4 112,4 4320 63 61 57 95 93 89 4/4 2 400-3+N-50 4320 5.050 4.800 4.800 2.135 2.030 1.190 2.090 2.150 2.600 2.450 3,06 120,5
ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software. TCAESY-THAESY silenced versions. TCAEQY super-silenced versions.
TERMINAL UNITS
In the following conditions: Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B.- Water: 40/45C. At 10 m from the unit in free eld (Q = 2). Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. Weight refers to the non-accessorised unit when empty.
SYSTEM ACCESSORIES
CONDENSING UNITS
kW
158
177
200
228
255
293
325
4160
4180
4200
4230
4260
4290
4320
TFAEY-TGAEY 41604320
Cooling capacity: 170-361 kW
Availability of NO GLYCOL version Plug&Play range Software for estimate of energy saving
Air-cooled water chillers in Free-Cooling mode (TFAEY) and Free-Cooling NO-GLYCOL mode (TGAEY) with axial fans. Range with hermetic Scroll compressors and R410A refrigerant.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection and crankcase heater. 4 capacity steps with high eciency at partial loads. Water side heat exchanger (evaporator): stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water ow dierential pressure switch (TFAEY) or ow switch (TGAEY). Heat exchanger (water-water) in the Free-Cooling NO-GLYCOL mode: stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water ow dierential pressure switch. Air side heat exchanger (condenser): nned coil exchanger, with copper pipes and aluminium ns. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control iDRHOSS compatible, with Adaptive Function Plus logic for connection with the main BMS on the market (MODBUS RTU, LON). Structure: load-bearing structure in galvanised and painted sheet steel with polyester powder coating. The unit is also complete with: - compressor and fan thermal overload switches; - modulating water side 3-way valve.
Versions
T - High eciency version (TFAETY-TGAETY). S - Silenced version complete with soundproofed compressor compartment, lower fan speed (TFAESY-TGAESY).
Models
TFAETY: high eciency unit in Free-Cooling mode. TFAESY: silenced unit in Free-Cooling mode. TGAETY: high eciency unit in Free-Cooling NO-GLYCOL mode. TGAESY: silenced unit in Free-Cooling mode NO-GLYCOL.
PUMP with single or double pump, including an automatic pump in standby complete with safety valve. The pumps are available in the low or high pressure versions. Electronic expansion valve. Power factor correction capacitors (cos > 0.91). Soft starter. Refrigerant circuit high and low pressure gauges. Metal lters or coil protection grilles. Copper/copper or copper/pre-painted aluminium coils. Digital input for double set-point. 4-20 mA analogue input for shifting set-point. Evaporator antifreeze electric heater, pumps if present. Serial interface for connection with external BMS.
Antivibration mountings. Remote keyboard with display. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management.
COOLING ONLY
OUTDOOR INSTALLATION
43
Nominal cooling capacity Nominal cooling capacity E.E.R. E.E.R. Absorbed power Absorbed power FREE-COOLING ON 100% Nominal cooling capacity Nominal cooling capacity E.E.R. E.E.R. Absorbed power Absorbed power Total Free-Cooling temperature Total Free-Cooling temperature TFAETY-TFAESY MODEL Sound pressure level Sound pressure level Sound power level Sound power level Scroll/step compressor Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TFAETY-TFAESY Weight TGAETY-TGAESY
kW kW
202 197 3,4 3,3 59,3 59,3 202 197 24,4 37,8 8 5 1 0,8 4180 63 56 91 86 4/4 2 400-3+N-50 4180 4.800 2.030 2.090 2.820 2.970
224 215 3,3 3,1 68,4 69,2 224 215 26,9 41,4 8 5 0,4 1,5 4200 63 56 91 86 4/4 2 400-3+N-50 4200 4.800 2.030 2.090 2.920 3.070
251 240 3,2 3,1 78,5 77,2 251 240 20,5 31,7 12 7,5 0,7 1,3 4230 65 58 93 88 4/4 2 400-3+N-50 4230 4.800 2.030 2.090 3.020 3.170
286 274 3,3 3,2 85,6 85,2 286 274 22,8 35,2 12 7,5 0,9 1,1 4260 65 59 93 89 4/4 2 400-3+N-50 4260 5.300 2.030 2.090 3.230 3.280
326 312 3,2 3,1 102,0 100,9 326 312 19,5 30,0 16 10 0,4 1,6 4290 66 60 94 90 4/4 2 400-3+N-50 4290 5.300 2.030 2.090 3.380 3.430
kW kW kW kW
361 344 21,5 32,9 10 0,8 3,0 4320 66 60 90 4/4 2 400-3+N-50 4320 5.300 2.030 2.090 3.430 3.480 94 16
5 0,3 1,3 4160 60 55 89 85 4/4 2 400-3+N-50 4160 4.800 2.030 2.090 2.370 2.470
20 15 10 5 0
TFAEY
-20
-15
-10
-5
10
15
20
25
30
35
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Air: 30C - Water: 15/10C - 30% ethylene glycol. Water: 15/10C 30% ethylene glycol. At 10 m from the unit in free eld (Q = 2), coil side. Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. Weight refers to the accessorised unit when empty.
Traditional chiller
kW
117,9
FREE-COOLING OFF
TFAETY-TFAESY MODEL
4160
4180
4200
4230
4260
4290
4320
TCAEY-THAEY 43706660
Cooling capacity: 344661 kW - Heating capacity: 369680 kW
CLASS A Water chillers up to 6 capacity steps ESEER with Adaptive Function Plus up to 5.21
Air-cooled water chillers and reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection and crankcase heater. 4, 5 or 6 capacity steps with high eciency at partial loads. Electronic expansion valve: as standard on all models. Water side heat exchanger: stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water ow dierential pressure switch and Victaulic connections. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: electric axial fans with external rotor, equipped with internal thermal protection and protection grilles (T version); fans with EC motor with continuous adjustment of the rotation speed (Q version). Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - display of refrigerant circuit high/low pressure; - compressor and fan thermal overload switches; - clock card for displaying date/time and machine time band management.
Models
TCAETY: unit designed for cooling only. TCAEQY: supersilenced unit designed for cooling only. THAETY: heat pump unit. THAEQY: supersilenced heat pump unit.
Versions
T - High temperature/eciency version with a larger condensing section (TCAETY-THAETY). Q - Supersilenced version with super-low speed fans with EC motor, high acoustic impedance and soundproofed compressor cover and a larger condensing section (TCAEQY-THAEQY).
Shell and tube evaporator. PUMP with single or double pump, including an automatic pump in standby. The pumps are available in the low or high pressure versions. TANK&PUMP with 1,100-litre built-in buer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. Desuperheater. 100% heat recovery. Thermostat with display for the heat recovery/desuperheater. -10C condensing control. -15C condensation control with fans with EC motor (as per standard in the Q version). Power factor correction capacitors (cos > 0.94). Forced limit of the power consumption. Soundproofed compressor box. Low and high pressure gauges for each refrigerant circuit. Bottom compartment protection grilles. Protection coil grilles. Evaporator antifreeze heater, buer tank and heat exchangers for heat recovery if present. Digital input for double set-point Control of min/max power supply voltage. 4-20 mA analogue input for shifting set-point. Copper/pre-painted aluminium or copper/copper coils. Serial interface for connection with external BMS. Spring antivibration mountings.
Remote keyboard with display. Rhoss sequencer for the integrated management of several water chillers.
COOLING ONLY
HEAT PUMP
OUTDOOR INSTALLATION
45
Nominal cooling capacity E.E.R. E.E.R. E.S.E.E.R. E.S.E.E.R.+ Absorbed power Absorbed power THAETY-THAEQY MODEL Nominal heating capacity Nominal heating capacity C.O.P. C.O.P. Nominal cooling capacity Nominal cooling capacity Absorbed power Absorbed power TCAETY-TCAEQY-THAETY-THAEQY MODEL Sound pressure level Sound pressure level Sound power level Sound power level Scroll/step compressor Circuits Electrical supply DIMENSIONS L - Width H - Height P - Depth
kW
378 3,10 2,89 4,45 4,98 127 131 4400 407 394 3,20 3,05 380 367 127 129 4400 64 53 96 86 4/4 2 400-3-50 4400 4.830 2.430 2.260
421 3,12 2,88 4,39 4,89 142 146 4440 455 437 3,20 3,01 425 410 142 145 4440 64,5 54 97 87 4/4 2 400-3-50 4440 4.830 2.430 2.260
459 3,10 2,87 4,51 5,04 154 160 5470 495 474 3,21 3,00 461 444 154 158 5470 64,5 54 97 87 5/5 2 400-3-50 5470 5.830 2.430 2.260
495 3,12 2,81 4,52 5,12 168 176 6520 530 515 3,21 3,10 499 482 165 166 6520 64,5 54 97 87 6/6 2 400-3-50 6520 5.830 2.430 2.260
557 3,11 2,79 4,49 5,21 188 200 6580 614 595 3,21 3,04 569 550 191 196 6580 64,5 54 97 87 6/6 2 400-3-50 6580 5.830 2.430 2.260
598 3,12 2,82 4,47 5,10 202,5 212 6620 644 626 3,20 3,04 608 590 201 206 6620 65 54 98 88 6/6 2 400-3-50 6620 6.650 2.430 2.260
626 3,12 2,82 4,42 5,00 222 6660 680 657 3,21 634 612 212 219 6660 66 99 89 6/6 2 400-3-50 6660 6.650 2.430 2.260 55 3,00
kW kW kW
356 344 119 123 4370 64 53 96 86 4/4 2 400-3-50 4370 4.830 2.430 2.260
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B.- Water: 40/45C. 10 m from the unit in free eld (Q = 2). Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software.
kW
120
213
kW
372
395
440
478
520
585
628
661
TCAETY-TCAEQY MODEL
4370
4400
4440
5470
6520
6580
6620
6660
TCAEY-THAEY 43506640
Cooling capacity: 335636 kW - Heating capacity: 357669 kW
Compact version B for replacement markets Up to 6 capacity steps Simplied installation with Tank&Pump accessory
Air-cooled water chillers and reversible heat pumps with axial fans. Range with hermetic Scroll compressors and R410A refrigerant.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection and crankcase heater. 4, 5 or 6 capacity steps with high eciency at partial loads. Electronic expansion valve: as standard on all models. Water side heat exchanger: stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water ow dierential pressure switch and Victaulic connections. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous regulation of fan rotation speed (S version only). Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - display of refrigerant circuit high/low pressure; - compressor and fan thermal overload switches; - clock card for displaying date/time and machine time band management.
Models
TCAEBY: unit designed for cooling only. TCAESY: silenced unit designed for cooling only. THAEBY: heat pump unit. THAESY: silenced heat pump unit.
Versions
B -Standard version (TCAEBY-THAEBY). S - Silenced version with lower fan speed and soundproofed compressor cover (TCAESY-THAESY).
Shell and tube evaporator. PUMP with single or double pump, including an automatic pump in standby. The pumps are available in the low or high pressure versions. TANK&PUMP with 1,100-litre built-in buer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. Desuperheater. 100% heat recovery. Thermostat with display for the heat recovery/desuperheater. -10C condensation control (as per standard in S version). -15C condensation control with fans with EC motor. Power factor correction capacitors (cos > 0.94). Forced limit of the power consumption. Soundproofed compressor box. Low and high pressure gauges for each refrigerant circuit. Bottom compartment protection grilles. Protection coil grilles. Evaporator antifreeze heater, buer tank and heat exchangers for heat recovery if present. Digital input for double set-point Control of min/max power supply voltage. 4-20 mA analogue input for shifting set-point. Copper/pre-painted aluminium or copper/copper coils. Serial interface for connection with external BMS. Spring antivibration mountings.
Remote keyboard with display. Rhoss sequencer for the integrated management of several water chillers.
COOLING ONLY
HEAT PUMP
OUTDOOR INSTALLATION
47
Nominal cooling capacity E.E.R. E.E.R. E.S.E.E.R. E.S.E.E.R.+ Absorbed power Absorbed power THAEBY-THAESY MODEL Nominal heating capacity Nominal heating capacity C.O.P. C.O.P. Nominal cooling capacity Nominal cooling capacity Absorbed power Absorbed power TCAEBY-TCAESY-THAEBY-THAESY MODEL Sound pressure level Sound pressure level Sound power level Sound power level Scroll/step compressor Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCAEBY Weight THAEBY
kW
364 2,82 2,66 4,19 4,65 134 137 4380 394 381 3,01 2,89 366 357 131 132 4380 63,0 58,0 95 90 4/4 2 400-3-50 4380 3.830 2.430 2.260 2.550 2.800
402 2,80 2,66 4,08 4,62 149 151 4410 435 420 3,02 2,88 405 391 144 146 4410 64,0 59,0 96 91 4/4 2 400-3-50 4410 3.830 2.430 2.260 2.590 2.840
440 2,84 2,68 4,18 4,67 161 164 5450 482 460 3,03 2,84 443 430 159 162 5450 64,0 59,0 96 91 5/5 2 400-3-50 5450 4.830 2.430 2.260 3.040 3.450
480 2,80 2,67 4,20 4,68 178 180 6500 512 495 3,01 2,86 483 470 170 173 6500 64,0 59,0 96 91 6/6 2 400-3-50 6500 4.830 2.430 2.260 3.190 3.600
541 2,81 2,68 4,15 4,63 200 202 6560 590 567 3,04 2,91 545 528 194 195 6560 64,0 59,0 96 91 6/6 2 400-3-50 6560 4.830 2.430 2.260 3.320 3.670
580 2,80 2,67 4,13 4,60 215 217 6600 634 609 3,05 2,87 586 568 208 212 6600 64,5 59,5 97 92 6/6 2 400-3-50 6600 5.830 2.430 2.260 3.640 4.130
613 2,81 2,69 4,10 4,57 228 6640 669 643 3,01 617 599 222 224 6640 65,5 98 93 6/6 2 400-3-50 6640 5.830 2.430 2.260 3.680 4.170 60,5 2,87
kW kW kW
342 335 123 124 4350 63,0 58,0 95 90 4/4 2 400-3-50 4350 3.830 2.430 2.260 2.500 2.730
TERMINAL UNITS
SYSTEM ACCESSORIES
In the following conditions: Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B.- Water: 40/45C. 10 m from the unit in free eld (Q = 2). Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. Weight refers to the accessorised unit with RPE - KRP when empty. ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software.
CONDENSING UNITS
kW
125
226
kW
354
378
417
457
498
561
603
636
TCAEBY-TCAESY MODEL
4350
4380
4410
5450
6500
6560
6600
6640
Z-Power Range
48
TCAVZ 12701390
Cooling capacity: 260389 kW
Eciency and compact range in R134a Working limits up to 50C Range with single compressor up to 390 kW
TCAVBZ 1350
Packaged air-cooled water chillers with axial fans. Range with semi-hermetic screw compressors and R134a refrigerant gas.
Construction features
Compressor: high energy eciency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and refrigerant gas delivery pipe shut-o valve. Electronic expansion valve: as standard on all models. Water side heat exchanger: dry expansion shell and tube exchanger, complete with closed cell polyurethane rubber foam insulation, water ow dierential pressure switch and Victaulic connections. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous regulation of fan rotation speed (S version only). Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - display of refrigerant circuit high/low pressure; - clock card for displaying date/time and machine time band management.
Models
TCAVBZ: unit designed for cooling only. TCAVSZ: silenced unit designed for cooling only. TCAVIZ: soundproofed unit designed for cooling only.
Versions
PUMP with single or double pump, including an automatic pump in standby. The pumps are available in the low or high pressure versions. Desuperheater. 100% heat recovery. Thermostat with display for the heat recovery/desuperheater. -10C condensation control (as per standard in S version). -15C condensation control with fans with EC motor. Power factor correction capacitors (cos > 0.94). Compressor and fan thermal overload switches. Forced limit of the power consumption. Inlet compressor shut-o valves. Low and high pressure gauges for each refrigerant circuit. Bottom compartment protection grilles. Protection coil grilles. Linear capacity control compressor. Evaporator antifreeze heater and heat recovery exchangers if present. Digital input for double set-point Compressor oil level sensor. Control of min/max power supply voltage. 4-20 mA analogue input for shifting set-point. Copper/pre-painted aluminium or copper/copper coils. Serial interface for connection with external BMS. Spring antivibration mountings.
B -Standard version (TCAVBZ). S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). I -Soundproofed version with soundproofed compressor cover (TCAVIZ).
Remote keyboard with display. Rhoss sequencer for the integrated management of several water chillers.
COOLING ONLY
OUTDOOR INSTALLATION
49
Nominal cooling capacity E.E.R. E.E.R. E.S.E.E.R. E.S.E.E.R. Absorbed power Absorbed power TCAVBZ-TCAVSZ MODEL Sound pressure level Sound pressure level Sound power level Sound power level Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCAVBZ Weight TCAVSZ
kW
300 2,81 2,72 3,59 3,41 110,0 110,5 1310 64 58 98 92 400-3-50 1310 3830 2430 2260 3350 3500 TCAVSZ silenced versions.
340 2,70 2,60 3,45 3,27 129,5 130,9 1350 64 58 98 92 400-3-50 1350 3830 2430 2260 3650 3800
374 2,70 2,55 3,44 3,26 146,7 1390 65 59 98 400-3-50 1390 3830 2430 2260 3700 3850 92
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Air: 35C - Water: 12/7C. 10 m from the unit in free eld (Q = 2). Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. Weight refers to the accessorised unit with RPE - KRP when empty. ESEER (European Seasonal EER) - Average European seasonal eciency.
kW
100,0
144,0
kW
270
309
350
389
TCAVBZ-TCAVIZ-TCAVSZ MODEL
1270
1310
1350
1390
Z-Power Range
50
Eciency range in CLASS A with EER >3.1 Working limits up to 55C (HT unit) Wide range of accessories
High energy eciency packaged air-cooled water chillers with axial fans. Range with semi-hermetic screw compressors and R134a refrigerant gas.
Construction features
Compressor: high energy eciency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and compressor discharge shut-o valve. Electronic expansion valve: as standard on all models. Water side heat exchanger (mod. 23302460): stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water ow dierential pressure switch and Victaulic connections. Water side heat exchanger (mod. 25102700): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water ow dierential pressure switch and Victaulic connections. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous regulation of fan rotation speed (S version only). Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - display of refrigerant circuit high/low pressure; - clock card for displaying date/time and machine time band management.
Models
TCAVBZ: unit designed for cooling only. TCAVSZ: silenced unit designed for cooling only. TCAVIZ: soundproofed unit designed for cooling only.
Versions
B - High energy eciency standard version (TCAVBZ). S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). I - High energy eciency soundproofed version with soundproofed compressor cover (TCAVIZ).
HT conguration for ambient temperature up to 55C. Shell and tube evaporator (mod. 23302460). PUMP with single or double pump, including an automatic pump in standby. The pumps are available in the low or high pressure versions. TANK&PUMP (mod. 23302460) with 1,100-litre built-in buer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. Desuperheater. 100% heat recovery. Thermostat with display for the heat recovery/desuperheater. -10C condensation control (as per standard in S version). -15C condensation control with fans with EC motor. Power factor correction capacitors (cos > 0.94). Compressor and fan thermal overload switches. Forced limit of the power consumption. Inlet compressor shut-o valves. Low and high pressure gauges for each refrigerant circuit. Bottom compartment protection grilles. Protection coil grilles. Linear compressor capacity control (25-100 %). Evaporator antifreeze heater, buer tank and heat exchangers for heat recovery if present. Digital input for double set-point Compressor oil level sensor. Control of min/max power supply voltage. 4-20 mA analogue input for shifting set-point. Copper/pre-painted aluminium or copper/copper coils. Serial interface for connection with external BMS. Spring antivibration mountings.
Remote keyboard with display. Rhoss sequencer for the integrated management of several water chillers. Web code: C5Z1
COOLING ONLY
OUTDOOR INSTALLATION
51
Nominal cooling capacity E.E.R. E.E.R. E.S.E.E.R. E.S.E.E.R. IPLV IPLV Absorbed power Absorbed power TCAVBZ-TCAVSZ H.E MODEL Sound pressure level Sound pressure level Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCAVBZ Weight TCAVIZ-TCAVSZ TCAVBZ-TCAVSZ-TCAVIZ H.E. MODEL Nominal cooling capacity Nominal cooling capacity E.E.R. E.E.R. E.S.E.E.R. E.S.E.E.R. IPLV IPLV Absorbed power Absorbed power TCAVBZ-TCAVSZ H.E MODEL Sound pressure level Sound pressure level Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCAVBZ Weight TCAVIZ-TCAVSZ
kW
344,1 3,11 3,06 4,06 3,98 4,22 4,14 113,7 112,5 2350 64 58 98 92 2/6 2 400-3-50 2350 4.830 2.430 2.260 3.870 4.170 2570 570,1 554,9 3,13 3,08 4,17 3,92 4,34 4,08 182,4 180,2 2570 66 60 99 93 2/6 2 400-3-50 2570 6.680 2.430 2.260 5.090 5.390
361,8 3,10 3,04 4,08 3,99 4,24 4,15 120,4 118,9 2370 64 58 98 92 2/6 2 400-3-50 2370 4.830 2.430 2.260 3.960 4.260 2610 611,1 593,1 3,14 3,07 4,17 3,97 4,34 4,12 194,7 193,5 2610 66 60 99 93 2/6 2 400-3-50 2610 6.680 2.430 2.260 5.110 5.410
379,4 3,10 2,96 4,06 3,99 4,22 4,15 126,1 128,1 2390 64 58 98 92 2/6 2 400-3-50 2390 4.830 2.430 2.260 3.970 4.270 2640 644,7 624,6 3,10 3,01 4,17 4,01 4,34 4,17 207,7 207,5 2640 66 60 99 93 2/6 2 400-3-50 2640 6.680 2.430 2.260 5.210 5.510
406,9 3,11 3,08 4,04 3,99 4,20 4,15 134,0 132,2 2420 65 59 98 92 2/6 2 400-3-50 2420 5.830 2.430 2.260 4.420 4.720
443,9 3,10 3,04 4,06 3,96 4,22 4,12 148,0 145,9 2460 65 59 98 92 2/6 2 400-3-50 2460 5.830 2.430 2.260 4.530 4.830 2680 674,5 657,0 3,14 3,08 4,18 4,04 4,34 4,20 214,9 213,5 2680 67 61 99 93 2/6 2 400-3-50 2680 7.680 2.430 2.260 6.140 6.440
495,4 3,11 3,01 4,08 3,93 4,09 164,3 164,4 2510 65 98 92 2/6 2 400-3-50 2510 2.430 2.260 4.740 5.040 2700 693,2 676,2 3,12 3,04 4,18 4,06 4,22 222,5 222,3 2700 67 61 99 93 2/8 2 400-3-50 2700 7.680 2.260 6.190 6.490 2.430 4,35 5.830 59
107,0 105,1 2330 64 58 98 92 2/6 2 400-3-50 2330 4.830 2.430 2.260 3.780 4.080 2550
kW kW
172,1 171,0 2550 66 60 99 93 2/6 2 400-3-50 2550 6.680 2.430 2.260 5.070 5.370
TERMINAL UNITS
In the following conditions: Air: 35C - Water: 12/7C. IPLV (Integrated Part Load Value) - ARI standard 550/590. 10 m from the unit in free eld (Q = 2). Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. Weight refers to the accessorised unit with RPE - KRP when empty. ESEER (European Seasonal EER) - Average European seasonal eciency.
SYSTEM ACCESSORIES
CONDENSING UNITS
4,24
kW
333,1
353,2
373,6
390,5
416,5
458,1
510,3
2330
2350
2370
2390
2420
2460
2510
Z-Power Range
52
TCAVZ 23312701
Cooling capacity: 320.6689.7 kW
TCAVSZ 2641
Packaged air-cooled water chillers with axial fans. Range with semi-hermetic screw compressors and R134a refrigerant gas.
Construction features
Compressor: high energy eciency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and compressor discharge shut-o valve. Electronic expansion valve: as standard on all models. Water side heat exchanger (mod. 23312511): stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water ow dierential pressure switch and Victaulic connections. Water side heat exchanger (mod. 25512701): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water ow dierential pressure switch and Victaulic connections. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous regulation of fan rotation speed (S version only). Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - display of refrigerant circuit high/low pressure; - clock card for displaying date/time and machine time band management.
Models
TCAVBZ: unit designed for cooling only. TCAVSZ: silenced unit designed for cooling only. TCAVIZ: soundproofed unit designed for cooling only.
Versions
Shell and tube evaporator (mod. 23312511). PUMP with single or double pump, including an automatic pump in standby. The pumps are available in the low or high pressure versions. TANK&PUMP (mod. 23312511) with 1,100-litre built-in buer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. Desuperheater. 100% heat recovery. Thermostat with display for the heat recovery/desuperheater. -10C condensation control (as per standard in S version). -15C condensation control with fans with EC motor. Power factor correction capacitors (cos > 0.94). Compressor and fan thermal overload switches. Forced limit of the power consumption. Inlet compressor shut-o valves. Low and high pressure gauges for each refrigerant circuit. Bottom compartment protection grilles. Protection coil grilles. Linear compressor capacity control (25-100 %). Evaporator antifreeze heater, buer tank and heat exchangers for heat recovery if present. Digital input for double set-point Compressor oil level sensor. Control of min/max power supply voltage. 4-20 mA analogue input for shifting set-point. Copper/pre-painted aluminium or copper/copper coils. Serial interface for connection with external BMS. Spring antivibration mountings.
B -Standard version (TCAVBZ). S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). I -Soundproofed version with soundproofed compressor cover (TCAVIZ).
Remote keyboard with display. Rhoss sequencer for the integrated management of several water chillers.
COOLING ONLY
OUTDOOR INSTALLATION
53
Nominal cooling capacity E.E.R. E.E.R. E.S.E.E.R. E.S.E.E.R. IPLV IPLV Absorbed power Absorbed power TCAVBZ-TCAVSZ MODEL Sound pressure level Sound pressure level Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCAVBZ Weight TCAVIZ-TCAVSZ
kW
338,9 2,95 2,83 3,97 3,79 4,11 3,93 118,9 119,6 2351 63 57 97 91 2/6 2 400-3-50 2351 3.830 2.430 2.260 3.490 3.790
359,1 2,92 2,80 3,97 3,82 4,12 3,96 126,9 128,2 2371 63 57 97 91 2/6 2 400-3-50 2371 3.830 2.430 2.260 3.500 3.800
373,3 2,90 2,71 3,99 3,84 4,13 3,99 134,0 137,6 2391 63 57 97 91 2/6 2 400-3-50 2391 3.830 2.430 2.260 3.580 3.880
401,1 2,93 2,85 3,99 3,86 4,15 4,01 141,2 140,8 2421 64 58 98 92 2/6 2 400-3-50 2421 4.830 2.430 2.260 3.920 4.220
439,0 2,92 2,80 3,92 3,74 4,07 3,88 155,6 156,6 2461 64 58 98 92 2/6 2 400-3-50 2461 4.830 2.430 2.260 4.100 4.400
486,9 2,91 2,76 3,84 3,61 3,74 173,8 176,2 2511 64 98 92 2/6 2 400-3-50 2511 2.430 2.260 4.280 4.580 4.830 58
112,6 112,7 2331 63 57 97 91 2/6 2 400-3-50 2331 3.830 2.430 2.260 3.420 3.720
Nominal cooling capacity Nominal cooling capacity E.E.R. E.E.R. E.S.E.E.R. E.S.E.E.R. IPLV IPLV Absorbed power Absorbed power TCAVBZ-TCAVSZ MODEL Sound pressure level Sound pressure level Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCAVBZ Weight TCAVIZ-TCAVSZ
kW kW
565,0 546,9 2,94 2,84 3,99 3,84 4,15 3,99 192,2 192,7 2571 65 59 98 92 2/6 2 400-3-50 2571 5.830 2.430 2.260 4.780 5.080
606,2 585,0 2,90 2,77 3,97 3,83 4,13 3,98 209,0 211,0 2611 65 59 98 92 2/6 2 400-3-50 2611 5.830 2.430 2.260 4.800 5.100
641,5 617,3 2,90 2,75 3,96 3,83 4,11 3,97 221,2 224,6 2641 65 59 98 92 2/6 2 400-3-50 2641 5.830 2.430 2.260 4.820 5.120
671,5 651,9 2,92 2,82 3,96 3,81 4,11 3,96 230,0 231,3 2681 66 60 99 93 2/6 2 400-3-50 2681 6.680 2.430 2.260 5.160 5.460
691,1 671,6 2,90 2,78 3,96 3,80 3,95 238,3 241,2 2701 66 60 99 93 2/8 2 400-3-50 2701 6.680 2.260 5.210 5.510 2.430 4,12
182,2 181,9 2551 65 59 98 92 2/6 2 400-3-50 2551 5.830 2.430 2.260 4.760 5.060
TERMINAL UNITS
In the following conditions: Air: 35C - Water: 12/7C. IPLV (Integrated Part Load Value) - ARI standard 550/590. 10 m from the unit in free eld (Q = 2). Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. Weight refers to the accessorised unit with RPE - KRP when empty. ESEER (European Seasonal EER) - Average European seasonal eciency.
SYSTEM ACCESSORIES
CONDENSING UNITS
TCAVBZ-TCAVSZ-TCAVIZ MODEL
2551
2571
2611
2641
2681
2701
3,98
kW
331,1
350,7
370,6
388,5
413,6
454,4
505,7
TCAVBZ-TCAVSZ-TCAVIZ MODEL
2331
2351
2371
2391
2421
2461
2511
Z-Power Range
54
Eciency range in CLASS A with EER >3.2 and ESEER up to 4.57 Working limits up to 55C (HT unit) Standard electronic expansion valve
High energy eciency packaged air-cooled water chillers with axial fans. Range with semi-hermetic screw compressors and R134a refrigerant gas.
Construction features
Compressor: high energy eciency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and compressor discharge shut-o valve. Electronic expansion valve: as standard on all models. Water side heat exchanger: dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water ow dierential pressure switch and Victaulic connections. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous regulation of fan rotation speed (S version only). Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - display of refrigerant circuit high/low pressure; - clock card for displaying date/time and machine time band management.
TCAVBZ 2890 H.E.
Models
TCAVBZ: unit designed for cooling only. TCAVSZ: silenced unit designed for cooling only. TCAVIZ: soundproofed unit designed for cooling only.
HT conguration for ambient temperature up to 55C. Desuperheater. 100% heat recovery. Thermostat with display for the heat recovery/desuperheater. -10C condensation control (as per standard in S version). -15C condensation control with fans with EC motor. Power factor correction capacitors (cos > 0.94). Compressor and fan thermal overload switches. Forced limit of the power consumption. Inlet compressor shut-o valves. Low and high pressure gauges for each refrigerant circuit. Bottom compartment protection grilles. Protection coil grilles. Linear compressor capacity control (25-100%). Evaporator antifreeze heater and heat recovery exchangers if present. Digital input for double set-point Compressor oil level sensor. Control of min/max power supply voltage. 4-20 mA analogue input for shifting set-point. Copper/pre-painted aluminium or copper/copper coils. Serial interface for connection with external BMS. Spring antivibration mountings.
Versions
B - High energy eciency standard version (TCAVBZ). S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). I - High energy eciency soundproofed version with soundproofed compressor cover (TCAVIZ).
Remote keyboard with display. Rhoss sequencer for the integrated management of several water chillers.
COOLING ONLY
OUTDOOR INSTALLATION
55
Nominal cooling capacity E.E.R. E.E.R. E.S.E.E.R. E.S.E.E.R. IPLV IPLV Absorbed power Absorbed power TCAVBZ-TCAVSZ H.E MODEL Sound pressure level Sound pressure level Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCAVBZ Weight TCAVIZ-TCAVSZ
kW
811,2 3,31 3,17 4,39 4,22 4,57 4,39 251,0 256,1 2830 67 61 100 94 2/8 2 400-3-50 2830 7.680 2.430 2.260 6.360 6.700
865,5 3,26 3,09 4,34 4,12 4,51 4,28 272,0 279,8 2890 67 61 100 94 2/8 2 400-3-50 2890 7.680 2.430 2.260 6.760 7.100
924,0 3,37 3,16 4,48 4,20 4,66 4,37 284,0 292,6 2960 69 63 101 95 2/8 2 400-3-50 2960 8.980 2.430 2.260 7.900 8.250
973,5 3,35 3,13 4,47 4,16 4,65 4,33 301,0 311,5 21010 69 63 101 95 2/8 2 400-3-50 21010 8.980 2.430 2.260 7.920 8.260
1.004,2 3,35 3,16 4,45 4,21 4,37 310,0 317,9 21040 69 101 95 2/8 2 400-3-50 21040 2.430 2.260 7.990 8.340 9.980 63
228,0 230,6 2770 67 61 100 94 2/8 2 400-3-50 2770 7.680 2.430 2.260 5.950 6.290
Nominal cooling capacity Nominal cooling capacity E.E.R. E.E.R. E.S.E.E.R. E.S.E.E.R. IPLV IPLV Absorbed power Absorbed power TCAVBZ-TCAVSZ H.E MODEL Sound pressure level Sound pressure level Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCAVBZ Weight TCAVIZ-TCAVSZ
kW kW
1.125,9 1.099,9 3,23 3,08 4,29 4,10 4,46 4,26 349,0 357,0 21130 70 64 102 96 2/8 2 400-3-50 21130 10.980 2.430 2.260 8.720 9.070
1.152,3 1.116,2 3,43 3,21 4,57 4,27 4,75 4,44 336,0 348,0 21150 70 64 102 96 2/8 2 400-3-50 21150 10.980 2.430 2.260 9.160 9.510
1.217,9 1.178,1 3,40 3,14 4,53 4,16 4,71 4,33 358,0 375,8 21220 70 64 102 96 2/8 2 400-3-50 21220 10.980 2.430 2.260 9.200 9.560
1.283,4 1.240,4 3,39 3,08 4,51 4,10 4,26 379,0 402,2 21290 70 64 102 96 2/8 2 400-3-50 21290 10.980 2.260 9.240 9.590 2.430 4,69
321,0 326,0 21080 70 64 102 96 2/8 2 400-3-50 21080 10.980 2.430 2.260 7.960 8.300
TERMINAL UNITS
In the following conditions: Air: 35C - Water: 12/7C. IPLV (Integrated Part Load Value) - ARI standard 550/590. 10 m from the unit in free eld (Q = 2). Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. Weight refers to the accessorised unit with RPE - KRP when empty. ESEER (European Seasonal EER) - Average European seasonal eciency.
SYSTEM ACCESSORIES
CONDENSING UNITS
21080
21130
21150
21220
21290
4,63
kW
764,5
831,5
887,8
956,8
1.009,7
1.037,3
2770
2830
2890
2960
21010
21040
Z-Power Range
56
TCAVZ 271021600
Cooling capacity: 6901.602 kW
Packaged air-cooled water chillers with axial fans. Range with semi-hermetic screw compressors and R134a refrigerant gas.
Construction features
Compressor: high energy eciency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and compressor discharge shut-o valve. Electronic expansion valve: as standard on all models. Water side heat exchanger: dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water ow dierential pressure switch and Victaulic connections. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous regulation of fan rotation speed (S version only). Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - display of refrigerant circuit high/low pressure; - clock card for displaying date/time and machine time band management.
Models
TCAVBZ: unit designed for cooling only. TCAVSZ: silenced unit designed for cooling only. TCAVIZ: soundproofed unit designed for cooling only.
Desuperheater. 100% heat recovery. Thermostat with display for the heat recovery/desuperheater. -10C condensation control (as per standard in S version). -15C condensation control with fans with EC motor. Power factor correction capacitors (cos > 0.94). Compressor and fan thermal overload switches. Forced limit of the power consumption. Inlet compressor shut-o valves. Low and high pressure gauges for each refrigerant circuit. Bottom compartment protection grilles. Protection coil grilles. Linear compressor capacity control (25-100 %). Evaporator antifreeze heater and heat recovery exchangers if present. Digital input for double set-point Compressor oil level sensor. Control of min/max power supply voltage. 4-20 mA analogue input for shifting set-point. Copper/pre-painted aluminium or copper/copper coils. Serial interface for connection with external BMS. Spring antivibration mountings.
Versions
B -Standard version (TCAVBZ). S - Silenced version with lower fan speed and soundproofed compressor cover (TCAVSZ). I -Soundproofed version with soundproofed compressor cover (TCAVIZ).
Remote keyboard with display. Rhoss sequencer for the integrated management of several water chillers.
COOLING ONLY
OUTDOOR INSTALLATION
57
Nominal cooling capacity E.E.R. E.E.R. E.S.E.E.R. E.S.E.E.R. IPLV IPLV Absorbed power Absorbed power TCAVBZ-TCAVSZ MODEL Sound pressure level Sound pressure level Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCAVBZ Weight TCAVIZ-TCAVSZ TCAVBZ-TCAVSZ-TCAVIZ MODEL Nominal cooling capacity Nominal cooling capacity E.E.R. E.E.R. E.S.E.E.R. E.S.E.E.R. IPLV IPLV Absorbed power Absorbed power TCAVBZ-TCAVSZ MODEL Sound pressure level Sound pressure level Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCAVBZ Weight TCAVIZ-TCAVSZ
kW
732,0 2,98 2,85 3,72 3,56 4,12 3,94 252,0 257,0 2750 66 60 100 94 2/8 2 400-3-50 2750 6.680 2.430 2.260 5.310 5.610 21110 1.107,3 1.071,8 2,99 2,78 3,74 3,47 4,14 3,85 370,5 385,0 21110 69 63 102 96 2/8 2 400-3-50 21110 8.980 2.430 2.260 8.530 8.880 21180 1.179,7 1.142,7 3,07 2,85 3,84 3,54 4,25 3,93 384,3 401,2 21180 69 63 102 96 2/8 2 400-3-50 21180 8.980 2.430 2.260 8.740 9.090
785,9 2,96 2,82 3,69 3,53 4,09 3,91 273,2 278,4 2810 67 61 100 94 2/8 2 400-3-50 2810 7.680 2.430 2.260 6.400 6.750 21250 1.251,5 1.212,2 3,15 2,90 3,93 3,63 4,35 4,02 397,7 417,3 21250 69 63 102 96 2/8 2 400-3-50 21250 8.980 2.430 2.260 8.930 9.280
838,0 2,91 2,77 3,53 3,35 4,03 3,83 296,2 303,0 2870 67 61 103 97 2/8 2 400-3-50 2870 7.680 2.430 2.260 6.620 6.970 21330 1.333,0 1.288,0 3,15 2,91 3,96 3,65 4,36 4,02 423,0 442,6 21330 69 63 102 96 2/8 2 400-3-50 21330 9.980 2.430 2.260 9.330 9.680
908,6 3,01 2,86 3,76 3,57 4,17 3,95 310,6 318,2 2940 68 62 101 95 2/8 2 400-3-50 2940 7.680 2.430 2.260 6.790 7.140 21400 1.400,0 1.353,0 3,12 2,92 4,01 3,82 4,30 4,01 448,8 464,0 21400 70 64 103 97 2/8 2 400-3-50 21400 10.980 2.430 2.260 9.690 10.040
954,0 2,98 2,81 3,74 3,50 4,14 3,89 329,9 339,6 2990 68 62 101 95 2/8 2 400-3-50 2990 7.680 2.430 2.260 6.820 7.170 21500 1.500,0 1.446,7 3,12 2,88 4,06 3,81 4,33 4,00 480,8 501,9 21500 71 65 104 98 2/8 2 400-3-50 21500 12.980 2.430 2.260 9.840 10.190
984,6 3,05 2,87 3,80 3,59 3,97 333,4 343,3 21020 68 101 95 2/8 2 400-3-50 21020 2.430 2.260 6.940 7.290 21600 1.602,0 1.548,0 3,11 2,80 4,08 3,72 3,87 515,0 553,0 21600 71 65 104 98 2/8 2 400-3-50 21600 12.980 2.260 10.080 10.430 2.430 4,29 7.680 62
240,0 245,0 2710 66 60 100 94 2/8 2 400-3-50 2710 6.680 2.430 2.260 5.310 5.610 21060
kW kW
335,7 346,0 21060 69 63 102 96 2/8 2 400-3-50 21060 7.680 2.430 2.260 6.970 7.390
TERMINAL UNITS
In the following conditions: Air: 35C - Water: 12/7C. IPLV (Integrated Part Load Value) - ARI standard 550/590. 10 m from the unit in free eld (Q = 2). Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. Weight refers to the accessorised unit with RPE - KRP when empty. ESEER (European Seasonal EER) - Average European seasonal eciency.
SYSTEM ACCESSORIES
CONDENSING UNITS
4,21
kW
710,0
751,1
809,3
863,4
935,5
984,6
1.015,5
TCAVBZ-TCAVSZ-TCAVIZ MODEL
2710
2750
2810
2870
2940
2990
21020
Z-Power Range
58
Super-silenced version with low acoustic impact Range from 300 to 1210 kW Wide range of accessories
High energy eciency packaged air-cooled water chillers with axial fans. Range with semi-hermetic screw compressors and R134a refrigerant gas.
Construction features
Compressor: high energy eciency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater and compressor discharge shut-o valve. Electronic expansion valve: as standard on all models. Water side heat exchanger (mod. 23302460): stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water ow dierential pressure switch and Victaulic connections. Water side heat exchanger (mod. 251021290): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water ow dierential pressure switch and Victaulic connections. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: electric axial fans with EC motor with continuous adjustment of the rotation speed, equipped with internal thermal protection and complete with protection grilles. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - display of refrigerant circuit high/low pressure; - clock card for displaying date/time and machine time band management.
Models
Shell and tube evaporator (mod. 23302460). PUMP (mod. 23302700) with single or double pump, including an automatic pump in standby. The pumps are available in the low or high pressure versions. TANK&PUMP (mod. 23302460) with 1,100-litre built-in buer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. Desuperheater. 100% heat recovery. Thermostat with display for the heat recovery/desuperheater. Power factor correction capacitors (cos > 0.94). Compressor and fan thermal overload switches. Forced limit of the power consumption. Inlet compressor shut-o valves. Low and high pressure gauges for each refrigerant circuit. Bottom compartment protection grilles. Protection coil grilles. Linear compressor capacity control (25-100 %). Evaporator antifreeze heater, buer tank and heat exchangers for heat recovery if present. Digital input for double set-point Compressor oil level sensor. Control of min/max power supply voltage. 4-20 mA analogue input for shifting set-point. Copper/pre-painted aluminium or copper/copper coils. Serial interface for connection with external BMS. Spring antivibration mountings.
Versions
Q - Supersilenced version with super-low speed fans with EC motor, high acoustic impedance and soundproofed compressor cover and a larger condensing section (TCAVQZ).
Remote keyboard with display. Rhoss sequencer for the integrated management of several water chillers.
C5Z1 C4Z2
COOLING ONLY
OUTDOOR INSTALLATION
59
E.E.R. E.S.E.E.R. Absorbed power Sound pressure level Sound power level Scroll/step compressor Circuits Electrical supply DIMENSIONS L - Width H - Height P - Depth TCAVQZ MODEL Nominal cooling capacity E.E.R. E.S.E.E.R. Absorbed power Sound pressure level Sound power level Scroll/step compressor Circuits Electrical supply DIMENSIONS L - Width H - Height P - Depth mm mm mm kW dB(A) dB(A) no. no. V-ph-Hz kW mm mm mm kW dB(A) dB(A) no. no. V-ph-Hz
2,95 4,09 107 54 88 2/6 2 400-3-50 2330 4.830 2.430 2.260 2570 539 2,95 4,13 183 56 89 2/6 2 400-3-50 2570 6.680 2.430 2.260
2,95 4,10 114 54 88 2/6 2 400-3-50 2350 4.830 2.430 2.260 2610 576 2,94 4,15 196 56 89 2/6 2 400-3-50 2610 6.680 2.430 2.260
2,90 4,12 121 54 88 2/6 2 400-3-50 2370 4.830 2.430 2.260 2640 609 2,90 4,17 210 56 89 2/6 2 400-3-50 2640 6.680 2.430 2.260
2,85 4,11 130 54 88 2/6 2 400-3-50 2390 4.830 2.430 2.260 2680 638 2,95 4,19 216 57 89 2/6 2 400-3-50 2680 7.680 2.430 2.260
2,95 4,10 134 55 88 2/6 2 400-3-50 2420 5.830 2.430 2.260 2700 656 2,92 4,20 225 57 89 2/8 2 400-3-50 2700 7.680 2.430 2.260
2,91 4,09 148 55 88 2/6 2 400-3-50 2460 5.830 2.430 2.260 2770 724 3,11 4,47 233 57 90 2/8 2 400-3-50 2770 7.680 2.430 2.260
2,90 4,09 167 55 88 2/6 2 400-3-50 2510 5.830 2.430 2.260 2830 787 3,04 4,39 259 57 90 2/8 2 400-3-50 2830 7.680 2.430 2.260
2,98 4,11 173 56 89 2 400-3-50 2550 6.680 2.430 2.260 2890 844 2,98 4,31 283 57 90 2/8 2 400-3-50 2890 2.430 2.260 7.680
TCAVQZ MODEL Nominal cooling capacity E.E.R. E.S.E.E.R. Absorbed power Sound pressure level Sound power level Scroll/step compressor Circuits Electrical supply DIMENSIONS L - Width H - Height P - Depth In the following conditions: Air: 35C - Water: 12/7C. 10 m from the unit in free eld (Q = 2). mm mm mm kW dB(A) dB(A) no. no. V-ph-Hz kW
2960 897 3,03 4,43 296 59 91 2/8 2 400-3-50 2960 8.980 2.430 2.260
21010 950 3,02 4,40 315 59 91 2/8 2 400-3-50 21010 8.980 2.430 2.260
21040 975 3,03 4,42 322 59 91 2/8 2 400-3-50 21040 9.980 2.430 2.260
21080 1.020 3,09 4,47 330 60 92 2/8 2 400-3-50 21080 10.980 2.430 2.260
21130 1.073 2,97 4,28 361 60 92 2/8 2 400-3-50 21130 10.980 2.430 2.260
21150 1.083 3,08 4,51 352 60 92 2/8 2 400-3-50 21150 10.980 2.430 2.260
21220 1.143 3,01 4,43 380 60 92 2/8 2 400-3-50 21220 10.980 2.430 2.260
21290 1.210 2,97 4,39 407 60 92 2/8 2 400-3-50 21290 10.980 2.430 2.260
TERMINAL UNITS
Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. ESEER (European Seasonal EER) - Average European seasonal eciency.
SYSTEM ACCESSORIES
CONDENSING UNITS
2/6
kW
316
336
351
370
395
431
484
516
TCAVQZ MODEL
2330
2350
2370
2390
2420
2460
2510
2550
TCAIIZ 252021030
Cooling capacity: 5161,032 kW
IN
IN
ER T ER
Screw compressors with variable Vi, suitable for all applications Continuous power regulation: 20-100% High energy eciency EC fans (brushless) ESEER up to 4.94
Packaged air-cooled water chillers with axial fans. Range with semi-hermetic screw compressors with variable Vi, inverter regulation and R134a refrigerant gas.
Construction features
Compressor: high energy eciency semi-hermetic screw compressor with variable Vi intrinsic compression ratio, star-delta limited start, inverter rotation regulation, complete with integral protection, crankcase heater and refrigerant gas intake and outlet pipe shut-o valve. Electronic expansion valve: as standard on all models. Water side heat exchanger: dry expansion shell and tube exchanger, complete with closed cell polyurethane rubber foam insulation, water ow dierential pressure switch and Victaulic connections. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: electric axial fans with EC motor with continuous adjustment of the rotation speed, equipped with internal thermal protection and complete with protection grilles. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - display of refrigerant circuit high/low pressure; - compressor and fan thermal overload switches; - clock card for displaying date/time and machine time band management.
TCAIIZ 2600
Versions
I - Soundproofed version with high acoustic impedance and soundproofed compressor cover (TCAIIZ).
Models
Low and high pressure gauges for each refrigerant circuit. Bottom compartment protection grilles. Protection coil grilles. Evaporator antifreeze electric heater. Digital input for double set-point Control of min/max power supply voltage. 4-20 mA analogue input for shifting set-point. Copper/pre-painted aluminium or copper/copper coils. Serial interface for connection with external BMS. Spring antivibration mountings.
COOLING ONLY
OUTDOOR INSTALLATION
61
PRELIMINARY
E.E.R. E.S.E.E.R. Absorbed power Sound pressure level Sound power level Screw/step compressor Circuits Electrical supply DIMENSIONS L - Width H - Height P - Depth mm mm mm kW dB(A) dB(A) no. no. V-ph-Hz
In the following conditions: Air: 35C - Water: 12/7C. 10 m from the unit in free eld (Q = 2). Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. ESEER (European Seasonal EER) - Average European seasonal eciency.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
2/INFINITE
kW
516
600
673
780
903
1.032
TCAIIZ MODEL
2520
2600
2670
2780
2900
21030
Z-Power Range
62
THAVZ 24002680
Cooling capacity: 384680 kW - Heating capacity: 409700 kW
Heat pump eciency in R134a Extended working limits Production of hot water up to 55C
Packaged air-cooled reversible heat pumps with axial fans. Range with semi-hermetic screw compressors and R134a refrigerant gas.
Construction features
Compressor: high energy eciency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater, refrigerant gas delivery piping shut-o valve and compressor oil level sensor. Electronic expansion valve: as standard on all models. Water side heat exchanger: dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water ow dierential pressure switch and Victaulic connections. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous regulation of fan rotation speed (S version only). Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - display of refrigerant circuit high/low pressure; - clock card for displaying date/time and machine time band management.
THAVSZ 2530
Models
THAVBZ: heat pump unit. THAVSZ: silenced heat pump unit. THAVIZ: soundproofed heat pump unit.
Desuperheater. 100% heat recovery. Thermostat with display for the heat recovery/desuperheater. -10C condensation control (as per standard in S version). -15C condensation control with fans with EC motor. Power factor correction capacitors (cos > 0.94). Compressor and fan thermal overload switches. Forced limit of the power consumption. Inlet compressor shut-o valves. Low and high pressure gauges for each refrigerant circuit. Bottom compartment protection grilles. Protection coil grilles. Evaporator antifreeze heater and heat recovery exchangers if present. Digital input for double set-point Control of min/max power supply voltage. 4-20 mA analogue input for shifting set-point. Copper/pre-painted aluminium or copper/copper coils. Serial interface for connection with external BMS. Spring antivibration mountings.
Versions
Remote keyboard with display. Rhoss sequencer for the integrated management of several water chillers.
B - Standard version (THAVBZ). S - Silenced version with lower fan speed and soundproofed compressor cover (THAVSZ). I -Soundproofed version with soundproofed compressor cover (THAVIZ).
COOLING ONLY
OUTDOOR INSTALLATION
63
Nominal heating capacity C.O.P. C.O.P. Nominal cooling capacity Nominal cooling capacity E.E.R. E.E.R. Absorbed power Absorbed power Absorbed power Absorbed power THAVBZ-THAVSZ MODEL Sound pressure level Sound pressure level Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight THAVBZ Weight THAVSZ-THAVIZ
kW
467 3,06 2,95 464 446 2,81 2,71 158,9 158,1 165,4 164,6 2460 65 59 98 92 2/6 2 400-3-50 2460 6.130 2.430 2.260 5.350 5.700 THAVSZ silenced version.
540 3,17 3,06 532 511 2,88 2,78 177,6 176,7 184,7 183,8 2530 65 59 98 92 2/6 2 400-3-50 2530 6.130 2.430 2.260 5.740 6.090
595 3,15 3,04 600 576 2,97 2,86 196,8 195,8 202,4 201,4 2600 66 60 99 93 2/6 2 400-3-50 2600 6.980 2.430 2.260 6.320 6.670
672 3,17 3,06 680 653 2,90 220,7 219,6 226,4 225,3 67 61 99 93 2/6 2 2680 7.980 2.430 2.260 7.210 7.560 400-3-50 2680
kW kW
141,9 141,2 148,2 147,5 2400 64 58 98 92 2/6 2 400-3-50 2400 5.130 2.430 2.260 4.315 4.665
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B.- Water: 40/45C. 10 m from the unit in free eld (Q = 2). Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. Weight refers to the accessorised unit with RPE - KRP when empty. ESEER (European Seasonal EER) - Average European seasonal eciency.
3,00
kW
426
486
563
620
700
THAVBZ-THAVSZ-THAVIZ MODEL
2400
2460
2530
2600
2680
T-Power Range
64
Range in CLASS A with EER up to 3.53 Ecient Oil-Free compressor, silent and with low start current H.E. version with ooded evaporator
TCATBZ 2600
Packaged air-cooled water chillers with axial fans. Range with oil-free centrifugal compressors and R134a refrigerant gas.
Construction features
Compressor: high energy eciency , oil free, centrifugal compressor with limited start, equipped with magnetic levitation bearings and complete with integral protection and suction and supply shut-o valves Electronic expansion valve: as standard on all models. Water side heat exchanger: dry expansion shell and tube exchanger(TCATBZ) or ooded type (TCATTZ), complete with closed cell polyurethane rubber foam insulation, water ow dierential pressure switch and Victaulic connections. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protective grilles and proportional electronic device for continuous fan rotation speed regulation. Control: electronic microprocessor control with serial interface for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - condensation control down to an outdoor air temperature of 10C; - compressor and fan thermal overload switches; - high and low pressure on display for every cooling circuit.
Versions
B - Standard version with dry expansion evaporator (TCATBZ). T - High energy eciency version with ooded evaporator (TCATTZ).
Models
TCATBZ: unit designed for cooling only. TCATTZ: unit designed for cooling only.
Bottom compartment protection grilles. Heat exchanger antifreeze heater. Copper/pre-painted aluminium or copper/copper coils.
TPW1 TPW2
COOLING ONLY
OUTDOOR INSTALLATION
65
E.E.R. E.S.E.E.R. Absorbed power Sound pressure level Sound power level Compressor/steps Circuits Electrical supply DIMENSIONS L - Width H - Height P - Depth TCATTZ MODEL Nominal cooling capacity E.E.R. E.S.E.E.R. Absorbed power Sound pressure level Sound power level Compressor/steps Circuits Electrical supply DIMENSIONS L - Width H - Height P - Depth TCATTZ MODEL Nominal cooling capacity E.E.R. E.S.E.E.R. Absorbed power Sound pressure level Sound power level Compressor/steps Circuits Electrical supply DIMENSIONS L - Width H - Height P - Depth mm mm mm kW dB(A) dB(A) no. no. V-ph-Hz kW mm mm mm kW dB(A) dB(A) no. no. V-ph-Hz kW mm mm mm kW dB(A) dB(A) no. no. V-ph-Hz
3,10 4,88 80,6 56 88 1/infinite 1 400-3-50 1250 3.830 2.430 2.260 1260 260 3,52 5,09 73,9 56 88 1/infinite 1 400-3-50 1260 3.830 2.430 2.260
3,10 4,91 96,8 56 88 1/infinite 1 400-3-50 1300 3.830 2.430 2.260 1320 320 3,46 5,13 92,5 56 88 1/infinite 1 400-3-50 1320 3.830 2.430 2.260 2720 720 3,43 5,50 209,9 60 93 2/infinite 1 400-3-50 2720 7.680 2.430 2.260
3,11 4,89 128,6 59 91 2/infinite 1 400-3-50 1400 4.830 2.430 2.260 1350 350 3,37 5,18 103,9 59 91 1/infinite 1 400-3-50 1350 4.830 2.430 2.260 2780 780 3,38 5,51 230,8 61 94
3,11 5,03 144,7 59 91 2/infinite 2 400-3-50 2450 5.830 2.430 2.260 1400 400 3,36 5,15 119,0 59 91 1/infinite 1 400-3-50 1400 4.830 2.430 2.260 3960 960 3,42 5,52 280,7 62 95 3/infinite 1 400-3-50 3960 10.980 2.430 2.260
3,10 5,17 161,3 59 91 2/infinite 2 400-3-50 2500 5.830 2.430 2.260 2450 450 3,51 5,28 128,2 59 91 2/infinite 1 400-3-50 2450 5.830 2.430 2.260
3,11 5,18 225,1 60 93 2/infinite 2 400-3-50 2700 7.680 2.430 2.260 2520 520 3,53 5,37 147,3 59 91 2/infinite 1 400-3-50 2520 5.830 2.430 2.260
3,12 5,24 256,4 61 94 2 400-3-50 2800 8.980 2.430 2.260 2640 640 3,46 5,34 185,0 93 2/infinite 1 400-3-50 2640 6.680 2.430 2.260 41280 1.280 3,46 5,51 369,9 63 96 4/infinite 2 400-3-50 41280 12.980 2.430 2.260 60
41040 1.040 3,52 5,53 295,5 62 95 4/infinite 2 400-3-50 41040 10.980 2.430 2.260
TERMINAL UNITS
In the following conditions: Air: 35C - Water: 12/7C. 10 m from the unit in free eld (Q = 2). Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. ESEER (European Seasonal EER) - Average European seasonal eciency.
SYSTEM ACCESSORIES
CONDENSING UNITS
2/infinite
kW
250
300
350
400
450
500
600
700
800
TCATBZ MODEL
1250
1300
1350
1400
2450
2500
2600
2700
2800
TCCEY-THCEY 105111
Cooling capacity: 4.810.4 kW - Heating capacity: 511 kW
Packaged air-cooled water chillers and reversible heat pumps with centrifugal fans. Range with hermetic Scroll compressors and R410A refrigerant gas.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch. Air side heat exchanger: featuring nned coil with copper pipes and aluminium ns, complete with protection grille. Fan: centrifugal electric fan with directly coupled motor, tted with internal thermal protection and protection grilles. Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. Structure: in galvanised and painted sheet steel, complete with condensation drain pan for THCEY.
Soft - start device (for models with power supply 230V). -10C condensation control. Low pressure switch. Compressor crankcase heater. Digital input for double set-point 4-20 mA analogue input for shifting set-point.
Models
TCCEY: unit designed for cooling only. THCEY: heat pump unit.
PUMP unit
Pump assembly complete with: circulator, expansion tank with membrane, safety valve.
Antivibration rubber mountings. -10C condensation control. Water lter. Low pressure switch. Antifreeze electric heater on the buer tank. Inlet antivibration connection. Outlet antivibration connection. External air temperature probe for set-point compensation. Additional electric heater for heat pump, managed by regulation. Remote keyboard with display. Clock card Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management.
Pump assembly complete with: water buer tank, circulation pump, expansion tank with membrane, manual air bleed valve, automatic air bleed valve, safety valve.
COOLING ONLY
HEAT PUMP
INDOOR INSTALLATION
67
Nominal cooling capacity E.E.R. E.S.E.E.R. E.S.E.E.R.+ Absorbed power (*) Nominal heating capacity C.O.P. Absorbed power (*) Sound pressure level Scroll/step compressor Circuits Fan nominal air flow Fan available static pressure Water buffer tank content Circulation pump available head pressure Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height PUMP H - Height TANK & PUMP P - Depth Weight TCCEY Weight THCEY
kW
5,9 2,27 2,51 2,76 2,59 6,3 2,49 2,53 48 1/1 1 2.400 70 19 60 230-1-50 / 400-3+N-50 107 990 940 940 630 145 155
8,2 2,27 2,61 2,89 3,61 8,3 2,29 3,62 50 1/1 1 2.650 80 30 87 230-1-50 / 400-3+N-50 109 990 1.125 1.330 630 164 174
10,0 / 10,4 2,27 / 2,36 2,55 / 2,58 2,78 / 2,84 4,40 10,6 / 11,0 4,20 51 1/1 1 2.600 30 79 230-1-50 / 400-3+N-50 111 990 1.330 630 178 188 1.125 70
V-ph-Hz
mm mm mm mm kg kg
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B. - Water: 40/45C. 5 m from the unit in free eld (Q = 2). The weight refers to the unit in its most complete form.
ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software.
2,52 / 2,62
TCCEY-THCEY MODEL
105
107
109
111
Compact Range
68
TCCE-THCE 114126
Cooling capacity: 13.522 kW - Heating capacity: 13.624 kW
Packaged air-cooled water chillers and reversible heat pumps with centrifugal fans. Range with hermetic Scroll compressors and R407C refrigerant gas.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection. Water side heat exchanger: adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch. Air side heat exchanger: featuring nned coil with copper pipes and aluminium ns, complete with protection grille. Fan: centrifugal electric fans with directly coupled motor, tted with internal thermal protection and protection grilles. The condensation air supply is vertical. Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function logic. Structure: peraluman, complete with condensation drain pan for THCE.
With standard pump. With high-pressure pump. Pump assembly complete with: water buer tank, standard or high-pressure circulation pump for models 114-117 only, expansion tank with membrane, manual air bleed valve, safety valve and water drain tap.
Horizontal condensation air outlet. Antifreeze electric heater on the buer tank. Digital input for double set-point 4-20 mA analogue input for shifting set-point.
Models
TCCE: unit designed for cooling only. THCE: heat pump unit.
STANDARD unit
Antivibration rubber mountings. -10C condensation control. Inlet antivibration connection. Outlet antivibration connection. Additional electric heater for heat pump, not managed by regulation. Remote keyboard with display. Clock card Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management.
COOLING ONLY
HEAT PUMP
INDOOR INSTALLATION
69
Nominal cooling capacity E.E.R. Absorbed power (*) Nominal heating capacity C.O.P. Absorbed power (*) Sound pressure level Scroll/step compressor Circuits Fan nominal air flow Fan available static pressure Water buffer tank content Available head pressure of standard pump Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height STANDARD H - Height TANK & PUMP P - Depth Weight TCCE Weight THCE
13,5 2,55 5,31 13,6 2,58 5,27 54 1/1 1 4.720 90 55 50 179 400-3+N-50 114 1.320 1.305 1.600 558 340 350
15,5 2,53 6,13 16,4 2,72 6,02 55 1/1 1 4.110 80 55 48 165 400-3+N-50 117 1.320 1.305 1.600 558 360 370
18,2 2,40 7,57 20,1 2,80 7,18 56 1/1 1 5.040 90 80 170 400-3+N-50 121 1.710 1.305 1.600 643 420 440
22,0 2,34 9,40 24,0 2,71 8,86 1/1 1 4.485 80 80 400-3+N-50 126 1.710 1.305 1.600 460 470 643 159
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B. - 70% R.H.- Water: 40/45C. At 5 m from the unit in free eld (Q = 2), with ducted fans. The weight refers to the unit in its most complete form.
57
TCCE-THCE MODEL
114
117
121
126
70
TCCE-TCPE-THCE-THPE 130270
Cooling capacity: 30.166.3 kW - Heating capacity: 34.977.1 kW
Packaged air-cooled water chillers and reversible heat pumps with centrifugal fans. Range with hermetic Scroll compressors and R407C refrigerant gas.
Construction features
Compressor: hermetic rotary Scroll compressor. Water side heat exchanger: stainless steel plate exchanger with closed cell polyurethane foam rubber insulation, complete with water ow dierential pressure switch. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: centrifugal electric fans with external motor, belt transmission and adjustable pulley. The condensation air supply is horizontal (suction side). Control: microprocessor electronic control. Structure: load-bearing galvanized and painted sheet steel structure with epoxy powder coating and compressor compartment lined internally with soundproong material.
TANK&PUMP with integrated buer tank from 80 to 150 litres and single or double pump. PUMP with pumps for primary circuit or for primary circuits and secondary circuits. CC for unit operation in cooling mode, with outdoor air temperature up to 10 C. LOW AMBIENT (TCCE-TCPE only) for unit operation with low external air temperature (down to 10C). Vertical condensation air supply. Protection coil grilles Refrigerant circuit high and low pressure gauges. Evaporator antifreeze electric heater.
Versions
B - Standard version with standard fans (TCCEB-THCEB) and highpressure fans (TCPEB-THPEB).
Models
TCCEB: unit designed for cooling only. THCEB: heat pump unit. TCPEB: unit designed for cooling only. THPEB: heat pump unit.
Built-in pump assembly complete with: water buer tank, circulation pump, expansion tank, pressure gauge, bleed and safety valve and water drain. The pump is available in a single or double conguration, including one in stand-by, and in 4 sizes for combination with the TCCE-TCPE and THCE-THPE units.
PUMP ACCESSORY
Version tted with a maximum of 3 pumps: P - Primary circuit pump in single conguration. DP - Primary circuit pump in double conguration, with one in stand-by. PU - Secondary circuit pump in single conguration. DPU - Secondary circuit pump in double conguration, in combination with primary circuit pump.
COOLING ONLY
HEAT PUMP
INDOOR INSTALLATION
71
Nominal cooling capacity Nominal heating capacity Sound pressure level Scroll/step compressor Circuits Fan nominal air flow Fan max. available static pressure Absorbed power TCCEB Absorbed power THCEB Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCCEB-TCPEB Weight THCEB-THPEB
30,1 34,9 54 1/1 1 8.500 145 12,1 11,4 400-3+N-50 130 1.855 1.916 910 646 669
34,5 41,2 59 1/1 1 11.000 155 14,5 13,8 400-3+N-50 135 1.855 1.916 910 666 687
37,3 43,1 57 1/1 1 15.000 125 14,9 13,6 400-3+N-50 140 2.355 1.916 1.010 781 805
47,2 55,9 57 1/1 1 15.000 125 18,7 17,8 400-3+N-50 150 2.355 1.916 1.010 885 910
59,4 65,3 60 1/1 1 17.000 150 22,9 21,5 400-3+N-50 160 2.355 1.916 1.010 946 982
66,3 77,1 64 2/2 1 20.000 28,8 28,8 400-3+N-50 270 2.355 1.010 1.022 1.057 1.916
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Air: 35C - Water: 7/12C. Air: 7C D.B. - 6C W.B. - Water: 40/45C. At 5 m from the unit in free eld (Q = 1), with ducted fans. The weight refers to the unit in its most complete form.
155
130
135
140
150
160
270
TCCETY-THCETY 2332160
Cooling capacity: 32161 kW - Heating capacity: 37175 kW
GREEN LINE
Range with excellent energy eciency (class A) Plug-Fan-type centrifugal fans with EC motor (brushless) 3 capacity steps ESEER up to 6.02 (*)
THCETY 2130 TCCETY 233
High eciency air-cooled water chillers and reversible heat pumps with Plug-Fans and EC motors. Range with hermetic Scroll compressors and R410A refrigerant.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection and crankcase heater. 2 or 3 capacity steps depending on the models, which allow excellent load modulation with high energy eciency at partial loads. Water side heat exchanger: stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water ow dierential pressure switch. Air side heat exchanger: nned coil exchanger, with copper pipes and aluminium ns. Plug-Fan-type centrifugal electric fans with EC motors, tted with internal thermal protection, set out in a single row with a horizontal outlet. Horizontal condensation/evaporation air outlet on the opposite side of the nned coil or vertical supply can be easily transformed on site. Electronic proportional device for continuous adjustment of the fan rotation speed, up to a minimum outdoor air temperature of -15C when operating as a chiller, and up to a maximum outdoor air temperature of 40C when operating as a heat pump. Control: microprocessor electronic control with Adaptive Function Plus logic that allows high energy eciency to be obtained at partial loads and set up for connection with the main BMS on the market (MODBUS RTU). Load-bearing structure and panels in galvanised and RAL 9018 painted sheet metal; galvanised steel sheet metal base
Versions
Models
TCCETY: unit for cooling only. THCETY: reversible heat pump unit.
PUMP with single or double pump, including an automatic pump in standby, complete with expansion tank, safety valve and water pressure gauge. The pumps are available in the low of high pressure versions. TANK&PUMP with built-in buer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. Desuperheater. 100% heat recovery. Electronic expansion valve. Power factor correction capacitors (cos > 0.91). Soft starter. Compressor soundproong. Refrigerant circuit high and low pressure gauges. Copper/copper or copper/pre-painted aluminium coils. Digital input for double set-point. 4-20 mA analogue input for shifting set-point. Evaporator antifreeze heater, buer tank, pumps and heat exchangers for heat recovery if present. Serial interface for connection with external BMS.
COOLING ONLY
HEAT PUMP
INDOOR INSTALLATION
73
Nominal cooling capacity E.E.R. Absorbed power (*) E.S.E.E.R. E.S.E.E.R.+ THCETY MODEL Nominal heating capacity C.O.P. Absorbed power in winter mode Nominal cooling capacity E.E.R. (EN 14511:2004) (***) C.O.P. (EN 14511:2004) (***) Sound power level Scroll/step compressor Circuits Fan nominal air flow Fan maximum available static pressure Electrical supply DIMENSIONS L - Width H - Height P - Depth
kW kW
38,8 3,65 13,2 6,02 6,72 238 41,7 3,93 13,3 38,8 4,25 5,25 82 2/2 1 13.000 250 400-3+N-50 238 2.600 1.980 870
44,2 2,90 17,9 5,59 6,48 245 47,8 3,33 17,1 42,6 3,78 4,73 83 2/3 1 13.000 250 400-3+N-50 245 2.600 1.980 870
51,3 3,06 22,4 5,14 5,94 250 55,8 3,58 21,3 50,6 3,88 4,92 85 2/3 1 26.000 250 400-3+N-50 250 2.600 1.980 870
59,2 3,05 25,0 5,33 6,13 260 62,2 3,52 23,4 58,1 3,80 4,73 85 2/3 1 26.000 250 400-3+N-50 260 2.600 1.980 870
64,0 3,01 26,9 5,36 6,28 265 67,9 3,31 26,2 61,9 3,80 4,66 85 2/3 1 26.000 250 400-3+N-50 265 2.600 1.980 870
70,3 3,27 27,0 5,56 6,42 270 3,74 26,9 69,4 3,82 4,93 2/3 1 26.000 250 400-3+N-50 270 1.980 1.100 3.600 85 79,0
3,43 kW kW 13,8 32,5 3,47 4,70 dB(A) no. no. m /h Pa V-ph-Hz mm mm mm 82 2/2 1 13.000 250 400-3+N-50 233 2.600 1.980 870
TCCETY MODEL Nominal cooling capacity E.E.R. Absorbed power (*) E.S.E.E.R. E.S.E.E.R.+ THCETY MODEL Nominal heating capacity C.O.P. Absorbed power in winter mode Nominal cooling capacity E.E.R. (EN 14511:2004) (***) C.O.P. (EN 14511:2004) (***) Sound power level Scroll/step compressor Circuits Fan nominal air flow Fan maximum available static pressure Electrical supply DIMENSIONS L - Width H - Height P - Depth mm mm mm dB(A) no. no. m /h Pa V-ph-Hz kW kW kW kW kW
280 79,5 3,28 29,7 6,02 6,97 280 86,0 3,85 28,1 77,7 3,88 5,06 85 2/2 1 26.000 250 400-3+N-50 280 3.600 1.980 1.100
290 88,0 3,12 33,8 5,86 6,79 290 96,0 3,59 32,7 85,2 3,60 4,71 86 2/3 1 27.000 250 400-3+N-50 290 3.600 1.980 1.100
2100 101,2 3,15 40,5 5,74 6,63 2100 111,0 3,69 38,8 99,3 3,65 4,84 88 2/3 1 39.000 250 400-3+N-50 2100 3.600 1.980 1.100
2115 114,5 3,33 42,7 5,43 6,30 2115 122,0 3,71 41,6 111,0 3,83 4,88 88 2/3 1 39.000 250 400-3+N-50 2115 4.400 2.330 1.100
2130 126,0 3,24 47,0 5,42 6,24 2130 139,0 3,75 45,7 123,8 3,74 4,88 88 2/2 1 39.000 250 400-3+N-50 2130 4.400 2.330 1.100
2145 143,0 3,32 54,2 5,32 6,13 2145 157,0 3,73 53,7 141,3 3,79 4,86 89 2/3 1 52.000 250 400-3+N-50 2145 4.400 2.330 1.100
2160 161,0 60,4 5,37 6,19 2160 175,0 3,66 159,8 3,71 4,78 89 2/2 1 52.000 250 400-3+N-50 2160 4.400 2.330 1.100 59,4 3,26
(***) Energy indices for THCETY versions without accessories, calculated in compliance with that envisaged by EN 14511: 2004, in the conditions prescribed by the Finance Act, Italian market.
TERMINAL UNITS
In the following conditions: Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B. - Water: 40/45C. Measured in accordance with EN 14511 05/11 with Air: 35C - Water: 12/7C and ESP: 250 Pa. Measured in accordance with EN 14511 05/11 with Air: 7C D.B. - 6C W.B.- Water: 40/45C and ESP: 250 Pa. Total sound power level in dB(A) on the basis of measurements taken in accordance with RS S/C/005-2009 and UNI EN-ISO 9614. ESEER (European Seasonal EER) - Average European seasonal eciency measured in accordance with EN 14511 05/11. ESEER with Adaptive Function Plus software measured in accordance with EN 14511 05/11.
SYSTEM ACCESSORIES
CONDENSING UNITS
kW
37,5
TCCETY MODEL
233
238
245
250
260
265
270
TCHEY-THHEY 105112
Cooling capacity: 5.412 kW - Heating capacity: 6.513.9 kW
ESEER with Adaptive Function Plus up to 4.5 Extremely compact and silent units
Packaged water-cooled water chillers and reversible heat pumps on the cooling circuit. Range with hermetic Scroll compressors and R410A refrigerant gas.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection. Primary side heat exchanger (user): adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch. Ground water or city water pipe side heat exchanger (disposal unit): adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch (for THHEY). Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. Structure: in galvanised and painted sheet steel with polyester powder coating, complete with soundproofed compressor compartment.
Pressure switch valve Pressure switch valve and bypass solenoid valve (only THHEY). Water circuit heat pump (for TCHEY only). Digital input for double set-point 4-20mA analogue input for shifting set-point.
Models
TCHEY: unit designed for cooling only. THHEY: heat pump unit.
STANDARD unit
Without circulation pump. Primary side (user): expansion tank with membrane, safety valve, water drain valve, manual air bleed valve, pressure gauge.
Water buer tank Buer connection pipes Water lter. Antivibration rubber mountings. Antifreeze electric heater on the buer tank. Low pressure switch. 3-way valve for the production of hot water. External air temperature probe for set-point compensation. Additional electric heater for heat pump, managed by regulation. Remote keyboard with display. Clock card Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management.
PUMP unit
With circulation pump. Primary side (user): pump assembly complete with electric circulation pump, membrane expansion tank, safety valve, water drain valve, manual air bleed valve, pressure gauge.
COOLING ONLY
HEAT PUMP
INDOOR INSTALLATION
75
E.E.R. E.S.E.E.R. E.S.E.E.R.+ Absorbed power (*) Nominal heating capacity C.O.P. Absorbed power (*) Nominal cooling capacity (radiating) E.E.R. (radiating) Absorbed power (radiating) (*) Heating capacity (radiating) C.O.P. (radiating) C.O.P. (**) Absorbed power (radiating) (*) Heating capacity (geothermal) C.O.P. (geothermal) Absorbed power (geothermal) (*) Sound pressure level Scroll/step compressor Circuits Water buffer tank content KA Available head pressure of pump Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height STANDARD - PUMP H - Height STANDARD - PUMP + KA P - Depth Weight TCHEY P Weight THHEY P Weight KA mm mm mm mm kg kg kg kW dB(A) no. no. l kPa V-ph-Hz kW kW kW kW kW kW kW kW
3,47 3,54 4,00 1,56 6,5 3,18 2,04 7,7 5,30 1,5 7,4 5,04 4,40 1,5 5,1 3,40 1,5 49,1 1/1 1 20 47 230-1-50 105 585 535 855 386 75 78 28
3,20 3,76 4,25 2,12 8,2 2,84 2,88 10,5 5,02 2,1 9,6 4,82 4,42 2,0 6,7 2,91 2,3 51,1 1/1 1 20 55 230-1-50 400-3+N-50 107 585 535 855 386 80 83 28
3,40 3,95 4,46 2,74 10,8 3,05 3,54 13,6 5,04 2,7 12,6 4,81 4,40 2,6 8,3 3,07 2,7 51,3 1/1 1 30 82 230-1-50 400-3+N-50 109 660 535 855 420 90 94 33
3,33 3,91 4,34 3,60 13,9 4,38 17,8 4,86 3,7 14,9 4,42 3,2 11,0 3,33 3,3 53,1 1 30 78 230-1-50 400-3+N-50 112 660 535 855 420 93 97 33 1/1 4,72
TERMINAL UNITS
SYSTEM ACCESSORIES
In the following conditions: Chilled water: 12/7C. - Condenser water: 30/35C. Hot water: 40/45C. - Evaporator water: 10C. - Water ow rate as in summer operation. Chilled water 23/18C - Condenser water: 30/35C. Hot water: 30/35C. - Evaporator water: 10C. - Water ow rate as in summer operation. Hot water: 30/35C. - Evaporator water: 0/3C, 30% glycol. 1 m from the unit in free eld (Q = 2). The weight refers to the unit in its most complete form.
ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software. (*) STANDARD unit. (**) Reference for the tax credit for the French market. KA = Water buer tank. KTC = Connection pipes.
CONDENSING UNITS
3,17
kW
5,4
6,8
9,3
12,0
TCHEY-THHEY MODEL
105
107
109
112
TCHEY-THHEY 115240
Cooling capacity: 15.541.9 kW - Heating capacity: 17.444.9 kW
CLASS A unit (radiant applications) Applications with ground or city water or geothermal probes Plug&Play unit with hydraulic connections on the top
Packaged water-cooled water chillers and reversible heat pumps on the cooling circuit. Range with hermetic Scroll compressors and R410A refrigerant gas.
Construction features
Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. Primary side heat exchanger (user): adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch. Disposal unit side exchanger (ground water/city water geothermal probes): adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch (for THHEY). Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. Structure: in galvanised and painted sheet steel, with polyester powder coating, covered internally with soundproong panelling. Disposal unit side (dry cooler/geothermal probes): pump assembly complete with phase cutting pump, water supply/drainage valve, manual air bleed valve.
Silenced installation. Pressure switch valve with water ow blocking solenoid. Pressure switch valve with water ow blocking solenoid and bypass solenoid valve. Water circuit heat pump (for TCHEY only). Soft-start device. Water low set-point temperature. Digital input for double set-point. 4-20 mA analogue input for shifting set-point.
Models
TCHEY: unit designed for cooling only. THHEY: heat pump unit.
Without circulation pump and hydraulic accessories. With circulation pump. Primary side (user): pump assembly complete with electric circulation pump with standard or increased static pressure, membrane expansion tank, safety valve, water drain valve, manual air bleed valve, pressure gauge.
3-way valve for the production of hot water. Additional electric heater for heat pump, managed by regulation. External air temperature probe for set-point compensation. Free-Cooling kit. Water lter. Antivibration rubber mountings. Remote keyboard with display. Clock card. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management.
COOLING ONLY
HEAT PUMP
INDOOR INSTALLATION
77
Absorbed power TCHEY (*) E.E.R. TCHEY E.S.E.E.R. E.S.E.E.R.+ Heating capacity THHEY Absorbed power (*) C.O.P. Heating capacity THHEY Absorbed power (*) C.O.P. C.O.P. (**) (***) Heating capacity (geothermal) THHEY Absorbed power (geothermal) (*) C.O.P. (geothermal) C.O.P. (***) Cooling capacity TCHEY/THHEY Absorbed power TCHEY (*) E.E.R. TCHEY E.E.R. THHEY (***) Sound power level Scroll/step compressor Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height STANDARD - PUMP P - Depth Weights TCHEY Weights THHEY
kW
3,4 5,43 6,18 6,80 20,07 4,3 4,65 21,36 3,4 6,20 6,04 16,10 3,50 4,60 4,55 25,88/22,98 3,5 7,31 5,54 53 1/1 1 79/141 400-3+N-50 118 700 1.100 560 189 193
4,4 5,19 6,10 6,77 24,96 5,5 4,56 26,50 4,3 6,11 5,99 19,50 4,10 4,76 4,72 31,80/27,94 4,6 6,85 5,45 57 1/1 1 75/163 400-3+N-50 122 700 1.100 780 227 230
4,9 5,37 6,15 6,83 28,76 6,2 4,65 30,64 4,9 6,23 6,10 22,50 4,80 4,69 4,65 36,67/32,21 5,2 6,99 5,42 58 1/1 1 110/135 400-3+N-50 125 700 1.100 780 250 254
6,5 4,70 5,51 6,17 35,73 7,9 4,53 38,29 6,4 5,94 5,78 28,6 6,5 4,40 4,35 43,50/39,02 6,7 6,46 5,50 59 2/2 1 98/119 400-3+N-50 230 700 1.100 780 273 278
7,9 5,30 6,17 6,91 44,91 4,53 47,72 7,9 6,05 5,90 7,7 4,60 4,55 59,06/50,78 8,4 6,99 62 2/2 1 101/127 400-3+N-50 240 700 1.100 780 293 298 5,36 35,4
kW kW kW kW
kW
kW kW
In the following conditions: Chilled water: 12/7C. - Condenser water: 30/35C. Hot water: 40/45C. - Evaporator water: 10C. - Water ow rate as in summer operation. Hot water: 30/35C. - Evaporator water: 10/7C. Hot water: 30/35C. - Evaporator water: 0/3C, 30% glycol. Chilled water: 23/18C. - Condenser water: 30/35C. Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614, with silenced conguration.
(*) STANDARD unit. (**) Reference for the tax credit for the French market. (***) Energy indices for standard congurations, calculated in compliance with that envisaged by EN 14511: 2004 Standard, in the conditions prescribed by the Finance Act, Italian market.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
The weight refers to the unit in its most complete form. ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software.
kW
14,10
9,9
kW
15,58/13,98
18,49/16,42
22,83/20,06
26,36/23,16
30,58/27,44
41,89/36,02
TCHEY-THHEY MODEL
115
118
122
125
230
240
TCHEY-THHEY 2454450
Cooling capacity: 45.2450.8 kW - Heating capacity: 50512.7 kW
CLASS A unit (radiant applications) Applications with ground or city water or geothermal probes Wide range of equipment and accessories
THHEY 4260 TCHEY 2100
Packaged water-cooled water chillers and reversible heat pumps on the cooling circuit. Range with hermetic Scroll compressors and R410A refrigerant gas.
Construction features
Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. Primary side heat exchanger (user): adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch. Disposal unit side exchanger (ground water/city water geothermal probes): adequately insulated stainless steel plate exchanger, complete with antifreeze heater and water ow dierential pressure switch (for THHEY). Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function Plus logic. Structure: in galvanised and painted sheet steel, with polyester powder coating.
Plant-system PUMP (dry cooler/geothermal probes): with inverter driven single or double pump, including an automatic pump in stand-by. Desuperheater. 100% heat recovery (mod. 2454360). Water circuit heat pump (for TCHEY only). Soft-start device. Electronic expansion valve (standard for mod. 4410-4450). Refrigerant circuit high and low pressure gauges. Silenced installation. Water low set-point temperature. Digital input for double set-point. 0-10V analogue input for condensation control performed by external device. 4-20 mA analogue input for shifting set-point. Serial interfaces for connection to external BMS.
Versions
Models
TCHEY: unit designed for cooling only. THHEY: heat pump unit.
Primary side (user) PUMP: with single or double pump, including an automatic pump in standby, complete with expansion tank, safety valve, water charge/drain valve, air bleed valve, pressure gauge. The pumps are available in the low or high pressure versions.
Modulating 3-way valve for condensation control. Modulating 2-way valve for condensation control. External air temperature probe for set-point compensation. Free-Cooling kit (mod. 2452185). Water lter. Antivibration rubber mountings. Remote keyboard with display. Clock card. Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management.
The units ca be equipped up to a maximum of 2 pumps in mod. 2452185 and 4 pumps in mod. 41804450. In presence of recovery or desuperheater, the PUMP conguration is not envisioned.
YFL2 YFL3
COOLING ONLY
HEAT PUMP
INDOOR INSTALLATION
79
Absorbed power TCHEY E.E.R. TCHEY E.S.E.E.R. E.S.E.E.R.+ Heating capacity THHEY kW Absorbed power C.O.P. E.E.R. (**) C.O.P. (**) Sound power level Scroll/step compressor Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width L - Width H - Height P - Depth
kW
11,16 4,78 6,73 7,62 58,84 13,72 4,29 5,68 5,60 67 2/2 1 250 1.000 1.250 1.400 870
12,89 4,70 6,78 7,68 67,59 15,66 4,32 5,60 5,53 68 2/2 1 260 1.000 1.250 1.400 870
14,73 4,69 6,52 7,39 75,41 17,42 4,33 5,61 5,56 68 2/2 1 270 1.000 1.250 1.400 870
16,16 4,70 6,63 7,42 83,66 19,55 4,28 5,47 5,56 69 2/3 1 275 1.000 1.250 1.400 870
18,78 4,80 6,45 7,23 101,76 23,41 4,35 5,36 5,41 70 2/2 1 290 1.000 1.250 1.400 870
21,98 4,69 6,32 7,10 116,26 27,13 4,29 5,43 5,31 71 2/3 1 2100 1.250 1.500 1.550 870
25,18 4,66 6,30 7,08 133,25 31,04 4,29 5,52 5,37 72 2/3 1 2115 1.250 1.500 1.550 870
28,47 4,60 6,16 6,91 147,33 34,89 4,22 5,52 5,23 73 2/3 1 2130 1.250 1.500 1.550 870
31,31 4,65 6,14 6,89 162,82 38,90 4,19 5,58 5,26 74 2/2 1 2145 1.250 1.500 1.550 870
36,42 4,54 6,14 6,91 186,13 45,21 4,12 5,61 5,17 74 2/3 1 2165 1.250 1.500 1.550 870
41,27 4,48 5,97 6,71 208,84 4,07 5,40 5,10 75 2/2 1 2185 1.250 1.500 1.550 870
4,16 5,66 5,55 dB(A) no. no. 67 2/2 1 245 mm mm mm mm 1.000 1.250 1.400 870
V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50
TCHEY-THHEY MODEL Cooling capacity TCHEY/THHEY kW Absorbed power TCHEY E.E.R. TCHEY E.S.E.E.R. E.S.E.E.R.+ Heating capacity THHEY kW Absorbed power C.O.P. E.E.R. (**) C.O.P. (**) Sound power level Scroll/step compressor Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width L - Width H - Height P - Depth mm mm mm mm dB(A) no. no. kW kW
4180 37,00 4,90 6,00 6,78 201,28 43,36 4,64 5,49 5,78 77 4/4 2 4180 2.509 3.734 1.855 870
4205 42,30 4,90 6,20 7,03 229,88 50,54 4,55 5,45 5,64 77 4/4 2 4205 2.509 3.734 1.855 870
4235 47,58 4,90 6,36 7,19 258,02 57,62 4,48 5,43 5,52 78 4/4 2 4235 2.509 3.734 1.855 870
4260 53,42 4,88 6,35 7,12 290,86 64,74 4,49 5,38 5,50 79 4/4 2 4260 2.509 3.734 1.855 870
4290 59,20 4,87 6,34 7,13 322,44 71,72 4,50 5,34 5,49 80 4/4 2 4290 2.509 3.734 1.855 870
4330 68,32 4,79 6,26 7,07 367,46 82,96 4,43 5,16 5,41 81 4/4 2 4330 2.509 3.734 1.855 870
4360 77,68 4,69 6,11 6,94 411,96 94,14 4,38 5,10 5,32 82 4/4 2 4360 2.509 3.734 1.855 870
4410 89,24 4,58 5,87 6,63 462,16 107,40 4,30 5,10 5,22 83 4/4 2 4410 2.509 3.734 1.855 870
4450 101,20 4,45 5,50 512,72 120,82 4,24 84 2 4450 2.509 3.734 1.855 870 4/4 6,16
V-ph-Hz 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50
(**) Energy indices calculated in compliance with that envisaged by EN 14511: 2004 Standard, in the conditions prescribed by the Finance Act, Italian market.
TERMINAL UNITS
In the following conditions: Chilled water: 12/7C. - Condenser water: 30/35C. Hot water: 40/45C. - Evaporator water: 10C. - Water ow rate as in summer operation. Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. Width referring to the unit with standard conguration or supplied with "recovery" or "desuperheater" accessories. Width referring to the PUMP unit, up to a maximum of 2 pumps in mod. 2452185 (2 user side or disposal unit side pumps or 1 user side pump + 1 disposal unit side pump) and up to a maximum of 4 pumps in mod. 41804450 (2 user side and 2 disposal unit side pumps). ESEER (European Seasonal EER) - Average European seasonal eciency. ESEER with Adaptive Function Plus software.
SYSTEM ACCESSORIES
CONDENSING UNITS
kW
12,03
51,33
45,2/41,4
53,3/48,7
60,6/55,4
69,2/63,2
75,9/69,4
90,1/82,3
TCHEY-THHEY MODEL
245
250
260
270
275
290
2100
2115
2130
2145
2165
2185
Z-Flow Range
80
Eciency range in CLASS A with EER >5.05 33 sizes up to more than 1,600 kW Wide range of standard equipment
Packaged water-cooled water chillers. Range with semi-hermetic screw compressors and R134a refrigerant gas.
Construction features
Compressor: high energy eciency semi-hermetic screw compressor, with part-winding or star-delta limited start (depending on model) and complete with thermal protection, crankcase heater and compressor discharge shut-o valve. Electronic expansion valve: as standard on all models. Water side heat exchanger (evaporator): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water ow dierential pressure switch and Victaulic connections. Water side heat exchanger (condenser): shell and tube complete with safety valve, and service valve on the high-pressure refrigerant circuit. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - clock card for displaying date/time and machine time band management.
Models
TCHVBZ: unit designed for cooling only. TCHVIZ: soundproofed unit designed for cooling only.
Desuperheater. 100% heat recovery. Thermostat with display for the heat recovery/desuperheater. Prepared for heat pump function. Power factor correction capacitors (cos > 0.94). Thermal overload switches Forced limit of the power consumption. Inlet compressor shut-o valves Linear capacity control compressors (50-100 % for each compressor). Evaporator antifreeze electric heater. Digital input for double set-point Display of refrigerant circuit high/low pressure. Compressor oil level sensor. Control of min/max power supply voltage. 0-10V analogue input for condensation control performed by external device. 4-20 mA analogue input for shifting set-point. Serial interface for connection with external BMS.
Versions
B -Standard version (TCHVBZ). I -Soundproofed version with soundproofed compressor cover (TCHVIZ).
Spring antivibration mountings. Antivibration rubber mountings. Remote keyboard with display. Rhoss sequencer for the integrated management of several water chillers.
C3FZ C3FE
COOLING ONLY
INDOOR INSTALLATION
81
mm mm mm kg kg
In the following conditions: Chilled water: 7/12C - Condenser input water: 30/35C. Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. Empty weight.
ESEER (European Seasonal EER) - Average European seasonal eciency. TCHVIZ soundproofed version.
TERMINAL UNITS
TCHVBZ-TCHVIZ MODEL Nominal cooling capacity E.E.R. E.S.E.E.R. Absorbed power Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCHVBZ Weight TCHVIZ
kW
31301 1.308 5,20 6,06 251,6 101 99 3/9 3 400-3-50 31301 4.940 2.220 1.700 6.795 7.395
31351 1.356 5,15 6,01 263,4 101 99 3/9 3 400-3-50 31351 4.940 2.220 1.700 6.827 7.427
31401 1.406 5,11 6,05 275,1 101 99 3/9 3 400-3-50 31401 4.940 2.220 1.700 6.852 7.452
31461 1.463 5,10 6,00 286,8 102 100 3/9 3 400-3-50 31461 4.940 2.220 1.700 6.891 7.491
31521 1.524 5,11 6,02 298,3 102 100 3/9 3 400-3-50 31521 4.940 2.220 1.700 6.980 7.580
31591 1.583 5,12 6,01 309,2 102 100 3/9 3 400-3-50 31591 4.940 2.220 1.700 7.068 7.668
31631 1.635 5,11 6,02 320,1 102 100 3/9 3 400-3-50 31631 4.940 2.220 1.700 7.157 7.757
SYSTEM ACCESSORIES
TCHVBZ-TCHVIZ MODEL Nominal cooling capacity E.E.R. E.S.E.E.R. Absorbed power Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCHVBZ Weight TCHVIZ
kW
mm mm mm kg kg
CONDENSING UNITS
2781 778 5,06 5,86 153,8 99 97 2/6 2 400-3-50 2781 4.120 1.840 1.300 3.920 4.350
2841 839 5,05 5,89 166,1 99 97 2/6 2 400-3-50 2841 4.000 1.840 1.300 4.406 4.836
2901 901 5,05 6,03 178,4 99 97 2/6 2 400-3-50 2901 4.000 1.910 1.300 4.636 5.066
2961 958 5,05 5,99 189,8 99 97 2/6 2 400-3-50 2961 4.000 1.910 1.300 4.669 5.099
21031 1.029 5,07 5,98 203 99 97 2/6 2 400-3-50 21031 4.000 1.950 1.300 4.779 5.209
21111 1.109 5,16 6,02 215 99 97 2/6 2 400-3-50 21111 4.000 1.950 1.300 4.870 5.300
21181 1.181 5,19 5,98 227,5 99 97 2/6 2 400-3-50 21181 4.000 1.950 1.300 5.008 5.438
21261 1.258 5,20 5,97 242 99 97 2/6 2 400-3-50 21261 4.000 1.950 1.300 4.934 5.364
TCHVBZ-TCHVIZ MODEL Nominal cooling capacity E.E.R. E.S.E.E.R. Absorbed power Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCHVBZ Weight TCHVIZ
kW
mm mm mm kg kg
2411 407 5,06 5,93 80,5 97 95 2/6 2 400-3-50 2411 3.880 1.840 1.300 2.386 2.816
2431 435 5,06 5,85 86,0 97 95 2/6 2 400-3-50 2431 3.880 1.840 1.300 2.413 2.843
2461 462 5,05 5,82 91,4 97 95 2/6 2 400-3-50 2461 4.000 1.840 1.300 2.458 2.888
2511 514 5,05 5,85 101,9 99 97 2/6 2 400-3-50 2511 4.070 1.960 1.300 2.953 3.383
2561 565 5,06 5,99 111,7 99 97 2/6 2 400-3-50 2561 4.070 1.960 1.300 3.297 3.727
2601 599 5,07 6,01 118,1 99 97 2/6 2 400-3-50 2601 4.070 1.960 1.300 3.320 3.750
2631 629 5,06 5,98 124,3 99 97 2/6 2 400-3-50 2631 4.070 1.960 1.300 3.337 3.767
2681 677 5,08 5,90 133,4 99 97 2/6 2 400-3-50 2681 4.070 1.960 1.300 3.404 3.834
2711 715 5,05 5,88 141,6 99 97 2/6 2 400-3-50 2711 4.070 1.960 1.300 3.447 3.877
TCHVBZ-TCHVIZ MODEL Nominal cooling capacity E.E.R. E.S.E.E.R. Absorbed power Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCHVBZ Weight TCHVIZ
mm mm mm kg kg
kW
1201 204 5,06 6,00 40,4 94 92 1/3 1 400-3-50 1201 3.460 1.460 1.000 1.343 1.598
1231 231 5,05 5,83 45,7 94 92 1/3 1 400-3-50 1231 3.460 1.460 1.000 1.369 1.624
1281 283 5,07 5,84 55,9 97 95 1/3 1 400-3-50 1281 3.440 1.460 1.000 1.715 1.970
1311 309 5,05 5,80 61,1 97 95 1/3 1 400-3-50 1311 3.440 1.460 1.000 1.733 1.988
1351 354 5,05 6,00 70,1 97 95 1/3 1 400-3-50 1351 3.450 1.640 1.000 1.885 2.140
1421 418 5,05 6,01 82,8 97 95 1/3 1 400-3-50 1421 3.450 1.640 1.000 2.374 2.629
1481 480 5,05 5,87 95,0 97 95 1/3 1 400-3-50 1481 3.450 1.640 1.000 2.413 2.668
1531 535 5,05 5,83 105,9 98 96 1/3 1 400-3-50 1531 3.450 1.740 1.000 2.662 2.917
1611 608 5,06 6,03 120,3 98 96 1/3 1 400-3-50 1611 3.450 1.740 1.000 2.697 2.952
Z-Flow Range
82
TCHVZ 120031630
Cooling capacity: 199.71.629.2 kW
Eciency range with EER >4.75 33 sizes up to more than 1,600 kW Heat pump unit with water production up to 55C
TCHVBZ 2710
Packaged water-cooled water chillers. Range with semi-hermetic screw compressors and R134a refrigerant gas.
Construction features
Compressor: high energy eciency semi-hermetic screw compressor, with part-winding or star-delta limited start (depending on model) and complete with thermal protection, crankcase heater and compressor discharge shut-o valve. Electronic expansion valve: as standard on all models. Water side heat exchanger (evaporator): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water ow dierential pressure switch and Victaulic connections. Water side heat exchanger (condenser): shell and tube complete with safety valve, and service valve on the high-pressure refrigerant circuit. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - clock card for displaying date/time and machine time band management.
Models
TCHVBZ: unit designed for cooling only. TCHVIZ: soundproofed unit designed for cooling only.
Desuperheater. 100% heat recovery. Thermostat with display for the heat recovery/desuperheater. Prepared for heat pump function. Power factor correction capacitors (cos > 0.94). Thermal overload switches Forced limit of the power consumption. Inlet compressor shut-o valves Linear capacity control compressors (50-100 % for each compressor). Evaporator antifreeze electric heater. Digital input for double set-point Display of refrigerant circuit high/low pressure. Compressor oil level sensor. Control of min/max power supply voltage. 0-10V analogue input for condensation control performed by external device. 4-20 mA analogue input for shifting set-point. Serial interface for connection with external BMS.
Versions
B -Standard version (TCHVBZ). I -Soundproofed version with soundproofed compressor cover (TCHVIZ).
Spring antivibration mountings. Antivibration rubber mountings. Remote keyboard with display. Rhoss sequencer for the integrated management of several water chillers.
C1FZ C2FZ
COOLING ONLY
INDOOR INSTALLATION
83
mm mm mm kg kg
In the following conditions: Chilled water: 7/12C - Condenser input water: 30/35C. Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. Empty weight.
ESEER (European Seasonal EER) - Average European seasonal eciency. TCHVIZ soundproofed version.
TERMINAL UNITS
TCHVBZ-TCHVIZ MODEL Nominal cooling capacity E.E.R. E.S.E.E.R. Absorbed power Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCHVBZ Weight TCHVIZ
kW
31300 1.282,9 4,98 6,00 257,7 101 99 3/9 3 400-3-50 31300 4.940 2.220 1.700 6.735 7.335
31350 1.330,0 4,93 5,89 270,0 101 99 3/9 3 400-3-50 31350 4.940 2.220 1.700 6.767 7.367
31390 1.377,2 4,87 5,87 282,9 101 99 3/9 3 400-3-50 31390 4.940 2.220 1.700 6.792 7.392
31460 1.437,5 4,87 5,83 295,4 102 100 3/9 3 400-3-50 31460 4.940 2.220 1.700 6.831 7.431
31520 1.518,5 4,91 5,90 309,0 102 100 3/9 3 400-3-50 31520 4.940 2.220 1.700 6.920 7.520
31590 1.580,8 4,91 5,89 321,7 102 100 3/9 3 400-3-50 31590 4.940 2.220 1.700 7.008 7.608
31630 1.629,2 4,87 5,90 334,2 102 100 3/9 3 400-3-50 31630 4.940 2.220 1.700 7.097 7.697
SYSTEM ACCESSORIES
TCHVBZ-TCHVIZ MODEL Nominal cooling capacity E.E.R. E.S.E.E.R. Absorbed power Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCHVBZ Weight TCHVIZ
kW
mm mm mm kg kg
CONDENSING UNITS
2750 742,0 4,88 5,69 152,0 99 97 2/6 2 400-3-50 2750 4.120 1.840 1.300 3.880 4.310
2790 787,0 4,83 5,72 162,8 99 97 2/6 2 400-3-50 2790 4.000 1.840 1.300 4.366 4.796
2880 879,1 4,92 5,98 178,7 99 97 2/6 2 400-3-50 2880 4.000 1.910 1.300 4.596 5.026
2930 927,2 4,81 5,82 192,8 99 97 2/6 2 400-3-50 2930 4.000 1.910 1.300 4.629 5.059
21030 1.016,6 4,84 5,81 210,0 99 97 2/6 2 400-3-50 21030 4.000 1.950 1.300 4.739 5.169
21110 1.087,3 4,88 5,96 222,8 99 97 2/6 2 400-3-50 21110 4.000 1.950 1.300 4.830 5.260
21180 1.155,8 4,92 5,86 2,34,9 99 97 2/6 2 400-3-50 21180 4.000 1.950 1.300 4.878 5.308
21260 1.208,4 4,87 5,85 248,0 99 97 2/6 2 400-3-50 21260 4.000 1.950 1.300 4.914 5.344
TCHVBZ-TCHVIZ MODEL Nominal cooling capacity E.E.R. E.S.E.E.R. Absorbed power Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCHVBZ Weight TCHVIZ
kW
mm mm mm kg kg
2400 391,7 4,90 5,70 80,0 97 95 2/6 2 400-3-50 2400 3.880 1.840 1.300 2.366 2.796
2420 413,0 4,81 5,68 85,8 97 95 2/6 2 400-3-50 2420 3.880 1.840 1.300 2.393 2.823
2440 432,0 4,75 5,60 91,0 97 95 2/6 2 400-3-50 2440 4.000 1.840 1.300 2.438 2.868
2510 506,8 4,80 5,68 105,6 99 97 2/6 2 400-3-50 2510 4.070 1.960 1.300 2.923 3.353
2560 550,8 4,94 5,93 111,5 99 97 2/6 2 400-3-50 2560 4.070 1.960 1.300 3.257 3.687
2600 592,0 4,92 5,95 120,3 99 97 2/6 2 400-3-50 2600 4.070 1.960 1.300 3.280 3.710
2630 621,6 4,93 5,83 126,1 99 97 2/6 2 400-3-50 2630 4.070 1.960 1.300 3.297 3.227
2680 676,8 4,93 5,73 137,3 99 97 2/6 2 400-3-50 2680 4.070 1.960 1.300 3.364 3.794
2710 709,8 4,93 5,71 144,1 99 97 2/6 2 400-3-50 2710 4.070 1.960 1.300 3.407 3.837
TCHVBZ-TCHVIZ MODEL Nominal cooling capacity E.E.R. E.S.E.E.R. Absorbed power Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCHVBZ Weight TCHVIZ
mm mm mm kg kg
kW
1200 199,7 4,93 5,97 40,5 94 92 1/3 1 400-3-50 1200 3.460 1.460 1.000 1.333 1.588
1230 226,3 4,92 5,72 46,0 94 92 1/3 1 400-3-50 1230 3.460 1.460 1.000 1.359 1.614
1280 277,3 4,91 5,73 56,5 97 95 1/3 1 400-3-50 1280 3.440 1.460 1.000 1.695 1.950
1310 306,3 4,89 5,69 62,7 97 95 1/3 1 400-3-50 1310 3.440 1.460 1.000 1.713 1.968
1350 347,6 4,93 5,97 70,5 97 95 1/3 1 400-3-50 1350 3.450 1.640 1.000 1.865 2.120
1410 404,6 4,93 5,89 82,1 97 95 1/3 1 400-3-50 1410 3.450 1.640 1.000 2.354 2.609
1460 462,4 4,90 5,75 94,3 97 95 1/3 1 400-3-50 1460 3.450 1.640 1.000 2.393 2.648
1530 524,9 4,90 5,72 107,2 98 96 1/3 1 400-3-50 1530 3.450 1.740 1.000 2.642 2.897
1590 589,3 4,92 6,00 119,8 98 96 1/3 1 400-3-50 1590 3.450 1.740 1.000 2.687 2.942
Mini-Q Flow E Range (mod. 105-115) - Compact Flow E range (mod. 120-165) - Q-Flow E range (mod. 280-4260)
84
TCEE 1054260
Cooling capacity: 5.5-249 kW
Cooling only condenserless units to couple with CCAM remote condensers. Range with hermetic Scroll compressors and R407C refrigerant gas.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with incorporated thermal protection. Water side heat exchanger: stainless steel plate exchanger, complete with water ow dierential pressure switch. Control: microprocessor electronic control. Structure: in galvanised and painted sheet steel with polyester powder coating, complete with soundproofed compressor compartment (for mod. 105165). For mod. 2804260, the unit is also complete with: - High and low pressure gauges complete with capillaries.
Models
TCEEB: unit designed for cooling only. TCCEI: soundproofed unit designed for cooling only.
Modulating condensing control (only when coupled with CCAM). Refrigerant circuit high and low pressure gauges (only for 105165 models).
Versions
Antivibration rubber mountings. Remote keyboard with display. Serial interface for connection to BMS (proprietary protocol, Modbus RTU). Serial converter (RS485/RS232) in the case of centralised unit management. CCAM Remote condensers. Pump groups with buer tank PBHI (for 155-165 and 2804260 models).
B -Standard version (TCEEB). I -Soundproofed version with soundproofed compressor cover (TCCEI) for 2804260 models.
COOLING ONLY
INDOOR INSTALLATION
85
E.E.R. Absorbed power Sound power level Scroll/step compressor Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCEEB TCEEB-TCEEI MODEL Nominal cooling capacity E.E.R. Absorbed power Sound power level Sound power level Scroll/step compressor Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCEE mm mm mm kg kW dB(A) dB(A) no. no. V-ph-Hz kW mm mm mm kg kW dB(A) no. no. V-ph-Hz
3,30 2,0 51 1/1 1 230-1-50 105 750 869 615 154 280 74,2 3,47 25,4 71 69 2 1 400-3+N-50 280 1.214 1.703 873 645
3,58 4,1 57 1/1 1 400-3+N-50 115 750 869 615 172 2110 100,4 3,44 34,2 74 72 2 1 400-3+N-50 2110 1.214 1.703 873 790
3,52 6,0 60 1/1 1 400-3+N-50 120 750 869 615 211 2130 124,5 3,51 41,7 75 73 2 1 400-3+N-50 2130 1.214 1.703 873 808
3,58 8,4 64 1/1 1 400-3+N-50 125 750 869 615 224 4160 148,4 3,47 50,8 76 74 4 2 400-3+N-50 4160 2.407 1.079 873 906
3,68 10,8 67 1/1 1 400-3+N-50 135 750 869 615 247 4190 174,6 3,46 59,6 78 76 4 2 400-3+N-50 4190 2.407 1.709 873 1.015
3,74 12,7 68 1/1 1 400-3+N-50 140 750 869 615 270 4220 200,8 3,44 68,4 79 77 4 2 400-3+N-50 4220 2.407 1.709 873 1.121
3,40 17,1 71 1/1 1 400-3+N-50 155 987 869 636 490 4240 224,9 3,48 75,9 80 78 4 2 400-3+N-50 4240 2.407 1.709 873 1.140
3,49 20,8 72 1/1 1 165 987 869 636 505 4260 249,0 3,51 83,4 80 78 2 400-3+N-50 4260 2.407 1.709 873 1.157 4
In the following conditions: Chilled water: 12/7C - Dew point: 50C. Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. 10 m from the unit in free eld (Q = 2).
120 120 N 43 120 S 37 120 Q 32 2130 2130 N 61 2130 S 49 2130 Q 45 Circuits (1) (2) (1/2) (1) (2) (1/2) (1) (2) (1/2)
125 125 N 44 125 S 37 125 Q 35 4160(*) 280 N 280 N 59/59 280 S 280 S 52/52 280 Q 280 Q 46/46
135 135 N 46 135 S 39 135 Q 37 4190(*) 280 N 2110 N 59/61 280 S 2110 S 52/49 280 Q 2110 Q 46/43
140 140 N 46 140 S 46 140 Q 35 4220(*) 2110 N 2110 N 61/61 2110 S 2110 S 49/49 2110 Q 2110 Q 43/43
155 155 N 48 155 S 46 155 Q 40 4240(*) 2110 N 2130 N 61/61 2110 S 2130 S 49/49 2110 Q 2130 Q 43/45
165 165 N 49 165 S 47 165 Q 38 4260(*) 2130 N 2130 N 61/61 2130 S 2130 S 49/49 2130 Q 2130 Q 45/45
(*) Every model must be coupled with two condensers (one per circuit) in the CCAM range.
TERMINAL UNITS
2110
SYSTEM ACCESSORIES
CONDENSING UNITS
400-3+N-50
kW
5,5
11,6
17,2
24,3
31,8
37,1
50,2
62,2
TCEEB MODEL
105
115
120
125
135
140
155
165
Z-Flow E Range
86
TCEVZ 120031630
Cooling capacity: 171.9-1.424.8 kW
Ecient condenserless unit in R134a 33 sizes in standard and soundproofed versions Wide range of standard equipment
Cooling only condenserless units Range with semi-hermetic screw compressors and R134a refrigerant gas.
Construction features
Compressor: high energy eciency semi-hermetic screw compressor, with part-winding or star-delta limited start (depending on model) and complete with thermal protection, crankcase heater and compressor discharge shut-o valve. Electronic expansion valve: as standard on all models. Water side heat exchanger (evaporator): dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water ow dierential pressure switch and Victaulic connections. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - clock card for displaying date/time and machine time band management.
TCEVBZ 2630
Models
TCEVBZ: unit designed for cooling only. TCEVIZ: soundproofed unit designed for cooling only.
Power factor correction capacitors (cos > 0.94). Thermal overload switches Forced limit of the power consumption. Inlet compressor shut-o valves Linear capacity control compressors (50-100 % for each compressor). Evaporator antifreeze electric heater. Digital input for double set-point Compressor oil level sensor. Control of min/max power supply voltage. 4-20 mA analogue input for shifting set-point. Serial interface for connection with external BMS.
Versions
B -Standard version (TCEVBZ). I -Soundproofed version with soundproofed compressor cover (TCEVIZ).
Spring antivibration mountings. Antivibration rubber mountings. Remote keyboard with display. Rhoss sequencer for the integrated management of several water chillers.
C1FE C2FE
COOLING ONLY
INDOOR INSTALLATION
87
TCEVBZ-TCEVIZ MODEL Nominal cooling capacity E.E.R. Absorbed power Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCEVBZ Weight TCEVIZ TCEVBZ-TCEVIZ MODEL Nominal cooling capacity E.E.R. Absorbed power Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCEVBZ Weight TCEVIZ TCEVBZ-TCEVIZ MODEL Nominal cooling capacity E.E.R. Absorbed power Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCEVBZ Weight TCEVIZ TCEVBZ-TCEVIZ MODEL Nominal cooling capacity E.E.R. Absorbed power Sound power level Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCEVBZ Weight TCEVIZ
mm mm mm kg kg
In the following conditions: Chilled water: 12/7C - Dew point: 50C. Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614. Weight of fully accessorised unit when empty.
TERMINAL UNITS
31300 1.129,6 3,6 314,1 101 99 3/9 3 400-3-50 31300 4.940 1.620 2.000 5.555 6.155
31350 1.178,3 3,6 331,8 101 99 3/9 3 400-3-50 31350 4.940 1.620 2.000 5.570 6.170
31390 1.227,0 3,5 349,5 101 99 3/9 3 400-3-50 31390 4.940 1.620 2.000 5.585 6.185
31460 1.287,5 3,5 367,1 102 100 3/9 3 400-3-50 31460 4.940 1.620 2.000 5.600 6.200
31520 1.340,1 3,5 380,4 102 100 3/9 3 400-3-50 31520 4.940 1.620 2.000 5.678 6.278
31590 1.388,5 3,5 393,4 102 100 3/9 3 400-3-50 31590 4.940 1.620 2.000 5.710 6.310
31630 1.424,8 3,5 406,4 102 100 3/9 3 400-3-50 31630 4.940 1.620 2.000 5.790 6.390
SYSTEM ACCESSORIES
2750 647,8 3,4 192,1 99 97 2/6 2 400-3-50 2750 4.120 1.490 1.300 3.176 3.606
2790 681,6 3,3 207,6 99 97 2/6 2 400-3-50 2790 4.000 1.490 1.300 3.631 4.061
2880 753,9 3,3 226,5 99 97 2/6 2 400-3-50 2880 4.000 1.560 1.300 3.844 4.272
2930 801,4 3,3 244,4 99 97 2/6 2 400-3-50 2930 4.000 1.560 1.300 3.859 4.289
21030 896,1 3,5 257,9 99 97 2/6 2 400-3-50 21030 4.000 1.600 1.300 3.936 4.366
21110 959,4 3,5 271,0 99 97 2/6 2 400-3-50 21110 4.000 1.600 1.300 3.993 4.423
21180 1.027,8 3,6 285,5 99 97 2/6 2 400-3-50 21180 4.000 1.600 1.300 4.024 4.454
21260 1.101,5 3,7 299,4 99 97 2/6 2 400-3-50 21260 4.000 1.600 1.300 4.044 4.474
CONDENSING UNITS
2400 335,8 3,3 100,7 97 95 2/6 2 400-3-50 2400 3.870 1.490 1.300 1.797 2.227
2420 356,6 3,3 108,3 97 95 2/6 2 400-3-50 2420 3.870 1.490 1.300 1.811 2.241
2440 372,1 3,2 115,7 97 95 2/6 2 400-3-50 2440 3.870 1.490 1.300 1.819 2.249
2510 431,9 3,3 130,6 99 97 2/6 2 400-3-50 2510 4.070 1.610 1.300 2.311 2.741
2560 473,4 3,3 144,4 99 97 2/6 2 400-3-50 2560 4.070 1.610 1.300 2.629 3.059
2600 506,4 3,3 151,5 99 97 2/6 2 400-3-50 2600 4.070 1.610 1.300 2.637 3.067
2630 529,3 3,3 158,4 99 97 2/6 2 400-3-50 2630 4.070 1.610 1.300 2.638 3.068
2680 581,4 3,5 168,0 99 97 2/6 2 400-3-50 2680 4.070 1.610 1.300 2.698 3.128
2710 614,1 3,5 176,6 99 97 2/6 2 400-3-50 2710 4.070 1.610 1.300 2.733 3.163
kW
1200 171,9 3,4 50,5 94 92 1/3 1 400-3-50 1200 3.440 1.460 1.000 1.078 1.333
1230 190,8 3,3 58,1 94 92 1/3 1 400-3-50 1230 3.440 1.460 1.000 1.093 1.348
1280 238,1 3,3 72,2 97 95 1/3 1 400-3-50 1280 3.420 1.460 1.000 1.410 1.665
1310 260,4 3,3 79,0 97 95 1/3 1 400-3-50 1310 3.440 1.460 1.000 1.414 1.669
1350 300,6 3,4 88,1 97 95 1/3 1 400-3-50 1350 3.450 1.640 1.000 1.557 1.812
1410 346,2 3,3 104,0 97 95 1/3 1 400-3-50 1410 3.450 1.640 1.000 2.032 2.287
1460 399,7 3,3 122,2 97 95 1/3 1 400-3-50 1460 3.450 1.640 1.000 2.038 2.293
1530 446,4 3,3 135,3 98 96 1/3 1 400-3-50 1530 3.460 1.740 1.000 2.252 2.507
1590 508,9 3,4 149,7 98 96 1/3 1 400-3-50 1590 3.460 1.740 1.000 2.281 2.536
TCAEY 1182189
The applications for which this range is best suited include plastic & rubber processing, the food sector, the chemical and pharmaceutical industries and the electronic and automobile sectors. All models in the industrial range are equipped with the exclusive Adaptive Function Plus software, in addition to the system's advantages, and ensure that the temperature of the water delivered to the system will be stable also at a partial load. Thanks to its performance, the range is Eurovent and ECA certied (Enhanced Capital Allowances).
WINE line
89
kW
60
75
1300
RHOSS technology at the service of tradition for a greater result and guaranteed savings.
The transformation of the best grapes into excellent wines is no longer only entrusted to the know-how of enologists, technology has entered as an essential partner into the wine production cycle. The new WINE Range of chillers, studied especially by RHOSS, allows careful and delicate control of the temperatures, the humidity and heat exchanges, thus optimising and improving the production of musts and their fermentation, for the successive evolution and maturing of the wine.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
The nal success of all of these production processes is not only given by the attainment of the best wines but also by the reduction of energy consumption and the RHOSS technology applied to the chillers, the heatventilating units and the air handling units, allowing to save on production and management costs and to safeguard the environment.
TCAEY 1182189
Cooling capacity: 15.4161.9 kW
Ecient and exible industrial range in R410A 17 sizes for open circuits Wide range of standard equipment and accessories
Packaged air-cooled water chillers with axial fans. Range with hermetic Scroll compressors and R410A refrigerant.
Construction features
The units are made to operate on open circuits. Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater (mod. 1352189). 2 or 3 capacity steps with high eciency at partial loads (mod. 2532189). Water side heat exchanger: stainless steel plate exchanger, complete with closed cell polyurethane foam rubber insulation and water ow dierential pressure switch. Air side heat exchanger: nned coil with copper pipes and aluminium ns, complete with metal protection lters. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control with Adaptive Function Plus logic. Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - compressor and fan thermal overload switches.
The pumps are available in the low or high pressure versions. TANK&PUMP with inertial water buer tank, complete with antifreeze electric heater and single or double pump, including an automatic pump in standby (for mod. 253-2189 only), air bleed valves, water side pressure gauge, level indicator and top-up from above. Depending on the models, the pumps are available in low or high pressure versions. NON FERROUS option (mod. 2792189) with pump and/or water buer tank in stainless steel, copper and/or plastic pipes for demineralised water. Chilled water production, down to 10C (mod. 2792189). Crankcase heater compressor (mod. 118131). Soft - start device (mod. 2792189). Power factor correction capacitors (cos > 0.94) (mod. 2792189). Stainless steel metal lters for coil protection (mod. 2792189). Refrigerant circuit high and low pressure gauges (mod. 2792189). Pump antifreeze heaters (mod. 2792189). Digital input for double set-point 4-20 mA analogue input for shifting set-point.
Models
Without pump assembly and buer tank. PUMP (models 2792189) with single or double pump, including an automatic pump in standby, complete with air bleed valve, water side pressure gauge, level indicator and top-up from above.
Spring antivibration mountings. Remote keyboard with display. Clock card Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management.
C2CQ C3CQ
COOLING ONLY
OUTDOOR INSTALLATION
91
E.E.R. E.S.E.E.R. Absorbed power (*) Nominal cooling capacity E.E.R. Absorbed power (*) Sound pressure level Scroll/step compressor Circuits Water buffer tank content Available nominal head pressure of pump Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TCAEY MODEL Cooling capacity E.E.R. E.S.E.E.R. Absorbed power (*) Nominal cooling capacity E.E.R. Absorbed power (*) Sound pressure level Scroll/step compressor Circuits Water buffer tank content kW dB(A) no. no. l kW kW kW mm mm mm kg kW dB(A) no. no. l kPa kW kW
2,76 3,15 5,6 18,6 3,85 4,8 50,0 1/1 1 42 420 118 510 1.305 1.525 230 279 64,5 2,91 3,52 22,2 75,6 3,92 19,3 50,0 2/2 2 250 317 415 400-3+N-50 279 mm mm mm kg 3.150 1.520 1.210 1.070
2,67 3,11 6,5 21,0 3,73 5,6 50,0 1/1 1 42 390 121 510 1.305 1.525 240 299 79,7 2,99 3,64 36,7 93,5 4,03 23,3 51,0 2/2 2 250 273 375 400-3+N-50 299 3.150 1.520 1.210 1.080
2,76 3,44 8,2 27,7 3,88 7,1 50,5 1/1 1 51 336 128 510 1.505 1.525 290 2109 88,5 2,90 3,48 30,4 104,0 3,90 26,7 52,0 2/2 2 250 295 379 400-3+N-50 2109 3.150 1.520 1.210 1.200
2,62 3,09 9,3 29,3 3,69 7,9 50,5 1/1 1 51 335 131 510 1.505 1.525 300 2119 101,0 2,91 3,52 34,6 119,2 3,91 30,5 52,0 2/2 2 250 294 390 400-3+N-50 2119 3.150 1.520 1.210 1.320
2,50 2,89 11,8 34,7 3,30 10,5 55,0 1/1 1 55 271 135 610 1.740 1.825 390 2139 115,3 2,92 3,53 39,5 136,0 3,88 35,1 55,0 2/2 2 450 278 371 400-3+N-50 2139 3.250 2.000 1.520 1.550
2,56 2,85 13,3 40,5 3,38 11,7 52,1 1/1 1 80 520 140 1.710 1.570 1.070 470
2,55 3,78 17,4 53,2 3,52 15,0 54,0 2/3 1 150 480 253 2.315 1.570 1.070 645 2149 126,9 2,90 3,48 43,7 149,8 3,87 38,7 55,0 2/2 2 450 266 355
2,60 4,31 19,7 61,1 3,53 17,3 54,0 2/3 1 150 450 261 2.315 1.570 1.070 660 2169 145,0 2,90 3,49 50,0 170,8 3,86 44,3 56,0 2/2 2 450 316 443 400-3+N-50 2169 3.250 2.000 1.520 1.655
2,68 4,38 22,1 70,5 3,62 54,5 2/3 1 150 425 270 2.315 1.570 1.070 680 2189 161,9 2,90 3,48 55,9 190,9 3,86 49,4 56,0 2/2 2 450 284 412 400-3+N-50 2189 3.250 2.000 1.520 1.685
Available nominal head pressure of P1 pump kPa Available nominal head pressure of P2 pump kPa Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight V-ph-Hz
In the following conditions: Air: 35C - Water: 7/12C. Air: 27C - Water: 10/15C. At 10 m from the unit in free eld (Q = 2). The weight refers to the unit in its most complete form.
ESEER (European Seasonal EER) - Average European seasonal eciency. (*) Unit without pump.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
V-ph-Hz 400-3+N-50
19,4
Cooling capacity
kW
15,4
17,4
22,7
24,3
29,1
34,0
44,2
51,3
59,2
TCAEY MODEL
118
121
128
131
135
140
253
261
270
92
kW
60 2-pipe systems
75
950
Air conditioning and the production of hot water in a 2-pipe system is a typical application in residential units, hotels, hospitals, gyms and hospitality structures in general. EXPsystems in AUTOMATIC mode is used in the summer months for cooling and the production of hot water. EXPsystems in SELECT mode is used in between seasons or in winter for heating and the production of hot water on the basis of the priority assigned.
The evolved microprocessor control manages the two EXPsystems operating modes, AUTOMATIC and SELECT, catering to the demands of 2 or 4-pipe systems. - AUTOMATIC allows for the simultaneous or separate production of chilled and hot water, in a completely automatic fashion. - SELECT allows for the production of hot water and heating water on the basis of system demands and the priorities assigned by the user.
4-pipe systems
With increasing frequency, modern HVAC installations require simultaneous production of hot and cold water. This can occur more often because of: - the development of new types of thermal insulation for buildings; - increase in internal loads (CED, WEB, etc.); - lighting systems; - the presence of large windows; - the growing importance attributed to air quality, which requires the use of conditioning systems year-round. In these types of EXPsystems application, it can be used in AUTOMATIC mode throughout the year, catering to simultaneous or separate hot and chilled water demands in a completely automatic manner.
93
WATER
WATER
Summer season
cooling
Mid season
Winter season
heating
WATER
WATER
WATER
WATER
WATER
WATER
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
TXAEY 117133
Cooling capacity: 17.434 kW - Heating capacity: 17.939.1 kW
COP * up to 6.72
EXPsystems - Polyvalent ecological air-cooled system with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection and crankcase heater. Main and secondary heat exchanger: adequately insulated stainless steel plates, complete with antifreeze electric heater and water ow dierential pressure switch. Air side heat exchanger: featuring nned coil with copper pipes and aluminium ns, complete with protection grille. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function logic. Structure: in galvanised and painted sheet steel, complete with condensation drain pan.
Pump assembly for main circuit only complete with: inertial water buer tank, circulation pump, expansion tank with membrane, manual air bleed valve, automatic air bleed valve, safety valve, pressure gauge.
Silenced installation. Antifreeze electric heater on the buer tank. Unit base antifreeze electric heater for operation in heat pump mode at low outdoor air temperatures (mod.124). 117130). Single pump with increased head pressure (mod. 133). Single pump with increased head pressure + buer (mod. 133). Digital input for double set-point 4-20 mA analogue input for shifting set-point.
Models
Without pump assembly and water buer tank. Pump assembly for main circuit complete with: circulation pump, expansion tank with membrane, manual bleed valve and safety valve, pressure gauge.
Antivibration rubber mountings. Water lter. Remote keyboard with display. Clock card Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management.
OUTDOOR INSTALLATION
95
(AUTOMATIC 1) Recovery heating capacity (AUTOMATIC 2) Nominal heating capacity (SELECT 1-2 AUTOMATIC 3) Absorbed power (*) (AUTOMATIC 1) Absorbed power (*) (AUTOMATIC 2) Absorbed power (*) (SELECT 1-2 AUTOMATIC 3) C.O.P. (AUTOMATIC 2) Sound pressure level Silenced version sound pressure level Scroll/step compressor Circuits Water buffer tank content Available head pressure of standard pump Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TXAEY In the following conditions: Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B. - Water: 40/45C.
kW kW kW kW kW kW
23,6 30,4 26,1 9,4 7,4 8,9 6,72 52 49 1/1 1 131 400-3+N-50 124 1.522 1.280 600 280
28,6 37,2 34,4 11,7 9,8 11,1 6,13 53 50 1/1 1 110 400-3+N-50 130 1.822 1.510 695 370
34,0 44,2 39,1 13,3 11,5 13,3 6,25 54 51 1/1 1 80 400-3+N-50 133 1.660 1.570 1.000 470 134
5 m from the unit in free eld (Q = 2). Evaporator water: 12/7C. Recovery outlet water 45C - Nominal ow. (*) Unit without pump.
TERMINAL UNITS
Production of chilled or hot water for Summer or Winter air conditioning and/ or hot water for domestic use through EXPsystems units with air cooling (ex. residential environments).
SYSTEM ACCESSORIES
2-pipe systems
CONDENSING UNITS
TXAEY MODEL
117
124
130
133
TXAEY 245265
Cooling capacity: 42.661.9 kW - Heating capacity: 47.867.9 kW
COP * up to 7.48
EXPsystems - Polyvalent ecological air-cooled system with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection and crankcase heater. Main and secondary heat exchanger: adequately insulated stainless steel plates, complete with antifreeze electric heater and water ow dierential pressure switch. Air side heat exchanger: featuring nned coil with copper pipes and aluminium ns, complete with protection grille. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function logic. Structure: in galvanised and painted sheet steel.
bleed valves, safety valve and water side pressure gauge. The pumps are available in the low or high pressure versions. TANK&PUMP (for main circuit only) with water buer tank and single or double pump, including an automatic pump in standby, complete with expansion tank, air bleed valve, safety valve and water pressure gauge. The pumps are available in the low or high pressure versions. Silenced installation. Refrigerant circuit high and low pressure gauges. Antifreeze electric heater for buer tank and pumps. Digital input for double set-point 4-20mA analogue input for shifting set-point.
Models
PUMP (for main circuit only) with single or double pump, including an automatic pump in standby, complete with expansion tank, air
Antivibration rubber mountings. Water lter. Remote keyboard with display. Clock card Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management.
OUTDOOR INSTALLATION
97
(AUTOMATIC 1) Recovery heating capacity (AUTOMATIC 2) Nominal heating capacity (SELECT 1-2 AUTOMATIC 3) Absorbed power (*) (AUTOMATIC 1) Absorbed power (*) (AUTOMATIC 2) Absorbed power (*) (SELECT 1-2 AUTOMATIC 3) C.O.P. (AUTOMATIC 2) E.E.R. (EN 14511:2004) C.O.P. (EN 14511:2004) Sound pressure level Silenced version sound pressure level Scroll/step compressor Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight TXAEY
kW kW kW kW kW kW
50,6 65,0 55,8 18,5 15,5 18,6 7,30 3,34 3,94 56 53 2/1 1 400-3+N-50 250 2.260 1.570 1.000 775
58,2 71,8 62,2 21,6 17,1 20,5 7,32 3,39 3,93 57 54 2/1 1 400-3+N-50 260 2.260 1.570 1.000 795
61,9 81,1 67,9 24,0 19,0 23,3 7,48 3,44 3,97 57 54 2/1 400-3+N-50 265 2.260 1.570 1.000 825 1
In the following conditions: Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B. - Water: 40/45C. 5 m from the unit in free eld (Q = 2). Evaporator water: 12/7C. Recovery outlet water 45C - Nominal ow.
Energy indices calculated in compliance with that envisaged by EN 14511: 2004 Standard, in the conditions prescribed by the Finance Act, Italian market. (*) Unit without pump.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
TXAEY MODEL
245
250
260
265
TXAEY 2804320
Cooling capacity: 81334 kW - Heating capacity: 84353 kW
COP * up to 8.18
EXPsystems - Polyvalent ecological air-cooled system with axial fans. Range with hermetic Scroll compressors and R410A refrigerant gas.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection and crankcase heater. Main and secondary heat exchanger: crossed-ow stainless steel plate exchangers, complete with closed cell polyurethane foam rubber insulation and water ow dierential pressure switch. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: electric axial fans with EC motor with continuous adjustment of the rotation speed, equipped with internal thermal protection and complete with protection grilles. Control: microprocessor electronic control iDRHOSS compatible, with Adaptive Function Plus logic for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - compressor and fan thermal overload switches; - clock card for displaying date/time and machine time band management, - Electronic expansion valve.
T - High eciency/temperature version with fans with EC motor. S - Silenced version complete with soundproofed compressor technical compartment, lower fan speed with EC motor.
Versions
Models
PUMP (for main and secondary circuits) with single or double pump, including an automatic pump in standby, complete with expansion tank, safety valve and water side pressure gauge. The pumps are available in the low or high pressure versions. TANK&PUMP (for main circuit only) with built-in buer tank and single or double pump, complete with expansion tank, air bleed valves, safety valve and water pressure gauge. Power factor correction capacitors (cos > 0.91). Refrigerant circuit high and low pressure gauges. Metal lters or coil protection grilles. Copper/copper or copper/pre-painted aluminium coils. Digital input for double set-point 4-20 mA analogue input for shifting set-point. Evaporator antifreeze heater, buer tank, pumps and heat exchangers for heat recovery if present. Serial interface for connection with external BMS. Antivibration mountings.
OUTDOOR INSTALLATION
99
(AUTOMATIC 1) Recovery heating capacity (AUTOMATIC 2) Nominal heating capacity (SELECT 1-2 AUTOMATIC 3) Absorbed power (AUTOMATIC 1) Absorbed power (AUTOMATIC 2) Absorbed power (SELECT 1-2 AUTOMATIC 3) E.E.R. (AUTOMATIC 1) C.O.P. (AUTOMATIC 2) C.O.P. (SELECT 1-2 AUTOMATIC 3) Sound pressure level Sound power level TXASESY MODEL Nominal cooling capacity (AUTOMATIC 1) Recovery heating capacity (AUTOMATIC 2) Nominal heating capacity (SELECT 1-2 AUTOMATIC 3) Absorbed power (AUTOMATIC 1) Absorbed power (AUTOMATIC 2) Absorbed power (SELECT 1-2 AUTOMATIC 3) E.E.R. (AUTOMATIC 1) C.O.P. (SELECT 1-2 AUTOMATIC 3) Sound pressure level Sound power level MODEL Scroll/step compressor Circuits Electrical supply DIMENSIONS L - Width H - Height P - Depth
kW kW kW kW kW kW
108 140 111 34,8 32,1 33,5 3,1 7,76 3,31 52 84 2100 104 140 108 35,2 32,1 32,1 2,95 3,36 49 81 2100 2/2 2 400-3+N-50 2100 3.000 2.000 2.090
135 174 139 43,4 39,3 42,4 3,11 7,89 3,28 53 85 2130 130 174 136 43,9 39,3 40,7 2,96 3,34 50 82 2130 2/2 2 400-3+N-50 2130 3.700 2.000 2.090
163 215 171 56,1 51,6 54,5 2,91 7,36 3,14 54 86 4160 157 215 167 56,6 51,6 53,4 2,77 3,13 51 83 4160 4/4 2 400-3+N-50 4160 3.700 2.000 2.090
207 272 227 72,7 65,1 73,1 2,85 7,39 3,11 59 91 4200 200 272 221 73,7 65,1 70,4 2,71 3,14 54 86 4200 4/4 2 400-3+N-50 4200 4.800 2.030 2.090
264 346 281 92,1 81,4 91,5 2,87 7,53 3,07 61 93 4260 255 346 274 92,9 81,4 88,4 2,74 3,1 57 89 4260 4/4 2 400-3+N-50 4260 4.800 2.030 2.090
334 440 353 117,3 106,5 116,5 2,85 7,36 3,03 61 4320 317 440 344 118,8 106,5 111,8 2,67 3,08 57 89 4320 4/4 2 400-3+N-50 4320 4.800 2.030 2.090
dB(A) dB(A)
52 84 280
kW kW kW kW kW kW
In the following conditions: Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B. Water: 40/45C. 10 m from the unit in free eld (Q = 2). Evaporator water: 12/7C. Recovery outlet water 45C Nominal ow. Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
93
TXAETY MODEL
280
2100
2130
4160
4200
4260
4320
TXAVZ 24202700
Cooling capacity: 408698 kW - Heating capacity: 413707 kW
COP * up to 8.33
TXAVSZ 2700
TXAVSZ 2550
EXPsystems - Polyvalent ecological air-cooled system with axial fans. Range with semi-hermetic screw compressors and R134a refrigerant gas.
Construction features
Compressor: high energy eciency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater, refrigerant gas intake and delivery piping shut-o valve and compressor oil level sensor. Electronic expansion valve: as standard on all models. Main and secondary heat exchanger: dry expansion shell and tube exchanger with counter-current heat exchange, complete with closed cell polyurethane rubber foam insulation, water ow dierential pressure switch and Victaulic connections. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: electric axial fans with external rotor, equipped with internal thermal protection, protection grilles and proportional electronic device for continuous fan rotation speed regulation. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating The unit is also complete with: - display of refrigerant circuit high/low pressure; - clock card for displaying date/time and machine time band management.
Versions
B - Standard version (TXAVBZ). S - Silenced version with lower fan speed and soundproofed compressor cover (TXAVSZ). I -Soundproofed version with soundproofed compressor cover (TXAVIZ).
Models
TXAVBZ: standard EXPsystems unit. TXAVSZ: silenced EXPsystems unit. TXAVIZ: soundproofed EXPsystems unit.
Power factor correction capacitors (cos > 0.94). Compressor and fan thermal overload switches. Forced limit of the power consumption. Protection coil grilles. Bottom compartment protection grilles. Main and secondary heat exchanger antifreeze heater. Digital input for double set-point Low and high pressure gauges for each refrigerant circuit. Control of min/max power supply voltage. 4-20 mA analogue input for shifting set-point. Copper/pre-painted aluminium or copper/copper coils. Serial interface for connection with external BMS. Spring antivibration mountings.
OUTDOOR INSTALLATION
101
(AUTOMATIC 1) Recovery heating capacity (AUTOMATIC 2) Nominal heating capacity (SELECT 1-2 AUTOMATIC 3) Absorbed power (AUTOMATIC 1) Absorbed power (AUTOMATIC 2) Absorbed power (SELECT 1-2 AUTOMATIC 3) E.E.R. (AUTOMATIC 1) C.O.P. (AUTOMATIC 2) C.O.P. (SELECT 1-2 AUTOMATIC 3) Sound pressure level Sound power level TXAVSZ MODEL Nominal cooling capacity (AUTOMATIC 1) Recovery heating capacity (AUTOMATIC 2) Nominal heating capacity (SELECT 1-2 AUTOMATIC 3) Absorbed power (AUTOMATIC 1) Absorbed power (AUTOMATIC 2) Absorbed power (SELECT 1-2 AUTOMATIC 3) E.E.R. (AUTOMATIC 1) C.O.P. (SELECT 1-2 AUTOMATIC 3) Sound pressure level Sound power level MODEL Screw compressor/steps Circuits Electrical supply L - Width H - Height P - Depth Weight TXAVBZ
kW kW kW kW kW kW
482 622 490 165,3 142,0 158,8 2,92 7,79 3,09 65 98 2480 463 622 470 164,5 142,0 158,0 2,81 2,97 59 92 2480 2/6 2 400-3-50 2480 6.130 2.430 2.260 6.300
555 709 568 179,2 155,8 177,7 3,10 8,13 3,20 65 98 2550 533 709 545 178,3 155,8 176,8 2,99 3,08 59 92 2550 2/6 2 400-3-50 2550 6.130 2.430 2.260 6.360
617 786 625 198,4 170,7 194,8 3,11 8,24 3,21 66 99 2610 592 786 600 197,4 170,7 193,8 3,00 3,10 60 93 2610 2/6 2 400-3-50 2610 6.980 2.430 2.260 7.460
698 888 707 224,1 190,9 220,8 3,11 8,33 3,20 67 2700 670 888 679 223,0 190,9 219,7 3,00 3,09 61 93 2700 2/6 2 400-3-50 2700 7.980 2.430 8.380 2.260
dB(A) dB(A)
65 98 2420
kW kW kW kW kW kW
In the following conditions: Air: 35C - Water: 12/7C. Air: 7C D.B. - 6C W.B. - Water: 40/45C. 10 m from the unit in free eld (Q = 2). Evaporator water: 12/7C. Recovery outlet water 45C Nominal ow. Empty weight Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
99
TXAVBZ MODEL
2420
2480
2550
2610
2700
TXHEY 105112
EXPsystems - Polyvalent ecological watercooled system. Range with hermetic Scroll compressors and R410A refrigerant gas.
Construction features
Compressor: hermetic, rotary scroll compressor, complete with thermal protection. Primary side heat exchanger (user), secondary side exchanger (recovery) and disposal unit: adequately insulated stainless steel plates, complete with antifreeze electric heater and water ow dierential pressure switch. Control: microprocessor electronic control, iDRHOSS compatible, with Adaptive Function logic. Condensation control: pressure switch valve and bypass solenoid valve. Structure: in galvanised and painted sheet steel with polyester powder coating, complete with soundproofed compressor compartment.
Well/tower side (disposal unit): drain valve and bleed valve. Internal cock for primary side (use) system supply from external network (disposal unit side: well or tower). Secondary side (recovery): pump assembly complete with electric circulation pump, membrane expansion tank, safety valve, water drain valve, manual air bleed valve, pressure gauge.
Digital input for double set-point 4-20mA analogue input for shifting set-point.
Models
PUMP unit
Primary side (user): pump assembly complete with electric circulation pump, membrane expansion tank, safety valve, water drain valve, manual air bleed valve, pressure gauge.
Water buer tank Buer connection pipes Water lter. Antivibration rubber mountings. Antifreeze electric heater on the buer tank. Remote keyboard with display. Clock card Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU, LonWorks). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. GSM 900/1800 modem kit for remote unit management. RHOSS supervision software for unit monitoring and remote management.
INDOOR INSTALLATION
103
(AUTOMATIC 1) Recovery heating capacity (AUTOMATIC 2) Nominal heating capacity (SELECT 1-2 AUTOMATIC 3) Total absorbed power (*) (AUTOMATIC 1) Total absorbed power (*) (AUTOMATIC 2) Total absorbed power (*) (SELECT 1-2 AUTOMATIC 3) C.O.P. (AUTOMATIC 2) Sound pressure level Scroll/step compressor Circuits Water buffer tank content Nominal available head pressure at pump on main exchanger Nominal available head pressure on secondary recovery exchanger Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height TXHEY P H - Height TXHEY P + KA P - Depth Weight TXHEY Weight KA
kW kW kW kW kW kW
6,8 8,7 8,2 2,12 2,83 2,88 5,14 51,1 1 1 20 54,7 42,4 230-1-50 400-3+N-50 107 585 535 855 520 118 38 (*) Unit without pumps. KA = Water buer tank. KTC = Connection pipes.
9,3 11,3 10,8 2,74 3,57 3,54 5,42 51,3 1 1 30 82,2 72,1 230-1-50 400-3+N-50 109 660 535 855 560 122 43
12,0 14,5 13,9 3,60 4,75 4,38 5,67 53,1 1 1 30 78,2 66,7 230-1-50 400-3+N-50 112 660 535 855 560 130 43
mm mm mm kg kg
2-pipe systems
Production of chilled or hot water for Summer or Winter air conditioning and/or hot water for domestic use through EXPsystems units with water cooling (ex. residential environments).
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Condenser water: 30/35C - Chilled water: 12/7C. Chilled water: 12/7C - Recovery unit water: 40/45C. Evaporator water: 10C - Water ow rate as in summer operation. Hot water: 40/45C. 1 m from the unit in free eld (Q = 2).
mm
585
TXHEY P MODEL
105
107
109
112
TXHVZ 24102740
Cooling capacity: 434782 kW - Heating capacity: 482878 kW
GREEN LINE
TXHVIZ 2740
EXPsystems - Polyvalent ecological watercooled system. Range with semi-hermetic screw compressors and R134a refrigerant gas.
Construction features
Compressor: high energy eciency semi-hermetic screw compressor, with star-delta limited start and complete with thermal protection, crankcase heater, refrigerant gas intake and delivery piping shut-o valve and compressor oil level sensor. Electronic expansion valve: as standard on all models. Primary side heat exchanger (user), secondary side exchanger (recovery) and disposal unit: dry expansion shell and tube exchangers, complete with closed cell polyurethane rubber foam insulation, water ow dierential pressure switch and Victaulic connections. Control: electronic microprocessor control prepared for connection with the main BMS on the market (MODBUS RTU, LON). Structure: in galvanised and painted sheet steel, with polyester powder coating. The unit is also complete with: - low and high pressure gauges for each refrigerant circuit. - clock card for displaying date/time and machine time band management.
Versions
B - Standard version (TXHVBZ). I - Soundproofed version with soundproofed compressor cover (TXHVIZ).
Models
Power factor correction capacitors (cos > 0.94). Compressor thermal overload switches. Forced limit of the power consumption. Heat exchanger antifreeze heater. Digital input for double set-point Display of refrigerant circuit high/low pressure. Control of min/max power supply voltage. 4-20 mA analogue input for shifting set-point. Serial interface for connection with external BMS.
INDOOR INSTALLATION
105
(AUTOMATIC 1) Nominal cooling capacity (AUTOMATIC 1) Recovery heating capacity (AUTOMATIC 2) Nominal heating capacity (SELECT 1-2 AUTOMATIC 3) Total absorbed power (AUTOMATIC 1) Total absorbed power (AUTOMATIC 1) Total absorbed power (AUTOMATIC 2) Total absorbed power (SELECT 1-2 AUTOMATIC 3) E.E.R. (AUTOMATIC 1) E.E.R. (AUTOMATIC 1) C.O.P. (SELECT 1-2 AUTOMATIC 3) TXHVBZ MODEL Sound power level Screw compressor/steps Circuits Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth
kW kW kW kW kW kW kW kW
434 408 458 482 78,8 86,6 103,6 105,6 5,51 4,71 4,56 2410
476 450 513 539 87,6 96,4 116,8 119,0 5,43 4,67 4,53 2450 97 2/6 2 400-3-50 2450 4.420 2.030 1.620
531 501 559 589 92,8 101,8 121,4 123,6 5,72 4,92 4,77 2500 98 2/6 2 400-3-50 2500 4.420 2.030 1.620
626 592 662 694 107,2 119,6 142,2 144,6 5,84 4,95 4,80 2590 99 2/6 2 400-3-50 2590 4.420 2.030 1.620
698 660 735 773 121,8 132,4 157,4 160,8 5,73 4,98 4,81 2660 99 2/6 2 400-3-50 2660 4.420 2.030 1.620
782 738 833 878 138,2 151,0 180,8 184,4 5,66 4,89 4,76 2740 99 2/6 2 400-3-50 2740 4.420 2.030 1.620
In the following conditions: Chilled water (user): 12/7C - Condenser water (disposal unit-source): 14/30C. Chilled water (user): 12/7C - Condenser water: 30/35C. Chilled water (user): 12/7C - Condenser water (regenerator)r: 40/45C. Evaporator water (source): 14C - Water ow rate as in summer operation (). Hot water (user): 40/45C. Total sound power level in dB(A) on the basis of measurements taken in accordance with UNI EN-ISO 9614.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
2410
2450
2500
2590
2660
2740
106
MCAE-MHAE 108127
Cooling capacity: 7.626.3 kW - Heating capacity: 929.9 kW
Air-cooled condensing units and reversible condensing units, with axial fans. Range with hermetic compressors and R407C refrigerant gas.
Construction features
Compressor: hermetic scroll complete with thermal protection (mod. 108127). Air side heat exchanger: featuring nned coil with copper pipes and aluminium ns, complete with protection grille. Fan: electric axial fan with external rotor, equipped with internal thermal protection and complete with protection grille. Control: microprocessor electronic control. Structure: galvanised and painted sheet steel with epoxy nish, complete with rubber antivibration mountings and cataphoresistreated sheet steel base (mod. 108110), in peraluman with galvanised sheet steel base and soundproofed compressor compartment (mod. 115127).
Models
MCAE: unit designed for cooling only. MHAE: heat pump unit.
Wall-support shelves (mod.105110). 108110). Connection cover (mod. 108110). Rubber antivibration mountings (mod. 115127). -10C condensation control. RS 485 serial interface (mod. 115127). RS 232 hardware key (mod. 115127).
COOLING ONLY
HEAT PUMP
OUTDOOR INSTALLATION
107
Absorbed power MHAE MODEL Nominal heating capacity Nominal cooling capacity Absorbed power MCAE-MHAE MODEL Sound pressure level Mains supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight MCAE Weight MHAE
kW kW kW kW dB(A) V-ph-Hz
3,00 108 9,0 7,6 2,81 108 55 230-1-50 400-3+N-50 108 830 900 300 84 88
3,40 110 10,4 8,5 3,20 110 54 400-3+N-50 110 830 900 300 85 90
4,91 115 15,8 14,7 5,12 115 49 400-3+N-50 115 1.326 1.230 527 180 200
5,65 118 19,9 17,6 5,63 118 50 400-3+N-50 118 1.326 1.230 527 200 210
7,41 122 24,5 21,8 7,23 122 51 400-3+N-50 122 1.716 1.230 615 260 280
8,92 127 29,9 26,3 8,40 52 400-3+N-50 127 1.716 615 290 300 1.230
mm mm mm kg kg
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Air: 35C - Sucked saturated gas: 7C. Air: 6C W.B. - Condensation: 45C (mod. 105-110); 50C (mod. 115127). 5 m from the unit in free eld (Q = 2).
127
kW
7,6
8,5
14,7
17,6
21,8
26,3
MCAE MODEL
108
110
115
118
122
127
108
MCAE 1312181
Cooling capacity: 30.5-181.1 kW
Air-cooled condensing units with axial fans. Range with hermetic compressors and R407C refrigerant gas.
Construction features
Compressor: hermetic, rotary Scroll compressor, complete with thermal protection and crankcase heater. Air side heat exchanger: nned coil exchanger with copper pipes and aluminium ns. Fan: electric axial fans with external rotor, equipped with internal thermal protection, proportional electronic device for continuous fan rotation speed regulation and protection grilles. Control: microprocessor electronic control. Structure: in galvanised and painted sheet steel, with polyurethane powder coating.
Models
Compressor compartment soundproong. Coil protection metal lters. Refrigerant circuit high and low pressure gauges. Liquid receiver. Liquid and gas line shut-o valves.
COOLING ONLY
OUTDOOR INSTALLATION
109
Absorbed power Scroll/step compressor Circuits Sound pressure level Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight MCAE MODEL Nominal cooling capacity Absorbed power Scroll/step compressor Circuits Sound pressure level Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight In the following conditions: Air: 35C - Sucked saturated gas: 5C. 10 m from the unit in free eld (Q = 2).
8,6 1/1 1 52,5 400-3+N-50 131 1.870 1.406 850 320 276 291 90,1 25,8 2/2 1 53,5 400-3+N-50 291 2.608 1.759 1.105 790
10,8 1/1 1 52,5 400-3+N-50 139 1.870 1.406 850 331 2103 103,0 30,0 2/2 1 55,5 400-3+N-50 2103 3.608 1.759 1.105 1.040
12,9 1/1 1 52,5 400-3+N-50 145 1.870 1.406 850 342 2121 120,5 34,1 2/2 1 56,0 400-3+N-50 2121 3.608 1.759 1.105 1.120
12,5 2/2 1 52,5 400-3+N-50 243 1.870 1.406 850 545 2136 135,5 38,2 2/2 1 56,4 400-3+N-50 2136 3.608 1.759 1.105 1.170
15,1 2/2 1 52,5 400-3+N-50 252 1.870 1.406 850 560 2146 140,4 40,3 2/2 1 56,6 400-3+N-50 2146 3.608 1.759 1.105 1.200
17,1 2/2 1 52,5 400-3+N-50 261 2.608 1.759 1.105 690 2163 163,2 46,4 2/2 1 57,0 400-3+N-50 2163 3.608 2.179 1.105 1.300
19,3 2/2 1 52,5 400-3+N-50 2.608 1.759 1.105 705 2181 181,1 50,5 2/2 1 57,5 400-3+N-50 3.608 2.179 1.105 1.480 2181
75,5 21,5 2/2 1 53,5 400-3+N-50 276 2.608 1.759 1.105 740
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
268
kW
30,5
37,0
45,2
43,0
52,2
61,1
67,6
MCAE MODEL
131
139
145
243
252
261
268
Remote condensers
110
CCAM 1052130
Remote air condensers with axial fans for direct expansion units operating with R407C refrigerant gas.
Construction features
Heat exchanger: featuring high eciency nned coil with copper pipes joined to aluminium ns by mechanical expansion. The unit undergoes pressure and seal tests, guaranteeing a maximum working pressure of 31 bar. The refrigerant circuits connections need brazing. The units are supplied pressurised with nitrogen. Fans: axial fans with external rotor; rotating body of motor and fan blades with aerodynamic conguration that guarantees quiet operation and high performance. The electric fans are also speed-adjustable (by means of the TCEE 1052130 condenserless unit PSC accessory) and are protected against overloads by thermal overload switches. Structure: in galvanised and painted sheet steel with epoxy powder coating. The remote condensers come equipped with a support bracket kit for vertical/horizontal air ow. The support brackets are made from stainless steel for the condensers with fans measuring from 400500 mm, and in galvanised and painted steel for the condensers with fans measuring from 6301,000 mm.
The brackets are of an optimum length for uniform air suction into the coil. The motors are wired in compliance with VDE 0530/12.84. IP54 protection, in compliance with DIN 40050. Electrical panel compliant with IEC standards. Sealed box with IP55 protection, complete with: - Main isolating switch complete with door interlocking isolator; - Power contactors; - Thermal overload switch; - Indicator lights and remote-controlled alarms. - The electric panel for condensers with fans measuring from 400 to 500 mm is not installed upon delivery. The client is responsible for its installation.
Versions
The CCAM 1052130 range remote condensers are available in 3 construction options that meet the dierent system requirements concerning ambient noise emission: - Version N Normal (mod. 105-115 excluded); - Version S Silenced; - Version Q Supersilenced.
OUTDOOR INSTALLATION
111
Nominal heating capacity Sound pressure level Refrigerant circuits Fans Fan nominal air flow Rotation speed Absorbed power Electrical supply CCAM MODEL VERSION S "Silenced" Sound pressure level Refrigerant circuits Fans Fan nominal air flow Rotation speed Absorbed power Electrical supply CCAM MODEL VERSION Q Supersilenced Nominal heating capacity Sound pressure level Refrigerant circuits Fans Fan nominal air flow Rotation speed Absorbed power Electrical supply Nominal heating capacity
V-ph-Hz 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 105S kW dB(A) no. no. m /h rpm kW V-ph-Hz 11,7 36 1 2 4.994 940 0,32 230/1/50 105Q kW dB(A) no. no. m /h rpm kW V-ph-Hz 12,0 29 1 1 3.598 665 0,13 230/1/50 115S 15,1 34 1 1 4.964 930 0,27 400/3+N/50 115Q 15,3 32 1 1 4.218 800 0,19 400/3+N/50 120S 23,4 37 1 2 10.471 930 0,54 400/3+N/50 120Q 24,1 32 1 2 7.236 680 0,30 400/3+N/50 125S 33,2 37 1 2 9.449 930 0,54 135S 45,4 39 1 3 14.892 930 0,81 140S 54,8 46 1 3 19.653 1.180 1,65 400/3+N/50 140Q 52,8 35 1 4 13.728 680 0,60 400/3+N/50 155S 63,4 46 1 3 18.330 1.180 1,65 400/3+N/50 155Q 65,7 40 1 4 18.898 930 1,08 400/3+N/50 165S 77,5 47 1 4 24.901 1.180 2,20 400/3+N/50 165Q 81,8 38 1 2 19.610 440 0,74 400/3+N/50 280S 96,0 52 1 1 29.530 890 3,60 400/3+N/50 280Q 104,0 46 1 4 31.400 690 1,92 400/3+N/50 2110S 123,3 49 1 2 31.940 660 2,50 2130S 172,3 49 1 3 50.100 680 3,15
400/3+N/50 400/3+N/50
400/3+N/50 400/3+N/50
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
In the following conditions: Outdoor temperature: 35C D.B. - 24C W.B. - Dew point: 50C. - Subcooling 3K Superheating 25K. - Maximum speed. 10 m from the unit in free eld (Q = 2).
400/3+N/50 400/3+N/50
400/3+N/50 400/3+N/50
1.310
VERSION N Normal
CCAM MODEL
120N
125N
135N
140N
155N
165N
280N
2110N
2130N
Cooling towers
112
Wide range of models up to 2,800 kW Silenced version with considerable noise reduction Compact easy to install units
Cooling towers for water chillers with water condensation. Axial fans
Construction features
Distribution system: polyvinyl chloride pipes and plastic spray nozzles. Heat exchange package: panel exchanger with plastic cellular structure with large slots. Drop separator: plastic. Fan: axial fan directly coupled with protection grille. Condensation drain pan: in polyester resin strengthened with breglass complete with spray protection ns, drain connections, oat re-integration and overow. Structure: in polyester resin strengthened with breglass and loadbearing with an inspection pothole for models of the CEHV range; with hot-galvanised steel sections and with lateral damping using 22 mm sandwich panels in polyester resin strengthened with breglass and a manhole for models of the CEHP-CEHPS range.
Models
CEHV 46639 Cooling towers with load-bearing polyester resin structure strengthened with breglass. CEHP 7442791 Cooling towers with hot- galvanised steel sections and with lateral damping using 22 mm sandwich panels in polyester resin strengthened with breglass. CEHPS 7442791 Silenced cooling towers with hot- galvanised steel sections and with lateral damping using 22 mm sandwich panels in polyester resin strengthened with breglass.
Electrical anti-freeze heater on condensation drain pan complete with minimum level switch.
Dismantable side wall. Electrical anti-freeze heater on condensation drain pan complete with minimum level switch.
OUTDOOR INSTALLATION
113
Installed fan electrical power Sound power level Sound pressure level Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Empty weight Operating weight CEHP MODEL Nominal heating capacity consumption Installed fan electrical power Sound power level Sound pressure level Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Empty weight Operating weight CEHPS MODEL Nominal heating capacity consumption Installed fan electrical power Sound power level Sound pressure level Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Empty weight Operating weight
0,55 74 46 46
0,75 75 47 87 1000 2595 1000 85 215 826 5,5 90 62 826 2025 3650 2365 920 2520 826 5,5 79 51 826 2025 3905 2365 920 2520 878 5,5 92 64 878 2365 3650 2365 965 2865 878 7,5 80 52 878 2365 3905 2365 965 2865
0,75 75 47 105 1000 2595 1000 95 285 971 7,5 92 64 971 2365 3650 2365 1000 2900 971 7,5 80 52 971 2365 3905 2365 1000 2900
220/380-3-50 AIR cooled CENTRIFUGAL fans WATER cooled CONDENSERLESS UNITS 800 2110 800 75 180 744 2300
mm mm mm kg kg
kW 744,2 kW dB(A) dB(A) V-ph-Hz 744 mm mm mm kg kg 2025 3650 2365 885 2485 744 kW 744,2 kW dB(A) dB(A) V-ph-Hz 744 mm mm mm kg kg 2025 3905 2365 885 2485 5,5 79 51 4 90 62
1186 1255,8 1395,3 1488,4 1651,2 1755,8 1947,7 2139,5 2366,3 2511,6 2790,7 11 94 66 11 95 67 11 95 67 2X4 2X5.5 2X5.5 2X7.5 2X7.5 93 65 93 65 95 67 1756 4750 3650 2365 1790 5430 1756 95 67 97 69 2X11 97 69 2X11 2X11 98 70 98 70
380/660-3-50 1070 1186 1256 1395 1488 1651 2875 3650 2365 1115 3815 2875 3650 2365 1165 3865 3370 3650 2365 1220 4320 3370 3650 2365 1270 4370 4080 3650 2365 1630 4680 4080 3650 2365 1700 4750 1948 2139 2366 4750 5770 3650 3950 2365 2365 1860 2125 5500 7325 5770 3950 2365 2225 7425 2512 2791 3950 3950 2365 2365 2375 2475 8375 8475 2512 2791 2X11 2X11 86 58 86 58 6770 6770
1186 1255,8 1395,3 1488,4 1651,2 1755,8 1947,7 2139,5 2366,3 2511,6 2790,7 11 82 54 11 83 55 11 2X5.5 2X5.5 2X7.5 2X7.5 2X11 83 55 82 54 82 54 83 55 1756 4750 3905 2365 1790 5430 83 55 85 57 2X11 85 57
380/660-3-50 1070 1186 1256 1395 1488 1651 2875 3905 2365 1115 3815 2875 3905 2365 1165 3865 3370 3905 2365 1220 4320 3370 3905 2365 1270 4370 4080 3905 2365 1630 4680 4080 3905 2365 1700 4750 1948 2139 2366 4750 5770 3905 4205 2365 2365 1860 2125 5500 7325 5770 4205 2365 2225 7425 2512 2791 6770 6770 4205 4205 2365 2365 2375 2475 8375 8475
TERMINAL UNITS
SYSTEM ACCESSORIES
In the following conditions: Air: 24C W.B. - Water: 35/30 C. 10 m from the unit in free eld (Q = 2).
CONDENSING UNITS
2512 2791
kW
46,5
87,2
104,7
139,5
168,6
203,5
238,4
337,2
395,3
476,7
505,8
598,8
639,5
CEHV MODEL
46
87
105
139
169
203
238
337
395
477
506
599
639
Pumping groups
114
AS 03002500
Water buer tank from 300 to 2,500 l Multiple combinations for pump user-side Connection to the system on the water outlet, on the water return
Pump groups with buer tank.
Construction features
Water buer tank: in carbon steel with a capacity of 300, 500, 750, 1,000, 1,500, or 2,500 litres. Water circuit components: single or double centrifugal pump, inlet and outlet shut-o ball valve of each pump, automatic reintegration tap, manual re-integration tap, safety valve, automatic air bleed valve, tank water drain tap, expansion tank with membrane, no-return valve (with double pump only), pressure gauge. The water circuit is insulated with closed cell expanded polyurethane of adequate thickness. Structure: Load-bearing structure made of aluminium sheet metal panelling and base in galvanised and painted steel. Control: electromechanical.
Models
AS 0300 PU or DPU 15: pump assembly equipped with single pump on user side (PU) or double pump on user side (DPU). AS 0500 PU or DPU 15: pump assembly equipped with single pump on user side (PU) or double pump on user side (DPU). AS 0750 PU or DPU 610: pump assembly equipped with single pump on user side (PU) or double pump on user side (DPU). AS 1000 PU or DPU 610: pump assembly equipped with single pump on user side (PU) or double pump on user side (DPU). AS 1500 PU or DPU 614: pump assembly equipped with single pump on user side (PU) or double pump on user side (DPU). AS 2500 PU or DPU 614: pump assembly equipped with single pump on user side (PU) or double pump on user side (DPU).
Versions
115
Pump model Expansion tank capacity Expansion tank calibration Safety valve calibration Maximum working pressure Electric heater (optional) Hydraulic connections (female) Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight (*) (*) Weight of fully accessorised unit when empty. mm mm mm kg l bar bar bar W (Gas) V-pH-Hz 25 1,5 3,0 3,0 1.300 21/2 400-3-50 AS 0300 1.504 1.265 1.120 231
1-2-3-4-5 25 1,5 3,0 3,0 1.300 21/2 400-3-50 AS 0500 1.504 1.265 1.120 253 25 1,5 3,0 3,0 1.300 3 400-3-50 AS 0750 2.044 1.510 1.200 501
6-7-8-9-10 25 1,5 3,0 3,0 1.300 3 400-3-50 AS 1000 2.044 1.510 1.200 528
6-7-8-9-10-11-12-13-14 2X25 1,5 3,0 3,0 1,300X2 4 400-3-50 AS 1500 2.260 1.782 1.900 878 X25 1,5 3,0 3,0 4 400-3-50 AS 2500 2.260 1.782 930 1.900
TANK Model 1 2 3 4 5 6 7 8 9 10 11 12 13 14
PUMP litres 300 or 500 300 or 500 300 or 500 300 or 500 300 or 500 750 or 1,000 750 or 1,000 750 or 1,000 750 or 1,000 750 or 1,000 1,500 or 2,500 1,500 or 2,500 1,500 or 2,500 1,500 or 2,500
Available head pressure (*) m.c.a. 15,5 19,0 12,4 18,2 20,4 17,0 27,4 17,9 20,5 29,0 36,0 29,0 34,0 43,1
Available head pressure (*) m.c.a. 13,5 17,0 10,8 16,6 18,8 16,0 25,2 15,0 17,5 26,0 33,0 27,0 32,5 41,0
Available head pressure (*) m.c.a. 11,1 14,7 7,5 13,3 15,6 20,5 12,0 15,0 23,0 30,0 24,0 37,0 30,0 14,1
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
1,300X2
Tank capacity
300
500
750
1.000
1.500
2.500
MODEL
AS 0300
AS 0500
AS 0750
AS 1000
AS 1500
AS 2500
Pumping groups
116
PBHI 0200-0400
Cooling capacity: 50.2249 kW
Primary and secondary circuit FREE-COOLING version Pump option with integrated inverter
Pump groups with buer tank for combination with TCEE units with hermetic Scroll compressors (models 155-4260).
Construction features
Water buer tank: in carbon-plated and pre-painted steel sheet, with a 200 or 425 litre capacity. Water circuit components: primary circuit complete with single pump, secondary circuit complete with single standard head pressure pump, buer tank, expansion tank, safety valve, shut-o valves, tank water charge/drain taps and automatic and manual air bleed valves. Heat exchanger: brazed plate exchanger complete with adjustable ow switch (Free-Cooling version only). Control: electromechanical. Structure: load-bearing structure in galvanised and painted sheet steel with polyester powder coating. The panels are removable in order to allow for easy access to the internal components.
Models
PBHI 0200 B: standard pump assembly for combination with TCEE 155-165 units. PBHI 0400 B: standard pump assembly for combination with TCEE 280-4260 units. PBHI 0200 F: Free-Cooling version pump assembly for combination with TCEE 155-165 units. PBHI 0400 F: Free-Cooling version pump assembly for combination with TCEE 280-4260 units.
Single secondary circuit pump with increased head pressure. Double secondary circuit pump with standard or increased head pressure, including one in standby with automatic activation. Single centrifugal pump with built-in inverter, able to maintain a constant pressure despite variations in system demands. Antifreeze heater 300 W (230V) with activator.
Versions
B - Standard version: with single primary and secondary circuit pump (standard head pressure). F - Free-Cooling version: tted with indirect Free-Cooling heat exchanger.
Antivibration rubber mountings. Flexible tubes for connection to the water chiller/heat pump.
117
Expansion tank capacity Expansion tank calibration Safety valve calibration Maximum working pressure Electric heater (optional) Hydraulic connection (female) Sound power level Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth
8 150 600 600 300 2SDSq F 71 400-3+N-50 0200 1.340 1.206 861
USER UTENZA
R
VE SA M S
VS
SECONDARY CIRCUIT PUMP ACCESSORIES: PBHI water circuit with double pump on user side
FREE-COOLING ONLY
FREECOOLING
USER
UTENZA
CIRCUITO SECONDARIO
SECONDARY CIRCUIT
VR SA R VR DPU
VE M S
VS
MACCHINA
R1
FREE-COOLING ONLY
VSA VSM R1 RA
UTENZA USER CIRCUITO SECONDARIO SECONDARY CIRCUIT
PZ R P R FL PZ PHF
PZ PZ
25 Hz
VE SA M S
VS
MACCHINA
R PUI
R1
Q - Flow rate m /h
TERMINAL UNITS
FREECOOLING
50 Hz
SYSTEM ACCESSORIES
CONDENSING UNITS
P = Primary circuit circulation pump. PU = Secondary circuit circulation pump. DPU = Double secondary circuit circulation pump (factory tted accessory). PUI = Secondary circuit circulation inverter pump (factory tted accessory). PZ FL = Flow switch. M = Pressure gauge. = Pit with internal diameter 6.2 mm. MACCHINA PZ PHF = Plate heat exchanger for FREE-COOLING. R1 RA = Buer tank antifreeze heater (factory tted accessory). R = Tap. R1 = Tap to be tted by the installer (provided). S = Water drain/charge tap (outside the buer tank). SA = Water buer tank. VE = Expansion tank calculated to contain the water from the buer tank only (10C +60C). VR = Non-return valve. VS = Safety valve. VSA = Automatic air bleed valve. PZ VSM = Manual air bleed valve. = Connections.
21/2SDSq F
Tank capacity
200
425
PBHI MODEL
0200
0400
RHOSS SEQUENCER
Control of multiple water chillers connected in parallel Summer/winter mode for heat pump units System set-point management Control of all operating parameters Alarm display
The Rhoss Multichiller Sequencer makes it possible to manage water chillers connected in parallel in medium/large HVAC systems. The optimisation of operating times and the insertion of the individual units is controlled by logics that focus on energy eciency, guaranteeing reliability over time. The management mode of the units can be selected from between FL-Full Load Unit Manager (specic for screw compressor water chillers) and PL-Part Load Unit Manager (specic for water chillers with scroll compressors).
The software at the heart of the system was designed and tested by the Rhoss R&D structure and is able to acquire and manage the main variables of the connected water chillers. The sequencer also interfaces with the main BMS available on the market, guaranteeing complete control in all system types.
50% operation
50% operation
50% operation
50% operation
Supervision software
RHOSS SUPERVISOR
119
RHOSS SUPERVISOR is the Rhoss supervision system that allows monitoring and remote management of Rhoss units used in a hydronic system. This makes it possible to monitor, via a computer, the operation of Rhoss chillers, heat pumps or terminal units, or the entire iDRHOSS integrated hydronics system. RHOSS SUPERVISOR is easy to use both in terms of system conguration and access to characteristic unit parameters because it uses the Microsoft Internet Explorer interface.
RHOSS SUPERVISOR makes it possible to set up a local supervision system via serial connection of the microprocessor cards of the RHOSS units to a computer. If the local computer is connected to the information system network of the building (Ethernet with TCP/IP protocol), the information can be shared with any other computer on the network. Supervision can also be carried out remotely via GSM modem connection. In both cases, access to supervisor information can be protected by various levels of password.
RHOSS hydronic unit monitoring and remote control Local supervision on the computer Remove management via the GSM modem
iDRHOSS is an advanced system for the management of hydronic air conditioning systems, developed to meet the comfort needs of any civil or residential location. iDRHOSS oers a series of functions, such as centralised management, automatic summerwinter changeover and operating times, whilst always working towards energy saving.
Flush panel
Area terminal
The control panel for centralised management of all the units in the system.
Group refrigerant
121
Management of daily and weekly time bands (ON/OFF) for the terminals, dierent for each zone, and for the chiller/heat pump with possible variations of set-point. Automatic seasonal switchover and real time status and system operating display in real time (ON/ON by timer - OFF/OFF by timer - OFF by alarm, SUMMER/WINTER/BOILER). Automatic boiler management (and of any bypass valve on the water system) in the event of shutdown of the heat pump. Start-up and shutdown by GSM. Display for the main unit and for the terminal units of possible alarm conditions (identied by a code and corresponding description). Display and setting of current date and time. Conguration of the serial network and of the terminals installed in the zones.
Centralised management of a number of zones and modication of the terminal units (ON/OFF, set-point, operating mode, fan speed, sleep/economy mode).
122
STANDARD CONTROLS
INSTALLATION: KC - C
on board
KC C
KTA - TATM
on board
KTA TATM
KCV2
KCV2
wall mounted
Minimum thermostat
on board
on board
AUTOMATIC SPEED
REGULATION 5C
AUTOMATIC
on board
SPEED MINIMUM
AUTOMATIC
Comfort functions
2-pipe systems
4-pipe systems
Regulation functions
CONTROLS
KICM Recessed electronic panel. The frame is not supplied by Rhoss. KCMS CMS
MASTER circuit board
RIP KRIP
KCMS CMS
KSTI STI Probe for additional coil KMVR MVR ON/OFF valve module KMVR MVR Electric heater module
Additional modules:
Serial interface
Electric heater
Master/slave function
123
RECEIVER
REGULATION FUNCTIONS
FULL AUTO Automatic management. COOL Cooling. DRY Dehumidication. FAN - AUTOFAN Manual/automatic ventilation. HEAT (HEAT+HEATER) Heating (Heating with electric heater).
ADVANCED FUNCTIONS
ECONOMY (ECO) Energy savings. LOCK FUNCTION Locked operation for hotel room. ON/OFF remote control Remote start-up and shutdown. SUMMER/WINTER remote control Summer/winter remote signal SECURITY control External security (window contact). PROBE IN/PROBE OUT Remote working probe. CONTINUOUS VENTILATION Continuous ventilation thermostat. COMFORT CONTROL Regulation +/- 3C OCCUPANCY Occupancy for hotel rooms ALARM Alarm signals. MASTER - SLAVE Master/slave function
MASTER/SLAVE FUNCTION
COMFORT FUNCTIONS
ORIENTING/SWING Fixed/swinging louver. CLOCK Display of set time. TIMER Programmed on/o. SLEEP Night-time air conditioning. HOT START Winter on/o signal CONT
SLAVE 1
SLAVE 2
SLAVE 3
SLAVE 99
Centralised management of a maximum of 5 SLAVE units via a single MASTER unit without a serial interface.
Centralised management of a maximum of 99 SLAVE units via a single MASTER unit without a serial interface.
BRIO-I/BRIO-EV
YARDY-I/YARDY-EV
YARDY-DUCT
YARDY-HP
UTNC-EV
UTNB
UTNA
TERMINAL UNITS CONTROLS COIL UNITS FAN for fan coil units and terminal units
SYSTEM ACCESSORIES
CONDENSING UNITS
MASTER
Fan coils
124
IDROWALL
Cooling capacity: 1.93.9 kW - Heating capacity: 2.85.4 kW
Reduced wall mounted dimensions On board 3-way valve Integrated master/slave function
Versions
MPCV - Heating and cooling unit complete with 3-way ON/OFF valve.
ACCESSORIES CONTROLS
Recessed box. Electronic control panel for wall mounting. Key: Factory tted Supplied loose
SLAVE 1 MASTER SLAVE 2 SLAVE 3 SLAVE 10
125
IDROWALL MODEL Total cooling capacity MAX MED MIN Heating capacity (50C) MAX MED MIN Heating capacity (70C) Air flow speed MAX MAX MED MIN Sound power level MAX MED MIN Sound pressure level MAX MED MIN Maximum absorbed power Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth Weight mm mm mm kg kW kW kW kW kW kW kW m /h m /h m /h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) W V-ph-Hz
20 1,89 1,71 1,42 2,78 2,50 2,06 4,53 480 385 310 50 45 39 42 37 31 44 230-1-50 20 1.010 320 225 14
30 2,95 2,51 1,92 4,01 3,44 2,71 6,54 680 482 350 53 46 41 45 38 33 49 230-1-50 30 1.010 320 225 14
35 3,35 2,80 2,28 4,64 3,95 3,17 7,67 710 570 480 53 47 43 45 39 35 64 230-1-50 35 1.090 330 250 15
40 3,87 2,69 5,36 4,62 3,84 8,56 825 530 54 47 44 46 39 36 70 230-1-50 40 1.090 330 250 15 630 3,30
In the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C. Air: 20C - Water: 50C, ow rate as in cooling. Air: 20C - Water: 70/60C. At 1 m from air outlet with directionality factor of 2.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
BRIO-I
IN
V GREEN IN LINE
ER T ER
Reduced consumption by 50% with respect to a traditional motor Continuous fan speed regulation More quiet operation Enhanced room comfort
BRIO-I Versions
MUP - Horizontal/vertical unit with cabinet equipped with lower air inlet and upper outlet for wall mounting with feet on ground or ceiling installation. MUT - Horizontal/vertical unit with cabinet equipped with front air inlet and upper outlet for oor or ceiling installation.
BRIO-EV Versions
MVP - Vertical unit with cabinet equipped with lower air inlet and upper outlet for wall mounting or with feet on ground. MVT - Vertical unit with cabinet equipped with front air inlet and upper outlet for oor installation. MOP - Horizontal/vertical unit with cabinet equipped with rear air inlet and front ow for ceiling installation, wall-mounting or with feet on ground. MOT - Horizontal/vertical unit with cabinet equipped with lower air inlet and front outlet for ceiling of oor installation.
Models
Fan coils
BRIO-EV
Cooling capacity: 17.6 kW - Heating capacity: 1.310.5 kW
127
CONTROLS
f o r v e -I M r ti ca U l/ P ho
B RI O
HORIZONTAL installation
VERTICAL installation
TERMINAL UNITS
-Mzon i
On board remote control and receiver. Electronic panel for wall or on board mounting. Wall-mounted electronic panel
For installation on machine. Master/slave circuit board. Temperature probe for hot row. Module for management of ON/OFF valves and electric heater. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system.
SYSTEM ACCESSORIES
For wall installation Panel with speed and summer/winter switch. Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electric heater. Minimum temperature thermostat (for installation on the machine).
CONDENSING UNITS
Additional water heating coil. Electric heater. Valve and balancing valve. ON/OFF 2-way valves for 2 and 4-pipe-systems. ON/OFF 3-way valves for 2 and 4-pipe-systems. Auxiliary condensation drain pan. Manual damper. Motorised damper. Rear panel. Rear closure panel. Rear closure panel with grille and lter. Support feet with pipe cover.
For installation on machine ( MVP and MVT versions) Panel with speed switch. Panel with room thermostat, summer/winter switch and speed switch. Minimum temperature thermostat. Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electric heater. Electronic panel with automatic summer/winter changeover for 2-pipe-systems. Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. Interface card for controlling up to 4 fan coil units.
Electronic panel with automatic summer/winter changeover for 2-pipe-systems. Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems.
Exclusive design
Fan coils
128
BRIO-I / BRIO-EV
VERSIONS:
STANDARD
RANGE OF COLOURS:
RHOSS special colours (*)
PEARL WHITE
BI-COLOUR
MONO-COLOUR
SATIN-FINISH BRONZE
GRAPHITE BLACK
RAL COLOURS (*) Customised colour selection It is possible to choose the desired colour from the RAL range. e.g. RAL 2000
METALLIC PURPLE
(*)The RHOSS special colours and the RAL colours are available with BI-COLOUR and MONO-COLOUR set-up.
129
SMIN Heating capacity (50C) Heating capacity additional coil Air flow speed Sound power level Sound pressure level Absorbed power Electrical supply LxHxP - WidthxHeightxDepth Weight mm MAX SMIN MAX SMIN MAX SMIN MAX SMIN MAX SMIN MAX SMIN
0,75 2,47 0,91 2,19 1,00 331 97 48 23 40 15 23,4 5,8 230-1-50 20 800x570x220 20
1,09 3,69 1,42 3,14 1,47 523 167 50 24 42 16 28,0 6,0 230-1-50 30 1000x570x220 21
1,54 5,03 1,81 3,79 1,78 645 198 51 25 43 17 39,0 7,0 230-1-50 40 1200x570x220 28
1,79 8,37 2,24 6,29 2,49 1.235 256 62 27 54 19 98,0 7,0 230-1-50 60 1500x570x220 35
2,11 11,21 3,07 7,52 2,89 300 66 32 58 24 9,0 230-1-50 80 1500x570x220 37 136,0
BRIO-EV MVP-MVT-MOP-MOT MODEL Total cooling capacity kW kW kW Heating capacity (50C) kW kW kW Heating capacity (70C) Heating capacity kW kW kW kW Air flow speed m /h m /h m /h Sound power level dB(A) dB(A) dB(A) Sound pressure level dB(A) dB(A) dB(A) Maximum absorbed power Electrical supply LxHxP- WidthxHeightxDepth Height of feet Weight MUP-MOP for horizontal installation
P H L
15 (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) 0,94 (III) 0,74 (V) 0,62 (VI) 1,30 (III) 1,02 (V) 0,80 (VI) 2,21 (III) 1,34 (III) 1,15 (V) 0,98 (VI) 183 (III) 138 (V) 100 (VI) 40 (III) 33 (V) 30 (VI) 32 (III) 25 (V) 22 (VI) 26 230-1-50 15 100 16 700x 583x 220
20 1,49 (III) 1,14 (V) 1,09 (VI) 1,82 (III) 1,42 (V) 1,26 (VI) 3,39 (III) 1,96 (III) 1,64 (V) 1,47 (VI) 237 (III) 177 (V) 154 (VI) 41 (III) 34 (V) 31 (VI) 33 (III) 26 (V) 23 (VI) 23 230-1-50 20 800x 583x220 100 20
22 1,92 (I) 1,49 (III) 1,14 (V) 2,52 (I) 2,00 (III) 1,56 (V) 4,30 (I) 2,05 (I) 1,81 (III) 1,51 (V) 339 (I) 238 (III) 177 (V) 48 (I) 40 (III) 32 (V) 40 (I) 32 (III) 24 (V) 38 230-1-50 22 100 20
25 2,16 (II) 1,95 (III) 1,56 (V) 2,99 (II) 2,58 (III) 2,08 (V) 5,12 (II) 2,78 (II) 2,37 (III) 1,96 (V) 404 (II) 338 (III) 252 (V) 42 (II) 37 (III) 31 (V) 34 (II) 29 (III) 23 (V) 39 230-1-50 25 100 20
30 2,71 (II) 2,37 (IV) 1,71 (VI) 3,67 (II) 2,99 (IV) 2,26 (VI) 6,27 (II) 2,99 (II) 2,55 (IV) 2,06 (VI) 483 (II) 383 (IV) 281 (VI) 47 (II) 42 (IV) 34 (VI) 39 (II) 34 (IV) 26 (VI) 54 230-1-50 30 100 22
35 3,26 (II) 2,74 (III) 1,99 (VI) 4,24 (II) 3,61 (III) 2,79 (VI) 7,22 (II) 3,40 (II) 3,03 (III) 2,57 (VI) 587 (II) 471 (III) 364 (VI) 48 (II) 43 (III) 35 (VI) 40 (II) 35 (III) 27 (VI) 58 230-1-50 35 100 27
40 3,91 (II) 3,12 (III) 2,70 (V) 4,79 (II) 3,91 (III) 3,19 (V) 8,07 (II) 4,03 (II) 3,40 (III) 3,00 (V) 627 (II) 473 (III) 392 (V) 50 (II) 45 (III) 39 (V) 42 (II) 37 (III) 31 (V) 61 230-1-50 40 100 28
50 4,71 (II) 3,78 (IV) 3,23 (V) 6,08 (II) 4,64 (IV) 4,02 (V) 10,37 (II) 5,46 (II) 4,53 (IV) 4,02 (V) 915 (II) 662 (IV) 536 (V) 56 (II) 47 (IV) 41 (V) 48 (II) 39 (IV) 33 (V) 95 230-1-50 50 100 35
60 5,92 (II) 5,11(IV) 4,28 (V) 7,83 (II) 6,70(IV) 5,87 (V) 13,33 (II) 5,87 (II) 5,67(IV) 5,56 (V) 1.109 (II) 881(IV) 757 (V) 60 (II) 54(IV) 50 (V) 52 (II) 46(IV) 42 (V) 139 230-1-50 60 100 35
75 7,61 (II) 6,57(IV) 6,06(VI) 10,54 (II) 9,52(IV) 18,14 (II) 7,17 (II) 6,82(IV) 6,20(VI) 1.388 (II) 1.171(IV) 65 (II) 60(IV) 57(VI) 57 (II) 52(IV) 49(VI) 173 230-1-50 75 100 36 993(VI) 8,61(VI)
BRIO-EV
additional coil
W V-ph-Hz mm mm kg
800x 583x 220 1000x 583x 220 1000x 583x 220 1200x 583x 220 1200x 583x 220 1500x 583x 220 1500x 583x 220 1500x 583x 220
P H L
BRIO-I and BRIO-EV_In the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C; for BRIO-EV data referred to the speed indicated of the 6 available. Air: 20C - Water: 50C; ow rate as in cooling; for BRIO-EV data referred to the speed indicated of the 6 available. Air: 20C - Water: 70/60C; for BRIO-EV data referred to the speed indicated of the 6 available. At 1 m from air outlet with directionality factor of 2; for BRIO-EV data relative to the speed indicated of the 6 available. SMIN - Super minimum speed.
MUP-MVP-MOP+feet
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
1.503
MAX
kW
1,88
2,86
3,95
6,37
8,01
20
30
40
60
80
YARDY-I
IN
V GREEN IN LINE
ER T ER
Reduced consumption by 50% with respect to a traditional motor Continuous fan speed regulation More quiet operation Enhanced room comfort
Floor and ceiling, recessed or false ceiling fan coils with cabinet.
Construction features
Heat exchanger: with nned coil with left-hand connections reversible to right. Centrifugal fan with an inverter controlled brushless electronic motor and continuous speed adjustment. Structure with cabinet versions: covering cabinet in pre-painted sheet metal complete with renewable lter, grilles in ABS polymer and condensation drain pan with natural drainage. Recessed structure version: in galvanized sheet steel, complete with condensation drain pan with natural drainage and renewable lter.
ACCESSORIES
Versions
MUP - Horizontal/vertical unit with cabinet equipped with lower air inlet and upper outlet for wall mounting with feet on ground or ceiling installation. MUT - Horizontal/vertical unit with cabinet equipped with front air inlet and upper outlet for oor or ceiling installation. IUP - Vertical/horizontal unit equipped with lower air inlet and upper outlet for wall mounted or false ceiling recess installation.
Additional water heating coil. Electric heater. Valve and balancing valve. ON/OFF 2-way valves for 2 and 4-pipe-systems. ON/OFF 3-way valves for 2 and 4-pipe-systems. Auxiliary condensation drain pan. Manual damper. Motorised damper. Rear panel. Rear closure panel. Rear closure panel with grille and lter. Support feet with pipe cover. Frame with lter (G2) that can be extracted in any direction. Outlet straight connection. 90 outlet and inlet connection. Telescopic outlet/inlet connection. Inlet grille with lter. Outlet grille. Cover panel with grilles (only IUP). Flange for connection to duct. Antivibration connection for connection to the inlet or outlet duct. Inlet/outlet plenum with circular nozzles.
UT -
or
P a l i n s t a ll a t i o n IUizont
HORIZONTAL
ER S IO N S
CONTROLS
Remote control receiver. Electronic panel for wall or on board mounting. Wall-mounted electronic panel
installation
VERTICAL
installation
Master/slave circuit board. Temperature probe for hot row. Module for management of ON/OFF valves and electric heater. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Factory tted Supplied loose
f o r v e r ti c a
M U P- M
l/h
131
Temperature set (C)
Time (s)
YARDY-I MUP-MUT-IUP MODEL Total cooling capacity Heating capacity (50C) Heating capacity additional coil Air flow speed Sound power level Sound pressure level Absorbed power Electrical supply DIMENSIONS AND WEIGHTS L - Width MUP-MUT L - Width IUP H - Height MUP-MUT H - Height IUP P - Depth MUP-MUT P - Depth IUP Weight MUP-MUT Weight IUP MUP for horizontal installation mm mm mm mm mm mm kg kg MAX SMIN MAX SMIN MAX SMIN MAX SMIN MAX SMIN MAX SMIN MAX SMIN kW kW kW kW kW kW m /h m /h dB(A) dB(A) dB(A) dB(A) W W V-ph-Hz
20 1,88 0,75 2,47 0,91 2,19 1,00 331 97 48 23 40 15 23,4 5,8 230-1-50 20 800 550 570 545 220 212 20 16,5
30 2,86 1,09 3,69 1,42 3,14 1,47 523 167 50 24 42 16 28,0 6,0 230-1-50 30 1.000 750 570 545 220 212 21 20,5 MUP for vertical installation
40 3,95 1,54 5,03 1,81 3,79 1,78 645 198 51 25 43 17 39,0 7,0 230-1-50 40 1.200 950 570 545 220 212 28 25,5
60 6,37 1,79 8,37 2,24 6,29 2,49 1.235 256 62 27 54 19 98,0 7,0 230-1-50 60 1.500 1.250 570 545 220 212 35 34,5 MUT for vertical installation
80 8,01 11,21 3,07 7,52 2,89 1.503 300 32 58 24 136,0 9,0 230-1-50 80 1.500 1.250 570 545 220 212 36,5 37 66 2,11
IUP for vertical installation MUP+feet In the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C. Air: 20C - Water: 50C, ow rate as in cooling. Air: 20C - Water: 70/60C. At 1 m from air outlet with directionality factor of 2. SMIN - Super minimum speed.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
Traditional Inverter
Fan coils
132
f o r v e r ti c a M l/h O or
YARDY-EV
ONS R SI V E t a l i n s t a ll a t i o n
iz
on
M OP
HORIZONTAL
installation
VERTICAL
Installation exibility Acoustic comfort 6-speed fan Preinstalled accessories and controls
installation
Versions
MVP - Vertical unit with cabinet equipped with lower air inlet and upper outlet for wall mounting or with feet on ground. MVT - Vertical unit with cabinet equipped with front air inlet and upper outlet for oor installation. MOP - Horizontal/vertical unit with cabinet equipped with rear air inlet and front ow for ceiling installation, wall-mounting or with feet on ground. MOT - Horizontal/vertical unit with cabinet equipped with lower air inlet and front outlet for ceiling of oor installation.
ACCESSORIES
Additional water heating coil. Electric heater. Valve and balancing valve. ON/OFF 2-way valves for 2 and 4-pipe-systems. ON/OFF 3-way valves for 2 and 4-pipe-systems. Auxiliary condensation drain pan. Manual damper. Motorised damper. Rear panel. Rear closure panel. Rear closure panel with grille and lter. Support feet with pipe cover.
Panel with speed and summer/winter switch. Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electric heater. Minimum temperature thermostat (for installation on the machine). Electronic panel with automatic summer/winter changeover for 2-pipe-systems. Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. For installation on machine ( MVP and MVT versions) Panel with speed switch. Panel with room thermostat, summer/winter switch and speed switch. Minimum temperature thermostat. Panel with room thermostat, summer/winter switch, ON/OFF valve signal and electric heater. Electronic panel with automatic summer/winter changeover for 2-pipe systems. Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. Interface card for controlling up to 4 fan coil units.
CONTROLS
Remote control receiver. Electronic panel for wall or on board mounting. Wall-mounted electronic panel
Master/slave circuit board. Temperature probe for hot row. Module for management of ON/OFF valves and electric heater. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Factory tted Supplied loose
133
RECEIVER
YARDY-EV MOP-MOT-MVP-MVT MODEL Total cooling capacity kW kW kW Heating capacity (50C) kW kW kW Heating capacity (70C) Heating capacity additional coil Air flow speed kW kW kW kW m /h m /h m /h Sound power level dB(A) dB(A) dB(A) Sound pressure level dB(A) dB(A) dB(A) Maximum absorbed power Electrical supply L - Width H - Height Height of feet P - Depth Weight MOP for horizontal installation W V-ph-Hz mm mm mm mm kg (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed)
15 1,02 (II) 0,87 (IV) 0,62 (VI) 1,41 (II) 1,19 (IV) 0,80 (VI) 2,40 (II) 1,41 (II) 1,16 (IV) 0,80 (VI) 209 (II) 163 (IV) 100 (VI) 43 (II) 35 (IV) 26 (VI) 35 (II) 27 (IV) 18 (VI) 32 230-1-50 15 700 570 100 220 16
20 1,71 (II) 1,32 (IV) 1,09 (VI) 2,20 (II) 1,66 (IV) 1,39 (VI) 3,74 (II) 2,16 (II) 1,72 (IV) 1,47 (VI) 288 (II) 207 (IV) 154 (VI) 44 (II) 35 (IV) 30 (VI) 36 (II) 27 (IV) 22 (VI) 30 230-1-50 20 800 570 100 220 20
22 1,92 (I) 1,49 (III) 1,14 (V) 2,52 (I) 2,22 (III) 1,56 (V) 4,30 (I) 2,07 (I) 1,74 (III) 1,44 (V) 339 (I) 238 (III) 177 (V) 48 (I) 40 (III) 32 (V) 40 (I) 32 (III) 24 (V) 38 230-1-50 22 800 570 100 220 20
25 2,42 (I) 1,95 (III) 1,56 (V) 3,30 (I) 2,58 (III) 2,08 (V) 5,66 (I) 3,01 (I) 2,55 (III) 2,06 (V) 484 (I) 338 (III) 252 (V) 48 (I) 38 (III) 30 (V) 40 (I) 30 (III) 22 (V) 45 230-1-50 25 1.000 570 100 220 20
36 3,10 (I) 2,49 (III) 2,00 (V) 4,00 (I) 3,20 (III) 2,54 (V) 6,82 (I) 3,38 (I) 2,77 (III) 2,29 (V) 546 (I) 433 (III) 328 (V) 50 (I) 42 (III) 36 (V) 42 (I) 34 (III) 24 (V) 60 230-1-50 36 1.000 570 100 220 21
40 3,61 (I) 2,74 (III) 2,38 (V) 4,87 (I) 3,61 (III) 3,10 (V) 8,32 (I) 3,91 (I) 3,40 (III) 3,02 (V) 675 (I) 471 (III) 390 (V) 51 (I) 43 (III) 38 (V) 43 (I) 35 (III) 30 (V) 72 230-1-50 40 1.200 570 100 220 27
45 4,12 (I) 3,19 (III) 2,89 (IV) 5,25 (I) 3,91 (III) 3,61 (IV) 8,88 (I) 3,91 (I) 3,40 (III) 3,02 (IV) 680 (I) 473 (III) 430 (IV) 52 (I) 43 (III) 41 (IV) 44 (I) 35 (III) 33 (IV) 70 230-1-50 45 1.200 570 100 220 28
55 5,23 (I) 4,27 (III) 3,78 (IV) 6,83 (I) 5,47 (III) 4,64 (IV) 11,70 (I) 6,08 (I) 5,13 (III) 4,53 (IV) 1.077 (I) 802 (III) 662 (IV) 58 (I) 52 (III) 47 (IV) 50 (I) 44 (III) 39 (IV) 115 230-1-50 55 1.500 570 100 220 35
65 6,37 (I) 5,28 (III) 4,28 (V) 8,36 (I) 6,90 (III) 5,87 (V) 14,23 (I) 6,29 (I) 5,77 (III) 5,56 (V) 1.234 (I) 947 (III) 757 (V) 62 (I) 56 (III) 50 (V) 54 (I) 48 (III) 42 (V) 161 230-1-50 65 1.500 570 100 220 35
80 7,92 (I) 6,06(VI) 11,11 (I) 9,52(IV) 8,61(VI) 19,11 (I) 7,46 (I) 6,17(VI) 1.480 (I) 1.171(IV) 993(VI) 66 (I) 61(IV) 57(VI) 58 (I) 53(IV) 49(VI) 184 230-1-50 80 570 100 220 37 1.500 6,80(IV) 6,57(IV)
In the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C, data referred to the speed indicated of the 6 available. Air: 20C - Water: 50C; ow rate as in cooling, data referred to the speed indicated of the 6 available. Air: 20C - Water: 70/60C, data referred to the speed indicated of the 6 available. At 1 m from air outlet with directionality factor of 2, data relative to the speed indicated of the 6 available.
MVP-MOP+feet
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
Fan coils
134
O f o r v e r ti c a P l/h or
YARDY-EV
IO N R S t a l i n s t a ll a t i o n E n
iz
o
HORIZONTAL
installation
VERTICAL
Installation exibility Acoustic comfort 6-speed fan Preinstalled accessories and controls
installation
Versions
IVP - Recessed vertical unit equipped with lower air inlet and upper outlet for wall installation. IVF - Recessed vertical unit equipped with lower air inlet and front outlet for wall installation. IOP - Horizontal/vertical unit equipped with rear air inlet and front outlet for wall installation.
Panel with speed and summer/winter switch. Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electric heater. Minimum temperature thermostat (for installation on the machine). Electronic panel with automatic summer/winter changeover for 2-pipe-systems. Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. Interface card for controlling up to 4 fan coil units (for on board installation)
CONTROLS
ACCESSORIES
Remote control receiver. Electronic control panel for wall mounting. Wall-mounted electronic panel
Additional water heating coil. Electric heater. Valve and balancing valve. ON/OFF 2-way valves for 2 and 4-pipe-systems. ON/OFF 3-way valves for 2 and 4-pipe-systems. Auxiliary condensation drain pan. Motorised damper. Frame with lter (G2) that can be extracted in any direction. Outlet straight connection. 90 outlet and inlet connection. Telescopic outlet/inlet connection. Inlet grille with lter. Outlet grille. Cover panel with grilles (only IVF and IOP).
Master/slave circuit board. Temperature probe for hot row. Module for management of ON/OFF valves and electric heater. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Factory tted Supplied loose
RECEIVER
Recessed control panel Remote control with wall-mounted receiver Wall-mounted control panel
135
YARDY-EV IOP-IVP-IVF MODEL Total cooling capacity kW kW kW Heating capacity (50C) kW kW kW Heating capacity (70C) Heating capacity additional coil Air flow speed kW kW kW kW m /h m /h m /h Sound power level dB(A) dB(A) dB(A) Sound pressure level dB(A) dB(A) dB(A) Maximum absorbed power Electrical supply L - Width H - Height P - Depth Weight IOP for horizontal installation W V-ph-Hz mm mm mm kg (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed)
15 1,02 (II) 0,87 (IV) 0,62 (VI) 1,41 (II) 1,19 (IV) 0,80 (VI) 2,40 (II) 1,41 (II) 1,16 (IV) 0,80 (VI) 209 (II) 163 (IV) 100 (VI) 43 (II) 35 (IV) 26 (VI) 35 (II) 27 (IV) 18 (VI) 32 230-1-50 15 450 545 212 14,5
20 1,71 (II) 1,32 (IV) 1,09 (VI) 2,20 (II) 1,66 (IV) 1,39 (VI) 3,74 (II) 2,16 (II) 1,72 (IV) 1,47 (VI) 288 (II) 207 (IV) 154 (VI) 44 (II) 35 (IV) 30 (VI) 36 (II) 27 (IV) 22 (VI) 30 230-1-50 20 550 545 212 16,5
22 1,92 (I) 1,49 (III) 1,14 (V) 2,52 (I) 2,22 (III) 1,56 (V) 4,30 (I) 2,07 (I) 1,74 (III) 1,44 (V) 339 (I) 238 (III) 177 (V) 48 (I) 40 (III) 32 (V) 40 (I) 32 (III) 24 (V) 38 230-1-50 22 550 545 212 16,5
25 2,42 (I) 1,95 (III) 1,56 (V) 3,30 (I) 2,58 (III) 2,08 (V) 5,66 (I) 3,01 (I) 2,55 (III) 2,06 (V) 484 (I) 338 (III) 252 (V) 48 (I) 38 (III) 30 (V) 40 (I) 30 (III) 22 (V) 45 230-1-50 25 750 545 212 20,5
36 3,10 (I) 2,49 (III) 2,00 (V) 4,00 (I) 3,20 (III) 2,54 (V) 6,82 (I) 3,38 (I) 2,77 (III) 2,29 (V) 546 (I) 433 (III) 328 (V) 50 (I) 42 (III) 36 (V) 42 (I) 34 (III) 24 (V) 60 230-1-50 36 750 545 212 20,5
40 3,61 (I) 2,74 (III) 2,38 (V) 4,87 (I) 3,61 (III) 3,10 (V) 8,32 (I) 3,91 (I) 3,40 (III) 3,02 (V) 675 (I) 471 (III) 390 (V) 51 (I) 43 (III) 38 (V) 43 (I) 35 (III) 30 (V) 72 230-1-50 40 950 545 212 24,0
45 4,12 (I) 3,19 (III) 2,89 (IV) 5,25 (I) 3,91 (III) 3,61 (IV) 8,88 (I) 3,91 (I) 3,40 (III) 3,02 (IV) 680 (I) 473 (III) 430 (IV) 52 (I) 43 (III) 41 (IV) 44 (I) 35 (III) 33 (IV) 70 230-1-50 45 950 545 212 25,5
55 5,23 (I) 4,27 (III) 3,78 (IV) 6,83 (I) 5,47 (III) 4,64 (IV) 11,70 (I) 6,08 (I) 5,13 (III) 4,53 (IV) 1.077 (I) 802 (III) 662 (IV) 58 (I) 52 (III) 47 (IV) 50 (I) 44 (III) 39 (IV) 115 230-1-50 55 1.250 545 212 34,5
65 6,37 (I) 5,28 (III) 4,28 (V) 8,36 (I) 6,90 (III) 5,87 (V) 14,23 (I) 6,29 (I) 5,77 (III) 5,56 (V) 1.234 (I) 947 (III) 757 (V) 62 (I) 56 (III) 50 (V) 54 (I) 48 (III) 42 (V) 161 230-1-50 65 1.250 545 212 34,5
80 7,92 (I) 6,06(VI) 11,11 (I) 9,52(IV) 8,61(VI) 19,11 (I) 7,46 (I) 6,17(VI) 1.480 (I) 1.171(IV) 993(VI) 66 (I) 61(IV) 57(VI) 58 (I) 53(IV) 49(VI) 184 230-1-50 80 545 212 36,5 1.250 6,80(IV) 6,57(IV)
In the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C, data referred to the speed indicated of the 6 available. Air: 20C - Water: 50C; ow rate as in cooling, data referred to the speed indicated of the 6 available. Air: 20C - Water: 70/60C, data referred to the speed indicated of the 6 available. At 1 m from air outlet with directionality factor of 2, data relative to the speed indicated of the 6 available.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
Fan coils
136
f o r v e r ti c a
YARDY-DUCT
Cooling capacity: 25 kW - Heating capacity: 2.46.8 kW
l/h
or
n zo
tal
i n s t a ll a t i o n
HORIZONTAL
installation
VERTICAL
installation
Ductable version with six speeds Vertical and horizontal installation Remote control
ACCESSORIES
Additional water heating coil. Electric heater. Valve and balancing valve. ON/OFF 2-way valves for 2 and 4-pipe-systems. ON/OFF 3-way valves for 2 and 4-pipe-systems. Auxiliary condensation drain pan. Motorised damper. Frame with lter (G2) that can be extracted in any direction. Outlet straight connection. 90 outlet and inlet connection. Telescopic outlet/inlet connection. Inlet grille with lter. Outlet grille. Flange for connection to duct. Antivibration connection for connection to the inlet or outlet duct. Inlet/outlet plenum with circular nozzles.
Panel with speed and summer/winter switch. Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electric heater. Minimum temperature thermostat (for installation on the machine). Electronic panel with automatic summer/winter changeover for 2-pipe-systems. Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. Interface card for controlling up to 4 fan coil units (for on board installation).
CONTROLS
Remote control receiver. Electronic control panel for wall mounting. Wall-mounted electronic panel
Master/slave circuit board. Temperature probe for hot row. Module for management of ON/OFF valves and electric heater. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Factory tted Supplied loose
RECEIVER
Recessed control panel Remote control with wall-mounted receiver Wall-mounted control panel
DUCTABLE UNIT
137
kW kW kW kW kW Heating capacity (50C) kW kW kW kW kW kW Heating capacity (70C) Coil heating capacity additional kW kW kW kW kW kW kW Air flow/static pressure m /h / Pa m /h / Pa m /h / Pa m /h / Pa m /h / Pa m /h / Pa Inlet sound power dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) Sound pressure level dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) Maximum absorbed power Electrical supply L - Width H - Height P - Depth Weight W V-ph-Hz mm mm mm kg
(Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed) (Speed)
1,82 (V) 1,54 (IV) 1,39 (III) 1,27 (II) 1,10 (I) 2,41 (VI) 2,21 (V) 1,80 (IV) 1,65 (III) 1,50 (II) 1,30 (I) 4,05 (VI) 2,22 (VI) 2,08 (V) 1,93 (IV) 1,71 (III) 1,60 (II) 1,44 (I) 275 / 56 (VI) 250 / 49 (V) 198 /33 (IV) 180 / 28 (III) 163 / 24 (II) 140 / 18 (I) 47 (VI) 45 (V) 41 (IV) 40 (III) 38 (II) 37 (I) 38 (VI) 36 (V) 32 (IV) 31 (III) 29 (II) 28 (I) 68 230-1-50 40 950 545 212 25,5
2,47 (V) 2,32 (IV) 2,00 (III) 1,75 (II) 1,34 (I) 3,47 (VI) 3,21 (V) 3,02 (IV) 2,52 (III) 2,21 (II) 1,79 (I) 5,94 (VI) 3,54 (VI) 3,34 (V) 3,20 (IV) 2,81 (III) 2,53 (II) 2,14 (I) 450 / 69 (VI) 411 / 58 (V) 382 / 49 (IV) 315 / 36 (III) 270 / 26 (II) 210 / 19 (I) 48 (VI) 46 (V) 45 (IV) 42 (III) 40 (II) 38 (I) 39 (VI) 37 (V) 36 (IV) 33 (III) 31 (II) 29 (I) 94 230-1-50 50 1.250 545 212 34,5
3,43 (V) 3,27 (IV) 3,10 (III) 2,73 (II) 2,49 (I) 4,74 (VI) 4,52 (V) 4,29 (IV) 4,05 (III) 3,70 (II) 3,39 (I) 8,07 (VI) 4,14 (VI) 4,07 (V) 4,00 (IV) 3,98 (III) 3,90 (II) 3,72 (I) 620 / 66 (VI) 587 / 59 (V) 539 / 50 (IV) 504 / 44 (III) 445 / 34 (II) 402 / 28 (I) 54 (VI) 53 (V) 51 (IV) 50 (III) 47 (II) 46 (I) 45 (VI) 44 (V) 42 (IV) 41 (III) 38 (II) 37 (I) 114 230-1-50 60 1.250 545 212 34,5
4,74 (V) 4,51 (IV) 4,28 (III) 4,04 (II) 4,01 (I) 6,51 (V) 6,44 (IV) 6,13 (III) 5,75 (II) 5,71 (I) 5,09 (VI) 4,99 (V) 4,90 (IV) 4,81 (III) 4,59 (II) 4,48 (I) 858 / 54 (V) 820 / 49 (IV) 772 / 45 (III) 715 / 39 (II) 685 / 35 (I) 57 (VI) 55 (V) 54 (IV) 53 (III) 51 (II) 50 (I) 48 (VI) 46 (V) 45 (IV) 44 (III) 42 (II) 41 (I) 154 230-1-50 70 1.250 545 212 36,5 912 / 62 (VI) 11,70 (VI)
TERMINAL UNITS
In the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C. Air: 20C - Water: 50C, ow rate as in cooling. Air: 20C - Water: 70/60C. According to Eurovent 8/12 test. At 1 m from air outlet with directionality factor of 2.
SYSTEM ACCESSORIES
CONDENSING UNITS
6,84 (VI)
kW
(Speed)
1.97 (VI)
2,68 (VI)
3,60 (VI)
4,98 (VI)
YARDY-DUCT MODEL
40
50
60
70
Fan coils
138
f o r v e r ti c a
YARDY-HP
Cooling capacity: 7.220.5 kW - Heating capacity: 9.628 kW
KFGC Flange
l/h
or
n zo
tal
i n s t a ll a t i o n
HORIZONTAL
installation
VERTICAL
installation
Ductable version Vertical and horizontal installation Filters with dierent eciency class Remote control
YARDY HP
Panel with speed and summer/winter switch. Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electric heater. Electronic panel with automatic summer/winter changeover for 2-pipe-systems. Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. Air sensor with remote control option. Interface card for controlling up to 4 fan coil units (models 100150-200 only, for on board installation).
Versions
BA-3R - Unit with 3-row coil. BA-4R - Unit with 4-row coil. BA-5R - Unit with 5-row coil (for mod. 250-300).
CONTROLS
Remote control receiver. Electronic control panel for wall mounting. Wall-mounted electronic panel
ACCESSORIES
Additional water heating coil (1 row) for 4-pipe systems (KBAA for version BA-3R only). External plenum with additional water heating coil for 4-pipe systems (PBAB). ON/OFF 2-way valves for 2-pipe and 4-pipe systems. On/OFF 3-way valves for 2-pipe and 4-pipe systems. Auxiliary condensation drain pan. Frame with lter that can be extracted in any direction (eciency rating G1/G2/G3). Straight outlet and inlet connection. 90 outlet and inlet connection. Flange for connection to duct. Antivibration connection for connection to the inlet/outlet duct. Panel with circular nozzles to be connected to the outlet/inlet connections.
Master/slave circuit board. Temperature probe for hot row. Module for management of ON/OFF valves and electric heater. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Factory tted Supplied loose
RECEIVER
Recessed control panel Remote control with wall-mounted receiver Wall-mounted control panel
DUCTABLE UNIT
139
YARDY HP MODEL Total cooling capacity Heating capacity (50C) Total cooling capacity Heating capacity (50C) Total cooling capacity Heating capacity (50C) Heating capacity of additional coil (70C) Heating capacity of additional coil (70C) Air flow/Speed static pressure (BA-3R) BA-3R BA-3R BA-4R BA-4R BA-5R BA-5R KBAA PBAB kW kW kW kW kW kW kW kW
100 7,16 9,62 8,41 10,84 6,69 12,90 1.552 / 60 1.369 / 50 1.013 / 35 62 60 57 48 46 43 270 230-1-50 100 mm mm mm mm kg 1.295 250 555 200 40
150 8,37 11,71 9,51 12,71 6,78 14,14 1.840 / 60 1.430 / 50 1.313 / 35 63 62 60 49 48 46 340 230-1-50 150 1.295 250 555 200 40
200 10,13 14,28 11,37 15,42 9,35 16,40 2.339 / 60 1.717 / 50 1.414 / 35 63 61 58 49 47 44 400 230-1-50 200 1.295 285 670 200 50
250 13,53 19,06 16,55 22,28 18,70 24,90 10,44 29,73 3.312 / 60 2.189 / 50 1.329 / 35 65 60 57 51 46 43 700 230-1-50 250 1.295 335 720 200 56
300 15,23 18,75 25,70 20,50 28,04 11,31 32,77 3.075 / 50 2.415 / 35 69 65 63 55 51 49 710 230-1-51 300 1.295 335 200 56 720 3.875 / 60 21,79
MED m /h / Pa MIN m /h / Pa Inlet sound power (BA-3R) MAX MED MIN Speed sound pressure (BA-3R) MAX MED MIN Maximum absorbed power (BA-3R) Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height P - Depth YARDY HP P - Depth PBAB Weight YARDY HP dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) W V-ph-Hz
TERMINAL UNITS
In the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C. Maximum speed. Air: 20C - Water: 50C, ow rate as in cooling. Maximum speed. Air: 20C - Water: 70/60C. Maximum speed. 3-row coil (BA-3R) without lter. With G2 lter according to Eurovent 8/12 test. At 2 m from the air outlet point with directionality factor of 2 and G2 lter.
SYSTEM ACCESSORIES
CONDENSING UNITS
MAX m /h / Pa
Fan coils
140
UTNC-EV
Cooling capacity: 2.49.6 kW - Heating capacity: 3.213 kW
New more quiet range Versions for 2-pipe, 4-pipe and electric heater systems Preinstalled 3-way valve on demand
Cassette-type fan coil units
Construction features
Fan coils: cassette-type for installation in false ceilings, with air inlet and outlet directly into the room. Heat exchanger: with nned coil. Fan: 3-speed. Structure: load-bearing, in galvanised sheet metal, complete with condensation drain pump (up to 200 mm above the unit). Damping panel: in ABS polymer with manually adjustable outlet ns, inlet grille and renewable lter.
Panel with speed and summer/winter switch. Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal and electric heater. Electronic panel with automatic summer/winter changeover for 2-pipe-systems. Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. Interface card for controlling up to 4 fan coil units.
Versions
CONTROLS
Standard - for 2-pipes-systems . V3 - for 2-pipe-systems with 3-way ON/OFF valve. B4 - for 4-pipe systems. V3B4 - for 4-pipe-systems with 3-way ON/OFF valve. REL - for 2-pipes-systems supplementary electric heater.
Remote control. Electronic control panel for wall mounting. Wall-mounted electronic panel
On/OFF 3-way valve for 2-pipe and 4-pipe systems. ON/OFF 2-way valves for 2-pipe and 4-pipe systems. Primary air kit. Outlet nozzle lock. Photocatalytic and passive electrostatic lter.
Master/slave circuit board. Temperature probe for hot row. Module for management of ON/OFF valves and electric heater. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Supplied loose
Recessed control panel Remote control with bracket for wall installation Wall-mounted control panel
141
UTNC-EV MODEL 26 Total cooling capacity MAX MED MIN Heating capacity (50C) MAX MED MIN Heating capacity (70C) Heating capacity additional coil B4 Electric heater REL Air flow speed MAX MAX MED MIN 230-1-50 V MAX MED MIN Sound power level MAX MED MIN Sound pressure speed MAX MED MIN Maximum absorbed power Electrical supply DIMENSIONS AND WEIGHTS UTNC - LxH1/H2xP Dimensions Panelling - Lxh1/h2xP Dimensions Weight UTNC - UTNC/REL Weight UTNC/B4 Panelling weight mm mm kg kg kg kW kW kW kW kW kW kW kW kW kW kW m /h m /h m /h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) W V-ph-Hz 2,40 1,80 1,55 3,20 2,50 2,20 5,33 1,50 660 450 360 47 37 32 38 28 23 58 230-1-50 26 41 4,00 2,90 1,90 5,00 4,00 2,50 8,39 2,50 735 505 320 52 44 32 43 35 23 54 230-1-50 41
UTNC-EV UTNC-EV REL 51 4,70 3,50 2,85 6,20 4,60 3,70 12,87 2,50 900 625 485 57 48 42 48 39 33 94 230-1-50 51 61 6,30 4,50 3,40 8,11 6,00 4,50 13,63 3,00 980 720 530 47 40 34 38 31 25 63 230-1-50 61 86 7,20 5,50 3,70 10,00 7,40 4,60 16,89 3,00 1160 825 500 53 46 37 44 37 28 85 230-1-50 86 111 9,60 6,60 4,05 13,00 9,30 5,20 21,87 3,00 1600 1080 600 61 52 40 52 43 31 185 230-1-50 111 26 2,20 1,65 1,45 1,90 1,44 1,24 660 450 360 47 37 32 38 28 23 58 230-1-50 26
UTNC-EV B4 41 3,50 2,70 2,00 6,37 5,10 3,60 735 505 320 54 45 33 45 36 24 54 230-1-50 41 51 4,10 3,25 2,60 6,80 5,80 5,00 900 625 485 57 48 42 48 39 33 94 230-1-50 51 111 6,80 3,80 11,50 7,30 1600 1080 600 61 52 40 52 43 31 185 111 825x282/298x885 960x55/35x960 16,5 3 40,6 5 230-1-50 16,00 9,10
In the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C. Air: 20C - Water: 50C, ow rate as in cooling. Air: 20C - Water: 70/60C. At 1 m from air outlet with directionality factor of 2.
h2
h1
TERMINAL UNITS
H2
H1
SYSTEM ACCESSORIES
CONDENSING UNITS
Fan coils
142
VTNC
Cassette for 2-pipes systems Adjustable movable ns Remote control supplied as standard. Centralised control panel
Electronic control panel for wall mounting. Centralised control panel for up to 64 units via a serial connection, with daily and weekly time band management. Serial interface for connection with the control panel (proprietary protocol). Key: Supplied loose
Versions
MANAGEMENT OF UP TO 64 UNITS VIA A SERIAL CONNECTION Centralised control panel with daily/weekly time bands management.
143
VTNC MODEL Total cooling capacity MAX MED MIN Heating capacity (50C) MAX MED MIN Air flow speed MAX MED MIN Sound power level MAX MED MIN Sound pressure speed MAX MED MIN Maximum absorbed power Electrical supply DIMENSIONS AND WEIGHTS L2/H1/H2/P2 - Width 2/Height 1-2/Depth 2 L/H/P - Width/Height/Depth mm Weight VTNC Panelling weight kg kg mm kW kW kW kW kW kW m /h m /h m /h dB(A) dB(A) dB(A) dB(A) dB(A) dB(A) W V-ph-Hz
VTNC 26 2,91 2,54 2,17 3,88 3,40 2,98 560 490 380 54 47 41 46 39 33 50 230-1-50 26 575/265/285/575 647/30/647 18 2,5
VTNC 36 3,59 3,05 2,69 4,95 4,20 3,73 690 540 440 59 52 46 51 44 38 70 230-1-50 36 575/265/285/575 647/30/647 18 2,5
VTNC 46 4,37 3,50 2,96 5,82 4,66 3,97 840 570 470 63 56 48 55 48 40 90 230-1-50 46 575/265/285/575 647/30/647 18 2,5
VTNC 60 5,80 4,86 4,04 6,89 5,21 4,10 1.024 733 460 56 51 45 48 43 37 100 230-1-50 60 840/230/245/840 950/35/950 29 6,0
VTNC 85 6,94 6,04 9,42 8,37 7,77 1.460 1.041 64 58 56 56 50 48 170 230-1-50 85 840/300/315/840 950/35/950 30 6,0 1.228 7,83
In the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C. Air: 20C - Water: 50C, ow rate as in cooling. Air: 20C - Water: 70/60C. At 1 m from air outlet with directionality factor of 2.
H2
TERMINAL UNITS
h2
h1
H1
SYSTEM ACCESSORIES
CONDENSING UNITS
144
UTNB 011017
Cooling capacity: 4.110.5 kW - Heating capacity: 5.913.6 kW Complete composition
(*) Unit dimensions in combination with KPAM plenum .
STANDARD CONTROLS
For wall installation Panel with speed and summer/winter switch. Panel with room thermostat, summer/winter switch, speed switch, ON/OFF valve signal. Humidistat panel. Electronic panel with automatic summer/winter changeover for 2-pipe-systems. Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems. Interface card for controlling up to 4 fan coil units.
CONTROLS
Additional water heating coil. inlet/outlet plenum (KPAM). Electric coil module of 1.5-3-4.5 kW (KBAE). Plenum with steam humidier (KUMI). Outlet nozzles module (KBOM). Inlet panelling. Solid panelling. Outlet panelling.
Remote control receiver. Electronic control panel for wall mounting. Wall-mounted electronic panel For installation on machine. Master/slave circuit board. Temperature probe for hot row. Module for management of ON/OFF valves and electric heater. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Supplied loose
RECEIVER
Recessed control panel Remote control with wall-mounted receiver Wall-mounted control panel
INDOOR INSTALLATION
DUCTABLE UNIT
145
Heating capacity Heating capacity of additional coil Air flow speed MAX MED MIN Sound pressure speed MAX MED MIN Maximum absorbed power Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height KPAM - Depth UTNB - Depth KBAE - Depth KUMI - Depth KBOM - Depth Weight UTNB kg
5,92 10,02 1.100 990 850 41 40 38 165 230-1-50 011 2R 990 290 290 738 130 290 100 38
8,75 10,02 1.100 990 850 41 40 38 165 230-1-50 011 4R 990 290 290 738 130 290 100 42
9,58 10,02 1.100 990 850 41 40 38 165 230-1-50 011 6R 990 290 290 738 130 290 100 46
7,17 12,37 1.480 1.260 1.100 47 44 41 205 230-1-50 014 2R 990 290 290 738 130 290 100 38
11,02 12,37 1.480 1.260 1.100 47 44 41 205 230-1-50 014 4R 990 290 290 738 130 290 100 42
12,27 12,37 1.480 1.260 1.100 47 44 41 205 230-1-50 014 6R 990 290 290 738 130 290 100 46
7,76 13,49 1.680 1.440 1.200 50 46 41 245 230-1-50 017 2R 990 290 290 738 130 290 100 40
12,12 13,49 1.680 1.440 1.200 50 46 41 245 230-1-50 017 4R 990 290 290 738 130 290 100 44
13,59 13,49 1.680 1.440 1.200 46 41 245 230-1-50 017 6R 290 290 738 130 290 100 48 990
In the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C. Maximum speed, with open outlet. - Air: 20C - Water: 70/60C. - At 3 m from the point of air outlet, with open outlet.
Air: 20C - Water: 50C, ow rate as in cooling. Maximum speed, with open outlet.
NOVELTIES
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
50
kW
4.11
6,76
7,78
4,82
8,23
9,64
5,14
8,92
10,52
UTNB MODEL
011 2R
011 4R
011 6R
014 2R
014 4R
014 6R
017 2R
017 4R
017 6R
146
UTNA 015150
Cooling capacity: 7.2108 kW - Heating capacity: 10.5128.7 kW Complete composition
NOVELTIES
BRUSHLESS EC Version High eciency lters F7 Direct expansion coil even in reversible version
KSER Damper
KPBC Panel with circular nozzles KPBM Panel with outlet nozzle
Combined fresh air damper (max 25%) and re-circulation, to be attached to the PMA inlet plenum. Solid pre-cut panel for connection to duct, to be attached to the PMA inlet plenum. Panel with rectangular outlet nozzle with double row of adjustable ns, to be attached to PMA outlet plenum. Panel with circular nozzles, to be attached to PMA inlet/outlet plenum (only for models 015051). Manual control for KSER damper. Electrical panel in waterproof box (IP55 for UTNA 015038).
Panel with speed and summer/winter switch. Panel with room thermostat, summer/winter switch, speed switch, ON/ OFF valve signal. Humidistat panel. Electronic panel with automatic summer/winter changeover for 2-pipe-systems. Electronic panel with automatic summer/winter changeover and automatic speed regulation for 2-pipe-systems with electric heater or 4-pipe-systems.
CONTROLS
Remote control receiver. Electronic control panel for wall mounting. Wall-mounted electronic panel
Accessory modules
Inlet/outlet plenum with pre-cut side outlets (PMA). Plenum with absorbent cartridge silencer to be placed for inlet or outlet (SIL). Plenum with steam humidier and external electric generator (MUV PRV). Module with F7 high eciency lter (combines with SV-EC).
Additional water heating coil to be inserted in module BA. Supplementary electric heater from 1.5 kW to 36 kW, to be inserted in module BA. Droplet eliminator for models 078150, to be inserted in module BA.
Master/slave circuit board. Temperature probe for hot row. Module for management of ON/OFF valves and electric heater. Serial interfaces for connection to BMS (proprietary protocol, Modbus RTU). Serial converters (RS485/RS232, RS485/USB) in the case of centralised unit management. Serial interface (CAN-bus - Controller Area Network) for the iDRHOSS system. Key: Factory tted Supplied loose
INDOOR INSTALLATION
DUCTABLE UNIT
147
RECEIVER
UTNA MODEL Heating. capacity of additional coil BA 2R/KB2R Cooling capacity Heating capacity Cooling capacity Heating capacity Electric heater power electric Cooling capacity Heating capacity Air flow speed standard fan Std. fan static pressure speed Sound pressure speed standard fan BA-4R BA 4R BA 6R BA 6R kW kW kW kW kW
015 11,3 7,2 10,5 9,9 13,3 1,5-3-4,5 1,5-3-4,5 11,7 12,8 1.800 1.370 1.060 90 50,9 44,3 37,1 370 1000-2000 Pa V-ph-Hz mm mm mm mm mm mm kg 150 230-1-50 015 928 398 370 645 370 960 51
020 14,2 8,8 13,4 12,5 17,7 3-4,5-6 3-4,5-6 16,0 17,4 2.640 2.240 1.480 90 55,6 50,2 42,1 700 1400-2700 150 230-1-50 020 928 398 370 645 370 960 51
029 20,7 13,9 19,3 17,9 24,0 4,5-6-9 4,5-6-9 19,0 19,6 3.220 2.400 1.560 90 54,9 48,3 38,7 700 1500-3200 150 230-1-50 029 1.228 463 435 645 435 960 68
038 25,8 17,3 24,6 22,4 30,6 6-9-12 6-9-12 25,2 26,0 4.260 3.500 2.850 90 59,8 55,7 51,4 1.250 2700-4300 150 230-1-50 038 1.228 518 490 645 490 960 71
051 35,2 21,4 32,4 30,9 42,5 9-12-18 34,5 36,1 6.120 4.390 130 61,5 54,4 1.850 3500-6000 150 400-3-50 051 1.328 568 540 645 490 960 79
078 57,5 41,8 54,4 55,6 67,3 12-18-24 47,3 49,7 8.580 (*) 170 59,7 1.500 400-3-50 078 1.658 768 740 910 1.040 1.040 140
107 82,6 60,6 77,9 82,7 96,7 18-24-36 55,6 58,3 11.770 (*) 160 61,7 1.500 400-3-50 107 2.058 918 890 910 1.040 1.040 200
130 92,7 67,8 88,9 94,4 112,3 18-24-36 61,0 64,7 14.300 (*) 145 65,4 2.200 400-3-50 130 2.058 918 890 910 1.040 1.040 200
150 106,0 101,6 108,0 128,7 24-36 68,0 16.500 (*) 140 61,9 3.000 400-3-50 150 2.058 990 910 1.040 1.040 220 1.018 72,1 77,1
230V-1ph-50Hz kW 400V-3ph-50Hz kW BA DX BA DX MAX MED MIN MAX MAX MED MIN W W m /h m /h m /h Pa dB(A) dB(A) dB(A) W
Standard fan absorbed power EC brushless fan air flow Static pressure speed Electrical supply DIMENSIONS AND WEIGHTS L - Width H - Height PMA - Depth BA - Depth SV - Depth SIL-MUV - Depth Weight UTNA m /h
In the following conditions: Air: 27C D.B.; 19C W.B. - Water: 7/12C. Maximum speed. Air: 20C - Water: 50C, ow rate as in cooling. Maximum speed. Air: 20C - Water: 70/60C. 4-row coil (BA 4R) and lter G3. At 3 m from the point of air outlet, with open outlet. Empty weight BA 6R. Temperature inlet air 27C; 19 BU; MAX. speed Coil temperature inlet air 20C;MAX. speed (*) Belt transmission with variable ratio.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
148
UTNA 015150
Cooling capacity: 7.2108 kW - Heating capacity: 10.5128.7 kW
BA Coil module SV Fan module
NOVELTIES
Base composition
PDP: dirty lters signal dierential pressure switch (standard). TAG: mixed coil antifreeze thermostat management (with BA2R; BA4R; BA6R). TM: air supply limit temperature probe (standard). TUAMB: room temperature/humidity probe for air units set-point management with MUV and PRV. V1: mixed coil uid regulation kit with 3-way valve and servocommand (with BA2R; BA4R; BA6R). V2: post-heating coil uid regulation kit with 3-way valve and servo-command (with KB2R). VDX: direct expansion coil regulation. RE: additional electric heater regulation (with KR). PRV: modulating steam humidier management (with MUV and PRV). VM: supply fan management (standard). VM_EC: BRUSHLESS EC Motor supply fan management. RU: room control panel (standard). QE: power and regulation electrical panel (standard). Interface: the units are directly interfaced via Modbus RTU protocol.
INDOOR INSTALLATION
UTNA VM
DUCTABLE UNIT
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
149
150
High eciency heat recovery High eciency lters F7 Contained dimensions Horizontal or vertical conguration
Fresh air terminal units with crossed ows static heat recovery.
Construction features
Recovery unit: with aluminium plates, static, high performance (UTNR-A) or in special paper (UTNR-P) with air ows kept separate by special sealing. The recovery unit can be removed from the lower part in the horizontal conguration. Fans: double inlet, centrifugal, fresh air intake and expulsion (for model 033 wit simple intake) with an electric directly coupled motor. Ventilating body installed on antivibration mountings to avoid transmitting vibrations. Structure: load-bearing structure and side panels (can be removed completely in the horizontal conguration) in Aluzink sheet metal. Filtering section: consisting of two lters (one on the fresh air inlet and one on the environment air return), both regenerable acrylic class G4 with contained pressure drops. Laterally removable lters in the horizontal conguration. Insulation: acoustic and thermal panel insulation with polyethylene/polyester having an average thickness of 20 mm. Terminal board: already present on the machine to facilitate the electrical connections. Condensation drain tray: in ABS with the condensate drain connection from the bottom. Free cooling or defrost by-pass: a by-pass system can be set in the horizontal conguration for models 110410 to control the free cooling or defrost thanks to a suitable pre-cut.
Versions
UTNR-A/O 03 Crossed ows static recovery unit with an aluminium heat exchanger in the horizontal conguration and direction 03 (nominal eciency up to 57%). UTNR-P/O 03 Crossed ows static recovery unit with a heat exchanger consisting of sheets of special paper in the horizontal conguration and direction 03 (nominal eciency up to 76%).
ACCESSORIES
BER - Post-heating electric heater. BCR - Post-heating internal water coil (mod. 110-410). KSBFR - Water coil section. KF7 - High eciency lters. KSRE - Regulation damper. RMS - Section 3 mixture/recirculation dampers. SSC - Channel silencers.
STANDARD CONTROLS
KVVM - Electronic speed regulator (mod. 033-055). KVC2 - Speed selector (mod. 110320). KTCV2 - Unit control panel. KSTC - Star-delta switch (mod. 410). PF - Dirty lters signal pressure switch. ATG - Antifreeze thermostat.
INDOOR INSTALLATION
DUCTABLE UNIT
151
UTNR-A/UTNR-P MODEL TECHNICAL DATA Head Pressure Sound pressure level Electric absorption Electrical supply UTNR-P HEAT RECOVERY ON PAPER Efficiency (temp/enthalpy) Recovered heating capacity UTNR-A HEAT RECOVERY ON ALUMINIUM Efficiency (temp/enthalpy) Recovered heating capacity ACCESSORIES Heating capacity BER Heating capacity BCR Heating capacity KSBFR Total cooling capacity KSBFR DIMENSIONS AND WEIGHTS L/H/P - Width/Height/Depth UTNR-A/P Weight UTNR-A/P L/H/P - Width/Height/Depth KSBFR Weight KSBFR mm kg mm kg KW KW KW KW % kW % kW Pa dB(A) W V-ph-Hz Nominal air flow rate m /h
110 920 65 50 2 x 147 230-1-50 72/56 7,2 55 4,7 3 8,2 12 5 110 1.140/410/860 80 500/410/450 17
175 1.580 70 53 2 x 350 230-1-50 68/55 12,2 54 7,9 6 12,2 19,7 8,8 175 1.300/500/860 125 600/500/450 21
220 1.850 77 52 2 x 350 230-1-50 73/65 16,9 54 9,2 6 14,4 23,7 11,1 220 138 700/500/480 24
255 2.250 80 51 2 x 350 230-1-50 75767 21,1 54 11,2 12 20,3 30,5 14,7 255 160 700/600/660 29
320 2.950 100 54 2 x 550 230-1-50 70/62 25,6 51 13,9 12 24,2 37 17,4 320 174 700/600/660 29
1.380/500/960 1.650/600/1.230
1.650/600/1.230 1.750/600/1.330
In the following conditions: Values with reference to 1.5 metres from the intake in free eld. Nominal winter conditions: outdoor air: -5C; 80% UT. Environmental air: 20C; 50% RH Air T in = 8C. Air T in = 8C; water T in out = 70/60C. Air T in: 30C; 50% RH; water T in out =7/12C.
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
30,8
Filter
Filter
HORIZONTAL installation
VERTICAL installation
152
UTNR-HE 033410
Air ow rate: 3104,290 m/h
ACCESSORIES
BER - Post-heating electric heater. KSBFR - Water coil section. KF7 - High eciency lters. KSRE - Regulation damper. RMS - Section 3 mixture/recirculation dampers. SSC - Channel silencers.
STANDARD CONTROLS
KVVM - Electronic speed regulator (mod. 033 - 055). KVC2 - Speed selector (mod. 110320). KTRHE - Unit control panel. KSTC - Star-delta switch (mod. 410). PF - Dirty lters signal pressure switch. ATG - Antifreeze thermostat.
Versions
UTNR-HE 01 heat recovery unit with aluminium rotary exchanger with direction 01 (eciency up to 90%).
INDOOR INSTALLATION
DUCTABLE UNIT
153
UTNR-HE MODEL TECHNICAL DATA Head Pressure Sound pressure level Electric absorption Electrical supply Winter efficiency (temp/enthalpy) Winter recovered heating capacity Summer efficiency (temp/enthalpy) Summer recovery heating capacity ACCESSORIES Heating capacity BER Heating capacity KSBFR Cooling capacity KSBFR DIMENSIONS AND WEIGHTS L/H/P - Width/Height/Depth UTNR-HE Weight UTNR-HE L/H/P - Width/Height/Depth KSBFR Weight KSBFR mm kg mm kg KW KW KW Pa dB(A) W V-ph-Hz % kW % kW Nominal air flow rate m /h
33 310 50 40 2 x 92 230-1-50 85/82 3,5 92/73 1,3 1,5 4,5 2,1 33 1075/425/750 67 430X290X395 14
55 650 65 48 2 x 90 230-1-50 72/69 6,3 80/69 2,5 3 7,9 3,6 55 1075/425/750 71 430X290X395 14
110 1.050 80 47 2 x 147 230-1-50 71/68 10 79/69 4 3 12,3 5,4 110 1205/460/860 102 500X410X450 17
175 1.800 130 46 2 x 350 230-1-50 72/69 17,4 80/69 6,9 6 19,7 9,5 175 1400/530/860 139 600X500X450 21
220 2.220 100 50 2 x 350 230-1-50 72/69 21,3 79/69 8,5 6 24,8 12,4 220 152 700X500X480 24
255 2.600 110 48 2 x 350 230-1-50 72/69 25,2 80/69 10 12 31,5 16,1 255 178 700X600X660 29
320 3.250 125 50 2 x 550 230-1-50 69(67 30,5 77/68 12,3 12 36,4 18,5 320 194 29
410 4.290 130 54 2 x 750 400-3-50 63/63 38 15,7 12 45,4 22,1 410 207 34 70/66
TERMINAL UNITS
In the following conditions: Values with reference to 1.5 metres from the intake in free eld. Nominal winter conditions: outdoor air: -5C; 80% UT. Environmental air: 20C; 50% RH Nominal summer conditions: outdoor air: 32C; 50%UT. Environmental air: 26C; 50% RH Air T in = 8C. Air T in = 8C; water T in out = 70/60C. Air T in: 30C; 50% RH; water T in out =7/12C.
SYSTEM ACCESSORIES
CONDENSING UNITS
154
VMC-E 015100
Air ow rate: 1501,000 m/h
Fresh air terminal unit with countercurrent ows static heat recovery.
Construction features
Recovery unit: thanks to a high performance static-type exchanger with countercurrent ows consisting of at layers of special paper that allow total heat exchange, thereby recovering both sensitive and latent heat. The air ows are kept separate by special sealing. Maintenance is easily performed on the exchanger and lters thanks to the lateral extraction. Fans: fresh air inlet and centrifugal expulsion with BRUSHLESS DC motors that allow higher eciency to be achieved with respect to traditional motors with an energy saving of up to 60%. Free cooling by-pass: possibility of setting up the free-cooling in mid-season thanks to the relative automatic by-pass function.
Controls
KCVE: remote panel with ON/OFF function, speed selection and programmable weekly timer. It is suitable for wall installation on "502" electrical boxes. KTLCM: infrared remote control.
Expelled air
Fresh air
EXTERNAL
INTERNAL
Fresh air
Expelled air
INDOOR INSTALLATION
DUCTABLE UNIT
155
VMC MODEL Air flow rate Speed Head Pressure Speed Electric absorption Speed Sound pressure level return. Speed Electrical supply Winter efficiency (temp/enthalpy) Winter recovered heating capacity Summer efficiency (temp/enthalpy) Summer recovered heating capacity MAX (V) MED (V) MIN (V) MAX (V) MED (V) MIN (V) MAX (V) MED (V) MIN (V) MAX (V) MED (V) MIN (V) m /h m /h m /h Pa Pa Pa W W W dB(A) dB(A) dB(A) V-ph-Hz % kW % kW
50 500 500 360 100 60 30 135 110 60 33 31 27 230-1-50 77/63 4,3 62,5/60 1,7
80 800 800 625 150 100 40 300 190 110 38 36 32 230-1-50 73/59 6,5 59/57 2,5
100 1.000 650 150 100 40 310 200 39 37 33 230-1-50 74/60 8,2 59,5/57,5 3,2 125 780
In the following conditions: Values with reference to 1.5 metres from the intake in free eld. Nominal winter conditions: outdoor air: -5C; 80% UT. Environmental air: 20C; 50% RH Nominal summer conditions: outdoor air: 32C; 50% UT. Environmental air: 26C; 50% RH
TERMINAL UNITS
SYSTEM ACCESSORIES
CONDENSING UNITS
2012-2013
APPLIED SYSTEMS
Product Catalogue
RHOSS S.P.A. Via Oltre Ferrovia, 32 - 33033 Codroipo (UD) - Italy tel. +39 0432 911611 - fax +39 0432 911600 rhoss@rhoss.it - www.rhoss.it - www.rhoss.com IR GROUP S.A.S.U. 19, chemin de la Plaine - 69390 Vourles - France tl. +33 (0)4 72 31 86 31 - fax +33 (0)4 72 31 86 30 exportsales@rhoss.it
RHOSS S.P.A. declines all responsibility for possible mistakes in this document and reserves the right to alter the features of their products without notice.
RHOSS Deutschland GmbH Hlzlestrae 23, D-72336 Balingen, OT Engstlatt - Germany tel. +49 (0)7433 260270 - fax +49 (0)7433 2602720 info@rhoss.de - www.rhoss.de RHOSS GULF JLT Jumeirah Lakes Towers, Dubai UAE e-mail: info@rhossgulf.com Commercial offices Italy: Codroipo (UD) 33033 Via Oltre Ferrovia, 32 tel. +39 0432 911611 - fax +39 0432 911600 Agrate Brianza (MI) 20041 Centro Colleoni - Palazzo Taurus, 1 tel. +39 039 6898394 - fax +39 039 6898395
Rhoss is involved in the Eurovent certification programme. The products in question are included in the guide to Eurovent certified products, which can be found at www.eurovent-certification.com - www.certiflash.com