5—1996
Australian Standard
This is a free 6 page sample. Access the full version at http://infostore.saiglobal.com.
Review of Australian Standards. To keep abreast of progress in industry, Australi an Standards are subject
to periodic review and are kept up to date by the issue of amendments or new editi ons as necessary. It is
important therefore that Standards users ensure that they are in possession of the latest editi on, and any
amendments thereto.
Full detail s of all Australi an Standards and related publications will be found in the Standards Australi a
Catalogue of Publications; this information is supplemented each month by the magazine ‘The Australi an
Standard’, which subscribing members receive, and which gives details of new publications, new editi ons
and amendments, and of withdrawn Standards.
Suggesti ons for improvements to Australian Standards, addressed to the head offi ce of Standards Australi a,
are welcomed. Noti fi cati on of any inaccuracy or ambiguity found in an Australian Standard should be made
without delay in order that the matter may be investigated and appropriate action taken.
Australian Standard
This is a free 6 page sample. Access the full version at http://infostore.saiglobal.com.
PREFACE
This Standard was prepared by the Joint Standards Australia/Standards New Zealand
Committee FP/4 on Automatic Sprinkler Installations, to supersede in part
AS 2118 —1988, SAA Code for Automatic Fire Sprinkler Systems.
This Standard is the result of a consensus among representatives on the joint committee to
produce it as an Australian Standard.
The revisions to AS 2118 have included Standards Australia’s requirements to keep
product and installation Standards separate. When complete the series will comprise the
following:
AS
2118 Automatic fire sprinkler systems
Part 1: Standard
This is a free 6 page sample. Access the full version at http://infostore.saiglobal.com.
CONTENTS
Page
SECTION 1 SCOPE AND GENERAL
1.1 SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . ... .. .. .. .. ... ........ 4
1.2 NEW DESIGNS AND INNOVATIONS . . . .. .. .. .. ... . ........... 4
1.3 DEEMED TO SATISFY . . . . . . . . . . . . . . ...... .. .... . ... .. .. .. . 4
1.4 REFERENCED DOCUMENTS . . . . . . . . . .. ... . .. .... ...... ... .. 4
1.5 DEFINITIONS . . . . . . . . . . . . . . . . . . . . . .... .. .. .. .. . ... .. ..... 5
SECTION 2 REQUIREMENTS
2.1 NOMINAL SIZES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2 CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.3 RATED WORKING PRESSURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.4 BODIES AND COVERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
This is a free 6 page sample. Access the full version at http://infostore.saiglobal.com.
2.5 STRENGTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.6 DRAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.7 ACCESS FOR MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.8 COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.9 LEAKAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.10 NON-METALLIC COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.11 SEALING ASSEMBLY ELEMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
2.12 CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.13 OPERATIONAL PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2.14 WET PILOT HEIGHT LIMITATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.15 ALARMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.16 HYDRAULIC FRICTION LOSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.17 ENDURANCE TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
2.18 VALVE IMPAIRMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.19 AUTOMATIC DRAIN VALVE FOR ALARM LINES . . . . . . . . . . . . . . . . 11
2.20 CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SECTION 4 MARKING
4.1 METHOD OF MARKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.2 INFORMATION REQUIRED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.3 LETTERING DETAILS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
STANDARDS AUSTRALIA
Australian Standard
Fire sprinkler systems
S E C T I O N 1 S CO P E A N D G E NE R A L
1.1 SCOPE This Standard specifies the construction, performance and testing
requirements for deluge valves used in deluge and pre-action fire sprinkler systems.
This is a free 6 page sample. Access the full version at http://infostore.saiglobal.com.
1.3 DEEMED TO SATISFY Any deluge or pre-action valve that has been listed and
approved by an internationally recognized test and approval body such as—
(a) Factory Mutual (FM);
(b) Underwriters Laboratories (UL);
(c) Loss Prevention Council (LPC);
or has been listed by Scientific Services Laboratory (SSL) in the —
SSL Register of Accredited Products
Fire Protection Equipment
shall be deemed to satisfy the requirements of this Standard.
COPYRIGHT
This is a free preview. Purchase the entire publication at the link below: