You are on page 1of 30

Cables according to

International Approvals

F1

Cables according to International Approvals


The installation of cables and wires according to
overseas standards are getting more and
important for the machine and plant industries.
HELUKABEL knows this problem from his
customers and delivers since long time single core
and multicore cables according to the following
standards. Due to our extensive stock capacity, we
are in a position to cover your requirements quick
and correctly.
Please enquire to our sales department.
UL
Underwriters Laboratories Inc.
AWM
Appliance Wiring Material
MTW
Machine Tool Wire
CEI
Comitato Elettrotecnico Italiano
CSA
Canadian Standard Association
SEV
Schweizerischer Elektrotechnischer Verein
USASI
USA Standard Institute
CNOMO Comit De Normalisation Des Moyens
De Production
GOST
GOST-R Certification
CCC
China Compulsory Certification

F2

Contents
Description

Page

UL-Style 1007, CSA TR 64 ,

PVC single cores, 80C, 300V

............................................................................................................................

F4

UL-Style 1569, CSA TR 64 ,

PVC single cores, 105C, 300V

...........................................................................................................................

F5

UL-Style 1015 ,
THREENORM ,
FIVENORM ,

PVC single core, 600V

............................................................................................................................................

F6

................................................................................................................

F7

PVC single core, UL-Style 1011 and CSA 600V

HAR-UL-CSA-AWM-MTW, PVC single core, UL-Style 1015/UL-Standard 1063, 600V, 105C

THHN/THWN ,

90C, 600V, UL listed, PVC + nylon single core

.............................................................

F 11
F 12

HELUTHERM 145 ,

300V, flexible single core, electron beam cross-linked, halogen-free

......................................................................................

HELUTHERM 145 ,

600V, flexible single core, eletron beam cross-linked, halogen-free

.......................................................................................

F 13

.................................................................................................................................

F 14

.......................................................................................................................

F 15

......................................................................................................

F 16

....................................................................................................

F 18

Command Cable UL (LiYY) ,

Style 2464/300 V, (80C)

Command Cable UL (LiYY) ,

600V, Style 2516/600 V, (105C)

Command Cable UL (LiYCY) ,

Style 2464, 300V, 80C, EMC-preferred type

Command Cable UL (LiYCY) ,

Style 2516/600 V, 105C, EMC-preferred type

Command Cable UL (LiYY-TP) ,

Style 2464/300V, 80C

Command Cable UL (LiYCY-TP) ,


PVC Single Core ,
C.N.O.M.O ,

F 19

................................................................................................

F 21

...........................................................................................................................

F 23

Types SJO und SO

.............................................................................................................................................................

F 24

empty ......................................................................................................................................................................

F 25

to CEI 20-22 II

FROR CEI 20-22 II ,

..............................................................................................................................

Style 2464/300 V, 80C, EMC-preferred type

Rubber / Neoprene Control Cable ,

F9

..........................................................................................................................

Type N0VV5-F according to NFC 32-207

JZ 604 TC TRAY CABLE ,

......................................................................................................................................

F 26

................................................................................................................................

F 27

PVC power cable, 90C, 600V

JZ 604-FCY TC TRAY CABLE ,

PVC power cable, screened, 90C, 600V, EMC-preferred type

................................................................................

F 29

JZ 604-YCY TC TRAY CABLE ,

PVC power cable, screened, 90C, 600V, EMC-preferred type

................................................................................

F 30

F3

UL-Style 1007, CSA TR 64

Technical data

PVC-insulated jumper wire to UL-Style and


CSA-AWM
Temperature range
flexible -5C bis +80C
fixed installation -30C bis +80C
CSA-AWM I A/B or TR 64 +90C
Nominal voltage 300 V
Test voltage 2000 V
Test voltage (Spark test)
AWG 26-20 = 4 kV
AWG 10-18 = 5 kV
Bending radius
once ca. 5 cable
multiple ca. 10 cable

PVC single cores, 80C, 300V

Cable construction

Stranded copper conductor, tinned to


UL-Std. 785 section G
PVC-core insulation according to
UL-Std. 1581 class 43 Tab. 50.182, heat and
damp resistant

Properties

Conditionally resistant to
Oils
Solvents
Acids
Lyes
PVC self-extinguishing and flame retardant,
test method to UL VW-1/CSA FT1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

Please complete the above part number


for the colour required, using the following
table:
00 = green
01 = black
02 = blue
03 = brown
04 = red
05 = white
06 = grey
07 = violet
08 = yellow
09 = orange
10 = transparent
11 = pink
12 = beige
13 = green-yellow
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Due to design the constructional
alternations may the possible.

Application

For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks.
Connecting wires in machines laid in protective tubes and flexible pipes and also for motors and transformators.
AWM = Appliance Wiring Material
For internal wirings for electrical equipment and control apparatus e.g. electronic assembly components.
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Canada)
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No. Crosssection
ca. mm
635xx
0,13
620xx
0,21
621xx
0,33
622xx
0,52
623xx
0,82

AWG-no.
26
24
22
20
18

Outer
ca. mm
1,3
1,4
1,6
1,9
2,2

Cop.
weight
kg / km
1,6
2,3
3,4
5,3
8,2

Weight
ca. kg / km
3,2
4,3
6,0
8,5
12,5

Part No. Crosssection


ca. mm
624xx
1,32
636xx
2,08
637xx
3,31
638xx
5,26

AWG-no.
16
14
12
10

Outer
ca. mm
2,5
3,0
3,9
4,1

Cop.
weight
kg / km
13,0
20,0
33,0
51,6

Weight
ca. kg / km
18,5
29,0
40,0
61,0

Dimensions and specifications may be changed without prior notice.

F4

UL-Style 1569, CSA TR 64

Technical data

PVC-insulated jumper wire to UL-Style and


CSA-AWM
Temperature range
flexible -5C bis +105C
fixed installation -30C bis +105C
CSA-AWM I A/B or TR 64 +90C
Nominal voltage 300 V
Test voltage 2000 V
Test voltage (Spark test)
AWG 26-20 = 4 kV
AWG 10-18 = 5 kV
Bending radius
once ca. 5 cable
multiple ca. 10 cable

PVC single cores, 105C, 300V

Cable construction

Stranded copper conductor, tinned to


UL-Std. 785 section G
PVC-core insulation according to
UL-Std. 1581 class 43 Tab. 50.182, heat and
damp resistant

Properties

Conditionally resistant to
Oils
Solvents
Acids
Lyes
PVC self-extinguishing and flame retardant,
test method to UL VW-1/CSA FT1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

Please complete the above part number


for the colour required, using the following
table:
00 = green
01 = black
02 = blue
03 = brown
04 = red
05 = white
06 = grey
07 = violet
08 = yellow
09 = orange
10 = transparent
11 = pink
12 = beige
13 = green-yellow
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Due to design the constructional
alternations may the possible.

Application

For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks.
Connecting wires in machines laid in protective tubes and flexible pipes and also for motors and transformators.
AWM = Appliance Wiring Material
For internal wirings for electrical equipment and control apparatus e.g. electronic assembly components.
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Canada)
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No. Crosssection
ca. mm
660xx
0,13
661xx
0,21
662xx
0,33
663xx
0,52
664xx
0,82

AWG-no.
26
24
22
20
18

Outer
ca. mm
1,3
1,4
1,6
1,9
2,2

Cop.
weight
kg / km
1,6
2,3
3,4
5,3
8,2

Weight
ca. kg / km

Dimensions and specifications may be changed without prior notice.

F5

3,2
4,3
6,0
8,5
12,5

Part No. Crosssection


ca. mm
665xx
1,32
666xx
2,08
667xx
3,31
668xx
5,26

AWG-no.
16
14
12
10

Outer
ca. mm
2,5
3,0
3,9
4,1

Cop.
weight
kg / km
13,0
20,0
33,0
51,6

Weight
ca. kg / km
18,5
29,0
40,0
61,0

UL-Style 1015

PVC single core, 600V

Technical data

PVC-insulated jumper wire as per UL AWM


Style 1015/MTW and CSA-AWM/TEW as per
UL-Style 1015 and CSA-TEW
Temperature range
flexible -5C to +105C
fixed installation -30C to +105C
Temperature at conductor
max. UL and CSA: +105C
Nominal voltage 600 V
Test voltage (Spark test)
AWG 24: 4 kV
AWG 22 and 20: 5 kV
AWG 18 to 10: 6 kV
AWG 8: 7,5 kV
UL-type AWM + MTW 105C 600 V
CSA-type AWM + TEW 105C 600 V
Bending radius
once ca. 5 cable
multiple ca. 10 cable

Cable construction

Stranded copper conductor, tinned or plain


AWG-sizes as per table below
PVC-core insulation according to
UL-Standard 1581, class 43 and CSA-C22.2
No. 210 UL VW-1 and CSA FT1, heat and
damp resistant

Properties

Conditionally resistant to
Oils
Solvents
Acids
Lyes
PVC self-extinguishing and flame
retardant, test method to UL VW-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

Please complete the above part number


for the colour required, using the following
table:
00 = green / 01 = black /
02 = blue / 03 = brown /
04 = red / 05 = white /
06 = grey / 07 = violet /
08 = yellow / 09 = orange /
10 = transparent / 11 = pink /
12 = beige / 13 = green-yellow /
14 = blue/white / 15 = dark blue
27 = white/blue (supply up to AWG 8)

Application

For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks. Connecting wires in
machines laid in predective tubes and flexible pipes and also for motors and transformators.
UL bzw. CSA:
AWM = Appliance Wiring Material
For internal wirings for electrical equipment and control apparatus e. g. electronic assembly components. UL-MTW: Machine Tool-Wires
CSA-TEW: Equipment/Lead Wires
MTW = Machine Tool Wire
For the electronical installation of machine tools and the relative control
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Kanada)
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No. Crosssection
ca. mm
601xx
0,21
602xx
0,33
603xx
0,52
604xx
0,81
605xx
1,31
606xx
2,08
607xx
3,32
608xx
5,26
609xx
8,35
610xx
13,29
611xx
21,14
612xx
26,65

AWG-no.
24
22
20
18
16
14
12
10
8
6
4
3

Outer
ca. mm
2,2
2,4
2,5
2,8
3,1
3,5
4,0
4,6
6,5
8,0
9,5
10,4

Cop.
weight
kg / km
2,3
3,2
5,0
7,9
12,6
20,7
33,0
51,6
80,6
125,0
201,0
253,0

Weight
ca. kg / km
8,0
10,0
12,0
16,0
22,0
31,0
45,0
65,0
110,0
175,0
260,0
340,0

Part No. Crosssection


ca. mm
613xx
33,61
614xx
42,38
615xx
53,47
616xx
67,4
617xx
84,97
618xx
107,17
62501
127
62601
152
62701
178
62801
203
62901
254

AWG-no.
2
1
1/0
2/0
3/0
4/0
250 kcmil
300 kcmil
350 kcmil
400 kcmil
500 kcmil

Outer
ca. mm
11,3
13,3
13,6
15,5
17,5
19,0
21,2
22,4
25,3
26,0
28,0

Cop.
weight
kg / km
317,0
399,0
500,0
631,0
792,0
996,0
1178,0
1410,0
1645,0
1902,0
2345,0

Weight
ca. kg / km
380,0
500,0
615,0
750,0
900,0
1070,0
1280,0
1518,0
1756,0
2002,0
2475,0

Dimensions and specifications may be changed without prior notice.

F6

THREENORM

PVC single core, UL-Style 1011 and CSA 600V

Technical data

PVC-single cores according to DIN VDE 0281


part 3 and HD 21.3 S3 UL-Style 1011 and
CSA, CSA-AWM I/A/B
Temperature range
H05 V-K/H07 V-K
flexing +5C to +70C
fixed installation -10C to +70C
UL/CSA +80C
Nominal voltage
H05 V-K U0/U 300/500 V (?1 mm)
H07 V-K U0/U 450/750 V (1,5 mm)
UL/CSA 600 V AC
Test voltage
H05 V-K/H07 V-K 2000 V
Spark Test
AWG 20: 5 kV
>AWG 20: 6 kV
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
for permanent bending
ca. 10-15 core

Cable construction

Bare copper fine wire stranded to


DIN VDE 0295 cl. 5, BS 6360 cl. 5, HD 383
and IEC 60228 cl. 5
UL-Subject 758 Section G resp.ASTM B 174
PVC core insulation TI1 to DIN VDE 0281
part 1 and UL-Std. 1581, class 43,
CSA-C 22.2 No. 210 Tab. 12 class H
Core colours to DIN VDE 0293

Properties

PVC self-extinguishing and flame retardant


according to DIN VDE 0482 part 265-2-1/
EN 50265-2-1/ IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
UL-VW1 CSA FT1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

Tinned conductor on request.


AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
The cross-sections 0,5 mm, 0,75 mm and
1,0 mm are according to H05 V-K,
the cross-sections 1,5 up to 120 mm
according to H07 V-K.

Application

Three norms approved connecting jumper wire primarily designed for exportes, used in machine tools. This wire is used for internal wiring
of switchboards and electrical equipment. The approbation of HAR-UL-CSA AWM make possible an economical storekeeping and simplification
of parts list.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
H05 V-K/mm
Cross-sec.
mm
/ AWG-no.
ca. RAL
Part No.
0,5 / 20
Part No.
0,75 / 19
Part No.
1 / 18

Outer
ca. mm

2.5
2.6
2.8

H07 V-K/mm
Cross-sec.
mm
/ AWG-no.
ca. RAL
Part No.
1,5 / 16
Part No.
2,5 / 14
Part No.
4 / 12
Part No.
6 / 10
Part No.
10 / 8
Part No.
16 / 6
Part No.
25 / 4
Part No.
35 / 2

Outer
ca. mm

3.0
3.6
4.1
4.8
6.4
8.1
9.6
10.8

Cop.
black
weight
kg / km
9005
63815
4,8
63831
7,2
63847
9,6

blue

brown

red

white

grey

vio

pink

og

green

ye

gn-ye

2-col.

dk-bu

trans

o.col.

5015
63817

8003
63818

3000
63819

1013
63820

7000
63821

4005
63822

3015
63824

2003
63828

6018
63825

1021
63823

63816

63830

5010
63827

63826

63829

63833

63834

63835

63836

63837

63838

63840

63844

63841

63839

63832

63846

63843

63842

63845

63849

63850

63851

63852

63853

63854

63856

63860

63857

63855

63848

63862

63859

63858

63861

Cop.
black
weight
kg / km
9005
63863
14,4
63879
24,0
63895
38,0
63911
58,0
63927
96,0
63943
154,0
63959
240,0
63975
336,0

blue

brown

red

white

grey

vio

pink

og

green

ye

gn-ye

2-col.

dk-bu

trans

o.col.

5015
63865

8003
63866

3000
63867

1013
63868

7000
63869

4005
63870

3015
63872

2003
63876

6018
63873

1021
63871

63864

63878

5010
63875

63874

63877

63881

63882

63883

63884

63885

63886

63888

63892

63889

63887

63880

63894

63891

63890

63893

63897

63898

63899

63900

63901

63902

63904

63908

63905

63903

63896

63910

63907

63906

63909

63913

63914

63915

63916

63917

63918

63920

63924

63921

63919

63912

63926

63923

63922

63925

63929

63930

63931

63932

63933

63934

63936

63940

63937

63935

63928

63942

63939

63938

63941

63945

63946

63947

63948

63949

63950

63952

63956

63953

63951

63944

63958

63955

63954

63957

63961

63962

63963

63964

63965

63966

63968

63972

63969

63967

63960

63974

63971

63970

63973

63977

63978

63979

63980

63981

63982

63984

63988

63985

63983

63976

63990

63987

63986

63989

Dimensions and specifications may be changed without prior notice.

F7

Continuation

THREENORM
H07 V-K/mm
Cross-sec.
mm
/ AWG-no.
ca. RAL
Part No.
50 / 1
Part No.
70 / 2/0
Part No.
95 / 3/0
Part No.
120 / 4/0
Part No.
150 / 300 kcmil

Outer
ca. mm

13.6
15.2
16.8
19.5
22.2

Cop.
black
weight
kg / km
9005
63991
480,0
64007
672,0
64023
912,0
64039
1152,0
64055
1440,0

PVC single core, UL-Style 1011 and CSA 600V

blue

brown

red

white

grey

vio

pink

og

green

ye

gn-ye

2-col.

dk-bu

trans

o.col.

5015
63993

8003
63994

3000
63995

1013
63996

7000
63997

4005
63998

3015
64000

2003
64004

6018
64001

1021
63999

63992

64006

5010
64003

64002

64005

64009

64010

64011

64012

64013

64014

64016

64020

64017

64015

64008

64022

64019

64018

64021

64025

64026

64027

64028

64029

64030

64032

64036

64033

64031

64024

64038

64035

64034

64037

64041

64042

64043

64044

64045

64046

64048

64052

64049

64047

64040

64054

64051

64050

64053

64057

64058

64059

64060

64061

64062

64064

64068

64065

64063

64056

64070

64067

64066

64069

Dimensions and specifications may be changed without prior notice.

F8

FIVENORM

HAR-UL-CSA-AWM-MTW, PVC single core,


UL-Style 1015/UL-Standard 1063, 600V, 105C

Technical data

PVC-single cores according to DIN VDE 0281


part 7 and HD 21.7 S2, UL-Std. 1063,
UL-Style 1015 and CSA-TEW and
CSA-AWM I/A/B
Temperature range
H05 V2-K/H07 V2-K
flexing +5C to +90C
fixed installation -10C to +105C
UL (AWM) +105C
UL (MTW) +90C
CSA (TEW) +105C
Nominal voltage
H05 V2-K: U0/U 300/500 V (up to 1 mm)
H07 V2-K: U0/U 450/750 V (1,5 mm)
UL/CSA 600 V AC, 750 V DC
Test voltage
H05 V2-K/H07 V2-K 2000 V
Spark Test
AWG 20: 5 kV
>AWG 20: 6 kV
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
for permanent bending
ca. 10-15 core

Cable construction

Bare copper fine wire stranded to


DIN VDE 0295 cl. 5, BS 6360 cl. 5, HD 383
and IEC 60228 cl. 5 and UL-Subject 758
Section G
PVC core insulation TI3 to DIN VDE 0281
part 1 and UL-Std. 1581, class 43,
CSA-C 22.2 No. 210 Tab. 12 class H
Core colours to DIN VDE 0293
2-colour combination - Part No. on request

Properties

PVC self-extinguishing and flameretardant


according to DIN VDE 0482 part 265-2-1/
EN 50265-2-1/ IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B), CSA
FT1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

Tinned conductor on request.


The cross-sections 0,5 mm, 0,75 mm and
1,0 mm are according to H05 V2-K, the
cross-sections 1,5 up to 35 mm according
to H07 V2-K, the cross-sections >35 mm
are identified as H07 V-K.
Cross-sections up to 35 mm is according
to DIN VDE 0281 part 5. Due to this
cross-section >35 mm is the type but with
an increased heat-resistant PVC-compound.

Application

Five norms approved connecting jumper wire primarily designed for exportes, used in machine tools. The approbation of HAR, UL-AWM,
UL-MTW, CSA-AWM, CSA-Equipment-wire make possible an economical storekeeping and simplification of parts list.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
H05 V2-K/mm
Cross-sec.
mm
/ AWG-no.
ca. RAL
Part No.
0,5 / 20
Part No.
0,75 / 19
Part No.
1 / 18

Outer
ca. mm

2.5
2.6
2.8

H07 V2-K/mm
Cross-sec.
mm
/ AWG-no.
ca. RAL
Part No.
1,5 / 16
Part No.
2,5 / 14
Part No.
4 / 12
Part No.
6 / 10
Part No.
10 / 8
Part No.
16 / 6
Part No.
25 / 4
Part No.
35 / 2

Outer
ca. mm

3.0
3.6
4.1
4.8
6.4
8.1
9.6
10.8

Cop.
black
weight
kg / km
9005
64075
4,8
64091
7,2
64107
9,6

blue

brown

red

white

grey

vio

pink

og

green

ye

gn-ye

2-col.

dk-bu

trans

o.col.

5015
64077

8003
64078

3000
64079

1013
64080

7000
64081

4005
64082

3015
64084

2003
64088

6018
64085

1021
64083

64076

o. r.

5010
64087

64086

64089

64093

64094

64095

64096

64097

64098

64100

64104

64101

64099

64092

o. r.

64103

64102

64105

64109

64110

64111

64112

64113

64114

64116

64120

64117

64115

64108

o. r.

64119

64118

64121

Cop.
black
weight
kg / km
9005
64123
14,4
64139
24,0
64155
38,0
64171
58,0
64187
96,0
64203
154,0
64219
240,0
64235
336,0

blue

brown

red

white

grey

vio

pink

og

green

ye

gn-ye

2-col.

dk-bu

trans

o.col.

5015
64125

8003
64126

3000
64127

1013
64128

7000
64129

4005
64130

3015
64132

2003
64136

6018
64133

1021
64131

64124

o. r.

5010
64135

64134

64137

64141

64142

64143

64144

64145

64146

64148

64152

64149

64147

64140

o. r.

64151

64150

64153

64157

64158

64159

64160

64161

64162

64164

64168

64165

64163

64156

o. r.

64167

64166

64169

64173

64174

64175

64176

64177

64178

64180

64184

64181

64179

64172

o. r.

64183

64182

64185

64189

64190

64191

64192

64193

64194

64196

64200

64197

64195

64188

o. r.

64199

64198

64201

64205

64206

64207

64208

64209

64210

64212

64216

64213

64211

64204

o. r.

64215

64214

64217

64221

64222

64223

64224

64225

64226

64228

64232

64229

64227

64220

o. r.

64231

64230

64233

64237

64238

64239

64240

64241

64242

64244

64248

64245

64243

64236

o. r.

64247

64246

64249

Dimensions and specifications may be changed without prior notice.

F9

Continuation

FIVENORM

HAR-UL-CSA-AWM-MTW, PVC single core,


UL-Style 1015/UL-Standard 1063, 600V, 105C

H07 V-K/mm

Cross-sec.
mm
/ AWG-no.
ca. RAL
Part No.
50 / 1
Part No.
70 / 2/0
Part No.
95 / 3/0
Part No.
120 / 4/0
Part No.
150 / 300 kcmil

Outer
ca. mm

13.6
15.2
16.8
19.5
22.2

Cop.
black
weight
kg / km
9005
64251
480,0
64267
672,0
64283
912,0
64299
1152,0
64315
1440,0

blue

brown

red

white

grey

vio

pink

og

green

ye

gn-ye

2-col.

dk-bu

trans

o.col.

5015
64253

8003
64254

3000
64255

1013
64256

7000
64257

4005
64258

3015
64260

2003
64264

6018
64261

1021
64259

64252

o. r.

5010
64263

64262

64265

64269

64270

64271

64272

64273

64274

64276

64280

64277

64275

64268

o. r.

64279

64278

64281

64285

64286

64287

64288

64289

64290

64292

64296

64293

64291

64284

o. r.

64295

64294

64297

64301

64302

64303

64304

64305

64306

64308

64312

64309

64307

64300

o. r.

64311

64310

64313

64317

64318

64319

64320

64321

64322

64324

64328

64325

64323

64316

o. r.

64327

64326

64329

Dimensions and specifications may be changed without prior notice.

F 10

THHN/THWN

90C, 600V, UL listed, PVC + nylon single core

Technical data

PVC + Nylon insulated single cores as per


UL-Styles und NEC standard
Temperature range as per Styles
THHN: 90C dry - NEC standard
THWN: 75C wet - NEC standard
AWM: UL-Styles 1316 to 1321
105C dry
80C in oil
AWM: UL-Styles 1452, 1453
90C dry
80C in oil
1000 V
MTW: UL-Styles 1408 to 1414
90C dry
80C in oil
600 V
Nominal voltage 600 V
Test voltage (Spark test)
AWG 14 to AWG 10 = 7,5 kV
AWG 8 to AWG 2/0 = 10 kV
AWG 3/0 to AWG 4/0 = 12,5 kV
kcmil 250 to kcmil 500 = 15 kV
kcmil 600 to kcmil 1000 = 17,5 kV

Cable construction

Bare copper conductor, AWG-sizes as per


given table below and ASTM B-3 and ASTM
B-8
Core insulation of PVC+Nylon-outer-sheath
Cores colour coded, colour identification
see below
Surface of jacket printed with markings:
14 to 1000 MCM THHN (stranded) - (size)
AWG Type MTW OR THHN OR THWN 600 V
OR GASOLINE AND OIL RESTSTANT II (UL) OR
AWM W-51554
14 to 10 AWG THHN (solid) - (size)
AWG TYPE THHN OR THWN 600 V OR
GASOLINE AND OIL RESISTANT II (UL) OR AWM

Properties

Resistant against
Oils
Gasoline
Water
Acids
Ozone
Lyes
Sunlight
Abrasion

Note

1 kcmil = 1000 circ mils = 0,5067 mm.


Please complete the above part number
for the colour required, using the following
code:
0 = green
1 = black
2 = blue
3 = brown
4 = red
5 = white
6 = grey
7 = yellow
8 = orange
9 = pink

Application

As flexible connecting cable in machines, switch and distribution cabinets, cable assemblies and for fixed indoor installation, in tubes and in
cable conduits.
AWM = Appliance Wiring Material / For internal wrings for electrical equipment and control apparatus e.g. radio and televisions, electronic
assembly component.
MTW = Machine Tool Wire / For the electronical installation of machine tools and the relative control.
THW = Thermoplastic PVC-insulated building wire, Heat resistant 75C, for Wet and dry locations, flame retardant.
THHN = Thermoplastic PVC-insulated building wire, Nylon jacketed, 90C 600 V, for dry and damp locations.
UL = Underwriters Laboratories Inc. (USA)
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No.
6320x
6321x
6322x
6323x
6324x
6325x
6326x
6327x
6328x
6329x
6330x
6331x
6332x
Part No.
63331
63341
63351
63361
63371
63381
63391
63401

Cross-sec.
mm

AWG-no.

2,08
3,32
5,26
8,35
13,39
21,14
26,65
33,61
42,38
53,47
67,4
84,97
107,17

14
12
10
8
6
4
3
2
1
1/0
2/0
3/0
4/0

Cross-sec.
mm

AWG-no.

AWG
size

250 kcmil
300 kcmil
350 kcmil
400 kcmil
500 kcmil
600 kcmil
750 kcmil
1000 kcmil

0,0822
0,09
0,0973
0,104
0,1162
0,0992
0,1109
0,128

127
152
178
203
254
304
380
507

AWG
size
0,0147
0,0185
0,0234
0,0295
0,0378
0,0469
0,053
0,0591
0,0664
0,0745
0,0837
0,094
0,1055

Dimensions and specifications may be changed without prior notice.

F 11

Cond.
make-up
n x wire
19 x 0,38
19 x 0,48
19 x 0,6
19 x 0,75
19 x 0,96
19 x 1,19
19 x 1,336
19 x 1,5
19 x 1,686
19 x 1,89
19 x 2,126
19 x 2,387
19 x 2,68

Outer
ca. mm

Cond.
make-up
n x wire
37 x 2,088
37 x 2,286
37 x 2,47
37 x 2,7
37 x 2,95
61 x 2,52
61 x 2,82
61 x 3,25

Outer
ca. mm

3,0
3,4
4,3
5,5
6,6
8,4
9,1
10,0
11,4
12,4
13,7
15,0
16,5

18,3
19,6
21,1
22,4
24,1
26,8
29,4
33,3

Cop.
weight
kg / km
20,7
33,0
51,6
80,6
125,0
201,0
253,0
317,0
399,0
500,0
631,0
792,0
996,0

Weight
ca. kg / km

Cop.
weight
kg / km
1178,0
1410,0
1645,0
1902,0
2345,0
2920,0
3658,0
4858,0

Weight
ca. kg / km

25,0
37,0
60,0
95,0
143,0
229,0
282,0
349,0
449,0
557,0
691,0
861,0
1069,0

1277,0
1515,0
1753,0
1998,0
2466,0
3000,0
3713,0
4796,0

HELUTHERM 145

300V, flexible single core, electron beam

cross-linked, halogen-free

Technical data

Halogen-free single cores with increased


heat resistance according to
UL Style 3266
CSA CL 1252
Temperature range fixed
flexing -35C to +120C
fixed installation -45C to +145C
in short circuit +250C
Nominal voltage U0/U 300/300 V
Test voltage 2000 V
Minimum bending radius
flexing 12,5x cable
fixed installation 4x cable
Caloric load values
see Technical Informations
Power ratings table
see Technical Informations

Cable construction

Tinned Cu wires, according to AWG-sizes


Conductor make-up:
AWG 24 to AWG 14 = 19-wires
AWG 12 = 65-wires
AWG 10 = 105-wires
Core insulation of polyolefin-copolymer,
electron beam cross-linked, flame
retardant, halogen-free
Core colours see table below
Tests
Flame test to DIN VDE 0482 Teil 266-2/
HD 405.3, BS 4066 part 3/ EN 50266-2/
IEC 60332-3 (equivalent DIN VDE 0472
part 804 test method C)
Corrosiveness of combustion gases
according to DIN VDE 0482 part 267/
EN 50267-2-2/ IEC 60754-2 (equivalent
DIN VDE 0472 part 813)
Halogen-free accordingto DIN VDE 0482
part 267/ EN 50267-2-1/ IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density to VDE 0482 part 268-1
u. 2, test method C, IEC 61034-1/61034-2,
HD 606 and BS 7622 part 1 and 2
(equivalent DIN VDE 0472 part 816)

Properties

Halogen-free, no liberation of corrosive or


toxic vapours, in that way this helps saving
valuable time when trying to evacuate a
building in a diciplined manner and
prevents unnecessary loss of life
Lower propagation of fire
Low development of smoke and fumes
Good abrasion and notch resistance
Good resistance to oils and weathering
Resistant to UV radiation and ozone
Resistant to soldering temperatures
Thermal class B
These single-core cables are resistant to
melting, even when in contact with a
soldering iron at temperatures of between
300C and 380C, because of the
electron-beam cross-linking for the
insulation material
Due to the high temperature profile the
cross-section of conductor can under
certain circumstances be reduced, hereby
enabling a saving in space requirement and
weight
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application

These temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching
systems and distributors in equipment and plant and machinery, suitable for installation on, in and beneath plaster, in closed installation
ducts, as well as for traffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks.
For a protected installation, these cables may be used at a nominal voltage of up to 1000 V alternating current or a direct current up to
750 V when earthed. The maximum operating d.c. voltage used in rail vehicles shall not exceed 900 V when earthed. These halogen-free
single core cables are characterised by their amazingly hight long-time resistance to temperature and feature among the leading halogen-free.
Flame resistant products in the world.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
AWG-no.
ca. RAL
Part No.
24
Part No.
22
Part No.
20
Part No.
18
Part No.
16
Part No.
14
Part No.
12
Part No.
10

Outer Cop.
Weight
ca. mm weight ca. kg /
kg / km km
black
9005
61817
1.5
2,3
4,0
61831
1.6
3,2
6,0
61845
1.9
5,0
9,0
61859
2.1
7,9
12,0
61873
2.4
12,6
16,0
61887
2.9
20,7
27,0
61901
3.3
33,0
36,0
61915
4.1
51,6
58,0

brown
8003
61819

red
3000
61820

white
1013
61821

grey
7000
61822

vio
4005
61823

green
6018
61826

beige
1001
61828

pink
3015
61827

lt-bu
5015
61818

og
2003
61825

ye
1021
61824

gn-ye
2-col.
6028/1021
61816
61829

61833

61834

61835

61836

61837

61840

61842

61841

61832

61839

61838

61830

61843

61847

61848

61849

61850

61851

61854

61856

61855

61846

61853

61852

61844

61857

61861

61862

61863

61864

61865

61868

61870

61869

61860

61867

61866

61858

61871

61875

61876

61877

61878

61879

61882

61884

61883

61874

61881

61880

61872

61885

61889

61890

61891

61892

61893

61896

61898

61897

61888

61895

61894

61886

61899

61903

61904

61905

61906

61907

61910

61912

61911

61902

61909

61908

61900

61913

61917

61918

61919

61920

61921

61924

61926

61925

61916

61923

61922

61914

61927

Dimensions and specifications may be changed without prior notice.

F 12

HELUTHERM 145 600V, flexible single core, eletron beam cross-linked,

halogen-free

Technical data

Halogen-free single cores with increased


heat resistance according to
UL Style 3271
CSA CL 1251
Temperature range
flexing -35C to +120C
fixed installation -45C to +145C
in short circuit +250C
Nominal voltage U 600 V
Test voltage 3500 V
Minimum bending radius
flexing 12,5x cable
fixed installation 4x cable
Caloric load values
see Technical Informations
Power ratings table
see Technical Informations

Cable construction

Tinned Cu wires, according to DIN VDE 0295


cl. 5, BS 6360 cl. 5 and IEC 60228 cl. 5
Core insulation of polyolefin-copolymer,
electron beam cross-linked, flame
retardant, halogen-free
Core colours see table below
Tests
Flame test to DIN VDE 0482 Teil 266-2/
HD 405.3, BS 4066 part 3/ EN 50266-2/
IEC 60332-3 (equivalent DIN VDE 0472
part 804 test method C)
Corrosiveness of combustion gases
according to DIN VDE 0482 part 267/
EN 50267-2-2/ IEC 60754-2 (equivalent
DIN VDE 0472 part 813)
Halogen-free accordingto DIN VDE 0482
part 267/ EN 50267-2-1/ IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density to VDE 0482 part 268-1
u. 2, test method C, IEC 61034-1/61034-2,
HD 606 and BS 7622 part 1 and 2
(equivalent DIN VDE 0472 part 816)

Properties

Halogen-free, no liberation of corrosive or


toxic vapours, in that way this helps saving
valuable time when trying to evacuate a
building in a diciplined manner and
prevents unnecessary loss of life
Lower propagation of fire
Low development of smoke and fumes
Good abrasion and notch resistance
Good resistance to oils and weathering
Resistant to UV radiation and ozone
Resistant to soldering temperatures
Resistant to melting, even when in contact
with a soldering iron at temperatures of
between 300C and 380C, because of the
electron-beam cross-linking for the
insulation material
Due to the high temperature profile the
cross-section of conductor can under
certain circumstances be reduced, hereby
enabling a saving in space requirement and
weight
The materials in manufacture are
cadmium-free +contain no silicone +free
from substances harmful to the wetting
properties of lacquers

Application

These temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching
systems and distributors in equipment and plant and machinery, suitable for installation on, in and beneath plaster, in closed installation
ducts, as well as for traffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks.
For a protected installation, these cables may be used at a nominal voltage of up to 1000 V alternating current or a direct current up to
750 V when earthed. The maximum operating d.c. voltage used in rail vehicles shall not exceed 900 V when earthed.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Crosssection
mm
ca. RAL
Part No.
0,25
Part No.
0,5
Part No.
0,75
Part No.
1,0
Part No.
1,5
Part No.
2,5
Part No.
4,0
Part No.
6,0
Part No.
10,0
Part No.
16,0
Part No.
25,0
Part No.
35,0
Part No.
50,0

Outer Cop.
Weight AWG-No.
ca. mm weight ca. kg /
kg / km km
brown
black
8003
9005
59473
59475
2.3
2,4
7,0
24
59487
59489
2.6
4,8
11,0
20
59501
59503
2.8
7,2
14,0
18
59515
59517
2.9
9,6
17,0
17
59529
59531
3.2
14,4
22,0
16
59543
59545
3.7
24,0
33,0
14
59557
59559
4.2
38,4
53,0
12
59571
59573
5.6
57,6
78,0
10
59585
59587
7.5
96,0
136,0
8
59599
59601
8.5
154,0
203,0
6
59613
59615
10.4
240,0
300,0
4
59627
59629
11.5
336,0
405,0
2
59641
59643
14.4
480,0
580,0
1

red
3000
59476

white
1013
59477

grey
7000
59478

vio
4005
59479

green
6018
59482

beige
1001
59484

pink
3015
59483

lt-bu
5015
59474

og
2003
59481

ye
1021
59480

gn-ye
2-col.
6028/1021
59472
59485

59490

59491

59492

59493

59496

59498

59497

59488

59495

59494

59486

59499

59504

59505

59506

59507

59510

59512

59511

59502

59509

59508

59500

59513

59518

59519

59520

59521

59524

59526

59525

59516

59523

59522

59514

59527

59532

59533

59534

59535

59538

59540

59539

59530

59537

59536

59528

59541

59546

59547

59548

59549

59552

59554

59553

59544

59551

59550

59542

59555

59560

59561

59562

59563

59566

59568

59567

59558

59565

59564

59556

59569

59574

59575

59576

59577

59580

59582

59581

59572

59579

59578

59570

59583

59588

59589

59590

59591

59594

59596

59595

59586

59593

59592

59584

59597

59602

59603

59604

59605

59608

59610

59609

59600

59607

59606

59598

59611

59616

59617

59618

59619

59622

59624

59623

59614

59621

59620

59612

59625

59630

59631

59632

59633

59636

59638

59637

59628

59635

59634

59626

59639

59644

59645

59646

59647

59650

59652

59651

59642

59649

59648

59640

59653

Dimensions and specifications may be changed without prior notice.

F 13

Command Cable UL (LiYY)

Technical data

Special PVC command cable, approved to


UL-Style 2464, cores according
AWG 26-20 to UL-Style 1061/1729
AWG 18-16 to UL-Style 1007/1569
Temperature range
-20C to +80C
Nominal voltage 300 V
Test voltage 1500 V
Breakdown voltage
min. 3000 V
Minimum bending radius
flexing approx. 15x cable

Cable construction

Style 2464/300 V, (80C)

Tinned copper, fine wire conductors


AWG 26-20, gem ASTM-B 174-95
class J-M,
AWG 18-16 gem ASTM-B 286
Conductor make-up to:
0,14 mm = 7x0,162 mm
0,22 mm = 7x0,202 mm
0,34 mm = 7x0,254 mm
0,56 mm = 7x0,32 mm
0,82 mm = 19x0,235 mm
1,30 mm = 19x0,31 mm
Special PVC core insulation class 43,
semirigid to UL-Std. 1581 table 50.182 and
50.183
Colour coded to DIN 47100 or international
colour code
Cores stranded in layers with optimal
lay-length
Special PVC outer jacket class 43 to
UL-Std. 1581 table 50.182
Outer jacket colour
black (international colour code)
grey (DIN 47100 / preferred type for stock)

Properties

PVC flame retardant according to UL VW-1


Conditionally resistant to
Oil
Solvents
Acids
Lyes
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application

Suitable for use as a command, measuring and control cable in tool making machinery conveyor system and production lines, in industrial
plants and in air conditioning as well as in the steel producing industries.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No. Part No. No.cores x AWG-no. Outer
grey
black
cross-sec.
ca. mm
mm
83137
83045
2 x 0,14
26
3,6
83138
83046
3 x 0,14
26
3,7
83139
83047
4 x 0,14
26
4,0
83140
83048
6 x 0,14
26
4,6
83141
83049
10 x 0,14
26
5,6
83142
83050
12 x 0,14
26
5,8
83143
83055
16 x 0,14
26
6,3
83144
83056
18 x 0,14
26
6,6
83145
83057
24 x 0,14
26
7,5
83146
83058
27 x 0,14
26
7,8
83147
83059
30 x 0,14
26
8,1
.
83153
83130
2 x 0,22
24
3,8
83154
83131
3 x 0,22
24
4,0
83155
83132
4 x 0,22
24
4,2
83156
83133
6 x 0,22
24
4,9
83157
83134
10 x 0,22
24
6,0
83158
83135
12 x 0,22
24
6,1
83159
83136
16 x 0,22
24
6,7
83160
83371
18 x 0,22
24
7,1
83161
83372
24 x 0,22
24
8,2
83162
83373
27 x 0,22
24
8,5
83163
83374
30 x 0,22
24
8,8
.
83169
83375
2 x 0,34
22
4,2
83170
83376
3 x 0,34
22
4,3
83171
83377
4 x 0,34
22
4,6
83172
83378
6 x 0,34
22
5,5
83173
83379
10 x 0,34
22
6,8
83174
83380
12 x 0,34
22
7,0
83175
83381
16 x 0,34
22
7,8
83176
83382
18 x 0,34
22
8,3
83177
83383
24 x 0,34
22
9,6
83178
83384
27 x 0,34
22
10,0
83179
83385
30 x 0,34
22
10,5
.

Cop.
weight
kg/km
3,6
4,0
5,4
8,1
13,4
16,2
21,5
34,4
32,4
36,3
40,4

Weight
ca. kg/km
13,0
15,0
18,0
25,0
38,0
46,0
56,0
62,0
82,0
97,0
110,0

4,6
7,1
9,4
14,2
23,8
28,5
38,1
43,1
59,7
64,7
71,9

16,0
19,0
23,0
32,0
55,0
60,0
75,0
82,0
116,0
140,0
150,0

6,5
9,8
13,0
19,6
32,5
39,1
52,0
59,0
79,0
88,0
97,8

25,0
30,0
45,0
60,0
80,0
105,0
130,0
140,0
190,0
207,0
225,0

Part No. Part No. No.cores x AWG-no. Outer


grey
black
cross-sec.
ca. mm
mm
83185
83386
2 x 0,56
20
4,6
83186
83387
3 x 0,56
20
4,8
83187
83388
4 x 0,56
20
5,2
83188
83389
6 x 0,56
20
6,1
83189
83390
10 x 0,56
20
7,6
83190
83391
12 x 0,56
20
8,0
83191
83392
16 x 0,56
20
8,8
83192
83393
18 x 0,56
20
9,4
83193
83394
24 x 0,56
20
11,0
83194
83395
27 x 0,56
20
11,3
83195
83396
30 x 0,56
20
11,8
.
83201
83397
2 x 0,82
18
6,1
83202
83398
3 x 0,82
18
6,4
83203
83399
4 x 0,82
18
6,9
83204
83474
6 x 0,82
18
8,1
83205
83475
10 x 0,82
18
10,4
83206
83476
12 x 0,82
18
10,9
83207
83477
16 x 0,82
18
12,2
83208
83478
18 x 0,82
18
13,0
83209
83479
24 x 0,82
18
15,2
83210
83480
27 x 0,82
18
15,8
83211
83481
30 x 0,82
18
16,3
.
83217
83482
2 x 1,3
16
6,9
83218
83483
3 x 1,3
16
7,3
83219
83484
4 x 1,3
16
7,9
83220
83491
6 x 1,3
16
9,6
83221
83492
10 x 1,3
16
12,4
83222
83493
12 x 1,3
16
12,8
83223
83494
16 x 1,3
16
14,6
83224
83495
18 x 1,3
16
15,5
83225
83496
24 x 1,3
16
18,1
83226
83497
27 x 1,3
16
18,7
83227
83498
30 x 1,3
16
19,5

Cop.
weight
kg/km
9,8
14,6
19,4
29,0
48,2
58,2
77,3
87,0
116,3
129,8
144,6

Weight
ca. kg/km
30,0
33,0
41,0
65,0
102,0
120,0
152,0
168,0
224,0
260,0
300,0

15,2
23,2
31,3
47,0
78,2
94,0
125,1
141,1
188,2
212,0
235,6

50,0
62,0
72,0
100,0
180,0
182,0
240,0
270,0
370,0
400,0
470,0

24,4
37,1
49,4
74,2
124,0
149,0
198,7
224,0
298,4
336,0
373,6

70,0
90,0
110,0
160,0
250,0
300,0
400,0
450,0
650,0
680,0
750,0

Dimensions and specifications may be changed without prior notice.

F 14

Command Cable UL (LiYY)

Technical data

Special PVC command cable, approved to


UL-Style 2516
Temperature range
-20C to +105C
Nominal voltage 600 V
Test voltage 2000 V
Breakdown voltage
min. 4000 V
Minimum bending radius
flexing approx. 15x cable

Cable construction

600V, Style 2516/600 V, (105C)

Tinned copper, fine wire conductors to


ASTM-B 174, class J-K
Conductor make-up to:
2,08 mm = 41x0,254 mm
3,20 mm = 65x0,254 mm
Special PVC core insulation class 43 to
UL-Std. 1581 table 50.182 (105C)
Colour coded to DIN 47100 or international
colour code
Cores stranded in layers with optimal
lay-length
Special PVC outer jacket class 43 to
UL-Std. 1581 table 50.182 (105C)
Outer jacket colour
black (international colour code)
grey (DIN 47100 / preferred type from
stock)

Properties

PVC flame retardant according to UL VW-1


Conditionally resistant to
Oil
Solvents
Acids
Lyes
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application

Suitable for use as a command, measuring and control cable in tool making machinery conveyor system and production lines, in industrial
plants and in air conditioning as well as in the steel producing industries.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No. Part No. No.cores x AWG-no. Outer
grey
black
cross-sec.
ca. mm
mm
83233
83624
2 x 2,08
14
8,4
83234
83625
3 x 2,08
14
8,9
83235
83626
4 x 2,08
14
9,6
83236
83627
6 x 2,08
14
11,4
83237
83628
10 x 2,08
14
15,1
83238
83629
12 x 2,08
14
15,6
83239
83630
16 x 2,08
14
17,2
83240
83631
18 x 2,08
14
18,3
83241
83632
24 x 2,08
14
21,5
83242
83633
27 x 2,08
14
22,7
83243
83634
30 x 2,08
14
23,5
83244
83635
36 x 2,08
14
25,4
.

Cop.
weight
kg/km
39,6
59,6
79,2
119,0
198,4
238,7
319,0
358,4
478,4
538,1
598,4
717,2

Weight
ca. kg/km
120,0
150,0
190,0
300,0
450,0
500,0
700,0
750,0
900,0
1100,0
1150,0
1800,0

Dimensions and specifications may be changed without prior notice.

F 15

Part No. Part No. No.cores x AWG-no. Outer


grey
black
cross-sec.
ca. mm
mm
83245
83636
2 x 3,2
12
9,3
83246
83637
3 x 3,2
12
9,8
83247
83638
4 x 3,2
12
10,8
83248
83639
6 x 3,2
12
12,8
83249
83640
10 x 3,2
12
17,0
83250
83641
12 x 3,2
12
17,5
83251
83642
16 x 3,2
12
19,8
83252
83643
18 x 3,2
12
21,0
83253
83644
24 x 3,2
12
24,8

Cop.
weight
kg/km
61,0
91,4
121,6
183,7
305,9
367,6
490,9
551,7
736,4

Weight
ca. kg/km
150,0
210,0
300,0
430,0
500,0
700,0
810,0
970,0
1200,0

Command Cable UL (LiYCY)

Style 2464, 300V, 80C,

EMC-preferred type

Technical data

Special PVC command cable, approved to


UL-Style 2464, cores according
AWG 26-20 to UL-Style 1061/1729
AWG 18-16 to UL-Style 1007/1569
Temperature range
-20C to +80C
Nominal voltage 300 V
Test voltage 1500 V
Breakdown voltage
min. 3000 V
Minimum bending radius
flexing approx. 15x cable
Coupling resistance
max. 250 Ohm/km

Cable construction

Tinned copper, fine wire conductors


AWG 26-20 gem. ASTM-B 174-95 class J-M,
AWG 18-16 gem. ASTM-B 286
conductor make-up to
0,14 mm = 7x0,162 mm
0,22 mm = 7x0,202 mm
0,34 mm = 7x0,254 mm
0,56 mm = 7x0,32 mm
0,82 mm = 19x0,235 mm
1,30 mm = 19x0,31 mm
Special PVC core insulation class 43,
semirigid to UL-Std. 1581 table 50.182
and 50.183
Colour coded to DIN 47100 or international
colour code
Cores stranded in layers with optimal
lay-length
Seperator-foil
Drain wire
Tinned copper wire braiding, approx. 85%
coverage
Special PVC outer jacket class 43 to
UL-Std. 1581 table 50.182
Outer jacket colour
black (international colour code)
grey (DIN 47100 / preferred type from
stock)

Properties

PVC flame retardant according to UL VW-1


Conditionally resistant to
Oil
Solvents
Acids
Lyes
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application

This cable type is suitable for use as a flexible connector cable in the fields of electronics, control and command technology as well as for
measuring, signal and impulse transfer. Quick and cost favourable connections through cutting and clamping technics.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the cooper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No. Part No. No.cores x AWG-no. Outer
grey
black
cross-sec.
ca. mm
mm
83254
83976
2 x 0,14
26
4,1
83255
83977
3 x 0,14
26
4,3
83256
83978
4 x 0,14
26
4,5
83257
83979
6 x 0,14
26
5,1
83258
83980
10 x 0,14
26
6,1
83259
83981
12 x 0,14
26
6,3
83260
83982
16 x 0,14
26
6,8
83261
83983
18 x 0,14
26
7,0
83262
83984
24 x 0,14
26
8,1
83263
83985
27 x 0,14
26
8,3
83264
83986
30 x 0,14
26
8,6
.

Cop.
weight
kg/km
12,6
13,7
14,9
18,9
29,5
31,4
43,9
52,1
62,8
66,3
70,4

Weight
ca. kg/km

Dimensions and specifications may be changed without prior notice.

20,0
25,0
28,0
30,0
50,0
53,0
60,0
70,0
100,0
105,0
110,0

Part No. Part No. No.cores x AWG-no. Outer


grey
black
cross-sec.
ca. mm
mm
83270
83987
2 x 0,22
24
4,3
83271
83988
3 x 0,22
24
4,5
83272
83989
4 x 0,22
24
4,8
83273
83990
6 x 0,22
24
5,4
83274
83991
10 x 0,22
24
6,5
83275
83992
12 x 0,22
24
6,7
83276
83993
16 x 0,22
24
7,4
83277
83994
18 x 0,22
24
7,7
83278
83995
24 x 0,22
24
8,8
83279
83996
27 x 0,22
24
9,0
83280
83997
30 x 0,22
24
9,3
.

Cop.
weight
kg/km
16,1
18,9
23,0
32,8
50,9
59,1
68,4
79,5
97,3
122,0
132,0

Weight
ca. kg/km
20,0
25,0
30,0
40,0
60,0
70,0
90,0
123,0
131,0
160,0
170,0
Continuation

F 16

Command Cable UL (LiYCY)

Style 2464, 300V, 80C,

EMC-preferred type

Part No. Part No. No.cores x AWG-no. Outer


grey
black
cross-sec.
ca. mm
mm
83286
65044
2 x 0,34
22
4,7
83287
65045
3 x 0,34
22
4,9
83288
65046
4 x 0,34
22
5,5
83289
65047
6 x 0,34
22
6,0
83290
65048
10 x 0,34
22
7,4
83291
65049
12 x 0,34
22
7,6
83292
65050
16 x 0,34
22
8,3
83293
65051
18 x 0,34
22
8,7
83294
65052
24 x 0,34
22
10,0
83295
65053
27 x 0,34
22
10,2
83296
65054
30 x 0,34
22
10,5
.
83302
65055
2 x 0,56
20
5,1
83303
65056
3 x 0,56
20
5,3
83304
65057
4 x 0,56
20
5,6
83305
65058
6 x 0,56
20
6,5
83306
65059
10 x 0,56
20
8,2
83307
65060
12 x 0,56
20
8,4
83308
65061
16 x 0,56
20
9,3
83309
65062
18 x 0,56
20
9,7
83310
65063
24 x 0,56
20
11,3
83311
65064
27 x 0,56
20
11,5
83312
65065
30 x 0,56
20
12,3
.

Cop.
weight
kg/km
18,1
22,2
28,7
45,4
66,1
70,8
88,4
104,1
129,0
138,4
159,0

Weight
ca. kg/km

29,4
39,7
46,1
66,8
93,1
117,4
130,4
151,4
237,0
257,4
297,0

Dimensions and specifications may be changed without prior notice.

F 17

40,0
50,0
60,0
80,0
130,0
140,0
160,0
170,0
220,0
250,0
280,0
50,0
55,0
61,0
90,0
133,0
151,0
190,0
216,0
339,0
374,0
397,0

Part No. Part No. No.cores x AWG-no. Outer


grey
black
cross-sec.
ca. mm
mm
83318
65066
2 x 0,83
18
6,5
83319
65067
3 x 0,83
18
6,8
83320
65068
4 x 0,83
18
7,4
83321
65069
6 x 0,83
18
8,8
83322
65070
10 x 0,83
18
10,9
83323
65071
12 x 0,83
18
11,2
83324
65072
16 x 0,83
18
12,9
83325
65073
18 x 0,83
18
13,5
83326
65074
24 x 0,83
18
15,6
83327
65075
27 x 0,83
18
15,9
83328
65076
30 x 0,83
18
16,6
.
83334
65077
2 x 1,31
16
7,0
83335
65078
3 x 1,31
16
7,4
83336
65079
4 x 1,31
16
8,1
83337
65080
6 x 1,31
16
9,5
83338
65081
10 x 1,31
16
12,4
83339
65082
12 x 1,31
16
12,8
83340
65083
16 x 1,31
16
14,0
83341
65084
18 x 1,31
16
14,8
83342
65085
24 x 1,31
16
17,2
83343
65086
27 x 1,31
16
18,0
83344
65087
30 x 1,31
16
18,7

Cop.
weight
kg/km
39,1
50,0
59,1
89,1
141,4
152,8
184,1
207,2
272,6
289,1
317,4

Weight
ca. kg/km

59,1
74,1
96,4
137,4
191,7
251,7
276,1
364,1
442,4
494,7
521,4

90,0
160,0
200,0
290,0
450,0
600,0
650,0
680,0
900,0
990,0
1050,0

60,0
75,0
90,0
125,0
180,0
220,0
290,0
300,0
450,0
470,0
490,0

Command Cable UL (LiYCY)

Style 2516/600 V, 105C,

EMC-preferred type

Technical data

Special PVC command cable, approved to


UL-Style 2516 cores according
UL-Style 10012
Temperature range
-20C to +105C
Nominal voltage 600 V
Test voltage 2000 V
Breakdown voltage
min. 4000 V
Minimum bending radius
flexing approx. 15x cable
Coupling resistance
max. 250 Ohm/km

Cable construction

Tinned copper, fine wire conductors to


ASTM-B 174, class J-K
conductor make-up to
2,08 mm = 41x0,254 mm
3,20 mm = 65x0,254 mm
Special PVC core insulation class 43 to
UL-Std. 1581 table 50.182 (105C)
Colour coded to DIN 47100 or international
colour code
Cores stranded in layers with optimal
lay-length
Seperator-foil
Drain wire
Tinned copper wire braiding, approx. 85%
coverage
Special PVC outer jacket class 43 to
UL-Std. 1581 table 50.182 (105C)
Outer jacket colour
black (international colour code)
grey (DIN 47100 / preferred type from
stock)

Properties

PVC flame retardant according to UL VW-1


Conditionally resistant to
Oil
Solvents
Acids
Lyes
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application

This cable type is suitable for use as a flexible connector cable in the fields of electronics, control and command technology as well as for
measuring, signal and impulse transfer. Quick and cost favourable connections through cutting and clamping technics.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the cooper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No. Part No. No.cores x AWG-no. Outer
grey
black
cross-sec.
ca. mm
mm
83350
65114
2 x 2,08
14
8,9
83351
65115
3 x 2,08
14
9,4
83352
65116
4 x 2,08
14
10,1
83353
65117
6 x 2,08
14
11,9
83354
65118
10 x 2,08
14
15,7
83355
65119
12 x 2,08
14
16,2
83356
65120
16 x 2,08
14
17,9
83357
65121
18 x 2,08
14
18,8
83358
65122
24 x 2,08
14
22,6
83359
65123
27 x 2,08
14
23,3
83360
65124
30 x 2,08
14
24,1
.

Cop.
weight
kg/km
92,1
140,6
162,4
200,0
313,1
417,6
510,3
540,4
580,6
604,2
660,1

Weight
ca. kg/km
180,0
220,0
270,0
380,0
600,0
770,0
870,0
990,0
1300,0
1400,0
1610,0

Part No. Part No. No.cores x AWG-no. Outer


grey
black
cross-sec.
ca. mm
mm
83362
65125
2 x 3,2
12
9,9
83363
65126
3 x 3,2
12
10,3
83364
65127
4 x 3,2
12
11,2
83365
65128
6 x 3,2
12
14,0
83366
65129
10 x 3,2
12
17,6
83367
65130
12 x 3,2
12
18,1
83368
65131
16 x 3,2
12
20,0
83369
65132
18 x 3,2
12
22,1
83370
65133
24 x 3,2
12
25,3

Cop.
weight
kg/km
131,4
162,6
221,7
328,1
401,8
460,2
532,3
573,4
626,8

Weight
ca. kg/km
200,0
240,0
300,0
400,0
580,0
800,0
900,0
1000,0
1300,0

Dimensions and specifications may be changed without prior notice.

F 18

Command Cable UL (LiYY-TP)

Technical data

Special PVC command cable, approved to


UL-Style 2464,cores according,
UL-Style 1061/1729
Temperature range
flexing -10C to +80C
fixed installation -20C to +80C
Nominal voltage 300 V
Test voltage 1500 V
Breakdown voltage
min. 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing approx. 15x cable

Style 2464/300V, 80C

Cable construction

Tinned copper, fine wire conductors to


ASTM-B 174-95 class J-M
conductor make-up to
0,14 mm = 7x0,162 mm
0,22 mm = 7x0,202 mm
0,34 mm = 7x0,254 mm
0,56 mm = 7x0,32 mm
Special PVC core insulation class 43,
semirigid to UL-Std. 1581 table 50.182
and 50183
Colour coded to DIN 47100 with colour
repetition from pair no. 23 and above or
international colour code
Cores stranded in pairs with optimal
lay-length
Pairs stranded in layers with optimal
lay-length
Seperator-foil
Special PVC outer jacket class 43 to
UL-Std. 1581 table 50.182
Outer jacket colour
black (international colour code)
grey (DIN 47100 / preferred type)

Properties

PVC flame retardant according to UL VW-1


Conditionally resistant to
Oil
Solvents
Acids
Lyes
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application

Twisted pair control cable for use in tool making machinery conveyor system and production lines, in industrial plants and in air conditioning
as well as in the steel producing industries.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No. No.pairs x
grey
cross-sec.
mm
83904
1 x 2 x 0,14
83905
2 x 2 x 0,14
83906
3 x 2 x 0,14
83907
4 x 2 x 0,14
83908
5 x 2 x 0,14
83909
6 x 2 x 0,14
83910
7 x 2 x 0,14
83911
8 x 2 x 0,14
83912
10 x 2 x 0,14
83913
12 x 2 x 0,14
83914
14 x 2 x 0,14
83915
15 x 2 x 0,14
83916
16 x 2 x 0,14
83917
18 x 2 x 0,14
83918
20 x 2 x 0,14
83919
22 x 2 x 0,14
83920
24 x 2 x 0,14
83921
25 x 2 x 0,14
.
83922
1 x 2 x 0,22
83923
2 x 2 x 0,22
83924
3 x 2 x 0,22
83925
4 x 2 x 0,22
83926
5 x 2 x 0,22
83927
6 x 2 x 0,22
83928
7 x 2 x 0,22
83929
8 x 2 x 0,22
83930
10 x 2 x 0,22
83931
12 x 2 x 0,22
83932
14 x 2 x 0,22
83933
15 x 2 x 0,22
83934
16 x 2 x 0,22
83935
18 x 2 x 0,22
83936
20 x 2 x 0,22
83937
22 x 2 x 0,22
83938
24 x 2 x 0,22
83939
25 x 2 x 0,22

AWG-no. Outer
ca. mm
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26

3,6
5,1
5,3
5,8
6,2
6,8
6,8
7,3
7,4
9,1
9,8
10,6
10,6
11,1
11,9
12,4
13,1
13,4

Cop.
Weight
weight ca. kg / km
kg / km
2,7
20,0
5,4
24,0
8,1
30,0
10,8
38,0
13,6
44,0
16,2
51,0
19,0
57,0
21,7
64,0
26,7
76,0
32,6
93,0
37,4
103,0
40,7
109,0
43,4
112,0
48,5
119,0
54,2
130,0
59,3
150,0
64,7
169,0
67,2
178,0

24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24

3,8
4,0
5,7
6,0
6,6
7,2
7,2
7,8
9,2
9,7
10,2
10,9
10,9
11,5
12,2
13,0
13,7
14,2

4,8
9,7
14,7
19,6
24,6
29,3
34,1
39,1
48,9
59,4
68,7
73,7
79,1
88,9
98,4
108,6
117,9
123,5

32,0
36,0
48,0
56,0
71,0
80,0
89,0
98,0
111,0
135,0
160,0
171,0
185,0
209,0
230,0
248,0
279,0
292,0

Dimensions and specifications may be changed without prior notice.

F 19

Part No. No.pairs x


grey
cross-sec.
mm
83940
1 x 2 x 0,34
83941
2 x 2 x 0,34
83942
3 x 2 x 0,34
83943
4 x 2 x 0,34
83944
5 x 2 x 0,34
83945
6 x 2 x 0,34
83946
7 x 2 x 0,34
83947
8 x 2 x 0,34
83948
10 x 2 x 0,34
83949
12 x 2 x 0,34
83950
14 x 2 x 0,34
83951
15 x 2 x 0,34
83952
16 x 2 x 0,34
83953
18 x 2 x 0,34
83954
20 x 2 x 0,34
83955
22 x 2 x 0,34
83956
24 x 2 x 0,34
83957
25 x 2 x 0,34
.
83958
1 x 2 x 0,56
83959
2 x 2 x 0,56
83960
3 x 2 x 0,56
83961
4 x 2 x 0,56
83962
5 x 2 x 0,56
83963
6 x 2 x 0,56
83964
7 x 2 x 0,56
83965
8 x 2 x 0,56
83966
10 x 2 x 0,56
83967
12 x 2 x 0,56
83968
14 x 2 x 0,56
83969
15 x 2 x 0,56
83970
16 x 2 x 0,56
83971
18 x 2 x 0,56
83972
20 x 2 x 0,56
83973
22 x 2 x 0,56
83974
24 x 2 x 0,56
83975
25 x 2 x 0,56

AWG-no. Outer
ca. mm
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22

4,2
5,9
6,3
7,0
7,6
8,2
8,2
9,0
10,7
11,3
12,1
12,7
12,7
13,6
14,4
15,1
16,2
16,7

Cop.
Weight
weight ca. kg / km
kg / km
6,5
38,0
13,0
44,0
19,5
60,0
26,1
79,0
32,6
92,0
39,2
119,0
45,7
128,0
52,3
139,0
65,3
171,0
78,4
194,0
91,5
222,0
97,8
231,0
104,6
240,0
117,8
264,0
130,7
291,0
143,6
300,0
156,8
359,0
163,3
381,0

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

4,6
6,5
7,1
7,8
8,6
9,6
9,6
12,1
12,5
13,1
13,8
14,7
14,7
15,7
16,7
17,2
18,6
19,2

10,8
21,5
32,3
43,1
53,8
64,6
75,3
86,1
107,7
129,1
150,6
161,3
172,1
193,6
215,1
236,6
258,0
268,9

60,0
80,0
94,0
104,0
130,0
151,0
174,0
262,0
298,0
302,0
327,0
370,0
402,0
480,0
551,0
621,0
703,0
721,0
Continuation

Command Cable UL (LiYY-TP)


Part No. No.pairs x
black
cross-sec.
mm
65214
1 x 2 x 0,14
65215
2 x 2 x 0,14
65216
3 x 2 x 0,14
65217
4 x 2 x 0,14
65218
5 x 2 x 0,14
65219
6 x 2 x 0,14
65220
7 x 2 x 0,14
65221
8 x 2 x 0,14
65222
10 x 2 x 0,14
65223
12 x 2 x 0,14
65224
14 x 2 x 0,14
65225
15 x 2 x 0,14
65226
16 x 2 x 0,14
65227
18 x 2 x 0,14
65228
20 x 2 x 0,14
65229
22 x 2 x 0,14
65230
24 x 2 x 0,14
65231
25 x 2 x 0,14
.
65232
1 x 2 x 0,22
65233
2 x 2 x 0,22
65234
3 x 2 x 0,22
65235
4 x 2 x 0,22
65236
5 x 2 x 0,22
65237
6 x 2 x 0,22
65238
7 x 2 x 0,22
65239
8 x 2 x 0,22
65240
10 x 2 x 0,22
65241
12 x 2 x 0,22
65242
14 x 2 x 0,22
65243
15 x 2 x 0,22
65244
16 x 2 x 0,22
65245
18 x 2 x 0,22
65246
20 x 2 x 0,22
65247
22 x 2 x 0,22
65248
24 x 2 x 0,22
65249
25 x 2 x 0,22

AWG-no. Outer
ca. mm
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26

3,6
5,1
5,3
5,8
6,2
6,8
6,8
7,3
7,4
9,1
9,8
10,6
10,6
11,1
11,9
12,4
13,1
13,4

Cop.
Weight
weight ca. kg / km
kg / km
2,7
20,0
5,4
24,0
8,1
30,0
10,8
38,0
13,6
44,0
16,2
51,0
19,0
57,0
21,7
64,0
26,7
76,0
32,6
93,0
37,4
103,0
40,7
109,0
43,4
112,0
48,5
119,0
54,2
130,0
59,3
150,0
64,7
169,0
67,2
178,0

24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24

3,8
4,0
5,7
6,0
6,6
7,2
7,2
7,8
9,2
9,7
10,2
10,9
10,9
11,5
12,2
13,0
13,7
14,2

4,8
9,7
14,7
19,6
24,6
29,3
34,1
39,1
48,9
59,4
68,7
73,7
79,1
88,9
98,4
108,6
117,9
123,5

32,0
36,0
48,0
56,0
71,0
80,0
89,0
98,0
111,0
135,0
160,0
171,0
185,0
209,0
230,0
248,0
279,0
292,0

Style 2464/300V, 80C

Part No. No.pairs x


black
cross-sec.
mm
65250
1 x 2 x 0,34
65251
2 x 2 x 0,34
65252
3 x 2 x 0,34
65253
4 x 2 x 0,34
65254
5 x 2 x 0,34
65255
6 x 2 x 0,34
65256
7 x 2 x 0,34
65257
8 x 2 x 0,34
65258
10 x 2 x 0,34
65259
12 x 2 x 0,34
65260
14 x 2 x 0,34
65261
15 x 2 x 0,34
65262
16 x 2 x 0,34
65263
18 x 2 x 0,34
65264
20 x 2 x 0,34
65265
22 x 2 x 0,34
65266
24 x 2 x 0,34
65267
25 x 2 x 0,34
.
65268
1 x 2 x 0,56
65269
2 x 2 x 0,56
65270
3 x 2 x 0,56
65271
4 x 2 x 0,56
65272
5 x 2 x 0,56
65273
6 x 2 x 0,56
65274
7 x 2 x 0,56
65275
8 x 2 x 0,56
65276
10 x 2 x 0,56
65277
12 x 2 x 0,56
65278
14 x 2 x 0,56
65279
15 x 2 x 0,56
65280
16 x 2 x 0,56
65281
18 x 2 x 0,56
65282
20 x 2 x 0,56
65283
22 x 2 x 0,56
65284
24 x 2 x 0,56
65285
25 x 2 x 0,56

AWG-no. Outer
ca. mm
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22
22

4,2
5,9
6,3
7,0
7,6
8,2
8,2
9,0
10,7
11,3
12,1
12,7
12,7
13,6
14,4
15,1
16,2
16,7

Cop.
Weight
weight ca. kg / km
kg / km
6,5
38,0
13,0
44,0
19,5
60,0
26,1
79,0
32,6
92,0
39,2
119,0
45,7
128,0
52,3
139,0
65,3
171,0
78,4
194,0
91,5
222,0
97,8
231,0
104,6
240,0
117,8
264,0
130,7
291,0
143,6
300,0
156,8
359,0
163,3
381,0

20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

4,6
6,5
7,1
7,8
8,6
9,6
9,6
12,1
12,5
13,1
13,8
14,7
14,7
15,7
16,7
17,2
18,6
19,2

10,8
21,5
32,3
43,1
53,8
64,6
75,3
86,1
107,7
129,1
150,6
161,3
172,1
193,6
215,1
236,6
258,0
268,9

60,0
80,0
94,0
104,0
130,0
151,0
174,0
262,0
298,0
302,0
327,0
370,0
402,0
480,0
551,0
621,0
703,0
721,0

Dimensions and specifications may be changed without prior notice.

F 20

Command Cable UL (LiYCY-TP) Style 2464/300 V, 80C,

EMC-preferred type

Technical data

Special PVC command cable, approved to


UL-Style 2464,cores according,
UL-Style 1061/1729
Temperature range
flexing -10C to +80C
fixed installation -20C to +80C
Nominal voltage 300 V
Test voltage 1500 V
Breakdown voltage
min. 3000 V
Insulation resistance
min. 100 MOhm x km
Minimum bending radius
flexing approx. 20x cable
Coupling resistance
max. 250 Ohm/km

Cable construction

Tinned copper, fine wire conductors to


ASTM-B 174-95 class J-M
Conductor make-up to
0,14 mm = 7x0,162 mm
0,22 mm = 7x0,202 mm
0,34 mm = 7x0,254 mm
0,56 mm = 7x0,32 mm
Special PVC core insulation class 43,
semirigid to UL-Std. 1581 table 50.182
and 50183
Colour coded to DIN 47100 with colour
repetition from pair no. 22 and above or
international colour code
Cores stranded in pains with optimal
lay-length
Pains stranded in layers with optimal
lay-length
Seperator-foil
Drain wire
Tinned copper wire braiding, approx. 85%
coverage
Special PVC outer jacket class 43 to
UL-Std. 1581 table 50.182
Outer jacket colour
black (international colour code)
grey (DIN 47100 / preferred type from
stock)

Properties

PVC flame retardant according to UL VW-1


Conditionally resistant to
Oil
Solvents
Acids
Lyes
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application

Twisted pair control cable for use in tool making machinery conveyor system and production lines, in industrial plants and in air conditioning
as well as in the steel producing industries.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the cooper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No. Part No. No.pairs x
AWG-no. Outer
grey
black
cross-sec.
ca. mm
mm
83774
65314
1 x 2 x 0,14 26
4,0
83775
65315
2 x 2 x 0,14 26
5,6
83776
65316
3 x 2 x 0,14 26
5,8
83777
65317
4 x 2 x 0,14 26
6,3
83778
65318
5 x 2 x 0,14 26
6,7
83779
65319
6 x 2 x 0,14 26
7,3
83780
65320
7 x 2 x 0,14 26
7,3
83781
65321
8 x 2 x 0,14 26
7,8
83782
65322
10 x 2 x 0,14 26
9,1
83783
65323
12 x 2 x 0,14 26
9,8
83784
65324
14 x 2 x 0,14 26
10,5
83785
65325
15 x 2 x 0,14 26
11,1
83786
65326
16 x 2 x 0,14 26
11,1
83787
65327
18 x 2 x 0,14 26
11,8
83788
65328
20 x 2 x 0,14 26
12,4
83789
65329
22 x 2 x 0,14 26
13,1
83790
65330
24 x 2 x 0,14 26
13,6
83791
65331
25 x 2 x 0,14 26
15,1
.

Cop.
weight
kg/km
15,7
19,5
23,7
26,9
31,2
49,7
52,0
53,9
59,6
67,1
75,2
77,3
80,4
84,2
98,2
104,1
112,0
114,4

Weight
ca. kg/km

Dimensions and specifications may be changed without prior notice.

F 21

32,0
39,0
47,0
55,0
68,0
86,0
92,0
97,0
111,0
141,0
150,0
154,0
155,0
170,0
183,0
207,0
228,0
239,0

Part No. Part No. No.pairs x


AWG-no. Outer
grey
black
cross-sec.
ca. mm
mm
83792
65332
1 x 2 x 0,22 24
4,2
83793
65333
2 x 2 x 0,22 24
5,9
83794
65334
3 x 2 x 0,22 24
6,2
83795
65335
4 x 2 x 0,22 24
6,7
83796
65336
5 x 2 x 0,22 24
7,2
83797
65337
6 x 2 x 0,22 24
7,7
83798
65338
7 x 2 x 0,22 24
7,7
83799
65339
8 x 2 x 0,22 24
8,4
83800
65340
10 x 2 x 0,22 24
9,9
83801
65341
12 x 2 x 0,22 24
10,2
83802
65342
14 x 2 x 0,22 24
10,9
83803
65343
15 x 2 x 0,22 24
11,4
83804
65344
16 x 2 x 0,22 24
11,4
83805
65345
18 x 2 x 0,22 24
12,2
83806
65346
20 x 2 x 0,22 24
12,7
83807
65347
22 x 2 x 0,22 24
13,5
83808
65348
24 x 2 x 0,22 24
14,5
83809
65349
25 x 2 x 0,22 24
14,8
.

Cop.
weight
kg/km
16,4
27,4
31,7
37,4
54,7
65,6
60,2
74,1
109,3
115,8
120,7
132,4
141,6
146,6
160,6
170,8
229,7
231,4

Weight
ca. kg/km
46,0
53,0
65,0
79,0
98,0
114,0
121,0
129,0
152,0
189,0
213,0
225,0
227,0
238,0
270,0
300,0
321,0
340,0
Continuation

Command Cable UL (LiYCY-TP) Style 2464/300 V, 80C,

EMC-preferred type

Part No. Part No. No.pairs x


AWG-no. Outer
grey
black
cross-sec.
ca. mm
mm
83810
65350
1 x 2 x 0,34 22
4,6
83811
65351
2 x 2 x 0,34 22
6,4
83812
65352
3 x 2 x 0,34 22
6,9
83813
65353
4 x 2 x 0,34 22
7,5
83814
65354
5 x 2 x 0,34 22
8,1
83815
65355
6 x 2 x 0,34 22
8,8
83816
65356
7 x 2 x 0,34 22
8,8
83817
65357
8 x 2 x 0,34 22
9,7
83818
65358
10 x 2 x 0,34 22
11,5
83819
65359
12 x 2 x 0,34 22
12,0
83820
65360
14 x 2 x 0,34 22
12,6
83821
65361
15 x 2 x 0,34 22
13,4
83822
65362
16 x 2 x 0,34 22
13,4
83823
65363
18 x 2 x 0,34 22
14,4
83824
65364
20 x 2 x 0,34 22
15,0
83825
65365
22 x 2 x 0,34 22
15,9
83826
65366
24 x 2 x 0,34 22
17,0
83827
65367
25 x 2 x 0,34 22
17,3
.

Cop.
weight
kg/km
17,0
36,7
44,6
54,1
63,4
73,4
79,4
88,4
107,0
122,4
138,2
154,3
161,4
197,9
211,4
217,6
230,4
138,5

Weight
ca. kg/km
58,0
65,0
78,0
88,0
110,0
126,0
140,0
148,0
184,0
210,0
241,0
245,0
251,0
275,0
300,0
320,0
371,0
402,0

Part No. Part No. No.pairs x


AWG-no. Outer
grey
black
cross-sec.
ca. mm
mm
83828
65368
1 x 2 x 0,56 20
5,0
83829
65369
2 x 2 x 0,56 20
7,0
83830
65370
3 x 2 x 0,56 20
7,6
83831
65371
4 x 2 x 0,56 20
8,3
83832
65372
5 x 2 x 0,56 20
9,1
83833
65373
6 x 2 x 0,56 20
10,1
83834
65374
7 x 2 x 0,56 20
10,1
83835
65375
8 x 2 x 0,56 20
12,7
83836
65376
10 x 2 x 0,56 20
13,2
83837
65377
12 x 2 x 0,56 20
13,6
83838
65378
14 x 2 x 0,56 20
14,4
83839
65379
15 x 2 x 0,56 20
15,5
83840
65380
16 x 2 x 0,56 20
15,5
83841
65381
18 x 2 x 0,56 20
16,3
83842
65382
20 x 2 x 0,56 20
17,1
83843
65383
22 x 2 x 0,56 20
18,0
83844
65384
24 x 2 x 0,56 20
19,4
83845
65385
25 x 2 x 0,56 20
19,8

Cop.
weight
kg/km
26,0
56,1
71,7
92,4
107,4
122,4
131,7
144,3
179,6
201,7
221,4
231,6
257,1
282,4
306,7
321,8
342,4
361,2

Weight
ca. kg/km
70,0
89,0
102,0
119,0
140,0
162,0
198,0
272,0
307,0
318,0
342,0
381,0
417,0
494,0
570,0
643,0
724,0
740,0

Dimensions and specifications may be changed without prior notice.

F 22

Rubber / Neoprene Control Cable Types SJO und SO

Technical data

UL+CSA approved rubber/neoprene flexible


cables
Temperature range
SJO and SO -40C to +90C
Nominal voltage
300 V for SJO
600 V for SO
Approvals
UL Subject 62
CSA-C22.2-49

Cable construction

Plain copper conductors to ASTM B-174


Core insulation of synthetic rubber, EPDM
Cores colour coded
Cores stranded in layers with optimal
lay-length
Hemp or cotton tape
Outer jacket neoprene (oil resistant)
Jacket colour black

Properties

Resistant
Oil
Wetness
UV-radiation
Colour code
2 cores black, white
3 cores black, white, green
4 cores black, white, green, red

Note

Note: SJO- 18/2


18 = AWG 18
2 = No. of cores
Supply lengths are on original reels of 76
m or 152 m or on drums of 305 m lengths.
Further Types also available: PVC control
cables SJT, SJTO, ST, STO.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application

For use as a feeder cable under rough conditions in motors and machine construction, at shipyards, in steel production and in farming.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Nominal voltage 300 Volt, type SJO (90C)
Part No.

No.cores
/ AWG-no.

63010
63011
63012
63013
63014
63015
63016
63017
63018

2 / 18
3 / 18
4 / 18
2 / 16
3 / 16
4 / 16
2 / 14
3 / 14
4 / 14

Current
carrying
capacity
in Amp.
7
7
7
10
10
10
15
15
15

Nominal voltage 600 Volt, type SO (90C)

Part No.

No.cores
/ AWG-no.

63034
63035
63036
63037
63038
63039
63040
63041
63042
63043
63044
63045
63046
63047
63048

2 / 18
3 / 18
4 / 18
2 / 16
3 / 16
4 / 16
2 / 14
3 / 14
4 / 14
2 / 12
3 / 12
4 / 12
2 / 10
3 / 10
4 / 10

Current
carrying
capacity
in Amp.
7
7
7
10
10
10
15
15
15
20
20
20
25
25
25

Dimensions and specifications may be changed without prior notice.

F 23

Cond.
make-up
n x wire
16 x 0,3
16 x 0,3
16 x 0,3
26 x 0,3
26 x 0,3
26 x 0,3
41 x 0,3
41 x 0,3
41 x 0,3

Cond.
make-up
n x wire
16 x 0,3
16 x 0,3
16 x 0,3
26 x 0,3
26 x 0,3
26 x 0,3
41 x 0,3
41 x 0,3
41 x 0,3
65 x 0,3
65 x 0,3
65 x 0,3
105 x 0,3
105 x 0,3
105 x 0,3

Outer
ca. mm
7,8
8,4
9,2
8,3
9,0
10,0
9,4
10,0
10,7

Outer
ca. mm
10,0
10,4
11,0
10,4
11,0
12,3
13,5
14,3
15,3
15,3
16,2
18,9
16,4
17,5
19,0

Weight
ca. kg / km
65,0
80,0
95,0
130,0
148,0
180,0
195,0
225,0
288,0

Weight
ca. kg / km
70,0
86,0
110,0
140,0
155,0
200,0
200,0
235,0
300,0
280,0
310,0
330,0
305,0
325,0
365,0

PVC Single Core

Technical data

PVC-Single Cores as per Italian standard


CEI 20-22 II
Temperature range
flexing -5C to +80C
fixed installation -30C to +80C
Nominal voltage
U0/U 450/750 V = 1 mm and above
U0/U 300/500 V = 0,5 and 0,75 mm
U0/U 300/300 V = 0,35 mm
Test voltage 2500 V
Minimum bending radius
4-6x cable

to CEI 20-22 II

Cable construction

Bare fine wire stranded copper conductor


to CEI 20-29 cl. 5
PVC-core insulation R 2 up to CEI 20 II,
cap. VI cl. 3

Properties

Low smoke
Resistant to
Oil
Solvents
Acids
Lyes
PVC self-extinguishing and flame retardant
according to DIN VDE 0482 part 265-2-1/
EN 50265-2-1/ IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

AWG sizes are approximate equivalent


values. The actual cross-section is in mm.

Application

As hook up wire, control cabinet building, in cable assembly manufacturing as well as in electronic applications.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Cross-sec.
mm
ca. RAL
Part No.
0,35
Part No.
0,5
Part No.
0,75
Part No.
1
Part No.
1,5
Part No.
2,5
Part No.
4
Part No.
6
Part No.
10
Part No.
16
Part No.
25
Part No.
35
Part No.
50
Part No.
70
Part No.
95
Part No.
120
Part No.
150

Outer
ca. mm

Cop.
weight
kg / km

Weight
ca. kg / km

1.5

2,5

3,6

2.6

4,8

6,0

2.8

7,2

10,0

3.2

9,6

16,0

3.5

14,4

21,0

4.2

24,0

32,0

4.6

38,0

48,0

6.3

58,0

69,0

7.6

96,0

117,0

8.8

154,0

180,0

11.0

240,0

266,0

12.5

336,0

366,0

14.5

480,0

515,0

16.5

672,0

741,0

18.5

912,0

950,0

21.0

1152,0

1230,0

23.0

1440,0

1500,0

black

gn-ye

blue

brown

red

white

dk-bu

o.col.

9005
29600

29601

5015
29602

8003
29603

3000
29604

1013
29605

5010
29606

29607

29608
20
29616
18
29624
17
29632
16
29640
14
29648
12
29656
10
29664
8
29672
6
29680
4
29688
2
29696
1
29704
2/0
29712
3/0
29720
4/0
29728
300 kcmil

29609

29610

29611

29612

29613

29614

29615

29617

29618

29619

29620

29621

29622

29623

29625

29626

29627

29628

29629

29630

29631

29633

29634

29635

29636

29637

29638

29639

29641

29642

29643

29644

29645

29646

29647

29649

29650

29651

29652

29653

29654

29655

29657

29658

29659

29660

29661

29662

29663

29665

29666

29667

29668

29669

29670

29671

29673

29674

29675

29676

29677

29678

29679

29681

29682

29683

29684

29685

29686

29687

29689

29690

29691

29692

29693

29694

29695

29697

29698

29699

29700

29701

29702

29703

29705

29706

29707

29708

29709

29710

29711

29713

29714

29715

29716

29717

29718

29719

29721

29722

29723

29724

29725

29726

29727

29729

29730

29731

29732

29733

29734

29735

Dimensions and specifications may be changed without prior notice.

F 24

FROR CEI 20-22 II

Technical data

Special PVC-sheath flexible cord as per


Italian standard CEI 20-22 II
Temperature range
flexing -5C to +70C
fixed installation -35C to +70C
Nominal voltage
U0/U 300/500 V = 1 mm
U0/U 450/750 V = 1,5 mm and above
Test voltage 2000 V
Insulation resistance
min. 20 MOhm x km
Radiation resistance
up to 80x106 cJ/kg (80 Mrad)
Minimum bending radius
approx. 10x cable

Cable construction

Bare copper conductor, fine wire stranded


to CEI 20-29 cl. 5
Special PVC compound Mi R 2
Colour coded up and to 4 cores to
HELUKABEL-JB colour code see Technical
Informations
As of 5 cores black with continuous white
number printing
Green-yellow earth core
Cores stranded in layers with optimal
lay-length
Special PVC outer sheath
Sheath colour grey, similar to RAL 7035,
with printing CEI 20-22 II

Properties

Oil- and petrol resistant as per CEI 20-22 II


Conditionally resistant to
Oil
Solvents
Acids
Lyes
PVC self-extinguishing and flame retardant,
test methods analog to IEC 60332-3
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

G = with green-yellow earth core.


AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application

Well known companies (FIAT, COMAU, etc.) use this cable for measurement and control purposes on machine tools and conveyors, as well
as on production lines in equipment production and for special mechanical engineering. These cables are used for flexible use for medium
mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open
air. Due to special conductor insulation- and sheath compound, this cable is flame resistant in case of fire and self-extinguishing. The good
oil- and petrol resistance allows the usage of this cable also in problem areas.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No.
60250
60251
60252
60253
60254
60255
60256
60284
60285
60257
60258
60259
.
60260
60261
60262
60263
60264
60265
60266
60267
60286
60268
60269
.

No.cores x
cross-sec.
mm
3G1
4G1
5G1
7G1
12 G 1
18 G 1
25 G 1
27 G 1
33 G 1
34 G 1
42 G 1
50 G 1
3 G 1,5
4 G 1,5
5 G 1,5
7 G 1,5
12 G 1,5
18 G 1,5
25 G 1,5
34 G 1,5
37 G 1,5
42 G 1,5
50 G 1,5

Outer
ca. mm
8,5
9,5
10,5
10,8
13,8
16,5
19,5
20,0
20,8
21,0
23,3
25,0

Cop.
weight
kg / km
29,0
39,0
48,0
67,0
115,0
173,0
240,0
259,0
317,0
326,0
405,0
480,0

9,6
11,0
12,0
12,5
16,0
18,8
23,0
26,0
26,5
29,5
30,5

43,0
58,0
72,0
101,0
173,0
259,0
360,0
490,0
533,0
605,0
720,0

Weight
AWG-No.
ca. kg / km
85,0
100,0
123,0
160,0
270,0
380,0
500,0
560,0
700,0
720,0
800,0
1050,0

17
17
17
17
17
17
17
17
17
17
17
17

105,0
150,0
190,0
220,0
350,0
515,0
705,0
990,0
1005,0
1080,0
1330,0

16
16
16
16
16
16
16
16
16
16
16

Dimensions and specifications may be changed without prior notice.

F 25

Part No.
60287
60270
60271
60272
60273
.
60274
60275
.
60276
.
60277
.
60278
.
60279
.
60280
.
60281
.
60282
.
60283

No.cores x
cross-sec.
mm
3 G 2,5
4 G 2,5
5 G 2,5
7 G 2,5
12 G 2,5

Outer
ca. mm
11,3
12,3
12,6
14,5
18,0

Cop.
weight
kg / km
72,0
96,0
120,0
168,0
288,0

4G4
7G4

14,0
16,0

Weight
AWG-No.
ca. kg / km
190,0
215,0
270,0
350,0
550,0

14
14
14
14
14

154,0
269,0

300,0
500,0

12
12

4G6

16,0

230,0

430,0

10

4 G 10

19,0

384,0

700,0

4 G 16

23,0

614,0

1000,0

4 G 25

28,0

960,0

1550,0

4 G 35

31,0

1344,0

2070,0

4 G 50

37,0

1920,0

2850,0

4 G 70

43,0

2688,0

4000,0

2/0

4 G 95

50,0

3648,0

5400,0

3/0

C.N.O.M.O

Type N0VV5-F according to NFC 32-207

Technical data

Special PVC based core insulation


As per to the french motor industry
standard for tool machines 04-24-22
Temperature range
flexing -5C to +80C
fixed installation -30C to +80C
Nominal voltage 500 V
Test voltage 2000 V
Insulation resistance
min. 20 MOhm x km
Radiation resistance
up to 80x106 cJ/kg (80 Mrad)
Minimum bending radius
15x cable

Cable construction

Plain copper conductors


Special core insulation
Cores laid up
Cores available in either red or black with
white figure imprint
Green-yellow earth core
PVC outer jacket grey

Properties

PVC self-extinguishing and flame retardant,


text method B and IEC 60332-1
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers
Resistant to
Oil
Petrol
Cutting oil according to C.N.O.M.O
recommendation E 03.40.150N

Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Further types and sizes available on
request.

Application

These cables are constructed specially for the french automobile industries and used for the installation in tool making machines, production
lines, industrial plants, air conditioning as well as for use in steel production. These cables are used for flexible use for medium mechanical
stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No.
60000
60001
60002
60003
60004
60005
60006
60007
60008
60009
60010
.
60011
60012
60013
60014
60015
60016
60017
60018
60019
60020
60021
.
60022
60023
60024
60025
60026
60027
60028
60029
60030
60031
60032
60033
.

No.cores x
cross-sec.
mm
2 x 0,75
3 G 0,75
4 G 0,75
5 G 0,75
6 G 0,75
12 G 0,75
18 G 0,75
27 G 0,75
36 G 0,75
48 G 0,75
60 G 0,75

Outer
ca. mm
6,2
6,6
7,2
8,0
8,9
11,6
13,9
17,2
19,7
22,8
24,9

Cop.
weight
kg / km
14,4
21,6
29,0
36,0
50,0
86,0
144,0
230,0
288,0
360,0
439,0

2x1
3G1
4G1
5G1
6G1
12 G 1
18 G 1
27 G 1
36 G 1
48 G 1
60 G 1

6,5
6,9
7,7
8,5
9,2
12,4
15,2
18,7
21,1
24,3
26,4

2 x 1,5
3 G 1,5
4 G 1,5
5 G 1,5
6 G 1,5
12 G 1,5
18 G 1,5
24 G 1,5
27 G 1,5
36 G 1,5
48 G 1,5
60 G 1,5

7,5
8,1
9,1
10,1
11,0
15,1
17,9
21,0
21,8
24,5
28,4
31,3

Weight
AWG-No.
ca. kg / km
50,0
59,0
72,0
87,0
105,0
175,0
267,0
404,0
503,0
670,0
805,0

18
18
18
18
18
18
18
18
18
18
18

19,0
29,0
38,0
48,0
67,0
115,0
192,0
308,0
384,0
480,0
586,0

56,0
72,0
84,0
104,0
124,0
219,0
314,0
485,0
620,0
809,0
1000,0

17
17
17
17
17
17
17
17
17
17
17

29,0
43,0
58,0
72,0
101,0
173,0
263,0
341,0
372,0
498,0
641,0
878,0

76,0
94,0
116,0
143,0
173,0
307,0
464,0
629,0
708,0
985,0
1175,0
1415,0

16
16
16
16
16
16
16
16
16
16
16
16

Part No.
60034
60035
60036
60037
60038
60039
.
60040
60041
60042
60043
.
60044
60045
60046
60047
.
60048
60049
60050
60051

No.cores x
cross-sec.
mm
2 x 2,5
3 G 2,5
4 G 2,5
5 G 2,5
6 G 2,5
12 G 2,5

Outer
ca. mm
10,5
11,0
12,0
13,1
15,0
18,0

Cop.
weight
kg / km
48,0
72,0
96,0
120,0
168,0
288,0

2x4
3G4
4G4
5G4

10,4
11,3
12,8
14,2

2x6
3G6
4G6
5G6
2 x 10
3 G 10
4 G 10
5 G 10

Weight
AWG-No.
ca. kg / km
122,0
151,0
191,0
244,0
292,0
524,0

14
14
14
14
14
14

77,0
115,0
154,0
192,0

178,0
230,0
300,0
362,0

12
12
12
12

11,6
12,7
14,2
15,7

115,0
173,0
230,0
288,0

218,0
325,0
481,0
584,0

10
10
10
10

15,0
16,6
18,4
20,9

194,0
288,0
384,0
480,0

505,0
610,0
736,0
913,0

8
8
8
8

Dimensions and specifications may be changed without prior notice.

F 26

JZ 604 TC TRAY CABLE

Technical data

PVC power cable to UL-standard 1277


TRAY CABLE
Multinorm
The TRAY CABLE also conforms to the
following standards:
(UL) MTW to UL-Std. 1063
AWM-Style 2587 to UL-Std. 758
(cUL) and CSA type TC FT4 to C22.2 no 230
CSA C22.2 No 210.2 I/II A/B 90C 600 V FT4
Temperature range
dry environment
flexing -5C to +90C
fixed installation -25C to +90C
wet environment
flexing -5C to +75C
fixed installation -25C to +75C
Nominal voltage to UL 600 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

PVC power cable, 90C, 600V

Cable construction

Bare copper, fine wire conductors,


according to DIN VDE 0295 cl. 5, BS 6360
cl. 5 and IEC 60228 cl. 5
Special PVC core insulation class 12 B to
table 50.155 UL-standard 1581,
type TFF to UL-Std. 62 table 6.2
(AWG 20-AWG 16),
type THHW to UL-Std. 83 table 5.2
(AWG 14)
Black cores with continuous white
numbering according to DIN VDE 0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-lengt
Special PVC outer sheath, to UL-Std. 1277
table 11.2
Sheath colour black (RAL 9005)

Properties

Material self-extinguishing and flame


retardant to UL-Standard 1277
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application

UL-approved, flexible high current cables for use up to 600 V, for all machines, tools and installation work. Suitable for use in dry, damp and
wet areas, outside, in cable ducts, open cable trays. Also inpipes, in the ground and for open installation in machinery and industrial areas.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No. No.cores x
cross-sec.
mm
69661
2x1
69662
3G1
69663
4G1
69664
5G1
69665
7G1
69666
9G1
69667
10 G 1
69668
12 G 1
69669
18 G 1
69670
25 G 1
69671
34 G 1
69672
50 G 1
.
69673
2 x 1,5
69674
3 G 1,5
69675
4 G 1,5
69676
5 G 1,5
69677
7 G 1,5
69678
8 G 1,5
69679
9 G 1,5
69680
10 G 1,5
69681
12 G 1,5
69682
16 G 1,5
69683
18 G 1,5
69684
25 G 1,5
69685
34 G 1,5
69686
41 G 1,5
69687
50 G 1,5
69688
61 G 1,5
.

AWG-no.

Outer
ca. mm

18
18
18
18
18
18
18
18
18
18
18
18

8,0
8,4
9,1
10,0
11,7
12,6
14,3
14,7
17,1
20,3
23,7
26,1

Cop.
weight
kg / km
19,2
29,0
39,0
48,0
67,0
84,0
96,0
115,0
173,0
240,0
326,0
480,0

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

8,4
8,8
9,6
10,5
12,3
13,3
13,3
15,1
15,6
17,1
18,2
22,7
25,3
26,7
27,3
29,4

28,8
43,0
58,0
72,0
101,0
115,0
130,0
144,0
173,0
230,0
259,0
360,0
489,0
590,0
720,0
878,0

Weight
ca. kg / km

91,0
105,0
122,0
147,0
192,0
213,0
261,0
294,0
331,0
402,0
430,0
597,0
714,0
803,0
1021,0
1238,0

74,0
87,0
99,0
117,0
151,0
172,0
206,0
260,0
371,0
481,0
551,0
959,0

Dimensions and specifications may be changed without prior notice.

F 27

Part No. No.cores x


cross-sec.
mm
69689
2 x 2,5
69690
3 G 2,5
69691
4 G 2,5
69692
5 G 2,5
69693
7 G 2,5
69694
8 G 2,5
69695
9 G 2,5
69696
10 G 2,5
69697
12 G 2,5
69698
18 G 2,5
69699
25 G 2,5
.
69700
3G4
69701
4G4
69702
5G4
69703
7G4
69704
9G4
69705
12 G 4
69706
18 G 4
.
69707
3G6
69708
4G6
69709
5G6
69710
7G6
.
69711
3 G 10
69712
4 G 10
69713
5 G 10
69714
7 G 10
.

AWG-no.

Outer
ca. mm

14
14
14
14
14
14
14
14
14
14
14

9,4
9,9
10,8
11,8
14,7
16,0
16,0
17,1
17,7
20,8
25,8

Cop.
weight
kg / km
48,0
72,0
96,0
120,0
168,0
192,0
216,0
240,0
288,0
432,0
600,0

Weight
ca. kg / km

12
12
12
12
12
12
12

11,0
12,0
13,2
16,5
17,8
19,9
24,2

115,0
154,0
192,0
269,0
346,0
461,0
691,0

190,0
229,0
284,0
394,0
480,0
841,0
981,0

10
10
10
10

12,5
14,5
15,8
17,3

173,0
230,0
288,0
403,0

290,0
384,0
468,0
654,0

8
8
8
8

16,9
18,6
20,4
23,5

288,0
384,0
480,0
672,0

511,0
587,0
784,0
970,0

111,0
140,0
161,0
194,0
257,0
339,0
341,0
392,0
470,0
682,0
891,0

Continuation

JZ 604 TC TRAY CABLE


Part No. No.cores x
cross-sec.
mm
69715
3 G 16
69716
4 G 16
69717
5 G 16
69718
7 G 16
.
69719
3 G 25
69720
4 G 25
69721
5 G 25
69722
7 G 25
.
69723
3 G 35
69724
4 G 35
69725
5 G 35
.
69726
3 G 50
69727
4 G 50
69728
5 G 50
.

AWG-no.

Outer
ca. mm

6
6
6
6

21,0
23,9
26,3
28,8

Cop.
weight
kg / km
461,0
614,0
768,0
1075,0

Weight
ca. kg / km

4
4
4
4

24,9
27,2
30,3
33,1

720,0
960,0
1200,0
1680,0

1090,0
1421,0
1611,0
1943,0

2
2
2

27,1
29,8
33,0

1008,0
1344,0
1680,0

1734,0
2011,0
2347,0

1
1
1

33,2
36,7
41,5

1440,0
1920,0
2400,0

2041,0
2539,0
2894,0

651,0
869,0
1117,0
1364,0

PVC power cable, 90C, 600V


Part No. No.cores x
cross-sec.
mm
69729
3 G 70
69730
4 G 70
69731
5 G 70
.
69732
3 G 95
69733
4 G 95
69734
5 G 95
.
69735
3 G 120
69736
4 G 120
69737
5 G 120

AWG-no.

Outer
ca. mm

2/0
2/0
2/0

37,6
42,0
47,6

Cop.
weight
kg / km
2016,0
2688,0
3360,0

Weight
ca. kg / km

3/0
3/0
3/0

41,8
47,0
52,5

2736,0
3648,0
4560,0

5010,0
6104,0
7891,0

4/0
4/0
4/0

46,0
51,5
56,5

3456,0
4608,0
5760,0

5940,0
7604,0
8751,0

2831,0
3494,0
4260,0

Dimensions and specifications may be changed without prior notice.

F 28

JZ 604-FCY TC TRAY CABLE PVC power cable, screened, 90C,

600V, EMC-preferred type

Technical data

PVC power cable, screened


toUL-standard 1277 TRAY CABLE
Multinorm
(UL) MTW to UL-Std. 1063
AWM-Style 2587 to UL-Std. 758 (cUL) and
CSA type TC FT4 to C22.2 no 230, CSA C22.2
No 210.2 I/II A/B 90C 600 V FT4
Temperature range
dry environment
flexing -5C to +90C
fixed installation -25C to +90C
wet environment
flexing -5C to +75C
fixed installation -25C to +75C
Nominal voltage to UL 600 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
10x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Cable construction

Bare copper, fine wire conductors,


according to DIN VDE 0295 cl. 5, BS 6360
cl. 5 and IEC 60228 cl. 5
Spezial PVC core insulation class 12 B to
table 50.155 UL-standard 1581,
type TFF to UL-Std. 62 table 6.2 (AWG
20-AWG 16),
type THHW to UL-Std. 83 table 5.2 (AWG
14)
Black cores with continuous white
numbering according to DIN VDE 0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-lenght
Special separation foil
Tinned copper braided screening, approx.
85% coverage
Special PVC outer sheath, to UL-Std. 1277
table 11.2
Sheath colour black (RAL 9005)

Properties

Material self-extinguishing and flame


retardant to UL-Standard 1277
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
To optimise the EMC features we
recommend a large round contact of the
cooper braiding on both ends.

Application

UL-approved, flexible high current cables for use up to 600 V, for all machines, tools and installation work. Suitable for use in dry, damp and
wet areas, outside, in cable ducts, open cable trays. Also in pipes, in the ground and for open installation in machinery and industrial areas.
EMC = Electromagnetic compatibillity
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No. No.cores x
cross-sec.
mm
69750
2x1
69751
3G1
69752
4G1
69753
5G1
69754
7G1
69755
9G1
69756
10 G 1
69757
12 G 1
69758
18 G 1
69759
25 G 1
69760
34 G 1
69761
50 G 1
.
69762
2 x 1,5
69763
3 G 1,5
69764
4 G 1,5
69765
5 G 1,5
69766
7 G 1,5
69767
8 G 1,5
69768
9 G 1,5
69769
10 G 1,5
69770
12 G 1,5
69771
16 G 1,5
69772
18 G 1,5
69773
25 G 1,5
69774
34 G 1,5
69775
41 G 1,5
69776
50 G 1,5
69777
61 G 1,5
.

AWG-no.

Outer
ca. mm

18
18
18
18
18
18
18
18
18
18
18
18

8,6
9,0
9,7
10,5
12,2
13,2
15,0
15,4
17,8
21,1
24,5
26,2

Cop.
weight
kg / km
51,2
76,4
102,9
126,4
204,8
269,8
304,7
331,1
494,7
642,1
807,6
892,1

16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16

9,0
9,4
10,2
11,1
12,9
14,5
14,5
15,8
16,2
17,9
18,9
22,3
24,9
26,7
33,7
36,0

78,3
114,2
152,1
189,2
279,4
308,6
326,8
401,6
491,7
526,1
749,1
1011,4
1214,7
2060,6
3040,8
3416,1

Weight
ca. kg / km

161,0
181,0
240,0
274,0
367,0
431,0
437,0
511,0
598,0
630,0
787,0
1240,0
1401,0
2671,0
3614,0
4089,0

151,0
164,0
200,0
229,0
306,0
371,0
411,0
460,0
624,0
845,0
984,0
1096,0

Dimensions and specifications may be changed without prior notice.

F 29

Part No. No.cores x


cross-sec.
mm
69778
2 x 2,5
69779
3 G 2,5
69780
4 G 2,5
69781
5 G 2,5
69782
7 G 2,5
69783
8 G 2,5
69784
9 G 2,5
69785
10 G 2,5
69786
12 G 2,5
69787
18 G 2,5
69788
25 G 2,5
.
69789
3G4
69790
4G4
69791
5G4
69792
7G4
69793
9G4
69794
12 G 4
69795
18 G 4
.
69796
3G6
69797
4G6
69798
5G6
69799
7G6
.
69800
3 G 10
69801
4 G 10
69802
5 G 10
69803
7 G 10

AWG-no.

Outer
ca. mm

14
14
14
14
14
14
14
14
14
14
14

10,0
10,5
11,4
12,4
15,3
16,5
16,5
17,9
18,4
22,4
26,5

Cop.
weight
kg / km
128,4
189,5
250,1
314,2
464,3
490,9
498,6
511,6
764,1
1120,4
1714,0

Weight
ca. kg / km

12
12
12
12
12
12
12

11,6
12,6
14,5
17,1
18,4
20,5
25,0

304,2
402,7
514,2
721,2
849,3
1211,8
1714,9

381,0
504,0
692,0
908,0
1104,0
1497,0
2104,0

10
10
10
10

13,8
15,1
16,4
18,0

457,2
608,6
763,9
1002,8

623,0
729,0
1082,0
1414,0

8
8
8
8

17,6
19,3
22,1
24,2

796,7
1029,6
1273,8
1696,2

1108,0
1324,0
1596,0
2186,0

269,0
294,0
341,0
420,0
551,0
583,0
593,0
631,0
847,0
1336,0
1921,0

JZ 604-YCY TC TRAY CABLE PVC power cable, screened, 90C,

600V, EMC-preferred type

Technical data

PVC power cable, screened to


UL-standard 1277 TRAY CABLE
Multinorm The TRAY-CABLE also conforms
to the following standards:
(UL) MTW to UL-Std. 1063 AWM-Style 2587
to UL-Std. 758
(cUL) and CSA type TC FT4 to C22.2 no 230,
CSA C22.2 No 210.2 I/II A/B 90C 600 V FT4
Temperature range
dry environment
flexing -5C to +90C
fixed installation -25C to +90C
wet environment
flexing -5C to +75C
fixed installation -25C to +75C
Nominal voltage to UL 600 V
Test voltage 3000 V
Breakdown voltage min. 6000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
10x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Cable construction

Bare copper, fine wire conductors,


according to DIN VDE 0295 cl. 5, BS 6360
cl. 5 and IEC 60228 cl. 5
Spezial PVC core insulation class 12 B to
table 50.155 UL-standard 1581,
type TFF to UL-Std. 62 table 6.2 (AWG
20-AWG 16),
type THHW to UL-Std. 83 table 5.2 (AWG
14)
Black cores with continuous white
numbering according to DIN VDE 0293
Green-yellow earth core in the outer layer
(3 cores and above)
Cores stranded in layers with optimal
lay-lenght
PVC-inner sheath, to UL-Std. 1277
table 11.2
Tinned copper braided screening, approx.
85% coverage
Special PVC outer sheath, to UL-Std. 1277
table 11.2,
Sheath colour black (RAL 9005)

Properties

Material self-extinguishing and flame


retardant to UL-Standard 1277
The materials used in manufacture are
cadmium-free and contain no silicone and
free from substances harmful to the
wetting properties of lacquers

Note

G = with green-yellow earth core;


x = without green-yellow earth core (OZ).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application

UL-approved, flexible high current cables for use up to 600 V, for all machines, tools and installation work. Suitable for use in dry, damp and
wet areas, outside, in cable ducts, open cable trays. Also in pipes, in the ground and for open installation in machinery and industrial areas.
EMC = Electromagnetic compatibillity
To optimise the EMC features we recommend a large round contact of the cooper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Part No. No.cores x
cross-sec.
mm
69804
3 G 16
69805
4 G 16
69806
5 G 16
69807
7 G 16
.
69808
3 G 25
69809
4 G 25
69810
5 G 25
69811
7 G 25
.
69812
3 G 35
69813
4 G 35
69814
5 G 35
.
69815
3 G 50
69816
4 G 50
69817
5 G 50
.

AWG-no.

Outer
ca. mm

6
6
6
6

25,2
27,8
31,2
34,5

Cop.
weight
kg / km
1245,1
1655,2
2063,6
2886,5

Weight
ca. kg / km

4
4
4
4

29,0
32,4
34,2
40,3

1932,0
2561,1
3140,2
4481,7

2455,0
2721,0
3490,0
4960,0

2
2
2

32,4
36,2
40,5

2504,7
3320,8
4180,8

3130,0
4100,0
4921,0

1
1
1

40,4
45,5
50,0

3520,1
4821,7
5820,8

4560,0
5761,0
7186,0

1385,0
1861,0
2614,0
3211,0

Part No. No.cores x


cross-sec.
mm
69818
3 G 70
69819
4 G 70
69820
5 G 70
.
69821
3 G 95
69822
4 G 95
69823
5 G 95
.
69824
3 G 120
69825
4 G 120
69826
5 G 120

AWG-no.

Outer
ca. mm

2/0
2/0
2/0

47,1
51,1
56,0

Cop.
weight
kg / km
5020,1
6620,3
8420,4

Weight
ca. kg / km

3/0
3/0
3/0

50,1
55,0
60,5

6724,3
9100,0
10940,1

8520,0
10200,0
13800,0

4/0
4/0
4/0

54,0
59,5
64,5

8620,7
11420,0
12940,4

11090,0
13620,0
15420,0

5580,0
7387,0
9290,0

Dimensions and specifications may be changed without prior notice.

F 30