You are on page 1of 67

Confidential

MMBS Installation Guide < Sprint >

2011. 3. 2011 3 25 H/W Infra Lab.

Annotation) This data could be revised while designing in detail.

1. System Description
Confidential
Items System Type Frequency Sector Channel BW (MHz) MMBS Outdoor 800MHz, 1.9GHz, 2.5GHz, 2.5GHz @ RRU Max. 4 RRU/ sector (Total 12 RRU max) 7MHz (800M), 65MHz(1 9G) 20MHz(2 5G) (800M) 65MHz(1.9G), 20MHz(2.5G) BBU Cabinet : - (kg) w/o DU shelf - (kg) with 4 DU shelf Battery Cabinet : - (kg) w/o battery - (kg) with battery T1 or M/W or optic Specification

Weight

Network Interface

Physical Dimensions 1800x700x1018(820) mm / 70.8in x 29.5in x 40.1(37.0)in 800 00 0 8(8 0) 08 95 0 (3 0) (HxWxD) (H W D) 220VAC (22A,max) @ w/o battery,Only CDMA 220VAC (36A,max) @ w/o battery,CDMA/LTE/WiMAX Power Consumption 220VAC (40A,max) @ with battery, Only CDMA 220VAC (80A ma ) @ with batter CDMA/LTE/WiMAX (80A,max) ith battery, DU-RU Interface CPRI 4.0 specification (Optic)

Note. Note Recommended NFB Capacit 100A ma 1EA Capacity 100A,max.

Rectifier module Specification


Items
Voltage Range Frequency Output Voltage O t t V lt Output Voltage Range y Efficienty Maximum Output Power Weight 185~275VAC 45~66 Hz(50/60 Hz) -53.5 VDC 53 5 -43.5~-57.6VDC 96% @ 2kW Output,module % p , 2,000W x 7 @ 25 1.950 kg (4.3lbs)

Confidential
Specification

Battery

Confidential

1.1 System configuration


Confidential
BBU cabinet Battery cabinet

PDP Rectifier
Battery

WiMAX TD-LTE/FDD LTE CDMA CDMA/FDD LTE


Battery

Old version

User space

User Space
Battery

Cabling Space

Cabling Space

Battery

[BBU Cabinet]

[Battery Cabinet]

Confidential
<66Block> - Maker : - P/N :

GPS port

Mudroom

<Comseal> - Maker : Roxtec - P/N : ComSeal 16/16

2 2 Conduit 5 4 3 2 1 0 <GPS Splitter> - Maker : Symmetricom - P/N : 58536A

[Mudroom] [Back side of the BBU cabinet]


Note. This data could be revised while designing in detail.

1.2 System Dimension


BBU Cabinet Confidential

700.0 700 0

1,018.0 1 018 0

[Front View]

[Left View]

[Rear View]
6

300.0

433.0

1,80 00.0

Battery Cabinet

Confidential

Old version

Old version

742.5 700.0 700 0 1,022.3 1 022 3

[Front View]

[Left View]
7

1,800.0

1.3 Floor Layout


Confidential

min. distance for no colision opening cabinets

959.8

60

1225.5

1,460min

Confidential

2,209 9.5

959.8

60

1,460 min 1,739.8 min

Confidential

670.0 0

630.0

[Power/Battery Cabinet Anchor Location] / C


10

1.4 Service Area


700.0 700 0 60.0 60 0 700.0 700 0

Confidential

Mudroom

743.0

Battery

60 System 2,209.5

1,447.5

136 61.0

1,123.4

760.0

762.0

11

1.5 Environment Control Module & Sensor


Confidential

Fire Sensor Door Switch Lamp

Fire Sensor Door Switch Lamp

User Space

Cabling Space Flood sensor Flood sensor

[BBU Cabinet]

[Batery Cabinet]

12

1.6 External I/F Cable(BBU cabinet)


Confidential
Item
Power (AC)

Cable
1P3W, L1/L2 /N : AWG 2 Black/Red/White AWG 1/0 Black/Blue SFTP,4p

Connector
NFB terminal

Terminal name
L1,L2,N Conduit #1

Qt
1

Provider
STA

Battery Power #0a (Battery) CAN bus #0(Battery)

Compression terminal,1H, M8 RJ-45 Ferrule Compression terminal,1H, M8 , , RJ-45 Ferrule

Battery switch

Conduit #0

Eltek

Conduit #0 Conduit #0 Battery switch Conduit #5

1 1 2

Eltek Eltek Eltek

DC Power #0b(Battery) AWG 12 Battery Power #1a ( (Battery) y) CAN bus #1(Battery) AWG 1/0 Black/Blue SFTP,4p

Conduit #5 Conduit #5

1 1

Eltek Eltek

DC Power #1b(Battery) AWG 12

RRU cable

Hybrid, Option

Power,bare wire Optic,LC

Conduit # 2,3,4 Mudroom, Comseal C l

HQ

Backhaul(T1) User Define Alarm GPS Ground

Shield type Shield type LMR-400 AWG 2

RJ-45, wire Bare wire N-Male or N-Female Compression terminal,2H, M6, L5/8 terminal 2H M6 L5/8

Surge protector 66 block GPS arrestor Ground bus bar

16max 1 1

STA STA STA STA

Conduit #1

13

1.7 I/F Port Position


Confidential

Battery Power terminal AC terminal

Battery operating power terminal

RRU DC P Power RRU Optic

User Space

CAN BUS Cabling Space Ground

CAN BUS

[BBU Cabinet]

[Batery Cabinet]

14

Confidential

UDA,Backhaul

GPS port

Mudroom

< Comseal > - Maker : Roxtec - P/N : ComSeal 16/16

2 2 Conduit 5 4 3 2 1 0 UDA or Link cable GPS cable

[Mudroom] [Back side of the BBU cabinet]


Note. This data could be revised while designing in detail.

15

1.8 Power Blockdiagram


System Power Blockdiagram Confidential

PE

16

Battery Cabinet Power Blockdiagram

Confidential

Check power supply TN-C in USA 1P3,can it use 2 SPD(L to N) ?

17

Load Breaker

Confidential

N o C a p ac ity

F 1 1 6 A

F 2 1 6 A

F 3 1 6 A

F 4 1 6 A

F 5 1 6 A

F 6 1 6 A

F 7 1 6 A

F 8 1 6 A

F 9 1 6 A

F 1 0 2 0 A

F 1 1 1 6 A

F 1 2 1 6 A

F 1 3 1 6 A

F 1 4 2 0 A

F 1 5 1 6 A

F 1 6 1 6 A

F 1 7 1 6 A

F 1 8 2 0 A

F 1 9 4 A

F 2 0 4 A

F 2 1 2 A

F 2 2 2 A

F 2 3 2 A

F 2 4

AUX Label AUX0 AUX1 DU#0

UADU RRU#0 RRU#1 RRU#2 RRU#3 RRU#4 RRU#5 DU#1 DU#2 DU#3

RRU RRU#10 RRU#11 FAN #1 RRU#6 RRU#7 1.9 9GHz RRU#8 RRU#9 FAN#2 Smoke EAIU Light

1.9 9GHz

1.9 9GHz LVLD LVBD

Coldstart contactor

18

Ref. Power distribution system at US


Confidential

19

2.1 SOW
Confidential

GPS Antenna Lightning rod BBU Cabinet RRU

Aux. Equip.

Mudroom

Backhaul UDA

AC Power Distribution Panel Tower

AC220V

Ground

Battery Cabinet

Ground

20

2.2 Material List


Confidential

To be defined.

21

3. Installation Process
Confidential

Material Check

Ground Cable

DU Installation

Backhaul Cable

Ground Buss Installation

AC Power Cable

EAIU Installation

UDA Cable (Option)

BBU Cabinet Anchoring

Backup Battery Cable

GPS Arrestor& Splitter

GPS Cable

Battery Cabinet Anchoring

AUX Installation (Option)

RRU Cable

Check RRU Installation

22

Confidential
Antenna

RRU
RF Antenna Cable Frame Ground Cable

Power DC Cable GPS Antenna Cable Optic Cable

User Space Cablin g Space


Power Cable (FR-8 25 mm2 3C, 1ea) AC Distribution Panel Ground Cable(GV 25 mm2 1C) Main Ground Bar

23

Confidential

PDP Rectifier WiMAX TD-LTE/FDD LTE CDMA CDMA/FDD LTE

User Space

Cabling Space Battery cable AC cable hybrid cable

[Front View]

24

Confidential

Conduit No. 0 1 2

Usage Battery #0 AC/Ground RRU Alpha RRU Beta RRU Gamma Battery #1 UDA or Link cable GPS cable

5
To RRU

3 4 5

[Mudroom]

[Rear View]

25

3.1 Anchoring
Confidential

670.0

630.0

[Power/Battery Cabinet Anchor Location]


26

Confidential

Anchor Bolt

Nut Spring Washer Plane Washer

Floor

2.76

(M10 Anchor-Bolt)

Completion of Anchoring C f

Each equipment requires specific bolting pattern. Verify that you have the right bolt pattern. pattern pattern

27

3.2 Ground Cable


Confidential

(Front view)

User Space

25 mm2 Pressure Terminal (ST, M6,2hole, Dist: 5/8)

Cabling C bli Space

28

3.3 AC Power Cable


Confidential

AC
(Front view)

100A, 1P3W L1/L2/N

User Space

Power Cable P C bl AC : L1/L2/N (BLACK/RED/WHITE)

Cabling C bli Space

1) Through the conduit #1 2) Connect Ferrule to wire and Fix the cable with switch screw .

29

3.4 Backup Battery Cable


Confidential
Battery power switch

Routing path : Left,rear edge Battery Batter

Battery
(Front view)

Battery operating power terminal

CAN BUS

User Space Battery CAN BUS

User Space

Cabling Space Battery

Cabling C bli Space

[Battery Cabinet]

[BBU Cabinet]

30

Confidential

(Front view)

User Space

Cabling C bli Space

31

3.5 UADU installation


Confidential
1) Install DU shelf support bracket at 20U with cage nut(M6) 2) Install DU shelf upper side of bracket stackable 3) Tag the DU shelf label 4) Connect DU shelf cable (power,GPS,Backhaul,Alarm) (power GPS Backhaul Alarm)

Power switch

UADU

(Front view)

Bracket

DU shelf bracket

User Space

User Space

Cabling Space

Cabling Space

[BBU Cabinet]

32

Confidential Step.1 DU Blank bracket Install

Example .

1) Fix the bracket at 20U from bottom Mounting frame with M6 Cage nuts

33

Confidential Step.2 UADU Install


Step.2-1 Step 2-1 UADU Ground cable connection
Detail A M6 SEMS DU Unit backside

4 mm2 Pressure Terminal (d2: 16 mm, 2Hole)

Heat Shrink Tube (Green)

Ground Cable (AWG10, GV 4 mm2 1C)


Detail B

first connect the Ground cable before install DU unit

1) Connect ground cable backside of UADU ) g 2) Fix the UADU upper DU blank bracket with M6 floating nuts 3) Connect the other ends of ground cable at ground bar of the cabinet left bottom . 34

Confidential
Step.2-2 UADU install

M6 SEMS

Cage nut

Step.2-3 Ground cable - frame

Ground Cable(AWG10, GV 4 mm2 1C)

Heat Shrink Tube(Green) 4 mm2 Pressure Terminal (LUg Type, 2Hole) M6 Hex. Nut Ground Bar

35

Power Cable SPEC. from Rectifier to UADU

Confidential

A2: RTN

D-Sub Plastic hood

A1: -48 VDC

SPEC Cable Power Cable Color (CV 2.5 mm2 1C-2) ( ) D-Sub Connector(2W2C)302W2CPXX42A10X & Hood -

Wire Color A1(-48VDC: blue) A2(RTN: red) ( ) CONEC

Maker

Connector

36

3.6 EAIU4-U Installation


Confidential
UDA

Ethernet

(Front view)
Switch

User Space

UDE

Power

Cabling Space

1) Re-assemble the wing brackets of EAIU as picture. 2) Fix EAIU at the right frame with M6 SEMS 2ea as picture M6,SEMS

37

Cable SPEC. from Rectifier to EAIU

Confidential

SPEC Cable Connector SEC CODE : EP39-01736A UL2464, AWG20, UL2464 AWG20 2C BLK 51067-0300 Black -

Wire Color

Maker Korea Maker MOLEX

38

3.7 Surge protector Installation


Confidential

GPS splitter

GPS arrestor

(Rear view)

Mudroom

Roxtec Comseal

[Mudroom]

Note. It will add the surge protector for T1 .

39

3.8 Auxillary Unit Installation


Confidential
* To be defined.

Power switch

UADU

(Front view)

Bracket

DU shelf bracket

User Space

User Space

Cabling Space

Cabling Space

[BBU Cabinet]

40

3.9 Backhaul When T1


Confidential

66 Block

GPS splitter

GPS arrestor

(Rear view)

Mudroom

UDA or Link cable

Roxtec Comseal

[Mudroom]

Note. It will add the surge protector for T1 .

41

Confidential

Note. BH did not Final Confirmed

BH
(Front view)

User Space

T1 (from Cell Site Router. Install at User space )

Cabling Space

1) Link the cable from UDE port of UADU to CSR. 2) Link T1 cable from CSR to surge protector at mudroom mudroom.

42

T1 cable SPEC. from DU to CSR

Confidential

* Pin MAP
RJ45 PLUG Shield type Pin No. S-FTP 1 2 3 4 5 6 7 8 Tip Ti Rimg Tx+ T TxTip Ring Rx+ RxPair Description COLOR MAP WHITE /ORANGE ORANGE WHITE /GREEN BLUE WHITE /BLUE GREEN WHITE /BROWN BROWN

SPEC Cable Connector C t SEC CODE : EP39S-FTP, CAT5e RJ45 PLUG (Shi ld) (Shield) -

Wire Color -

Maker

43

3.10 UDA cable


Confidential
UDA_EAIU ALARM_CABINET 66 Block

(Rear view)

Mudroom

Roxtec Comseal UDA or Link cable

[Mudroom]
1) Pin map is not defined. 2) T1 surge protector spec. is not confirmed. 44

Confidential

SMART PACK_REC PACK REC

Mudroom

UDE
(Front view)

UDE

UDE
User Space

2A_PDP

UDE

Cabling Space

[EAIU4-U]

45

66 Block Pin Map


Conne Pin ctor No. 1 2 3 4 5 6 7 8 9 10 11 12 66 13 Block 14 15 16 17 18 19 20 21 22 23 24 25 Primary Color Map Secondary Pin No. 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Primary Color Map

Confidential

Secondary

To be defined.

46

Cable SPEC. from EAIU to 66 block

Confidential

SPEC Cable Connector SEC CODE : EP39-01555A UL2919, AWG24, UL2919 AWG24 20PR 10136-3000ve -

Wire Color 3M

Maker

47

Cable SPEC. from DU to EAIU/SpartPack

Confidential

* Pin MAP
RJ45 PLUG Shield type Pin No. 1 2 3 4 5 6 7 8 Pair TX0+ TX0RX0+ TX1+ TX1RX0RX1+ RX1Description Ethernet TX Positive signal Ethernet TX Negative signal Ethernet RX Positive signal Ethernet TX Positive signal(Gigabit) Ethernet TX Negative signal(Gigabit) Ethernet RX Negative signal Ethernet RX Positive signal(Gigabit) Ethernet RX Negative signal(Gigabit) COLOR MAP WHITE /ORANGE ORANGE WHITE /GREEN BLUE WHITE /BLUE GREEN WHITE /BROWN BROWN

S-FTP

SPEC Cable Connector S FTP, S-FTP, CAT5e RJ45 PLUG (Shield) -

Wire Color -

Maker

SEC CODE : EP39-01342B

48

Cable SPEC. from SpartPack to Mudroom

Confidential

* Pin MAP
Pin No. 1 2 3 4 5 6 7 8 Pair Description COLOR MAP

To be defined

SPEC Cable Connector SEC CODE : EP39S FTP, S-FTP, CAT5e -

Wire Color -

Maker

49

3.11 GPS Cable


Confidential

GPS plitter

GPS arrestor

(Rear view)

Mudroom

Roxtec Comseal

[Mudroom]
1) GPS surge protector spec. is not confirmed. 50

GPS Cable at UADU

Confidential

WiMAX Only

LTE Only

(Front view)

CDMA Only

CDMA + LTE
User Space

Cabling Space

1) Cable route GPS Splitter from Mudroom 51

Cable SPEC. from GPS Arrestor to Splitter

Confidential

To be defined
SPEC Cable Connector SEC CODE : EP39-A Wire Color Maker

Cable SPEC. from Splitter to UADU

To be defined
SPEC Cable Connector SEC CODE : EP39-A Wire Color Maker

52

3.12 RRU Cable


RRU Power(Lab. Certi.) Confidential

Table. Pin map


2.5GHz 2 5GHz gam beta ahph a -48V -48V -48V V RTN RTN RTN N 2.5GHz 2 5GHz -48V -48V -48V V RTN RTN RTN N 800MHz -48V -48V -48V V RTN RTN RTN N 1.9GHz 1 9GHz -48V -48V -48V V RTN RTN RTN N

(Front view)

-48V

Power Cable(AWG 6~10) -48V : Blue RTN : Black User Space

Cabling Space

1) Through the conduit #2, #3, #4 2) Connect Ferrule to wire and Fix the cable with switch screw.

53

RRU Modified Power Cable (FIT&Commercial)


Table. Pin map p

Confidential

2.5 2.5 800 1.9 2.5 2.5 800 1.9 2.5 2.5 800 1.9 GHz GHz MHz GHz GHz GHz MHz GHz GHz GHz MHz GHz RTN -48V RTN -48V RTN -48V RTN -48V RTN -48V RTN -48V RTN -48V RTN -48V RTN -48V RTN -48V RTN -48V RTN -48V alpha beta gamma Power Cable(AWG 6~10) -48V : Blue RTN : Black Move SPD position Changing.. Changing

(Front view)

DCSPDBlock DC SPD Block


User Space

Cabling Space

1) Through the conduit #2, #3, #4 2) Connect Ferrule to wire and Fix the cable with switch screw 54

Optic cable

Confidential

WiMAX Only

LTE Only

(Front view)

CDMA Only

CDMA + LTE
User Space

Cabling Space

1) Through the conduit #2, #3, #4 2) Connect suitable optic cable 55

Ref. Conduit finishing method


Confidential
[Optic cable storage box]

It can use storage box when the Optic cable is long

If Power cable is long , Cut the power cable. And Connect Ferrule to wire

2 Conduit Optic cable Power cable

Cable gland or Butyl

Hybrid cable < 1m [BBU Cabinet Right view]

Flexible pipe length can be changeable. It is why waterproof .

56

Ref. Hybrid cable type (sort by length)


Confidential
Table. Cable Type
Type 1 T
Total Length ~40m

Type 2 T
~70m

Type 3 T
~120m (requirement is 300feet = 91.4m) AWG 4 1 pair, i AWG 6 3 pair 36mm 900mm LC/PC-to-LC/PC Single mode AWG 4 -> AWG 6 conversion kit need AWG 10, 4 pair 2 pair power and optic cable With PE pipe

Hybrid P H b id Power C bl Cable configuration Cable diameter Bending radius Optic cable BBU cabinet (power cable terminal max size AWG 6 ) RRU Power cable Spec Non use Power and optic cable protection

AWG 8 1 pair, i AWG 10 3 pair 32mm 800mm LC/PC-to-LC/PC Single mode -

AWG 6 1 pair, i AWG 8 3 pair 32mm 800mm LC/PC-to-LC/PC Single mode -

AWG 10, 4 pair 2 pair power and optic cable With PE pipe

AWG 10, 4 pair 2 pair power and optic cable With PE pipe

Note. SAMSUNG FIBEROPTICS. 57

[Type 1] 30m Hybrid Cable


Confidential
length : 2.5m
AWG #8 AWG #10 5.5mm

[1.9Mhz] Power cable AWG #8, 2C Optic cable LC/PC * 4ea + spare 1ea

1900MHz

5 core optic

Max : 41mm

To BBU Cabinet

AWG #10

800MHz & 2.5Ghz


Break out point Cable C bl AWG #6 #8 #6, converte AWG #10

[800Mhz & 2.5Ghz] Power cable : AWG #10 , 2C Optic cable : LC/PC * 4ea + spare 1ea

800MHz & 2.5Ghz

[Future Used]
Water-proof Cap C

800MHz 800MH & 2.5Ghz

length : 5m
[Future Used]
[ Cable AWG convertor] All Power cable : AWG #10 , 2C * 4ea

[Type 2] 60m Hybrid Cable


Confidential
length : 2.5m
AWG #6 AWG #10 5.5mm

[1.9Mhz] Power cable AWG #6, 2C Optic cable LC/PC * 4ea + spare 1ea

1900MHz

5 core optic

Max : 41mm

To BBU Cabinet

AWG #8

800MHz & 2.5Ghz


Break out point Cable C bl AWG #6 #8 #6, converte AWG #10

[800Mhz & 2.5Ghz] Power cable : AWG #8 , 2C Optic cable : LC/PC * 4ea + spare 1ea

800MHz & 2.5Ghz

[Future Used]
Water-proof Cap C

800MHz 800MH & 2.5Ghz

length : 5m
[Future Used]
[ Cable AWG convertor] All Power cable : AWG #10 , 2C * 4ea

[Type 3] 90m Hybrid Cable


AWG #4 -> #6 ferulle * 2ea

Confidential
length : 2.5m
AWG #4 5.5mm

[1.9Mhz] Power cable AWG #4, 2C Optic cable LC/PC * 4ea + spare 1ea

1900MHz

5 core optic

Max : 41mm

To BBU Cabinet

AWG #6

800MHz & 2.5Ghz


Break out point Cable C bl AWG #4 , #6 converte AWG #10

[800Mhz & 2.5Ghz] Power cable : AWG #6 , 2C Optic cable : LC/PC * 4ea + spare 1ea

x3

800MHz & 2.5Ghz

[Future Used]
Water-proof Cap C

800MHz 800MH & 2.5Ghz

length : 5m
[Future Used]
[ Cable AWG convertor] All Power cable : AWG #10 , 2C * 4ea

Ref. Hybrid cable length


Confidential

2sector 2 t

1sector 5.0m Cable length is changed by the RRU location.

2.5m 2 5m Grounding User Space X1 3sector X2 Need the RRU height but Tower height.

Cabling Space

Cable length = X1 + X2
61

RRU cable connection (example)


There are 3 Type RRU . RU cabling window Figure differ 3RRU .

Unit: mm

Confidential

Depending RRUs Depending RRUs

Depending RRU D di RRUs

< Cable Gland > Maker : PFLITSCH http://www.pflitsch.de/ P/N : 22052y, 13 (M20, 13 ~ 9mm)
SHOT BOOT

< RRU >


56 AWG10 200(Max)

20(max)

insulator
Insulator color -48V( blue ) GND( red )

Optic core No. :5


Bending radius =R 20

120.5
5.50.5

< Power Cable >


Note. This picture is similar sample

< Optic Cable >


62

Ref. UADU
Confidential

WiMAX Only

LTE Only

CDMA Only

CDMA + LTE

63

Confidential
Power

CDMA Only

UDA BH0 BH1 UDE EDSG Power OPTIC

GPS OPTIC(L0 L5) OPTIC(L0~L5)

LTE Only

UDA BH0 BH1 UDE0 UDE1

GPS BH2 BH1 REC EDGB

64

Confidential
Power OPTIC

WiMAX Only

UDA BH0 BH1 UDE0 UDE1 Power OPTIC

GPS BH2 BH1 REC EDGB

CDMA + LTE

UDA BH0 BH1 UDE EDSG

GPS OPTIC(L0~L5)

65

Ref. Single Solution Cabinet


Battery Circuit Breaker PDP Rectifier WiMAX TD-LTE/FDD TD LTE/FDD LTE CDMA CDMA/FDD LTE AC circuit breaker User space 12 DC Circuit Breaker

Confidential

User Space

Cabling Space 6 Conduits

Cabling Space

[BBU Single Cabinet] Note. This data could be revised while designing in detail.
66

You might also like