Professional Documents
Culture Documents
1 of 2
Blowout Preventers
http://www.blowout-preventers.com/ram-blowout-preventers.php
Request Quote
Contact Us
11
13-5/8
16-3/4
18-3/4
20-3/4
21-1/4
26-3/4
15,000
10,000
5,000
3,000
2,000
7-1/16
11
13-5/8
20-3/4
21-1/4
3,000
2,000
Working Pressure
(psi)
5,000
10,000
3,000
5,000
3,000
5,000
10,000
Length (inches)
58-1/4
79
60
79-1/8
72-5/8
89-1/4
3,000
5,000
10,000
5/11/2012 4:33 PM
2 of 2
Width (inches)
http://www.blowout-preventers.com/ram-blowout-preventers.php
21-1/2
30
21-1/2
38-9/16
40-3/4
40-3/4
43-1/16
41-1/4
40-7/8
Height (inches),
Single, Stud x Stud
15
22-7/8
11-1/8
14-1/2
14-1/2
19-1/2
23-1/2
17-1/4
17-1/4
28
23-1/8
23-1/8
Height (inches),
Double, Stud x Stud
26-3/4
36-5/8
22
29-1/2
29-3/8
33
40-7/8
34
34
46
49-1/4
44-7/16
Weight (lbs),
Single, Stud x Stud
1,385
5,550
1,170
2,870
2,116
4,150
11,100
8,400
8,800
13,200
7,448
7,285
Weight (ls),
Double, Stud x Stud
2,504
9,900
2,200
5,750
4,096
7,725
20,560
15,350
15,620
23,400
14,615
14,455
Gallons to Open
1.18
2.34
0.68
2.27
1.45
2.62
7.0
4.46
4.46
10.52
4.46
4.46
Gallons to Close
1.45
2.72
0.77
2.58
1.74
2.98
9.45
5.44
5.44
10.58
5.07
5.07
5.45:1
7.11:1
4.5:1
5.57:1
5.45:1
5.57:1
7.11:1
5.54:1
5.54:1
7.11:1
5.57:1
5.57:1
20-3/4
21-1/4
Closing Ratio
*This is only a partial listing of our ram blowout preventers. Data in this table are for reference only.
7-1/16
11
13-5/8
5,000
10,000
3,000
5,000
10,000
15,000
3,000
5,000
10,000
15,000
3,000
2,000
74
74
95.25
96.25
96.25
124
112.13
112.13
114.13
139.00
143.69
143.69
20.25
20.63
25.13
25.13
25.75
32
29.25
29.25
30.25
39.50
39.52
39.52
27.50
30.56
29.06
34.31
35.69
44.81
31.31
33.81
41.69
53.69
40.56
37.9
44.19
48.63
49.25
54.50
55.88
69.75
53.38
55.88
66.63
81.75
66.13
62.75
2,800
3,550
5,300
5,600
6,400
10,300
7,200
7,700
10,300
23,700
13,650
13,250
5,200
6,400
9,900
10,200
11,300
18,400
14,300
14,800
18,400
43,250
25,550
25,150
Locking Screw
Turns (Each End)
18
18
27
27
27
32
32
32
32
45
46
46
Gallons to Open
1.3
1.3
3.4
3.4
3.4
5.7
5.5
5.5
5.5
10.4
8.1
9.0
Gallons to Close
1.3
1.3
3.5
3.5
3.5
5.8
5.8
5.8
5.8
10.6
8.7
8.7
6.9:1
6.9:1
7.3:1
7.3:1
7.3:1
9.8:1
7.0:1
7.0:1
7.0:1
10.6:1
7.0:1
7.0:1
Length (inches)
Width (inches)
Height (inches),
Single,
Flange x Flange
Height (inches),
Double,
Flange x Flange
Weight (lbs),
Single,
Flange x Flange
Weight (lbs),
Double,
Flange x Flange
Closing Ratio
*This is only a partial listing of our ram blowout preventers. Data in this table are for reference only.
Blowout Preventer
5/11/2012 4:33 PM