Plumbing Layout

SUBMITTED TO: ENGR. MARJUN B. MACASILHIG

11/15/2011 SUBMITTED BY: LLAVORES, MA. SOCORRO ANGELA E. MADERA, JOMELYN MORALES, PAULA COLINNE OGNITA, OLIVER OLA, MARVIN

COS/CLA BUILDING FIRST FLOOR LAVATORY WATER CLOSET FLOOR DRAIN SLOP SINK URINAL FUV 3 6 2 3 6 QTY 7 13 7 1 6

21 78 14 3 36 =152 SIZE OF PIPE: HORIZONTAL= 4 inches VERTICAL= 4 inches

SECOND FLOOR LAVATORY WATER CLOSET FLOOR DRAIN SLOP SINK PEDESTAL URINAL

FUV 3 6 2 3 6 6

QTY 14 8 5 1 1 1

42 48 10 3 6 6 =115 OF SIZE OF PIPE HORIZONTAL=4 inches VERTICAL= 4 inches

THIRD FLOOR LAVATORY WATER CLOSET FLOOR DRAIN

FUV 3 6 2

QTY 10 7 2

30 42 4 =76 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 4 inches

FOURTH FLOOR LAVATORY WATER CLOSET FLOOR DRAIN

FUV 3 6 2

QTY 4 4 11

12 24 22 =76 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 4 inches

IRTC FIRST FLOOR LAVATORY WATER CLOSET FLOOR DRAIN URINAL FUV 3 6 2 6 QTY 9 4 2 12

27 24 4 72 =127 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 4 inches

SECOND FLOOR LAVATORY WATER CLOSET FLOOR DRAIN URINAL

FUV 3 6 2 6

QTY 9 4 2 12

27 24 4 72 =127 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 4 inches

THIRD FLOOR LAVATORY WATER CLOSET FLOOR DRAIN URINAL

FUV 3 6 2 6

QTY 11 6 3 12

33 36 6 72 =147 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 4 inches

SECOND FLOOR LAVATORY WATER CLOSET FLOOR DRAIN URINAL

FUV 3 6 2 6

QTY 9 4 2 12

27 24 4 72 =127 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 4 inches

CAFA/CIE FIRST FLOOR WATER CLOSET LAVATORY URINAL FLOOR DRAIN FUV 6 3 6 2 QTY 10 9 3 12

60 27 18 24 =129 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 4 inches

SECOND FLOOR WATER CLOSET LAVATORY URINAL FLOOR DRAIN

FUV 6 3 6 2

QTY 9 14 3 11

54 42 18 22 =136 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 4 inches

THIRD FLOOR WATER CLOSET LAVATORY URINAL FLOOR DRAIN

FUV 6 3 6 2

QTY 8 8 3 9

48 24 18 18 =112 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 4 inches

FOURTH FLOOR WATER CLOSET LAVATORY URINAL FLOOR DRAIN

FUV 6 3 6 2

QTY 16 15 3 18

96 45 18 36 =195 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 4 inches

GAPT FIRST FLOOR LAVATORY FLOOR DRAIN WATER CLOSET SLOP SINK URINAL FUV 3 2 6 3 6 QTY 4 2 8 1 2

12 4 48 3 12 =79 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 4 inches

ADMINISTRATION FIRST FLOOR LAVATORY FLOOR DRAIN WATER CLOSET URINAL FUV 3 2 6 6 QTY 6 2 4 6

18 4 24 36 =82 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 4 inches

CIT FIRST FLOOR LAVATORY FLOOR DRAIN WATER CLOSET SLOP SINK URINAL FUV 3 2 6 3 6 QTY 7 2 10 1 5

21 4 60 3 30 =118 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 4 inches

SECOND FLOOR LAVATORY FLOOR DRAIN WATER CLOSET SLOP SINK URINAL

FUV 3 2 6 3 6

QTY 10 2 10 1 5 OF SIZE OF PIPE

30 4 60 3 30 =127

HORIZONTAL= 4 inches VERTICAL= 4 inches THIRD FLOOR LAVATORY FLOOR DRAIN WATER CLOSET SLOP SINK URINAL FUV 3 2 6 3 6 QTY 10 3 10 1 5 30 6 60 3 30 =129 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 4 inches ESEP FIRST FLOOR LAVATORY FLOOR DRAIN WATER CLOSET FUV 3 2 6 QTY 6 3 3

18 6 18 =42 OF SIZE OF PIPE HORIZONTAL= 4 inches VERTICAL= 3 inches

COURT FUV 3 2 6 6 QTY 2 4 2 1

LAVATORY FLOOR DRAIN WATER CLOSET URINAL

6 8 12 6 =32 SIZE OF PIPE HORIZONTAL= 3 inches VERTICAL= 2 inches