Professional Documents
Culture Documents
50.0
in
80.0
in
70.0
in
2.8
4 D/T Ratio
Agitator rpm
0.5
N
110
=
=
1100
100
0.6
Reynolds Number
Re
8132
Np
1.37
1.61
Pumping Number
Nq
0.6
Equivalent Diameter
Teq
5.00
9.9
13.6
Velocity
0.729
Fluid Properties
Density
Viscosity
Calculation
1) Reynolds Number
2)Power Requirement
Power Number
Power Required
(Assuming 80% Loading)
3) Mixing Intensity
4) Agitator required
No of Agitators Required
Z/T
=
=
2
1.40
in
in
in
m3
de Turbine
rpm
kg/m3
cp
Use 5.5 for Rushton six blade turbine & 3.2 for
concave 180 degree turbine
ft3/sec
ft2
ft/sec
Click here
Click Here
0.25
0.3
0.4
0.5
Chemineer HD3
Wide Hydrofoil
Pitched Blade Turbine
Rushton 6 Blade Turbine
180 Degree Concave
Wide Hydrofoil
Back to data
sheet
Power Number
Narrow Hydrofoil
0.8
Power No
Reynolds No
Power Number
0.7
100
200
300
0.6
500
800
0.5
1200
3000
10000
0.4
D/T=0.25
D/T=0.3
D/T=0.4
D/T=0.5
0.73
0.53
0.47
0.41
0.38
0.36
0.33
0.33
0.71
0.52
0.45
0.39
0.37
0.34
0.32
0.32
0.69
0.49
0.42
0.37
0.34
0.32
0.3
0.29
0.68
0.46
0.4
0.35
0.32
0.3
0.28
0.27
0.3
0.2
0.1
0
100
1100
2100
3100
Column C
4100
Column D
5100
6100
Reynolds
Column
E Number
Column F
7100
81
6100
ds Number
Column F
7100
8100
9100
10100
11100
Wide Hydrofoil
Power No
D/T=0.25
D/T=0.3
D/T=0.4
D/T=0.5
100
200 2
300
500
800
1.5
1200
3000
10000
2.28
1.78
1.56
1.3
1.14
1.09
1.06
1.06
2.24
1.75
1.53
1.29
1.12
1.08
1.05
1.05
2.15
1.69
1.48
1.24
1.09
1.05
1
1
2.11
1.65
1.45
1.23
1.08
1.03
0.98
0.98
2100
3100
Power Number
2.5
Reynolds
No
0.5
0
100
1100
Column C
4100
Column D
5100
6100
Column ENumber
Column F
Reynolds
7100
5100
6100
olumn
Column F
ynoldsENumber
7100
8100
9100
10100
11100
Pitched Blade
2.5
Power No
Power Number
Reynolds
2
No
100
200
1.5
300
500
800
1
1200
3000
10000
0.5
0
100
D/T=0.25
D/T=0.3
D/T=0.4
D/T=0.5
2.14
1.75
1.6
1.46
1.38
1.37
1.37
1.37
2.14
1.75
1.6
1.46
1.38
1.37
1.37
1.37
2.14
1.75
1.6
1.46
1.38
1.37
1.37
1.37
2.14
1.72
1.6
1.46
1.38
1.37
1.37
1.37
1100
2100
3100
4100
5100
6100
Reynolds Number
7100
Column
Column
Column
Column
6100
ds Number
7100
8100
9100
10100
C
D
E
F
11100
Rushton 6 Blade
Reynolds
No
100
200
300
500
800
1200
3000
10000
D/T=0.25
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
Power No
D/T=0.3
D/T=0.4
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
D/T=0.5
5.5
5.4
5.5
5.5
5.5
5.5
5.5
5.5
Power No
D/T=0.3
D/T=0.4
3.6
3.6
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
3.2
D/T=0.5
3.6
3.15
3.2
3.2
3.2
3.2
3.2
3.2
D/T=0.25
3.6
3.2
3.2
3.2
3.2
3.2
3.2
3.2
Chemineer HE3
Pumping Number
0.6
Reynolds
No
D/T=0.25
100
0.33
0.5
200
0.34
300
0.36
500 0.4
0.38
800
0.43
1200
0.45
3000 0.3
0.51
10000
0.57
Power No
D/T=0.3
D/T=0.4
0.31
0.3
0.33
0.32
0.35
0.34
0.36
0.36
0.42
0.41
0.44
0.43
0.47
0.45
0.55
0.53
D/T=0.5
0.3
0.32
0.34
0.35
0.39
0.41
0.44
0.51
0.2
0.1
0
100
1100
2100
3100
4100
5100
6100
Reynolds Number
71
Column
Column
Column
Column
6100
olds Number
7100
8100
9100
10100
C
D
E
F
11100
Wide Hydrofoil
Pumping Number
Reynolds
0.9
No
100
0.8
200
300
0.7
500
800
0.61200
3000
0.5
10000
D/T=0.25
0.44
0.54
0.58
0.64
0.67
0.71
0.77
0.8
D/T=0.5
0.35
0.4
0.43
0.46
0.48
0.5
0.55
0.56
Power No
D/T=0.3
D/T=0.4
0.42
0.37
0.5
0.45
0.54
0.48
0.61
0.54
0.65
0.57
0.67
0.6
2100
3100
0.75
0.66
0.8
0.68
D/T=0.5
0.36
0.41
0.44
0.47
0.5
0.52
4100
0.57
0.6
Pitched
Blade
0.4
Reynolds
0.3
No
100
0.2
200
300
0.1
500
800
01200
100
3000
10000
D/T=0.25
0.45
0.55
0.6
0.66
0.7
0.74
1100
0.82
0.88
5100
6100
Reynolds Number
7100
Column C
Column D
Column E
Column F
6100
Number
7100
8100
9100
10100
11100
Pitched Blade
1
Pumping Number
Reynolds
No 0.9 D/T=0.25
100
0.45
0.8
200
0.55
300 0.7
0.6
500
0.66
0.6
800
0.7
12000.5
0.74
3000
0.82
0.4
10000
0.88
Power No
D/T=0.3
D/T=0.4
0.42
0.37
0.5
0.45
0.54
0.48
0.61
0.54
0.65
0.57
0.67
0.6
0.75
0.66
0.8
0.68
D/T=0.5
0.36
0.41
0.44
0.47
0.5
0.52
0.57
0.6
0.3
0.2
0.1
0
100
1100
2100
3100
4100
5100
6100
Reynolds Number
00
Column
Column
Column
Column
6100
nolds Number
7100
8100
9100
10100
C
D
E
F
11100
Rushton 6 blade
Reynolds
No
100
200
300
500
800
1200
3000
10000
D/T=0.25
0.7
0.72
0.72
0.72
0.72
0.72
0.72
0.72
Power No
D/T=0.3
D/T=0.4
0.7
0.7
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
0.72
D/T=0.5
0.7
0.72
0.72
0.72
0.72
0.72
0.72
0.72
D/T=0.3
0.68
0.7
0.7
0.7
0.7
0.7
0.7
0.7
D/T=0.5
0.68
0.7
0.7
0.7
0.7
0.7
0.7
0.7
Power No
D/T=0.25
0.68
0.7
0.7
0.7
0.7
0.7
0.7
0.7
D/T=0.4
0.68
0.7
0.7
0.7
0.7
0.7
0.7
0.7