The basic type of air conditioning are Non Ductable system Ductable system
AIR CONDITIONING
NON-DUCTABLE PRODUCTS
DUCTABLE SYSTEM
CENTRAL PLANTS
FLOOR MOUNTED
WALL MOUNTED
CEILING MOUNTED
AIR COOLED
CASSETTE TYPE RECIPROCATING UNITS, AIR AND WATER COOLED SCREW TYPE UNIT, WATER COOLED
DIRECT FIRED
Advantages Outdoor unit can be mounted on roof or the ledge some distance away from the room to be air conditioned . They are preferred for their low noise levels. Disadvantages Split air conditioners are more expensive than the window mounted type. Types Of Split Air Conditioners Indoor Unit The out door units are always similar The indoor units are available in different types to suit the needs of air conditioner space The different types of indoor units are floor mounted High wall mounted Ceiling mounted
Floor Mounted
it is kept on the floor against the wall of the space to be air conditioned Here air throw is from the top, the space above the indoor unit must be free from obstructions
Mounting safety and serviceability In wall mounted units ,the wall to which out door unit support frame work is grouted , is structurally sound and capable of supporting its load and this applies to any other structure on which ODU is mounted This frame work should be properly designed with a catwalk to permit serviceability along with safety railing Coastal installation Following taken into consideration The condenser fan outlet is not facing see wind. ODU are not located near ground level , close to beach. Care is taken to give supporting frame work ,a good quality anticorrosive paint treatment The isolator switch and electrical components are properly protected from moisture.
This type is ideal for living rooms or office rooms where adequate floor space is available.
Ceiling Mounted
1. These are designed to be suspended from the main ceiling They are available in three models. Exposed
2. Hidden 3. Cassette Exposed They are fixed directly to the ceiling and are visible. Units are similar to floor mounted units
These are easy to install Are preferred in commercial areas or offices that do not have a false ceiling . Hide /away These units are mounted on the ceilings but designed for the hidden . They are concealed by a paneled box or false ceiling. These are suitable for commercial areas where the interior design required concealed air conditioning equipment . It is used in places like restaurant and office. Cassette type These are mounted above the false ceiling with out let grill flushed with bottom of false ceiling. A small motorized pump is employed to the drained out the condensate.
Advantages
They required a small plant room They are serviced friendly bcoz of easy accessibility They can handle long ducts with used of more powerful fans Large tonnage can be handle. Interiors are clean and undisturbed as machines are placed in separate plat room
CENTRAL PLANTS
Central plants are large air conditioning plants assembled at the site. These are used for big buildings,such as hotels , theaters , hospitals , large office complexes and factories They are designed for accurate control of all parameters of comfort A central plant is housed in the central location These plant room could be in the basement or adjutants to the building They consist of equipments such as one or more compressors, condensers ,air handling units, water chillers and cooling tower. They can use direct expansion (DX)or chilled water
In DX plants the place where this heat exchange takes place is called as air handing unit (AHU) This system typically uses ducting passing through structure to the various parts of the building to be conditioned.
RECIPROCATIVE TYPE:
It employs a crane shaft to drive reciprocating piston to compress the refrigerant Used where application ranging from less than a ton to 120 tons .
Centrifugal Compressor
This employs 1 or more rapidly spinning disks to force the refrigerant gas from it centre to it extremity there by increasing it volume into its increase pressure. Used in application from 150TR to several thousand tons
These can be classified as( depending on compressors used) Reciprocating chillers Screw chillers Centrifugal chillers Where absorptions system is used chillers are called absorption chillers .
Centrifugal chiller
Absorption chiller
Vapour absorption machine This employs cooling cycle know as absorption refrigeration This is used for large application with some form of heat source is economically available It consist of evaporator and absorber Inside absorber there is salt solution , lithium bromide , has strong affinity to water In low pressure evaporator chamber has water and a mist of water vapour The salt solution in absorber chamber absorbs water vapour from low pressure evaporator chamber this maintain the low pressure in evaporator chamber and causes water temperature to drop The solution formed by mixing of water and salt is heated so that salt solution is regenerated The solution is pump through higher pressure section where heat is used to separate the refrigerant (water )from absorbent salt (lithium bromide Salt then releases water evapour at high temperature Vapour is condensed in condenser to water using cool water from cooling tower and return to evaporator to begin the cycle again .
Air handling unit it is a centrifugal type fan that pumps the air this fan is usually located in the air handler/water coil cabinet its purpose is to create a pressure differential so that the air from the conditioned space is drawn back to the unit. The air passed through a filter first to remove the dust and then over the the coils or chilled water coil where the heat is rejected this cooled air is drawn back into the suction fan then back feed into the conditioned space which is to be cooled. A damper arrangement in the suction side of AHU is kept alittle open to draw in the fresh air . AHU is sheet steel cabinet housing cooling coil and blower fan. Motor being mounted on outside the cabinet , drives the blower by a pulley belt arrangement. Depending on appications AHUs varies in sizes.
Fan coil unit it is a sheet metal cabinet that houses a chilled water coil constructed out of copper tube and aluminum fins. , boiler with motor and an air filter. It is used where multiple areas are to be cooled . The water is chilled centrally and pumped to various parts of the building through insulated pipes the chilled water enter the FCU , where heat exchange take place between the room air and the chilled water in the coil. Air passed over the coils using a three speed blower motor, mounted in the FCU The air speed can be controlled by choosing the bower motor speed from a selector switched in the conditioned space Thermostat is mounted in the air conditioned space that controls a solenoid valve that closes when desire temperature is reached and shuts of flow of chilled water in FCU water coil and when temperature rises the thermostat activates the solenoid valve to open and allowing chilled water flow in the coil
Freshening Air
Installation practice for air coil units The indoor units of any split air conditioners are connected to out door unit through refrigerant piping which is imported copper pipe Soft drawn copper tubing is used for single phase non ducted split air conditioners and hard drawn , l grad copper tubing is used for three phase ducted splits or package units