Drawing Set for

The Forsyth County Water Treatment Plant Expansion


12.0 MGD - ZEEWEED 1000

Project Number: 500408

12

11

10

VALVE & GATE SYMBOLS


H

EQUIPMENT SYMBOLS
P&ID LINE TYPES

LINE SYMBOLS & MISC.


INSTRUMENTATION LINES I/P CONVERTER (ELECTRIC ANALOG TO PNEUMATIC SIGNAL CONVERTER)
R T

LINE DESIGNATION
(SIZE,SCHEDULE,MATERIAL)

H
RESIN TRAP
EX. SIZE (x"), SCHEDULE, MATERIAL NORMALLY CLOSED NORMALLY OPEN I P

MAIN PROCESS LINE

CONICAL OR TEMPORARY STRAINER

4", SCH.80, PVC

DIAPHRAGM

COMPRESSOR PISTON

BLOWER (GENERIC)

PUMP (GENERIC)

DIAPHRAGM PUMP

PROCESS LINE MECHANICAL LINK EQUIPMENT/LINE SUPPLIED BY OTHERS Y STRAINER ULTRASONIC/ELECTROMAGNETIC


MOST COMMON MATERIALS SCH.80, PVC SCH.80, CPVC SCH.10, 316L SS SCH.40, C.S. P.E. TUBING SS TUBING NYLON TUBING

BUTTERFLY

BALL
COMPRESSOR ROTARY SCREW LOBE BLOWER CENTRIFUGAL PUMP METERING PUMP

SKID BOUNDARY

INSTRUMENT CONNECTION ELECTRIC SIGNAL (ANALOG OR DIGITAL)

STEAM TRAP

SCH.40, 316L SS SCH.10, 304L SS

FUTURE EQUIPMENT

BALL (MANUAL)

CYLINDRICAL STRAINER

SCH.40, 304L SS

GATE OR OTHER IN-LINE TYPE NOT OTHERWISE IDENTIFIED

REVISED ITEM

PNEUMATIC SIGNAL FLOOR DRAIN

CLIENT INTERFACE SIGNALS


OTHER COMBINATIONS OF ANALOG/DIGITAL & DATA HIGHWAY COMMUNICATION MUST ALSO BE SHOWN AS REQUIRED

TURBINE

CENTRIFUGAL BLOWER

POSITIVE DISPLACEMENT PUMP

VACUUM PUMP (WET OR DRY) OPTIONAL ITEM

SOFTWARE LINK THERMOWELL CAPILLARY TUBING


SIGNAL

GLOBE

CALCULATED VALUE

PI

PLUG OR ANGLE SEAT

AIR DRYER

REGENERATIVE BLOWER

TURBINE PUMP

AXIAL FLOW PUMP

PIG TAIL LOCAL PANEL TERMINATION TAG FLEXIBLE HOSE


SIGNAL FROM

NEEDLE
ELECTRIC TRACE & INSULATION PIPING SPOOL TAG NON-FLEX CONNECTION

PINCH

DESICCANT DRYER

CAN PUMP

SUBMERSIBLE PUMP

TO

F
REVISION TRIANGLE VICTAULIC CONNECTION

K KNIFE GATE

CONTINUATION SYMBOLS CAMLOCK CONNECTION P&ID TIE - INS

COMMON ABBREVIATIONS
IAS SP MCC INSTRUMENT AIR SUPPLY SET POINT MOTOR CONTROL CENTER MAGNETIC HAND-OFF AUTO LOCAL-OFF REMOTE

FLANGED CONNECTION
EX. PERMEATE

SLIDING GATE

XXXXXX-D-XXX

BLIND FLANGE CAPPED CONNECTION

MAG HOA LOR

TO STORAGE TANK TK-XX XX USGPM

E-STOP EMERGENCY STOP

S
SOLENOID VALVE
GRANULAR ACTIVATED WATER SOFTENER PORTABLE EXCHANGE TANK CARBON FILTER (GAC) OR MULTI MEDIA FILTER (MMF) UV STERILIZER MEMBRANE MODULES & HOUSING (IF REQD)

DI

DIGITAL INPUT DIGITAL OUTPUT ANALOG INPUT ANALOG OUTPUT FOUNDATION FIELD BUS DEVICE NET

U C I N Y B L N T U E T N E E A G N R L I S R M N A D F N T O S M O S
HH LOCATED ON SKID CONTROL PANEL FIELD MOUNTED AUXILIARY LOCATION NORMALLY ACCESSIBLE TO OPERATOR

DO AI AO

E
SAMPLE VALVE

LA

H L LL

PLC ALARM FUNCTION WITH MULTIPLE TRIGGER POINTS SEE INSTRUMENT LETTERS

SUMMING

FF

D.NET

CHECK
HEAT EXCHANGER HEATER HEATING/ COOLING COIL
DISCRETE INSTRUMENTS

/n S

AVERAGING

INSTRUMENTS SHARING COMMON HOUSING LOW SELECTING

BACKFLOW PREVENTER

HUMAN MACHINE INTERFACE HMI

PILOT LIGHT HIGH SELECTING

INJECTION QUILL POSITIVEDISPLACEMENTTYPE FLOW TOTALIZING INDICATOR FLUME ROTAMETER (VARIABLE AREA FLOWMETERS)

D
THREE WAY

PADDLEWHEEL FLOWMETER

COMPUTER/DCS FUNCTION

UNDEFINED INTERLOCK LOGIC


f(x)

D
UNSPECIFIED FUNCTION

FOUR WAY

VENTURI FLOWMETER

ORIFICE PLATE IN QUICK-CHANGE FITTING

CALIBRATION COLUMN

ROTAMETER WITH BUILT-IN HAND CONTROL VALVE

PROGRAMMABLE LOGIC CONTROL

PLC-X

SYSTEMS WITH MULTIPLE PLCS

RUPTURE DISC (PRESSURE)

RUPTURE DISC (VACUUM)

FLOWMETER VORTEX OR MAGNETIC (TYPE INDICATED)

ORIFICE PLATE

FLOW STRAIGHTENING DEVICE

A E C U T R Y B L A V V L E & G T A T A O S M O S
NOTE: ON LOSS OF PRIMARY POWER (PNEUMATIC, ELECTRICAL OR HYDRAULIC) XX: FC = FAIL CLOSED FO = FAIL OPEN FL = FAIL TO LAST POSITION

C
VACUUM BREAKER STATIC MIXER MUFFLER

IF NOT SPECIFIED ASSUME FC.

C
TRAVEL STOP

F
VENT AND FILTER

FIXED SCREEN
DIFFUSER GRID

PNEUMATIC DIAPHRAGM

AUTOMATIC AIR VENT DIAPHRAGM SEAL

DOUBLE ACTING PNEUMATIC CYLINDER (INST.AIR LINES NOT ALWAYS SHOWN)

VALVE POSITIONER

PRESSURE REGULATOR

PULSATION DAMPENER

EDUCTOR/ EJECTOR

MIXER

SILENCER OR FILTER

CARTRIDGE FILTER

SPRING CLOSE PNEUMATIC CYLINDER (INST.AIR LINES NOT ALWAYS SHOWN)

HAND OVERRIDE

B
BACK PRESSURE REGULATOR
MMMMM-

SPRING OPEN PNEUMATIC CYLINDER (INST.AIR LINES NOT ALWAYS SHOWN)

ACTUATOR WITH TRAVEL STOP

SOLENOID

0
REV.

07/09/13
DATE

ISSUED FOR APPROVAL


DESCRIPTION ZONE

I.B.
DSGN

M.D.
APPD

PRESSURE RELIEF/ MULTI FUNCTION VALVE


M ELECTRIC MOTOR (DIGITAL- OPEN/CLOSED)

APPROVAL

DATE
(Y/M/D)

M-

FLOAT CONTROLLED

DRWN:

A.P.L. K.S. N.K. M.D.

07/04/20 07/04/20 07/09/12 07/09/12


CUSTOMER:

DSGN:

WPR-

MUD
PERFORATED TRAVELLING BAND SCREEN

M BASKET STRAINER (MOTOR OPTIONAL)

ELECTRIC MOTOR (ANALOG - CONTROL)

CHKD:

THE FORSYTH COUNTY - 12.0 MGD WTP

WASHPACTOR

APPD:

TITLE:

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

GRIT WASHER/ CLASSIFIER

ISA SYMBOLOGY COVER SHEET


A
SIZE: DRAWING NO. REV.

CADD FILE:

500408L1 1.DGN
SCALE:

1:1

500408-L-001
2

SHEET 1 OF 2

0
1

(24x36) D

12

11

10

12

11

10

ISA TEXT ABBREVIATIONS


MEASURED OR INDICATING VARIABLE READOUT OR PASSIVE FUNCTION

MECHANICAL OR INSTRUMENT DEVICE TAG IDENTIFICATION PREFIX


AV AIR VENT AIR COMPRESSOR ANALYSIS ELEMENT WITH ANALYSIS INDICATING TRANSMITTER ANALYSIS ELEMENT WITH ANALYSIS TRANSMITTER BLOWER BACK PRESSURE VALVE CHECK VALVE/INJECTION QUILL AIR DRIER FILTER FLOW CONTROL VALVE FLOW ELEMENT WITH FLOW INDICATING TRANSMITTER FLOW ELEMENT WITH FLOW TRANSMITTER FLOW SIGHT GLASS FLOW INDICATOR ORIFICE PLATE AUTOMATIC VALVE FLOW STRAIGHTENING DEVICE GRIT WASHER/CLASSIFIER HEATER HEATING COIL HAND CONTROL VALVE HEAT EXCHANGER HAND VALVE LEVEL CONTROL VALVE LEVEL ELEMENT WITH LEVEL INDICATING TRANSMITTER LEVEL ELEMENT WITH LEVEL TRANSMITTER LEVEL SIGHT GLASS LEVEL INDICATOR LEVEL SWITCH MULTI FUNCTION VALVE (COMBINATION RELIEF & BACKPRESSURE VALVE FOR METERING PUMPS) MIXER STATIC MIXER PUMP PULSATION DAMPENER PRESSURE ELEMENT WITH PRESSURE INDICATING TRANSMITTER PRESSURE ELEMENT WITH PRESSURE TRANSMITTER PRESSURE INDICATOR PRESSURE REGULATING VALVE PRESSURE SWITCH RUPTURE DISC PRESSURE RELIEF VALVE RESIN TRAP SCREEN SIGHT GLASS STRAINER SAMPLE VALVE TEMPERATURE CONTROL VALVE TEMPERATURE ELEMENT WITH TEMPERATURE INDICATING TRANSMITTER TEMPERATURE ELEMENT WITH TEMPERATURE TRANSMITTER TEMPERATURE INDICATOR TANK TEMPERATURE SWITCH TURBINE
0 07/09/13
DATE

MODIFIER

OUTPUT FUNCTION

MODIFIER AC

A B C D

ANALYSIS BURNER, COMBUSTION USERS CHOICE USERS CHOICE DIFFERENTIAL

ALARM USERS CHOICE USERS CHOICE CONTROL USERS CHOICE

AE/AIT AE/AT B BPV

VOLTAGE

SENSOR (PRIMARY ELEMENT)

CV DR

F G H I J K L

FLOW RATE USERS CHOICE HAND CURRENT (ELECTRICAL) POWER TIME, TIME SCHEDULE LEVEL USERS CHOICE LOG REMOVAL USERS CHOICE

RATIO (FRACTION) F GLASS, VIEWING DEVICE FCV HIGH FE/FIT INDICATE FE/FT SCAN FG TIME RATE OF CHANGE LIGHT MOMENTARY USERS CHOICE ORIFICE, RESTRICTION GWC POINT (TEST) CONNECTION USERS CHOICE CONTROL STATION FI LOW FO MIDDLE, INTERMEDIATE FV USERS CHOICE FX

M N O

PRESSURE, VACUUM

H HC HCV HE HV LCV LE/LIT LE/LT

Q R S T

QUANTITY RADIATION SPEED, FREQUENCY TEMPERATURE MULTIVARIABLE VIBRATION, MECHANICAL ANALYSIS

INTEGRATE, TOTALISE RECORD SAFETY SWITCH TRANSMIT MULTIFUNCTION MULTIFUNCTION VALVE, DAMPER, LOUVER MULTIFUNCTION

W X

WEIGHT, FORCE UNCLASSIFIED EVENT, STATE OR PRESENT X AXIS

WELL AVERAGE UNCLASSIFIED UNCLASSIFIED

LG LI LS* MFV DRIVER, ACTUATOR,

Y AXIS

RELAY, COMPUTE, CONVERT

POSITION, DIMENSION

Z AXIS

UNCLASSIFIED FINAL CONTROL ELEMENT

MX MXS P PD PE/PIT PE/PT PI PRV PS* PSE PSV RT SCR SG STR SV TCV TE/TIT TE/TT TI TK TS* TURB UV VB VS* WPR YY

ISSUED FOR APPROVAL


DESCRIPTION ZONE

I.B.
DSGN

M.D.
APPD

UV STERILIZER VACUUM BREAKER VIBRATION SWITCH

REV.

APPROVAL

DATE
(Y/M/D)

DRWN:

A.P.L. K.S. N.K. M.D.

07/04/20 07/04/20 07/09/12 07/09/12


CUSTOMER:

WASHPACTOR
DSGN:

SOLENOID FOR PNEUMATIC CONTROL OF AUTOMATIC VALVE


CHKD:

THE FORSYTH COUNTY - 12.0 MGD WTP

* ADD THE SUFFIX HH (HIGH HIGH), H (HIGH), L (LOW), LL (LOW LOW) AS REQUIRED FOR THESE ITEMS.

APPD:

TITLE:

ISA SYMBOLOGY COVER SHEET


A
SIZE: DRAWING NO. REV.

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

CADD FILE:

500408L1 2.DGN
SCALE:

1:1

500408-L-001
2

SHEET 2 OF 2

0
1

(24x36) D

12

11

10

12

11

10

G
SEALWEIR P-3500-1 TO 6 (7 TO 11 FUTURE) PROCESS PUMP

STR-7600 A

CLEARWELL FEED CHANNEL CLARIFIED WATER (BY OTHERS)

F
STR-7600 B

TK-3500-1 TO 6 (7 TO 11 FUTURE) MEMBRANE TANK (BY OTHERS)

TK-8800 BACKPULSE TANK

STR-7600 C STR-7600 A - SELF-CLEANING STRAINER

STR-7600 B - BASKET STRAINER STR-7600 C - SELF-CLEANING STRAINER (FUTURE)

B-8500A/B BACKWASH WASTE

TO BACKWASH RECOVERY BASINS NEUTRALIZED CHEMICAL WASTE

TO RESIDUALS HOLDING BASINS

SODIUM BISULFITE P-5300 A/B

SODIUM HYDROXIDE P-5500 A/B ELECTRIC WATER HEATER

C
P-9700A/B CIP PUMPS

TK-9700 CIP TANK

0
REV.

07/09/13
DATE

ISSUED FOR APPROVAL


DESCRIPTION ZONE

I.B.
DSGN

M.D.
APPD

APPROVAL

DATE
(Y/M/D)

SODIUM HYPOCHLORITE P-5100 A/B P-6600 A/B

CITRIC ACID P-6500 A/B

DRWN: I.B.

07/04/27 07/04/20 07/09/12 07/09/12


CUSTOMER:

DSGN: K.S.

CHKD: N.K.

THE FORSYTH COUNTY - 12.0 MGD WTP

APPD: M.D.

TITLE:

PROCESS FLOW DIAGRAM


A
SIZE: DRAWING NO. REV.

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

CADD FILE:

500408A001.DGN

SCALE:

1:1

500408-A-001
2

SHEET 1 OF 1

0
1

(24x36) D

12

11

10

12

11

10

H
3

SCREEN WASH WATER

FROM PLANT SERVICE

CLARIFIED WATER 36" CLD1 36", SCH.10, 304L SS

SCREENED CLARIFIED WATER


500408-D-001 SHT.2

FROM SEDIMENTATION TANK OR SUPERPULSATOR 12 MGD 24 MGD (FUTURE) STR-A

HV-7587 6"

FV-7637 1/2"

(SEE NOTE 5)

SCREENED CLARIFIED SAMPLE


500408-D-015

PI 7641B HV-7641B 1" 2 30"


M-7600B

PI 7640B HV-7640B 30" 1" 2

HV-7681B

STR-7600B 0.5mm 2 BASKET STRAINER RATED FLOW: 9365 GPM CLEAN PRESSURE DROP: 0.40 PSIG @ 12410 GPM STANDBY

HV-7680B

HV-7660B 2"

09/11/04 08/04/01 08/03/11 07/09/13


DATE

REVISED AS NOTED REVISED AS NOTED REVISED AS NOTED ISSUED FOR APPROVAL


DESCRIPTION ZONE

X.C.

M.D.

HIS

B
STR-C (SEE NOTE 5) YS NOTES: DO 1. ALL DOTTED LINES/EQUIPMENT BY OTHERS 2. STRAINER CONTROLLED BY LOCAL PANEL, NOT ZENON PLC. 3. INCLUDED WITH STRAINER PACKAGE

2 1 0
REV.

X.C.

M.D.

G.C.

M.D.

I.B.
DSGN

M.D.
APPD

APPROVAL

DATE
(Y/M/D)

DRWN:

I.B. K.S. N.K. M.D.

07/04/27 07/04/20 07/09/12 07/09/12


CUSTOMER:

DSGN:

TYP. SOLENOID VALVE CONTROL DETAIL

CHKD:

THE FORSYTH COUNTY - 12.0 MGD WTP

4. 900 GPM @ 40 PSIG NEEDED FOR BACK WASHING. 5. STRAINER SYSTEM SUPPLIED AND CONTROLLED BY OTHERS.

APPD:

TITLE:

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

CADD FILE:

500408D1 1.DGN
SIZE:

PIPING & INSTRUMENTATION DIAGRAM PRE-TREATMENT

SCALE:

1:1

DRAWING NO.

500408-D-001
2

SHEET 1 OF 2

REV.

3
1

D(24x36)

12

11

10

12

11

10

PERMEATE 10", SCH.10, 304 SS


500408-D-013

BY OTHERS

OVERFLOW 42", SCH.10, 304L SS

TO BACKWASH RECOVERY BASINS LA LY 7626 AI LIT 7626 LE SCREENED CLARIFIED WATER 30", SCH.10, 304L SS
500408-D-001,SHT.1

LI 7626

LL 7626

E
TK-7600 FEED CHANNEL

7626

RANGE: 0-60"

7626

HV-7626 1"

D
MULTIPLE LINES SCREENED CLARIFIED WATER 18", SCH.10, 304L SS
500408-D-003

TO MEMBRANE TANKS

2 1

08/04/01 08/03/11 07/09/13


DATE

REVISED AS NOTED REVISED AS NOTED ISSUED FOR APPROVAL


DESCRIPTION ZONE

X.C.

M.D.

G.C.

M.D.

NOTE: 1. ALL DOTTED LINES/EQUIPMENT BY OTHERS

0
REV.

I.B.
DSGN

M.D.
APPD

APPROVAL

DATE
(Y/M/D)

DRWN: A.P.L.

07/04/20 07/04/20 07/09/12 07/09/12


CUSTOMER:

DSGN: K.S.

CHKD: N.K.

THE FORSYTH COUNTY - 12.0 MGD WTP

APPD: M.D.

TITLE:

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

CADD FILE:

500408D1 2.DGN
SIZE:

PIPING & INSTRUMENTATION DIAGRAM DISTRIBUTION CHANNEL

SCALE:

1:1

DRAWING NO.

500408-D-001
2

SHEET 2 OF 2

REV.

2
1

(24x36) D

12

11

10

12

11

10

KQI ACCUSTIC HOOD 8500A

HIS 8500A

YL 8500A

FLL KQ YA YS 8500A DO SC 8500A AO HOA JS 8500A SC 8500A HS 8500A DI PI S.P.= 110 SCFM M-8500A 8540A HV-8540A 1/2" 3",SCH.10, 304L SS PSV-8582A " 3", SCH.10, 304L SS (SEE NOTE 4) MULTIPLE LINES 3", SCH.10, 304L SS
500408-D-003

SMY 8500A

HA 8500A DI FAL 8506A 8506A

8500A 8500A DI

FSL 8506A

DECREASING

AIR SCOUR

INLET FILTER AND SILENCER B-8500A

DISCHARGE SILENCER

S.P.= 11 PSIG

CV-8585A

HV-8580A

TO TK-3400

(SEE NOTE 3)

KQI ACCUSTIC HOOD 8500B

HIS 8500B

YL 8500B

E
KQ YA YS 8500B DO SC 8500B AO HOA JS 8500B SC 8500B HS 8500B PI S.P.= 110 SCFM M-8500B 8540B HV-8540B 1/2" FSL 8506B " (SEE NOTE 4) CV-8585B HV-8580B DECREASING FAL 8506B DI SMY 8500B HA 8500B DI FLL 8506B

8500B 8500B DI

D
INLET FILTER AND SILENCER

3",SCH.10, 304L SS PSV-8582B DISCHARGE SILENCER B-8500B (SEE NOTE 3) S.P.= 11 PSIG

3", SCH.10, 304L SS

B-8500A/B MEMBRANE BLOWERS 131-223 SCFM @ 5.32 TO 5.75 PSIG 10 HP 3600 RPM 480 V/ 3 PH/ 60 HZ

B
NOTE: 1. ALL DOTTED LINES/EQUIPMENT BY OTHERS.

2 1 0
REV.

08/04/01 08/03/11 07/09/13


DATE

REVISED AS NOTED REVISED AS NOTED ISSUED FOR APPROVAL


DESCRIPTION ZONE

G.V.K. G.C.

M.D. M.D.

I.B.
DSGN

M.D.
APPD

2. ZENON TRAIN 1 TAGS SHOWN.


APPROVAL

DATE
(Y/M/D)

3. INCLUDED WITH BLOWER PACKAGE.


DRWN: I.B.

07/04/27 07/04/23 07/09/12 07/09/12


CUSTOMER:

4. ESTIMATED BLOWER DISCHARGE AIR TEMPERATURE IS 150^F. PROVIDE PROTECTION ON PIPING IS NECESSARY (BY OTHERS). 5. LOW POINT DRAINS & HIGH VENT POINTS
2
DSGN: K.S.

CHKD: N.K.

THE FORSYTH COUNTY - 12.0 MGD WTP

BY OTHERS.

APPD: M.D. CADD FILE:

TITLE:

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

500408D002.DGN
SIZE:

PIPING & INSTRUMENTATION DIAGRAM P.D. BLOWERS & ASSOC. EQUIPMENT

SCALE:

1:1

DRAWING NO.

500408-D-002
2

SHEET 1 OF 1

REV.

2
1

(24x36) D

12

11

10

12

11

10

EJECTOR ASSEMBLY NOTE 3

AIR SUPPLY ASSEMBLY

AIR SUPPLY " NPS-F " ODT, PP TUBING PI (BY OTHERS)

YS 9267-1 DO INSTRUMENT AIR ",SCH.40, 304L SS

13.5 SCFM @ 80 PSIG


500408-D-012

MIT AIR 1", SCH.10, 304L SS


500408-D-012

9240-1 FV-9267-1 " F-9200-1 " HV-9290-1 "

FROM AC-9100 A/B

FROM AC-9100 A/B

HV-3466-1

FV-3467-1

FV-9268-1 1" P-9200-1 VACUUM EJECTOR (FOR PRIMING) PDIC 8823-1 PDIC 3423-1 PDL L 3423-1 PDL 8823-1 PDL 8123-1 H LL H TMP EXHAUST 1" FLEX HOSE OR PVC (BY OTHERS) PDA L LL 3423-1 H PDA 8123-1

HV-9291-1 1"

1"

1",SCH.40, 304L SS

PDA

PDC

PDC

8823-1 8823-1 3423-1

PERMEATE/BACKPULSE 12", SCH.10, 304L SS 12", SCH.10, 304L SS


500408-D-005

TO P-3500/FROM BACKPULSE SYSTEM

HH LIC LI LL H L LL

3426-1 3426-1 3426-1


2

HV-3482A-1 OVERFLOW TO DISTRIBUTION 10"

HV-3482B-1 10"

HH LC LY LA H L LL

CHANNEL

3426-1 3426-1 3426-1 AI LIT 3426-1

HIS 3463-1

E
CASSETTE A-1 CASSETTE B-1

LE 3426-1 ZC 3463-1 AO RANGE: 4 TO 140 IN

I P SCREENED CLARIFIED WATER 18", SCH.10, 304L SS

IAS

HV-3426-1 1" TK-3400-1 MEMBRANE TANK 2 ZW-1000 v3 CASSETTES OF 51/60 MODULES PER TRAIN CONCRETE CONSTRUCTION

500408-D-001,SHT.2

FROM DISTRIBUTION CHANNEL

HV-3463-1

FCV-3463-1 BAFFLE PLATE (BY OTHERS)

HV-3484A-1 2" AIR SCOUR 3", SCH.10, 304L SS


500408-D-002

HV-3484B-1 2"

(SEE NOTE 4) 3", SCH.10, 304L SS FV-3473-1 CIP / DRAIN 6", SCH.80, CPVC
500408-D-010

FROM B-8500 A/B

ZC FV-9761A-1

FV-9761B-1

3463-1

AO FV-9761C-1 I 2" P IAS F.O.

RECIRCULATION RETURN/ TANK DRAIN FOR CLEAN

HIS 3463-1

BACKWASH WASTE 18", SCH.10, 304L SS

FCV-3863-1 HV-3887-1 1" HIS HIS

TO BACKWASH RECOVERY BASINS

B
DO

YS YS

2 1

08/04/01 08/03/11 07/09/13


DATE

REVISED AS NOTED REVISED AS NOTED ISSUED FOR APPROVAL


DESCRIPTION ZONE

G.V.K.

M.D.

G.C.

M.D.

NOTES: EXHAUST DO 1. ALL DOTTED LINES/EQUIPMENT


0
REV.

I.B.
DSGN

M.D.
APPD

S S
IAS FC

BY OTHERS. 2. DRAWING TYPICAL FOR TRAINS 1 TO 6. ZENON TRAIN 1 TAGS SHOWN. 3. EJECTORS TO BE LOCATED AT HIGH POINT IN PIPING

APPROVAL

DATE
(Y/M/D)

DRWN: I.B.

07/04/27 07/04/23 07/09/12 07/09/12


CUSTOMER:

DSGN: K.S.

4. A PORTION OF THE AIR HEADER NEEDS TO BE LOCATED ABOVE THE HIGHEST


CHKD: N.K.

TYP. PNEUMATIC ACTUATED VALVE CONTROL DETAIL

ANGLE SEAT VALVE CONTROL DETAIL

WATER LEVEL IN THE MEMBRANE TANK.


APPD: M.D. CADD FILE: TITLE:

THE FORSYTH COUNTY - 12.0 MGD WTP

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

500408D003.DGN
SIZE:

PIPING & INSTRUMENTATION DIAGRAM MEMBRANES & ASSOC. EQUIPEMENT

SCALE:

1:1

DRAWING NO.

500408-D-003
2

SHEET 1 OF 1

REV.

2
1

(24x36) D

12

11

10

12

11

10

10", SCH.10, 304L SS

HIS

YL

TLH FQJ 3522-1 FIC FC FC

FQJI 3522-1 FIC 3522-1 FQMI 3522-1 FQI 3522-1 H L H L FL 3522-1

3500-1 3500-1 3500-1

HH

HH PL PI YA YS SC SM HA TAH H L

3520-1 FL

3520-1 FA

HH H

3522-1 FQM 3522-1

F
PLH

H L LL

3523-1 3523-1

3500-1 3500-1 3500-1 3500-1 3500-1 3500-1 DI DO AO HOA DI HOA HS YL

LL 3520-1 FQI FJI

L 3520-1 LL FJ FFMY FQ

HH 8807-1 H L LL AI PAH 8807-1 S.P.= 11 PSIG INCREASING DI RANGE: -15 TO 15 PSIG PIT 3523-1 PE 3523-1 PI 3541-1 JC M-3500-1 PERMEATE/ 8807-1 12", SCH.10, 304L SS
500408-D-003

FQ 3520-1 3520-1 FQMI FIC 3520-1 3520AI 3520-1 3522-1 FC FY 8820-1 8820-1 8820-1 H FIT 3520-1 FE FQM 3540-1 RANGE: 0 TO 2000 GPM HV-3540-1 3520-1 8820-1 FQJ 8820-1 FA H 3522-1

PA

PY

KQI

JS

SC

3523-1 3523-1

3500-1 3500-1 3500-1 3500-1 3500-1 FV-8860-1

FQJI I TSH 3500-1 PI

FL

8820-1 8820-1 L

8820-1 L

PSH

HV-3541-1 "

3500-1 8" 10"

BACKPULSE

"

PERMEATE 10", SCH.10, 304L SS


500408-D-013

10", SCH.10, 304L SS

CV-3585-1 FROM/TO MEMBRANES FV-3561-1 HV-3586-1 1"


2

MAG HV-3587-1 P-3500-1 PROCESS PUMP 1871 GPM @ 41.2 FT 30HP, 880 RPM 480 V/ 3 PH/ 60 HZ 1"
S

FV-3560-1

TO COMMON PERMEATE HEADER

(SEE NOTE 3)

FV-3536A "

PERMEATE SAMPLE 1/2", P.E. TUBING


500408-D-015

FV-8861-1

BACKPULSE WATER 12", SCH.10, 304L SS


500408-D-007

FROM BACKPULSE TANK

HIS

B
DO

HIS YS NOTES: 1. ALL DOTTED LINES/EQUIPMENT EXHAUST BY OTHERS

2 1 0

08/04/01 08/03/11 07/09/13


DATE

REVISED AS NOTED REVISED AS NOTED ISSUED FOR APPROVAL


DESCRIPTION ZONE

G.V.K.

M.D.

G.C.

M.D.

I.B.
DSGN

M.D.
APPD

S
IAS

YS

2. DRAWING TYPICAL FOR TRAINS 1 TO 6. ZENON TRAIN 1 TAGS SHOWN. DO 3. 5 PIPE DIAMETERS UPSTREAM, 3 PIPE DIAMETERS DOWNSTREAM, STRAIGHT PIPE RUN RECOMMENDED FOR MAXIMUM ACCURACY.
REV.

APPROVAL

DATE
(Y/M/D)

DRWN: I.B.

07/04/27 07/04/23 07/09/12 07/09/12


CUSTOMER:

DSGN: K.S.

TYP. PNEUMATIC ACTUATED VALVE CONTROL DETAIL

TYP. SOLENOID VALVE CONTROL DETAIL

CHKD: N.K.

THE FORSYTH COUNTY - 12.0 MGD WTP

APPD: M.D. CADD FILE:

TITLE:

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

500408D005.DGN
SIZE:

PIPING & INSTRUMENTATION DIAGRAM PROCESS PUMP & ASSOC. EQUIPMENT

SCALE:

1:1

DRAWING NO.

500408-D-005
2

SHEET 1 OF 1

REV.

2
1

(24x36) D

12

11

10

12

11

10

G
2

G
PERMEATE 6", SCH.10, 304L SS
500408-D-013

FROM COMMON PERMEATE HEADER

HV-8871
2

FV-8870 POTABLE WATER 2"(50mm), SCH.80 PVC

FROM PLANT SERVICE WATER SOURCE


2

HV-8890

SODIUM HYPOCHLORITE FOR BIOGROWTH PREVENTION ", SCH.80, CPVC


500408-D-011,SHT.1

FROM P-51002

HV-5696 CV-5685 FV-5677

HV-5697 "

VENT C/W AIR FILTER

F
2 2

F-8800 HH H L
SCH.80,PVC

LL 8826

LI 8826

LL

HH
2

H L LL

LA 8826

LY 8826 AI RANGE: 12" TO 100"

8",

TK-8800 BACKPULSE TANK 2,000 USGAL CT - 2000 PE CONSTRUCTION CV-8898

LE 8826 HV-8826 1"

LIT 8826 BACKPULSE WATER 12", SCH.10, 304L SS


500408-D-005

(SEE NOTE 2) HV-8895 4" MULTIPLE LINES HV-8884 STR-8800 TO MEMBRANES

HIS

B
DO

YS

2 1

08/04/01 08/03/11 07/09/13


DATE

REVISED AS NOTED REVISED AS NOTED ISSUED FOR APPROVAL


DESCRIPTION ZONE

G.V.K.

M.D.

G.C.

M.D.

EXHAUST

NOTES:
0
I.B.
DSGN

M.D.
APPD

S
IAS

1. ALL DOTTED LINES/EQUIPMENT BY OTHERS 2. PIPE SPOOL FOR STRAINER MAINTENANCE/ REMOVAL AND ISOLATION VALVE ACTUATION.
DRWN: I.B.
REV.

APPROVAL

DATE
(Y/M/D)

07/04/27 07/04/23 07/09/12 07/09/12


CUSTOMER:

DSGN: K.S.

CHKD: N.K.

THE FORSYTH COUNTY - 12.0 MGD WTP

TYP. PNEUMATIC ACTUATED VALVE CONTROL DETAIL

APPD: M.D. CADD FILE:

TITLE:

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

500408D007.DGN
SIZE:

PIPING & INSTRUMENTATION DIAGRAM BACKPULSE TANK & ASSOC. EQUIPMENT

SCALE:

1:1

DRAWING NO.

500408-D-007
2

SHEET 1 OF 1

REV.

2
1

(24x36) D

12

11

10

12

11

10

M-9200A

G
(SEE NOTE 4) FROM ATM. PI 9243 PI 9241 FV-9262D 1" 3", SCH.80, CPVC 3", SCH.80, CPVC HV-9241 " HCV-9292A FROM ATMOSPHERE (TYP.) FV-9261A S

2", SCH.80, CPVC

2", SCH.80, CPVC

FV-9200A FV-9292A " (SEE NOTE 5) (TYP.) P-9200A (SEE NOTE 6) (TYP.) SEE NOTE 2 (TYP.) TO ATMOSPHERE

HV-9243 AIR/VACUUM 1", SCH.80, CPVC


500408-D-003

"

FROM AIR RELEASE VALVE

FV-9262A (SEE NOTE 3) (TYP.) MULTIPLE LINES 2" 2"

FV-9262B (SEE NOTE 3) (TYP.)

F
TK-9200 LG 92-1 LIQUID RESERVOIR 30 GAL "

LSH 9202-1

DI

LAH 9202-1 M-9200B 2", SCH.80, CPVC LLH S 9202-1 FV-9261B FV-9200B FV-9292B " P-9200B 2", SCH.80, CPVC

FV-9262C 2"

TO ATMOSPHERE

M-9200C 2", SCH.80, CPVC 2", SCH.80, CPVC

FV-9261C

FV-9200C FV-9292C " P-9200C VACUUM PUMPS

2 DUTY + 1 STANDBY 67 CFM @ 25.12" HG @ 1206 FASL 7.5 HP, 3600 RPM 480 V / 3 PH / 60 Hz

TO ATMOSPHERE

HIS HIS

YL

HIS YA YS HA

NOTES: 1. ALL DOTTED LINES/EQUIPMENT BY OTHERS 2. DISCHARGE AIR MAY BE HOT AND HUMID, PROTECT
1 0 08/04/01 07/09/13
DATE

B
DO

YS

B
REVISED AS NOTED ISSUED FOR APPROVAL
DESCRIPTION ZONE

DI EXHAUST

DO

DI YS HOA

G.V.K.

M.D.

OPERATORS APPROPRIATELY.
I.B.
DSGN

M.D.
APPD

S
IAS

KQI

JS

HS

YL DO

3. TO BE INSTALLED AS CLOSE TO LIQUID RESERVOIR AS POSSIBLE. 4. VACUUM LINES TO BE SLOPED DOWN TOWARDS TK-9200
REV.

S
M-

APPROVAL

DATE
(Y/M/D)

SUCH THAT LIQUID IS NOT ALLOWED TO COLLECT IN LINES. WHERE LOW POINTS IN PIPING CANNOT BE AVOIDED, AN AUTOMATED DRAIN MUST BE INSTALLED. DISCUSS DESIGN REQUIREMENTS WITH ZENON BEFORE INSTALLING.
DSGN: K.S. DRWN: I.B.

07/04/27 07/04/23 07/09/12 07/09/12


CUSTOMER:

5. FILTER TO BE INSTALLED IN HORIZONTAL ORIENTATION. REFER TO VACUUM PUMP VENDOR DATA.


CHKD: N.K.

THE FORSYTH COUNTY - 12.0 MGD WTP

TYP. PNEUMATIC ACTUATED VALVE CONTROL DETAIL

TYP. BLOWER CONTROL DETAIL

TYP. SOLENOID VALVE CONTROL DETAIL

6. VACUUM PUMP MUST BE MOUNTED ON A STEEL FRAME FOR ANCHOR BOLT ACCESS.

APPD: M.D. CADD FILE:

TITLE:

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

500408D009.DGN
SIZE:

PIPING & INSTRUMENTATION DIAGRAM VACUUM PUMPS & ASSOC. EQUIPMENT

SCALE:

1:1

DRAWING NO.

500408-D-009
2

SHEET 1 OF 1

REV.

1
1

(24x36) D

12

11

10

12

11

10

SODIUM HYPOCHLORITE SOLUTION FOR RECOVERY CLEANS

1", SCH.80, CPVC


500408-D-011,SHT.1

FROM P-6600

SODIUM HYPOCHLORITE SOLUTION FOR MAINTENANCE CLEANS ", SCH.80, CPVC


500408-D-011,SHT.1

FROM P-5100 HIS 9700A YL 9700A HH FI 9720 FL 9720 H L LL HV-6696


2

HV-5196 YA YS 9700A DO SC 9700A AO SMY 9700A HA 9700A DI AI HOA KQI PI 9741A M-9700A HV-9741A CIP / DRAIN 6", SCH.80, CPVC
500408-D-003

HH FY 9720 FA 9720 H L LL BPV-6694 BPV-5194


2

CITRIC ACID SOLUTION FOR CLEANS ", SCH.80, CPVC


500408-D-011,SHT.1

9700A DI

CV-6698 FIT YL PI 9740A 9720 FE 9720 HV-9740A 1/2" 6", SCH.80, CPVC CV-5198 RANGE: 0 TO 1000 GPM HV-6698 FV-5160 HV-5198
2

BPV-6594

HV-6596

FROM P-6500

JS 9700A

SC 9700A

HS 9700A

9700A

9700A

CV-6598

HV-6598

4" 6"

1/2"

CV-9785A TO/FROM TK-3400 FV-9765 (MULTIPLE LINES) HV-9781A HV-9786A P-9700A

HV-9780A HV-9787A

MAG SEE NOTE 3


2
S

NOTE 6 FV-9732 1/2" ", SCH.80, CPVC

HIS 9700B

YL 9700B HV-9734 HV-9732

HCV-9734 YA 9700B DI YS 9700B DO SC 9700B AO SMY 9700B HA 9700B AE DI RESIDUAL CHLORINE ANALYZER YL 9700B PI 9740B 9741B AY M-9700B HV-9741B 1/2" 6" 4" HV-9740B 1/2" 9734 AA 9734 RANGE: TO ppm AI HH H L LL AY 9734 AIT 9734 Cl NOTE 5 NOTE 4 AE

HCV-9732

9732 AIT 9732 AI

pH RANGE: 0 TO 14 FV-9762
2

HOA KQI JS 9700B SC 9700B HS 9700B

E
PI

9700B

E
HH AA 9732 H L LL HV-5398 CV-5398 BPV-5394 HV-5396 ", SCH.80, CPVC
500408-D-011,SHT.2

9732

SODIUM BISULPHITE FOR NEUTRALIZATION

FROM P-5300

CV-9785B HV-9781B
2

HV-9780B HV-9787B

AI 9734

AL 9734

H L LL

AI 9732

AL 9732

H L LL PANEL
2

NOTE 6

HH

HH

HV-9786B

P-9700B CIP/RECIRC./NEUTRALIZATION PUMPS 1 DUTY + 1 STANDBY

SODIUM HYDROXIDE FOR NEUTRALIZATION 1", SCH.80, CPVC


500408-D-011,SHT.2

FV-9760

306 GPM @ 22.5 FT 5 HP @ 1180 RPM 480 V / 3 PH / 60 Hz 6", SCH.80, CPVC HV-5598 CV-5598 BPV-5594 HV-5596

FROM P-5500

D
YL PERMEATE 6", SCH.10, 304L SS
500408-D-013

D
HIS 9709 HH TI 9730 TL 9730 H L LL
2 2

9709

FROM COMMON PERMEATE HEADER

FV-9771 6"

FV-9770A

HA VENT 9709 DI HOA YL HS 9709

YS 9709 DO

YA 9709 DI

FV-9745

HH
2

TY RANGE: TO ^F 9730 AI

TA 9730

H L LL

SEE NOTE 2

CV-9745

POTABLE WATER 2", SCH.10, 304L SS

JS I 9709

HH H L LL 9726 LI 9726 RANGE: HH H L LL LA 9726 LY 9726 AI TO LIT 9726

TIT 9730

TE 9730 TK-9700 CIP TANK


2

9709 YLH 9709

FROM PLANT SERVICE

HV-9790

LL

WATER SOURCE

2000 USGAL PE CONSTRUCTION CT-2000 8"

TSH 9709

HK 9709 TEMP.

IN LE 9726

HV-9726

CV-9798

HX-9700 6", SCH.80, CPVC


2

ELECTRIC HEATER 37 KW HV-9795

8", SCH.10, 304L SS NEUTRALIZED CHEMICAL WASTE

FV-9775

HIS

HV-9799

TO RESIDUALS HOLDING BASINS

HIS NOTES:

B
DO

YS

1. ALL DOTTED LINES/EQUIPMENT BY OTHERS

2 1

08/04/01 08/03/11 07/09/13


DATE

REVISED AS NOTED REVISED AS NOTED ISSUED FOR APPROVAL


DESCRIPTION ZONE

X.C.

M.D.

I.B.

M.D.

EXHAUST

YS

2. PROVIDE AIR GAP.


0
I.B.
DSGN

M.D.
APPD

S
DO IAS

3. 5 PIPE DIAMETERS UPSTREAM, 3 PIPE DIAMETERS DOWNSTREAM, STRAIGHT PIPE RUN RECOMMENDED FOR MAXIMUM ACCURACY.
REV.

APPROVAL

DATE
(Y/M/D)

4. ADD GOOSE NECK TO PREVENT DURING OF CELLS PROBE. 5. DO NOT INSTALL PROBES UNTIL COMMISSIONING
2
DRWN: I.B.

07/04/27 07/04/23 07/09/12 07/09/12


CUSTOMER:

DSGN: K.S.

BEGINS. 6. INJECTION LINES TO BE LOCATED ON UNDERSIDE OF PIPES.


APPD: M.D. CADD FILE: CHKD: N.K.

THE FORSYTH COUNTY - 12.0 MGD WTP

TYP. PNEUMATIC ACTUATED VALVE CONTROL DETAIL

TYP. SOLENOID VALVE CONTROL DETAIL

TITLE:

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

500408D010.DGN
SIZE:

PIPING & INSTRUMENTATION DIAGRAM CLEANING SYSTEM TK-97

SCALE:

1:1

DRAWING NO.

500408-D-010
2

SHEET 1 OF 1

REV.

2
1

(24x36) D

12

11

10

12

11

10

SODIUM HYPOCHLORITE " FOR MAINTENANCE CLEANS ", SCH.80, CPVC


500408-D-010

H
NOTE 4

TO P-9700 DISCHARGE

SODIUM HYPOCHLORITE
2

FOR BIOGROWTH PREVENTION


500408-D-007

TO BACKPULSE TANK TK-8800 PANEL LIMITS HV-5180A HV-5180B SODIUM HYPOCHLORITE " 1", SCH.80, CPVC FOR RECOVERY CLEANS
500408-D-010

G
HV-6680A HV-6680B

NOTE 4 PANEL LIMITS

TO P-9700 DISCHARGE

", SCH.80, CPVC

1", SCH.80, CPVC

YL 5100A

HIS 5100A

HIS 5100B

YL 5100B

YL 6600A

HIS 6600A

HIS 6600B

YL 6600B

YA 5100A DI

YS 5100A DO YY 5100A HV-5187A HV-5187B

YS 5100B DO YY 5100B

YA 5100B DI

YA 6600A DI

YS 6600A DO YY 6600A HV-6687A HV-6687B

YS 6600B DO YY 6600B

YA 6600B LI DI 5100

F
P-5100A/B SODIUM HYPOCHLORITE PUMPS FOR MAINTENANCE CLEANS 0.13 GPM @ 58 PSIG MAX. 120 V/ 1 PH/ 60 HZ

PSV-5183A

PSV-5183B

PSV-6683A

PSV-6683B

F
LY P-6600A/B SODIUM HYPOCHLORITE PUMPS FOR RECOVERY CLEANS 5100 AI LIT 5100 RANGE: TBD LE 5100 1" CHEMICAL FILL LINE

CALIBRATION
", SCH.80, CPVC 1", SCH.80, CPVC

CALIBRATION
", SCH.80, CPVC 1", SCH.80, CPVC

COLUMN FQMI-5148

COLUMN FQMI-5248

P-5100A

P-5100B

P-6600A

P-5200B

1.27 GPM @ 58 PSIG MAX. 120 V/ 1 PH/ 60 HZ

HV-5181A HV-5186A HV-5186B

HV-5181B

HV-6681A HV-6686A HV-6686B

HV-6681B
2 2

FROM CHEMICAL TRANSFER PUMPS ( BY OTHERS )

LT-5100

1"

TK-5100 SODIUM HYPOCHLORITE (SEE NOTE 2)


2

D
" ", SCH.80, CPVC

CITRIC ACID FOR RECOVERY CLEANS


500408-D-010

NOTE 4 HV-6580A ", SCH.80, CPVC HV-6580B PANEL LIMITS TO P-9700 DISCHARGE

YL 6500A

HIS 6500A

HIS 6500B

YL 6500B
2

YA 6500A DI

YS 6500A DO YY 6500A HV-6587A HV-6587B

YS 6500B DO YY 6500B

YA 6500B DI

PSV-6583A

PSV-6583B

CALIBRATION
", SCH.80, CPVC

COLUMN FQMI-6548

", SCH.80, CPVC

P-6500A/B P-6500B CITRIC ACID PUMPS FOR RECOVERY CLEANS 0.1 GPM @ 58 PSIG MAX. 120 V/ 1 PH/ 60 HZ (SEE NOTE 4)

P-6500A

HV-6581A

HV-6581B HV-6586A HV-6586B


2 1 08/04/01 08/03/11 07/09/13
DATE

HIS
2

REVISEE AS NOTED REVISEE AS NOTED ISSUED FOR APPROVAL


DESCRIPTION ZONE

G.V.K.

M.D.

G.C.

M.D.

NOTES:
0
I.B.
DSGN

M.D.
APPD

1. ALL DOTTED LINES/EQUIPMENT YS BY OTHERS 2. VENT ALL CHEMICAL TANKS APPROPRIATELY DO 3. CHEMICAL PUMP SYSTEM WIRED TO LOCAL
DRWN: I.B.
REV.

APPROVAL

DATE
(Y/M/D)

07/04/27 07/04/23 07/09/12 07/09/12


CUSTOMER:

S
2

JUNCTION BOX
DSGN: K.S.

4. TEMPORARY GAUGE CONNECTIONS FOR COMMISSSING ONLY


CHKD: N.K.

THE FORSYTH COUNTY - 12.0 MGD WTP

TYP. SOLENOID VALVE CONTROL DETAIL

TK-6500 CITRIC ACID TOTE (BY OTHERS)

APPD: M.D. CADD FILE:

TITLE:

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

500408D11 1.DGN
SIZE:

PIPING & INSTRUMENTATION DIAGRAM CLEANING CHEMICALS

(SEE NOTE 2)

SCALE:

1:1

DRAWING NO.

500408-D-011
2

SHEET 1 OF 2

REV.

2
1

(24x36) D

12

11

10

12

11

10

H
SODIUM BISULFITE " ", SCH.80, CPVC
500408-D-010

TO P-9700 DISCHARGE HV-5380A ", SCH.80, CPVC HIS YL 5300A HIS 5300A 5300B YL 5300B
2

HV-5380B

PANEL LIMITS

YS

YA 5300B DI

YA 5300A DI

YS 5300A DO PSV-5383A YY 5300A CALIBRATION


", SCH.80, CPVC

5300B HV-5387A HV-5387B DO YY 5300B

PSV-5383B

COLUMN FQMI-5348

", SCH.80, CPVC

P-5300A/B P-5300B SODIUM BISULFITE PUMPS FOR NEUTRALIZATION 0.010-0.102 GPM @ 58 PSIG MAX. 120 V/ 1 PH/ 60 HZ (SEE NOTE 4)

P-5300A

F
HV-5381A HV-5386A HV-5386B HV-5381B

E
TK-5300
2

E
SODIUM BISULFITE TOTE(BY OTHERS) (SEE NOTE 2)

SODIUM HYDROXIDE " ", SCH.80, CPVC


500408-D-010

TO P-9700 DISCHARGE HV-5580A ", SCH.80, CPVC HIS YL 5500A HIS 5500A 5500B YL 5500B
2

HV-5580B

PANEL LIMITS

D
YS YA LI 5500 6400A DI YY LY 5500 CALIBRATION
", SCH.80, CPVC

D
YA 5500B DI YY 5500B YS 5500A DO PSV-5583A PSV-5583B HV-5587A HV-5587B 5500B DO

5500A

P-5500A/B
", SCH.80, CPVC

AI P-5500A LIT 5500

COLUMN FQMI-5548

SODIUM HYDROXIDE PUMPS P-5500B FOR NEUTRALIZATION 0.005-0.235 GPM @ 58 PSIG MAX. 120 V/ 1 PH/ 60 HZ (SEE NOTE 4)

RANGE: TBD LE 5500

HV-5581A HV-5586A CHEMICAL FILL LINE 1" HV-5386B

HV-5581B

LT-5100
FROM CHEMICAL TRANSFER PUMPS (BY OTHERS)

HIS

2 1

08/04/01 08/03/11 07/09/13


DATE

REVISED AS NOTED REVISED AS NOTED ISSUED FOR APPROVAL


DESCRIPTION ZONE

G.V.K. G.C. I.B.


DSGN

M.D. M.D. M.D.


APPD

NOTES:
0

YS

TK-5500 SODIUM HYDROXIDE (SEE NOTE 2) DO

1. ALL DOTTED LINES/EQUIPMENT BY OTHERS 2. VENT ALL CHEMICAL TANKS APPROPRIATELY. 3. BACK PRESSURE VALVE WILL BE SHIPPED LOOSE
REV.

APPROVAL

DATE
(Y/M/D)

DRWN: I.B.

07/04/27 07/04/23 07/09/12 07/09/12


CUSTOMER:

FOR INSTALLATION CLOSE TO INJECTION POINT.


DSGN: K.S.

4. CHEMICAL PUMP SYSTEM WIRED TO LOCAL JUNCTION BOX.


CHKD: N.K.

THE FORSYTH COUNTY - 12.0 MGD WTP

TYP. SOLENOID VALVE CONTROL DETAIL

APPD: M.D. CADD FILE:

TITLE:

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

500408D11 2.DGN
SIZE:

PIPING & INSTRUMENTATION DIAGRAM NEUTRALIZATION CHEMICALS

SCALE:

1:1

DRAWING NO.

500408-D-011
2

SHEET 2 OF 2

REV.

2
1

(24x36) D

12

11

10

12

11

10

PLL PSV-9182A 9108

G
YL AC-9100A 9100A 9108 F-9100A M-9182A YA 9100A DI YS 9100A DI TK-9100A COMPRESSED AIR RECEIVER TANK 120USGAL LOCAL HOA (SEE NOTE 6) HV-9180A 3/4" HV-9181A HV-9182A HV-9183 HV-9184 PRV-9182 1/2" AUTO-DRAIN INTEGRAL TO DRYER (SEE NOTE 6) HS I 9100B 9100B 9100B 9100B ELECTRICAL AUTO-DRAIN 120 V/ 1 PH/ 60 HZ (SEE NOTE 5) 9140A
1" 304L S.S. TUBING 1" 304L S.S. TUBING

G
PAL

DI S.P.= 70 PSIG DECREASING

PSL 9100A

S.P.= 110 PSIG DECREASING

DPI 9141

PSL 9108

"

"

"

"

1" 304L S.S. TUBING

INSTRUMENT AIR

KQI

JS I

HS

YL

REGULATOR S.P.= 80 PSIG F-9100 PRIMARY COALESCING FILTER W/ INTEGRAL AUTO-DRAIN 1 u m

MULTIPLE LINES (1 PER TRAIN) (SEE NOTE 2)

9100A 9100A HOA KQI JS

9100A 9100A

YL

PI

DI YA 9100B YS

DI

9100B

E
YL 9100B

HV-9185 (SEE NOTE 3) PSV-9182A


1" 304L S.S. TUBING

AC-9100B

F-9100B M-9182B

PSL 9100B

S.P.= 90 PSIG DECREASING DPI

PI 9541 9542

TK-9100B COMPRESSED AIR RECEIVER TANK 120USGAL (SEE NOTE 6) HV-9180B 3/4" HV-9181B HV-9182B HV-9582 HV-9583 PRV-9586 S.P.= 10 PSIG AUTO-DRAIN INTEGRAL TO DRYER (SEE NOTE 6) DR-9182 A/B REFRIGERATED AIR DRYER MAX. 35 CFM @ 100 PSIG 1/3 HP PI 9140B 120 V / 1 PH / 60 Hz " " " "

HV-9541 1/2"

MIT AIR
500408-D-003

PSV-9564 S.P.= 11 PSIG


2

HV-9580 CV-9580

TO MEMBRANES HV-9598 MULTIPLE LINES 1/2" (1 PER TRAIN)

F-9500 SECONDARY COALESCING FILTER W/ INTEGRAL AUTO-DRAIN 0.01 u m

ACF-9500 ACTIVATED CARBON FILTER W/ INTEGRAL MANUAL DRAIN 0.01 u m

DRAIN SEE NOTE 7

ELECTRICAL AUTO-DRAIN 120 V/ 1 PH/ 60 HZ (SEE NOTE 5)

AC-9100A/B AIR COMPRESSORS 1 DUTY + 1 STANDBY 7.5 HP, 1034 RPM 22.6 ACFM @ 175 PSIG MAX. 480 V/ 3 PH/ 60HZ (SEE NOTE 4,6,8) NOTES: 1. ALL DOTTED LINES/EQUIPMENT BY OTHERS

B
2. AT LEAST 1 ISOLATION VALVE PER TRAIN (BY OTHERS). 3. HANDLE FOR BYPASS VALVE TO BE REMOVED OR VALVE LOCKED IN CLOSED POSITION.

2 1 0
REV.

08/04/01 08/03/11 07/09/13


DATE

REVISED AS NOTED REVISED AS NOTED ISSUED FOR APPROVAL


DESCRIPTION ZONE

G.V.K.

M.D.

G.C.

M.D.

I.B.
DSGN

M.D.
APPD

4. FOOD GRADE OIL TO BE USED.


APPROVAL

DATE
(Y/M/D)

5. AUTO-DRAIN PLUGS INTO LOCAL OUTLET. WALL GFCI PLUG REQUIRED BY OTHERS. 6. NOT CONTROLLED BY PLC. 7. DRAIN VALVES TO BE LOCATED AT ANY LOW POINTS IN PIPING WHERE MOISTURE MAY ACCUMULATE. EXTRA VALVES BY OTHERS.
APPD: M.D. CHKD: N.K. DRWN: I.B.

07/04/26 07/04/23 07/09/12 07/09/12


CUSTOMER:

DSGN: K.S.

THE FORSYTH COUNTY - 12.0 MGD WTP

TITLE:

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

8. LOCAL CONTROL PANEL INCLUDED WITH COMPRESSOR.

CADD FILE:

500408D012.DGN
SIZE:

PIPING & INSTRUMENTATION DIAGRAM AIR SYSTEM FOR PDT EQUIP. & VALVES

SCALE:

1:1

DRAWING NO.

500408-D-012
2

SHEET 1 OF 1

REV.

2
1

(24x36) D

12

11

10

12

11

10

TI 7530

TY 7530

AI

G
RANGE: 32 TO 120^F

TIT 7530 TE 7530 PERMEATE 10", SCH.10, 316L SS


500408-D-005 2

30", SCH.10, 316L SS

"

FROM PERMEATE PUMPS MULTIPLE LINES

VACUUM BREAKER (SEE NOTE 2)

BYOTHERS

FV-7537 1/2"

F
PERMEATE 6", SCH.10, 304L SS
500408-D-007

TO TK-8800

HH LI PERMEATE 6", SCH.10, 304L SS


500408-D-010

LL 7526

H L LL

7526

TO TK-9700 LY 7526 SEAL WEIR LA 7526

HH H L LL

E
PERMEATE 10", SCH.10, 304L SS
500408-D-001,SHT.2 2

AI RANGE: LIT 7526 LE BYOTHERS 7526 TO TBD IN

COMMON PERMEATE SAMPLE


500408-D-015

TK-7500 CLEARWELL

HIS

B
1 08/04/01 07/09/13
DATE

B
REVISED AS NOTED ISSUED FOR APPROVAL
DESCRIPTION ZONE

X.C.

M.D.

NOTE: YS 1. ALL DOTTED LINES/EQUIPMENT BY OTHERS DO 2. VACUUM BREAKER TO BE INSTALLED


REV. DSGN APPD

I.B.

M.D.

APPROVAL

DATE
(Y/M/D)

AT HIGH POINT IN PIPING.


DRWN: A.P.L.

07/04/27 07/04/23 07/09/12 07/09/12


CUSTOMER:

DSGN: K.S.

TYP. SOLENOID VALVE CONTROL DETAIL

CHKD: N.K.

THE FORSYTH COUNTY - 12.0 MGD WTP

APPD: M.D.

TITLE:

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

CADD FILE:

500408D013.DGN
SIZE:

PIPING & INSTRUMENTATION DIAGRAM PERMEATE STORAGE TANK

SCALE:

1:1

DRAWING NO.

500408-D-013
2

SHEET 1 OF 1

REV.

1
1

(24x36) D

12

11

10

12

11

10

PERMEATE SAMPLE ",P.E., TUBING


500408-D-005

(PER TRAIN)

S
(SEE NOTE 2) HH A1 3536-1 AJI 3536-1 HH H AA PART 3536-1 AE 3536-1 HCV-3536A-1 AJIT 3536-1 VENT H FV-3536A-1

PANEL

AI1 HV-3537-1 3536-1 AJI AE RANGE: 0 - 1,000 mNTU 3537-1 TURB HH H 3536-1 AL1 3536-1

F
F-3536-1

AIT 3537-1

G
(NOTE 2)

TK-3536-1 AI HH AY AA H L LL S " PARTICLE COUNTER DEGASSING CYLINDER

3537-1 3537-1

HH AI AL H 1 -3536B-1 FE 3536B-1 HCV-3536B-1 3537-1 3537-1 L LL

HV-3536C-1 1/2"

F
SCREENED CLARIFIED SAMPLE ",P.E., TUBING
500408-D-001,SHT.1

TO DRAIN PANEL

HV-7637

E
RANGE: 0 - 1,000 mNTU

AE 7637 TURB

AIT 7637 AI HH AY 7637 AA 7637 H L LL TO DRAIN HH AI AL 7637 H L LL


2

7637

COMMON PERMEATE SAMPLE ",P.E., TUBING


500408-D-013

PANEL

HV-7537

AE RANGE: 0 - 1,000 mNTU 7537 TURB

AIT 7537 AI HH AY 7537 HIS AA 7537 H L LL TO DRAIN HH AI 7537 YS


2
REV. DATE DESCRIPTION ZONE DSGN APPD

B
AL 7537 H L LL
0 1

B
REVISED AS NOTED ISSUED FOR APPROVAL
G.V.K. M.D.

08/04/01 07/09/13

I.B.

M.D.

DO

NOTES: 1. ALL DOTTED LINES/EQUIPMENT BY OTHERS 2. DRAWING TYPICAL FOR TRAINS 1 TO 6.

APPROVAL

DATE
(Y/M/D)

DRWN: I.B.

07/04/27 07/04/23 07/09/12 07/09/12


CUSTOMER:

DSGN: K.S.

CHKD: N.K.

THE FORSYTH COUNTY - 12.0 MGD WTP

TYP. SOLENOID VALVE CONTROL DETAIL

APPD: M.D. CADD FILE:

TITLE:

A
THIS DOCUMENT EMBODIES DESIGNS AND INFORMATION PROPRIETARY TO GE ZENON ULC. IT IS TO BE USED ONLY FOR THE PURPOSE AND BY THE ENTITY FOR WHICH IT WAS ORIGINALLY SUPPLIED. THE DOCUMENT MAY NOT BE DUPLICATED, DISCLOSED TO ANY OTHER PERSON OR ENTITY, OR USED FOR MANUFACTURE OF THE ITEM IN PART OR IN WHOLE WITHOUT THE PRIOR WRITTEN PERMISSION OF GE ZENON ULC.

500408D015.DGN
SIZE:

PIPING & INSTRUMENTATION DIAGRAM PARTICLE COUNTER & TURBIDIMETER

SCALE:

1:1

DRAWING NO.

500408-D-015
2

SHEET 1 OF 1

REV.

1
1

(24x36) D

12

11

10