Dünya Denizcilik ve Ticaret A.Ş.

AYLIK YAPILACAKTIR

ODME TEST PROCEDURE

I- ALARM TEST:

A- ODME CIHAZINI AUTO POZISYONUNDA DEVREYE AL


OPERATE THE ODME IN AUTO POSITION
B- MANUAL OLARAK FLOW RATE’İ 500 m3/h OLARAK GİR
ADJUST FLOW RATE 500 m3/H BY MANUALLY
C-GEMİ SURATINI MANUAL OLARAK 10 KNT GİR
SET SHIPS SPEED 10 KNT BY MANUALLY
D- PPM MİKTARINI MANUAL OLARAK 620ppm GİR
ENTER PPM VALUE AS 620 ppm
E- PPM X FLOW RATE
--------------------------- FORMÜLÜNDEN MİL BAŞINA YAĞ MİKTARI 30 LT’Yİ
SPEED X 1000 GEÇECEĞİNDEN (31 LT ÇIKAR ) SİSTEM ALARM VERİCEK
TİR.
ACCORDING TO FORMULA OIL QUANTITY PER MILE WILL EXCEED 30 LT
AND ALARM WILL BE ON

II. FONKSİYON TESTİ:

A-ODME CİHAZINI AUTO POZİSYONUNDA DEVREYE AL


OPERATE THE ODME IN AUTO POSITION
B-MANUAL OLARAK FLOW RATE’İ 500 m3/h OLARAK GİR
ADJUST FLOW RATE 500 m3/H BY MANUALLY
C-GEMİ SURATİNİ MANUAL OLARAK 10 KNT GİR
SET SHIPS SPEED 10 KNT BY MANUALLY
D-PPM MİKTARINI 580 ppm GİR
ENTER PPM VALUE AS 580 ppm
E- PPM X FLOW RATE
------------------------------ FORMÜLÜNDEN MİL BAŞINA YAĞ MİKTARI 29 LT ÇIKAR
SPEED X 1000 30 LT ALTINDA OLDUĞU İÇİN SİSTEM NORMAL
ÇALIŞACAKTIR

ACCORDING TO FORMULA OIL QUANTITY WILL NOT EXCEED 30 LT PER


MILE AND SYSTEM KEEP ACTIVATING NORMALLY.