Job Truss QTY Customer Date Design Status

Galle_L_30_1 008 7 06-12-2010 PASS


Fabricator: Supracadd 6.071-07 TRUSS8 (Channel-truss design to AS4600) vers B.78
0 1594 3187 4781 6374 7968 9561
1594 1593 1594 1593 1594 1593

Type = CHANNEL smart: YES


Pitch = 26 flush: NO
SC-APEX-C-100-10-3
20

4 8

2 6

1
SC-HEEL-A-100-10-3 90
SC-HEEL-A-100-10-3
3 5 9 7

0 1912 3824 5737 7649 9561


1912 1912 1913 1912 1912

UNFACTORED SPACING = 1200 DEFL mm Locn span/d WEB JOINT CAPACITY (kN)
LOADING (kPa) CODE = AS4600-2005 Vert(DL) -1.8 5-9 999 SC-WEB-10-10-1 = T5.21/C5.21
TCLL 0.25 (LIMIT-STATE) Vert(LL) -1.3 9-7 999
TCDL 0.2 Vert(TL) -4.2 9-7 999
BCLL 0 Horz(DL) 0.6 90 N/A
BCDL 0.09 Horz(LL) 0.4 90 N/A
PLL -1.1 kN Horz(TL) 1.3 90 N/A

WIND INFORMATION MAX LIMIT-STATE REACTIONS (kN)


This truss was designed to 40m/s Jnt Horiz Case Gravity Case Uplift Case
Limit State design wind speed (strength).
1 2.17 118 5.22 124 -4.21 113
90 0 121 5.22 124 -4.21 113

STEEL MEMBER SELECTION


TOP CHORD: C10010RA/G550 Design Yield-stress = 550 mPa
BOT CHORD: C10010RA/G550 Design Yield-stress = 550 mPa
Single webs: C7510ra/G550 3-2,4-3,5-4,20-5,7-6,8-7,9-8,20-9 Design Yield-stress = 550 mPa

CRITICAL MEMBER-FORCES
Top Chords Bottom Chords Web forces Web Conn
Nodes AF BM Pass Case Nodes AF BM Pass Case Nodes AF BM Pass Case Pass Case
(kN) (kNm) % (kN) (kNm) % (kN) (kNm) % %
2-1 -10 0.17 48 124 1-3 -6.9 0.07 35 113 2-3 -1.2 0 30 100 30 105
4-2 -9.8 0.1 44 124 3-5 -0.8 0.02 33 130 3-4 -2 0 73 113 45 124
20-4 -5.1 0.44 38 140 5-9 -0.3 0.01 33 130 4-5 -2.1 0 61 100 48 113
20-8 -5.1 0.44 38 141 9-7 -0.8 0.02 33 130 5-20 -2.7 0 91 113 60 124
8-6 -9.8 0.1 44 124 7-90 -6.9 0.07 35 113 9-20 -2.7 0 91 113 60 124
6-90 -10 0.17 48 124 8-9 -2.1 0 61 100 48 113
7-8 -2 0 73 113 45 124
6-7 -1.2 0 30 100 30 105
NOTES
1. Dimensions and Loadings specified by fabricator in this document to be verified by building designer.
Design is not to be used if loading criteria does not meet local building codes
2. Maximum uplift at supports to be resisted by suitable connection (tie-down) of truss to supporting wall.
Tie-downs are outside the scope of the design software.