You are on page 1of 1

VD for water at 60°F (V in fps, D in inches)

0.1 0.2 0.4 0.6 0.8 1 2 4 6 8 10 20 40 60 100 200 400 600 1000 2000 4000 6000 10000
|______________________________________________________________________________________________
| | | | | | | | | | | | | | | | | | | | | | | |
______________________________________________________________________________________________|
VD for atmospheric air at 60°F
2 4 6 8 10 20 40 60 100 200 400 600 1000 2000 4000 6000 10000 20000 40000 60000 100000
−1 | | | | | | | | | | | | | | | | | | | | | | | | |
10
__
Laminar → Critical ← Transition zone →← Complete turbulence, rough pipes, R > 3500/r, 1/√f = 1.14 − 2 log r
9 flow zone
0.07
8
0.06

0.05
7
0.045
0.04
6 0.035
0.03
5.5
0.025
5
0.02
Darcy−Weisbach friction factor f Í ÄÄÄÄ
2hDg

0.0175

Relative roughness r Í Ä (ε in ft, D in ft)


LV 2

4.5
0.015
0.0125
4
0.01

3.5 0.008

0.006

D
ε
3
0.004

0.003
2.5
Material ε (ft)
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄ 0.002
Riveted steel 0.003−0.03 0.0015
Concrete 0.001−0.01
2 Wood stave 0.0006−0.003 0.001
Cast iron 0.00085
0.0008
1.8 Galvanized iron 0.0005
Asphalted cast iron 0.0004 0.0006
Commercial steel 0.00015 Smooth pipes, r __= 0
1.6 __ 0.0004
Drawn tubing 0.000005
1/√f = 2 log(R √f ) − 0.8
1.4 Fluid at 60°F ν (ft2/s)
ÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄ 0.0002
Hagen−Poisseuille equation
Water 1.217e−005 R ≤ 2300, f = 64/R
Air (14.70 psia) 0.0001583
1.2 0.0001
Colebrook equation, R ≥ 2300 __
Latitude (WGS84) g (ft/s2) __

ÄÄÄÄÄÄÄÄÄÄÄÄÄÄ ÄÄÄÄÄÄÄÄÄÄ 1/√f = −2 log(r /3.7 + 2.51/(R √f )) r = 5e−006


5e−005
10
−2 0.0° Sea level 32.0877
45.5° Standard 32.1740 Continuity equation, Q = AV
90.0° Sea level 32.2578 A = π D 2/4, V = 4Q /(π D 2) 2e−005
9
r = 1e−006
1e−005
8
6 7 8 3 2 3 4 5 6 7 8 4 2 3 4 5 6 7 8 5 2 3 4 5 6 7 8 6 2 3 4 5 6 7 8 7 2 3 4 5 6 7 8 8
10 10 10 10 10 10
VD Metzger & Willard, Inc.
Moody Diagram Reynolds number R Í ÄÄ (V in fps, D in ft, ν in ft 2/s)
ν http://www.metzgerwillard.com