You are on page 1of 57

07 /17/2014

07 /17/2014
07 /17/2014

TECHNICAL REVIEW

: PLN

Project

INDUSTRIAL DIVISION
Qty

No
1

Description
Set
1

1
1

Set
1

Set
1

1
1

ELECTRIC FIRE PUMP NFPA-20 STANDARD


Cap. 144 M3/H @ 54 Meter Total Head
"Aurora" Horizontal Split Case
Model : 411-4x5x11D/Single Stage
Pump Material Design, Casing : Cast Iron, Impeller : Bronze,
Shaft : Carbon Steel with Bronze Sleeve, Shaft Seal : Gland Packing
"Western" Electric Motor 37 kW @ 2915 Rpm
With 380V/ 3Ph/ 50Hz
"Ronald" Electric Fire Pump Controller
Auto On / Manual Off
DIESEL FIRE PUMP NFPA-20 STANDARD
Cap. 144 M3/H @ 54 Meter Total Head
"Aurora" Horizontal Split Case
Model : 411-4x5x11D/single stage
Pump Material Design, Casing : Cast Iron, Impeller : Bronze,
Shaft : Carbon Steel with Bronze Sleeve, Shaft Seal : Gland Packing
"CLARKE" Diesel Engine JU4H-NL14, 58 kW @ 3000 Rpm
Heat Exchanger Cooling System
Engine accessories : Batteries Cables, Silencer,
Flexible Exhaust Connector, Fuel Tank (Supplied by Local)
"Ronald" Diesel Fire Pump Controller
Auto On / Manual Off
JOCKEY PUMP
Cap. : 25 GPM @ 60 Meter Total Head
"Aurora" Vertical Multistage In-Line
Model : PVM 5-13
Pump Material Design, Casing : Stainless Steel, Impeller : Stainless
Steel, Shaft : Stainless Steel, Shaft Seal : Mechanical Seal
"Factory Choice" Motor 2.2 kW @ 2915 Rpm
with 380V/ 3Ph/ 50Hz
"Ronald" Jockey Fire Pump Controller

Page 1 of 1

REFERENCE LIST AURORA PUMP


IN INDONESIA
NO

PROJECT NAME

LOCATION

LINE

DUTY

YEAR

HINDOLI

PALEMBANG

BUILDING

FIRE PUMP

1988

SEMEN CIBINONG

CIBINONG

INDUSTRY

FIRE PUMP, TRANSFER PUMP

1999

MACRO

DENPASAR

BUILDING

FIRE PUMP

1999

BATU HIJAU WTP SECTION I

PLAZA DAGO

MAKRO

JAKARTA

BUILDING

FIRE PUMP

1999

MAKRO

MEDAN

BUILDING

FIRE PUMP

2000

SCHLUMBERGER

BALIKPAPAN

BUILDING

FIRE PUMP

2000

BANDUNG

MINING

FIRE PUMP

1999

BUILDING

FIRE PUMP

1999

BATU HIJAU WTP SECTION II

MINING

FIRE PUMP

2000

10

MULAWARMAN UNIV. PACKAGED I

BUILDING

FIRE PUMP

2000

11

MULAWARMAN UNIV. PACKAGED II

BUILDING

FIRE PUMP

2000

12

MULAWARMAN UNIV.PACKAGED III

BUILDING

FIRE PUMP

2000

13

GS BATTERY

FACTORY

FIRE PUMP

2000

JAKARTA

14

AUTO 2000 TEBET

JAKARTA

SHOWROOM

FIRE PUMP

2001

15

GLOBAL AGROTEK

JAKARTA

BUILDING

FIRE PUMP

2002

16

MALL FANTASI

BALIKPAPAN

BUILDING

FIRE PUMP

2002

17

TEMPO

MEDAN

WAREHOUSE

FIRE PUMP

2002

18

SUSU CAIR INDOMILK

FACTORY

FIRE PUMP

2002

19

PRESIDEN HOTEL

JAKARTA

BUILDING

FIRE PUMP

2002

20

BINTARO TRADE CENTER

JAKARTA

BUILDING

FIRE PUMP

2003

21

MALL KAREBOSI

MAKASSAR

BUILDING

FIRE PUMP

2003

22

MULIA TOWER

JAKARTA

BUILDING

FIRE PUMP

2003

23

BNI46 LADA

JAKARTA

BUILDING

FIRE PUMP

2003

24

EXSPAN KAJI

JAKARTA

BUILDING

FIRE PUMP

2003

25

WTC MANGGA DUA

JAKARTA

BUILDING

PLUMBING

2003

26

TAMAN IMPIAN JAYA ANCOL

JAKARTA

BUILDING

FIRE PUMP

2003

27

SEMEN CIBINONG

CIBINONG

CEMENT INDUSTRY

SEWAGE PUMP

2003

28

PANGRANGO PLAZA

BOGOR

BUILDING

FIRE PUMP

2003

29

ACA

BANDUNG

BUILDING

FIRE PUMP

2003

30

ITC KEBON KELAPA

BANDUNG

MARKET

FIRE PUMP

2003

WAREHOUSE

WATER IN TAKE VERTICAL


TURBINE

2004

31

PUPUK KUJANG

CIKAMPEK

32

MATA PELANGI OFFICE

JAKARTA

BUILDING

FIRE PUMP

2004

33

BSD MARKET

TANGERANG

BUILDING

FIRE PUMP

2004

34

TOTAL INDONESIA

MINING

PROCESS PUMP

2004

35

GRAND SOLO MALL

SOLO

BUILDING

FIRE PUMP

2004

36

CIPUTRA SERAYA MALL

PEKANBARU

BUILDING

FIRE PUMP

2004

37

PUSAT DAGANG INVESTASI

38

BELLAGIO RESIDENCE

JAKARTA

BUILDING

FIRE PUMP

2004

39

PONDOK INDAH MALL 2

JAKARTA

BUILDING

FIRE PUMP, CHILLER PUMP

2004

40

SAN MIGUEL

JAKARTA

FACTORY

FIRE PUMP

2004

41

BAYER

MEDAN

FACTORY

FIRE PUMP

2005

42

BAYER

SURABAYA

FACTORY

FIRE PUMP

2005

43

MEGA GLODOK KEMAYORAN

JAKARTA

BUILDING

FIRE PUMP

2005

44

SEMEN PADANG

PADANG

CEMENT INDUSTRY

COOLING TOWER

2005

45

SEMEN CIBINONG

CIBINONG

CEMENT INDUSTRY

WATER INJECTION

2005

46

SEMEN CIBINONG

CIBINONG

CEMENT INDUSTRY

WATER SPRAY

2005

47

PERTAMINA PRABUMULIH

PRABUMULIH

OIL & GAS

FIRE PUMP

2005

FIRE PUMP

2005

48
49

BATAM

BG JUNCTION / BUBUTAN

BUILDING

SURABAYA

FIRE PUMP

BUILDING

CHILLER & BOOSTER

FACTORY

VERTICAL TURBINE
PUMP

2004

2005
FIRE

50

BAYER

JAKARTA

2005

51

BPKP PRAMUKA

JAKARTA

BUILDING

FIRE PUMP

2005

52

BATAM CITY SQUARE

BATAM

BUILDING

FIRE PUMP

2005

53

MECOINDO

CIKARANG

FACTORY

FIRE PUMP

2006

54

OIL & GAS

FIRE PUMP

2006

55

GRIYA JENGGALA

JAKARTA

RESIDENTIAL

FIRE PUMP

2006

56

SUDIRMAN PARK

JAKARTA

BUILDING

FIRE PUMP

2006

57

PEARL GARDEN

JAKARTA

BUILDING

FIRE PUMP

2006

58

MODERN GOLF APARTEMENT

TANGERANG

BUILDING

FIRE PUMP

2006

59

CITY HOME KLP. GADING

JAKARTA

BUILDING

FIRE PUMP

2006

60

ISLAMIC CENTER

JAKARTA

BUILDING

FIRE PUMP

2006

61

INDONESIA NS FACTORY

JAKARTA

FACTORY

FIRE PUMP

2006

62

PLAZA CIBUBUR

JAKARTA

BUILDING

FIRE PUMP

2006

63

SUDIRMAN PLAZA

JAKARTA

BUILDING

FIRE PUMP

2006

64

WISMA 76

JAKARTA

BUILDING

FIRE PUMP

2006

65

GRAND INDONESIA

JAKARTA

BUILDING

FIRE PUMP, CHILLER PUMP,


PLUMBING PUMP

2006

66

NUSA 2 GOLF RESIDENT

BALI

BUILDING

FIRE PUMP

2006

68

PT. PJB UP MUARAKARANG

JAKARTA

POWER PLANT

FIRE PUMP

2006

69

LAMONGAN INTEGRATED
SHORE BASE

LAMONGAN

SHORE BASE
- WAREHOUSE

FIRE PUMP

2006

70

UPH KARAWACI

TANGERANG

BUILDING

FIRE PUMP

2006

71

XL PEKAN BARU

PEKAN BARU

BUILDING

FIRE PUMP

2006

72

DSS PROJECT

JAKARTA

FACTORY

FIRE PUMP

2006

73

SKF INDONESIA

JAKARTA

FACTORY

FIRE PUMP

2006

74

JOHNSON & SON PROJECT

JAKARTA

FACTORY

FIRE PUMP

2006

75

SENTRA GROSIR

CIKARANG

BUILDING

FIRE PUMP

2006

76

SEMEN BASOWA

SULAWESI

CEMENT INDUSTRY

REGENERATIVE TURBIN PUMP

2006

77

GRAND INDONESIA

JAKARTA

BUILDING

FIRE PUMP

78

KEDUTAAN BELANDA

JAKARTA

BUILDING

FIRE PUMP

BUILDING

VERTICAL TURBINE
PUMP

2006
2006
FIRE

79

HARDA BANK

JAKARTA

2006

80

MENARA PRIMA

JAKARTA

BUILDING

FIRE PUMP

2006

81

WISMA PONDOK INDAH

JAKARTA

BUILDING

FIRE PUMP, CHILLER PUMP

2006

82

SEMEN PADANG

PADANG

CEMENT INDUSTRY

HVAC PUMP

2006

83

ITC KOPO

BANDUNG

BUILDING

FIRE PUMP

2006
2006

84

THE EAST

JAKARTA

BUILDING

FIRE & CHILLER PUMP

85

PERTAMINA SAGATA

KALIMANTAN

OIL & GAS

FIRE PUMP

2006
2006

86

HOLCIM INDONESIA

JAKARTA

CEMENT INDUSTRY

REGENERATIVE TURBINE PUMP

87

SPRING HILL GOLF RESIDENCE

JAKARTA

RESIDENTIAL

FIRE PUMP

2006

88

HOLCIM INDONESIA

JAKARTA

CEMENT INDUSTRY

REGENERATIVE TURBINE PUMP

2006

89

JACC

JAKARTA

BUILDING

FIRE PUMP

2006

90

ETERNIT GRESIK

GRESIK

FACTORY

FIRE PUMP

2006

91

PLAZA ASIA TASIKMALAYA

TASIKMALAYA

BUILDING

CHILLER PUMP

2006

92

IPEKA SCHOOL

JAKARTA

BUILDING

FIRE PUMP

2006

93

PLAZA ASIA TASIKMALAYA

TASIKMALAYA

BUILDING

94

TOYOTA ASTRA MOTOR

JAKARTA

FACTORY

PLUMBING PUMP
SUBMERSIBLE PUMP
DEEP WELL PUMP
FIRE PUMP

95

CARREFOUR CIBINONG

BANDUNG

BUILDING

FIRE PUMP

2007

96

CARREFOUR KIARA CONDONG


MALL

BANDUNG

BUILDING

FIRE PUMP

2007

97

PERFETI VAN MELLE

JAKARTA

FACTORY

FIRE PUMP

2007

98

DATA CENTER

SURABAYA

BUILDING

FIRE PUMP

2007

99

TOYOTA ASTRA MOTOR

JAKARTA

FACTORY

CHILLER PUMP

2007
2007
2007

2007
2007

100

GRAND INDONESIA

JAKARTA

BUILDING

CHILLER PUMP APARTMENT,


CONVENTION HALL

101

CNOOC

OFFCHORE

OFFSHORE OIL RIG

VERTICALTURBINE
SEA WATER FIRE PUMP

102

PASAR BARU SQUARE

BALIKPAPAN

HOTEL AND MALL

FIRE PUMP

2007

103

SEMEN PADANG

PADANG

CEMENT INDUSTRY

HVAC PUMP

2007

104

NESTLE - PASURUAN

PASURUAN

FACTORY

FIRE PUMP

2007

FIRE PUMP, CHILLER PUMP


PLUMBING PUMP, DEEP WELL
PUMP

2007

105

ST. REGIS BALI

BALI

BUILDING

106

CARREFOUR RUNGKUT

SURABAYA

BUILDING

FIRE PUMP

2007

107

PABRIK SUGIZINDO

CIBINONG

FACTORY

FIRE PUMP

2007

108

SEK-NEG DIKLAT CIPETE

JAKARTA

BUILDING

FIRE PUMP

2007

109

THE CITY TOWER

JAKARTA

OFFICE

FIRE PUMP

2007

110

KEM TOWER KEMAYORAN

JAKARTA

BUILDING

FIRE PUMP

2007

111

WATERPLACE RESIDENCE

SURABAYA

BUILDING

FIRE PUMP

2007

112

SEASON CITY

JAKARTA

BUILDING

FIRE PUMP

2007

113

HOTEL MALEOSAN

MANADO

BUILDING

FIRE PUMP

2007

114

APARTMENT BSB

BALIKPAPAN

BUILDING

FIRE PUMP

2007

115

HOLCIM INDONESIA

JAKARTA

BUILDING

WATER SPRAY

2008

116

GRAHA 165

JAKARTA

BUILDING

CHILLER PUMP

2008

117

ARKADIA OFFICE

JAKARTA

BUILDING

FIRE PUMP

2008

118

SAINATH OFFICE

JAKARTA

BUILDING

FIRE PUMP

2008

119

GRAND CITY SURABAYA

SURABAYA

BUILDING

CHILLER PUMP

2008

120

KEM TOWER KEMAYORAN

JAKARTA

BUILDING

PLUMBING PUMP,
CHILLER PUMP,
SUBMERSIBLE PUMP

2008
2008

121

THE ADHIWANGSA RESIDENCE

SURABAYA

RESIDENTIAL

FIRE PUMP

122

DAPENRA

JAKARTA

BUILDING

FIRE PUMP

2008

123

LUCKY SQUARE MALL

BANDUNG

BUILDING

FIRE PUMP

2008

124

BEST WESTERN BALI HOTEL

BALI

BUILDING

FIRE PUMP

2008

125

ASTON VERANDA HOTEL

JAKARTA

BUILDING

FIRE PUMP

2008

126

SEMEN PADANG

PADANG

CEMENT INDUSTRY

HVAC PUMP

2008

127

HOLCIM INDONESIA

CILACAP

CEMENT INDUSTRY

WATER SPRAY

2008

128

CYBER-2

JAKARTA

OFFICE

FIRE PUMP

2008

129

HOTEL HILTON

BANDUNG

HOTEL

FIRE PUMP

2008

130

SUDIRMAN TOWER

JAKARTA

BUILDING

FIRE PUMP

2008

131

FREEPORT

IRIAN JAYA

MINING

CIRCULATION PUMP

2008

132

GRAHA PENA

SURABAYA

BUILDING

FIRE PUMP

2008

133

BPK PENABUR - KELAPA GADING

JAKARTA

BUILDING

FIRE PUMP

2008

134

FLOUR MILLS - CILEGON

CILEGON

FACTORY

FIRE PUMP

2008

135

MEDCO ENERGI

SUMATERA

OIL & GAS

FIRE PUMP

2008

136

PARAGON CITY

SEMARANG

BUILDING

FIRE PUMP

2008

137

MENARA MTH

JAKARTA

BUILDING

FIRE PUMP

2008

138

QATAR EMBASSY

JAKARTA

BUILDING

FIRE PUMP

2008

139

CYBER-2

JAKARTA

OFFICE

HVAC PUMP, PLUMBING PUMP

2008

140

MEDCO II

SUMATERA

OIL & GAS

FIRE PUMP

2008

141

CYBER ANNEX

JAKARTA

BUILDING

FIRE PUMP, HVAC PUMP,


PLUMBING PUMP

2008

142

RENOVASI GEDUNG MAHKAMAH


AGUNG, RI

JAKARTA

BUILDING

FIRE PUMP

2008

143

W HOTEL SEMINYAK

BALI

HOTEL

FIRE PUMP

2008

144

EQUITY TOWER

JAKARTA

BUILDING

FIRE PUMP

2008

145

DEPO PERTAMINA

BOJONEGORO

OIL & GAS

FIRE PUMP

2008

146

SEASON CITY

JAKARTA

BUILDING

HVAC PUMP

2008

147

DUFAN ANCOL

JAKARTA

BUILDING

FIRE PUMP

2008

148

TRANS KALLA

MAKASSAR

BUILDING

FIRE PUMP

2009

149

PUPUK KUJANG

CIKAMPEK

FACTORY

HYDROMATIC PUMP

2009

150

INDOSAT

SUKABUMI

BUILDING

FIRE PUMP

2009

151

IT BATAM

BATAM

BUILDING

FIRE PUMP

2009

152

SAMPOERNA STRATEGIC SQUARE

JAKARTA

BUILDING

HOT WATER PUMP

2009

153

KANTOR
SULUT

JAKARTA

BUILDING

FIRE PUMP

2009

154

LOMBOK AIRPORT

LOMBOK

BUILDING

FIRE PUMP

2009

155

LAN SAMARINDA

SAMARINDA

BUILDING

FIRE PUMP

2009

156

CENTRAL PARK

JAKARTA

BUILDING

HVAC PUMP

2009

157

OFFICE KRAMAT RAYA

JAKARTA

BUILDING

FIRE PUMP

2009

158

BINUS BOARDING HOUSE

JAKARTA

BUILDING

FIRE PUMP

2009

159

BANDARA KUALANAMU

MEDAN

BUILDING

FIRE PUMP, CHILLER


PLUMBING PUMP

160

PPPK PETRA

SURABAYA

BUILDING

FIRE PUMP

2009

161

PUSDIKLAT MAHKAMAH AGUNG

JAKARTA

BUILDING

FIRE PUMP

2009

162

WILMAR NABATI INDONESIA

GRESIK

INDUSTRY

FIRE PUMP

2009

163

PUSDIKLAT MAHKAMAH AGUNG

BOGOR

BUILDING

FIRE PUMP

2009

164

PERTAMINA ACEH EP RANTAU

ACEH

OIL & GAS

FIRE PUMP

2009

165

DINAS PEMADAM
LEBAK BULUS

JAKARTA

BUILDING

FIRE PUMP

2009

166

TEMPO SCAN TOWER

JAKARTA

BUILDING

FIRE PUMP, CHILLER


PLUMBING PUMP

167

CIK DITIRO APARTMENT

JAKARTA

BUILDING

FIRE PUMP

2010

168

CENTRAL PARK CGPP II

JAKARTA

BUILDING

CHILLER PUMP

2010

169

CENTRAL PARK BALL ROOM

JAKARTA

BUILDING

CHILLER PUMP

2010

170

SEASON CITY SCHOOL

JAKARTA

BUILDING

FIRE PUMP

2010

171

PERTAMINA UPMS IV DEPOT


SEMARANG
REWULU

OIL & GAS

FIRE PUMP

2010

172

PERTAMINA UPMS VII

MAKASAR

OIL & GAS

FIRE PUMP

2010

173

KEMANG VILLAGE SCHOOL

JAKARTA

BUILDING

FIRE PUMP

2010

174

KEMANG VILLAGE

JAKARTA

BUILDING

FIRE PUMP

2010

175

RUSUNAMI GADING ICON

JAKARTA

RESIDENTIAL

FIRE PUMP

2010

176

MENARA ALLIANZ

JAKARTA

BUILDING

FIRE PUMP

2010

177

PERTAMINA UPMS VII DEPOT


MAKASAR
MAKASAR

OIL & GAS

VERTICAL
PUMP

178

PERTAMINA UPMS III


BERUNG

BANDUNG

OIL & GAS

FIRE PUMP

2010

179

DPPU AVIASI KUALANAMU MEDAN

MEDAN

OIL & GAS

FIRE PUMP

2010

180

MEDCO ENERGY M-12 TARAKAN

KALIMANTAN

OIL & GAS

FIRE PUMP

2010

PERWAKILAN

PEMDA

KEBAKARAN-

UJUNG

TURBINE

PUMP,

PUMP,

FIRE

2009

2010

2010

KEMANG VILLAGE KVR & RITZ


JAKARTA
TOWER

BUILDING

FIRE PUMP

2010

182

CIPUTRA WORLD

SURABAYA

BUILDING

FIRE PUMP

2010

183

PERTAMINA
BALONGAN

BALONGAN

OIL & GAS

FIRE PUMP

2010

184

PERTAMINA UBEP TARAKAN

TARAKAN

OIL & GAS

FIRE PUMP

2010

185

DPPU SOEKARNO HATTA

CENGKARENG

OIL & GAS

VEHRTICAL SUMP PUMP

2010

186

HOTEL SENTRA KELAPA GADING

JAKARTA

BUILDING

PLUMBING

2010

187

ANCOL MENTION

JAKARTA

BUILDING

FIRE PUMP

2010

188

GEDUNG LEMIGAS CIPULIR

JAKARTA

BUILDING

FIRE PUMP

2010

189

MEDCO EOR RIMAU

PALEMBANG

OIL AND GAS

FIRE PUMP

2010

190

PERTAMINA EP PENDOPO

PRABUMULIH

OIL AND GAS

FIRE PUMP

2010

191

SUNTER OFFICE

JAKARTA

BUILDING

FIRE PUMP

2010

192

KAWASAN
NARAGONG

NARAGONG

BUILDING

FIRE PUMP

2010

193

KRAFT FOOD INDONESIA

CIKARANG

BUILDING

FIRE PUMP

2010

194

HANG LEKIR RESIDANCE

JAKARTA

BUILDING

FIRE PUMP

2010

195

CIPUTRA WORLD

SURABAYA

BUILDING

FIRE PUMP

2010

196

CENTRAL PARK

JAKARTA

HOTEL

FIRE PUMP

2011

197

RS. ADVENT BANDUNG

BANDUNG

BUILDING

FIRE PUMP

2011

198

MENARA CITICON

JAKARTA

BUILDING

FIRE PUMP

2011

199

BINUS SERPONG 3

JAKARTA

BUILDING

FIRE PUMP

181

UPMS

III

LPG

PERGUDANGAN

2011

200

NUSANTARA TURBINE PROPULSI

BANDUNG

INDUSTRY

VERTICAL
PUMP

201

GEDUNG BERSAMA GRAMEDIA

JAKARTA

BUILDING

FIRE PUMP

2011

202

TANGERANG CITY MALL

TANGERANG

BUILDING

CHILLER PUMP

2011

203

BOILER

YOGYAKARTA

INDUSTRY

BOILER PUMP

2011

204

GALERI MODECOR

JAKARTA

BUILDING

FIRE PUMP

2011

205

MALL OF KEDIRI

KEDIRI

BUILDING

FIRE PUMP

2011

206

PERTAMINA
BADAS

SURABAYA

OIL & GAS

VERTICAL
PUMP

207

PERTAMINA EP RANTAU

ACEH

OIL & GAS

FIRE PUMP

2011

208

MALL SERANG BANTEN

BANTEN

BUILDING

FIRE PUMP

2011

209

WHITZ HOTEL

SEMARANG

HOTEL

FIRE PUMP

2011

210

ST.MORITZ

JAKARTA

BUILDINGPRESIDENTIAL

FIRE PUMP

2011

211

ST.MORITZ

JAKARTA

BUILDINGAMBASSADOR

FIRE PUMP

2011

212

SWISS BELL HOTEL

BALI

HOTEL

FIRE PUMP

2011

UPMS

DEPOT

TURBINE

TURBINE

FIRE

FIRE

2011

2011

213

REGENT HOTEL

BALI

214

KAMPUNG ITSB

CIKARANG

215

BANK RIAU

216

HVAC

2011

BUILDING

FIRE PUMP

2011

RIAU

BUILDING

FIRE PUMP

2011

THE STONE BALI

BALI

BUILDING

FIRE PUMP

2011

217

WISMA PONDOK INDAH III

JAKARTA

BUILDING

FIRE PUMP, PLUMBING PUMP,


CHILLER PUMP, SUBMERSIBLE
PUMP

2011

218

HOTEL NOVOTEL GAJAH MADA

JAKARTA

HOTEL

FIRE PUMP, CHILLER PUMP

2011

219

APARTMENT
MADA

JAKARTA

RESIDENTIAL

FIRE PUMP

2011

220

APARTMENT RUSUNAMI SUNTER


JAKARTA
PARK VIEW

RESIDENTIAL

FIRE PUMP

2011

RESIDENTIAL

FIRE PUMP

2011

RESIDENTIAL

FIRE PUMP

2011

221
222

NOVOTEL

GAJAH

APARTMENT RUSUNAMI PURI PARK


JAKARTA
VIEW TOWER A,B & C
APARTMENT RUSUNAMI PURI PARK
JAKARTA
VIEW TOWER E

HOTEL

223

GAJAH MADA PLAZA

JAKARTA

BUILDING

CHILLER PUMP

2011

224

GUDANG DHL

JAKARTA

BUILDING

FIRE PUMP

2011

225

IRMC SHOWROOM & OFFICE

JAKARTA

BUILDING

FIRE PUMP

2011
2011

226

GREEN BAY PLUIT TAHAP I

JAKARTA

BUILDING

PLUMBINGPUMP, SUBMERSIBLE
PUMP

227

HOTEL TRANS & IBIS

BANDUNG

BUILDING

FIRE PUMP, CHILLER PUMP

2011

228

PERTAMINA EP KTI PAPUA

SORONG

OIL & GAS

FIRE PUMP

2011

229

PERTAMINA JAYAPURA DEPOT


PAPUA
SORONG

OIL & GAS

FIRE PUMP

2011

230

ASAM ASAM COAL MINING

KALIMANTAN

MINING

FIRE PUMP

2011

231

LOGO OFFICE

JAKARTA

BUILDING

FIRE PUMP

2011

232

HOLIDAY INN SUNTER

JAKARTA

HOTEL

FIRE PUMP, PLUMBING PUMP,


CHILLER PUP

2011

233

HOLIDAY INN SUNTER

JAKARTA

RUKAN

FIRE PUMP, PLUMBING PUMP

2011

234

GUDANG GARAM TOWER

JAKARTA

BUILDING

FIRE PUMP

2011

235

MEDAN CENTER POINT

MEDAN

BUILDING

FIRE PUMP

2011

236

PERTAMINA UPMS
TANJUNG PERAK

SURABAYA

OIL & GAS

FIRE PUMP

2011

237

SUJ INDOCHEM CILEGON

CILEGON

FACTORY

FIRE PUMP

2011

238

ARMADA JOHNSON CONTROL

CIKAMPEK

FACTORY

FIRE PUMP

2011

239

PERTAMINA
DEPOT

MAKASAR

OIL & GAS

JOCKEY PUMP

2011

240

PLTA BRANTAS

SURABAYA

POWER PLANT

FIRE PUMP

2011

241

PERTAMINA EP PENDOPO

PRABUMULIH

OIL & GAS

FIRE PUMP

242

PERTAMINA
SEMAMPIR

OIL & GAS

VERTICAL
PUMP

MAKASAR

UPMS

LPG

MULTI

DEPOT

SURABAYA

2011
TURBINE

FIRE

2011

243

PERTAMINA LPG TANJUNG PRIOK

JAKARTA

OIL & GAS

FIRE PUMP

2011

244

PERTAMINA
KUPANG

SURABAYA

OIL & GAS

FIRE PUMP

2011

245

PERTAMINA UBEB TANJUNG

KAL-SEL

OIL & GAS

FIRE PUMP

2011

246

PABRIK ROKOK GUDANG GARAM

SEMARANG

FACTORY

FIRE PUMP

2011

247

GEDUNG AUDITORIUM PT. AHM

CIKARANG

FACTORY

FIRE PUMP

2011

248

U RESIDENCE

JAKARTA

BUILDING

FIRE PUMP

2011

249

CIKINI GOLD CENTER

JAKARTA

BUILDING

FIRE PUMP

2011

250

WEST MARK APARTMENT

JAKARTA

RESIDENTIAL

FIRE PUMP

2011

251

GREEN BAY PLUIT TAHAP-1A

JAKARTA

BUILDING

FIRE PUMP

2011

252

GEDUNG EXIM MELATI

JAKARTA

BUILDING

CHILLER PUMP

2011

253

APM ARMADA AUTO PARTS

CIKARANG

FACTORY

FIRE PUMP

2011

254

PERTAMINA
FIELD CEPU

CEPU

OIL & GAS

FIRE PUMP

255

SRC FACTORY KARAWANG

KARAWANG

FACTORY

FIRE PUMP

2012

256

PT. TEMPO JL. KEMUNING

JAKARTA

FACTORY

FLOOD PUMP

2012

257

PERTAMINA
MAUMERE

SURABAYA

VERTICAL TURBINE- FIRE PUMP

2012

258

OTTO PHARMACEUTIAL

BANDUNG

FACTORY

FIRE PUMP

2012

259

PERTAMINA JAYAPURA DEPOT


JAYAPURA
DOBO, TUAL & MERAUKE

OIL & GAS

FIRE PUMP

2012

260

MEDCO M12 TARAKAN

SUMATERA

OIL & GAS

FIRE PUMP

2012

261

PERTAMINA PERTAGAS SUMATERA SUMATERA

OIL & GAS

FIRE PUMP

2012

262

PERTAMINA PRABUMULIH

OIL & GAS

FIRE PUMP

2012

263

PERTAMINA UPMS III JBB DEPOT


TASIKMALAYA
TASIKMALAYA

OIL & GAS

FIRE PUMP

2012

264

PERTAMINA MAKASSAR DEPOT


MAKASSAR
GORONTALO

OIL & GAS

FIRE PUMP

2012

265

PERTAMINA BITUNG

MAKASSAR

OIL & GAS

JOCKEY PUMP

2012

266

PERTAMINA UPMS
PADALARANG

JAWA BARAT

OIL & GAS

FIRE PUMP

2012

267

CNG SEI GELAM

JAMBI

OIL & GAS

FIRE PUMP

2012

268

PERTAMINA BIAK, JAYAPURA

JAYAPURA

OIL & GAS

FIRE PUMP

2012

269

PERTAMINA SEMARANG CILACAP

JAWA TENGAH

OIL & GAS

FIRE PUMP

2012

270

PERTAMINA REWULU

JOGJA

OIL & GAS

JOCKEY PUMP

2012

271

SUGAR
REFINERY
JAKARTA

JAKARTA

FACTORY

FIRE PUMP

2012

272

SUJ CILEGON

CILEGON

FACTORY

FIRE PUMP

2012

273

INDOFOOD CIKUPA - TANGERANG

TANGERANG

FACTORY

FIRE PUMP

2012

UPMS

EP

DPPU

REGION

JAWA

SURABAYA-DEPOT

III

SUMATERA

DEPOT

MARUNDA

OIL & GAS

2012

274

PERTAMINA BALIKPAPAN

KALIMANTAN

OIL & GAS

JOCKEY PUMP

2012

275

REGENT HOTEL

BALI

BUILDING

CHILLER PUMP

2012

276

BANK MEGA CARD CENTER

JAKARTA

BUILDING

FIRE PUMP

2012

277

PUSAT TIKI-JNE

JAKARTA

BUILDING

FIRE PUMP

2012

278

KEMANG VILLAGE INFINITY-TOWER JAKARTA

BUILDING

FIRE PUMP

2012

279

KEMANG
TOWER

JAKARTA

BUILDING

FIRE PUMP

2012

280

DHARMAWANGSA 101 HOTEL

JAKARTA

BUILDING

FIRE PUMP

2012
2012

VILLAGE

INTERCON

281

MENARA PRIMA II

JAKARTA

BUILDING

CHILLER PUMP, SUBMERSIBLE


PUMP

282

RS. AKADEMIKA UGM

JOGYAKARTA

BUILDING

FIRE PUMP

2012

283

HOTEL AMARIS NUSA 2

BALI

BUILDING

FIRE PUMP

2012

284

TRANS STUDIO

BANDUNG

BUILDING

CIRCULATION PUMP

2012

285

THE WINDSOR APARTMENT

JAKARTA

BUILDING

FIRE PUMP

2012

286

STREET GALERY PONDOK INDAH

JAKARTA

BUILDING

FIRE
PUMP

287

GREEN BAY TAHAP II - MALL

JAKARTA

BUILDING

FIRE PUMP

2012

288

PULOMAS PARK CENTER

JAKARTA

BUILDING

FIRE PUMP

2012

289

AKADEMI PERKERETAAPIAN

MADIUN

BUILDING

FIRE PUMP

2012

290

BANDARA SULTAN THAHA

JAMBI

BUILDING

FIRE PUMP

2012

291

BANDARA DEPATI AMIR

BANGKA BELITUNG

BUILDING

FIRE PUMP, PLUMBING PUMP

2012

292

PASAR SINPASA

BEKASI

BUILDING

FIRE PUMP

2012

293

HOLIDAY INN EXPRESS

BALI

BUILDING

FIRE PUMP

2012

294

GREEN LAKE SUNTER-TAHAP I

JAKARTA

BUILDING

FIRE PUMP

2012

295

DSO DJARUM TANDES SURABAYA

SURABAYA

FACTORY

FIRE PUMP

2013

296

BALI DESA NUSA DUA

BALI

BUILDING

FIRE PUMP

2013

297

BANDARA DJUANDA

SURABAYA

BUILDING

FIRE PUMP

2013

298

SIMPRUG BOTANICA

JAKARTA

BUILDING

FIRE PUMP

2013

299

MENARA PRIMA 2

JAKARTA

BUILDING

PLUMBING PUMP

2013

300

CONDOTEL AWANA

BALI

BUILDING

FIRE PUMP

2013

301

SHANGRILA HOTEL

BALI

BUILDING

FIRE PUMP

2013

302

PERTAMINA BALIKPAPAN DEPOT


BALIKPAPAN
SAMARINDA

OIL & GAS

JOCKEY PUMP

2013

OIL & GAS

FIRE PUMP

2013

OIL & GAS

FIRE PUMP

2013

303
304

PERTAMINA BALIKPAPAN DEPOT


PANGKALAN BUN, DEPOT PULAU BALIKPAPAN
PISAU, DPPU JUWATA
PERTAMINA BALIKPAPAN DEPOT
BALIKPAPAN
SINTANG

PUMP,

SUBMERSIBLE

2012

305

PERTAMINA BALIKPAPAN DEPOT


BALIKPAPAN
TARAKAN

OIL & GAS

VERTICAL
PUMP

TURBINE

FIRE

306

PERTAMINA BALIKPAPAN DEPOT


BALIKPAPAN
BANJARMASIN

OIL & GAS

VERTICAL
PUMP

TURBINE

FIRE

307

HOTEL SANTIKA CIKARANG

CIKARANG

BUILDING

FIRE PUMP

2013

308

BALI NUSA
CENTER

BALI

BUILDING

FIRE PUMP

2013

309

GEDUNG BINA MULYA 1

JAKARTA

BUILDING

CHILLER PUMP

2013

310

TOWER PLN BEKASI

BEKASI

PLN

CIRCULATION PUMP

2013

311

PERTAMINA TBBM SERUI

PAPUA

OIL & GAS

FIRE PUMP

2013

312

FLOUR MILL CILEGON

CILEGON

INDUSTRI

FIRE PUMP

2013

313

PERTAGAS JAMBI TEMPINO

JAMBI

OIL & GAS

FIRE PUMP

2013

314

PERTAMINA SANGATTA

KALIMANTAN
TIMUR

OIL & GAS

FIRE PUMP

2013

315

THE MANSION @ DUKUH GOLF


JAKARTA
KEMAYORAN

BUILDING

FIRE PUMP

2013

316

PERTAMINA TJILIK RIWUT

KALIMANTAN
TENGAH

OIL & GAS

FIRE PUMP

2013

317

PERTAMINA LPG DUMAI

RIAU

OIL & GAS

FIRE PUMP

2013

318

PERTAMINA REGION IV SEMARANG


JAWA TENGAH
TBBM LOMANIS CILACAP

OIL & GAS

FIRE PUMP

2013

319

PERTAMINA EP FIELD TAMBUN

OIL & GAS

FIRE PUMP

2013

320

PERTAMINA
REGION
IV
SEMARANG-TBBM
LOMANIS JAWA TENGAH
CILACAP

OIL & GAS

JOCKEY PUMP

2013

321

PERTAMINA TBBM KAIMANA

PAPUA

OIL & GAS

FIRE PUMP

2013

322

PERTAMINA LABUHA

PAPUA

OIL & GAS

FIRE PUMP

2013

323

PERTAMINA UPMS VII SULAWESI


TBBM MOUTONG& TBBM BANGGAI,
TBBM LUWUK & TBBM POSO, TBBM SULAWESI
RAHA,
TBBM
POSO,
TBBM
MOUTONG & TBBM BANGGAI

OIL & GAS

FIRE PUMP

2013

324

PGN LAMPUNG

LAMPUNG

OIL & GAS

FIRE PUMP

2013

325

DSO DJARUM TANDES

JAWA TIMUR

INDUSTRI

FIRE PUMP

2013

326

PANTAI
HOTEL

JAKARTA

BUILDING

FIRE PUMP

2013

327

SAHID SUDIRMAN CENTER

JAKARTA

BUILDING

FIRE PUMP

2013

328

HARRIS HOTEL & YELLO HOTEL


JAKARTA
HAYAM WURUK

BUILDING

FIRE PUMP

2013

329

HOTEL HOLIDAY INN EXPRESS JAKARTA


CIKINI

BUILDING

FIRE PUMP

2013

330

MENTENG PARK

JAKARTA

BUILDING

FIRE PUMP

2013

331

HOTEL AMARIS PASAR MINGGU

JAKARTA

BUILDING

FIRE PUMP

2013

DUA

INDAH

CONVENTION

KAPUK

MAL

JAWA BARAT

&

10

2013
2013

332

HOTEL 101 LEGIAN

BALI

BUILDING

FIRE PUMP

2013

333

HOTEL 101 JOGYAKARTA

JOGYAKARTA

BUILDING

FIRE PUMP

2013

334

UPH KARAWACI

TANGERANG

BUILDING

FIRE PUMP

2013

335

BINTARO PARK VIEW

JAKARTA

BUILDING

FIRE PUMP

2013

336

HOTEL ALILA SCBD

JAKARTA

BUILDING

VERTICAL TURBINE
PUMP,
PLUMBING
SUBMERSIBLE PUMP

337

SOHO PODOMORO CITY

JAKARTA

BUILDING

FIRE PUMP

2014

338

WOLRD VISION INDONESIA

JAKARTA

BUILDING

FIRE PUMP

2014

339

LOBP BATAKAN BALIKPAPAN

KALIMANTAN
TIMUR

OIL & GAS

FIRE PUMP

2014

340

PERTAMINA TBBM NABIRE

PAPUA

OIL & GAS

FIRE PUMP

2014

341

PERTAMINA TBBM MASOHI

MALUKU TENGAH

OIL & GAS

VERTICAL TURBINE

2014

342

PABRIK PENGOLAHAN DAGING DI


JAWA BARAT
PURWAKARTA

INDUSTRI

FIRE PUMP

2014

343

HOTEL BEST WESTERN SOLO

SOLO

BUILDING

FIRE PUMP

2014

344

ELPIS RESIDENCE

JAKARTA

BUILDING

FIRE PUMP

2014

345

BANDARA SUPADIO

PONTIANAK

BUILDING

FIRE PUMP

2014

346

HOTEL 101 BOGOR

BOGOR

BUILDING

FIRE PUMP

2014

347

PURI INDAH FINANCIAL TOWER

JAKARTA

BUILDING

FIRE PUMP

2014

348

ONE BELPARK MALL

JAKARTA

BUILDING

FIRE PUMP

2014

349

BATULICIN

KALIMANTAN
SELATAN

OIL & GAS

VERTICAL TURBINE

2014

350

SENORO

SULAWESI TENGAH OIL & GAS

FIRE PUMP

2014

351

CENTRAL KITCHEN THE DUCK KING TANGERANG

INDUSTRI

FIRE PUMP

2014

352

GEDUNG GIS

JAKARTA

BUILDING

FIRE PUMP

2014

353

THE
MANSION
BOUGENVILLE

JAKARTA

BUILDING

FIRE PUMP

2014

354

MENARA SENTRAYA

JAKARTA

BUILDING

FIRE PUMP

2014

355

HOTEL BEDROCK

BALI

BUILDING

FIRE PUMP

2014

TOWER

11

FIRE
PUMP,

2013

356

GOR PKP CIRACAS

JAWA BARAT

BUILDING

FIRE PUMP

2014

357

GARDEN
WING
KARAWANG

JAWA BARAT

BUILDING

FIRE PUMP

2014

358

HOTEL
ASTON
CENTER, SENTUL

JAWA BARAT

BUILDING

FIRE PUMP

2014

359

PABRIK
PRINTING
SIDOARJO

JAWA TIMUR

INDUSTRI

FIRE PUMP

2014

360

PERTAMINA TBBM KOTA BARU &


KALIMANTAN
DEPOT LPG BALIKPAPAN

OIL & GAS

VERTICAL
PUMP

361

PABRIK DUA BERLIAN

JAKARTA

INDUSTRI

FIRE PUMP

2014

362

PERTAMINA
PLUMPANG

JAKARTA

OIL & GAS

FIRE PUMP

2014

363

PERTAMINA
FIELD

RIAU

OIL & GAS

FIRE PUMP

2014

364

PERTAMINA TBBM SANANA

MALUKU

OIL & GAS

VERTICAL TURBINE

2014

365

MAXX BOX

KARAWACI

BUILDING

FIRE PUMP

2014

366

HOTEL HARRIS BENOA

BALI

BUILDING

FIRE PUMP

2014

367

HOTEL TIJILI SEMINYAK

BALI

BUILDING

FIRE PUMP

2014

368

MALL & HOTEL PIK

JAKARTA

BUILDING

PLUMBING PUMP

2014

369

CONVENTION HALL

SAMARINDA

BUILDING

FIRE PUMP

2014

370

KAMPUS ITB TAHAP II

BANDUNG

BUILDING

FIRE PUMP

2014

371

PERTAMINA
BITUNG

SULAWESI

OIL & GAS

VERTICAL TURBINE

2014

372

PERTAMINA DPPU SAM RATULANGI


SULAWESI
MANADO

OIL & GAS

FIRE PUMP

2014

373

PERTAMINA FIELD TARAKAN

SULAWESI

OIL & GAS

FIRE PUMP

2014

374

PERTAMINA
KOLONEDALE

SULAWESI

OIL & GAS

JOCKEY PUMP

2014

375

PERTAMINA BALONGAN

BALONGAN

OIL & GAS

VERTICAL TURBINE

2014

376

PABRIK ETERNA GELORAPUTRA

CIKUPA

INDUSTRI

FIRE PUMP

2014

377

ANCOL DOUBLE DECKER

JAKARTA

BUILDING

FIRE PUMP

2014

378

CENTENIAL TOWER

JAKARTA

BUILDING

FIRE PUMP

2014

379

HOTEL ALILA SCBD

JAKARTA

BUILDING

VERTICAL
PUMP

APARTMENT
&

TRAINING
FLEXO

ELNUSA
EP

ASSET

AREA

DI

DEPO
1

LIRIK

SULAWESI

SULAWESI

12

TURBINE

FIRE

TURBINE-JOCKEY

2014

2014

380

OAK TOWER

JAKARTA

BUILDING

FIRE PUMP

2014

381

ST. REGIS - HOTEL

JAKARTA

BUILDING

FIRE PUMP

2014

382

ST. REGIS - OFFICE

JAKARTA

BUILDING

FIRE PUMP

2014

383

HOTEL GUNUNG GEULIS

BOGOR

BUILDING

FIRE PUMP

2014

384

NPK GRANULAR
KUJANG

CIKAMPEK

INDUSTRI

FIRE PUMP

2015

385

PGN

JAWA BARAT

OIL & GAS

FIRE PUMP

2015

386

PERTAMINA DEPOT SINTANG

KALIMANTAN
BARAT

OIL & GAS

FIRE PUMP

2015

387

PABRIK KERTAS

CIKARANG BARAT

INDUSTRI

FIRE PUMP

2015

388

PERTAMINA SANGA SANGA

KALIMANTAN

OIL & GAS

FIRE PUMP

2015

389

PABRIK ETERNIT GRESIK

JAWA TIMUR

INDUSTRI

FIRE PUMP

2015

390

PABRIK VALEO

PURWAKARTA

INDUSTRI

VERTICAL TURBINE & JOCKEY


PUMP

2015

391

HOTEL ARCS JAMBULUWUK

BALI

BUILDING

FIRE PUMP

2015

392

MEDAN
CENTER
POINT

MEDAN
APARTMENT CENTRUM & CENTRIA

BUILDING

FIRE PUMP

2015

393

MENARA PALMA II

JAKARTA

BUILDING

FIRE PUMP

2015

394

ST. MORITZ II - OFFICE TOWER

JAKARTA

BUILDING

FIRE PUMP

2015

395

PLAZA SADIRA

PEKANBARU

BUILDING

FIRE PUMP

2015

396

PERTAMINA FIELD TANJUNG

KALIMANTAN
SELATAN

OIL AND GAS

FIRE PUMP

2015

397

APARTMENT LA CITY

JAKARTA

BUILDING

FIRE PUMP

2015

398

HOTEL ARTOTEL SANUR

BALI

BUILDING

FIRE PUMP

2015

399

MARVEL CITY HOTEL & MALL

SURABAYA

BUILDING

CHILLED PUMP

2015

400

YAYASAN LIA CIBUBUR

JAKARTA

BUILDING

FIRE PUMP

2015

401

MENARA PERTIWI

JAKARTA

BUILDING

FIRE PUMP, PLUMBING PUMP &


HVAC PUMP

2015

402

PLAZA SADIRA

PEKANBARU

BUILDING

FIRE PUMP

2015

403

PIK HOTEL NOVOTEL & IBIS

JAKARTA

BUILDING

PLUMBING PUMP

2015

II

PT.

PUPUK

13

404

TAMANSARI HIVE OFFICE PARK

JAKARTA

BUILDING

FIRE PUMP

2015

405

HOTEL IBIS LEGIAN

BALI

BUILDING

FIRE PUMP

2015

406

JICT EXPANSION- PHASE 6,7,8 & 10

JAKARTA

BUILDING

FIRE PUMP

2015

407

CNG BANGKANAI

KALIMANTAN
TENGAH

OIL AND GAS

FIRE PUMP

2015

408

TARJUN

KALIMANTAN
SELATAN

INDUSTRI

FIRE PUMP

2015

409

TERMINAL LPG BANYUWANGI

JAWA TIMUR

OIL AND GAS

FIRE PUMP

2015

410

COAL FIRED
BABELAN

JAWA BARAT

OIL AND GAS

FIRE PUMP

2015

411

PERTAMINA BIAK

PAPUA

OIL AND GAS

VERTICAL TURBIN PUMP

2015

412

INDIAN OIL TANKING, KARIMUN,


RIAU
KEPRI

OIL AND GAS

FIRE PUMP

2015

413

INDOFOOD NOODLE NEW

CIREBON

INDUSTRI

FIRE PUMP

2015

414

GARDENIA CIBINONG

JAWA BARAT

INDUSTRI

FIRE PUMP

2015

415

COAL FIRED
BABELAN

JAWA BARAT

OIL AND GAS

ELECTRIC FIRE PUMP

2015

416

EPCI FOR LIMA POWER AND


SAFETY
SYSTEM
UPGRADE JAKARTA
PROJECT

OIL AND GAS

VERTICAL TURBIN PUMP

2015

417

PETRO KIMIA

JAKARTA

OIL AND GAS

FIRE PUMP

2015

418

PT.
INDOFOOD
MAKMUR

CIKAMPEK

INDUSTRI

CHILLER PUMP

2015

419

TRIVIUM APARTMENT

CIKARANG

BUILDING

FIRE PUMP

2015

420

HOTEL AMARIS SATRIO KUNINGAN

JAKARTA

BUILDING

FIRE PUMP

2015

421

HOTEL MAXONE

BALI

BUILDING

FIRE PUMP

2015

422

GCNM TOWER

JAKARTA

BUILDING

FIRE PUMP

2015

423

PONDOK INDAH HOTEL

JAKARTA

BUILDING

FIRE PUMP

2015

424

RESIDENCE PONDOK INDAH

JAKARTA

BUILDING

FIRE PUMP

2015

425

MENARA PERTIWI

JAKARTA

BUILDING

BOOSTER PUMP

2015

426

KEMENTERIAN KOMUNIKASI DAN


INFORMATIKA

JAKARTA

BUILDING

FIRE PUMP

2015

427

BINUS ANGGREK

JAKARTA

BUILDING

TRANSFER PUMP

2015

POWER

POWER

CBP

STATION,

STATION,

SUKSES

14

428

CNG MARINE

LOMBOK

OIL AND GAS

FIRE PUMP

2016

429

B-BRAUN INDO TAISEI

CIKAMPEK

INDUSTRI

FIRE PUMP

2016

430

MORTAR UTAMA

CIBITUNG

INDUSTRI

FIRE PUMP

2016

431

MORTAR UTAMA

GRESIK

INDUSTRI

FIRE PUMP

2016

432

EPCI PENGEMBANGAN DPPU


SEPINGGAN

BALIKPAPAN

OIL AND GAS

FIRE PUMP

2016

433

PALEMBANG

PALEMBANG

INDUSTRI

FIRE PUMP

2016

444

SORINI

SURABAYA

INDUSTRI

FIRE PUMP

2016

445

WAREHOUSE MODERN MARKET

CIKINI

INDUSTRI

FIRE PUMP

2016

446

PONDOK INDAH RESIDENCE

JAKARTA

BUILDING

FIRE PUMP

2016

447

CHEVRON INDONESIA COMPANY

BALIKPAPAN

OIL AND GAS

FIRE PUMP

2016

448

TANJUNG UBAN

KEPULAUAN RIAU

OIL AND GAS

VERTICAL TURBINE PUMP

2016

449

PERTAGAS PALEMBANG

PALEMBANG

OIL AND GAS

VERTICAL TURBINE PUMP

2016

15

INDUSTRIAL PUMPS

POWER
WWW.PENTAIR.COM

INDUSTRIAL PUMPS POWER

Applications
Applic
Cooling Tower Pumps
Pentairs tradition as a leader in
pumps
vertical turbine and split case
c
continues with the rugged an
and heavy
turbine
duty, family of Pentair vertical tu
and split case pump products,
designed to successfully operate in a multitude of
intake, liquid transfer,
water sources such as raw water intake
cooling water circulation, booster service, storm water,
volatile fluids,
flood control, marine, process services, volat
condensate, fuel pumps and mine dewatering.

Circulating Water Pumps


Strong. Dependable. Reliable.
Pentairs tradition of leadership continues with these
attributes in the manufacture of Vertical Mixed and Axial
Flow Propeller Pumps. Designed for moderate to high
volume fluid movement from moderate to low discharge
pressures, both product lines have excellent low NPHS
requirements and are only separated by the amount of head
or pressure to be developed.
The advantages of mixed flow pumps include
minimum footprint, no priming required. In addition,
vertical mixed flow pumps are easily adaptable
to various design codes, can be modified for changing
wear
hydraulic conditions, and generally experience less we
due to the lower operating speeds they require.
Pentair vertical axial flow propeller pump applications
applic
urban and
are found in a variety of markets including urb
industrial, irrigation,
rural municipal water, government, industr
and more.

Boiler Feed Pumps


With the 7600 series turbine
turbin pump Pentair brings its
century of experience to a pinnacle. The 7600 series pump
is a multistage, horizo
horizontal, radially split pump for high
pressure service.
fewer stages, 10+ point higher efficiencies
With 30-50% fe
allowing for the use of smaller motors and less power
consumption and available pressures up to 2000psi (1400 mlc),
consumpt
The 7600
760 series maximizes cost containment and other
operational efficiencies for the user.
oper

Contact your
local sales
representative
for availability.

Applications
Fire Water Pumps
Pentair, with its Fairbanks Nijhuis and
Aurora line of products, is the world leader
in UL/FM, NFPA 20 fire pumps in the world.
Vertical turbine, horizontal split case, vertically
mounted split case, inline and end suction
labeled fire pumps are available.

General Service Pumps


The Pentair Aurora line of end suction and ANSI Std. B73.1M pumps are
one of the most comprehensive product line offerings available. Vertical
mountings, in line mounting and even sump pumps are available with
Pentair Aurora pumps.
Both flanged and threaded connections are available
depending upon model.

Ash Sluice Pumps


Pumping fly ash in water suspension is tough duty for a pump.
Pentairs Fairbanks Nijhuis 4500/4600/4700
series high chrome iron, recessed impeller
pumps are up to the task.
They also can be used in other abrasive
services which require a 600+ Brinell
Hardness to resist wear and
premature failure.

WWW.PENTAIR.COM

INDUSTRIAL PUMPS POWER

Applications
Raw Water Intake Pumps
Pentairs Fairbanks Nijhuis and Aurora lines of
products have extensive experience in both vertical
turbine and horizontal split
case pumps in raw water intake
services. High reliability and
rugged construction
maximize service life
while high efficiencies
reduce power
consumption.

Condensate and Heater Drain Pumps


Pentairs vertical pumps are up to the task of pumping hot
condensate efficiently and reliability. Broad material selection is
based on properties of the condensate.
Low NPSHA impellers are available on many sizes to minimize
installation costs and suction vessel length.

Product quality, dependability, and innovation are all part of the Pentair
commitment to excellence. Whatever your needs, Pentair has you covered!

HORIZONTAL SPLIT CASE PUMP

AURORA 411 SERIES

VERTICAL SPLIT CASE PUMP

Built Per NFPA 20

SPLIT CASE FIRE PUMPS


WWW.AURORAPUMP.COM

SPLIT CASE FIRE PUMPS

AURORA 411 SERIES

Split Case Fire Pumps


Horizontal split case pumps are the most common type of fire
pump. These pumps are specifically designed and tested for
fire service applications where reliability of performance is of
vital importance. Split case pumps are characterized by:
(DV\DFFHVVWRDOOZRUNLQJSDUWV
5XJJHGFRQVWUXFWLRQ
/LEHUDOZDWHUSDVVDJHVDQG
(IILFLHQWRSHUDWLRQ
Split case fire pumps are specified when the source of water
is located above the surface of the ground and provides a
positive suction pressure to the pump at any performance point.
Single-stage or multistage pumps are available dependent upon
discharge pressure requirements.
Aurora split case fire pumps are built per the rigid standards of
NFPA 20 and are listed by Underwriters Laboratories (UL) and
approved by Factory Mutual (FM).
Available in a broad range of operating pressures and flows
from a minimum of 250 GPM, Aurora split case pumps can be
driven by either an electric motor or diesel engine. Auroras
8//LVWHG)0$SSURYHGILUHSXPSSDFNDJHVDOVRLQFOXGHWKH
system controller, with a full range of options and accessories
DYDLODEOHWRFRPSOHWHWKH1)3$FRPSOLDQWILUHSXPSSDFNDJH

In addition to horizontal split case pumps, Aurora also offers


split case performance in a vertical format. Vertical fire pumps
provide distinct advantages over horizontal pump constructions.
/HVVIORRUVSDFHLVUHTXLUHG
,QOLQHSLSLQJDUUDQJHPHQWDOORZVSLSLQJLQDQ\GLUHFWLRQ
in most cases.
(OHYDWHGPRWRUSURWHFWVDJDLQVWSRWHQWLDOIORRGLQJLIWKH
pump station is in a low area.
&RPSRQHQWVDUHUHJLVWHUILWWHGWRSUHYHQWPLVDOLJQPHQW

SPLIT CASE FIRE PUMPS

Pump Features

7
2
8

14

15

16
17

13

10
5
6

12

11

18

VERTICAL
SPLIT CASE

1.

Computer Machined

8.

major components with 360 degree registered


fits to assure concentricity of parts.

2.

Integral Bearing Arms

9.

4.

5.

11.

12.

holds shaft deflection to .002" at face of


stuffing box at maximum load.
WWW.AURORAPUMP.COM

Double Row Thrust

13.

Bearings
selected for 50,000 hour minimum life
at maximum load. Average bearing life
5 x minimum.

O-Ring Sealed Shaft Sleeves


prevent corrosion of the shaft. This eliminates
the need for stainless steel shafts.

16.

Case Wearing Rings


and throttle bushings protect the
casing from wear and are easily and
inexpensively replaced.

17.

Bronze Shaft Sleeve


prevents shaft wear, is slip fit over the shaft,
NH\ORFNHGDQGH[WHQGVWKHHQWLUHOHQJWK
of the seal box.

Grease Seals
DQGQRQVSDUNLQJQHRSUHQHURWDWLQJVOLQJHUV
protect both bearings during pump operation
and washdown.

Cast Iron Drip Rim Base

Short Bearing Span

Stuffing Boxes

ball bearing.

directs condensation and any stuffing box


OHDNDJHWRGUDLQ

7.

15.

DUHH[WUDGHHSIRUSURSHUVHDOLQJ6SOLWSDFNLQJ
JODQGVVLPSOLI\SDFNLQJPDLQWHQDQFH

Double Suction Impeller


balances hydraulic thrust loads.

6.

10.

Dynamically Balanced Impeller


LVNH\HGWRWKHVKDIWDQGVHFXUHGE\DGMXVWDEOH
shaft sleeves.

Interwoven, Graphite
Impregnated T.F.E.

Split Case Design


simplifies disassembly. The suction and
discharge piping and shaft alignment are
not disturbed.

GLDJRQDOO\FXWSDFNLQJULQJVVHDO
the pump shaft.

Enclosed Impeller Design


provides high efficiency and performance.

14.

between volute and stuffing box cannot


be damaged.

eliminate bearing misalignment and


simplify maintenance.

3.

Internal Water Seal Passages

HORIZONTAL
SPLIT CASE

18.

Certified Performance Test


with Positive Suction Pressure
is provided for each fire pump for customer
approval. Pumps are also hydrostatically tested
per NFPA 20 at no less than 250 psi.

Fire Pump Feature Selector


Standard

Optional

 %URQ]HILWWHGSXPSFRQVWUXFWLRQ

 'XFWLOHLURQFDVLQJV DYDLODEOHLQVHOHFWHGDQGPRGHOV

 %URQ]HVKDIWVOHHYHV

 5LJKWRUOHIWKDQGURWDWLRQ

 %URQ]HFDVHZHDULQJULQJV

 ,PSHOOHUZHDULQJULQJV

 '\QDPLFDOO\EDODQFHGLPSHOOHUV

 6WDLQOHVVVWHHOVKDIWV

 6WDLQOHVVVWHHOLPSHOOHUNH\

 'RXEOHURZEDOOEHDULQJVRQLQERDUGVLGH

 &DUERQVWHHOVKDIW

 ([WHUQDOE\SDVVOLQHIURPFDVLQJWRVWXIILQJER[HV
RSWLRQDORQ0RGHOVVWDQGDUGRQ0RGHOV

 &RUURVLRQUHVLVWDQWODQWHUQULQJV
 %URQ]HVWXIILQJER[EXVKLQJV
 %URQ]HJODQGV
 ,QWHUZRYHQJUDSKLWHLPSUHJQDWHG7)(SDFNLQJULQJV

 )RUPHGVWHHOGULSULPEDVH KRUL]RQWDOHOHFWULFGULYHQXQLWVRQO\
 
6XFWLRQOLIWWHVWWRYHULI\SHUIRUPDQFHDWRIUDWHGIORZ
 $YDLODEOHDFFHVVRULHVLQFOXGHYDOYHVKHDGHUVPDLQUHOLHIYDOYHV
increasers and reducers, waste cones, and more.

 &DVWLQWHJUDOEHDULQJDUPV PRVWPRGHOV
 5HJUHDVHDEOHEDOOEHDULQJV
 'RXEOHURZWKUXVWEHDULQJ RXWERDUGVLGH
 8SSHUFDVLQJOLIWLQJOXJV
 :DWHUVOLQJHUVDQGJUHDVHVHDOV
 +\GURVWDWLFDQG&HUWLILHG3HUIRUPDQFHWHVW
 &RXSOLQJJXDUG
 6XFWLRQDQGGLVFKDUJHJDXJHVZLWKVKXWRIIFRFNV

SUCTION
STANDARD
RIGHT-HAND ROTATION

(TOP VIEW HORIZONTAL PUMP)

SUCTION
VERTICAL PUMPS PROVIDE
IN-LINE PIPING IN ANY DIRECTION
(ALSO AVAILABLE RIGHT- OR LEFT-HAND)

OPTIONAL
LEFT-HAND ROTATION

(TOP VIEW HORIZONTAL PUMP)

 $XWRPDWLFDLUUHOHDVHYDOYH
 6WDQGDUGRQ0RGHOVIXUQLVKHGZKHQVXFWLRQSUHVVXUHLVEHORZSVLRQ0RGHOV
 7HVWLVSHUIRUPHGZLWKSRVLWLYHVXFWLRQSUHVVXUH

HY

UT

800 AIRPORT ROAD, NORTH AURORA, ILLINOIS 60542 WWW.AURORAPUMP.COM


Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.
AF-02-1033 11/26/12 2012 Pentair Ltd. All Rights Reserved.

ISO 9001

IT

AU
LIC

ST

DR

IN

19 17

ST
EGI

ER E D Q U

TY SYSTEM
ALI

 &DVLQJUHOLHIYDOYH HOHFWULFGULYHQXQLWVRQO\

qwertyuiopasdfghjklzxcvbnmqwertyui
opasdfghjklzxcvbnmqwertyuiopasdfgh
jklzxcvbnmqwertyuiopasdfghjklzxcvb
ELECTRIC
FIRE PUMP NFPA-20
nmqwertyuiopasdfghjklzxcvbnmqwer
SparePartListBook
ControllerModel:GPD
AURORA HORIZONTAL SPLIT CASE
tyuiopasdfghjklzxcvbnmqwertyuiopas
Model : 411-4x5x11D/Single Stage
dfghjklzxcvbnmqwertyuiopasdfghjklzx
cvbnmqwertyuiopasdfghjklzxcvbnmq
wertyuiopasdfghjklzxcvbnmqwertyuio
pasdfghjklzxcvbnmqwertyuiopasdfghj
klzxcvbnmqwertyuiopasdfghjklzxcvbn
mqwertyuiopasdfghjklzxcvbnmqwerty
uiopasdfghjklzxcvbnmqwertyuiopasdf
ghjklzxcvbnmqwertyuiopasdfghjklzxc
vbnmqwertyuiopasdfghjklzxcvbnmrty
uiopasdfghjklzxcvbnmqwertyuiopasdf
ghjklzxcvbnmqwertyuiopasdfghjklzxc

PERTAMINABALIKPAPANDEPOTPANGKALANBUN,
DEPOTPULANGPISAU,DPPUJUWATA

Preparedby:PT.RodaNurmala

PLN

Pump Data Sheet - AURORA PUMPS


Company: PT RODA NURMALA

EFP Cap. 144 M3/H @ 54 Meter Total Head

Name: PLN
Date: 6/17/2016

Pump:

Search Criteria:

Size: 4x5x11D

Flow: 634 US gpm

Type: 410 1 STG SPLIT CASE


Synch speed: 3000 rpm

Speed: 2950 rpm


Dia: 8.25 in

Curve: PC-193673

Impeller: 444A476

Specific Speeds:

Ns: 1060
Nss: 8457

Dimensions:

Suction: 5 in
Discharge: 4 in

Head: 177 ft

Secondary Operating Point: 951 US gpm, 140 ft


Fluid:
Water
Density: 62.32 lb/ft
Viscosity: 0.9946 cP

Temperature: 68 F
Vapor pressure: 0.3391 psi a
Atm pressure: 14.7 psi a

NPSHa: ---

Pump Limits:

Motor:

Temperature: 275 F
Pressure: 250 psi g
Sphere size: 0.56 in

Power: --Eye area: ---

634 US gpm

Head:

179 ft

Eff:

70%

Power:

40.4 hp

NPSHr:

9.37 ft

Size: 50 hp
Speed: 3000
Frame: 324T
Sizing criteria: Max Power on Design Curve

30

10.5 in

---- Data Point ---Flow:

Standard: NEMA
Enclosure: ODP

40

50

60

65

300

70
75

250
75

---- Design Curve ---205 ft

Shutoff dP:

88.7 psi

Min flow:

---

BEP:

70

8.25 in
200

Head - ft

Shutoff head:

75% @ 854 US gpm

NOL power:
48.8 hp @ 1298 US gpm

65
60

75
7.06 in
150

30

40

50

60

65

125 hp

25 70
hp

-- Max Curve --

100 hp
100

Max power:
117 hp @ 1671 US gpm

70

75 hp
60 hp
50 hp

65
60
50

NPSHr - ft

0
50

40 hp
30 hp

200

400

600

800

1000

1200

1400

1600

200

400

600

800

1000

1200

1400

1600

25

US gpm
Curve efficiencies are typical. For guaranteed values, contact Aurora Pump or your local distributor. Las eficiencias en
curvas son tipicas. Para valores garantizados contacte a Aurora Pump o a su distribuidor local.
Performance Evaluation:
Flow
US gpm

Speed
rpm

Head
ft

Efficiency
%

Power
hp

NPSHr
ft

761

2950

165

74

42.8

11.7

634

2950

179

70

40.4

9.37

507

2950

190

64

37.7

7.6

380

2950

198

54

34.7

7.4

254

2950

203

41

31.3

7.4

H2Optimize 10.6.1.0

Selected from catalog: Aurora Pumps 50 Hz Vers: 4.2

qwertyuiopasdfghjklzxcvbnmqwertyui
opasdfghjklzxcvbnmqwertyuiopasdfgh
jklzxcvbnmqwertyuiopasdfghjklzxcvb
DIESEL FIRE PUMP NFPA-20
nmqwertyuiopasdfghjklzxcvbnmqwer
SparePartListBook
ControllerModel:GPD
AURORA HORIZONTAL SPLIT CASE
tyuiopasdfghjklzxcvbnmqwertyuiopas
Model : 411-4x5x11D/Single Stage
dfghjklzxcvbnmqwertyuiopasdfghjklzx
cvbnmqwertyuiopasdfghjklzxcvbnmq
wertyuiopasdfghjklzxcvbnmqwertyuio
pasdfghjklzxcvbnmqwertyuiopasdfghj
klzxcvbnmqwertyuiopasdfghjklzxcvbn
mqwertyuiopasdfghjklzxcvbnmqwerty
uiopasdfghjklzxcvbnmqwertyuiopasdf
ghjklzxcvbnmqwertyuiopasdfghjklzxc
vbnmqwertyuiopasdfghjklzxcvbnmrty
uiopasdfghjklzxcvbnmqwertyuiopasdf
ghjklzxcvbnmqwertyuiopasdfghjklzxc

PERTAMINABALIKPAPANDEPOTPANGKALANBUN,
DEPOTPULANGPISAU,DPPUJUWATA

PLN

Preparedby:PT.RodaNurmala

Pump Data Sheet - AURORA PUMPS


Company: PT RODA NURMALA

DFP Cap. 144 M3/H @ 54 Meter Total Head

Name: PLN
Date: 6/20/2016

Pump:

Search Criteria:

Size: 4x5x11D

Flow: 144 m/hr

Type: 410 1 STG SPLIT CASE


Synch speed: 3000 rpm

Speed: 2950 rpm


Dia: 210 mm

Curve: PC-193673

Impeller: 444A476

Specific Speeds:

nq: 21
S: 164

Dimensions:

Suction: 125 mm
Discharge: 100 mm

Head: 54 m

Secondary Operating Point: 216 m/hr, 43 m


Fluid:
Water
Density: 998.3 kg/m
Viscosity: 0.9946 cP

Temperature: 20 C
Vapor pressure: 2.339 kPa a
Atm pressure: 101.4 kPa a

NPSHa: ---

Pump Limits:

Motor:

Temperature: 135 C
Pressure: 1724 kPa g
Sphere size: 14.2 mm

Power: --Eye area: ---

---- Data Point ---Flow:

144 m/hr

Head:

54.8 m

Eff:

71%

Power:

30.3 kW

NPSHr:

2.85 m

Standard: NEMA
Enclosure: ODP

Size: 37 kW
Speed: 3000
Frame: 324T
Sizing criteria: Max Power on Design Curve

30

100 267 mm

40

50

60

65
70

90
75
80

---- Design Curve ---62.8 m

Shutoff dP:

615 kPa

Min flow:

---

BEP:

75

70

Head - m

Shutoff head:

75% @ 194 m/hr

NOL power:
36.7 kW @ 296 m/hr

70

210 mm
60

65

30

-- Max Curve --

60

75.1

50 179 mm
40

40

50

60

65

Max power:
87.4 kW @ 380 m/hr

93 kW

18.7
70kW

75 kW
30
70

56 kW
45 kW
37 kW
30 kW

65
20

60
22 kW

NPSHr - m

10
15

50

100

150

50

100

150

200

250

300

350

200

250

300

350

10
5
0

m/hr
Curve efficiencies are typical. For guaranteed values, contact Aurora Pump or your local distributor. Las eficiencias en
curvas son tipicas. Para valores garantizados contacte a Aurora Pump o a su distribuidor local.
Performance Evaluation:
Flow
m/hr

Speed
rpm

Head
m

Efficiency
%

Power
kW

NPSHr
m

173

2950

50.7

74

32.1

3.56

144

2950

54.8

71

30.3

2.85

115

2950

58.3

64

28.3

2.31

86.4

2950

60.6

54

26

2.26

57.6

2950

62.1

41

23.5

2.26

H2Optimize 10.6.1.0

Selected from catalog: Aurora Pumps 50 Hz Vers: 4.2

MODELS
JU4H-NL14
JU4H-NL20
JU4H-NL22

FIRE PUMP ENGINES

JU4H-NL24
JU4H-NL34
JU4H-NL50

JU4H-NL52
JU4H-NLK4
JU4H-NL54

1275 mm

UK Purchased
1156 mm
T-Models
1029 mm
NA-Models

356 mm

NON-LISTED HEAT EXCHANGER COOLED ENGINES


GROSS POWER RATINGS KW/BHP
JU4H
MODEL

OVERALL WIDTH
740 mm

RATED SPEED
1760

1800

2000

2100

2200

2350

2400

45

60.5

59

79

NL22

59

NL24

59

NL14
NL20

49

66

50

67

53

71

73

54

75

56

NL34
NL50

90

121

92

123

102

137

107

143

142

106

NL52

2600

46

61

79

60

80

62

83

79

60

80

61.5

70

93.5

3000

77

58

78

58

78

82.5

66

88

68

91

68

91

70

93.5

85

114

94

126.5

94

126.5

109

146

109

146

109

146

119

159.5

119

159.5

119

159.5

70

93.5

104

140

104

140

104

140

104

140

100

134

103

138

114

153

NLK4
NL54

2960

57.5

48.5

65

2800

Power Rating: A 10% deduction in power must be made to determine the maximum allowable pump load

SPECIFICATIONS
ITEM

JU4H MODELS
NL14

NL20/22

NL24

Number of Cylinders
Aspiration

Compression Ratio

NL50/52

NLK4/54

4
NA

Rotation*
Weight kg (lb)

NL34

CW
413 (910)

424 (935)

17.6:1

17.0:1

Displacement l (cu. in.)

4.5 (275)

Engine Type

4 Stroke Cycle Inline Construction

Bore & Stroke mm (in.)

4.19 x 5.00 (106 x 127)

Installation Drawing

D525

Wiring Diagram AC

C07591

Wiring Diagram DC

C07575

Engine Series

John Deere 4045 Series

Abbreviations: CW Clockwise NA Naturally Aspirated T Turbocharged


*Rotation viewed from Heat Exchanger / Front of Engine

CERTIFIED POWER RATING

ENGINE RATINGS BASELINES

Each engine is factory tested to verify power and performance.

Engines are not to be used for continuous duty. Engines are to be used only for stationary
emergency standby fire pump service.

Although ratings are shown at specific speeds, Clarke engines can be applied at any
intermediate speed. To determine the intermediate speed power; make a linear
interpolation from the Clarke certified power curve. Contact Clarke or your Pump
OEM Representative to obtain details.

Engines are rated at standard SAE conditions of 29.61 in. (7521 mm) Hg barometer and
77F (25C) inlet air temperature [approximates 300 ft. (91.4 m) above sea level] by the
testing laboratory (see SAE Standard J 1349).
A deduction of 3 percent from engine horsepower rating at standard SAE conditions shall
be made for diesel engines for each 1000 ft. (305 m) altitude above 300 ft. (91.4 m)

A deduction of 1 percent from engine horsepower rating as corrected to standard SAE


conditions shall be made for diesel engines for every 10F (5.6C) above 77F (25C)
Page 1 ambient
of 8 temperature.

MODELS
JU4H-NL14
JU4H-NL20
JU4H-NL22

FIRE PUMP ENGINES

JU4H-NL24
JU4H-NL34
JU4H-NL50

JU4H-NL52
JU4H-NLK4
JU4H-NL54

ENGINE EQUIPMENT
EQUIPMENT

STANDARD

OPTIONAL

Air Cleaner

Direct Mounted, Washable, Indoor Service with Drip Shield

Disposable, Drip Proof, Indoor Service Outdoor Type

Alternator

12V-DC, 42 Amps with Belt Guard;


24V-DC, 40 Amps with Belt Guard

Exhaust Protection

Blankets on JU4H-NL14/20/22/24;
Metal Guards on Manifolds and Turbo on JU4H-NL34/50/52/K4/54

Coupling

Centaflex; Driveshaft

Exhaust Flex Connection

Stainless Steel Flex, Clamped Connection, 3 for NL14/20/22/24;


Stainless Steel Flex, Clamped Connection, 4 for NL34/50/52/K4/54

Flywheel Housing

SAE #3

Flywheel Power Take Off

11.5 SAE Industrial Flywheel Connection

Fuel Connections

Fire Resistant Flexible Supply and Return Lines

Fuel Filter

Primary Filter with Priming Pump

Fuel Injection System

Stanadyne Direct Injection

Engine Heater

240V-AC, 1500 Watt; 120V-AC, 1500 Watt

Governor, Speed

Constant Speed, Mechanical

Heat Exchanger

Tube and Shell Type, 14 BAR (206 PSI), BSP(F) Connections

Instrument Panel

English and Metric, Tachometer, Hourmeter, Water Temperature,


Oil Pressure and Two (2) Voltmeters

Junction Box

Integral with Instrument Panel; For DC Wiring Interconnection to


Engine Controller

Lube Oil Cooler

Engine Water Cooled, Plate Type

Lube Oil Filter

Full Flow with By-Pass Valve

Lube Oil Pump

Gear Driven, Gear Type

Manual Start Control

On Instrument Panel with Control Position Warning Light

Overspeed Control

Electronic with Reset and Test on Instrument Panel

Raw Water Solenoid Operation

Automatic from Engine Controller and from Engine Instrument


Panel

Run Stop Control

Manual Stop Lever

On Instrument Panel with Control Position Warning Light

Run Solenoid

12V-DC Energized to Stop

12V-DC Energized to Run; 24V-DC Energized to Run; 24V-DC


Energized to Stop

Silencer

Industrial with Clamped Connections

Starters

One (1) 12V-DC

Two (2) 12-V-DC; One (1) 24V-DC; Two (2) 24V-DC

Throttle Control

Adjustable Speed Control, Tamper Proof

Water Pump

Centrifugal Type, Dual Poly-Vee Belt Drive with Guard

Centrifugal Type, Single Poly-Vee Belt Drive with Guard

Abbreviations: DC Direct Current, AC Alternating Current, SAE Society of Automotive Engineers, BSP(F) British Standard Pipe Thread (Female)

UK, Ltd.
Grange Works, Lomond Rd., Coatbridge, ML5-2NN
United Kingdom
Tel +44-1236-429946
Fax +44-1236-427274
www.clarkefire.com
C133457 revA
14APR10

Fire Protection Products, Inc.


3133 E. Kemper Rd., Cincinnati, Ohio 45241
United States of America
Tel +1-513-475-FIRE (3473) Fax +1-513-771-0726
www.clarkefire.com

Specifications and information contained in this brochure subject to change without notice.

Page 2 of 8

FIRE PUMP MODEL: JU4H-NL14


Heat Exchanger
Naturally Aspirated
4.5L 4 Cylinder
65

60
58
57.5

55

50
48.5

45
45

40

35
1750

2000

2250

RESTRICTED:

2500
2750
ENGINE SPEED - RPM

3000

3250

USE ONLY FOR STAND-BY FIRE PUMP APPLICATIONS

ENGINE PERFORMANCE:
STANDARD CONDITIONS: (SAE J1349, ISO 3046)
77F (25C) AIR INLET TEMPERATURE
29.61 IN. (751.1MM) HG BAROMETRIC PRESSURE
#2 DIESEL FUEL (SEE C13940)

KEN WAULIGMAN 18SEP09

GROSS kW
Reduce published Gross kWs by 10% to determine
maximum pump load.
THIS DRAWING AND THE INFORMATION HEREIN ARE OUR
PROPERTY AND MAY BE USED BY
OTHER ONLY AS AUTHORIZED BY
US. UNPUBLISHED -- ALL RIGHTS
RESERVED UNDER THE
COPYRIGHT LAWS.

Page 3 of 8

CREATED

DATE CREATED

11/08/04

ENGINE MODEL JU4H-NL14


DRAWING NO.

C131979

REV

CLARKE
Fire Protection Products

JU4H-NL14
INSTALLATION & OPERATION DATA
UK Production
Basic Engine Description
Engine Manufacturer....John Deere Co.
Ignition Type.....................Compression (Diesel)
Number of Cylinders.............4
Bore and Stroke - mm (in.)......... 106 (4.19) x 127 (5.0)
Displacement - L(in.3)..........4.5 (275)
Compression Ratio.......... 17.0:1
Valves per cylinder - Intake...........1
Exhaust...........1
Combustion System..........Direct Injection
Rotary, 4 Stroke Cycle
Engine Type............
Naturally Aspirated
Aspiration.............
Firing Order (CW Rotation).........1-3-4-2
Rotation (Viewed from Front) - Clockwise....... Standard
Counter-Clockwise.....Not Available
Engine Crankcase Vent System........ Open
Installation Drawing......... D-545
Cooling System - 3 Pass
Engine H2O Heat - kW (Btu/sec)........
Engine Radiated Heat (With Blanket) - kW (Btu/sec)....
Engine Radiated Heat (Without Blanket) - kW (Btu/sec).
Heat Exchanger Minimium Flow
15C (60F) Raw H2O - L/min. (gal/min.)....
35C (95F) Raw H2O - L/min. (gal/min.)....

2350
32 (30)
6 (6)
13 (12)

2600
34 (32)
7 (7)
14 (13)

2800
36 (34)
8 (8)
17 (16)

3000
38 (36)
8 (8)
17 (16)

30 (8)

34 (9)

37 (10)

40 (11)

38 (10)

42 (11)

45 (12)

48 (13)

Heat Exchanger Maximum Cooling H2O


Max. Inlet Pressure - bar (lb./in.2)(kPa) 14 (203) (1400)
Flow - L/Min. (Gal./min.)........100 (26)
Thermostat, Start to Open - C (F)......86 (187)
Fully Opened - C (F)......91 (196)
14 (15)
Engine Coolant Capacity - L (qt.).........
2
Coolant Pressure Cap - kPa (lb./in. )......69 (10)
Maximum Engine H20 Temperature - C (F)...... 93 (200)
Minimum Engine H20 Temperature - C (F).....71 (160)
Electric System - DC
System Voltage (Nominal)........12
Battery Capacity for Ambients Above 0C (32F)
Voltage (Nominal)...........12
Qty. per Battery Bank.........1
SAE size per J537...........4D-640
CCA @ -18C (0F)........... 640
285
Reserve Capacity - Minutes........
Battery Cable Circuit*, Max Resistance - ohm.........0.0012
Battery Cable Minimum Size
0 -120 m Circuit* Length....... 00
121 - 160 m Circuit* Length.......... 000
161 - 200 m Circuit* Length.......... 0000
Charging Alternator Output - Amp.......40
Starter Cranking Amps - @ 15C (60F).......380
*Positive and Negative Cables Combined Length

24
24
2
4D-640
640
285
0.0012
00
000
0000
40
250

NOTE: This engine is Intendend For Indoor Installation Or In A Weatherproof Enclosure.


Page 4 of 8

(Continued)

CLARKE

Fire Protection Products

JU4H-NL14
INSTALLATION & OPERATION DATA (Continued)
UK Production
Exhaust System
2350
2600
2800
3000
3
3
Exhaust Flow - m /min. (ft. /min.)........ 13 (469)
15 (531)
16 (581)
18 (630)
Exhaust Temperature - C (F).......... 584 (1083) 568 (1055) 556 (1033) 543 (1010)
Maximum Allowable Back Pressure - kPa (in. H 20)... 7.5 (30)
Minimum Exhaust Pipe Dia. - mm (in.)**........ 76 (3)
Fuel System
Fuel Consumption - L/hr. (gal.hr.)....... 11.7 (3.1) 12.9 (3.4) 13.6 (3.6) 14.8 (3.9)
Fuel Return - L/hr. (gal./hr.)....... 34.1 (9.0) 36.0 (9.5) 37.5 (9.9) 39.0 (10.3)
Total Supply Fuel Flow - L/hr. (gal./hr.).......45.8 (12.1) 48.9 (12.9) 51.1 (13.5) 53.8 (14.2)
Fuel Pressure - kPa (lb./in. 2)......21-41 (3-6)
Minimum Line Size - Supply - (in.)...... .50 Schedule 40 Steel Pipe
Pipe Outer Diameter mm (in.).......... .033 (.848)
Minimum Line Size - Return - (in.)..... .375 Schedule 40 Steel Pipe
Pipe Outer Diameter mm (in.).......... .026 (.675)
Maximum Allowable Fuel Pump Suction
With Clean Filter - m H 20 (in. H 20)....... 0.8 (31)
Maximum Allowable Fuel Head above Fuel pump, Supply or Return - m (ft.).. 1.4 (4.5)
2
Fuel Filter Micron Size..........
Heater System
Jacket Water Heater
Wattage (Nominal)............
1500
Voltage - AC, 1P............ 115 (+5%, -10%)
Optional Voltage - AC, 1P......... 230 (+5%, -10%)

Induction Air System


Air Cleaner Type.....Indoors Service Only - Washable
Air Intake Restriction Maximum Limit
Dirty Air Cleaner - kPa (in. H 20)........... 2.5 (10)
Clean Air Cleaner - kPa (in. H20).........
3

1.2 (5)

Engine Air Flow - m /min. (ft. /min.)........ 4.7 (166)


Maximum Allowable Temperature (Air To Engine Inlet) - C (F)***. 54 (130)

5.3 (186)

5.7 (202)

6.2 (218)

Lubrication System
2
Oil Pressure - normal - kPa (lb./in. ).... 241-345 (35-50)
In Pan Oil Temperature - C (F)....... 104-118 (220-245)
Oil Pan Capacity - High - L (qt.)....... 7.5 (8)
Low - L (qt.) 6.5 (7)
Total Oil Capacity with Filter - L (qt.).. 8.5 (9)
Performance
2
BMEP - kPA (lb./in. )............ 462 (67)
448 (65)
437 (63)
426 (62)
Piston Speed - m/min. (ft./min.)......... 597 (1958) 661 (2167) 711 (2333) 762 (2500)
Mechanical Noise - dB(A) @ 1m..........
Consult Factory
Power Curve..............
C131088

** Based On Nominal System. Flow Analysis Must Be Done To Assure Adherance To System Limitations.
(Minimum Exhaust pipe Diameter is based on 15 feet of pipe, one elbow, and a silencer
pressure drop no greater than one half the max. allowable back pressure.)
*** Review For Power Deration If Air Entering Engine Exceeds 25C (77F)
C131253 revG
11FEB08 DSP

Page 5 of 8

CLARKE
Fire Protection Products

JU4H & JU6H ENGINE MODELS


ENGINE MATERIALS AND CONSTRUCTION
Air Cleaner
Type.... .. Indoor Usage Only
Oiled Fabric Pleats
Material..... Surgical Cotton
Aluminum Mesh
Air Cleaner - Optional
TypeCanister
MaterialPleated Paper
Housing..Enclosed
Camshaft
Material.. Cast Iron
Chill Hardened
Location..... In Block
Drive... Gear, Spur
Type of Cam..... Ground
Charge Air Cooler (JU6H-60,62,68,74,84, ADK0,
AD58, ADNG, ADN0, ADQ0, ADR0, AAQ8, AARG,
ADP8, ADP0, ADT0, AD88, ADR8, AD98, ADS0,
ADW8, ADX8, AD98 only)
Type.Raw Water Cooled
Materials (in contact with raw water)
Tubes 90/10 CU/NI
Headers 36500 Muntz
Covers
83600 Red Brass
Plumbing 316 Stainless Steel/ Brass
90/10 Silicone
Coolant Pump
Type.Centrifugal
DrivePoly Vee Belt
Coolant Thermostat
TypeNon Blocking
Qty1
Connecting Rod
TypeI-Beam Taper
MaterialForged Steel Alloy

Valves
Type.. Poppet
Arrangement Overhead Valve
Number/Cylinder 1 intake
1 exhaust
Operating MechanismMechanical Rocker Arm
Type of Lifter.. Large Head
Valve Seat InsertReplaceable
Fuel Pump
TypeDiaphragm
Drive Cam Lobe
Heat Exchanger (USA)
Type
Tube & Shell
Materials
Tube& HeadersCopper
ShellCopper
Electrode
Zinc

Heat Exchanger (UK)


Type
Tube & Bundle
Materials
Tube& HeadersCopper
Shell.
Aluminum

Injection Pump
Type. Rotary
Drive Gear
Lubrication Cooler
Type
Plate
Lubrication Pump
Type
Gear
Drive Gear

Crank Pin Bearings


TypePrecision Half Shell
Number1 Pair Per Cylinder
MaterialWear-Guard

Main Bearings
Type
Precision Half Shells
Material Steel Backed-Aluminum Lined

Crankshaft
MaterialForged Steel
Type of BalanceDynamic

Piston
Type and MaterialAluminum Alloy with Reinforced
Top Ring Groove
Cooling Oil Jet Spray

Cylinder Block
TypeOne Piece with
Non-Siamese Cylinders
MaterialAnnealed Gray Iron
Cylinder Head
Type.. Slab 2 Valve
Material. Annealed Gray Iron
Cylinder Liners
Type.. Centrifugal Cast, Wet Liner
Material...Alloy Iron Plateau, Honed
C13615 19 NOV 09 DSP

Piston Pin
Type
Full Floating - Offset

Piston Rings
Number/Piston3
TopKeystone Barrel Faced Plasma Coated
Second Tapered Cast Iron
Third
Double Rail Type
w/Expander Spring
Page 6 of 8

Page 7 of 8

VOLUME
(Liter)
100
200
250
300
500
750
1000
1250
1500
2000

(Inch) (mm)
1/2
250
1/2
250
1/2
250
1/2
250
1/2
250
1/2
250
1/2
300
1/2
300
1/2
350
1/2
350

(Inch) (mm)
1/2
480
1/2
500
1/2
560
1/2
560
1/2
750
1/2
870
1/2
1050
1
1150
1
1130
1
1180

(Inch) (mm)
1/2
60
1/2
60
1/2
60
1/2
60
1/2
60
1/2
60
1/2
60
1
60
1
60
1
60

(Inch) (mm)
1/2
3
1/2
3
1/2
3
1/2
3
1/2
3
1/2
3
1/2
3
1
3
1
3
1
4

DRY WEIGHT

(mm)
420
820
820
920
920
920
920
920
1130
1430

(mm)
620
1020
1020
1220
1220
1220
1220
1220
1530
1830

(mm)
580
600
660
660
850
970
1150
1250
1230
1280

(mm)
680
700
760
760
950
1070
1250
1350
1330
1380

(mm)
50
50
50
50
50
50
50
50
50
50

(mm)
480
500
560
560
750
870
1050
1150
1130
1180

(mm)
30
30
30
30

Approx. (kg)
45
70
80
90
120
140
170
200
220
260

'LHVHO)LUH3XPS&RQWUROOHU

3URGXFW'HVFULSWLRQ
7KH5RQDOG)LUH3XPS&RQWUROOHUIRUHQJLQH
GULYHQILUHSXPSVLVGHVLJQHGWRDXWRPDWLFDOO\VWDUWWKH
HQJLQHXSRQDGURSLQSUHVVXUHLQWKHZDWHUVXSSO\RU
IURPDQXPEHURIRWKHUGHPDQGVLJQDOV7KHFRQWUROOHU
SURYLGHVDXWRPDWLFF\FOHGFUDQNLQJDQGDODUP
SURWHFWLRQIRUYDULRXVHQJLQHIDLOXUHVZKHQUXQQLQJ
7KHHQJLQHPD\EHVWRSSHGDIWHUWKHGHPDQGSHULRGLV
WHUPLQDWHGHLWKHUPDQXDOO\RUDXWRPDWLFDOO\6HYHUDO
RSWLRQDOIHDWXUHVDUHDYDLODEOHZKLFKWKHORFDODXWKRULW\
KDYLQJMXULVGLFWLRQPD\UHTXLUH7KHVHRSWLRQVDUH
GHVFULEHGIXUWKHULQWKLVEXOOHWLQ

6WDQGDUG)HDWXUHV
6WDUWLQJ
7KHFRQWUROOHUZLOOVWDUWWKHHQJLQH
IURPDQ\RUDOORIWKHIROORZLQJ
GHPDQGVLJQDOV'URSLQZDWHUOLQH
SUHVVXUH7KHSUHVVXUHVZLWFKKDV
LQGHSHQGHQWO\DGMXVWDEOH 
36, KLJKDQGORZVHWSRLQWV+LJKHU
UDQJHDYDLODEOHVHH2SWLRQ/7KH
FRQWUROOHUZLOODOVRVWDUWWKHHQJLQH
IURPUHPRWHVWDUWVWDWLRQVGHOXJH
YDOXHVZLWFKHVGU\SLSHYDOYH
VZLWFKHVHWF

6HOHFWRU6ZLWFK3RVLWLRQV
7(67PRPHQWDULO\GURSVZDWHU
SUHVVXUHFORVLQJSUHVVXUHVZLWFK
VWDUWLQJHQJLQH
$872FRQWUROOHULQVWDQGE\PRGH
DOODXWRPDWLFIXQFWLRQVUHDG\IRU
RSHUDWLRQ
2))GLVFRQQHFWVDXWRPDWLFDQG
PDQXDOVWDUWIXQFWLRQV%DWWHU\
SRZHUVWLOODYDLODEOHWRFRQWUROOHU
0$18$/DOODXWRPDWLFIXQFWLRQVRI
WKHFRQWUROOHUDUHE\SDVVHGZKHQ
VWDUWHGZLWKWKHPDQXDOSXVKEXWWRQ
7ZRPDQXDOVWDUWSXVKEXWWRQVDUH
SURYLGHGIRUPDQXDOO\
FUDQNLQJWKHHQJLQHIURPHLWKHUVHW
RIEDWWHULHV%RWKVZLWFKHVPD\EH
GHSUHVVHGVLPXOWDQHRXVO\
LQFUHDVLQJEDWWHU\SRWHQWLDOWR
VWDUWHULQHYHQWRIDGYHUVHEDWWHU\
FRQGLWLRQ$OODODUPVDUHRSHUDWLYHLQ
WKHPDQXDOPRGH

0DQXDO6WRS3XVKEXWWRQ
0RXQWHGRXWVLGHRIFRQWUROOHU
%\SDVVHVVHOHFWRUVZLWFKDOORZLQJ
HQJLQHVKXWGRZQDIWHUVWDUWLQJ
GHPDQGVKDYHUHWXUQHGWR
QRUPDO&RQWUROOHULVDXWRPDWLFDOO\
UHVHWIRUVWDQGE\PRGH

)DLOXUH$ODUPVRQ&RQWUROOHU
&LUFXLWVDUHVXSSOLHGWRSURYLGHORFDO
OLJKWVDQGDODUPIRUWKHIROORZLQJ  
)DLOXUHWR6WDUW RYHUFUDQN   /RZ
2LO3UHVVXUH  +LJK
:DWHU7HPSHUDWXUH  2YHUVSHHG
DODUPDQGVKXWGRZQ   /RVVRI
%DWWHU\&KDUJHU2XWSXW7KLVODVW
DODUPDOVRSURYLGHVDPHDQVRI
PRQLWRULQJORVVRI$&SRZHU 
9$& /RVVRI9$&UHVXOWVLQ
ORVVRIFKDUJHURXWSXWDQGPLVVLQJ
EDWWHU\GHWHFWLRQ

6WDWXV/LJKWV
7KUHHJUHHQOLJKWVDUHSURYLGHGRQ
WKHFRQWUROOHULQGLFDWLQJEDWWHU\
SRZHULVDYDLODEOH
IURP%DWWHU\DQG%DWWHU\7KH
WKLUGODPSLQGLFDWHVWKDWWKHFRQWURO
VZLWFKLVLQ$XWRSRVLWLRQ

&RQWURO5HOD\V
5HOD\VDUHGXVWWLJKWSOXJLQIRU
HDVHRIVHUYLFLQJIURPIURQWRI
FDELQHW

qwertyuiopasdfghjklzxcvbnmqwertyui
opasdfghjklzxcvbnmqwertyuiopasdfgh
jklzxcvbnmqwertyuiopasdfghjklzxcvb
JOCKEY PUMP
nmqwertyuiopasdfghjklzxcvbnmqwer
SparePartListBook
ControllerModel:GPD
AURORA VERTICAL MULTISTAGE IN-LINE
tyuiopasdfghjklzxcvbnmqwertyuiopas
Model : PVM 5-13
dfghjklzxcvbnmqwertyuiopasdfghjklzx
cvbnmqwertyuiopasdfghjklzxcvbnmq
wertyuiopasdfghjklzxcvbnmqwertyuio
pasdfghjklzxcvbnmqwertyuiopasdfghj
klzxcvbnmqwertyuiopasdfghjklzxcvbn
mqwertyuiopasdfghjklzxcvbnmqwerty
uiopasdfghjklzxcvbnmqwertyuiopasdf
ghjklzxcvbnmqwertyuiopasdfghjklzxc
vbnmqwertyuiopasdfghjklzxcvbnmrty
uiopasdfghjklzxcvbnmqwertyuiopasdf
ghjklzxcvbnmqwertyuiopasdfghjklzxc

PERTAMINABALIKPAPANDEPOTPANGKALANBUN,
DEPOTPULANGPISAU,DPPUJUWATA
PLN

Preparedby:PT.RodaNurmala

PVM/PVMI
PVMX
50Hz
FLOW MANAGEMENT SOLUTIONS

VERTICAL MULTISTAGE CENTRIFUGAL IN-LINE


LINE PUMPS

A LEADER
IN WATER TECHNOLOGY
Pentair is one of the worlds leading
companies in the planning and
manufacture of innovative products
and systems suitable in any situation
requiring the treatment, transportation
and storage of water. The activity
and success of Pentair is based on
values such as constant improvement,
the continuous development of
new products, high-performance,
competence, business ethics and
market leadership. Pentairs employees
share personal values such as
accountability, deep respect for people
and the environment and a candid and
practical work style. Strong customer
relationships and high quality standards
allow Pentair to rank amongst the
leading producers of technology and
instruments for water treatment.

FLOW TECHNOLOGIES

FILTRATION

Vertical and horizontal centrifugal


pumps; submersible pumps for
domestic, commercial, agricultural and
industrial use; pumps for the drainage of
clear and wastewaters; pressure booster
units and fire-fighting systems.

Industrial, residential and commercial


filtration systems; filter cartridges,
components for the filtration of drinking
water, pumps for mobile homes and
boats and pumps and accessories for
applications in industry and the catering
service.

SAFE, CLEAN WATER

Providing clean, safe water to an


ever-growing portion of the population
is the Mission of Pentair: a valid
organization is engaged to serve our
customers in an efficient manner
through production plants located
in every corner of the world and
specialized sales and marketing
networks.
WATER TREATMENT

POOL AND SPA

Residential, commercial and industrial


water conditioning control valves; fibreglass wound expansion tanks and vessels;
water storage tanks.

A complete range of pool/spa equipment


and accessories: filters, pumps, heating
and lighting systems and cleaning
accessories; dosing and control systems
and products and accessories for
fountains and ponds.

PVM/PVMI/PVMX
VERTICAL MULTISTAGE CENTRIFUGAL PUMPS
HIGH HYDRAULIC EFFICIENCY, MOTOR DESIGNED TO EN STANDARDS

The PVM, PVMI and PVMX are non-self


priming vertical multistage pump of
in-line design, flange or with Victaulic
coupling with equally sized suction and
discharge ports.
Stage construction with stainless steel
impellers, chambers and pressure
casing. Pump stub shaft and motor
shaft of the IEC-standards motor are
directly close coupled.

All pumps are equipped with a


cartridge type mechanical seal for easy
maintenance.
PVM, PVMI and PVMX pumps have
different pump sizes and various
numbers of stages to provide the flow
and the pressure required.

APPLICATIONS

Water supply

High pressure washes

Pressure boosting systems

Liquid transfer

Water treatment/filtration

Firefighting systems

Irrigation

Boiler feed

PVM/PVMI/PVMX
VERTICAL MULTISTAGE CENTRIFUGAL PUMPS
MOTOR

Asynchronous electric motor


with enclosed stator and external
ventilation
Main dimensions are in accordance
with DIN and IEC standards
Class F insulation
Level of protecion IP55
Maximum environmental temperature
50C
Speed of rotation 2900 rpm

MOTOR TYPE -2 POLES


[HP]

[KW]

0.5

Flange

NOMINAL CURRENT IN [A]


Frame

3~230V

3~400V

0.37

71

1.9

1.1

0.75

0.55

71

2.7

1.6

0.75

80

3.5

2.1

1.5

1.1

90S

5.2

3.0

1.5

90L

6.1

3.6

2.2

90L

9.8

5.7

100L

12.3

7.1

5.5

112M

15.0

8.7

3~400V

3~690V

B14

7.5

5.5

132S

12.1

6.9

10

7.5

132S

15.7

8.8
3~400V

15

11

20

15

25

18.5

30

160M
160M

27.2

160L

33.25

22

180M

39.4

40

30

200L

53.35

50

37

200L

65.4

60

45

225M

82.9

75

55

250M

96.75

100

75

280S

128.5

B5

* The Nominal Current values indicated refer to a standard motor configuration.


For detailed information, please contact your countrys Pentair office

20.1

PVM/PVMI/PVMX
VERTICAL MULTISTAGE CENTRIFUGAL PUMPS
PRODUCT DATA
50Hz

Nominal Flow (m3/h)

PVM, PVMI, PVMX

10

15

20

Flow Range (m3/h)

0.7-2.4

1.2-4.5

2.5-8.5

5-13

8.5-23.5

10.5-29

Max. Pressure (bar)

21,5

23

24

21.5

23

24.3

Fluid Temperature
Motor Power (kW)

-15C to + 120C
0.37-2.2

0.37-3

0.37-5.5

0.37-7.5

1.1-15

1.1-18.5

PVM: Cast iron and stainless steel EN 1.4301/AISI 304

PVMI: Stainless steel EN 1.4301/AISI 304

PVMX: Stainless steel EN 1.4401/AISI 316

DN 50

DN 50

Version

Motor

Main connection 1~ (V/Hz) Permissible voltage tolerance 10%

220-240 V 50 Hz

Main connection 3~ (V/Hz) Permissible voltage tolerance 10%

0.37-7.5 kW 220-240/380-415 V 50 Hz
from 11 kW 380-415 V 50 Hz

Insulation class

Enclosure class

IP 55

Ambient temperature

50C

PVM Pipe Connection

Flange

DN 25/DN 32

DN 25/DN 32

DN 25/DN 32

DN 40

DN 25/DN 32

DN 25/DN 32

DN 25/DN 32

DN 40

DN 50

DN 50

R DN32

R DN32

R DN32

R2 DN50

R2 DN50

R2 DN50

PVMI/PVMX Pipe Connection

Flange
Victaulic connection
Mechanical Seals

SiC/SiC

Standard

Seals

EPDM
Viton

Standard

PVM/PVMI/PVMX
VERTICAL MULTISTAGE CENTRIFUGAL PUMPS
PUMP CONSTRUCTION
POS.

NAME

MATERIAL

PVM 1, 3, 5, 10, 15, 20

PVMI 1, 3, 5, 10, 15, 20

PVMX 1, 3, 5, 10, 15, 20

36

Pump head

Cast Iron

EN-GJL-200 ; ASTM 25B

EN-GJS-450-10 ; ASTM 65-45-12

EN-GJS-450-10 ; ASTM 65-45-12

56

Pump head cover

Stainless Steel

N/A

1.4301 ; AISI 304

1.4401 ; AISI 316

18

Impeller

Stainless Steel

1.4301 ; AISI 304

1.4301 ; AISI 304

1.4401 ; AISI 316

37

Shaft

Stainless Steel

1.4057 ; AISI 431

1.4057 ; AISI 431

1.4401 ; AISI 316

48

Outer sleeve

Stainless Steel

1.4301 ; AISI 304

1.4301 ; AISI 304

1.4401 ; AISI 316

82

O-Ring for outer sleeve

EPDM

12

Chamber

Stainless Steel

1.4301 ; AISI 304

1.4301 ; AISI 304

1.4401 ; AISI 316

24

Neck Ring

PTFE

Cast Iron

EN-GJL-200 ; ASTM 25B

N/A

N/A

Stainless Steel

N/A

1.4301 ; AISI 304

1.4401 ; AISI 316

59

Base

62

Base plate

Cast Iron

N/A

EN-GJL-200 ; ASTM 25B

EN-GJL-200 ; ASTM 25B

44

Coupling

Fe-Cu-C

SINT C11 ; MPIF FC0525

SINT C11 ; MPIF FC0525

SINT C11 ; MPIF FC0525

57

Mechanical seal

Cartridge type

PVM/PVMI/PVMX 5
VERTICAL MULTISTAGE CENTRIFUGAL PUMPS
HYDRAULIC PERFORMANCE

Duty Point

15

PVM/PVMI/PVMX 5
VERTICAL MULTISTAGE CENTRIFUGAL PUMPS
PUMP DIMENSIONS
PVM

PVMI - PVMX

MOTOR

Net
Weight
[kg]

DIMENSION [mm]

PUMP
TYPE

DIN Flange

P2
[HP]

[KW]

H1

D1

D2

D3

H2

DIN
Flange

DIMENSION [mm]

Victaulic
H1

H2

DIN Flange
H1

D1

Net Weight [kg]

D2

D3

Victaulic

H2

DIN
Flange

PVM 5-2

0,5

0,37

279

474

141

115

23,3

257

452

282

477

141

115

19,2

20,1

PVM 5-3

0,75

0,55

306

501

141

115

24,2

284

479

309

504

141

115

20,3

21,2

PVM 5-4

0,75

0,55

333

528

141

115

24,8

311

506

336

531

141

115

20,8

21,8

PVM 5-5

1,0

0,75

366

601

141

115

27,4

344

579

369

604

141

115

23,4

24,3

PVM 5-6

1,5

1,1

393

628

141

115

29,1

371

606

396

631

141

115

25,1

26,0

PVM 5-7

1,5

1,1

420

655

141

115

29,6

398

633

423

658

141

115

25,6

26,5

PVM 5-8

1,5

1,1

447

682

141

115

30,1

425

660

450

685

141

115

26,1

27,1

PVM 5-9

2,0

1,5

490

781

177

141

39,3

468

759

493

784

177

141

35,4

36,4

PVM 5-10

2,0

1,5

517

808

177

141

39,9

495

786

520

811

177

141

36,0

36,9

PVM 5-11

3,0

2,2

544

835

177

141

43,2

522

813

547

838

177

141

39,3

40,3

PVM 5-12

3,0

2,2

571

862

177

141

43,7

549

840

574

865

177

141

39,9

40,8

PVM 5-13

3,0

2,2

598

889

177

141

44,2

576

867

601

892

177

141

40,4

41,4

PVM 5-14

3,0

2,2

625

916

177

141

44,8

603

894

628

919

177

141

41,0

41,9

PVM 5-15

3,0

2,2

652

943

177

141

45,2

630

921

655

946

177

141

41,5

42,5

PVM 5-16

3,0

2,2

679

970

177

141

45,8

657

948

682

973

177

141

42,1

43,0

PVM 5-18

4,0

3,0

737

1053

197

147

54,3

715

1031

740

1056

197

147

50,3

51,3

PVM 5-20

4,0

3,0

791

1107

197

147

55,5

769

1085

794

1110

197

147

51,6

52,5

PVM 5-22

5,5

4,0

845

1171

220

161

59,8

823

1149

848

1174

220

161

55,8

56,8

PVM 5-24

5,5

4,0

899

1225

220

161

60,8

877

1203

902

1228

220

161

56,9

57,8

PVM 5-26

5,5

4,0

953

1279

220

161

62,7

931

1257

956

1282

220

161

58,0

58,9

PVM 5-29

5,5

4,0

1034

1360

220

161

64,6

1012

1338

1037

1363

220

161

59,7

60,6

PVM 5-32

7,5

5,5

1145

1507

235

197

300

90,1

1123

1485

1148

1510

235

197

300

84,9

85,8

PVM 5-36

7,5

5,5

1253

1615

235

197

300

92,6

1231

1593

1256

1618

235

197

300

87,1

88,1

14

WATER ENERGY
WE PUT ENERGY INTO YOUR WATER
Pentair has been committed to the
design and production of electric
water pumps providing our customers
with quality products and concrete
solutions for all their needs. Within
the wide Pentair Water Supply range,
engineering firms and plumbing and
heating/cooling distributing centres
can find products and systems which
meet any need with regards to water
supply and pressurization in the realm
of residential and commercial building,
irrigation and industry applications.

FIRE-FIGHTING SYSTEMS AND


PRESSURIZATION SYSTEMS

ELECTRIC PUMPS FOR RESIDENTIAL


USE

Vertical and horizontal centrifugal


pumps. Complete systems for the
transfer and pressurization of water.
Fire-fighting systems.

Submersible pumps, self-priming


pumps, multistage centrifugal
pumps and compacting pumping
systems for domestic water supply,
irrigation and the re-utilization of
harvested rainwater.

ELECTRIC PUMPS FOR DRAINAGE

ELECTRIC PUMPS FOR OPEN AND


DRILLED WELLS

Pumps for the transfer of clear,


dirty and wastewaters and sewage.
Pumps for numerous applications
(water in basins, tanks, pumping
stations etc.)

34

Submersible pumps for irrigation


and pumping underground waters.

Avenue de Sevelin, 18 1004 LAUSANNE - SWITZERLAND

WWW.PENTAIR.COM

All Pentair trademarks and logos are owned by Pentair, inc. All other brand or product names are trademarks or registered marks of their respective owners.
Because we are continously improving our products and serviceds, Pentair reserves the right to change specifications without prior notice.
Pentair is an equal opportunity employer.
01/2014 2014 Pentair, Inc. All Rights Reserved.

-RFNH\)LUH3XPS&RQWUROOHU
3URGXFW'HVFULSWLRQ
$&52667+(/,1(
-2&.(<3803&21752//(56
7KH)'-3MRFNH\SXPSFRQWUROOHUVRSHUDWH
DFURVVWKHOLQH)XOOYROWDJHLVDSSOLHGWRWKH
PRWRUIRUVWDUWLQJE\WKHXVHRIDVLQJOHPRWRU
VWDUWHU6WDUWLQJLQUXVKFXUUHQWLVDSSUR[LPDWHO\
RIUDWHGIXOOORDGDPSHUHV

:<('(/7$ 6WDU'HOWD 
-2&.(<3803&21752//(56
:KHQVL[RUWZHOYHOHDGGHOWDFRQQHFWHG
MRFNH\SXPSPRWRUVDUHVWDUWHGZ\H VWDU 
FRQQHFWHGDSSUR[LPDWHO\RIOLQHYROWDJH
LVDSSOLHGWRHDFKZLQGLQJ7KHPRWRUGHYHORSV
RIIXOOYROWDJHVWDUWLQJWRUTXHDQGGUDZV
RIQRUPDOORFNHGURWRUFXUUHQWIURPWKH
OLQH$IWHUDVHFRQGWLPHGHOD\ GXULQJZKLFK
WKHPRWRUDFFHOHUDWHV LWLVUHFRQQHFWHGIRU
QRUPDORSHUDWLRQ

You might also like