Professional Documents
Culture Documents
Note:
Pneumatic 36
General
This Document must not be used to perform work on aircrafts. The official manuals for these aircrafts shall be used !
FROM ENG 1
HP STAGE
LEGENDE:
R S
SET
Q
0 0 LAST
FF
RESET
GND
CONNECTION
0 1
1 0
1 1
HYDRAULIC TANK
PRESSURIZATION
WATER TANK
PRESSURIZATION
PACK 1
PACK 2
LH WING
ANTI - ICE
RH WING
ANTI - ICE
CONTROL
TEMPERATURE
SENSOR
6HA1
CTS
HP GROUND
CONNECTION
TO BMC2
PRECOOLER
7150HM1
TO BMC 1
FAN AIR
VALVE
9HA1
7HA1
ENG
START
SYS.
FUEL
PRESS
PUSH
REGULATED
PRESSURE
TRANSDUCER
TO BMC 1
IGV
ACT
ENG 1 FIRE
TEMPERATURE INDICATION
AND MONITORING
PT
PR
TO BMC 2
OPV
EXHAUST
AIR INLET
TRANSFERRED
PRESSURE
TRANSDUCER
TPT
MPM: 36-20-01
ENG BLEED
FAULT LIGHT
INOP - BMC TEST
FAILURE MONITORING
VIA CFDS
PRESSURE INDICATION
AND MONITORING
ENG 1
IDENT.
(BMC 1
ONLY)
STARTER
VALVE (S)
OPEN
RPT
APU BLEED
LH ONLY
MPM: 36-11-02
CLOSURE PROCEDURE
PRV (REG 44 PSI)
APU BLEED
LH AND RH
REG
BLEED
PRESSURE
REGULATOR
VALVE
4001HA1
FROM
ENG2
OPEN
C
O
M
P
APU
FAV
VLV POS
FUEL PRESS
POS.
LVDT
OVER
BOARD
OVER
PRESSURE
VALVE
5HA1
FULL CLOSE
APU BLEED
(CONTROL)
VALVE
TLT
VLV POS
M2
MAN
BLEED PRESSURE
REGULATED VALVE
CONTROL SOLENOID
10HA1
CLOSE PRV AND HPV
TCT
T0 200 C
M1
AUTO
PT < 4 PSI
AND ENG STOP
PRV CLOSE
VLV POS
HIGH PRESSURE
BLEED VALVE
4000HA1
AT 8PSI
HP PRESS
MPM: 36-11-07
HPBV CLOSURE
PROCEDURE
- CLOSE AT HP
PRESS > 100PSI
- CLOSE AT
REG
PRESS
VLV POS
TO BMC 1+2
DOWNSTREAM
HPV
IP > 36PSI
IP
CHECK
VALVE
7110HM1
- CLOSE IF
PRV CLOSED
F
A
N
SET
RESET
450-2
- STARTS OPEN
FF
Q FF
QRG FIGURE
HPV:
SET
TO BMC 1+2
SEE ALSO
OVERTEMP
257 C
OVERPRESS 57 PSI
th
(REG 36 PSI)
TO HYDRAULIC
RESERVOIR
(ENG 1 ONLY)
IP
STAGE
A319
ONLY
SERVO PRESS.
LH WING LEAK
LH PYLON LEAK
WAI SELECTED "ON"
NORMAL CRUISE BLEED CONFIG
PS3 > 80PSIG & FLT ALT > 15000FT
AC IDENT (A319 only)
HP VALVE
CLOSED
SOL HP BLEED
OVERRIDE
ENG 1 11HA1
(ENG 2 11HA2)
10s
TD
X-BLEED
PACK 2
FOR ENGINE
NACELLE ANTIICE VALVE
HP
th
9 STAGE
ENG 1 BLEED
APU BLEED
FAULT
FAULT
OFF
ON
SHUT
AUTO
ENG 2 BLEED
OPEN
FAULT
OFF
IF BLEED PRESS
12-60 PSI
USED FOR:
ZTC 8HK 93VU121
_ ENG MAX N1-LIMIT CALC
21-63
_ WING ANTI-ICE SYST MONG
Issue 3
SR Technics
A
Note:
Pneumatic 36
General
This Document must not be used to perform work on aircrafts. The official manuals for these aircrafts shall be used !
HYDRAULIC TANK
PRESSURIZATION
WATER TANK
PRESSURIZATION
X - FEED VALVE
6HV 192
PACK 1
PACK 2
RH WING
ANTI - ICE
LH WING
ANTI - ICE
MAN
LH PYLON
LOOP
M2
FROM
ENG 1
ON
SHUT
FROM
ENG 2
VLV. POS.
TO BMC 1
AND BMC 2
AUTO
FAULT
RH PYLON
LOOP
OPEN
HP GROUND
CONNECTION
X - BLEED
M1 AUTO
OPEN
ON
APU BLEED
CONTROL
VALVE (P33)
AUTO
LH WING
RH WING
RH PYLON
LOOP B
LOOP B
LOOP
TM
ACT
BMC 2
1HA2
96VU122
LH WING LEAK
LH PYLON LEAK
RH WING LEAK
RH PYLON LEAK
APU LEAK
POSITION
LVDT
BLEED FLOW
XDCR (P24)
LCDT
SENSOR
(P29)
C
O
M
P
APU
10s TD
FUEL PRESS
EXHAUST
FUEL
PRESS
IGV
ACT
LH WING OR LH PYLON
OR APU LEAK WARN
(INHIBITED DURING MES)
RESET
SET
LEAK WARN
FF
DRIVER
ARINC 429
X-TALK BUS
LH WING LEAK
LH PYLON LEAK
RH WING LEAK
RH PYLON LEAK
APU LEAK
SURGE PROTECTION
BLEED CONTROL
APU BLEED
VALVE CLOSE
RESET
APU
TO BMC 2
LCD TEMP
(LCDT SENSOR P29)
TM (P21)
DRIVER
S
(BLEED FLOW
XDCR P24)
N
% RPM
(SENSOR P22)
INLET
TEMP/PRESS
MAX. EGT
LIMITATION
EGT
MASTER SW
FAULT
NOT OPERATIVE
SET
LEAK WARN
FF
APU ECB
59 KD
BLEED
ON CMD
S
+
BMC 1
1HA1
95VU121
LH WING OR LH PYLON
OR APU LEAK WARN
(INHIBITED DURING MES)
INLET
TEMP/PRESS
SENSOR (P22)
AIR INLET
POSITION
LVDT
LH WING
RH WING
LH PYLON
LOOP A
LOOP A
LOOP
ON
APU LOOP
ZONE TEMPERATURE
CONTROLLER
ECS DEMAND
EIU 1
MES DEMAND
EIU 2
Issue 3
SR Technics