Professional Documents
Culture Documents
ACP/AMU
AEVC
CIDS
CMC
CPC
DMC
EIVMU
FCDC
FCMC
FCU
FM
FMGEC
FWC
LGCIU
Pack Control
PHC
PSCU
SDAC
SDCU
WHC
AEVC (2HQ)
CIDS Director (101 RH)
CMC 1 (1 TM 1 )
CPC1 (311 HL)
DMC1 (1WT1) DMC3 (1WT3)
EIVMU1 (1 KS1)
FCDC1 (1 CE1)
FCMC1 (5QM1)
FCU1 (3CA1)
FMGEC
FMGEC 1 (1CA1)
FWC1 (1WW1)
LGCIU1 (5GA1)
PC1 (531 HH)
PHC1 (6DA1) PHC3 (6DA3)
PSCU1 (5MJ1)
SDAC1 (1WV1)
SDCU1 (20WH2)
WHC1 (2DG1)
ACP/AMU
CIDS
CMC
CMC2 (1TM2)
CPC
CPC2 (312HL)
DMC
DMC2 (1WT2)
EIVMU
EIVMU (1 KS2)
FCDC
FCDC2 (1 CE2)
FCMC
FCMC2 (SOM2)
FCU
FM
FCU2 (3CA2)
FMGEC
FMGEC
FMGEC 2 (1CA2)
FWC
FWC2 (1 WW2)
LGCIU
LGCIU2 (SGA2)
Pack Control
Pack Controller
PC2 (S32HH)
PHC
PHC2 (6DA2)
PSCU
PSCU2 (SMJ2)
SDAC
SDAC2 (1WV2)
SDCU
SDCU2 (20WH2)
Vent Control
WHC
Zone Control
Ventilation Controller
Window Heat Computer
Zone Controller
VC (280HN)
WHC2 (2DG2)
ZC (630HK)
CAB PR
A330
NO GO
NO GO
MEL 21-31-04
MEL 21-31-01
MEL 21-31-01
MEL 21-31-01
COND A330
COMD AFT CRG ISOL FAULT
-Reset breaker VENT CANT Lane 1/2 on RH reset panel
COND AFT CRG VENT FAULT
-Reset breaker VENT CANT Lane 1/2 on RH reset panel
COND BULK CRG DUCT OVHT
-Reset breaker VENT CANT Lane 1/2 on RH reset panel
MEL 21-28-03-B
MEL 21-43-02
MEL 21-28-04-8
MEL 21-28-03-A
MEL 21-43-02
RH reset panel
MEL 21 28-04-A
RH reset panel
MEL 21-21-01
RH reset panel
MEL 21-21-01
RH reset panel
MEL21-23-01
RH reset panel
MEL21-21-01
RH reset panel
MEL 21-26-04
RH reset panel
MEL 21-63-01
panel
MEL 21-63-01
MEL 21-63-01
VENT A330
MEL 21-21-01 or MEL 2126-08-A
MEL 21-26-01
MEL 21-27
MEL 21-26-02
MEL 21-25
AIR A330
AIR ABNORM BLEED CONFIG
-Operational message...No further action required.
AIR APU BLEED FAULT
-Perform Bite Test of BMC 1 and 2 on MCDU (ATA 36)
AIR APU BLEED LEAK
-Perform Bite Test of BMC 1 and 2 on MCDU (ATA 36)
AIR BLEED LO TEMP
-Perform Bite Test of BMC 1 and 2 on MCDU (ATA 36)
AIR BMC 1 + 2 FAULT
-Perform Bite Test of BMC 1 and 2 on MCDU (ATA 36)
AIR BMC 1 FAULT
-Perform Bite Test of BMC 1 on MCDU (AT A 36)
AIR BMC 2 FAULT
-Perform Bite Test of BMC 2 on MCDU (ATA 36)
AIR ENG 1 BLEED FAULT
-Perform Bite Test of BMC 1 on MCDU (AT A 36)
AIR ENG 1 BLEED LEAK
-Perform Bite Test of BMC 1 on MCDU (ATA 36)
AIR ENG 1 BLEED NOT CLSD
-Perform Bite Test of BMC 1 on MCDU (ATA 36)
AIR ENG 1 HPV NOT OPEN
-Perform Bite Test of BMC 1 on MCDU (ATA 36)
AIR ENG 2 BLEED FAULT
-Perform Bite Test of BMC 2 on MCDU (ATA 36)
AIR ENG 2 BLEED LEAK
-Perform Bite Test of BMC 2 on MCDU (ATA 36)
AIR ENG 2 BLEED NOT CLSD
-Perform Bite Test of BMC 2 on MCDU (ATA 36)
AIR ENG 2 HPV NOT OPEN
-Perform Bite Test of BMC 2 on MCDU (ATA 36)
AIR HOT AIR SYS 1 FAULT
-Reset breaker ZONE CONT on RH reset panel
MEL 36-11-01
MEL 36-12-02
MEL 36-12-01
MEL 36-11-01
MEL 36-11-01
MEL36-11-01
MEL36-11-01
MEL 36-11-01
NO GO
MEL 36-11-02
MEL 36-11-07
MEL 36-11-01
NO GO
MEL 36-11-02
MEL 36-11-07
MEL 21-63-03
NO GO
COM A330
COM ACARS 1 FAULT
MEL 23-24-01
- Perform Bite test of ACARS on MCDU (COM-Radio)
COM ACARS ALERT
Not applicable
-If no message on PFRNO ACTION
COM ACARS CALL
Not applicable
- If no message on PFRNO ACTION
COM CIDS 1 + 2 FAULT
MEL 23-73-01
-Reset breakers CIDS1, CIDS2 and DMC3 on reset panels RH and LH
COM CIDS PA FAULT
MEL 23-31-01
-Perform Interface and Power Up test as follow:
-Open CBs CIDS DIR2 and DIR1 ESS on panel 742VU
-Open CBs CIDS DIR2 and DIR1 NORM on panel 722VU
-Close all breakers again
COM HF 1 EMMITTING
- Reset breaker 2RE1 on panel 721VU
COM HF 2 EMMITTING
- Reset breaker 2RE2 on panel 722VU
COM VHF 1 EMMITTING
- Reset breaker 2RC1 on breaker panel 742VU
COM VHF 2 EMMITTING
- Reset breaker 2RC2 on breaker panel 722VU
COM_VFH3 EMMMITTING
NO GO
NO GO
NO GO
NO GO
NO GO
ELEC A330
ELEC AC BUS 1 FAULT
-Perform Bite test of the ECMU1 on MCDU (AC page)
ELEC AC BUS 2 FAULT
- Perform Bite test of the ECMU2 on MCDU (AC page)
NO GO
NO GO
NO GO
CB 17XH on panel 742VU
CB 12XH on panel 7 42VU
NO GO
CB 8XH on panel 742VU
CB 15XH on panel 742VU
CB 17XH on panel 742VU
MEL 24-22-02
MEL 24-22-01
MEL 24-22-01
NO GO
- Perform Bite Test of the APU Fire and Overheat Detection Unit
ATA 26 Fire Prot: ENG/APU FDU APU Test
SMOKE A330
SMOKE AFT CRG BTL 1 FAULT
MEL 26-23-01
- Reset breakers SDCU 1 and 2 on LH and RH reset panels
SMOKE AFT CRG BTL 2 FAULT
MEL 26-23-01
- Reset breakers SDCU 1 and 2 on LH and RH reset panels
SMOKE AFT CRG DET FAULT
MEL 26-16-02
- Reset breakers SDCU 1 and 2 on LH and RH reset panels
SMOKE AFT/BULK CRG SMOKE
NO GO
- Reset breakers SDCU 1 and 2 on LH and RH reset panels
- If no real smoke in bulk.. .or oil in the Air cond system,
Perform Bite Test of Smoke Detection System with MCDU
(AT A 26-SMOKE- TEST)
SMOKE AVIONICS DET FAULTNO GO
- Reset breakers SDCU 1 and 2 on LH and RH reset panels
SMOKE AVNCS VENT SMOKE
NO GO
- Reset breakers SDCU 1 and 2 on LH and RH reset panels
- If no real smoke in avionicsor oil in the Air cond system,
Perform Bite Test of Smoke Detection System with MCDU
(AT A 26-SMOKE- TEST)
SMOKE BULK CRG DET FAULT
MEL 26-16-03
- Reset breakers SDCU 1 and 2 on LH and RH reset panels
SMOKE CAB REST DET FAULT
MEL 26-18-02
- Reset breakers SDCU 1 and 2 on LH and RH reset panels
SMOKE DETFAULT
NO GO
- Reset breakers CIDS 1 and 2 on LH and RH reset panels
- Reset breakers SDCU 1 and 2 on LH and RH reset panels
SMOKE FLT REST DET FAULT
- Reset breakers SDCU
SMOKE FWD CRG BTL 1 FAULT
- Reset breakers SDCU
SMOKE FWD CRG BTL 2 FAULT
- Reset breakers SDCU
SMOKE FWD CRG DET FAULT
- Reset breakers SDCU
MEL
1 and 2 on LH and RH reset panels
MEL
1 and 2 on LH and RH reset panels
MEL
1 and 2 on LH and RH reset panels
MEL
1 and 2 on LH and RH reset panels
26-18-01
26-23-01
26-23-01
26-16-01
10
F/CTL A330
F/CTL ADR DISAGREE
NO GO
- Check Post Flight Report
F/CTL AIL SERVO FAULT
MEL 27-14-01
-Recycle FCPC 2 (Flight Control Primary Computer)
F/CTL ALTN LAW
NO GO
-Recycle FCPC 1 & 2 (Flight Control Primary Computer)
-Recycle FCSC 1 & 2 (Flight Control Secondary Computer)
F/CTL ECVT LAW
NO GO
-Check Post Flight Report
F/CTL ELEV REDUND LOST
NO GO
-Perform Bite Test of the EFCS ground scanning with MCDU
(AT A 27 F/CTL EFCS EFCS1 GND SCANNING)
F/CTL ELEV SERVO FAULT
MEL 27-34-01
-Perform Bite Test of the EFCS ground scanning with MCDU
(AT A 27 F/CTL EFCS EFCS1 GND SCANNING)
F/CTL FCFC 1 FAULT
MEL 27-95-01
-Reset breaker FCDC 1 on LH reset panel
F/CTL FCDC 1+2 FAULT
MEL 27-95-01
-Reset breaker FCDC 1 and 2 on LH & RH reset panels
F/CTL FCDC 2 FAULT
MEL 27-95-01
-Reset breaker FCDC 2 on RH reset panel
F/CTL FLAP SYS 1 FAULT
MEL 27-51-01
-Recycle breakers SFCC 1 NORM on 721VU pas X14
-Recycle breakers SFCC 1 AVAIL on 721VU pas X13
-Recycle breakers SFCC 1 SLAT on 742VU pas L62
-Recycle breakers SFCC 1 FLAP on 742VU pas L61
F/CTL FLAPSYS2FAULT
MEL 27-51-01
-Recycle breakers SFCC 2 SLAT on 722VU pas T43
-Recycle breakers SFCC 2 FLAP on 722VU pas V40
F/CTL FLAP TIP BRK FAULT
NO GO
- Reset Wing Tip Brake with MCDU
(AT A 27 FLAP/SLAT SFCC 1 (2) FLAP PCU/WTB TEST/RESET)
SFCC/WTB RESET CONFIRM OF SFCC/WTB RESET)
F/CTL FLAP/MCDU DISAGREE
-Check Post Flight Report
NO GO
11
MEL 27-92-02 or
MEL 32-42-05
-Recycle Flight Control Primary Computer (FCPC) 1, 2 and 3
F/CTL IR DISAGREE
NO GO
-Check Post Flight Report
F/CTL L ELEV FAULT
NO GO
-Perform Bite Test of the EFCS ground scanning with MCDU
(ATA 27 -F/CTL -EFCS -EFCS1 -GND SCANNING)
F/CTL L INR AIL FAULT
NO GO
-Perform Bite Test of the EFCS ground scanning with MCDU
(ATA 27 -F/CTL -EFCS -EFCS1 -GND SCANNING)
F/CTL OUTRAIL FAULT H
NO GO
-Perform Bite Test of the EFCS ground scanning with MCDU
(ATA 27 -F/CTL -EFCS -EFCS1 -GND SCANNING)
F/CTL L SIDESTICK FAULT
NO GO
-Check Post Flight Report
F/CTL L+R ELEV FAULT
NO GO
-Perform Bite Test of the EFCS ground scanning with MCDU
(ATA 27 -F/CTL -EFCS -EFCS1 -GND SCANNING)
F/CTL PRIM 1 FAULT
MEL 27-93-01
-Recycle FCPC 1 (Flight Control Primary Computer)
F/CTL PRIM 1 PITCH FAULT
- Recycle FCPC 1 (Flight Control Primary Computer)
F/CTL PRIM 2 FAULT
-Recycle FCPC 2 (Flight Control Primary Computer)
F/CTL PRIM 2 PITCH FAULT
-Recycle FCPC 2 (Flight Control Primary Computer)
F/CTL PRIM 3 FAULT
- Recycle FCPC 3(Flight Control Primary Computer)
F/CTL PRIM 3 PITCH FAULT
F/CTL
F/CTL
F/CTL
F/CTL
GO
GO
GO
GO
12
MEL 27-25-02-A
MEL 27-94-01
Secondary Computer (FCSC) 1 and 2
MEL 27-94-01
Secondary Computer (FCSC) 1 and 2
MEL 27-94-01
Secondary Computer (FCSC) 1 and 2
MEL 27-94-01
Secondary Computer (FCSC) 1 and 2
MEL 27-92-05 or
MEL 27-92-06
13
MEL 27-81-01
SFCC
SFCC
SFCC
SFCC
1
1
1
1
MEL 27-81-01
NO GO
NO GO
NO GO
MEL 27-92-01
MEL 27-92-01
MEL 27-64-01
NO GO
MEL 27-93-05
MEL 27-26-01
MEL 27-26-01
MEL 27-26-01
FUEL A330
FUEL ABNORMAL MAN FWD XFR
-No action
FUEL APU AFT PUMP FAULT
-Reset breakers FCMC 1 and 2 on LH and RH reset panel
FUEL APU LP VALVE FAULT
-Reset breakers FCMC 1 and 2 on LH and RH reset panel
FUEL ENG1 LP VALVE FAULT
-Reset breakers FWC 1 and 2 on LH and RH reset panel
FUEL ENG2 LP VALVE FAULT
-Reset breakers FWC 1 and 2 on LH and RH reset panel
Not applicable
MEL 49-30-01-A
MEL 49-30-03
MEL 28-24-01
MEL 28-24-01
14
MEL 28-40-13-A
MEL 28-51-01-A
or MEL 28-51-01B
NO GO
MEL 28-51-01-A
or MEL 28-51-01B
MEL 28-21-01-A
15
FUEL
FUEL
FUEL
FUEL
MEL 28-21-01-A
MEL 28-27
MEL 28-25-04-C
or 28-27-01 or
28-27-03 or 2827-04
MEL 28-27-05
NO GO
MEL 28-23-01
MEL 28-51-02
HYD A330
HYD B + Y SYS LO PR
-Check Hydraulic levels
HYD B ELEC PUMP FAULT
-Recycle breaker HSMU B + PART G on 721VU position U10
-Recycle breaker HYD PUMP B CTL on 721VU position X12
HYD B ENG 1 PUMP LO PR
-Check Blue Hydraulic level
-Bleed Blue Hydraulic system
HYD B RSVR LO AIR PR
NO GO or MEL
29-30-03-F
MEL 29-2-01 or
MEL29-30-03-D
NO GO
NO GO or MEL
29-30-03-B
NO GO or MEL
29-30-03-F
MEL 29-21-01 or
MEL 29-30-03-D
16
HYD G
HYD G
HYD G
HYD G
NO GO or MEL
29-30-03-E
NO GO or MEL
29-30-03-E
NO GO or MEL
29-30-03-E
NO GO or MEL
29-30-03-B
MEL 29-30-03-H
NO GO or MEL
29-30-03-G
NO GO or MEL
29-30-03-B
NO GO or MEL
29-30-03-C
17
HYD RSVR LO L VL
- Check Hydraulic levels
HYD Y RSVR OVHT
NO GO or MEL
29-30-03-C
A.ICE A330
A.ICE CAPT AOA HEAT
MEL 30-31-04
- Reset breaker PHC1 on LH reset panel
- Perform operational test of the Probe Ice protection with MCDU
ATA 30 -ICE RAIN:HEATING - PHC 1 - TEST
A.ICE CAPT PITOT HEAT
MEL 30-32-02
- Reset breaker PHC1 on LH reset panel
- Perform operational test of the Probe Ice protection with MCDU
ATA 30 -ICE RAIN:HEATING - PHC 1 - TES
A.ICE CAPT PROBES HEAT
MEL 30-31-01
- Reset breaker PHC1 on LH reset panel
- Perform operational test of the Probe Ice protection with MCDU
ATA 30 - ICE RAIN:HEATING - PHC 1 - TEST
A.ICE CAPT TAT HEAT
- Reset breaker PHC1 on LH reset panel
- Perform operational test of the Probe Ice protection with MCDU
ATA 30 -ICE RAIN:HEATING - PHC 1 - TEST
MEL 30-31-05
MEL-30-81-01
MEL 30-21-01
MEL 30-21-01
MEL 30-21-01
MEL 30-21-01
MEL 30-31-01
18
MEL 30-31-05
MEL 30-42-02
MEL 30-42-03
MEL 30-31-03
MEL 30-31-03
NO GO
NO GO
MEL 30-11-01
MEL 30-11-01
MEL 30-11-01
MEL 30-42-02
MEL 30-42-03
MEL 30-31-03
MEL 30-31-03
NO GO
MEL 30-11-01
MEL 30-11-01
NO GO
19
MEL 30-11-01
MEL 30-11-01
MEL 30-31-03
MEL 30-42-02
MEL 30-42-03
MEL 30-31-04
MEL 30-31-02
MEL 30-31-01
MEL 30-11-01
MEL 30-11-01
MEL 30-11-01
EIS A330
EIS DISPLY DISCREPANCY
-Reset breaker DMC 1,2 and 2 on LH and RH reset panel
EIS ECAM DMC 1 FAULT
-Reset breaker DMC 1 on LH reset panel
EIS ECAM DMC 2 FAULT ME 31-62-01-B
-Reset BREAKER DMC2 on RH reset panel
EIS ECAM DMC 3 FAULT
-Reset breaker DMC3 on LH reset panel
EIS EFIS DMC 1 FAULT
-Reset breaker DMC1 on LH reset panel
EIS EFIS DMC 2 FAULT
-Reset breaker DMC 2 on RH reset panel
EIS EFIS DMC 3 FAULT
-Reset breaker DMC 3 on LH reset panel
NO GO
MEL 31-62-01-B
MEL 31-62-01-B
MEL 31-62-01-B
MEL 31-62-01-A
MEL 31-62-01-A
MEL 31-62-01-A
FWS A330
FWS EPC FAULT
MEL 31-56-01
20
- Reset breaker
- Reset breaker
FWC1 FAULT
- Reset breaker
FWC 1+2 FAULT
- Reset breaker
2 FAULT
- Reset breaker
SDAC 1 FAULT
- Reset breaker
SDAC 1+2 FAULT
- Reset breaker
SDAC 2 FAULT
- Reset breaker
RECORDER A330
RECORDER DFDRFAULT
- Recycle breaker FDIU/DFDR on panel 722VU position F42
RECORDER FDIU FAULT
- Recycle breaker FDIU/DFDR on panel 722VU position F42
BRAKES A330
BRAKES A/SKID NWS OFF
Not applicable
- No action necessary (Switch A/SKID & N/W STRG is set to OFF)
BRAKES ANTI SKID FAULT
- Recycle A/SKID & N/W STRG switch on F/O instrument panel
BRAKES AUTO BRAKE FAULT
NO GO
MEL 32-42-02 or
32-42-04
21
L/G A330
L/G DOORS NOT CLOSED
NO GO
-Perform visual check of landing gear doors
-Reset breaker LGCIU 1 and 2 on LH and RH reset panel
L/G GEAR NOT DOWN
Not applicable
-No action if no Post Flight Report
L/G GEAR NOT DOWNLOCKED
Not applicable
-Reset breaker LGCIU 1 and 2 on LH and RH reset panel
L/G GEAR NOT UPLOCKED
Not applicable
-Reset breaker LGCIU 1 and 2 on LH and RH reset panel
L/G GEAR UPLOCK FAULT
FCOM 2-04-25
-Check uplock assembly of all gears
L/G L LENGTHENING FAULT
FCOM 2-04-25
-Check for damage to the shortening mechanism or the prox. sensor target LH
L/G R LENGTHENING FAULT
FCOM 2-04-25
-Check for damage to the shortening mechanism or the prox sensor target RH
L/G LGCIU 1 FAULT
MEL 32-31-01
-Reset breaker FWC 1 and LGCIU 1 on LH reset panel
-Reset breaker FWC 2 and LGCIU 2 on RH reset panel
L/G LGCIU 1+2 FAULT
MEL 32-31-01
-Reset breaker FWC 1 and LGCIU 1 on LH reset panel
-Reset breaker FWC 2 and LGCIU 2 on RH reset panel
L/G LGCIU 2 FAULT
MEL 32-31-01
-Reset breaker FWC 1 and LGCIU 1 on LH reset panel
-Reset breaker FWC 2 and LGCIU 2 on RH reset panel
L/G RETRACTION FAULT
FCOM 2-04-25
-Check for damage to prox sensors targets or attachment brackets
L/G SYS DISAGREE
NO GO
-Reset breaker LGCIU 1 and 2 on LH and RH reset panel
-Check for damage to the down lock proximity sensors or targets
WHEEL A330
WHEEL HYD SEL VALVE
- Recycle A/SKID & N/W STRG switch on F/O instrument panel
WHEEL N/W STRG FAULT
- Recycle A/SKID & N/W STRG switch on F/O instrument panel
- Reset breaker LGCIU 1 and LGCIU 2 on LH and RH reset panel
WHEEL TIRE LO PR
- Recycle A/SKID & N/W STRG switch on FIG instrument panel
- Unsatisfactory tire pressure (Adjust tire pressure)
NO GO
MEL 32-51-01
NO GO
NAV A330
NAV ADR 1 FAULT
-Reset FWC1 and FWC2 on LH and R panel
-Check Post Flight Report
NAV ADR 1+2 FAULT
-Reset FWC1 and FWC2 on LH and R panel
-Check Post Flight Report
NAV ADR 1+3 FAULT
-Reset FWC1 and FWC2 on LH and R panel
MEL 34-10-01-8
MEL 34-10-01-8
MEL 34-10-01-B
22
23
APU A330
APU FAULT
-Check the Post Flight Report
APU FIRE DET FAULT
-Recycle breaker FDU LOOP 8 APU on panel 721VU position P08
-Recycle breaker FIRE LOOP A APU on panel 742VU position D80
APU FIRE LOOP A FAULT
-If Loop A OK . Faulty FDU (13WG)
-Reset FWC 1 and FWC 2 on LH and RH reset panel
APU FIRE LOOP 8 FAULT
-If Loop B OK . Faulty FDU (13WG)
-Reset FWC 1 and FWC 2 on LH and RH reset panel
MEL 49-11-01
MEL 26-13
MEL 26-13-01
MEL 26-13-01
DOOR A330
DOOR AFT CARGO
MEL 52-71-01-B
- Check proximity sensor and target
-Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT)
DOOR AVIONIC
MEL 52-71-01-B
.Check proximity sensor and target
-Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT)
DOOR BULK CARGO
MEL 52-71-01-B
-Check proximity sensor and target
-Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT)
DOOR FWD CARGO
MEL 52-71-01-B
-Check proximity sensor and target
-Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT)
DOOR L AFT CABIN
MEL 52-71-01-B
-Check proximity sensor and target
-Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT)
DOOR L EMER EXIT
MEL 52-71-01-B
-Check proximity sensor and target
-Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT)
DOOR L FWD CABIN
MEL 52-71-01-B
-Check proximity sensor and target
-Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT)
DOOR L MID CABIN
MEL 52-71-01-B
-Check proximity sensor and target
-Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT)
DOOR POS DET 1 FAULT
MEL 52-71-01-A
-Reset CPC 1 and CPC 2 on LH and RH reset panels
-Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT)
DOOR POS DET 1+2 FAULT
MEL 52-71-01-A
-Reset CPC 1 and CPC 2 on LH and RH reset panels
-Recycle breaker DOORS & SLIDES CTL on panel 721VU position N09
-Recycle breaker DOORS & SLIDES CTL on panel 722VU position P41
DOOR POS DET 2 FAULT
MEL 52-71-01-A
-Reset CPC 1 and CPC 2 on LH and RH reset panels
-Perform system test of PSCU on MCDU (ATA 52 -DOORS -PROXIMITY SW CTL UT)
24
CONFIG A330
CONFIG FLAPS NOT IN T.O. RANGE
-Check Post Flight Report
-Reset FWC 1 and FWC 2 on LH and RH reset panel
CONFIG L SIDESTICK FAULT
-Check Post Flight Report
-If there is no message, no action is necessary
CONFIG R SIDESTICK FAULT
CONFIG
CONFIG
CONFIG
CONFIG
CONFIG
NO GO
Apply ECAM
procedure
Apply ECAM
procedure
NO GO
NO GO
NO GO
NO GO
NO GO
ENG A330
ENG THRUST LOSS
-Reset breaker ZONE CONT on RH reset panel
ENG ALL ENG FLAME OUT
-Check fuel filters
ENG THR LRVERS NOT SET
-Operational message, no further action required
ENG T.O. THRUST DISAGREE
-Check Post Flight Report for defective LRU(s)
ENG THRUST LOSS
MEL 73-30-03-B
NO GO
MEL 73-20-01
NO GO
MEL 73-30-03-B
25
ENG1 A330
ENG1 BLEED STATUS
Apply ECAM procedure
-Reset breaker EIVMU 1 on LH reset panel
ENG1 CTL SYS FAULT
NO GO
-Recycle breaker FADEC A ENG 1 on panel 742VU position Q73
-Recycle breaker FADEC B ENG 1 on panel 722VU position D44
ENG1 EGT OVERLIMIT
Not applicable
-Perform visual check of engine
ENG1 EIU FAULT
MEL 73-25-02
-Reset breaker EIVMU 1 on LH reset panel
-Reset breaker FCU 1 on LH reset panel
ENG1 FADEC FAULT
NO GO
-Reset breaker SDAC 1 & 2 on LH and RH reset panel
-Reset breaker FCU 1 on LH reset panel
ENG1 FADEC OVHT
NO GO
-Check for excessive heat near the EEC (nacelle anti-ice duct)
ENG1 FADEC SYS FAULT
NO GO
-Reset breaker EIVMU 1 on LH reset panel
-Recycle breaker FADEC A ENG 1 on panel 742VU position Q73
-Recycle breaker FADEC B ENG 1 on panel 722VU position D44
ENG1 FIRE DET FAULT
-Perform the bite test of the FDU with MCDU
(ATA 26 Fire Prot -Engines -FDU -Test)
ENG1 FIRE LOOP A FAULT
-Perform the bite test of the FDU with MCDU
(ATA 26 Fire Prot -Engines -FDU -Test)
ENG1 FIRE LOOP B FAULT
-Perform the bite test of the FDU with MCDU
(AT A 26 Fire Prot -Engines -FDU -Test)
ENG1 FUEL FILTER CLOG
-Check fuel pump filter
-Check fuel pump filter differential switch
ENG1 HP FUEL VALVE
-Perform FADEC system static test with MCDU
(AT A 70-80 Engine -EEC 1 -System test)
ENG1 IGN A FAULT
-Reset breaker EIVMU 1 on LH reset panel
ENG1 IGN B FAULT
-Reset breaker EIVMU 1 on LH reset panel
ENG1 IGN A+B FAULT
NO GO
MEL 26-12-01
MEL 26-12-01
NO GO
NO GO
MEL 74-31-01 or
74-31-03-A
MEL 74-31-01 or
74-31-03-A
MEL 74-31-01 or
74-31-03-A
26
NO GO
Apply ECAM procedure
NO GO or
MEL 79-34-01-A
ENG2 A330
ENG2 BLEED STATUS
Apply ECAM procedure
-Reset breaker EIVMU 2 on RH reset panel
ENG2 CTL SYS FAULT
NO GO
-Recycle breaker FADEC A ENG 2 on panel 742VU position Q73
-Recycle breaker FADEC B ENG 2 on panel 722VU position D44
ENG2 EGT OVERLIMIT
Not applicable
-Perform visual check of engine
ENG2 EIU FAULT
MEL 73-25-02
-Reset breaker EIVMU 2 on LH reset panel
-Reset breaker FCU 2 on LH reset panel
ENG2 FADEC FAULT
NO GO
-Reset breaker SDAC 1 & 2 on LH and RH reset panel
-Reset breaker FCU 2 on LH reset panel
ENG2 FADEC OVHT
NO GO
-Check for excessive heat near the EEC (nacelle anti-ice duct)
ENG2 FADEC SYS FAULT
NO GO
-Reset breaker EIVMU 2 on LH reset panel
-Recycle breaker FADEC A ENG 2 on panel 742VU position Q74
-Recycle breaker FADEC B ENG 2 on panel 722VU position D49
27
NO GO
MEL 26-12-01
MEL 26-12-01
NO GO
NO GO
MEL 74-31-01 or
74-31-03-A
MEL 74-31-01 or
74-31-03-A
MEL 74-31-01 or
74-31-03-A
28