You are on page 1of 36

DESIGN CALCULATIONS REPORT OF STEEL

STRUCTURE

6-EB

REV - 0

DATE: 15-June-2016

TYPE-1

TABLE OF CONTENTS
Sr. No.

Description

General Information

Loading Data

Load Combination & Codes

STAAD Design Input

STAAD Design Output

Connection Design

Fixing Anchor Design

Conclusion

GENERAL INFORMATION
Steel Elements are meant to support framing of architectural elements as
mentioned below.
These steel elements are meant to withstad impact of wind load at an effective
wind speed = 43.2 m/s, having 3s gust effect as per design code
Steel elements are having Min. Fy = 275 N/mm2
Steel connectors between steel elements are Min. of Grade 8.8 bolts
& welds with Fy = 220 N/mm2
Steel Connectors with concrete is Anchor bolts from MKT
Grade of concrete is Min. of C35 (Fck = 35 N/mm2)
Concrete is considered to be Cracked type.
Loadings are accounted as actual and forces and stresses are considered as
per load combinations from design code
Software used for design analysis are STAAD.Pro & MKT
Other connection checks are as per design code values
STANDARD WEIGHT OF CLADDING PANELS
DESCRIPTION

MATERIAL

UNIT WEIGHT
(kg/m)

Mullion
Transom
Louver Blade

Aluminum
Aluminum
Aluminum

4
4
29

DESCRIPTION

MATERIAL

UNIT WEIGHT
(kg/m2)

Glazed CW
Glass Box
Alum. Panel
Polycarbonate
Corton Steel
GRC Panel
Terracota
Ceramic Slab
Limestone

30mm thick glass


Glass
Aluminum
Polycarbonate
Steel
concrete
tiles
Ceramic
Stone

40
25
20
35
35
55
85
85
85

Graphic concrete

Concrete

85

DESCRIPTION

MATERIAL

Insulation
Backspan Cladding
Brackets & Accessories

30mm thick glass

UNIT WEIGHT
(kg/m2)
10
9.42
1

LOADING DATA
DEAD LOAD
Self weight of all the steel elements as per density of 7850 kg/m3 is considered
as dead load component
5% increase in self weight is accounted for connectors and connection plates.
Maximum Spacing of Load carrying members

2.4

Height of assembly

5.8

Total points on which loads are supported

Perforated aluminum panel

0.2

Insulation

0.2

Dead Load Calculation per frame


2.4

(m)

0.2

kN/m2

(m)

0.2

kN/m2

(m)

0.115

kN/m2

(m)

0.3

kN/m2

Total Load
=

WIND LOAD
Wind load calculations
Maximum Spacing between identical framing

2.4

Height of assembly

5.8

Total points on which loads are supported

Basic Wind Spee Considered

45

(3s gust at 10m)

Height of Structure is less than 10m


Wind calculation is in accordance with BS 6399 Part-II: 1997
V
Sa
Sd
Ss
Sp
Sb

=
=
=
=
=
=

Design wind speed

25
1
1
1
1
1.73
=

Thus basic wind pressure

m/s

43.2

an hourly mean speed

m/s

1.14

Maximum Cpe

0.77

Min. Cpi

-0.3

Max + Pressure

1.22

kN/m2

Max Suction

1.71

kN/m2

kN/m2

CODES & LOAD COMBINATIONS

Design Codes Considered are


BS 5950-1:2000

Structural Use of Steelwork in Building

BS 6399-1:1996

Code of practice for dead and imposed loads.

BS 6399-2:1997

Code of practice for Wind Load

BS 6399-3:1988

Code of practice for Imposed Roof Loads

BS 2971

Class 2 Arc Welding of Carbon Steel Pipework

Load Combinations
Serviceability Load Combination

DL + WLS

Serviceability Load Combination

DL + WLP

Strength Load Combination

1.4DL + 1.4WLS

Strength Load Combination

1.4DL + 1.4WLP

STAAD INPUT

Wire Frame View

Isometric View

Sections

Wind Load (Suction)

Dead Load

Wind Load (Pressure)

Dimension

Support

STAAD Output

Utilization Ratios (Steel Elements)

Displacement @ Ht = 5800mm is 8.581mm


Allowable Deflection =5800/250 = 23.2mm, hence OK in Deflection

Reaction At Connection of Steel & RCC

CONNECTION DESIGN
ALLOWABLE LOADS OF GRADE 8.8 GALVANIZED STEEL BOLTS FROM
AAMA TIR A9-91 (S275 Ply)
Steel Grade

S275

Bolt Grade

8.8

Ub

800

N/mm2

(Min. Tensile strength of bolt)

Yb

640

N/mm2

(Min. Yield strength of bolt)

Ft

320

N/mm2

(Allowable Tensile stess of bolt)

Fv

184.75

N/mm2

(Allowable shear stress of bolt)

Fb

444

N/mm2

(Allowable bearing of steel)

Pt

Ft * As

(Allowable tension of bolt)

Ps

Fv * Ar

(Allowable shear of bolt)

Pbb

Fb*Db*tp

(Allowable bearing of bolt)

Fs
Ps

Ft
Pt

<=

Db

Bolt Diameter

tp

Thickness of ply

3Db

Min. Spacing bewteen bolts

1.5Db

Min. Edge distance of bolts

Forces At Connection (Beam: 16, Node: 1)


Fx
=
0.7
Fy
=
0.3
Fz
=
3.5
Mx
=
0.005
My
=
1
Mz
=
0.5

Forces At Connection (Beam: 27, Node: 20)


Fx
=
1
Fy
=
1
Fz
=
1
Mx
=
0

(Combined shear and tension

My
Mz

=
=

0
0

Forces At Connection (Beam: 6, Node: 6)


Fx
=
34
Fy
=
1
Fz
=
1
Mx
=
0
My
=
0.2
Mz
=
0.2

Diameter of connection bolt

16.00

mm

Cross sectional area of bolt

144.10

Shear force in bolt due to Fx

0.35

kN

Shear force in bolt due to Fy

1.67

kN

Tensile force in bolt due to Fz

0.50

kN

Shear force in Bolt due to Mx

0.00

kN

Shear force in Bolt due to My

4.00

kN

Tensile force in bolt due to Mz

4.00

kN

Resultant shear in bolt

4.35

kN

Resultant tensile in bolt

4.03

kN

Unity Check

Bearing of plate

0.6698459 <=
42.62

kN

mm2

Diameter of connection bolt

8.00

Cross sectional area of bolt

36.10

Shear force in bolt due to Fx

0.03

kN

Shear force in bolt due to Fy

0.03

kN

Tensile force in bolt due to Fz

0.03

kN

Shear force in Bolt due to Mx

0.00

kN

Shear force in Bolt due to My

0.00

kN

Tensile force in bolt due to Mz

0.00

kN

Resultant shear in bolt

0.04

kN

Resultant tensile in bolt

0.03

kN

Unity Check

0.006

<=

Bearing of member

14.08

kN

FIXING ANCHOR DESIGN

mm
mm2

CONCLUSION

All The steel elements are SAFE


All the connections are SAFE

T OF STEEL

Page No.
3
4
5
8
10
13
15
16

al elements as

load at an effective

e considered as

kg/m3 is considered

connection plates.
m
m
No's
kN/m2
kN/m2

0.4800

kN/m

0.0000

kN

0.0000

kN

0.0000

kN

0.4800

kN/m

1.1520

kN/m

m
m
No's
m/s

ind Load (Pressure)

BOLTS FROM

in. Tensile strength of bolt)

in. Yield strength of bolt)

llowable Tensile stess of bolt)

llowable shear stress of bolt)

llowable bearing of steel)

nsion of bolt)

ear of bolt)

aring of bolt)

ombined shear and tension)

<

26.63

<

49.63

(Hence OK)

<

6.06

<

11.55

(Hence OK)