You are on page 1of 2

PHILEC Brand Distribution Transformers

Our PHILEC brand transformers have been the renowned market leader in the Philippine
distribution transformers market. The PHILEC brand has been the brand of choice of some of the
leading power generating and distribution utilities nationwide.
Our pole-mounted, oil-filled transformers are specifically designed to service the power
requirements of residential, commercial light industrial loads as well as some diversified power
specifications. These transformers were designed to conform to the usual service conditions
described in ANSI C57.12.00, General Requirements for Liquid-Immersed Distribution, Power and
Regulating Transformers.
PHILEC also produces Amorphous core Distribution Transformers (AMDT) which have been proven
to provide big cost savings in the long run due to its low No-Load Losses (NLL).

External Features
HIGH VOLTAGE BUSHINGS

BOLTED COVER CLAMPS

Both the cover-mounted and tank-wall mounted high voltage


bushings are made of wet process porcelain suitable for both
copper and aluminum conductors. It serves as the conduit
between the high voltage line and the transformer tank.

High quality elastic oil-resistant gaskets are used to ensure


that an even pressure around the rim provides an effective
seal from the environment to help prolong the life of the
transformers.
TANK GROUNDING PROVISIONS

LOW VOLTAGE GROUNDING PROVISIONS

Provided to electrically ground the tank and cover to help


prevent damage to the transformer during electrical surges.

Provides for grounding the low voltage neutral and has a


tapped hole with 0.50 diameter 13 NC thread.

EXTERNALLY OPERATED NO-LOAD TAP CHANGER

LOW VOLTAGE BUSHINGS

Allows rapid and convenient changing of high voltage tap


connection at no-load without contaminating the internal parts
of the transformer. Philec transformers provides users a choice
of up to five (5) primary voltage settings

Furnished with a single or double eyebolt or spade terminal


depending on the ratings of the unit. These are usually made
of the same materials as the high voltage bushings.
COVER AND WELDED TANK
Encloses the unit and is manufactured from hot-rolled steel
sheets and pressure tested to ensure a leak free enclosure.
Tanks and covers are grit blasted or chemically treated to
remove every trace of scale, rust or oil, thus preparing the
surface for better paint adhesion. The outer and inner
surfaces are primed with epoxy primer for rust prevention and
then the outer surface is coated with polyurethane
PRESSURE RELIEF VALVE
Serves as a gateway for gradually venting off excess
pressure and designed to operate under environmental
conditions encountered during outdoor applications.

Standard Tests

LIFTING LUGS
These are made of hot-rolled steel welded to the tank
designed to help support the weight of the transformer
during transport.
NAMEPLATE
Placed in a readily accessible and visible location, these
helps provide easier identification during servicing,
monitoring and maintenance.
SUPPORT LUGS
The lugs are made of hot-rolled steel which are welded to the
tank and holds the transformer firmly in place during
operation.
RADIATORS
These are added in higher KVA units as an additional cooling
surface and are made of the same materials as that of the
tank.

To ensure the quality and reliability of our Distribution Transformers, the following tests are conducted on all finished units
before these are delivered to our customers:
Routine Tests

Type Tests

Turns Ratio Test


Voltage Ratio Test
No Load Loss & Load
Loss Tests
Impedance Voltage Test
Applied Potential Test
Induced Potential Test

Impulse Test
Temperature Rise
Test

Contact us:

FIRST PHILEC MANUFACTURING TECHNOLOGIES CORP. (FPMTC)


Central Sales and Marketing (CSM)
Manila East Road, Bo. Dolores Taytay, Rizal, Mobile: +639165909738
Tel: (632) 658-4911 - 15/ 658-4981 83; Fax: (632) 706-7260
Email: marketing@firstphileceu.com, website: www.firstphilec.com

A Lopez Group Company

Internal Features
CORE CLAMP

EFFECTIVE SEALING GASKETS

Aside from holding the core and windings in place, the core
clamp also provides extra strength to withstand mechanical
stresses during operation.

The use of oil resistant materials ensure that the interior of


our transformers are well-protected from the elements which
prevents early or premature deterioration.

DIELECTRIC FLUID

CLAMP ANGLES

Philec uses either petroleum based fluid which was refined for
use in electrical purposes, inhibited oil which contains ditertiary butyl/paracresol or the environmentally-friendly soyabased FR3 when specified.

Ensures that the core coil assembly is effectively attached to


the tank.
COIL SUPPORT
Philec uses compatible wood materials to hold the coil in
place and restrain it during short-circuit conditions.

CORE COIL ASSEMBLY


The core utilizes Philecs superior transformer insulation
system
and isDimensions
permanently centered in the tank using a close
Standard
fitted steel frame.
PRODUCT DESCRIPTION
HV Rating (V):
7620/13200Y
13800
13200

LV Rating (V):
120/240
139/277
240/480

BIL : 95 KV

BIL : 30 KV

HV Rating (V):

LV Rating (V):

14400/24940Y

120/240
139/277
240/480

BIL : 125 KV

BIL : 30 KV

HV Rating (V):

LV Rating (V):

34500Grd.Y/19920
BIL : 150 KV

120/240
139/277
120/240 x 139/277
240/480

13200Grd.Y/7620
BIL : 30 KV
BIL : 95 KV
HV Rating (V):
2400/4160Y
BIL : 60 KV
3600/6240Y
4800/8320Y
BIL : 75 KV

LV Rating (V):
120/240
139/277
240/480
BIL : 30 KV

KVA
10
15
25
37.5
50
75
100
167
250
333
500
10
15
25
37.5
50
75
100
167
250
333
500
10
15
25
37.5
50
75
100
167
250
333
10
15
25
37.5
50
75
100
167
250
333

A
600
600
650
680
715
800
845
980
1070
1100
1300
600
600
650
715
715
800
795
915
1020
1100
1220
600
600
650
715
715
800
800
920
1050
1090
610
600
650
680
715
750
780
900
950
1000

Dimension (mm)
B
C
550
550
580
600
655
820
900
1060
1290
1280
1350
550
550
580
600
655
820
900
1060
1375
1330
1230
580
580
600
650
730
820
980
1110
1390
1350
550
550
580
600
700
850
980
1100
1290
1280

650
685
750
800
875
925
925
955
1005
1055
1200
650
685
750
790
875
900
955
1005
1005
1055
1200
685
685
855
875
875
900
925
955
1005
1055
685
685
855
875
875
900
925
955
1005
1055

D
930
965
1035
1080
1155
1205
1205
1235
1285
1335
1480
980
1015
1080
1120
1205
1230
1285
1335
1335
1385
1530
1085
1085
1255
1275
1275
1300
1325
1355
1405
1455
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a

Wt. (Kg)

FIGURE

136
145
191
263
305
405
450
706
900
1010
1338
137
140
189
250
295
405
456
650
878
1007
1348
135
146
190
266
310
400
460
680
880
1000
130
135
182
240
267
344
422
618
821
1014

* Dimensions and weights are typical values

A Lopez Group Company