You are on page 1of 167

Daikin Airconditioning UK Ltd

Daikin Airconditioning UK Ltd

Head Office

General Catalogue 2007

Daikin Airconditioning UK Limited


The Heights, Brooklands, Weybridge, Surrey KT13 0NY

1st July 2007

Tel 0845 6419000 Fax 0845 6419109

General Catalogue 2007

www.daikin.co.uk

issue one

Daikin units comply with the European regulations that


guarantee the safety of the product.

ISO14001 assures an effective environmental management


system in order to help protect human health and the
environment from the potential impact of our activities,
products and services and to assist in maintaining and
improving the quality of the environment.

Daikin Europe N.V. participates in the Eurovent Certification


Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP)
and Fan Coil Units (FC); the certified data of certified models are
listed in the Eurovent Directory. Multi units are Eurovent certified for
combinations up to 2 indoor units. VRV products and FWD-units are
not within the scope of the Eurovent Certification Programme.

Daikin products are distributed by:

www.daikin.co.uk

1571UKCover_artwork.indd 1

The present catalogue is drawn up by way of information only


and does not constitute an offer binding upon Daikin Europe N.V..
Daikin Europe N.V. has compiled the content of this catalogue to
the best of its knowledge. No express or implied warranty is given
for the completeness, accuracy, reliability or fitness for particular
purpose of its content and the products and services presented
therein. Specifications are subject to change without prior notice.
Daikin Europe N.V. explicitly rejects any liability for any direct or
indirect damage, in the broadest sense, arising from or related
to the use and/or interpretation of this catalogue. All content is
copyrighted by Daikin Europe N.V..

UKEPCEN07-500 / 06.07 / Swim / La Movida


The present publication supersedes EPCEN07-500_P
Printed by Portishead Press using vegetable oil based inks, on 75% recycled paper.

issue one

Daikin Europe N.V. is approved by LRQA for its Quality


Management System in accordance with the ISO9001
standard. ISO9001 pertains to quality assurance regarding
design, development, manufacturing as well as to services
related to the product.

24/7/07 12:08:00

1571UKCover_artwork.indd 2

24/7/07 12:08:14

Foreword

DAIKIN AIRCONDITIONING UK LTD


Daikin Airconditioning UK Ltd is a wholly owned subsidiary of Daikin
Europe N.V. The focus of our business is sales and distribution of Daikin air
conditioning products whilst fully utilising the advantage of our European
Group Manufacturing Division. Daikin Airconditioning UK Ltd is a nationwide
organisation with its headquarters in Weybridge, Surrey. Strategically
situated regional sales offices achieve efficient response combined with
administration, distribution and field quality services departments.

DAIKIN EUROPE N.V.


Daikin Europe N.V. is the European sales and manufacturing headquarters
responsible for distribution of air conditioning equipment for residential,
commercial and industrial use. As a 100% subsidiary of Daikin Industries
Ltd (Japan), a global leader in the air conditioning systems industry, its main
focus is to respond to the evolving requirements of customers throughout
Europe, Russia, Africa and the Middle East.

London Head Office

Manchester Office

Daikin Airconditioning UK Limited


The Heights, Brooklands, Weybridge,
Surrey KT13 0NY
Tel 0845 6419300

Daikin Airconditioning UK Limited


Quay Plaza, Unit G35, Salford Quays,
Manchester M50 3AG
Tel 0845 6419340

Bristol Office

Glasgow Office

Daikin Airconditioning UK Limited


Airways, Midland Way, Thornbury,
Bristol BS35 2JX
Tel 0845 6419320

Daikin Airconditioning UK Limited


Unit 2, Glasgow Airport Business Park
Marchburn Drive, Paisley PA3 2SJ
Tel 0845 6419330

Birmingham Office

South Coast Office

Daikin Airconditioning UK Limited


Unit 8, Holly Park, Spitfire Road,
Birmingham, West Midlands B24 9PB
Tel 0845 6419370

Daikin Airconditioning UK Limited


7 Tabernacle Walk, Blandford,
Dorset DT11 7DL
Tel 0845 6419380

1571 UK Intro_pp1-9.indd 1

24/7/07 12:10:23

Daikin Airconditioning UK Ltd, Weybridge Head Ofce

Table of Contents
Foreword
Table of contents
Environmental awareness
Energy labelling

1
2
4
6

Air Purifier
Photocatalytic air purifier

Residential & Commercial


Wall mounted units
Flexi type units
Floor standing units
Concealed ceiling units
Cassette units
4-Way blow ceiling suspended cassettes
Ceiling suspended units

11
24
29
31
45
59
61

Twin/triple/double twin applications


Multi model applications
Altherma
Air handling unit connections

69
74
85
89

VRV
VRVIII-S
VRVIII air-cooled outdoor units
VRV-WII water-cooled outdoor units
Indoor units
HRV

94
96
102
103
117

Control Systems
Centralised control systems
Network Solutions

121
122

Applied Systems
Air-cooled
Remote evaporator
Water-cooled
Remote condenser
Fan coil units

129
129
151
151
160

To consult the explanation of the pictogrammes, please refer to page 163 of this catalogue.

1571 UK Intro_pp1-9.indd 3

24/7/07 12:11:12

Environmental Awareness
AIR CONDITIONING AND THE ENVIRONMENT
Air conditioning systems provide a significant level of indoor
comfort, making possible optimum working and living
conditions in the most extreme climates. In recent years,
motivated by a global awareness of the need to reduce the
burdens on the environment, some manufacturers including
Daikin have invested enormous efforts in limiting the negative
effects associated with the production and the operation of
air conditioners. Hence, models with energy saving features
and improved eco-production techniques have seen the
light of day, making a significant contribution to limiting the
impact on the environment.

1571 UK Intro_pp1-9.indd 4

24/7/07 12:11:45

DAIKINS COMMITMENT TO THE ENVIRONMENT


The pioneering concern for the environment and natural resources is a part of the entire global Daikin operation at all
levels: from product design, manufacturing processes, down to the responsibility each individual Daikin employee takes
for the environment.
This commitment is reflected in three areas: reducing waste in manufacturing and operations, recycling materials and
equipment, and designing and producing energy-efficient climate control equipment.

REDUCING WASTE IN MANUFACTURING AND BUSINESS OPERATIONS


In 1998, Daikin Europe N.V. became the first air conditioning manufacturer in Europe to obtain ISO 14001 environmental
certification. In addition, since 2004, not only the manufacturing plants but Daikin sales companies as well have obtained
ISO 14001 certification, underlining Daikins commitment to the environment at all levels of our organisation.
These certified environmental plans include the reduction of waste at all levels. Our environmental targets are high: Daikin
Europe N.V. is committed to a zero waste policy whereby as much as possible of its by products can be reused, recycled
or recovered as useful resources.

RECYCLING MATERIALS AND EQUIPMENT


Daikin Europe N.V. is firmly committed to recycling materials in all areas of its operations. Wastewater is treated before being
discharged into the city drainage system, with the recovered sludge being a useful ingredient in cement manufacturing.
Other waste is also carefully sorted and recycled, supported by a continually evolving factory layout that encourages
the optimum use of resources. In addition to recycling, we invest significantly in returnable packaging. The same high
demands are also imposed on our suppliers.
Daikin Airconditioning UK Ltd is raising the bar in the air conditioning industry by launching a first of its kind recycling
scheme in preparation for the future environmental demands of the market. The recycling scheme, part of the leading air
conditioning specialists commitment to act in an environmentally responsible way, offers installers of Daikin equipment
the service of taking back the existing air conditioning that has reached the end of its life.
Once collected from site by Daikin Airconditioning UK Ltd, the end of life air conditioning equipment will be transported
to a recycling facility, where it is dismantled in such a way that any hazardous substances are destroyed or reprocessed.
Thereafter, up to 95% of the residual matter will be reclaimed for further use.
Eliminating waste and optimum recycling reduce raw material consumption and contribute to efficient manufacturing
and operating processes, meaning fewer burdens on the environment.

ENERGY EFFICIENT CLIMATE CONTROL EQUIPMENT


Daikins commitment to being a leader in environmental developments has led to a string of innovations in climate control
equipment:
Daikins use of inverter technology for example reduces start-up time by 33% and allows the compressor to consume
only the power it actually needs to meet the cooling/heating needs of the moment.
Linking the use of inverter technology to reluctance DC compressor motors has further improved efficiency, allowing
Daikin units to obtain the highest efficiency ratings in the market.
Daikin also produces computerised air conditioning monitoring and control systems designed to ensure maximum
energy efficiency at all times, such as Daikins latest I-controller technology which offers customers refined and energy
efficient control of Daikin heat recovery air conditioning installations, including remote monitoring via the Internet.
This list of innovations could be expanded endlessly. More importantly, it clearly demonstrates that technological innovation
and concern for the environment can go hand in hand. At Daikin, these environmental priorities form an integral part of
our corporate culture and are reflected in all of our products.
Choosing Daikin means you can be sure that the cooling systems you use are the safest possible for the environment.

1571 UK Intro_pp1-9.indd 5

24/7/07 12:11:49

Energy Labelling

Energy labelling is part of a wider European Climate Change


program that targets energy efficiency as one method of
reducing CO2 emissions in order to meet the targets of the
Kyoto protocol. By this means the European Commission
hopes that improved awareness will result in customers
purchasing the most economical (ecological) answer to their
needs.

WHAT?
The energy label provides information on the energy
consumption of the unit. Air conditioning units (with cooling
capacity 12kW) are classified in seven different categories
(A to G), according to their energy consumption and color
coded according to the category to which they belong. The
most energy efficient units will be included in the A category,
indicated by a green arrow on the label less efficient units
will belong in G class, indicated by a red arrow on the label.
The end user can easily compare the efficiency of equal types
of units from different brands.

Energy
Manufacturer
Outside unit
Inside unit
More efficient

A
B
C
D
E

THE LABEL?
WHAT IS MENTIONED ON THE LABEL?
Logo and name of manufacturer; name of indoor and
outdoor unit (*)

F
G

Energy efficiency class of the unit in cooling mode:

Less efficient
Annual energy consumption,
kWh in cooling mode

EER > 3.20

_ EER > 3.00


3.20 >

Full load (the higher the better)

_ EER > 2.80


3.00 >

Type

Cooling only

_ EER > 2.60


2.80 >

Cooling + Heating
Air cooled

_ EER > 2.40


2.60 >

_ EER > 2.20


2.40 >

_ EER
2.20 >

(Actual consumption will


depend on how the apliance is used
and climate)

Cooling output
Energy efficiency ratio

kW

Water cooled
Heat output

kW

Heating performance
A: higher

G: lower

Noise
(dB(A) re 1 pW)

Further information is contained


in product brochures
Air-conditioner
Energy Label Directive 2002/31/EC

1571 UK Intro_pp1-9.indd 6

24/7/07 12:11:50

INDICATED ANNUAL ENERGY CONSUMPTION


This figure indicates the approximate amount of energy consumed per year by the unit, based on a standard household
model. The annual consumption is calculated by multiplying the total power input by an average of 500 hr per year IN
COOLING MODE AT FULL LOAD.
In order to calculate the cost of annual energy consumption, you merely multiply this figure by your electricity tariff.

COOLING OUTPUT
Cooling output is defined as the cooling capacity in kW of the appliance, operating in cooling mode at full load. It is
important to choose an air conditioning unit with a rated output sufficient for your cooling/heating requirements. An
oversized unit can result in frequent on/off cycling, which shortens its service life - an undersized unit will not provide
adequate cooling/heating. To determine the appropriate output, contact the manufacturer or your local dealer/installer.

ENERGY EFFICIENCY RATIO (EER)


This is the cooling output of the unit divided by the amount of electricity the unit requires to deliver it (total power input).
In other words, the higher the EER, the greater the energy efficiency.

TYPE
TYPE OF UNIT: it indicates if the unit is a cooling only or cooling/heating system
COOLING MODE: it indicates if the unit is air cooled or water cooled

HEATING OUTPUT
Heating output is defined as the heating capacity in kW of the appliance, operating in heating mode at full load.

ENERGY EFFICIENCY CLASS OF THE UNIT IN HEATING MODE:


A

COP > 3.60

_ COP > 3.40


3.60 >

_ COP > 3.20


3.40 >

_ COP > 2.80


3.20 >

_ COP > 2.60


2.80 >

_ COP > 2.40


2.60 >

_ COP
2.40 >

Noise level: only for portable units.

(*): For multi-models Daikin chooses only to mention 1 outdoor unit with a maximum of 2 indoor units (wall mounted
type) - for other units we refer to the multi brochure.

1571 UK Intro_pp1-9.indd 7

24/7/07 12:11:50

MC707VM-S
Photocatalytic air purifier

IMPROVED OUTLOOK

IMPROVED PERFORMANCES

MORE COMFORT

New design aiming to suit better in


any interior dcor.

Due to the Daikin Flash Streamer


technology:
- a bigger number of allergens are
resolved
- adjuvant* decomposition
performance improved
- deodorising and disinfecting
power increased

Extended applicable room size = up


to 48m2
Quiet operation: 16dB(A) in silent
mode

(*Adjuvant substances are substances that adhere


to allergens, making them even more harmful, e.g.
diesel exhaust particles.)

Pre-filter (with catechin)


Removes large dust
particles and pet hairs.

Bio-antibody filter
Airborne viruses are
captured and removed.

Plasma ionizer
Dust and pollen are
positively charged and sent
to the electrostatic filter.

Dirty air

1571 UK Intro_pp1-9.indd 8

24/7/07 12:11:50

MC707VM-S

MC707VM-W/S
Model
Power supply
Dimensions
Colour
Weight

HxWxD

MC707VM-S
1~, 220-240/220-230V, 50/60Hz
533x425x213
Sparkling silver + metallic ocean blue
8.7

mm
Kg

Mode (50Hz)
Power input
Sound pressure level
Sound power level
Air flow rate
Dust collecting method
Deodorising

kW
dB(A)
dB(A)
m3/h
Method
Deodorising performance (%)
Regenerate method

Bacteria filtering method


Filter

new

Turbo
0.055
47
62
420

Dust
collection and
deodorisation

Form
Function
Lifetime
Bio-Antibody filter
Pre-filter

H
M
L
0.023
0.014
0.010
38
31
24
52
40
39
285
180
120
Plasma ionizer (electrostatic dust collection) + Electrostatic dust collection filter
Flash Streamer + Titanium apatite photocatalytic filter + Deodorising catalyst
95
The Flash Streamer activates the photocatalytic reaction
Bio-Antibody filter + Flash Streamer + Titanium apatite photocatalytic filter
Pleated filter
Deodorisation + disinfection + dust collection + adjuvant removal
1 filter/1 year
New
Catechin pre-filter

Silent
0.008
16
31
60

Flash Streamer unit

Flash Streamer
High-speed electrons are
generated by the Flash
Streamer. These electrons
powerfully break down
odours and formaldehyde.

Electrostatic dust
collection filter
Positively charged dust and
pollen are adsorbed by the
negatively charged filter.
Front

Deodorising catalyst
Odours are adsorbed
and broken down
before the air is
returned into the room.

Purified air
Back
Titanium Apatite
Photocatalytic Filter
Odour, bacteria and viruses are
adsorbed and decomposed.

1571 UK Intro_pp1-9.indd 9

24/7/07 12:12:05

Daikin residential air conditioning is the modern, economic and efficient way to switch on to springtime - in the living
room, dining room, kitchen or bedroom, night and day, throughout the year.
Daikin air conditioning units are the preferred unit by professional engineers, easy to use, ultra reliable, quiet running and
come in an elegant and up to date range of wall, floor and ceiling mounted indoor models.
Also, the incorporation of inverter control enables Daikin to bring air conditioning technology of the future to the
residential market today. Inverter control cuts start up time and energy consumption by almost a third, alters unit output
to suit outdoor conditions, improves performance relative to power input, ensures a more even room temperature and
eliminates power surges and stop/start cycles.

Residential & Commercial


1. Wall mounted units
FTXR-E / RXR-E
FTXG-E / RXG-E
FTKS-DW / RKS-E
FTXS-DW / RXS-E
FTKS-DL / RKS-E
FTXS-DL / RXS-E
FTXS-C / RX-E
FTKS-F / RKS-F
FTXS-F / RXS-F
FAQ-B / RZQS-B
FAQ-B / RZQ-B/C
2. Flexi type units
FLKS-B / RKS-E
FLKS-B / RKS-F
FLXS-B / RXS-E
FLXS-B / RXS-F
3. Floor standing units
FVXS-F / RKS-F
FVXS-F / RXS-F
4. Concealed ceiling units
FDKS-E / RKS-E
FDKS-C / RKS-F
FDXS-E / RXS-E
FDXS-C / RXS-F
FBQ-B / RKS-E
FBQ-B / RKS-F
FBQ-B / RXS-E
FBQ-B / RXS-F
FBQ-B/ REQ-B
FBQ-B / RZQS-B/C
FBQ-B / RZQ-B/C
FDQ-B / RZQS-C
FDQ-B / RZQ-B/C

12
14
15
16
17
18
19
20
21
22
23
24
25
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43

5. Cassette units
FFQ-B / RKS-E
FFQ-B / RKS-F
FFQ-B / RXS-E
FFQ-B / RXS-F
FCQ-C / RKS-E
FCQ-C / RKS-F
FCQ-C / RXS-E
FCQ-C / RXS-F
FCQ-C / REQ-B
FCQ-C / RZQS-B/C
FCQ-C / RZQ-B/C
FCQH-C / RZQS-B/C
FCQH-C / RZQ-B/C
6. 4-Way blow ceiling suspended cassettes
FUQ-B / RZQ-B/C
7. Ceiling suspended units
FHQ-B / RKS-E
FHQ-B / RKS-F
FHQ-B / RXS-E
FHQ-B / RXS-F
FHQ-B / REQ-B
FHQ-B / RZQS-B/C
FHQ-B / RZQ-B/C
TWIN/TRIPLE/DOUBLE TWIN APPLICATIONS
Possible combinations
RZQS
RZQ
MULTI MODEL APPLICATION
MKS-E/F
MXS-E/F
RMXS-E
Altherma
AIR HANDLING UNIT CONNECTIONS
ERX

10

45
46
47
48
50
51
52
53
54
55
56
57
58
59
61
62
63
64
65
66
67
69
70
72
74
77
81
85
89

Good Design Award

1. URURU
HUMIDIFICATION:

Humidified air feels warmer

All the moisture in the outdoor air


available inside
The Ururu humidification subsystem
uses a special built-in humidification
element in the outdoor unit to absorb
the moisture present in the outdoor
air and send it to the indoor unit.
Since moisture is not absorbed from
the rooms air, quick and effective
humidification is possible even with
the drier air of winter.

Dry air actually makes your body feel


cooler. Ururu humidification at mod
erate levels and a relatively low tem
perature will probably leave you feeling
warmer. This also prevents dry skin and
sore throats, and maintains a humidity
level in which viruses cannot survive.

Moisture
particles

Room temperature 28C


Humidity 20%

Room temperature 22C


Humidity 50%

Ururu
humidification
operation

COLD
You feel cold in dry air
even at high temperature.

WARM
You feel comfortable
warmer in humidified air.

2. SARARA
DEHUMIDIFICATION:
Moisture is extracted from
the outdoor air
Humidification unit

Fully humidified air is


delivered to the room.

Ururu humidification evenly heats


the entire room.
The unit incorporates both an air
conditioner and a humidifier, making
ideal heating possible. The Ururu humid
ification subsystem
effectively
supplies
the 450ml/h of water
required
to fully
humidify an entire
large living room.

Ururu Sarara reduces indoor humidity


without affecting the room temper
ature, by mixing dry cool air with
warm air to produce comfortable
dry air (Sarara Drying Operation, also
called reheating dehumidification).
This feature prevents overcooling,
which is particularly appreciated by
people who are sensitive to cold. If
the indoor temperature becomes too
high, Ururu Sarara reduces humidity
level by reducing also temperature
(cooling dehumidification).
Lower humidity creates com
fortable dryness, even at a constant
temperature

while maintaining the same room


temperature. This feature prevents
overcooling, which is especially good
for people who are sensitive to cold.

Room temperature 25C


Humidity 80%

Room temperature 25C


Humidity 50%

Sarara
dehumidification
operation

OVERHEATED
COMFORTABLEDRY
Hot and stuffy with high Decreasing humidity while
humidity.
maintaining the temperature
increases comfort.

3. OTHER FEATURES:
Powerful ventailation
Powerful air purification with
Daikin flash streamer technology
Energy efficient: A class energy
label
Comfortable air flow
Moisturizing operation mode
Breeze cooling air flow
Comfort sleep operation
Mould shock operation

Decreasing the level of humidity will


increase your feeling of comfort, even

Note: Humidification and dehumidification operations can be used under specific indoor and outdoor temperature and humidity conditions
(similar to cooling and heating operation range). Please refer to the technical databooks for more details.

11

FTXR-E / RXR-E
Wall mounted unit

ARC 447AI
l
l

l
l
l
l
l
l

FTXR 28,42,50E

URURU humidification: maintains a comfortable


humidity level without any separate water supply
SARARA dehumidification: maintains a comfortable
and fresh indoor environment by removing moisture
from the air without lowering the temperature
Energy efficient: full range A class labels (EER =
5.00/COP = 5.14)
Powerful ventilation: refreshes the room within 2
hours
Powerful air purification: increases indoor air quality
with Daikin Flash Streamer technology
Comfortable air flow
Stylish design
Other features: moisturizing operation mode, breeze
cooling air flow, comfort sleep operation, mould
shock operation

RXR 28,42,50E

(5 steps)

(standard)

(integrated
titanium apatite)

(optional)

Heat Pump
Indoor Units
Nominal Capacity

INVERTER
FTXR28EV1B9

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum

Annual energy consumption


EER / COP
Cooling / Heating
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Heating
H/M/L/SL
Sound Power
Cooling
Medium
Heating
Medium
Sound Pressure
Cooling
H/M/L/SL
Heating
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

kW
kW
kW
kW
kW
kW
kWh

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

FTXR42EV1B9
1.55
4.2
4.60
1.30
5.1
5.6
525
4.00 / 4.32
A/A
209x890x305
14
12.4 / 9.6 / 6.8 / 6.0
12.9 / 10.2 / 7.7 / 6.8
58
58
42 / 35 / 27 / 24
42 / 36 / 29 / 26
R-410A
1~/220-240V/50Hz

2.8
3.6
3.6
5.00
280
5.00 / 5.14

11.1 / 8.8 / 6.5 / 5.7


12.4 / 9.8 / 7.3 / 6.5
55
57
39 / 33 / 26 / 23
41 / 35 / 28 / 25

RXR28EV1B9
(Height x Width x Depth)
Cooling
Heating
Cooling
Cooling
Heating

H/L
H/L
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)

mm
kg
dBA
dBA
dBA
CDB
CWB
Type

RXR42EV1B9
693x795x285
48
48
48
62
-10~43
-20~18
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
10

46
46
60

mm
m

12

FTXR50EV1B9
5.0
5.50
6.0
6.20
730
3.42 / 3.97

13.3 / 10.3 / 7.3 / 6.5


14.0 / 11.1 / 8.3 / 7.3
60
60
44 / 37 / 29 / 26
44 / 38 / 31 / 28

RXR50EV1B9

48
50
62

UX1
1. STYLISH AND COMPACT
DESIGN

40%
UP

40%
UP

EER/COP

while during heating operation it turns


downward vertically to send the warm
air directly to the feet.

4.15

4.03

For this model, Daikin even received


the Good Design Award in Japan.

2. SENSATIONAL THINNING
TECHNOLOGY

25% size reduction

High efciency
exchanger:

FTXG

slit

1.00

Cooling

NEW

NEW

2.00

3-D Air ow:

Heating

FTXG25
FTYN25

These top of the class values are achieved


by the following 3 technologies:
PAM Inverter control
Reluctance DC motor + DC Fan motor
Swing compressor

4. CLEAN AND
COMFORTABLE AIR FLOW

Good Design Award

FTK(X)S

3.00
Conventional

Daikin succeeded in creating an indoor


unit with such a sleek prole, that you
wont believe it is an air conditioning unit.
In standby mode, the discharge
opening is closed, resulting in a
compact depth of only 15cm.
When starting the unit up, the entire
front panel slides smoothly open.

Conventional

4.00

heat

Miniature cross ow fan


The blade conguration has been
optimized to achieve quiet operation
and powerful air ow, while reducing
the fans diameter by 20% compared
to conventional models.

3. SUPERB ENERGY EFFICIENCY


Daikin has further improved the energy
efciency. At the same time it realized
substantial energy savings compared
to conventional models by achieving
an industrial top class EER of 4.03 and
COP of 4.15.

For the rst time in history, a titanium


apatite photocatalytic air purication
lter is integrated in an air conditioning
unit. This increases the active surface
area for effective purication and
deodorisation, even when a high
volume of air is required.
Super quiet:
The indoor/outdoor unit silent operation
function brings us comfort by offering
an industry top-level quiet operation
of 22dB(A) for the indoor unit and
43dB(A) for the outdoor unit.
Comfort mode:
The new wide-angle distribution ap
reassures draught free operation.
During cooling operation the ap
angle turns horizontally to prevent
cold air blowing directly on the body,

Cooling mode

Heating mode

13

This function combines Vertical and


Horizontal auto-swing to circulate a
stream of cool/warm air right to the
corners of even large spaces.

FTXG-E / RXG-E
Wall mounted unit

ARC 433A41
l
l
l
l
l
l
l
l

l
l
l

FTXG 25,35E-S

FTXG 25,35E-W

RXG25,35E

State of the art design: sleek, compact and stylish


outlook
Available in 2 colour variations: matt crystal white
and matt crystal silver
Lightweight and compact
Easy to clean flat suction grille
Superb energy efficiency
Movement sensor saves power consumption in
unoccupied rooms
Comfort mode for draught free operation thanks to
the new wide angle distribution flap
The new titanium apatite photocatalytic air
purification filter increases the active surface area for
effective purification and deodorisation
Horizontal and vertical auto-swing 3D-air flow
ensure efficient air and temperature distribution.
Powerful mode can be selected for rapid cooling or
heating
Indoor / outdoor unit silent operation

(5 steps)

(standard)

(integrated
titanium apatite)

MXS

Heat Pump
Indoor Units
Nominal Capacity

INVERTER
FTXG25EV1BW

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum

Annual energy consumption


EER / COP
Cooling / Heating
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Heating
H/M/L/SL
Sound Power
Cooling
High
Heating
High
Sound Pressure
Cooling
H/M/L/SL
Heating
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

kW
kW
kW
kW
kW
kW
kWh

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

FTXG25EV1BS

FTXG35EV1BW

1.3
2.5
3.0
1.3
3.4
4.5
310
4.03 / 4.15

H
H
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

mm
kg
dBA
dBA
dBA
CDB
CWB
Type

FTXG35EV1BS
1.4
3.5
3.8
1.4
4.2
5.0
530
3.30 / 3.72

A/A
275x840x150
9.0
7.7 / 6.1 / 4.7 / 3.8
9.0 / 7.9 / 6.7 / 5.4
56.0
56.0
38.0 / 32.0 / 25.0 / 22.0
38.0 / 33.0 / 28.0 / 25.0

8.1 / 6.5 / 4.9 / 4.1


9.6 / 8.2 / 6.7 / 5.9
57.0
57.0
39.0 / 33.0 / 26.0 / 23.0
39.0 / 34.0 / 29.0 / 29.0
R-410A
1~/220-240V/50Hz

RXG25E2V1B
(Height x Width x Depth)
Cooling
Heating
Cooling
Cooling
Heating

(optional)

RXG35E2V1B
550x765x285
32

46
47
61

47
48
62
10.0~46.0

-15.0~20.0

-15~20
R-410A
1~/230V/50Hz
6.35 / 9.5 / 18
20
15.0

mm
m
m

14

FTKS-DW / RKS-E
Wall mounted unit

ARC433A43
l
l
l
l

l
l
l
l
l
l
l

l
l
l

FTKS20,25,35D3VMW

Flat front panel: its stylish appearance blends easily


within any interior dcor and is more easy to clean.
Lightweight and compact
Consumes up to 30% less energy than non-inverter
units
ECONO mode decreases power consumption so
that other appliances that need large power supply
can be used
Energy saving
Reaches set temperature more quickly
Home leave operation saves energy during absence
Movement sensor saves power consumption in
unoccupied rooms
Dual air discharge flow for better air distribution
Comfort mode for draught free operation
Titanium apatite photocatalytic air purification filter
absorbs microscopic particles, decomposes odours
and even deactivates bacteria and viruses
Powerful mode can be selected for rapid cooling
Indoor / outdoor unit silent operation
Night quiet mode (only in multi application and
cooling only mode)

5 steps

MKS

Cooling capacity Minimum


Standard
Maximum
Nominal

EER
Annual energy consumption
Energy Label
cooling
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Sound Power
Cooling
High
Sound Pressure
Cooling
H/L/SL
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Sound pressure level
H/L
Sound power level
H
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

standard

(integrated
titanium
apatite)

optional

Cooling only
Indoor Units
Nominal Capacity

RKS20,25,35E

INVERTER
kW
kW
kW
kWh
mm
kg
m/min
dBA
dBA
dBA
Type

mm
kg
dBA
dBA
CDB
Type
mm
m
m

FTKS20D3VMW
1.2
2.0
2.6
4.17
240
A
283x800x195
9.0
8.7 / 6.7 / 4.7 / 3.9
56.0
38.0 / 25.0 / 22.0
R-410A
1~/220-240/220-230V/50/60Hz

FTKS25D3VMW
1.2
2.5
3.0
4.17
300
A
283x800x195
9.0
8.7 / 6.7 / 4.7 / 3.9
56.0
38.0 / 25.0 / 22.0
R-410A
1~/220-240/220-230V/50/60Hz

FTKS35D3VMW
1.2
3.4
3.8
3.40
500
A
283x800x195
9.0
8.9 / 6.9 / 4.8 / 4.0
57.0
39.0 / 26.0 / 23.0
R-410A
1~/220-240/220-230V/50/60Hz

RKS20E2V1B
550x765x285
30
46 / 43
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

RKS25E2V1B
550x765x285
32
46 / 43
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

RKS35E2V1B
550x765x285
32
47 / 44
62
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

15

FTXS-DW / RXS-E
Wall mounted unit

ARC433A43
l

l
l
l

l
l
l
l
l

Flat front panel: its stylish appearance blends


easily within any interior dcor and is more
easy to clean.
Lightweight and compact
Consumes up to 30% less energy than noninverter units
ECONO mode decreases power consumption
so that other appliances that need large
power supply can be used
Energy saving
Reaches set temperature more quickly
Home leave operation saves energy during
absence
Movement sensor saves power consumption
in unoccupied rooms
Dual air discharge flow for better air
distribution

l
l

l
l
l

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum
Cooling / Heating

Sound power level


Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

MXS

5 steps

standard

optional

INVERTER

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Heating
H/M/L/SL
Sound Power
Cooling
High
Heating
High
Sound Pressure
Cooling
H/L/SL
H/M/L/SL
Heating
H/L/SL
H/M/L/S
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level

RXS20,25,35E

(integrated
titanium
apatite)

Heat Pump
Indoor Units
Nominal Capacity

FTXS20,25,35D3VMW

Comfort mode for draught free operation


Titanium apatite photocatalytic air purification
filter absorbs microscopic particles,
decomposes odours and even deactivates
bacteria and viruses
Powerful mode can be selected for rapid
cooling or heating
Indoor / outdoor unit silent operation
Night quiet mode (only in multi application
and cooling only mode)

H/L
H/L
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

kW
kW
kW
kW
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
dBA
dBA
Type

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FTXS20D3VMW
1.2
2.0
2.6
1.2
2.7
4.1
4.17 / 4.15
240
A/A
283x800x195
9.0
8.7 / 6.7 / 4.7 / 3.9
9.4 / 7.6 / 5.8 / 5.0
56.0
56.0
38.0 / 25.0 / 22.0
38.0 / 28.0 / 25.0
R-410A
1~/220-240/220-230V/50/60Hz

FTXS25D3VMW
1.2
2.5
3.0
1.2
3.4
4.5
4.17 / 4.10
300
A/A
283x800x195
9.0
8.7 / 6.7 / 4.7 / 3.9
9.4 / 7.6 / 5.8 / 5.0
56.0
56.0
38.0 / 25.0 / 22.0
38.0 / 28.0 / 25.0
R-410A
1~220-240/220-230V/50/60Hz

FTXS35D3VMW
1.2
3.4
3.8
1.2
4.0
5.0
3.40 / 3.70
500
A/A
283x800x195
9.0
8.9 / 6.9 / 4.8 / 4.0
9.7 / 7.9 / 6.0 / 5.2
57.0
57.0
39.0 / 26.0 / 23.0
39.0 / 29.0 / 26.0
R-410A
1~220-240/220-230V/50/60Hz

RXS20E2V1B
550x765x285
30
46 / 43
47 / 44
61
-10~46
-15~20
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

RXS25E2V1B
550x765x285
32
46 / 43
47 / 44
61
-10~46
-15~20
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

RXS35E2V1B
550x765x285
32
47 / 44
48 / 45
62
-10~46
-15~20
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

16

FTKS-DL / RKS-E
Wall mounted unit

ARC433A43
l
l
l
l

l
l
l
l
l
l
l

l
l
l

FTKS20,25,35D3VML

Flat front panel: its stylish appearance blends easily


within any interior dcor and is more easy to clean.
Lightweight and compact
Consumes up to 30% less energy than non-inverter
units
ECONO mode decreases power consumption so
that other appliances that need large power supply
can be used
Energy saving
Reaches set temperature more quickly
Home leave operation saves energy during absence
Movement sensor saves power consumption in
unoccupied rooms
Dual air discharge flow for better air distribution
Comfort mode for draught free operation
Titanium apatite photocatalytic air purification filter
absorbs microscopic particles, decomposes odours
and even deactivates bacteria and viruses
Powerful mode can be selected for rapid cooling
Indoor / outdoor unit silent operation
Night quiet mode (only in multi application and
cooling only mode)

5 steps

MKS

Cooling capacity Minimum


Standard
Maximum
Nominal

EER
Annual energy consumption
Energy Label
cooling
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Sound Power
Cooling
High
Sound Pressure
Cooling
H/L/SL
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Sound pressure level
H/L
Sound power level
H
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

standard

(integrated
titanium
apatite)

optional

Cooling only
Indoor Units
Nominal Capacity

RKS20,25,35E

INVERTER
kW
kW
kW
kWh
mm
kg
m/min
dBA
dBA
dBA
Type

mm
kg
dBA
dBA
CDB
Type
mm
m
m

FTKS20D3VML
1.2
2.0
2.6
4.17
240
A
283x800x195
9.0
8.7 / 6.7 / 4.7 / 3.9
56.0
38.0 / 25.0 / 22.0
R-410A
1~/220-240/220-230V/50/60Hz

FTKS25D3VML
1.2
2.5
3.0
4.17
300
A
283x800x195
9.0
8.7 / 6.7 / 4.7 / 3.9
56.0
38.0 / 25.0 / 22.0
R-410A
1~/220-240/220-230V/50/60Hz

FTKS35D3VML
1.2
3.4
3.8
3.40
500
A
283x800x195
9.0
8.9 / 6.9 / 4.8 / 4.0
57.0
39.0 / 26.0 / 23.0
R-410A
1~/220-240/220-230V/50/60Hz

RKS20E2V1B
550x765x285
30
46 / 43
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

RKS25E2V1B
550x765x285
32
46 / 43
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

RKS35E2V1B
550x765x285
32
47 / 44
62
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

17

FTXS-DL / RXS-E
Wall mounted unit

ARC433A43
l

l
l
l

l
l
l
l
l

Flat front panel: its stylish appearance blends


easily within any interior dcor and is more
easy to clean.
Lightweight and compact
Consumes up to 30% less energy than noninverter units
ECONO mode decreases power consumption
so that other appliances that need large
power supply can be used
Energy saving
Reaches set temperature more quickly
Home leave operation saves energy during
absence
Movement sensor saves power consumption
in unoccupied rooms
Dual air discharge flow for better air
distribution

l
l

l
l
l

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum
Cooling / Heating

Sound power level


Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

MXS

5 steps

standard

optional

INVERTER

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Heating
H/M/L/SL
Sound Power
Cooling
High
Heating
High
Sound Pressure
Cooling
H/L/SL
H/M/L/SL
Heating
H/L/SL
H/M/L/S
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level

RXS20,25,35E

(integrated
titanium
apatite)

Heat Pump
Indoor Units
Nominal Capacity

FTXS20,25,35D3VML

Comfort mode for draught free operation


Titanium apatite photocatalytic air purification
filter absorbs microscopic particles,
decomposes odours and even deactivates
bacteria and viruses
Powerful mode can be selected for rapid
cooling or heating
Indoor / outdoor unit silent operation
Night quiet mode (only in multi application
and cooling only mode)

H/L
H/L
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

kW
kW
kW
kW
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
dBA
dBA
Type

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FTXS20D3VML
1.2
2.0
2.6
1.2
2.7
4.1
4.17 / 4.15
240
A/A
283x800x195
9.0
8.7 / 6.7 / 4.7 / 3.9
9.4 / 7.6 / 5.8 / 5.0
56.0
56.0
38.0 / 25.0 / 22.0
38.0 / 28.0 / 25.0
R-410A
1~/220-240/220-230V/50/60Hz

FTXS25D3VML
1.2
2.5
3.0
1.2
3.4
4.5
4.17 / 4.10
300
A/A
283x800x195
9.0
8.7 / 6.7 / 4.7 / 3.9
9.4 / 7.6 / 5.8 / 5.0
56.0
56.0
38.0 / 25.0 / 22.0
38.0 / 28.0 / 25.0
R-410A
1~220-240/220-230V/50/60Hz

FTXS35D3VML
1.2
3.4
3.8
1.2
4.0
5.0
3.40 / 3.70
500
A/A
283x800x195
9.0
8.9 / 6.9 / 4.8 / 4.0
9.7 / 7.9 / 6.0 / 5.2
57.0
57.0
39.0 / 26.0 / 23.0
39.0 / 29.0 / 26.0
R-410A
1~220-240/220-230V/50/60Hz

RXS20E2V1B
550x765x285
30
46 / 43
47 / 44
61
-10~46
-15~20
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

RXS25E2V1B
550x765x285
32
46 / 43
47 / 44
61
-10~46
-15~20
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

RXS35E2V1B
550x765x285
32
47 / 44
48 / 45
62
-10~46
-15~20
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

18

FTXS-C / RX-E
Wall mounted unit

ARC 433AR
l
l
l
l
l
l
l
l
l
l
l

FTXS 20,25,35C

Flat front panel: its stylish appearance blends easily


within any interior dcor and is more easy to clean.
Lightweight and compact
Consumes up to 30% less energy than non-inverter
units
Reaches set temperature more quickly
Home leave operation saves energy during absence
Movement sensor saves power consumption in
unoccupied rooms
Dual air discharge flow for better air distribution
Air purification filter with photocatalytic deodorising
function
Powerful mode can be selected for rapid cooling or
heating
Indoor unit silent operation
Night quiet mode (only in multi application and
cooling only mode)

RX 20,25,35E

(5 steps)

(standard)

MXS

Heat Pump
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum

Annual energy consumption


EER / COP
Cooling / Heating
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Heating
H/M/L/SL
Sound Power
Cooling
High
Heating
High
Sound Pressure
Cooling
H/M/L/SL
Heating
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

kW
kW
kW
kW
kW
kW
kWh

FTXS20CAVMB
1.2
2.0
2.6
1.2
2.7
4.1
290
3.45 / 3.80
A/A

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

FTXS25CAVMB
1.2
2.5
3.00
1.2
3.4
4.5
385
3.25 / 3.62
A/A
273x784x195
7.5
7.70 / 5.90 / 4.20 / 3.60
7.80 / 6.50 / 5.30 / 4.60
56.0
56.0
38.0 / 32.0 / 25.0 / 22.0
38.0 / 33.0 / 28.0 / 25.0

H
H
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

mm
kg
dBA
dBA
dBA
CDB
CWB
Type

FTXS35CAVMB
1.2
3.4
3.8
1.2
3.7
5.0
530
3.21 / 3.63
A/A

7.70 / 6.00 / 4.40 / 3.80


8.10 / 6.70 / 5.30 / 4.60
57.0
57.0
39.0 / 33.0 / 26.0 / 23.0
39.0 / 34.0 / 29.0 / 26.0

R-410A
1~/220-240/220-230V/50/60Hz

RX20E2V1B
(Height x Width x Depth)
Cooling
Heating
Cooling
Cooling
Heating

(optional)

RX25E2V1B
550x765x285
30
46
47
61
10.0~46.0
-10~20
R-410A
1~/220-240/220-230V/50Hz
6.35 / 9.5 / 18
15
10.0

30
46
47
61

mm
m
m

19

RX35E2V1B
32
47
48
62

FTKS-F / RKS-F
Wall mounted Unit

ARC433A70
l
l
l
l
l
l
l
l

FTKS50,60,71F

Flat front panel: its stylish appearance blends easily


within any interior dcor and is more easy to clean.
Lightweight and compact
Home leave operation saves energy during absence
Movement sensor saves power consumption in
unoccupied rooms
Dual air discharge flow for better air distribution
Titanium apatite photocatalytic air purification filter
Indoor / outdoor unit silent operation
Night quiet mode (only in multi application and
cooling only mode)

RKS50,60,71F

optional

5 steps

standard

MKS

(integrated
titanium apatite)

Cooling only
Indoor Units
Nominal Capacity

Cooling capacity Minimum


Standard
Maximum
Nominal

EER
Annual energy consumption
Energy Label
cooling
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Sound Power
Cooling
Medium
Sound Pressure
Cooling
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Sound pressure level
H/SL
Sound power level
H
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

INVERTER
kW
kW
kW
kWh
mm
kg
m/min
dBA
dBA
Type

mm
kg
dBA
dBA
CDB
Type
mm
m
m

FTKS50FV1B
1.7
5.0
6.0
3.23
775
A
290x1050x238
12
14.7 / 12.4 / 10.3 / 9.5
59
43 / 39 / 34 / 31
R-410A
1~/220-240V/50Hz

FTKS60FV1B
1.7
6.0
6.7
3.02
995
B
290x1050x238
12
16.2 / 13.6 / 11.4 / 10.2
61
45 / 41 / 36 / 33
R-410A
1~/220-240V/50Hz

FTKS71FV1B
2.3
7.1
8.5
3.02
1175
B
290x1050x238
12
17.4 / 14.6 / 11.6 / 10.6
62
46 / 42 / 37 / 34
R-410A
1~/220-240V/50Hz

RKS50F2V1B
735x825x300
48
47 / 44
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30
20

RKS60F2V1B
735x825x300
47
49 / 46
63
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 18
30
20

RKS71FV1B
770x900x320
71
52 / 49
66
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 15.9 / 18
30
20

20

FTXS-F / RXS-F
Wall Mounted Unit

ARC433A70
l

l
l
l
l
l
l
l

FTXS50,60,71F

Flat front panel: its stylish appearance blends


easily within any interior dcor and is more
easy to clean.
Lightweight and compact
Home leave operation saves energy during
absence
Movement sensor saves power consumption
in unoccupied rooms
Dual air discharge flow for better air
distribution
Titanium apatite photocatalytic air purification
filter
Indoor / outdoor unit silent operation
Night quiet mode (only in multi application
and cooling only mode)

RXS50,60,71F

optional

5 steps

standard

MXS

(integrated
titanium apatite)

Heat Pump
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Heating
H/M/L/SL
Sound Power
Cooling
Medium
Heating
Medium
Sound Pressure
Cooling
H/M/L/SL
Heating
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

H/SL
H/SL
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

kW
kW
kW
kW
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FTXS50FV1B
1.7
5.0
6.0
1.7
5.8
7.7
3.23 / 3.63
775
A/A
290x1050x238
12
14.7 / 12.4 / 10.3 / 9.5
16.1 / 13.9 / 11.5 / 10.2
59
58
43 / 39 / 34 / 31
42 / 38 / 33 / 30
R-410A
1~/220-240V/50Hz

FTXS60FV1B
1.7
6.0
6.7
1.7
7.0
8.0
3.02 / 3.43
995
B/B
290x1050x238
12
16.2 / 13.6 / 11.4 / 10.2
17.4 / 15.1 / 12.7 / 11.4
61
60
45 / 41 / 36 / 33
44 / 40 / 35 / 32
R-410A
1~/220-240V/50Hz

FTXS71FV1BA
2.3
7.1
8.5
2.3
8.2
10.2
3.02 / 3.22
1175
B/C
290x1050x238
12
17.4 / 14.6 / 11.6 / 10.6
19.7 / 16.9 / 14.3 / 12.7
62
62
46 / 42 / 37 / 34
46 / 42 / 37 / 34
R-410A
1~/220-240V/50Hz

RXS50F2V1B
735x825x300
48
47 / 44
48 / 44
61
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30
20

RXS60F2V1B
735x825x300
48
49 / 46
49 / 46
63
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 18
30
20

RXS71FV1B
770x900x320
71
52-49
52-49
66
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 15.9 / 18
30
20

21

FAQ-B / RZQS-B
Wall Mounted Unit

BRC1D52 BRC7E618/C510
l
l

l
l
l

FAQ71,100B

Fits neatly on a wall


Ideal for shops, restaurants or offices
requiring maximum floor space for
furniture, decorations and fittings
Auto-swing function ensures efficient
air distribution via louvers that close
automatically when the unit is
switched off
Automatic movable louver can be
fixed at any desired angle
Both horizontal flaps and front panel
can easily be removed and washed
All maintenance operations can be
carried out from the front of the unit

heat pump

Cooling capacity Standard


Heating capacity Standard
Cooling / Heating

optional

optional

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High/Low
Heating
High/Low
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Operation Range
Sound pressure level

(Height x Width x Depth)


Cooling
Min~Max
Heating
Min~Max
Cooling (night quiet mode)
Heating
Cooling

Sound power level


Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

INVERTER
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

mm
kg
CDB
CWB
dBA
dBA
dBA
Type
mm
m
m

optional

2 steps

Heat Pump
Indoor Units
Nominal Capacity

RZQS71,100B

FAQ71BVV1B
7.10
8.00
2.81 / 3.01
1265
C/D
290x1050x230
13.0
19.0 / 15.0
19.0 / 15.0
59.0 / 53.0
59.0 / 53.0
43.0 / 37.0
43.0 / 37.0
R-410A
1~/230V/50Hz

FAQ100BVV1B
10.00
11.20
2.45 / 3.00
2040
E/D
360x1570x200
26.0
23.0 / 19.0
23.0 / 19.0
61.0 / 57.0
61.0 / 57.0
45.0 / 41.0
45.0 / 41.0
R-410A
1~/230V/50Hz

RZQS71B7V3B
770x900x320
68
-5.0~46.0
-15.0~15.5
49 (43)
51
65
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
30
15

RZQS100B7V3B
770x900x320
68
-5.0~46.0
-15.0~15.5
51 (45)
55
67
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

22

FAQ-B / RZQ-B/C
Wall Mounted Unit

BRC1D52 BRC7E618/C510
l
l

l
l
l

FAQ71,100B

Fits neatly on a wall


Ideal for shops, restaurants or offices requiring
maximum floor space for furniture, decorations and
fittings
Auto-swing function ensures efficient air distribution
via louvers that close automatically when the unit is
switched off
Automatic movable louver can be fixed at any
desired angle
Both horizontal flaps and front panel can easily be
removed and washed
All maintenance operations can be carried out from
the front of the unit

RZQ100B

heat pump

optional

2 steps

optional

optional

Heat Pump
Indoor Units
Nominal Capacity

Cooling capacity Standard


Heating capacity Standard
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High/Low
Heating
High/Low
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling (Night quiet mode)
Heating
Cooling
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

INVERTER
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FAQ71BVV1B
7.1
8.0
3.01 / 3.31
1180
B/C
290x1050x230
13.0
19.0 / 15.0
19.0 / 15.0
59.0 / 53.0
59.0 / 53.0
43.0 / 37.0
43.0 / 37.0
R-410A
1~/230V/50Hz

FAQ100BVV1B
10.0
11.2
2.9 / 3.43
1725
C/B

3.60 / 3.30
1390
A/C
360x1570x200
26.0
23.0 / 19.0
23.0 / 19.0
61.0 / 57.0
61.0 / 57.0
45.0 / 41.0
45.0 / 41.0
R-410A
1~/230V/50Hz

RZQ71B9V3B1
770x900x320
68
47 (43)
49
63
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

RZQ100C7V1B
1170x900x320
103
49 (45)
51
65
-15~50.0
-20~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

23

RZQ100B8W1B
1345x900x320
106
49 (45)
51
65
-15.0~50.0
-20.0~15.5
R-410A
3~/400V/50Hz
9.52 / 15.9 / 26
75
30

FLKS-B / RKS-E
Flexi Type Unit

ARC433A6

l
l
l
l
l
l
l
l
l
l

FLKS25,35B

Can fit on either ceiling or lower wall. Its low height


enables it to fit beneath a window
Consumes up to 30% less energy than non-inverter
units
Washable front panel
Reaches set temperature more quickly
Auto-swing function ensures efficient air and
temperature distribution.
Home leave operation saves energy during absence
Air purification and photocatalytic deodorising filter
Powerful mode can be selected for rapid cooling
Indoor / outdoor unit silent operation
Night quiet mode (only in multi application and
cooling only mode)

Cooling capacity Minimum


Standard
Maximum
Nominal

EER
Annual energy consumption
Energy Label
cooling
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Sound Power
Cooling
High
Sound Pressure
Cooling
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Sound pressure level
H/L
Sound power level
H
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

RKS25,35E

optional

5 steps

standard

MKS

Cooling only
Indoor Units
Nominal Capacity

FLKS25,35B

INVERTER
kW
kW
kW
kWh
mm
kg
m/min
dBA
dBA
Type

mm
kg
dBA
dBA
CDB
Type
mm
m
m

FLKS25BAVMB
1.2
2.5
3.0
3.85
325
A
490x1050x200
16.0
7.60 / 6.80 / 6.00 / 5.2
53.0
37.0 / 34.0 / 31.0 / 28.0
R-410A
1~/220-240/220-230V/50/60Hz

FLKS35BAVMB
1.2
3.5
3.8
3.10
565
B
490x1050x200
16.0
8.60 / 7.60 / 6.6 / 5.6
54.0
38.0 / 35.0 / 32.0 / 29.0
R-410A
1~/220-240/220-230V/50/60Hz

RKS25E2V1B
550x765x285
32
46 / 43
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

RKS35E2V1B
550x765x285
32
47 / 44
62
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

24

FLKS-B / RKS-F
Flexi type unit

ARC433A6
l
l
l
l
l
l
l
l
l
l

FLKS50B

FLKS50B

Can fit on either ceiling or lower wall. Its low height


enables it to fit beneath a window
Consumes up to 30% less energy than non-inverter
units
Washable front panel
Reaches set temperature more quickly
Auto-swing function ensures efficient air and
temperature distribution.
Home leave operation saves energy during absence
Air purification and photocatalytic deodorising filter
Powerful mode can be selected for rapid cooling
Indoor / outdoor unit silent operation
Night quiet mode (only in multi application and
cooling only mode)

optional

5 steps

Cooling capacity Minimum


Standard
Maximum
Nominal

EER
Annual energy consumption
Energy Label
cooling
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Sound Power
Cooling
High
Sound Pressure
Cooling
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Sound pressure level
H/L
Sound power level
H
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

standard

MKS

Cooling only
Indoor Units
Nominal Capacity

RKS50F

INVERTER
FLKS50BAVMB
1.7
4.9
5.3
2.85
860
C
490x1050x200
17.0
11.40 / 10.00 / 8.50 / 7.5
63.0
47.0 / 43.0 / 39.0 / 36.0
R-410A
1~/220-240/220-230V/50/60Hz

kW
kW
kW
kWh
mm
kg
m/min
dBA
dBA
Type

RKS50F2V1B
735x825x300
48
47 / 44
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30
20

mm
kg
dBA
dBA
CDB
Type
mm
m
m

25

26

FLXS-B / RXS-E
Flexi type unit

ARC 433A6
l
l
l
l
l
l
l
l
l
l

FLXS 25,35B

FLXS 25,35B

Can fit on either ceiling or lower wall. Its low


height enables it to fit beneath a window
Consumes up to 30% less energy than noninverter units
Washable front panel
Reaches set temperature more quickly
Auto-swing function ensures efficient air and
temperature distribution.
Home leave operation saves energy during
absence
Air purification and photocatalytic deodorising
filter
Powerful mode can be selected for rapid
cooling or heating
Indoor / outdoor unit silent operation
Night quiet mode (only in multi application
and cooling only mode)

optional

5 steps

standard

Heat Pump
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum

Annual energy consumption


EER / COP
Cooling / Heating
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Heating
H/M/L/SL
Sound Power
Cooling
High
Heating
High
Sound Pressure
Cooling
H/M/L/SL
Heating
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

RXS 25,35E

H/L
H/L
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

kW
kW
kW
kW
kW
kW
kWh

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FLXS25BAVMB
1.2
2.5
3.0
1.2
3.4
4.5
325
3.85 / 3.47
A/B
490x1050x200
16.0
7.60 / 6.80 / 6.00 / 5.2
9.20 / 8.30 / 7.40 / 6.6
53.0
37.0 / 34.0 / 31.0 / 28.0
37.0 / 34.0 / 31.0 / 29.0
R-410A
1~/220-240/220-230V/50/60Hz

FLXS35BAVMB
1.2
3.5
3.8
1.4
4.0
5.0
565
3.10 / 3.25
B/C
490x1050x200
16.0
8.60 / 7.60 / 6.60 / 5.6
9.80 / 8.90 / 8.00 / 7.2
54.0
38.0 / 35.0 / 32.0 / 29.0
39.0 / 36.0 / 33.0 / 30.0
R-410A
1~/220-240/220-230V/50/60Hz

RXS25E2V1B
550x765x285
32
46 / 43
47 / 44
61
-10~46
-15~20
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

RXS35E2V1B
550x765x285
32
47 / 44
48 / 45
62
-10~46
-15~20
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

27

MXS

FLXS-B / RXS-F
Flexi type unit

ARC433A6
l
l
l
l
l
l
l
l
l
l

FLXS50B

FLXS50B

Can fit on either ceiling or lower wall. Its low


height enables it to fit beneath a window
Consumes up to 30% less energy than noninverter units
Washable front panel
Reaches set temperature more quickly
Auto-swing function ensures efficient air and
temperature distribution.
Home leave operation saves energy during
absence
Air purification and photocatalytic deodorising
filter
Powerful mode can be selected for rapid
cooling or heating
Indoor / outdoor unit silent operation
Night quiet mode (only in multi application and
cooling only mode)

optional

5 steps

standard

Heat Pump
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Heating
H/M/L/SL
Sound Power
Cooling
High
Heating
High
Sound Pressure
Cooling
H/M/L/SL
Heating
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

H/SL
H/SL
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

RXS50F

FLXS50BAVMB
1.7
4.9
5.3
1.7
6.1
7.5
2.85 / 3.35
860
C/C
490x1050x200
17.0
11.40 / 10.00 / 8.50 / 7.6
12.1 / 9.8 / 7.5 / 6.8
63.0
62.0
47.0 / 43.0 / 39.0 / 36.0
46.0 / 41.0 / 35.0 / 33.0
R-410A
1~/220-240/220-230V/50/60Hz

kW
kW
kW
kW
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

RXS50F2V1B
735x825x300
48
47 / 44
48 / 45
61
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30
20

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

28

MXS

FVXS-F / RKS-F
Floor Standing Unit

ARC452AI
l
l
l
l
l
l

RKS25,35F

FVXS25,35,50F

Stylish design
Flat front panel: its stylish appearance blends easily
within any interior dcor and is more easy to clean.
Titanium apatite photocatalytic air purification filter
Can be installed against a wall or recessed
Dual air discharge flow for better air distribution
ECONO mode decreases power consumption so
that other appliances that need large power supply
can be used
Lightweight but sturdy design

optional

5 steps

standard

Titanium apatite photocatalytic


air purification filter

Cooling only
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Minimum


Standard
Maximum
Nominal

EER
Annual energy consumption
Energy Label
cooling
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Sound Power
Cooling
High
Sound Pressure
Cooling
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range
Refrigerant
Power Supply

(Height x Width x Depth)


Cooling
Cooling
Cooling

H/L
H
Min~Max

Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

kW
kW
kW
kWh
mm
kg
m/min
dBA
dBA
Type

mm
kg
dBA
dBA
CDB
Type
mm
m
m

FVXS25FV1B
1.3
2.5
3.0
4.39
285
A
600x700x210
14
8.2 / 6.5 / 4.8 / 4.1
54
38 / 32 / 26 / 23
R-410A
1~/220-240V/50Hz

FVXS35FV1B
1.4
3.5
3.8
3.43
510
A
600x700x210
14
8.5 / 6.7 / 4.9 / 4.5
55
39 / 33 / 27 / 24
R-410A
1~/220-240V/50Hz

FVXS50FV1B
1.4
5.0
5.6
3.23
775
A
600x700x210
14
10.7 / 9.2 / 7.8 / 6.6
56
44 / 40 / 36 / 32
R-410A
1~/220-240V/50Hz

RKS25F2V1B
550x765x285
34
46 / 43
61
-10~46
R-410A
1~/220-240V/220-230V/50Hz
6.35 / 9.5 / 20
20
15

RKS35F2V1B
550x765x285
34
47 / 44
62
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 20
20
15

RKS50F2V1B
735x825x300
48
47 / 44
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30
20

29

FVXS-F / RXS-F
Floor standing unit

l
l
l
l
l
l

Stylish design
Flat front panel: its stylish appearance blends easily
within any interior dcor and is more easy to clean.
Titanium apatite photocatalytic air purification filter
Can be installed against a wall or recessed
Dual air discharge flow for better air distribution
ECONO mode decreases power consumption so
that other appliances that need large power supply
can be used
Lightweight but sturdy design

ARC452A1

FVXS 25,35,50F

RXS 25,35 F

optional

5 steps

standard

Titanium apatite photocatalytic


air purification filter

Heat Pump
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SO
Heating
H/M/L/SO
Sound Power
Cooling
High
Heating
High
Sound Pressure
Cooling
H/M/L/SO
Heating
H/M/L/SO
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

H/L
H/L
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping Connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

kW
kW
kW
kW
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FVXS25FV1B
1.3
2.5
3.0
1.3
3.4
4.5
4.39 / 4.30
285
A/A
600x700x210
14
8.2 / 6.5 / 4.8 / 4.1
8.8 / 6.9 / 5.0 / 4.4
54
54
38 / 32 / 26 / 23
38 / 32 / 26 / 23
R-410A
1~/220-240V/50Hz

FVXS35FV1B
1.4
3.5
3.8
1.4
4.5
5.0
3.43 / 3.69
510
A/A
600x700x210
14
8.5 / 6.7 / 4.9 / 4.5
9.4 / 7.3 / 5.2 / 4.7
55
55
39 / 33 / 27 / 24
39 / 33 / 27 / 24
R-410A
1~/220-240V/50Hz

FVXS50FV1B
1.4
5.0
5.6
1.4
5.8
8.1
3.23 / 3.63
775
A/A
600x700x210
14
10.7 / 9.2 / 7.8 / 6.6
11.8 / 10.1 / 8.5 / 7.1
56
57
44 / 40 / 36 / 32
45 / 40 / 36 / 32
R-410A
1~/220-240V/50Hz

RXS25F2V1B
550x765x285
34
46 / 43
47 / 44
61
-10~46
-15~20
R-410A
1~/220-240V/230-240V/50Hz
6.35 / 9.5 / 20
20
15

RXS35F2V1B
550x765x285
34
47 / 44
48 / 45
62
-10~46
-15~20
R-410A
1~/220-240V/230-240V/50Hz
6.35 / 9.5 / 20
20
15

RXS50F2V1B
735x825x300
48
47 / 44
48 / 45
61
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30
20

30

FDKS-E / RKS-E
Slim concealed ceiling unit

l
l
l
l
l
l
l
l
l

l
l

Slim design for flexible installation


Compact dimensions, can easily be mounted in a
ceiling void
Blends unobtrusively with any interior dcor
Can be installed in both new and existing buildings.
Leaves maximum floor and wall space for furniture,
decorations and fittings
Powerful mode can be selected for rapid cooling or
heating
Home leave operation saves energy during absence
Standard suction filter: removes airborne dust
particles to ensure a steady supply of clean air
Indoor / outdoor unit silent operation: "Silent"
buttons on the remote control lower the operation
sound of the indoor and/or outdoor unit by 3dB(A) .
Night quiet mode (only in multi application and
cooling only mode)
Medium external static pressure facilitates unit use
with flexible ducts of varying lengths

ARC433A8

Cooling capacity Minimum


Standard
Maximum
Nominal

EER
Energy label
Annual energy consumption
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Sound Power
Cooling
High
Sound Pressure
Cooling
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Sound pressure level
Cooling
H/L
Sound power level
Cooling
H
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

RKS25,35E

5 steps

standard

MKS

optional

Cooling only
Indoor Units
Nominal Capacity

FDKS25,35E

INVERTER
kW
kW
kW

kWh
mm
kg
m/min
dBA
dBA
Type

mm
kg
dBA
dBA
CDB
Type
mm
m
m

FDKS25EAVMB
1.3
2.4
3.0
3.48
A
345
200x700x620
21.0
8.7 / 8.0 / 7.3 / 6.2
53.0
35.0 / 33.0 / 31.0 / 29.0
R-410A
1~/220-240/220-230V/50/60Hz

FDKS35EAVMB
1.4
3.4
3.8
3.12
B
545
200x700x620
21.0
8.7 / 8.0 / 7.3 / 6.2
53.0
35.0 / 33.0 / 31.0 / 29.0
R-410A
1~/220-240/220-230V/50/60Hz

RKS25E2V1B
550x765x285
32
46 / 43
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

RKS35E2V1B
550x765x285
32
47 / 44
62
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

31

FDKS-C / RKS-F

Slim Concealed Ceiling Unit

ARC433A8
l
l
l
l
l
l
l
l
l

l
l

FDKS50,60C

Slim design for flexible installation


Compact dimensions, can easily be mounted in a
ceiling void
Blends unobtrusively with any interior dcor
Can be installed in both new and existing buildings.
Leaves maximum floor and wall space for furniture,
decorations and fittings
Powerful mode can be selected for rapid cooling or
heating
Home leave operation saves energy during absence
Standard suction filter: removes airborne dust
particles to ensure a steady supply of clean air
Indoor / outdoor unit silent operation: "Silent"
buttons on the remote control lower the operation
sound of the indoor and/or outdoor unit by 3dB(A) .
Night quiet mode (only in multi application and
cooling only mode)
Medium external static pressure facilitates unit use
with flexible ducts of varying lengths

MKS

5 steps

standard

optional

Cooling only
Indoor Units
Nominal Capacity

Cooling capacity Minimum


Standard
Maximum
Nominal

EER
Annual energy consumption
Energy Label
cooling
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Sound Power
Cooling
High
Sound Pressure
Cooling
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Sound pressure level
Cooling
H/SL
Sound power level
Cooling
H
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

RKS50,60F

INVERTER
kW
kW
kW
kWh
mm
kg
m/min
dBA
dBA
Type

mm
kg
dBA
dBA
CDB
Type
mm
m
m

FDKS50CVMB
1.7
5.0
5.3
3.03
825
B
200x900x620
27.0
12.0 / 11.0 / 10.0 / 8.4
55.0
37.0 / 35.0 / 33.0 / 31.0
R-410A
1~/220-240/220-230V/50/60Hz

FDKS60CVMB
1.7
6.0
6.5
2.82
1065
C
200x1100x620
30.0
16.0 / 14.8 / 13.5 / 11.2
56.0
38.0 / 36.0 / 34.0 / 32.0
R-410A
1~/220-240/220-230V/50/60Hz

RKS50F2V1B
735x825x300
48
47 / 44
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30
20

RKS60F2V1B
735x825x300
47
49 / 46
63
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 18
30
20

32

FDXS-E / RXS-E
Slim concealed ceiling unit

l
l
l
l
l
l
l
l
l

l
l

Slim design for flexible installation


Compact dimensions, can easily be mounted in a
ceiling void
Blends unobtrusively with any interior dcor
Can be installed in both new and existing buildings.
Leaves maximum floor and wall space for furniture,
decorations and fittings
Powerful mode can be selected for rapid cooling or
heating
Home leave operation saves energy during absence
Standard suction filter: removes airborne dust
particles to ensure a steady supply of clean air
Indoor / outdoor unit silent operation: "Silent"
buttons on the remote control lower the operation
sound of the indoor and/or outdoor unit by 3dB(A) .
Night quiet mode (only in multi application and
cooling only mode)
Medium external static pressure facilitates unit use
with flexible ducts of varying lengths

ARC433A8

standard

MXS

optional

INVERTER

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum

Annual energy consumption


EER / COP
Cooling / Heating
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Heating
H/M/L/SL
Sound Power
Cooling
High
Heating
High
Sound Pressure
Cooling
H/M/L/SL
Heating
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

RXS25,35E

5 steps

Heat Pump
Indoor Units
Nominal Capacity

FDXS25,35E

H/L
H/L
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

kW
kW
kW
kW
kW
kW
kWh

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FDXS25EAVMB
1.3
2.4
3.0
1.3
3.2
4.5
345
3.48 / 3.52
A/B
200x700x620
21.0
8.7 / 8.0 / 7.3 / 6.2
8.7 / 8.0 / 7.3 / 6.2
53.0
53.0
35.0 / 33.0 / 31.0 / 29.0
35.0 / 33.0 / 31.0 / 29.0
R-410A
1~/220-240/220-230V/50/60Hz

FDXS35EAVMB
1.4
3.4
3.8
1.4
4.0
5.0
545
3.12 / 3.39
B/C
200x700x620
21.0
8.7 / 8.0 / 7.3 / 6.2
8.7 / 8.0 / 7.3 / 6.2
53.0
53.0
35.0 / 33.0 / 31.0 / 29.0
35.0 / 33.0 / 31.0 / 29.0
R-410A
1~/220-240/220-230V/50/60Hz

RXS25E2V1B
550x765x285
32
46 / 43
47 / 44
61
-10~46
-15~20
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

RXS35E2V1B
550x765x285
32
47 / 44
48 / 45
62
-10~46
-15~20
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

33

FDXS-C / RXS-F

Slim Concealed Ceiling Unit

ARC433A8
l
l
l
l
l
l
l
l

Slim design for flexible installation


Compact dimensions, can easily be
mounted in a ceiling void
Blends unobtrusively with any interior
dcor
Can be installed in both new and
existing buildings.
Leaves maximum floor and wall space
for furniture, decorations and fittings
Powerful mode can be selected for
rapid cooling or heating
Home leave operation saves energy
during absence
Standard suction filter: removes
airborne dust particles to ensure a
steady supply of clean air

FDXS 50,60C

Indoor / outdoor unit silent operation:


"Silent" buttons on the remote control
lower the operation sound of the
indoor and/or outdoor unit by 3dB(A) .
l Night quiet mode (only in multi
application and cooling only mode)
l Medium external static pressure
facilitates unit use with flexible ducts
of varying lengths

RXS50,60F

optional

5 steps

standard

MXS

optional

Heat Pump
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
H/M/L/SL
Heating
H/M/L/SL
Sound Power
Cooling
High
Heating
High
Sound Pressure
Cooling
H/M/L/SL
Heating
H/M/L/SL
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

H/SL
H/SL
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

kW
kW
kW
kW
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FDXS50CVMB
1.7
5.0
5.3
1.7
5.8
6.0
3.03 / 3.02
825
B/D
200x900x620
27.0
12.0 / 11.0 / 10.0 / 8.4
12.0 / 11.0 / 10.0 / 8.4
55.0
55.0
37.0 / 35.0 / 33.0 / 31.0
37.0 / 35.0 / 33.0 / 31.0
R-410A
220-240/220-230V/50/60Hz

FDXS60CVMB
1.7
6.0
6.5
1.7
7.0
8.0
2.82 / 3.02
1065
C/D
200x1100x620
30.0
16.0 / 14.8 / 13.5 / 11.2
16.0 / 14.8 / 13.5 / 11.2
56.0
56.0
38.0 / 36.0 / 34.0 / 32.0
38.0 / 36.0 / 34.0 / 32.0
R-410A
220-240/220-230V/50/60Hz

RXS50F2V1B
735x825x300
48
47 / 44
48 / 45
61
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30
20

RXS60F2V1B
735x825x300
48
49 / 46
49 / 46
63
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 18
30
20

34

FBQ-B / RKS-E
Concealed ceiling unit

BRC1D52
l
l
l
l

l
l
l

FBQ35,50B

Lightweight and compact


Slim design for flexible installation
Blends unobtrusively with any interior dcor: only
the suction and discharge grilles are visible
The position of individual air discharge grilles can be
altered, enabling efficient temperature distribution,
even in irregularly shaped rooms.
Optimum air distribution
Quiet operation
Maximum external static pressure (ESP) is 88Pa

RKS35E

heat pump

standard

2 steps

35~60

Cooling only
Indoor Units
Nominal Capacity
Cooling capacity Standard
EER
Nominal
Energy label
Cooling
Annual energy consumption
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD
Weight

Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Sound pressure level
Cooling
H/L
Sound power level
Cooling
H
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

optional

INVERTER
FBQ35B8V1
3.4
2.91
C
585
300x700x800
30
11.5 / 9
52
33 / 29
R-410A
1~/230V/50Hz
BYBS45D
White
55x800x500
3.5

kW

kWh
mm
kg
m/min
dBA
dBA
Type

mm
kg

RKS35E2V1B
550x765x285
32
47 / 44
62
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

mm
kg
dBA
dBA
CDB
Type
mm
m
m

35

optional

FBQ-B / RKS-F
Concealed ceiling unit

BRC1D52
l
l
l
l

l
l
l

FBQ60B

Lightweight and compact


Slim design for flexible installation
Blends unobtrusively with any interior dcor: only
the suction and discharge grilles are visible
The position of individual air discharge grilles can be
altered, enabling efficient temperature distribution,
even in irregularly shaped rooms.
Optimum air distribution
Quiet operation
Maximum external static pressure (ESP) is 88Pa

RKS50,60F

heat pump

standard

2 steps

35~60

Cooling only
Indoor Units
Nominal Capacity
Cooling capacity Standard
EER
Nominal
Annual energy consumption
Energy Label
Cooling
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD
Weight

Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Sound pressure level
Cooling
H/L
Sound power level
Cooling
H
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

INVERTER
kW
kWh
mm
kg
m/min
dBA
dBA
Type

mm
kg

mm
kg
dBA
dBA
CDB
Type
mm
m
m

optional

FBQ50B8V1
5.0
2.60
960
E
300x700x800
31
14 / 10
53
33 / 29
R-410A
1~/230V/50Hz
BYBS45D
White
55x800x500
3.5

FBQ60B8V1
5.7
2.60
1095
E
300x1000x800
41
19 / 14
60
34 / 30
R-410A
1~/230V/50Hz
BYBS71D
White
55x1100x500
4.5

RKS50F2V1B
735x825x300
48
47 / 44
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30
20

RKS60F2V1B
735x825x300
48
49 / 46
63
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 18
30
20

36

optional

FBQ-B / RXS-E
Concealed ceiling unit

l
l
l
l

l
l
l

Lightweight and compact


Slim design for flexible installation
Blends unobtrusively with any interior dcor:
only the suction and discharge grilles are visible
The position of individual air discharge grilles
can be altered, enabling efficient temperature
distribution, even in irregularly shaped rooms.
Optimum air distribution
Quiet operation
Maximum external static pressure (ESP) is 88Pa

BRC1D52

RXS35E

FBQ35,50B

heat pump

standard

2 steps

35~60

Heat Pump
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Standard


Heating capacity Standard

Annual energy consumption


EER / COP
Cooling / Heating
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High
Heating
High
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD
Weight

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

H/L
H/L
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. inernunit level difference

optional

FBQ35B8V1
3.4
4.0
585
2.91 / 3.28
C/C
300x700x800
30
11.5 / 9
11.5 / 9
52
52
33 / 29
33 / 29
R-410A
1~/230V/50Hz
BYBS45D
White
55x800x500
3.5

kW
kW
kWh

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

mm
kg

RXS35E2V1B
550x765x285
32
47 / 44
48 / 45
62
-10~46
-15~20
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

37

optional

FBQ-B / RXS-F
Concealed ceiling unit

BRC1D52
l
l
l
l

l
l
l

FBQ60B

Lightweight and compact


Slim design for flexible installation
Blends unobtrusively with any interior dcor:
only the suction and discharge grilles are visible
The position of individual air discharge grilles
can be altered, enabling efficient temperature
distribution, even in irregularly shaped rooms.
Optimum air distribution
Quiet operation
Maximum external static pressure (ESP) is 88Pa

RXS50,60F

heat pump

standard

2 steps

35~60

Heat Pump
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Standard


Heating capacity Standard
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High
Heating
High
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD
Weight

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

H/SL
H/SL
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

mm
kg

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

optional

FBQ50B8V1
5.0
6.0
2.60 / 3.21
960
E/C
300x700x800
31
14 / 10
14 / 10
53
53
33 / 29
33 / 29
R-410A
1~/230V/50Hz
BYBS45D
White
55x800x500
3.5

FBQ60B8V1
5.7
7.0
2.60 / 2.80
1095
E/E
300x1000x800
41
19 / 14
19 / 14
60
60
34 / 30
34 / 30
R-410A
1~/230V/50Hz
BYBS71D
White
55x1100x500
4.5

RXS50F2V1B
735x825x300
48
47 / 44
48 / 45
61
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30
20

RXS60F2V1B
735x825x300
48
49 / 46
49 / 46
63
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 18
30
20

38

optional

FBQ-B / REQ-B
Concealed ceiling unit

FBQ100,125B

BRC1D52
l
l
l
l

l
l
l

Lightweight and compact


Slim design for flexible installation
Blends unobtrusively with any interior dcor: only
the suction and discharge grilles are visible
The position of individual air discharge grilles can be
altered, enabling efficient temperature distribution,
even in irregularly shaped rooms.
Optimum air distribution
Quiet operation
Maximum external static pressure (ESP) is 88Pa

heat pump

Cooling capacity Standard


Heating capacity Standard

Sound Power
Sound Pressure
Refrigerant
Power Supply
Decoration Panel

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

Cooling / Heating
Cooling / heating
(Height x Width x Depth)
Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High
High/Low
High/Low

Model
Colour
HxWxD
Weight

2 steps

kW
kW
kWh

FBQ71B8V3B
7.1
8

FBQ100B8V3B
10
11.2

FBQ125B8V3B
12.5
14.5
2335

1395

1340

1895

1800

2.54 / 3.21
E/C

2.65 / 3.21
D/C

2.64 / 2.86
D/D

2.78 / 2.89
D/D
300x1400x800

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

300x1000x800
41.0
19.00 / 14.00
19.00 / 14.00
60.0
34.0 / 30.0
34.0 / 30.0

2.61 / 3.21
D/C

51.0
27.00 / 20.00
27.00 / 20.00
62.0
36.0 / 31.0
36.0 / 31.0

52.0
35.00 / 24.00
35.00 / 24.00
63.0
38.0 / 32.0
38.0 / 32.0

R-410A
1~/230V/50Hz
BYBS71DJW1

BYBS125DJW1
White

mm
kg

55x1100x500
4.5

REQ71B8V3B
(Height x Width x Depth)
Cooling
Cooling
Cooling
Heating

optional

NON-INVERTER

Annual energy consumption


EER / COP
Energy Label
Dimensions
Weight
Air Flow Rate

optional

standard

Heat Pump
Indoor Units
Nominal Capacity

REQ125B

Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

mm
kg
dBA
dBA
CDB
CWB
Type

53
65

1~/230V/50Hz

55x1500x500
6.5

REQ71B8W1B
770x900x320
83
53
65

3N~/400V/50Hz

mm
m
m

39

REQ100B8V3B
102
57
70
10.0~46.0
-10~15
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

REQ100B8W1B
1170x900x320
100
57
70

REQ125B8W1B

3N~/400V/50Hz

108
57
70

FBQ-B / RZQS-B/C
Concealed ceiling unit

FBQ 100,125,140B

BRC1D52
l
l
l

l
l
l

Lightweight and compact


Slim design for flexible installation
Blends unobtrusively with any interior dcor:
only the suction and discharge grilles are
visible
The position of individual air discharge grilles
can be altered, enabling efficient temperature
distribution, even in irregularly shaped rooms.
Optimum air distribution
Quiet operation
Maximum external static pressure (ESP) is 88Pa

heat pump

standard

Cooling capacity Standard


Heating capacity Standard
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
Weight
HxWxD

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling (Night quiet mode)
Heating
Cooling
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

optional

optional

2 steps

Heat Pump
Indoor Units
Nominal Capacity

RZQS 125,140C

comfort INVERTER
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

kg
mm

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FBQ71B8V3B
7.1
8.0
2.82 / 3.33
1260
C/C
300x1000x800
41.0
19.00 / 14.00
19.00 / 60.0
34.0 / 30.0
34.0 / 30.0
R-410A
1~/230V/50Hz
BYBS71DJW1
White
4.5
55x1100x500

FBQ100B8V3B
10.0
11.2
2.61 / 3.23
1915
D/C
300x1400x800
51.0
27.00 / 20.00
27.00 / 20.00
62.0
36.0 / 31.0
36.0 / 31.0
R-410A
1~/230V/50Hz
BYBS125DJW1
White
6.5
55x1500x500

FBQ125B8V3B
12.5
14.0
2.84 / 3.30
2200
C/C
300x1400x800
52.0
35.00 / 24.00
35.00 / 24.00
63.0
38.0 / 32.0
38.0 / 32.0
R-410A
1~/230V/50Hz
BYBS125DJW1
White
6.5
55x1500x500

FBQ140B8V3B
13.4
15.5
2.81 / 3.21
2385
C/C
300x1400x800
52
35.00 / 24.00
35.00 / 24.00
63.0
38.0 / 32.0
38.0 / 32.0
R-410A
1~/230V/50Hz
BYBS125DJW1
White
6.5
55x1500x500

RZQS71B7V3B
770x900x320
68
49 (43)
51
65
-5.0~46.0
-15.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
30
15

RZQS100B7V3B
770x900x320
68
51 (45)
55
67
-5.0~46.0
-15.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

RZQS125C7V1
1170x900x320
103
51 (49)
53
67
-5~46
-15~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

RZQS140C7V1
1170x900x320
103
52 (50)
54
68
-5~46
-15~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

40

FBQ-B / RZQ-B/C
Concealed ceiling unit

FBQ100,125,140B

BRC1D52
l
l
l
l

l
l
l

Lightweight and compact


Slim design for flexible installation
Blends unobtrusively with any interior dcor: only
the suction and discharge grilles are visible
The position of individual air discharge grilles can be
altered, enabling efficient temperature distribution,
even in irregularly shaped rooms.
Optimum air distribution
Quiet operation
Maximum external static pressure (ESP) is 88Pa

RZQ100,125,140C

heat pump

standard

2 steps

35~60

Heat Pump
Indoor Units
Nominal Capacity

kW

Heating capacity Standard


EER / COP
Cooling / Heating
Annual energy consumption
Energy Label
Cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
Weight
HxWxD

kW

Sound power level


Operation Range

(Height x Width x Depth)


Cooling (Night quiet mode)
Heating
Cooling
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

optional

super INVERTER

Cooling capacity Standard

Outdoor Unit
Dimensions
Weight
Sound pressure level

optional

kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

kg
mm

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FBQ71B8V3B
7.1

FBQ100B8V3B
10.0
10.0

8.0
3.21 / 3.83
1105
A/A
300x1000x800
41.0
19.00 / 14.00
19 / 60.0
34.0 / 30.0
34.0 / 30.0
R-410A
1~/230V/50Hz
BYBS71DJW1
White
4.5
55x1500x500

11.2
3.33 / 3.75
1500

RZQ71B9V3B1
770x900x320
68
47 (43)
49
63
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

RZQ100C7V1B
1170x900x320
103
49 (45)
51
65
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

11.2
3.50 / 3.73
1430

A/A
300x1400x800
51.0
27.00 / 20.00
27.00 / 20.00
62.0
36.0 / 31.0
36.0 / 31.0
R-410A
1~/230V/50Hz
BYBS125DJW1
White
6.5
55x1500x500

41

RZQ100B8W1B
1345x900x320
106
49 (45)
51
65
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

FBQ125B8V3B
12.5
12.5

FBQ140B8V3B
13.4
13.4

14.0
14.0
3.14 / 3.52
3.14 / 3.51
1985
1990
B/B
B/B
300x1400x800
52.0
35.00 / 24.00
35.00 / 24.00
63.0
38.0 / 32.0
38.0 / 32.0
R-410A
1~/230V/50Hz
BYBS125DJW1
White
6.5
55x1500x500

15.5
15.5
2.81 / 3.21
2.82 / 3.21
2385
2380
C/C
C/C
300x1400x800
52.0
35.00 / 24.00
35.00 / 24.00
63.0
38.0 / 32.0
38.0 / 32.0
R-410A
1~/230V/50Hz
BYBS125DJW1
White
6.5
55x1500x500

RZQ125C7V1B
1170x900x320
103
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

RZQ125B8W1B
1345x900x320
106
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

RZQ140C7V1B
1170x900x320
103
50 (46)
52
67
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

RZQ140B8W1B
1345x900x320
106
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

FDQ-B / RZQS-C
Concealed ceiling unit

l
l
l
l
l

Slim design for flexible installation


Ideal for use in larger areas
Blends unobtrusively with any interior dcor: only
the suction and discharge grilles are visible
Maximum external static pressure (ESP) ranges from
150 till 250Pa
Optimum air distribution

BRC1D52

FDQ125B

RZQS125C

standard

3 steps: FDQ125

optional

Heat Pump
Indoor Units
Nominal Capacity

Cooling capacity Standard


Heating capacity Standard

Annual energy consumption


EER / COP
Cooling / Heating
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
Medium
Heating
Medium
Sound Power
Cooling
Medium
Sound Pressure
Cooling
High
Heating
Low
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling (Night quiet mode)
Heating
Cooling
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas
Piping Length (Maximum)
Max. internunit level difference

comfort INVERTER
FDQ125B8V3B
12.5
14.0
2225
2.81 / 3.43
C/B
350x1400x662
59.0
43.0
43.0
75.0
44.0
44.0
R-410A
1~/230V/50Hz

kW
kW
kWh

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

RZQS125C7V1
1170x900x320
103
51 (49)
53
67
-5~46
-15~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

42

optional

FDQ-B / RZQ-B/C
Concealed ceiling unit

l
l
l
l
l

BRC1D52

Slim design for flexible installation


Ideal for use in larger areas
Blends unobtrusively with any interior dcor: only
the suction and discharge grilles are visible
Maximum external static pressure (ESP) ranges from
150 till 250Pa
Optimum air distribution

FDQ200,250B

RZQ125B

standard

optional

2 steps: FDQ250, 3 steps:


FDQ125,200

optional

Heat Pump
Indoor Units
Nominal Capacity

Cooling capacity Standard


Heating capacity Standard
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
Medium
Heating
Medium
Sound Power
Cooling
Medium
Sound Pressure
Cooling
High
Heating
Low
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling (Night quiet mode)
Heating
Cooling
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas
Piping Length (Maximum)
Max. internunit level difference

super INVERTER
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FDQ125B8V3B
12.5
14.0
3.01 / 3.81
3.01 / 3.79
2075
B/A
350x1400x662
59.0
43.0
43.0
75.0
44.0
44.0
R-410A
1~/230V/50Hz

RZQ125C7V1B
1170x900x320
103
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
1~/220-240V/50Hz
9.52 / 15.9 / 26
75
30

RZQ125B8W1B
1345x900x320
106
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

43

FDQ200B8V3B
20.0
23.0
3.21 / 3.41
3115
A/B
450x1400x900
93.0
69.0
69.0
81.0
45.0
45.0
R-410A
1~/230V/50Hz

FDQ250B8V3B
24.1
26.4
2.81 / 3.21
4290
C/C
450x1400x900
93.0
89.0
89.0
82.0
47.0
47.0
R-410A
1~/230V/50Hz

RZQ200C7Y1B
1680x930x765
198
57 (-)
78
-5.0~46.0
-15.0~15.0
R-410A
3N~/380-415V/50Hz
9.5 / 22,2 / 100
30

RZQ250C7Y1B
1680x930x765
198
57 (-)
78
-5.0~46.0
-15.0~15.0
R-410A
3N~/380-415V/50Hz
12.7 / 22,2 / 100
30

44

FFQ-B / RKS-E

4-Way blow ceiling mounted cassette


(600mm x 600mm)

BRC7E531

BRC1D52
l

l
l
l

l
l
l

l
l
l

FFQ 25,35B

New and extremely compact casing (575mm


in width and depth) enables unit to fit flush
into ceilings and match standard architectural
modules, without cutting ceiling tiles
Modern style decoration panel in white
(RAL9010)
Slim design for flexible installation
Ideal for shops, restaurants or offices requiring
maximum floor space for furniture, decorations
and fittings
Extremely quiet in operation
Possibility to shut 1 or 2 flaps for easy
installation in corners
Auto-swing function ensures efficient air and
temperature distribution and prevents ceiling
soiling.
Excellent low draught characteristics
Easy installation and maintenance
The switch box can be reached by simply
removing the suction grille; therefore
maintenance can be done very easily.

heat pump

optional

Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Sound pressure level
H/L
Sound power level
H
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

standard

2 steps

optional

Cooling only
Indoor Units
Nominal Capacity
Cooling capacity Standard
EER
Nominal
Annual energy consumption
Energy Label
cooling
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD
Weight

RKS 25,35E

INVERTER
kW
kWh
mm
kg
m/min
dBA
dBA
Type

mm
kg

mm
kg
dBA
dBA
CDB
Type
mm
m
m

FFQ25B8V1B
2.5
3.42
365
A
286x575x575
17.5
9.0 / 6.5
46.5
29.5 / 24.5
R-410A
1~/230V/50Hz
BYFQ60BAW1
White(RAL 9010)
55x700x700
2.7

FFQ35B8V1B
3.4
3.09
550
B
286x575x575
17.5
10.0 / 6.5
49.0
32.0 / 25.0
R-410A
1~/230V/50Hz
BYFQ60BAW1
White(RAL 9010)
55x700x700
2.7

RKS25E2V1B
550x765x285
32
46 / 43
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

RKS35E2V1B
550x765x285
32
47 / 44
62
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

45

optional

FFQ-B / RKS-F

4-Way blow ceiling mounted cassette


(600mm x 600mm)

BRC1D52
l

l
l
l

l
l
l

l
l
l

BRC7E531

FFQ50,60B

New and extremely compact casing (575mm


in width and depth) enables unit to fit flush
into ceilings and match standard architectural
modules, without cutting ceiling tiles
Modern style decoration panel in white
(RAL9010)
Slim design for flexible installation
Ideal for shops, restaurants or offices requiring
maximum floor space for furniture, decorations
and fittings
Extremely quiet in operation
Possibility to shut 1 or 2 flaps for easy
installation in corners
Auto-swing function ensures efficient air and
temperature distribution and prevents ceiling
soiling.
Excellent low draught characteristics
Easy installation and maintenance
The switch box can be reached by simply
removing the suction grille; therefore
maintenance can be done very easily.

heat pump

optional

Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Sound pressure level
Cooling
H/L
Sound power level
Cooling
H
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

standard

2 steps

optional

Cooling only
Indoor Units
Nominal Capacity
Cooling capacity Standard
EER
Nominal
Annual energy consumption
Energy Label
cooling
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD
Weight

RKS50,60F

INVERTER
kW
kWh
mm
kg
m/min
dBA
dBA
Type

mm
kg

mm
kg
dBA
dBA
CDB
Type
mm
m
m

FFQ50B8V1B
4.7
2.61
900
D
286x575x575
17.5
12.0 / 8.0
53.0
36.0 / 27.0
R-410A
1~/230V/50Hz
BYFQ60BAW1
White(RAL 9010)
55x700x700
2.7

FFQ60B8V1B
5.8
2.80
1035
D
286x575x575
17.5
15.0 / 10.0
58.0
41.0 / 32.0
R-410A
1~/230V/50Hz
BYFQ60BAW1
White(RAL 9010)
55x700x700
2.7

RKS50F2V1B
735x825x300
48
47 / 44
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30
20

RKS60F2V1B
735x825x300
47
49 / 46
63
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 18
30
20

46

optional

FFQ-B / RXS-E

4-Way blow ceiling mounted cassette


(600mm x 600mm)

BRC1D52
l

l
l
l

l
l
l

l
l

New and extremely compact casing (575mm


in width and depth) enables unit to fit flush
into ceilings and match standard architectural
modules, without cutting ceiling tiles
Modern style decoration panel in white
(RAL9010)
Slim design for flexible installation
Ideal for shops, restaurants or offices requiring
maximum floor space for furniture, decorations
and fittings
Extremely quiet in operation
Possibility to shut 1 or 2 flaps for easy
installation in corners
Auto-swing function ensures efficient air and
temperature distribution and prevents ceiling
soiling.
Excellent low draught characteristics
Easy installation and maintenance

BRC7E531

Cooling capacity Standard


Heating capacity Standard
Cooling / Heating

Sound power level


Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

heat pump

standard

2 steps

optional

INVERTER

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD
Weight

Outdoor Unit
Dimensions
Weight
Sound pressure level

RXS25,35E

optional

Heat Pump
Indoor Units
Nominal Capacity

FFQ25,35B

The switch box can be reached by simply


removing the suction grille; therefore
maintenance can be done very easily.

H/L
H/L
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

mm
kg

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FFQ25B8V1B
2.5
3.2
3.42 / 3.48
365
A/B
286x575x575
17.5
9.0 / 6.5
9.0 / 6.5
46.5
29.5 / 24.5
29.5 / 24.5
R-410A
1~/230V/50Hz
BYFQ60BAW1
White(RAL 9010)
55x700x700
2.7

FFQ35B8V1B
3.4
4.0
3.09 / 3.33
550
B/C
286x575x575
17.5
10.0 / 6.5
10.0 / 6.5
49.0
32.0 / 25.0
32.0 / 25.0
R-410A
1~/230V/50Hz
BYFQ60BAW1
White(RAL 9010)
55x700x700
2.7

RXS25E2V1B
550x765x285
32
46 / 43
47 / 44
61
-10~46
-15~20
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

RXS35E2V1B
550x765x285
32
47 / 44
48 / 45
62
-10~46
-15~20
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

47

optional

FFQ-B / RXS-F

4-Way blow ceiling mounted cassette


(600mm x 600mm)

BRC1D52
l

l
l
l

l
l
l

New and extremely compact casing (575mm


in width and depth) enables unit to fit flush
into ceilings and match standard architectural
modules, without cutting ceiling tiles
Modern style decoration panel in white
(RAL9010)
Slim design for flexible installation
Ideal for shops, restaurants or offices requiring
maximum floor space for furniture, decorations
and fittings
Extremely quiet in operation
Possibility to shut 1 or 2 flaps for easy
installation in corners
Auto-swing function ensures efficient air and
temperature distribution and prevents ceiling
soiling.
Excellent low draught characteristics

BRC7E531

Cooling capacity Standard


Heating capacity Standard
Cooling / Heating

Sound power level


Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

heat pump

optional

standard

2 steps

optional

INVERTER

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD
Weight

Outdoor Unit
Dimensions
Weight
Sound pressure level

RXS50,60F

Easy installation and maintenance


l The switch box can be reached by simply
removing the suction grille; therefore
maintenance can be done very easily.

Heat Pump
Indoor Units
Nominal Capacity

FFQ50,60B

H/L
H/L
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)

kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

mm
kg

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m

FFQ50B8V1B
4.7
5.5
2.61 / 2.81
900
D/D
286x575x575
17.5
12.0 / 8.0
12.0 / 8.0
53.0
36.0 / 27.0
36.0 / 27.0
R-410A
1~/230V/50Hz
BYFQ60BAW1
White(RAL 9010)
55x700x700
2.7

FFQ60B8V1B
5.8
7.0
2.80 / 2.81
1035
D/D
286x575x575
17.5
15.0 / 10.0
15.0 / 10.0
58.0
41.0 / 32.0
41.0 / 32.0
R-410A
1~/230V/50Hz
BYFQ60BAW1
White(RAL 9010)
55x700x700
2.7

RXS50F2V1B
735x825x300
48
47 / 44
48 / 45
61
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30

RXS60F2V1B
735x825x300
48
49 / 46
49 / 46
63
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 18
30

48

optional

FCQ-C / RKS-E

Round Flow Cassette

l
l
l
l
l
l
l
l

Modern style decoration panel in white (RAL9010)


360 air discharge ensures uniform air flow and
temperature distribution
Air discharge from the corners avoids dead zones
that may be subject to temperature differences
Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling
23 different air flow patterns possible
Fresh air intake: up to 20 %
Reduced installation height: 214mm for class 35-71
Easy visible drain check thanks to clear drain socket

BRC1D52

BRC7F533

FCQ35C

RKS35E

heat pump

optional

2 steps

optional

optional

Cooling only
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Minimum


Standard
Maximum
Nominal

EER
Annual energy consumption
Energy Label
cooling
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range
Refrigerant
Power Supply
Piping connections
Piping Length (Maximum)

(Height x Width x Depth)


Cooling
Cooling
Cooling

H
H
Min~Max

Liquid (OD)/Gas/Drain

FCQ35C7VEB
1.4
3.4
3.7
3.58
475
A
204x840x840
19
10.5 / 8.5
49
31 / 27
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

kW
kW
kW
kWh
mm
kg
m/min
dBA
dBA
Type

mm

RKS35E2V1B
550x765x285
32
47 / 44
62
-10~+46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 20
20

mm
kg
dBA
dBA
CDB
Type
mm
m

50

FCQ-C / RKS-F

Round Flow Cassette

l
l
l
l
l
l
l
l

Modern style decoration panel in white (RAL9010)


360 air discharge ensures uniform air flow and
temperature distribution
Air discharge from the corners avoids dead zones
that may be subject to temperature differences
Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling
23 different air flow patterns possible
Fresh air intake: up to 20 %
Reduced installation height: 214mm for class 35-71
Easy visible drain check thanks to clear drain socket

BRC1D52

BRC7F533

RKS50,60F

FCQ50,60C

heat pump

optional

2 steps

optional

optional

Cooling only
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Minimum

kW

Standard
Maximum

kW
kW

EER
Nominal
Annual energy consumption
Energy Label
cooling
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD

Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Sound pressure level
Cooling
H/L
Sound power level
Cooling
H
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

kWh
mm
kg
m/min
dBA
dBA
Type

mm

mm
kg
dBA
dBA
CDB
Type
mm
m
m

FCQ50C7VEB
0.9

FCQ60C7VEB
0.9

5.0
5.6
3.55
705
A
204x840x840
19
12.5 / 8.5
49
31 / 27
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

5.7
6.0
3.48
820
A
204x840x840
19
13.5 / 8.5
51
33 / 28
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

RKS50F2V1B
735x825x300
48
47 / 44
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30
20

RKS60F2V1B
735x825x300
47
49 / 46
63
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 18
30
20

51

FCQ-C / RXS-E

Round Flow Cassette

l
l
l
l
l
l
l
l

Modern style decoration panel in white (RAL9010)


360 air discharge ensures uniform air flow and
temperature distribution
Air discharge from the corners avoids dead zones
that may be subject to temperature differences
Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling
23 different air flow patterns possible
Fresh air intake: up to 20 %
Reduced installation height: 214mm for class 35-71
Easy visible drain check thanks to clear drain socket

BRC1D52

BRC7F532

RXS35E

FCQ35C

heat pump

optional

2 steps

optional

optional

Heat Pump
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

H/L
H/L
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)

FCQ35C7VEB
1.4
3.4
3.7
1.4
4.2
5.0
3.58 / 3.41
475
A/B
204x840x840
19
10.5 / 8.5
12.5 / 10.0
49
31 / 27
31 / 27
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

kW
kW
kW
kW
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

mm

RXS35E2V1B
550x765x285
32
47 / 44
48 / 45
62
-10~46
-15~20
R-410A
1~/220-240V/220-230V/50Hz
6.35 / 9.5 / 20
20

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m

52

FCQ-C / RXS-F

Round Flow Cassette

l
l
l

l
l
l
l

Modern style decoration panel in white


(RAL9010)
360 air discharge ensures uniform air flow
and temperature distribution
Air discharge from the corners avoids dead
zones that may be subject to temperature
differences
Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling
soiling
23 different air flow patterns possible
Fresh air intake: up to 20 %
Reduced installation height: 214mm for class
35-71
Easy visible drain check thanks to clear drain
socket

BRC1D52

BRC7F532

RXS50,60F

FCQ50,60C

heat pump

optional

2 steps

optional

optional

Heat Pump
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

H/L
H/L
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)

kW
kW
kW
kW
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

mm

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m

FCQ50C7VEB
0.9
5.0
5.6
0.9
6.0
7.0
3.55 / 3.70
705
A/A
204x840x840
19
12.5 / 8.5
12.5 / 8.5
49
31 / 27
31 / 27
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

FCQ60C7VEB
0.9
5.7
6.0
0.9
7.0
8.0
3.48 / 3.52
820
A/B
204x840x840
19
13.5 / 8.5
13.5 / 8.5
51
33 / 28
33 / 28
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

RXS50F2V1B
735x825x300
48
47 / 44
48 / 45
61
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30

RXS60F2V1B
735x825x300
48
49 / 46
49 / 46
63
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 18
30

53

FCQ-C / REQ-B

Round Flow Cassette

BRC1D52
l
l
l
l
l
l
l
l

BRC7F532

FCQ100,125C

Modern style decoration panel in white (RAL9010)


360 air discharge ensures uniform air flow and
temperature distribution
Air discharge from the corners avoids dead zones
that may be subject to temperature differences
Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling
23 different air flow patterns possible
Fresh air intake: up to 20 %
Reduced installation height: 214mm for class 35-71
Easy visible drain check thanks to clear drain socket

heat pump

optional

Cooling capacity Standard


Heating capacity Standard
Cooling / Heating

FCQ71C7VEB
7.1
7.1
8.0
8.0
2.61 / 2.81
2.67 / 2.86
1360
1330
D/D
204x840x840
21
15.5 / 9.0
16.0 / 9.5
51
33 / 28
34 / 28
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

mm

REQ71B8V3B
(Height x Width x Depth)
Cooling
Cooling
Cooling
Heating

optional

NON-INVERTER

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

optional

2 steps

Heat Pump
Indoor Units
Nominal Capacity

REQ100B

Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

mm
kg
dBA
dBA
CDB
CWB
Type

53
65

1~/230V/50Hz

REQ71B8W1B
770x900x320
83
53
65

3N~/400V/50Hz

mm
m
m

54

FCQ100C7VEB
10.0
10.0
11.2
11.2
2.61 / 2.99
2.81 / 3.06
1915
1780
D/D
C/D
246x840x840
23
23.5 / 16.0
23.5 / 16.0
54
37 / 32
37 / 32
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

REQ100B8V3B
102
57
70
10.0~46.0
-10~15
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

FCQ125C7VEB
12.5
14.6
2.68 / 2.89
2330
D/D
246x840x840
23
27.5 / 19.0
27.5 / 19.0
58
41 / 35
41 / 35
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

REQ100B8W1B
1170x900x320
100
57
70

REQ125B8W1B

3N~/400V/50Hz

108
57
70

FCQ-C / RZQS-B/C

Round Flow Cassette

BRC1D52
l
l
l

l
l
l
l

BRC7F532

FCQ100,125,140C

Modern style decoration panel in


white (RAL9010)
360 air discharge ensures uniform air
flow and temperature distribution
Air discharge from the corners avoids
dead zones that may be subject to
temperature differences
Comfortable horizontal air discharge
ensures draughtfree operation and
prevents ceiling soiling
23 different air flow patterns possible
Fresh air intake: up to 20 %
Reduced installation height: 214mm
for class 35-71
Easy visible drain check thanks to clear
drain socket

heat pump

optional

2 steps

Heat Pump
Indoor Units
Nominal Capacity

Cooling capacity Standard


Heating capacity Standard
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling (Night quiet mode)
Heating
Cooling
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

RZQS125,140C

optional

optional

comfort INVERTER
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

mm

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FCQ71C7VEB
7.1
8.0
2.89 / 3.07
1230
C/D
204x840x840
21
15.5 / 9.0
16.0 / 9.5
51
33 / 28
34 / 28
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

FCQ100C7VEB
10.0
11.2
2.61 / 3.23
1915
D/C
246x840x840
23
23.5 / 16.0
23.5 / 16.0
54
37 / 32
37 / 32
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

FCQ125C7VEB
12.5
14.0
3.02 / 3.10
2070
B/D
246x840x840
23
27.5 / 19.0
27.5 / 19.0
58
41 / 35
41 / 35
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

FCQ140C7VEB
14.0
16.0
2.61 / 2.81
2680
D/D
246x840x840
23
27.5 / 19.0
27.5 / 19.0
58
41 / 35
42 / 35
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

RZQS71B7V3B
770x900x320
68
49 (43)
51
65
-5.0~46.0
-15.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
30
15

RZQS100B7V3B
770x900x320
68
51 (45)
55
67
-5.0~46.0
-15.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

RZQS125C7V1
1170x900x320
103
51 (49)
53
67
-5~46
-15~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

RZQS140C7V1
1170x900x320
103
52 (50)
54
68
-5~46
-15~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

55

FCQ-C / RZQ-B/C

Round Flow Cassette

l
l
l
l
l
l
l
l

Modern style decoration panel in white (RAL9010)


360 air discharge ensures uniform air flow and
temperature distribution
Air discharge from the corners avoids dead zones
that may be subject to temperature differences
Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling
23 different air flow patterns possible
Fresh air intake: up to 20 %
Reduced installation height: 214mm for class 35-71
Easy visible drain check thanks to clear drain socket

BRC1D52

BRC7F532

RZQ100,125,140C

FCQ100,125,140C

heat pump

optional

2 steps

optional

optional

Heat Pump
Indoor Units
Nominal Capacity

Cooling capacity Standard


Heating capacity Standard
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling (Night quiet mode)
Heating
Cooling
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

super INVERTER
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

mm

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FCQ71C7VEB
7.1
8.0
3.29 / 3.13
1080
A/D
204x840x840
21
15.5 / 9.0
16.0 / 9.5
51
33 / 28
35 / 28
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

RZQ71B9V3B1
770x900x320
68
47 (43)
49
63
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

FCQ100C7VEB
10.0
10.0
11.2
11.2
3.61 / 3.71
3.79 / 3.57
1385
1320
A/A
A/B
246x840x840
23
23.5 / 16.0
23.5 / 16.0
58
37 / 32
37 / 32
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

RZQ100C7V1B
1170x900x320
103
49 (45)
51
65
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

56

RZQ100B8W1B
1345x900x320
106
49 (45)
51
65
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

FCQ125C7VEB
12.5
12.5
14.0
14.0
3.22 / 3.54
3.22 / 3.21
1940
1940
A/B
A/C
246x840x840
23
27.5 / 19.0
27.5 / 19.0
58
41 / 35
41 / 35
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

RZQ125C7V1B
1170x900x320
103
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

RZQ125B8W1B
1345x900x320
106
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

FCQ140C7VEB
14.0
14.0
16.0
16.0
2.61 / 3.21
2.61 / 2.81
2680
2680
D/C
D/D
246x840x840
23
27.5 / 19.0
27.5 / 19.0
58
41 / 35
42 / 35
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

RZQ140C7V1B
1170x900x320
103
50 (46)
52
67
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

RZQ140B8W1B
1345x900x320
106
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

FCQH-C / RZQS-B/C
High Efficiency
Round Flow Cassette

l
l
l
l
l
l
l
l

Improved operating efficiency


Modern style decoration panel in white (RAL9010)
360 air discharge ensures uniform air flow and
temperature distribution
Air discharge from the corners avoids dead zones
that may be subject to temperature differences
Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling
23 different air flow patterns possible
Fresh air intake: up to 20 %
Easy visible drain check thanks to clear drain socket

BRC1D52

BRC7F532

RZQS71,100B

FCQH71C

heat pump

optional

2 steps

optional

optional

Heat Pump
Indoor Units
Nominal Capacity

Cooling capacity Standard


Heating capacity Standard
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling (Night quiet mode)
Heating
Cooling
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

comfort INVERTER
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

mm

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FCQH71C7VEB
7.1
8.0
3.01 / 3.42
1315
B/B
246x840x840
23
20.0 / 12.0
20.0 / 12.0
51
34 / 28
34 / 28
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

FCQH100C7VEB
10.0
11.2
2.81 / 3.41
1780
C/B
288x840x840
25
32.5 / 18.0
32.5 / 18.0
54
43 / 32
43 / 32
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

FCQH125C7VEB
12.5
14.0
3.22 / 3.41
1940
A/B
288x840x840
25
32.5 / 21.5
32.5 / 21.5
58
43 / 36
43 / 36
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

FCQH140C7VEB
14.0
16.0
2.81 / 3.21
2490
C/C
288x840x840
25
32.5 / 21.5
32.5 / 21.5
58
43 / 38
43 / 38
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

RZQS71B7V3B
770x900x320
68
49 (43)
51
65
-5.0~46.0
-15.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
30
15

RZQS100B7V3B
770x900x320
68
51 (45)
55
67
-5.0~46.0
-15.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

RZQS125C7V1
1170x900x320
103
51 (49)
53
67
-5~46
-15~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

RZQS140C7V1
1170x900x320
103
52 (50)
54
68
-5~46
-15~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

57

FCQH-C / RZQ-B/C
High Efficiency
Round Flow Cassette

l
l
l
l
l
l
l
l

Improved operating efficiency


Modern style decoration panel in white (RAL9010)
360 air discharge ensures uniform air flow and
temperature distribution
Air discharge from the corners avoids dead zones
that may be subject to temperature differences
Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling
23 different air flow patterns possible
Fresh air intake: up to 20 %
Easy visible drain check thanks to clear drain socket

BRC1D52

BRC7F532

RZQ125B

FCQH100,125,140C

heat pump

optional

2 steps

optional

optional

Heat Pump
Indoor Units
Nominal Capacity

Cooling capacity Standard


Heating capacity Standard
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
Cooling / Heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply
Decoration Panel
Model
Colour
HxWxD

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling (Night quiet mode)
Heating
Cooling
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

super INVERTER
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

mm

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FCQH71C7VEB
7.1
8.0
3.58 / 4.06
990
A/A
246x840x840
23
20.0 / 12.0
20.0 / 12.0
51
34 / 28
34 / 28
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

RZQ71B9V3B1
770x900x320
68
47 (43)
49
63
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

FCQH100C7VEB
10.0
10.0
11.2
11.2
3.76 / 4.39
4.10 / 4.38
1330
1220
A/A
A/A
288x840x840
25
32.5 / 18.0
32.5 / 18.0
54
43 / 32
43 / 32
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

RZQ100C7V1B
1170x900x320
103
49 (45)
51
65
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

58

RZQ100B8W1B
1345x900x320
106
49 (45)
51
65
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

FCQH125C7VEB
12.5
12.5
14.0
14.0
3.38 / 3.92
3.53 / 3.90
1850
1770
A/A
A/A
288x840x840
25
32.5 / 21.5
32.5 / 21.5
58
43 / 36
43 / 36
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

RZQ125C7V1B
1170x900x320
103
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

RZQ125B8W1B
1345x900x320
106
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

FCQH140C7VEB
14.0
14.0
16.0
16.0
3.02 / 3.61
3.01 / 3.54
2320
2325
B/A
B/B
288x840x840
25
32.5 / 21.5
32.5 / 21.5
58
43 / 38
43 / 38
R-410A
1~/220-240V/50/60Hz
BYCQ140CW1
Pure White (RAL 9010)
50x950x950

RZQ140C7V1B
1170x900x320
103
50 (46)
52
67
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

RZQ140B8W1B
1345x900x320
106
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

FUQ-B / RZQ-B/C
Cooling Only/Heat Pump

FUQ71B
l
l

l
l
l
l
l
l
l

Can be installed in both new and existing buildings.


Ideal for shops, restaurants or offices requiring
maximum floor space for furniture, decorations and
fittings
Air can be discharged in any of 4 directions
Air flow distribution for ceiling heights up to 3.5m
without loss of capacity.
No ceiling staining
Possibility to shut 1 or 2 flaps for easy installation in
corners
Air filter, drain pan and heat exchanger fin are
mildew proof and anti-bacterial treated.
Drain-up pump with 500mm lift fitted as standard
Easy to install

BRC1D52

heat pump

Cooling capacity Standard


Heating capacity Standard

Annual energy consumption


EER / COP
Cooling / Heating
Energy Label
Cooling / Heating
Dimensions
HxWxD
Weight
Sound power level
Cooling
H/L
Sound pressure level
Cooling
H/L
Heating
H/L
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling (Night quiet mode)
Heating
Cooling
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

optional

standard

2 steps

optional

optional

Heat Pump
Indoor Units
Nominal Capacity

RZQ100,125B

BRC7C528

super INVERTER
kW
kW
kWh

mm
kg
dB(A)
dB(A)
dB(A)
Type

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FUQ71BVV1B
7.1
8.0
1105
3.21 / 3.42
A/B
165x895x895
25
56/51
40/35
40/35
R-410A
1~/230V/50Hz

RZQ71B9V3B1
770x900x320
68
47 (43)
49
63
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

FUQ100BVV1B
10.0
11.2
1560
3.21 / 3.32
A/C

FUQ125BVV1B
10.0
11.2
1560
3.21 / 3.41
A/B

12.5
14.0
2075
3.01 / 3.23
B/C

12.5
14.0
2025
3.09 / 3.21
B/C

230x895x895
31
59/54
43/38
43/38
R-410A
1~/230V/50Hz

RZQ100C7V1B
1170x900x320
103
49 (45)
51
65
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

59

RZQ100B8W1B
1345x900x320
106
49 (45)
51
65
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

31
60/55
44/39
44/39
R-410A
1~/230V/50Hz

RZQ125C7V1B
1170x900x320
103
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

RZQ125B8W1B
1345x900x320
106
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

60

FHQ-B / RKS-E
Ceiling suspended unit

BRC1D52
l
l
l
l
l
l

BRC7E66

RKS35E

FHQ35B

Ideal solution for shops, restaurants or offices


without false ceilings
Compact design
Leaves maximum floor and wall space for furniture,
decorations and fittings
Easy installation and maintenance
Auto-swing function ensures efficient air and
temperature distribution.
Air flow distribution for ceiling heights up to 3.8m
without loss of capacity.

heat pump

2 steps

35~60

optional

Cooling only
Indoor Units
Nominal Capacity

Cooling capacity Minimum


Standard
Maximum
Nominal

EER
Annual energy consumption
Energy Label
cooling
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Sound Power
Cooling
High/Low
Sound Pressure
Cooling
High/Low
Refrigerant
Power Supply

Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Sound pressure level
Cooling
H/L
Sound power level
Cooling
H
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

optional

INVERTER
FHQ35BVV1B
1.4
3.4
3.7
3.24
525
A
195x960x680
24.0
13.0 / 10.0
53.0 / 48.0
37.0 / 32.0
R-410A
1~/220-240V/50Hz

kW
kW
kW
kWh
mm
kg
m/min
dBA
dBA
Type

RKS35E2V1B
550x765x285
32
47 / 44
62
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20
15

mm
kg
dBA
dBA
CDB
Type
mm
m
m

61

FHQ-B / RKS-F
Ceiling suspended unit

l
l
l
l
l
l

Ideal solution for shops, restaurants or offices


without false ceilings
Compact design
Leaves maximum floor and wall space for furniture,
decorations and fittings
Easy installation and maintenance
Auto-swing function ensures efficient air and
temperature distribution.
Air flow distribution for ceiling heights up to 3.8m
without loss of capacity.

BRC1D52

BRC7E66

FHQ50B

RKS50,60F

heat pump

2 steps

35~60

optional

Cooling only
Indoor Units
Nominal Capacity

Cooling capacity Minimum


Standard
Maximum
Nominal

EER
Annual energy consumption
Energy Label
cooling
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Sound Power
Cooling
High/Low
Sound Pressure
Cooling
High/Low
Refrigerant
Power Supply

Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Sound pressure level
Cooling
H/L
Sound power level
Cooling
H
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

INVERTER
kW
kW
kW
kWh
mm
kg
m/min
dBA
dBA
Type

mm
kg
dBA
dBA
CDB
Type
mm
m
m

optional

FHQ50BVV1B
1.7
5.0
5.6
2.73
915
D
195x960x680
25.0
13.0 / 10.0
54.0 / 49.0
38.0 / 33.0
R-410A
1~/220-240V/50Hz

FHQ60BVV1B
1.7
5.7
6.0
2.65
1075
D
195x1160x680
27.0
17.0 / 13.0
55.0 / 49.0
39.0 / 33.0
R-410A
1~/220-240V/50Hz

RKS50F2V1B
735x825x300
48
47 / 44
61
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30
20

RKS60F2V1B
735x825x300
47
49 / 46
63
-10~46
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 18
30
20

62

FHQ-B / RXS-E
Ceiling suspended unit

BRC7E63

BRC1D52
l
l
l
l
l
l

FHQ35B

Ideal solution for shops, restaurants or offices


without false ceilings
Compact design
Leaves maximum floor and wall space for
furniture, decorations and fittings
Easy installation and maintenance
Auto-swing function ensures efficient air and
temperature distribution.
Air flow distribution for ceiling heights up to
3.8m without loss of capacity.

RXS35E

heat pump

2 steps

35~60

optional

Heat Pump
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High/Low
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

H/L
H/L
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)

optional

FHQ35BVV1B
1.4
3.4
3.7
1.2
4.0
5.0
3.24 / 3.60
525
A/B
195x960x680
24.0
13.0 / 10.0
13.0 / 10.0
53.0 / 48.0
37.0 / 32.0
37.0 / 32.0
R-410A
1~/220-240V/50Hz

kW
kW
kW
kW
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

RXS35E2V1B
550x765x285
32
47 / 44
48 / 45
62
-10~46
-15~20
R-410A
1~/220-240V/50Hz
6.35 / 9.5 / 18
20

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m

63

FHQ-B / RXS-F
Ceiling suspended unit

BRC7E63

BRC1D52
l
l
l
l
l
l

FHQ50B

Ideal solution for shops, restaurants or offices


without false ceilings
Compact design
Leaves maximum floor and wall space for
furniture, decorations and fittings
Easy installation and maintenance
Auto-swing function ensures efficient air and
temperature distribution
Air flow distribution for ceiling heights up to
3.8m without loss of capacity.

RXS50,60F

heat pump

2 steps

35~60

optional

Heat Pump
Indoor Units
Nominal Capacity

INVERTER

Cooling capacity Minimum


Standard
Maximum
Heating capacity Minimum
Standard
Maximum
Cooling / Heating

EER / COP
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High/Low
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

H/L
H/L
H
Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)

kW
kW
kW
kW
kW
kW
kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m

optional

FHQ50BVV1B
1.7
5.0
5.6
0.9
1.7
7.0
2.73 / 2.93
915
D/D
195x960x680
25.0
13.0 / 10.0
13.0 / 10.0
54.0 / 49.0
38.0 / 33.0
38.0 / 33.0
R-410A
1~/220-240V/50Hz

FHQ60BVV1B
1.7
5.7
6.0
1.7
7.2
8.0
2.65 / 2.89
1075
D/D
195x1160x680
27.0
17.0 / 13.0
16.0 / 13.0
55.0 / 49.0
39.0 / 33.0
39.0 / 33.0
R-410A
1~/220-240V/50Hz

RXS50F2V1B
735x825x300
48
47 / 44
48 / 45
61
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 20
30

RXS60F2V1B
735x825x300
48
49 / 46
49 / 46
63
-10~46
-15~18
R-410A
1~/220-240V/50Hz
6.35 / 12.7 / 18
30

64

FHQ-B / REQ-B
Ceiling Suspended Unit

FHQ71B
BRC1D52
l
l
l
l
l
l

REQ71B

BRC7E66

Ideal solution for shops, restaurants or offices


without false ceilings
Compact design
Leaves maximum floor and wall space for furniture,
decorations and fittings
Easy installation and maintenance
Auto-swing function ensures efficient air and
temperature distribution.
Air flow distribution for ceiling heights up to 3.8m
without loss of capacity.

heat pump

2 steps

optional

Heat Pump
Indoor Units
Capacity

NON-INVERTER

Cooling capacity Standard


Heating capacity Standard

Annual energy consumption


EER / COP
Cooling / Heating
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High/Low
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Operation Range
Sound Level (nominal)

kW
kW
kWh

FHQ71BVV1B
7.1
8
1350
2.63 / 2.81

Cooling
Heating
Sound Power
Sound Pressure

Min~Max
Min~Max
Cooling
Cooling

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

FHQ100BVV1B
9.8
11.2
1325
2.68 / 2.86

1875
2.61 / 2.71

D/D
195x1160x680
27.0
17.0 / 14.0
17.0 / 14.0
55.0 / 51.0
39.0 / 35.0
39.0 / 35.0

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

FHQ125BVV1B
12.2
14.5
2255
2.71 / 2.81
D/D
195x1590x680
35.0
30.0 / 25.0
30.0 / 25.0
60.0 / 55.0
44.0 / 39.0
44.0 / 39.0

1840
2.66 / 2.79
D/E
195x1400x680
32.0
24.0 / 20.0
24.0 / 20.0
58.0 / 53.0
42.0 / 37.0
42.0 / 37.0

R-410A
1~/220-240V/50Hz

REQ71B8V3B
(Height x Width x Depth)

optional

mm
kg
CDB
CWB
dBA
dBA
Type

REQ71B8W1B
770x900x320
83

REQ100B8V3B
102
10.0~46.0
-10~15

65.0
53.0
1~/230V/50Hz

REQ100B8W1B
1170x900x320
100

REQ125B8W1B

70.0
57.0
3N~/400V/50Hz

mm
m
m

65

R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

3N~/400V/50Hz

108

FHQ-B / RZQS-B/C

FHQ71B
l
l
l
l
l
l

Ideal solution for shops, restaurants or offices


without false ceilings
Compact design
Leaves maximum floor and wall space for
furniture, decorations and fittings
Easy installation and maintenance
Auto-swing function ensures efficient air and
temperature distribution.
Air flow distribution for ceiling heights up to
3.8m without loss of capacity.

BRC1D52

heat pump

2 steps

Cooling capacity Standard


Heating capacity Standard

Annual energy consumption


EER / COP
Cooling / Heating
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High/Low
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling (Night quiet mode)
Heating
Cooling
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

comfort INVERTER
kW
kW
kWh

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

optional

optional

Heat Pump
Indoor Units
Nominal Capacity

RZQS125C

BRC7E63

FHQ71BVV1B
7.10
8.00
1265
2.81 / 2.82
C/D
195x1160x680
27.0
17.0 / 14.0
17.0 / 14.0
55.0 / 51.0
39.0 / 35.0
39.0 / 35.0
R-410A
1~/220-240V/50Hz

FHQ100BVV1B
10.00
11.20
2075
2.41 / 2.81
E/D
195x1400x680
32.0
24.0 / 20.0
24.0 / 20.0
58.0 / 53.0
42.0 / 37.0
42.0 / 37.0
R-410A
1~/220-240V/50Hz

FHQ125BVV1B
12.5
14.0
2290
2.73 / 2.82
D/D
195x1590x680
35.0
30.0 / 25.0
30.0 / 25.0
60.0 / 55.0
44.0 / 39.0
44.0 / 39.0
R-410A
1~/220-240V/50Hz

RZQS71B7V3B
770x900x320
68
49 (43)
51
65
-5.0~46.0
-15.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
30
15

RZQS100B7V3B
770x900x320
68
51 (45)
55
67
-5.0~46.0
-15.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

RZQS125C7V1
1170x900x320
103
51 (49)
53
67
-5.0~46.0
-15.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

66

FHQ-B / RZQ-B/C
Ceiling Suspended unit

l
l
l
l
l
l

Ideal solution for shops, restaurants or offices


without false ceilings
Compact design
Leaves maximum floor and wall space for
furniture, decorations and fittings
Easy installation and maintenance
Auto-swing function ensures efficient air and
temperature distribution.
Air flow distribution for ceiling heights up to
3.8m without loss of capacity.

BRC1D52

FUQ71B

BRC7E63

RZQ100,125C

heat pump

2 steps

optional

Heat Pump
Indoor Units
Nominal Capacity

super INVERTER

Cooling capacity Standard

kW

Heating capacity Standard


EER / COP
Cooling / Heating
Annual energy consumption
Energy Label
cooling / heating
Dimensions
(Height x Width x Depth)
Weight
Air Flow Rate
Cooling
High/Low
Heating
High/Low
Sound Power
Cooling
High/Low
Sound Pressure
Cooling
High/Low
Heating
High/Low
Refrigerant
Power Supply

kW

Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling (Night quiet mode)
Heating
Cooling
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

kWh
mm
kg
m/min
m/min
dBA
dBA
dBA
Type

mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

FHQ71BVV1B
7.1
8.0
2.89 / 3.00
1230
A/D
195x1160x680
27.0
17.0 / 14.0
17.0 / 14.0
55.0 / 51.0
39.0 / 35.0
39.0 / 35.0
R-410A
1~/220-240V/50Hz

RZQ71B9V3B1
770x900x320
68
47 (43)
49
63
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

FHQ100BVV1B
10.0

FHQ125BVV1B
12.5

11.2

14.0

3.03 / 3.21
1650
B/C

3.17 / 3.11
1575
B/D
195x1400x680
32.0
24.0 / 20.0
24.0 / 20.0
58.0 / 53.0
42.0 / 37.0
42.0 / 37.0
R-410A
1~/220-240V/50Hz

RZQ100C7V1B
1170x900x320
103
49 (45)
51
65
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

67

RZQ100B8W1B
1345x900x320
106
49 (45)
51
65
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

2.81 / 3.21
2225
C/C

2.81 / 3.11
2225
C/D
195x1590x680
35.0
30.0 / 25.0
30.0 / 25.0
60.0 / 55.0
44.0 / 39.0
44.0 / 39.0
R-410A
1~/220-240V/50Hz

RZQ125C7V1B
1170x900x320
103
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

RZQ125B8W1B
1345x900x320
106
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

optional

Twin / triple / double twin applications


&
Multi Model applications

68

It is possible to connect 2,3 or 4 indoor units to a single outdoor


unit. The indoor units may be of different types (e.g. 4-way blow
ceiling mounted cassette, wall mounted, ...) and even different
capacities (e.g. 35 and 71 class).
All indoor units are operated together within the same mode
(cooling or heating) from one remote control. This allows equal air
distribution, even in larger, irregularly shaped rooms.
The total capacities (outdoor base) for simultaneous operation are
the same as for the pair applications.

Connectable indoor units:


Inverter controlled:
RZQ-B/C: FCQH-C, FCQ-C, FHQ-B, FUQ-B, FAQ-B, FDQ-B
RZQS-B/C: FCQH-C, FCQ-C, FFQ-B, FBQ-B, FHQ-B, FAQ-B, FDQ-B

Possible combinations
Twin

Triple

Double twin

RZQ71
RZQS71

35+35
(KHRQ22M20TA)

RZQ100
RZQS100

50+50
(KHRQ22M20TA)

35+35+35
(KHRQ127H)

RZQ125
RZQS125

60+60
(KHRQ22M20TA)

50+50+50
(KHRQ127H)

35+35+35+35
(3 x KHRQ22M20TA)

RZQ140
RZQS140

71+71
(KHRQ22M20TA)

50+50+50
(KHRQ22M20TA)

35+35+35+35
(3 x KHRQ22M20TA)

RZQ200

100+100
(KHRQ22M20TA)

60+60+60
(KHRQ250H7)

RZQ250

125+125
(KHRQ22M20TA)

71+71+71
(KHRQ250H7)

50+50+50+50
(3 x KHRQ22M20TA)
60+60+60+60
(3 x KHRQ22M20TA)

69

FAQ,FBQ,FCQ,
FCQH,FFQ,FHQ + RZQS

Heat Pump
Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High/Low
High/Low
High/Low

Refrigerant
Power Supply

FAQ71BVV1B
290x1050x230
13.0
19.0 / 15.0
19.0 / 15.0
59.0 / 53.0
43.0 / 37.0
43.0 / 37.0
R-410A
1~/220-240V/50Hz

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

Heat Pump
Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

FBQ35B8V1
FBQ35B8V1
(Height x Width x Depth)
Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High
High/Low
High/Low

Refrigerant
Power Supply

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

FBQ50B8V1
FBQ50B8V1

FBQ60B8V1
FBQ60B8V1

300x700x800
30
11.5 / 9
11.5 / 9
52

FBQ71B8V3B
FBQ71B8V3B
300x1000x800

31
14 / 10
14 / 10

41
19 / 14
19 / 14

53

60

33 / 29
33 / 29

41
19 / 14
19 / 14
60
34 / 30
34 / 30

R-410A
1~/230V/50Hz

Heat Pump
Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power level
Sound Pressure
Refrigerant
Power Supply

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High
High/Low
High/Low

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

FCQ35C7VEB
204x840x840
19
10.0 / 8.5
12.5 / 10.0
49
31 / 27
31 / 27
R-410A
1~/220-240V/50/60Hz

FCQ50C7VEB
204x840x840
19
12.5 / 8.5
12.5 / 8.5
49
32 / 27
32 / 27
R-410A
1~/220-240V/50/60Hz

70

FCQ60C7VEB
204x840x840
19
13.5 / 8.5
13.5 / 8.5
51
33 / 28
33 / 28
R-410A
1~/220-240V/50/60Hz

FCQ71C7VEB
204x840x840
21
15.5 / 9.0
16.5 / 9.5
51
33 / 28
34 / 28
R-410A
1~/220-240V/50/60Hz

Heat Pump
Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power level
Sound Pressure

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High
High/Low
High/Low

Refrigerant
Power Supply

FCQH71CVEB
246x840x840
23
20.0 / 12.0
20.0 / 12.0
52.0
34 / 28
34 / 28
R-410A
1~/220-240V/50/60Hz

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

Heat Pump
Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

FFQ35B8V1B
(Height x Width x Depth)
Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High
High/Low
High/Low

Refrigerant
Power Supply

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

FFQ50B8V1B
286x575x575
17,5
12.0 / 8.0
12.0 / 8.0
53.0
36.0 / 27.0
36.0 / 27.0
R-410A
1~/230V/50Hz

10.0 / 6.5
10.0 / 6.5
49.0
32.0 / 25.0
32.0 / 25.0

FFQ60B8V1B

15.0 / 10.0
15.0 / 10.0
58.0
41.0 / 32.0
41.0 / 32.0

Heat Pump
Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

FHQ35BVV1B
(Height x Width x Depth)
Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High/Low
High/Low
High/Low

Refrigerant
Power Supply

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

FHQ50BVV1B

24.0

25.0

53.0 / 48.0
37.0 / 32.0
37.0 / 32.0

Sound power level


Operation Range

(Height x Width x Depth)


Cooling (Night quiet mode)
Heating
Cooling
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

FHQ71BVV1B
195x1160x680
27.0

13.0 / 10.0
13.0 / 10.0

17.0 / 13.0
16.0 / 13.0
55.0 / 49.0
39.0 / 33.0
39.0 / 33.0

54.0 / 49.0
38.0 / 33.0
38.0 / 33.0

17.0 / 14.0
17.0 / 14.0
55.0 / 51.0
39.0 / 35.0
39.0 / 35.0

R-410A
1~/220-240V/50Hz

Heat Pump
Outdoor Unit
Dimensions
Weight
Sound pressure level

FHQ60BVV1B

195x960x680

INVERTER
mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

RZQS71B7V3B
770x900x320
68
49 (43)
51
65
-5.0~46.0
-15.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
30
15

RZQS100B7V3B
770x900x320
68
51 (45)
55
67
-5.0~46.0
-15.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

71

RZQS125C7V1
1170x900x320
103
51 (49)
53
67
-5~46
-15~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

RZQS140C7V1
1170x900x320
103
52 (50)
54
68
-5~46
-15~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

FAQ,FBQ,FCQ,FCQH,
FDQ,FFQ,FHQ,
FUQ + RZQ

Heat Pump
Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High/Low
High/Low
High/Low

Refrigerant
Power Supply

FAQ71BVV1B
290x1050x230
13.0
19.0 / 15.0
19.0 / 15.0
59.0 / 53.0
43.0 / 37.0
43.0 / 37.0

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

FAQ100BVV1B
360x1570x200
26.0
23.0 / 19.0
23.0 / 19.0
61.0 / 57.0
45.0 / 41.0
45.0 / 41.0
R-410A
1~/220-240V/50Hz

Heat Pump
Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High
High/Low
High/Low

Refrigerant
Power Supply

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

FBQ35B8V1
FBQ50B8V1
FBQ60B8V1
FBQ71B8V3B
FBQ100B8V3B
FBQ125B8V3B
FBQ71B8V3B
FBQ100B8V3B
FBQ125B8V3B
FBQ35B8V1
FBQ50B8V1
FBQ60B8V1
300x1000x800
300x1400x800
300x1000x800300x700x800
300x1400x800
300x700x800
300x1000x800
30
31
41
51
52
41.0
51.0
52.0
30
31
41
11.5/ 14.00
/9
14 / 20.00
10
27 / 10
20
35 / 14
24
19.00
27.00
35.00 / 24.00 19 / 14
11.5 / 9
14
19
11.5/ 14.00
/9
14 / 20.00
10
27 / 10
20
35 / 14
24
19.00
27.00
35.00 / 24.00 19 / 14
11.5 / 9
14
19
52
53
60
62
63
60.0
62.0
63.0
52
53
60
33 / 29 36.0 / 31.0
36 / 31
38 / 30
32
34.0 / 30.0
38.0 / 32.0 34 / 30
33 / 29
34
33 / 29 36.0 / 31.0
36 / 31
38 / 30
32
34.0 / 30.0
38.0 / 32.0 34 / 30
33 / 29
34
R-410A
1~/230V/50Hz

Heat Pump
Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power level
Sound Pressure

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High
High/Low
High/Low

Refrigerant
Power Supply

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

FCQ35C7VEB
214x840x840
19
10.0 / 8.5
12.5 / 10.0
49
31 / 27
31 / 27
R-410A
1~/220-240V/50/60Hz

FCQ50C7VEB
214x840x840
19
12.5 / 8.5
12.5 / 8.5
49
32 / 27
32 / 27
R-410A
1~/220-240V/50/60Hz

FCQ60C7VEB
214x840x840
19
13.5 / 8.5
13.5 / 8.5
51
33 / 28
33 / 28
R-410A
1~/220-240V/50/60Hz

FCQ71C7VEB
214x840x840
21
15.5 / 9.0
16.5 / 9.5
51
33 / 28
34 / 28
R-410A
1~/220-240V/50/60Hz

Heat Pump
Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power level
Sound Pressure
Refrigerant
Power Supply

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High
High/Low
High/Low

FCQH71C7VEB
256x840x840
23
20.0 / 12.0
20.0 / 12.0
52.0
34 / 28
34 / 28
R-410A
1~/220-240V/50/60Hz

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

72

FCQ100C7VEB
256x840x840
23
23.5 / 16.0
23.5 / 16.0
54
37 / 32
37 / 32
R-410A
1~/220-240V/50/60Hz

FCQ125C7VEB
256x840x840
23
27.5 / 19.0
27.5 / 19.0
58
41 / 35
41 / 35
R-410A
1~/220-240V/50/60Hz

Heat Pump
Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

Medium
Medium
Medium
High
Low

Refrigerant
Power Supply

FDQ125B8V3B
350x1400x662
59.0
43.0
43.0
75.0
44.0
44.0
R-410A
1~/230V/50Hz

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

Heat Pump
Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

FFQ35B8V1B
(Height x Width x Depth)
Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High
High/Low
High/Low

Refrigerant
Power Supply

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

FFQ50B8V1B
286x575x575
17.5
12.0 / 8.0
12.0 / 8.0
53.0
36.0 / 27.0
36.0 / 27.0
R-410A
1~/230V/50Hz

10.0 / 6.5
10.0 / 6.5
49.0
32.0 / 25.0
32.0 / 25.0

FFQ60B8V1B

15.0 / 10.0
15.0 / 10.0
58.0
41.0 / 32.0
41.0 / 32.0

Heat Pump
Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High/Low
High/Low
High/Low

Refrigerant
Power Supply

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

FHQ35BVV1B
FHQ50BVV1B
195x960x680
24.0
25.0
13.0 / 10.0
13.0 / 10.0
53.0 / 48.0
54.0 / 49.0
37.0 / 32.0
38.0 / 33.0
37.0 / 32.0
38.0 / 33.0

FHQ60BVV1B
FHQ71BVV1B
195x1160x680
27.0
17.0 / 13.0
17.0 / 14.0
16.0 / 13.0
17.0 / 14.0
55.0 / 49.0
55.0 / 51.0
39.0 / 33.0
39.0 / 35.0
39.0 / 33.0
39.0 / 35.0
R-410A
1~/220-240V/50Hz

FUQ71BVV1B
165x895x895
25
19/14
19/14
40/35
56/51
56/51

FUQ100BVV1B

FHQ100BVV1B
195x1400x680
32.0
24.0 / 20.0
24.0 / 20.0
58.0 / 53.0
42.0 / 37.0
42.0 / 37.0

FHQ125BVV1B
195x1590x680
35.0
30.0 / 25.0
30.0 / 25.0
60.0 / 55.0
44.0 / 39.0
44.0 / 39.0

Heat Pump
Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

(Height x Width x Depth)


Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High/Low
High/Low
High/Low

Refrigerant
Power Supply

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

29/21
29/21
43/38
59/54
59/54
R-410A
1~/220-240V/50Hz

Heat Pump
Outdoor Unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation Range

(Height x Width x Depth)


Cooling (Night quiet mode)
Heating
Cooling
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Piping Length (Maximum)
Max. internunit level difference

FUQ125BVV1B
230x895x895
31
32/23
32/23
44/39
60/55
60/55

INVERTER
mm
kg
dBA
dBA
dBA
CDB
CWB
Type
mm
m
m

RZQ71B9V3B1
770x900x320
68
47 (43)
49
63
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
50
30

RZQ100C7V1B
1170x900x320
103
49 (45)
51
65
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

RZQ100B8W1B
1345x900x320
106
49 (45)
51
65
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

73

RZQ125C7V1B
1170x900x320
103
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

RZQ125B8W1B
1345x900x320
106
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

RZQ140C7V1B
1170x900x320
103
50 (46)
52
67
-15.0~50.0
-20.0~15.5
R-410A
1~/230V/50Hz
9.52 / 15.9 / 26
75
30

RZQ140B8W1B
1345x900x320
106
50 (45)
52
66
-15.0~50.0
-20.0~15.5
R-410A
3N~/400V/50Hz
9.52 / 15.9 / 26
75
30

RZQ200C7Y1B
1680x930x765
183
57 (-)
78
-15.0~50.0
-20.0~15.5
R-410A
3N~/380-415V/50Hz
9.5 / 22.2 / 100
30

RZQ250C7Y1B
1680x930x765
184
57 (-)
78
-15.0~50.0
-20.0~15.5
R-410A
3N~/380-415V/50Hz
12.7 / 22.2 / 100
30

MKS-E/F
Multi model application
Inverter controlled

CONNECTABLE INDOOR UNITS


2MKS40F
FTKS20,25,35DW/L
FTKS20,25,35C
FVXS25,35F
FLKS25,35B
FDKS25,35E
-

Wall mounted unit


Wall mounted unit
Floor standinig unit
Flexi type unit
Slim concealed ceiling unit
Concealed ceiling unit
4-way blow ceiling mounted cassette (600x600)
Round flow cassette
Ceiling suspended cassette

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure
Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound power level
Sound Pressure
Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure
Refrigerant
Power Supply

2MKS50F
FTKS20,25,35DW/L
FTKS20,25,35C
FVXS25,35,50F
FLKS25,35,50B
FDKS25,35E
-

3MKS50E
FTKS20,25,35DW/L
FTKS20,25,35C
FVXS25,35F
FLKS25,35B
FDKS25,35E
-

FBQ35B8V1
(Height x Width x Depth)
Cooling
Cooling
Cooling

High/Low
High
High/Low

(Height x Width x Depth)


Cooling
Cooling
Cooling

High/Low
High/Low
High/Low

(Height x Width x Depth)


Cooling
Cooling
Cooling

H/M/L/SL
High
H/M/L/SL

mm
kg
m/min
dBA
dBA
Type

mm
kg
m/min
dBA
dBA
Type

mm
kg
m/min
dBA
dBA
Type

4MKS58E
4MKS75F
5MKS90E
FTKS20,25,35,50DW/L FTKS20,25,35,50DW/L FTKS20,25,35,50DW/L
FTKS20,25,35C/FTKS50F FTKS20,25,35C/FTKS50,60,71F FTKS20,25,35C/FTKS50,60,71F
FVXS25,35,50F
FVXS25,35,50F
FVXS25,35,50F
FLKS25,35,50B
FLKS25,35,50,60B
FLKS25,35,50,60B
FDKS25,35E/FDKS50C FDKS25,35E/FDKS50,60C FDKS25,35E/FDKS50,60C
FDBQ25B/FBQ35,50B FDBQ25B/FBQ35,50,60B FDBQ25B/FBQ35,50,60B
FFQ25,35,50B
FFQ25,35,50,60B
FFQ25,35,50,60B
FCQ35,50C
FCQ35,50,60C
FCQ35,50,60C
FHQ35,50B
FHQ35,50,60B
FHQ35,50,60B

FBQ50B8V1
300x700x800

30
11.5 / 9
52

31
14 / 10
53
33 / 29

FBQ60B8V1
300x1000x800
41
19 / 14
60
34 / 30

R-410A
1~/230V/50Hz

FCQ35C7VEB
204x840x840
19
10.0/8.5
49
31 / 27
R-410A
1~/220-240V/50/60Hz

FCQ50C7VEB
204x840x840
19
12.5/8.5
49
31 / 27
R-410A
1~/220-240V/50/60Hz

FDKS50CVMB
200x900x620
27.0
12.0 / 11.0 / 10.0 / 8.4
55.0
37.0 / 35.0 / 33.0 / 31.0

FDKS60CVMB
200x1100x620
30.0
16.0 / 14.8 / 13.5 / 11.2
56.0
38.0 / 36.0 / 34.0 / 32.0
R-410A
1~220-240/220-230V/50/60Hz

74

FCQ60C7VEB
204x840x840
19
13.5/8.5
51
33 / 28
R-410A
1~/220-240V/50/60Hz

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure
Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure
Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure
Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure
Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure
Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure
Refrigerant
Power Supply

FDKS25EAVMB
(Height x Width x Depth)
Cooling
Cooling
Cooling

H/M/L/SL
High
H/M/L/SL

FDKS35EAVMB

mm
kg
m/min
dBA
dBA
Type

200x700x620
21.0
8.7 / 8.0 / 7.3 / 6.2
53.0
35.0 / 33.0 / 31.0 / 29.0
R-410A
1~/220-240/220-230V/50/60Hz

FFQ25B8V1B
(Height x Width x Depth)
Cooling
Cooling
Cooling

High/Low
High
High/Low

mm
kg
m/min
dBA
dBA
Type

FFQ35B8V1B

9.0 / 6.5
46.5
29.5 / 24.5

10.0 / 6.5
49.0
32.0 / 25.0

Cooling
Cooling
Cooling

High/Low
High/Low
High/Low

mm
kg
m/min
dBA
dBA
Type

Cooling
Cooling
Cooling

H/M/L/SL
High
H/M/L/SL

mm
kg
m/min
dBA
dBA
Type

Cooling
Cooling
Cooling

H/M/L/SL
High
H/M/L/SL

24.0

25.0

53.0 / 48.0
37.0 / 32.0

54.0 / 49.0
38.0 / 33.0
R-410A
1~/220-240V/50Hz

FLKS35BAVMB

Cooling
Cooling
Cooling

H/M/L/SL
High
H/L/SL
H/M/L/SL

FLKS50BAVMB

FLKS60BAVMB

490x1050x200
16.0

17.0

7.60 / 6.80 / 6.00 / 5.2


53.0
37.0 / 34.0 / 31.0 / 28.0

8.60 / 7.60 / 6.6 / 5.6


54.0
38.0 / 35.0 / 32.0 / 29.0

11.40 / 10.00 / 8.50 / 7.5


63.0
47.0 / 43.0 / 39.0 / 36.0

12.00 / 10.70 / 9.30 / 8.3


64.0
48.0 / 45.0 / 41.0 / 39.0

R-410A
1~/220-240/220-230V/50/60Hz

mm
kg
m/min
dBA
dBA
Type

mm
kg
m/min
dBA
dBA
dBA
Type

FHQ60BVV1B
195x1160x680
27.0
17.0 / 13.0
55.0 / 49.0
39.0 / 33.0

13.0 / 10.0

FTKS25CAVMB
273x784x195
7.5

FTKS35CAVMB

7.70 / 5.90 / 4.20 / 3.60


56.0
38.0 / 32.0 / 25.0 / 22.0

7.70 / 6.00 / 4.40 / 3.80


57.0
39.0 / 33.0 / 26.0 / 23.0

R-410A
1~/220-240/220-230V/50/60Hz

FTKS20D3VML
(Height x Width x Depth)

15.0 / 10.0
58.0
41.0 / 32.0

FHQ50BVV1B

FTKS20CAVMB
(Height x Width x Depth)

12.0 / 8.0
53.0
36.0 / 27.0

195x960x680

FLKS25BAVMB
(Height x Width x Depth)

FFQ60B8V1B

R-410A
1~/230V/50Hz

FHQ35BVV1B
(Height x Width x Depth)

FFQ50B8V1B
286x575x575
17.5

FTKS25D3VML

FTKS35D3VML

FTKS50D2V1L

8.9 / 6.9 / 4.8 / 4.0


57.0
39.0 / 26.0 / 23.0

11.4 / 9.3 / 7.1 / 6.2


62.0
46.0 / 41.0 / 35.0 / 32.0

283x800x195
9.0
8.7 / 6.7 / 4.7 / 3.9
56.0
38.0 / 25.0 / 22.0
R-410A
1~/220-240/220-230V/50/60Hz

75

1~/220-240V/50Hz

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

FTKS20D3VMW
(Height x Width x Depth)
Cooling
Cooling
Cooling

H/M/L/SL
High
H/L/SL
H/M/L/SL

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure
Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure
Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure
Refrigerant
Power Supply

(Height x Width x Depth)


Cooling
Cooling
Cooling

H/M/L/SL
High
H/M/L/SL

(Height x Width x Depth)


Cooling
Cooling
Cooling

H/M/L/SL
Medium
H/M/L/SL

(Height x Width x Depth)


Cooling
Cooling
Cooling

H/L
H/L
H

mm
kg
m/min
dBA
dBA
dBA
Type

mm
kg
m/min
dBA
dBA
Type

mm
kg
m/min
dBA
dBA
Type

FTKS25D3VMW

mm
m
m

8.9 / 6.9 / 4.8 / 4.0


57.0
39.0 / 26.0 / 23.0

11.4 / 9.3 / 7.1 / 6.2


62.0
46.0 / 41.0 / 35.0 / 32.0

R-410A
1~220-240/220-230V/50/60Hz

220-240V/50Hz

FVXS25F

FVXS35F
600x700x210
14.0

FVXS50F

8.2 / 4.8 / 4.1


54.0
38.0 / 26.0 / 23.0

8.5 / 4.9 / 4.5


55.0
39.0 / 27.0 / 24.0
R-410A
1~/220-240V/50Hz

10.7 / 7.8 / 6.6


56.0
44.0 / 36.0 / 32.0

FTKS50FV1B

FTKS60FV1B
290x1050x238
12
16.2 / 13.6 / 11.4 / 10.2
61
45 / 41 / 36 / 33
R-410A
1~/220-240V/50Hz

FTKS71FV1B

14.7 / 12.4 / 10.3 / 9.5


59
43 / 39 / 34 / 31

17.4 / 14.6 / 11.6 / 10.6


62
46 / 42 / 37 / 34

FDBQ25B
230x652x502
17
6.5 / 5.2
35 / 28
55
R-410A
1~/220-240V/50Hz

mm
kg
m/min
dBA
dBA
Type

mm
kg
CDB
Type

FTKS50D2V1W

8.7 / 6.7 / 4.7 / 3.9


56.0
38.0 / 25.0 / 22.0

INVERTER
Outdoor Unit
Dimensions
(Height x Width x Depth)
Weight
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Piping Connections
Liquid (OD)/Gas
Piping Length (Maximum)
Max. internunit level difference

FTKS35D3VMW
283x800x195
9.0

2MKS40FV1B
2MKS50FV1B
550x765x285
550x765x285
38
42
+10~+46
+10~+46
R-410A
R-410A
1~/220-240V/50Hz
1~/220-240V/50Hz
6.35 / 9.52
6.35 / 12.7
30 (for total of each room), 20 (for one room) 30 (for total of each room), 20 (for one room)
7.5 (between indoor units) 7.5 (between indoor units)

76

3MKS550E,4MKS58E

3MKS50E2V1B
4MKS58E2V1B
735x936x300
49
-10.0~46.0
R-410A
1~/220-240V/50Hz
6.35 / 18
50 (for total of each room)/25 (for 1 room)
15.0 (between indoor units)

5MKS90E

4MKS75F2V1B
5MKS90E7V3B
735x936x300
770x900x320
57
69
-10~+46
-10.0~46.0
R-410A
R-410A
1~/220-240V/50Hz
1~/220-240V/50Hz
6.35 / 12.7 / 15.9
6.35 / 15.9 / 25
60 (for total of each room), 25 (for one room) 75(for total of each room)/25 (for 1 room)
15.0 (between indoor units) 7.5(between indoor units)

MXS-E/F
Multi model application
Inverter controlled

CONNECTABLE INDOOR UNITS


2MXS40F
FTXG25,35E
FTXS20,25,35DW/L
FTXS20,25,35C
FVXS25,35F
FLXS25,35B
FDXS25,35E
-

Stylish wall mounted unit


Wall mounted unit
Wall mounted unit
Floor standinig unit
Flexi type unit
Slim concealed ceiling unit
Concealed ceiling unit
4-way blow ceiling mounted cassette (600x600)
Round flow cassette
Ceiling suspended cassette

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

CTXG50EV1BW
(Height x Width x Depth)
Cooling
Heating
Cooling
Heating
Cooling
Heating

H/M/L/SL
H/M/L/SL
High
High
H/M/L/SL
H/M/L/SL

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate

Sound Power
Sound Pressure

Cooling
Heating
Cooling
Heating
Cooling
Heating

High/Low
High
High/Low
High
High
High/Low
High/Low

Sound Power
Sound Pressure
Refrigerant
Power Supply

(Height x Width x Depth)


Cooling
Heating
Cooling
Heating

H/L
H/L
H/L
H/L

mm
kg
m/min
m/min
m/min
dBA
dBA
dBA
dBA
Type

mm
kg
m/min
m/min
dBA
dBA
Type

5MXS90E
FTXG25,35E/CTXG50E
FTXS20,25,35,50DW/L
FTXS20,25,35C/FTXS50,60,71F
FVXS25,35,50F
FLXS25,35,50,60B
FDXS25,35E/FDXS50,60C
FDBQ25B/FBQ35,50,60B
FFQ25,35,50,60B
FCQ35,50,60C
FHQ35,50,60B

CTXG50EV1BS

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

275x840x150
9.0
11.3 / 9.1 / 7.1 / 6.7
12.6 / 10.6 / 8.7 / 7.7
64.0
64.0
47.0 / 41.0 / 35.0 / 32.0
47.0 / 41.0 / 35.0 / 32.0
R-410A
1~/220-240V/50Hz

FBQ35B8V1
(Height x Width x Depth)

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate

2MXS50F
3MXS52E
4MXS68F
4MXS80E
FTXG25,35E
FTXG25,35E/CTXG50E FTXG25,35E/CTXG50E FTXG25,35E/CTXG50E
FTXS20,25,35DW/L
FTXS20,25,35DW/L
FTXS20,25,35,50DW/L FTXS20,25,35,50DW/L
FTXS20,25,35C
FTXS20,25,35C/FTXS50F FTXS20,25,35C/FTXS50,60F FTXS20,25,35C/FTXS50,60,71F
FVXS25,35,50F
FVXS25,35,50F
FVXS25,35,50F
FVXS25,35,50F
FLXS25,35,50B
FLXS25,35,50B
FLXS25,35,50,60B
FLXS25,35,50,60B
FDXS25,35E/FDXS50C FDXS25,35E/FDXS50C FDXS25,35E/FDXS50,60C FDXS25,35E/FDXS50,60C
FDBQ25B/FBQ35,50B FDBQ25B/FBQ35,50,60B FDBQ25B/FBQ35,50,60B
FFQ25,35,50B
FFQ25,35,50,60B
FFQ25,35,50,60B
FCQ35,50C
FCQ35,50,60C
FCQ35,50,60C
FHQ35,50B
FHQ35,50,60B
FHQ35,50,60B

FBQ50B8V1
300x700x800

30
11.5 / 9

31
14 / 10
14 / 10
53
53

11.5 / 9
52
52
33 / 29
33 / 29

FBQ60B8V1
300x1000x800
41
19 / 14
19 / 14
60
60
34 / 30
34 / 30

R-410A
1~/230V/50Hz

FCQ35C7VEB
204x840x840
19
10.8 / 8.5
12.5 / 10.0
49
31 / 27
R-410A
1~/220-240V/50/60Hz

FCQ50C7VEB
204x840x840
19
12.5 / 8.5
12.5 / 8.5
49
31 / 27
R-410A
1~/220-240V/50/60Hz

77

FCQ60C7VEB
204x840x840
19
13.5 / 8.5
13.5 / 8.5
51
33 / 28
R-410A
1~/220-240V/50/60Hz

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

(Height x Width x Depth)


Cooling
Heating
Cooling
Heating
Cooling
Heating

H/M/L/SL
H/M/L/SL
High
High
H/M/L/SL
H/M/L/SL

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

Sound Power
Sound Pressure

Cooling
Heating
Cooling
Heating
Cooling
Heating

H/M/L/SL
H/M/L/SL
High
High
H/M/L/SL
H/M/L/SL

Sound Power
Sound Pressure

Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High
High/Low
High/Low

Sound Power
Sound Pressure
Refrigerant
Power Supply

FDXS35EAVMB

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

200x700x620
21.0
8.7 / 8.0 / 7.3 / 6.2
8.7 / 8.0 / 7.3 / 6.2
53.0
53.0
35.0 / 33.0 / 31.0 / 29.0
35.0 / 33.0 / 31.0 / 29.0
R-410A
1~/220-240/220-230V/50/60Hz

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

FFQ35B8V1B

Cooling
Heating
Cooling
Heating
Cooling
Heating

High/Low
High/Low
High/Low
High/Low
High/Low
High/Low

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

9.0 / 6.5
9.0 / 6.5
46.5
29.5 / 24.5
29.5 / 24.5

10.0 / 6.5
10.0 / 6.5
49.0
32.0 / 25.0
32.0 / 25.0

Cooling
Heating
Cooling
Heating
Cooling
Heating

H/M/L/SL
H/M/L/SL
High
High
H/M/L/SL
H/M/L/SL

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

FFQ60B8V1B

12.0 / 8.0
12.0 / 8.0
53.0
36.0 / 27.0
36.0 / 27.0

15.0 / 10.0
15.0 / 10.0
58.0
41.0 / 32.0
41.0 / 32.0

R-410A
1~/230V/50Hz

FHQ50BVV1B

FHQ60BVV1B
195x1160x680
27.0
17.0 / 13.0
16.0 / 13.0
55.0 / 49.0
55.0 / 49.0
39.0 / 33.0
39.0 / 33.0

195x960x680
24.0

25.0
13.0 / 10.0
13.0 / 10.0

53.0 / 48.0
53.0 / 48.0
37.0 / 32.0
37.0 / 32.0

54.0 / 49.0
54.0 / 49.0
38.0 / 33.0
38.0 / 33.0
R-410A
1~/220-240V/50Hz

FLXS25BAVMB
(Height x Width x Depth)

FFQ50B8V1B
286x575x575
17.5

FHQ35BVV1B
(Height x Width x Depth)

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate

R-410A
1~/220-240/220-230V/50/60Hz

FFQ25B8V1B
(Height x Width x Depth)

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate

FDXS60CVMB
200x1100x620
30.0
16.0 / 14.8 / 13.5 / 11.2
16.0 / 14.8 / 13.5 / 11.2
56.0
56.0
38.0 / 36.0 / 34.0 / 32.0
38.0 / 36.0 / 34.0 / 32.0

FDXS25EAVMB
(Height x Width x Depth)

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate

FDXS50CVMB
200x900x620
27.0
12.0 / 11.0 / 10.0 / 8.4
12.0 / 11.0 / 10.0 / 8.4
55.0
55.0
37.0 / 35.0 / 33.0 / 31.0
37.0 / 35.0 / 33.0 / 31.0

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

FLXS35BAVMB

FLXS50BAVMB

FLXS60BAVMB

490x1050x200
16.0
7.60 / 6.80 / 6.00 / 5.2
9.20 / 8.30 / 7.40 / 6.6
53.0

17.0
8.60 / 7.60 / 6.60 / 5.6
9.80 / 8.90 / 8.00 / 7.2
54.0

37.0 / 34.0 / 31.0 / 28.0


37.0 / 34.0 / 31.0 / 29.0

38.0 / 35.0 / 32.0 / 29.0


39.0 / 36.0 / 33.0 / 30.0

11.40 / 10.00 / 8.50 / 7.6


12.1 / 9.8 / 7.5 / 6.8
63.0
62.0
47.0 / 43.0 / 39.0 / 36.0
46.0 / 41.0 / 35.0 / 33.0

R-410A
1~/220-240/220-230V/50/60Hz

78

12.00 / 10.70 / 9.30 / 8.3


12.80 / 10.60 / 8.40 / 7.5
64.0
63.0
48.0 / 45.0 / 41.0 / 39.0
47.0 / 42.0 / 37.0 / 34.0

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

FTXG25EV1BW
(Height x Width x Depth)
Cooling
Heating
Cooling
Heating
Cooling
Heating

H/M/L/SL
H/M/L/SL
High
High
H/M/L/SL
H/M/L/SL

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

Sound Power
Sound Pressure

Cooling
Heating
Cooling
Heating
Cooling
Heating

H/M/L/SL
H/M/L/SL
High
High
H/M/L/SL
H/M/L/SL

Cooling
Heating
Cooling
Heating
Cooling

H/M/L/SL
H/M/L/SL
High
High
H/L/SL
H/M/L/SL
H/L/SL
H/M/L/SL

Refrigerant
Power Supply

Sound Power
Sound Pressure

Cooling
Heating
Cooling
Heating
Cooling
Heating

Refrigerant
Power Supply

7.7 / 6.1 / 4.7 / 3.8


9.0 / 7.9 / 6.7 / 5.4
56.0
56.0
38.0 / 32.0 / 25.0 / 22.0
38.0 / 33.0 / 28.0 / 25.0

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

8.1 / 6.5 / 4.9 / 4.1


9.6 / 8.2 / 6.7 / 5.9
57.0
57.0
39.0 / 33.0 / 26.0 / 23.0
39.0 / 34.0 / 29.0 / 29.0

FTXS25CAVMB
273x784x195
7.5

H/M/L/SL
H/M/L/SL
High
High
H/L/SL
H/M/L/SL
H/L/SL
H/M/L/SL

FTXS35CAVMB

7.70 / 5.90 / 4.20 / 3.60


7.80 / 6.50 / 5.30 / 4.60
56.0
56.0
38.0 / 32.0 / 25.0 / 22.0
38.0 / 33.0 / 28.0 / 25.0

7.70 / 6.00 / 4.40 / 3.80


8.10 / 6.70 / 5.30 / 4.60
57.0
57.0
39.0 / 33.0 / 26.0 / 23.0
39.0 / 34.0 / 29.0 / 26.0

R-410A
1~/220-240/220-230V/50/60Hz

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
dBA
dBA
Type

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
dBA
dBA
Type

FTXG35EV1BS

R-410A
1~/220-240V/50Hz

FTXS25D3VML

FTXS35D3VML

FTXS50D2V1L

8.9 / 6.9 / 4.8 / 4.0


9.7 / 7.9 / 6.0 / 5.2
57.0
57.0
39.0 / 26.0 / 23.0

11.4 / 9.3 / 7.1 / 6.2


11.4 / 9.4 / 7.4 / 6.3
62.0
62.0
46.0 / 41.0 / 35.0 / 32.0
46.0 / 40.0 / 34.0 / 31.0

283x800x195
9.0
8.7 / 6.7 / 4.7 / 3.9
9.4 / 7.6 / 5.8 / 5.0
56.0
56.0
38.0 / 25.0 / 22.0
38.0 / 28.0 / 25.0

39.0 / 29.0 / 26.0


-

R-410A
1~/220-240/220-230V/50/60Hz

FTXS20D3VMW
(Height x Width x Depth)

FTXG35EV1BW
275x840x150
9.0

FTXS20D3VML
(Height x Width x Depth)

Heating

Indoor Units
Dimensions
Weight
Air Flow Rate

FTXG25EV1BS

FTXS20CAVMB
(Height x Width x Depth)

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

FTXS25D3VMW

1~/220-240V/50Hz

FTXS35D3VMW

FTXS50D2V1W

8.9 / 6.9 / 4.8 / 4.0


9.7 / 7.9 / 6.0 / 5.2
57.0
57.0
39.0 / 26.0 / 23.0

11.4 / 9.3 / 7.1 / 6.2


11.4 / 9.4 / 7.4 / 6.3
62.0
62.0
46.0 / 41.0 / 35.0 / 32.0
46.0 / 40.0 / 34.0 / 31.0

283x800x195
9.0
8.7 / 6.7 / 4.7 / 3.9
9.4 / 7.6 / 5.8 / 5.0
56.0
56.0
38.0 / 25.0 / 22.0
38.0 / 28.0 / 25.0

39.0 / 29.0 / 26.0


R-410A
1~/220-240/220-230V/50/60Hz

1~/220-240/220-230V/50/60Hz

79

1~/220-240V/50Hz

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

FVXS25F
(Height x Width x Depth)
Cooling
Heating
Cooling
Heating
Cooling
Heating

H/L/SL
H/L/SL
High
High
H/L/SL
H/L/SL

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Pressure
Sound Power
Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

(Height x Width x Depth)


Cooling
Cooling
Heating
Cooling

H/L/SL
High
High
H/L/SL

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

FVXS35F
600x700x210
14.0
8.5 / 4.9 / 4.5
9.4 / 5.2 / 4.7
55
55
37 / 27 / 24
37 / 27 / 24
R-410A
1~/220-240V/50Hz

8.2 / 4.8 / 4.1


8.8 / 5.0 / 4.4
54
54
38 / 26 / 23
38 / 26 / 23

Cooling
Heating
Cooling
Heating
Cooling
Heating

H/M/L/SL
H/M/L/SL
Medium
Medium
H/M/L/SL
H/M/L/SL

Refrigerant
Power Supply

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

FTXS60FV1B
290x1050x238
12
16.2 / 13.6 / 11.4 / 10.2
17.4 / 15.1 / 12.7 / 11.4
61
60
45 / 41 / 36 / 33
44 / 40 / 35 / 32
R-410A
1~/220-240V/50Hz

14.7 / 12.4 / 10.3 / 9.5


16.1 / 13.9 / 11.5 / 10.2
59
58
43 / 39 / 34 / 31
42 / 38 / 33 / 30

INVERTER
Outdoor Unit
Dimensions
Weight
Operation Range

(Height x Width x Depth)


Cooling
Heating

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas
Piping Length (Maximum)
Max. internunit level difference

Min~Max
Min~Max

mm
kg
CDB
CWB
Type
mm
m
m

10.7 / 7.8 / 6.6


11.8 / 8.5 / 7.1
56
57
44 / 36 / 32
44 / 36 / 32

FDBQ25B
230x652x502
17
6.5 / 5.2
35 / 28
35 / 29
55
R-410A
1~/220-240V/50Hz

mm
kg
m/min
dBA
dBA
dBA
Type

FTXS50FV1B
(Height x Width x Depth)

FVXS50F

3MXS552E

FTXS71FV1B

17.4 / 14.6 / 11.6 / 10.6


19.7 / 16.9 / 14.3 / 12.7
62
62
46 / 42 / 37 / 34
46 / 42 / 37 / 34

4MXS80E, 5MXS90E

2MXS40FV1B
2MXS50FV1B
3MXS52E2V1B
4MXS68F2V1B
4MXS80E7V3B
5MXS90E7V3B
550x765x285
550x765x285
735x936x300
735x936x300
770x900x320
38
42
49
58
72
73
+10~+46
10~46
-10.0~46.0
-10~+46
-10.0~46.0
-10~+15.5
-15~15.5
-15~15.5
-15~+15.5
-15~15.5
R-410A
R-410A
R-410A
R-410A
R-410A
1~/220-240V/50Hz
1~/220-240V/50Hz
1~/230V/50Hz
1~/220-240V/50Hz
1~/230V/50Hz
6.35 / 9.52
6.35 / 12.7
6.35 / 18
6.35 / 9.52 / 12.7
6.35 / 15.9 / 25
30 (for total of each room)/ 20 (for one room) 30 (for total of each room)/ 20 (for one room) 50 (for total of each room)/ 25 (for one room) 60 (for total of each room), 25 (for one room) 70 (for total of each room)/ 25 (for one room) 75 (for total of each room)/ 25 (for one room)
7.5 (between indoor units) 7.5 (between indoor units) 7.5 (between indoor units) 7.5 (between indoor units)
7.5 (between indoor units)

80

RMXS - E
Super multi plus

CONNECTABLE INDOOR UNITS


20 class
FTXS20DW/L
FTXS20C
-

Stylish wall mounted unit


Wall mounted unit
Wall mounted unit
Floor standinig unit
Flexi type unit
Slim concealed ceiling unit
Concealed ceiling unit
4-way blow ceiling mounted cassette (600x600)
Round flow cassette
Ceiling suspended cassette

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

Sound Power
Sound Pressure

Cooling
Heating
Cooling
Heating
Cooling
Heating

H/M/L/SL
H/M/L/SL
High
High
H/M/L/SL
H/M/L/SL

Sound Power
Sound Pressure
Refrigerant
Power Supply

50 class
CTXG50E
FTXS50DW/L
FTXS50F
FVXS50F
FLXS50B
FDXS50C
FBQ50B
FFQ50B
FCQ50C
FHQ50B

Cooling
Heating
Cooling
Heating
Cooling
Heating

High/Low
High
High/Low
High
High
High/Low
High/Low

(Height x Width x Depth)


Cooling
Heating
Cooling
Heating

H/L
H/L
H/L
H/L

mm
kg
m/min
m/min
m/min
dBA
dBA
dBA
dBA
Type

mm
kg
m/min
m/min
dBA
dBA
Type

60 class
FTXS60F
FLXS60B
FDXS60C
FBQ60B
FFQ60B
FCQ60C
FHQ60B

71 class
FTXS71F
-

CTXG50EV1BS

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

275x840x150
9.0
11.3 / 9.1 / 7.1 / 6.7
12.6 / 10.6 / 8.7 / 7.7
64.0
64.0
47.0 / 41.0 / 35.0 / 32.0
47.0 / 41.0 / 35.0 / 32.0
R-410A
1~/220-240V/50Hz

FBQ35B8V1
(Height x Width x Depth)

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate

35 class
FTXG35E
FTXS35DW/L
FTXS35C
FVXS35F
FLXS35B
FDXS35E
FBQ35B
FFQ35B
FCQ35C
FHQ35B

CTXG50EV1BW
(Height x Width x Depth)

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate

25 class
FTXG25E
FTXS25DW/L
FTXS25C
FVXS25F
FLXS25B
FDXS25E
FDBQ25B
FFQ25B
-

FBQ50B8V1
300x700x800

30
11.5 / 9

31
14 / 10
14 / 10
53
53

11.5 / 9
52
52
33 / 29
33 / 29

FBQ60B8V1
300x1000x800
41
19 / 14
19 / 14
60
60
34 / 30
34 / 30

R-410A
1~/230V/50Hz

FCQ35C7VEB
204x840x840
19
10.8 / 8.5
12.5 / 10.0
49
31 / 27
R-410A
1~/220-240V/50/60Hz

FCQ50C7VEB
204x840x840
19
12.5 / 8.5
12.5 / 8.5
49
31 / 27
R-410A
1~/220-240V/50/60Hz

81

FCQ60C7VEB
204x840x840
19
13.5 / 8.5
13.5 / 8.5
51
33 / 28
R-410A
1~/220-240V/50/60Hz

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

(Height x Width x Depth)


Cooling
Heating
Cooling
Heating
Cooling
Heating

H/M/L/SL
H/M/L/SL
High
High
H/M/L/SL
H/M/L/SL

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

Sound Power
Sound Pressure

Cooling
Heating
Cooling
Heating
Cooling
Heating

H/M/L/SL
H/M/L/SL
High
High
H/M/L/SL
H/M/L/SL

Sound Power
Sound Pressure

Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High
High/Low
High/Low

Sound Power
Sound Pressure
Refrigerant
Power Supply

FDXS35EAVMB

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

200x700x620
21.0
8.7 / 8.0 / 7.3 / 6.2
8.7 / 8.0 / 7.3 / 6.2
53.0
53.0
35.0 / 33.0 / 31.0 / 29.0
35.0 / 33.0 / 31.0 / 29.0
R-410A
1~/220-240/220-230V/50/60Hz

mm
kg
m/min
m/min
dBA
dBA
dBA
Type

FFQ35B8V1B

Cooling
Heating
Cooling
Heating
Cooling
Heating

High/Low
High/Low
High/Low
High/Low
High/Low
High/Low

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

9.0 / 6.5
9.0 / 6.5
46.5
29.5 / 24.5
29.5 / 24.5

10.0 / 6.5
10.0 / 6.5
49.0
32.0 / 25.0
32.0 / 25.0

Cooling
Heating
Cooling
Heating
Cooling
Heating

H/M/L/SL
H/M/L/SL
High
High
H/M/L/SL
H/M/L/SL

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

FFQ60B8V1B

12.0 / 8.0
12.0 / 8.0
53.0
36.0 / 27.0
36.0 / 27.0

15.0 / 10.0
15.0 / 10.0
58.0
41.0 / 32.0
41.0 / 32.0

R-410A
1~/230V/50Hz

FHQ50BVV1B

FHQ60BVV1B
195x1160x680
27.0
17.0 / 13.0
16.0 / 13.0
55.0 / 49.0
55.0 / 49.0
39.0 / 33.0
39.0 / 33.0

195x960x680
24.0

25.0
13.0 / 10.0
13.0 / 10.0

53.0 / 48.0
53.0 / 48.0
37.0 / 32.0
37.0 / 32.0

54.0 / 49.0
54.0 / 49.0
38.0 / 33.0
38.0 / 33.0
R-410A
1~/220-240V/50Hz

FLXS25BAVMB
(Height x Width x Depth)

FFQ50B8V1B
286x575x575
17.5

FHQ35BVV1B
(Height x Width x Depth)

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate

R-410A
1~/220-240/220-230V/50/60Hz

FFQ25B8V1B
(Height x Width x Depth)

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate

FDXS60CVMB
200x1100x620
30.0
16.0 / 14.8 / 13.5 / 11.2
16.0 / 14.8 / 13.5 / 11.2
56.0
56.0
38.0 / 36.0 / 34.0 / 32.0
38.0 / 36.0 / 34.0 / 32.0

FDXS25EAVMB
(Height x Width x Depth)

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate

FDXS50CVMB
200x900x620
27.0
12.0 / 11.0 / 10.0 / 8.4
12.0 / 11.0 / 10.0 / 8.4
55.0
55.0
37.0 / 35.0 / 33.0 / 31.0
37.0 / 35.0 / 33.0 / 31.0

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

FLXS35BAVMB

FLXS50BAVMB

FLXS60BAVMB

490x1050x200
16.0
7.60 / 6.80 / 6.00 / 5.2
9.20 / 8.30 / 7.40 / 6.6
53.0

17.0
8.60 / 7.60 / 6.60 / 5.6
9.80 / 8.90 / 8.00 / 7.2
54.0

37.0 / 34.0 / 31.0 / 28.0


37.0 / 34.0 / 31.0 / 29.0

38.0 / 35.0 / 32.0 / 29.0


39.0 / 36.0 / 33.0 / 30.0

11.40 / 10.00 / 8.50 / 7.6


12.1 / 9.8 / 7.5 / 6.8
63.0
62.0
47.0 / 43.0 / 39.0 / 36.0
46.0 / 41.0 / 35.0 / 33.0

R-410A
1~/220-240/220-230V/50/60Hz

82

12.00 / 10.70 / 9.30 / 8.3


12.80 / 10.60 / 8.40 / 7.5
64.0
63.0
48.0 / 45.0 / 41.0 / 39.0
47.0 / 42.0 / 37.0 / 34.0

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

FTXG25EV1BW
(Height x Width x Depth)
Cooling
Heating
Cooling
Heating
Cooling
Heating

H/M/L/SL
H/M/L/SL
High
High
H/M/L/SL
H/M/L/SL

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

Sound Power
Sound Pressure

Cooling
Heating
Cooling
Heating
Cooling
Heating

H/M/L/SL
H/M/L/SL
High
High
H/M/L/SL
H/M/L/SL

Cooling
Heating
Cooling
Heating
Cooling

H/M/L/SL
H/M/L/SL
High
High
H/L/SL
H/M/L/SL
H/L/SL
H/M/L/SL

Refrigerant
Power Supply

Sound Power
Sound Pressure

Cooling
Heating
Cooling
Heating
Cooling
Heating

Refrigerant
Power Supply

7.7 / 6.1 / 4.7 / 3.8


9.0 / 7.9 / 6.7 / 5.4
56.0
56.0
38.0 / 32.0 / 25.0 / 22.0
38.0 / 33.0 / 28.0 / 25.0

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

8.1 / 6.5 / 4.9 / 4.1


9.6 / 8.2 / 6.7 / 5.9
57.0
57.0
39.0 / 33.0 / 26.0 / 23.0
39.0 / 34.0 / 29.0 / 29.0

FTXS25CAVMB
273x784x195
7.5

H/M/L/SL
H/M/L/SL
High
High
H/L/SL
H/M/L/SL
H/L/SL
H/M/L/SL

FTXS35CAVMB

7.70 / 5.90 / 4.20 / 3.60


7.80 / 6.50 / 5.30 / 4.60
56.0
56.0
38.0 / 32.0 / 25.0 / 22.0
38.0 / 33.0 / 28.0 / 25.0

7.70 / 6.00 / 4.40 / 3.80


8.10 / 6.70 / 5.30 / 4.60
57.0
57.0
39.0 / 33.0 / 26.0 / 23.0
39.0 / 34.0 / 29.0 / 26.0

R-410A
1~/220-240/220-230V/50/60Hz

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
dBA
dBA
Type

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
dBA
dBA
Type

FTXG35EV1BS

R-410A
1~/220-240V/50Hz

FTXS25D3VML

FTXS35D3VML

FTXS50D2V1L

8.9 / 6.9 / 4.8 / 4.0


9.7 / 7.9 / 6.0 / 5.2
57.0
57.0
39.0 / 26.0 / 23.0

11.4 / 9.3 / 7.1 / 6.2


11.4 / 9.4 / 7.4 / 6.3
62.0
62.0
46.0 / 41.0 / 35.0 / 32.0
46.0 / 40.0 / 34.0 / 31.0

283x800x195
9.0
8.7 / 6.7 / 4.7 / 3.9
9.4 / 7.6 / 5.8 / 5.0
56.0
56.0
38.0 / 25.0 / 22.0
38.0 / 28.0 / 25.0

39.0 / 29.0 / 26.0


-

R-410A
1~/220-240/220-230V/50/60Hz

FTXS20D3VMW
(Height x Width x Depth)

FTXG35EV1BW
275x840x150
9.0

FTXS20D3VML
(Height x Width x Depth)

Heating

Indoor Units
Dimensions
Weight
Air Flow Rate

FTXG25EV1BS

FTXS20CAVMB
(Height x Width x Depth)

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

FTXS25D3VMW

1~/220-240V/50Hz

FTXS35D3VMW

FTXS50D2V1W

8.9 / 6.9 / 4.8 / 4.0


9.7 / 7.9 / 6.0 / 5.2
57.0
57.0
39.0 / 26.0 / 23.0

11.4 / 9.3 / 7.1 / 6.2


11.4 / 9.4 / 7.4 / 6.3
62.0
62.0
46.0 / 41.0 / 35.0 / 32.0
46.0 / 40.0 / 34.0 / 31.0

283x800x195
9.0
8.7 / 6.7 / 4.7 / 3.9
9.4 / 7.6 / 5.8 / 5.0
56.0
56.0
38.0 / 25.0 / 22.0
38.0 / 28.0 / 25.0

39.0 / 29.0 / 26.0


R-410A
1~/220-240/220-230V/50/60Hz

1~/220-240/220-230V/50/60Hz

83

1~/220-240V/50Hz

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

FVXS25F
(Height x Width x Depth)
Cooling
Heating
Cooling
Heating
Cooling
Heating

H/L/SL
H/L/SL
High
High
H/L/SL
H/L/SL

Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Pressure
Sound Power
Refrigerant
Power Supply

Indoor Units
Dimensions
Weight
Air Flow Rate
Sound Power
Sound Pressure

(Height x Width x Depth)


Cooling
Cooling
Heating
Cooling

H/L/SL
High
High
H/L/SL

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

FVXS35F
600x700x210
14.0
8.5 / 4.9 / 4.5
9.4 / 5.2 / 4.7
55
55
37 / 27 / 24
37 / 27 / 24
R-410A
1~/220-240V/50Hz

8.2 / 4.8 / 4.1


8.8 / 5.0 / 4.4
54
54
38 / 26 / 23
38 / 26 / 23

Cooling
Heating
Cooling
Heating
Cooling
Heating

H/M/L/SL
H/M/L/SL
Medium
Medium
H/M/L/SL
H/M/L/SL

Refrigerant
Power Supply

mm
kg
m/min
m/min
dBA
dBA
dBA
dBA
Type

FTXS60FV1B
290x1050x238
12
16.2 / 13.6 / 11.4 / 10.2
17.4 / 15.1 / 12.7 / 11.4
61
60
45 / 41 / 36 / 33
44 / 40 / 35 / 32
R-410A
1~/220-240V/50Hz

14.7 / 12.4 / 10.3 / 9.5


16.1 / 13.9 / 11.5 / 10.2
59
58
43 / 39 / 34 / 31
42 / 38 / 33 / 30

Heat Pump
Outdoor Unit
Dimensions
Weight
Operation Range

FTXS71FV1B

17.4 / 14.6 / 11.6 / 10.6


19.7 / 16.9 / 14.3 / 12.7
62
62
46 / 42 / 37 / 34
46 / 42 / 37 / 34

INVERTER
RMXS112E7V3B1

(Height x Width x Depth)


Cooling
Heating

10.7 / 7.8 / 6.6


11.8 / 8.5 / 7.1
56
57
44 / 36 / 32
44 / 36 / 32

FDBQ25B
230x652x502
17
6.5 / 5.2
35 / 28
35 / 29
55
R-410A
1~/220-240V/50Hz

mm
kg
m/min
dBA
dBA
dBA
Type

FTXS50FV1B
(Height x Width x Depth)

FVXS50F

Min~Max
Min~Max

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Max. internunit level difference

RMXS140E7V3B1
1345x900x320
125
-5~46
-15~20
R-410A
9,52 / 19,1 / 26x3
15

mm
kg
CDB
CWB
Type
mm
m

84

RMXS160E7V3B1

ERYQ
EKHBH/EKHBX
EKSWW
The Altherma air
to water heat pump

ERYQ005-007AC
6C - 0M - 0Y - 61K

34C - 11M - 0Y - 0K

0C - 0M - 71Y - 0K

EKHBH/EKHBX007AC

EKSWW200V3

20C - 97M - 41Y - 6K

The Altherma air to water heat pump is todays answer to the current and future problems
associated with conventional heating systems, namely, increasing primary energy costs and
an unacceptably high environmental impact
Cost effective alternative to a fossil fuel boiler
Altherma is a comparable alternative to a conventional fossil fuel boiler and optimises the inherently clean, reliable and
low maintenance characteristics of heat pump technology.
Low energy bills and low CO2 emissions
Conventional fuels are becoming scarcer and ever more expensive. As these costs increase, the most attractive renewable
source heating system is an air to water heat pump which, by the use of the free heat in the outside air, is at least
three times more efficient when compared to a fossil fuel boiler. The result is low primary energy use and no direct CO2
emissions.
Easy to install
The compact outdoor unit can be located where convenient and requires no drilling or excavation work to collect heat.
The indoor hydro-box does not require a dedicated technical room, or additional infrastructure, such as chimneys, fuel
tanks or gas connections. Altherma can be connected to industry standard low temperature radiators and underfloor
heating systems and can be configured for use in both new and refurbishment applications.
Total solution for year round comfort
Altherma is designed to provide for your sanitary hot water needs all year round and can be selected with a cooling
option for the hot summer months. The use of Daikins advanced inverter technology and variable set-point temperature
ensures accurate and stable room temperatures at all times and the lowest possible energy consumption.

85

The system at a glance


Altherma is a split system consisting of an outdoor unit and an indoor hydro-box that can be connected to all standard
low temperature radiators and underfloor heating systems.

Outdoor unit
The outdoor unit extracts free low temperature heat from
the surrounding air and increases its temperature. Upgraded
heat is then transmitted via the refrigerant circuit to the
indoor hydro-box.

Sanitary hot
water tank
(optional)

Indoor hydro-box

Outdoor unit

Indoor hydro-box
The indoor hydro-box transfers the heat in the refrigerant
to the water circulated in the central heating radiators,
underfloor heating system and sanitary hot water tank. In the
combined heating & cooling version of the indoor hydro-box
cooling is achieved by reducing the water temperature to 5C
and circulating it through fan coil units. The system can also
provide moderate cooling via the underfloor heating system
or radiators by limiting the lowest water temperature. The
preparation of sanitary hot water is performed by switching
the system from cooling or heating to sanitary mode.

86

Sanitary hot water tank (optional)


A purpose built stainless steel water tank, constructed
to maintain the highest levels of energy efficiency,
is available to meet sanitary hot water needs. The
combination of an electric booster heater in the upper
part of the tank and a heat pump heat exchanger in
the lower part ensures the lowest possible energy
consumption with rapid water heating. In addition,
a built in function raises the water temperature to
70C or higher at least once a week to remove any
possibility of legionella growth.

Typical system
configuration including
optional sanitary
hot water tank and
optional cooling

System controls
System controls and the user interface are contained
within the hydro-box and feature a weekly timer
that enables the indoor temperature to be controlled
according to user requirements. The timer is
programmable on an hourly or daily basis so that
temperatures can be reduced at night or during
holidays and increased prior to rising in the morning
or returning home. User comfort according to
personal preference is thus maintained at all times.
Where control over individual room temperatures and
comfort levels is needed a conventional room
controller should be added.

87

Hydro-kit
Function
For use with
Dimensions
Leaving water temperature range

EKHBH007AC***

EKHBH016AC***

EKHBX007AC***

Heating only
HxWxD
heating
cooling

mm
C
C

ERYQ005~007
895 x 487 x 361

EKHBX016AC***

Heating and Cooling


ERYQ005~007
ERYQ011~016
936 x 487 x 461
936 x 502 x 361

ERYQ011~016
922 x 502 x 361
25~55
-

5~20
Yes
Polyester painted galvanised steel plate
RAL9010 (neutral white)

Drain valve
Material
Colour

5~22 (with EKHBP)

EKHB*007AC

*** Hydro Kit with Factory Mounted Electric Heater


Power Supply

Capacity and Steps

EKHBH007AC3V3
EKHBH007AC6V3
EKHBH007AC6W1
EKHBH007AC9W1
EKHBH016AA3V3
EKHBH016AA6V3
EKHBH016AA6WN
EKHBH016AA9WN

230V Single Phase


230V Single Phase
400V Three Phase and Neutral
400V Three Phase and Neutral
230V Single Phase
230V Single Phase
400V Three Phase and Neutral
400V Three Phase and Neutral

3kW 1 step
6kW 2 step
6kW 2 step
9kW 2 step
3kW 1 step
6kW 2 step
6kW 2 step
9kW 2 step

EKHBX007AC3V3
EKHBX007AC6V3
EKHBX007AC6W1
EKHBX007AC9W1
EKHBX016AA3V3
EKHBX016AA6V3
EKHBX016AA6WN
EKHBX016AA9WN

230V Single Phase


230V Single Phase
400V Three Phase and Neutral
400V Three Phase and Neutral
230V Single Phase
230V Single Phase
400V Three Phase and Neutral
400V Three Phase and Neutral

3kW 1 step
6kW 2 step
6kW 2 step
9kW 2 step
3kW 1 step
6kW 2 step
6kW 2 step
9kW 2 step

OPTIONAL DRAIN PAN

EKHBDP

For cooling operation below 18 C

Standard

Option

ERYQ005AC
Outdoor Unit
Dimensions
Nominal capacity
Nominal input
COP
EER
Operation range Outdoor Temperature
Sound pressure level
Weight
Refrigerant charge
Power supply
Recommended fuses
Piping connections

ERYQ005AC
HxWxD
heating
cooling
heating
cooling

mm
kW
kW
kW
kW

heating
cooling
hot water
heating
cooling
R-410A

C
C
C
dBA
dBA
kg
kg

liquid
gas
drain

A
mm
mm
mm

5.75
5.12
1.26
2.16
4.56
2.37

48
47

ERYQ006AC
735 x 825 x 300
6.84
5.86
1.58
2.59
4.34
2.26
-20 ~ 25
15 ~ 43
-20 ~ 43
48
47
56
1.7
220~240V Single Phase
20
Flare 6.35
Flare 15.9
1 x Hole 18mm

ERYQ007AC

ERHQ011AA

8.43
6.08
2.08
2.75
4.05
2.21

10.3
10
3.06
3.6
3.37
2.78

52
53

49
50

ERHQ014AA

ERHQ016AA

1170 x 900 x 320


13.1
12.5
3.88
5.29
3.38
2.36
-20 ~ 35
10 ~ 46
-20 ~ 43
51
52
103
3.7
220~240V Single Phase
32
Flare 9.52
Flare 15.9
3 x Hole 26mm

15.2
13.1
4.66
5.95
3.26
2.2

53
54

Nominal Capacity and Power Input based on the following conditions: Heating: Ambient 7C db 6C wb, Leaving Water Temp 35C (DT 5C) Cooling: Ambient 35C, Leaving Water Temp 7C

Domestic Hot Water Tank

EKSWWU150V3 EKSWWU200V3 EKSWWU300V3

Suitable For
Pressure / Temp Relief Valve included
Water Volume
Max water temperature
Height
Diameter
Electric Heater
Power supply
Material inside Tank
Material outside Tank
Colour
Weight

Unvented Systems (EKUSWW kit also required - see below)


Fitted
150
200
300
85
1015
1265
1715

ACCESSORY KIT FOR UNVENTED SYSTEMS


Items Included

litres
C
mm
mm
kW

kg

38

EKSWW150V3

EKSWW200V3

EKSWW300V3

150

Open vent systems


Not Supplied
200
85
1150

300

900
580
3
220~240V Single Phase
Stainless Steel
Mild Steel
Neutral White
60
37

46
EKUSWW

1. Combined Pressure Reducing Valve, non return valve,


strainer, expansion relief valve
2. Expansion Vessel
3. Primary circuit motorised shut off valve
4. Tundish
5. Draincock

88

1600

EKSWW(U)200V3
45
Not Applicable

59

ERX
Condensing units for
air handling applications (pair)
A new range of R-410A inverter condensing units for pair application with air handling units.




Inverter controlled units


Large capacity range (from 71 to 140 class)
Cooling only
R-410A
Flexible control possibilities:
- Control x:
control of air temperature (discharge temperature, suction temperature, room temperature) via
external device
(DDC controller)
- Control y:
control of evaporating temperature via Daikin control (no DDC controller needed)
- Control z:
control of air temperature (suction temperature, room temperature) via Daikin control (no DDC
controller needed)

Wide range of expansion valve kits available

Air handling unit


Liquid pipe

Liquid pipe

Gas pipe

Gas pipe

Expansion valve kit :


EKEXV kit

F1F2 communication

Control box :
EKEXDCB : control z
EKEXFCB : control x,y

DDC control
(control x)

89

(Field Supply)

cooling only
Outdoor unit
Dimensions
Weight
Sound pressure level
Sound power level
Operation range
Refrigerant type
Piping connections

ERX100AV3
HxWxD
cooling
cooling
cooling

nominal
nominal
min-max
liquid
gas
drain
min
max
max

Piping length
Installation height difference
Power supply

mm
kg
dB(A)
dB(A)
CDB

ERX125AV3
1,345x900x320
127
53
68
-5 ~ 46
R-410A
9.52

51
67

mm
mm
mm
m
m
m
V3

ERX140AV3

54
70

15.9

19.1
26x3
5
55
<
_ 30
1 ~, 230V, 50Hz

cooling only
Outdoor unit
Cooling capacity
Power input
EER
Casing
Dimensions
Weight
Operation Range
Sound level (nominal)
Refrigerant
Piping Connections

ERX125AW1
14.0
3.52
3.98

kW
kW
Colour
Material
Unit
Unit
Cooling
Sound power
Sound pressure
Type
Liquid
Gas

HxWxD
Min ~ Max

Diameter (OD)
Diameter (OD)

Power Supply

mm
kg
CDB
dB(A)
dB(A)

1680x635x765
157
-5.0~ 43.0
72
54
R-410A
9.52
15.9

mm
mm
W1

ERX250AW1
28.0
7.42
3.77

ERX200AW1
22.4
5.56
4.03
Daikin White
Painted galvanized steel plate
1680x930x765
185
-5.0~ 43.0
78
57
R-410A
9.52
19.1
3N~, 50Hz, 400V

1680x930x765
238
-5.0~ 43.0
78
58
R-410A
9.52
22.2

Combination table
Control box
control z

Outdoor unit

EKEXDCBA EKEXFCBA
1ph

3ph

Options

Expansion valve kit

control
x or y

class 63

class 80

class 100

class 125

class 140

class 200

class 250

Central
drain kit
KKPJ5F180

EKEXV63

EKEXV80

EKEXv100

EKEXV125

EKEXV140

EKEXV200

EKEXV250

ERX100AV3

ERX125AV3
ERX140AV3
ERX125AW1
ERX200AW1
ERX250AW1

P
P
P
P

P
P
P
P

P
P
-

P
P
P
-

P
P
P
P
-

P
P
P
P
P

P
P
P
P
P

P
P

P
P

X
X
-

P: Pair: Combination depending on air handling units coils volume.


x: Possibility to connect.

90

VRV air handling applications

new

A new range of R-410A inverter condensing


units for multi application with air handling
units.




Inverter controlled units


Large capacity range (from 5 to 18HP)
Cooling only
R-410A
Control z:
control of air temperature (suction
temperature, room temperature) via Daikin
control (no DDC controller needed)

Air handling unit


EXV-kit

Large range of expansion valve kits available


BRC1D52 is used to set the set point temperature

(Field
Supply)

(connected to the EKEXMCB).

EKEXMCB

gas pipe
liquid pipe
F1,F2 communication
Cooling only
RXQ-P
Capacity range
Capacity
Power input (Nominal)
Dimensions
Weight
Sound Level

Cooling
Cooling
(Height x Width x Depth)

Sound Power
Cooling
Sound Pressure Cooling
Air Flow Rate (nominal at 230V) Cooling
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Max n of indoor units to be connected
Piping connections
Liquid (OD)/Gas

HP
kw
kw
mm
kg
dBA
dBA
m/min
CDB

mm

5
5
14.0
3.52
1,680x635x765
157
72
54
95

8
8
22.4
5.56

10
10
28.0
7.42
1,680x930x765

57
171

58
185

8
9.5 / 15.9

13
9.5 / 19.1

16
9.5 / 22.2

185

12
12
33.5
9.62

14
14
40.0
12.4

238

16
16
45.0
14.2
1,680x1,240x765
315

78

323
83
63
239

80
60
196
-5.0~43.0
R-410A
3N~/400V/50Hz
19
12.7 / 22.2

233

23

18
18
49.0
16.2

26

29
15.9 / 28.6

12.7 / 28.6

Combination table
Control
box
Outdoor unit

3ph

Expansion valve kit

control z

class 50

class 63

class 80

class 100

class 125

class 140

class 200

class 250

EKEXMCB

EKEXV50

EKEXV63

EKEXV80

EKEXv100

EKEXV125

EKEXV140

EKEXV200

EKEXV250

RXQ5P

RXQ8P
RXQ10P
RXQ12P
RXQ14P
RXQ16P
RXQ18P

x
x
x
x
x
x

x
x
x
x
x
x

x
x
x
x
x
x

x
x
x
x
x
x

x
x
x
x
x
x

x
x
x
x
x
x

x
x
x
x
x
x

x
x
x
x
x
x

x
x
x
x
x
x

91

92

Rising energy and general building services running costs have led
end users to expect far more than just cooling and heating from their
air conditioning. A truly complete and acceptable system therefore,
must be energy efficient, economic to run, easy to install, flexible,
reliable and user friendly.
Fresh air must also be supplied without increasing energy consumption
and central management and control facilities have gained in
importance, particularly for medium to large sized buildings.
The Daikin Hi-VRV system meets all these requirements:
Air Conditioning

HRV

DAIKIN
NETWORK
SOLUTION

Ventilation

Control & Management

VRV air conditioning can be found in offices, restaurants, theatres,


hospitals, universities, museums, shops - in short, in any location
where the provision of a balanced, pleasant working environment
can improve the lifestyle and comfort of the individual.

VRVIII
RXYSQ4-6P7V3B
new RXYSQ4-6P7Y1B
RXQ5-18P7W1B(A)
RXYQ5-18P7W1B(A)
RXYQ20-36P7W1B(A)
RXYQ38-54P7W1B(A)
RXYQ16-36P7W1B
new REYQ18-48P7Y1B
VRVII
RWEYQ-MY1
INDOOR UNITS
1. Cassette units
new FXFQ-P7VEB
FXZQ-M8V1B
FXCQ-M8V3B
FXKQ-MAVE
2. Concealed ceiling units
FXDQ-M8V3B
FXDQ-P/NA
FXSQ-M8V3B
FXMQ-MAVE
3. Wall mounted units
FXAQ-MAVE
4. Ceiling suspended units
FXHQ-MAVE
FXUQ-MAV1
5. Floor standing units
FXNQ-MAVE
FXLQ-MAVE
6. Outdoor air processing unit
FXMQ-MFV1
HRV
VAM-FA
VKM-GA

93

94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118

RXYSQ4-6P7V3B
VRVIII-S Inverter heat pump

l
l
l
l
l
l
l

RXYSQ-P7V3B

High COP values


Maximum 9 indoor units per outdoor unit
Silent operation
Small capacities - 4, 5 & 6HP
Super wide range of indoor units
Slim & flexible design
Space saving outdoor unit

HEAT PUMP
Outdoor Unit
Capacity range
Capacity
Dimensions
Weight
Sound Level

Air Flow Rate (nominal


at 230V)
Operation Range

Cooling
Heating
(Height x Width x Depth)
Sound Power
Cooling
Sound Pressure Cooling
Heating
Cooling
Heating
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Max n of indoor units to be connected
Piping connections
Liquid (OD)/Gas/Drain
Max total length

HP
kw
kw
mm
kg
dBA
dBA
dBA
m/min
m/min
CDB
CWB

RXYSQ4P7V3B
4
11.2
12.5

RXYSQ5P7V3B
5
14.0
16.0
1,345x900x320
125
67
51
53
106

66
50
52
102

69
53
55
105

-5.0~46
-20~15.5
R-410A
1~/230V/50Hz
8

6
mm
m

RXYSQ6P7V3B
6
15.5
18.0

9.52 / 15.9 / 26 x 3
300

94

9
9.52 / 19.1 / 26 x 3

RXYSQ4-6P7Y1B
VRVIII-S Inverter heat pump

l
l
l
l
l
l
l

RXYSQ-P7Y1B

High COP values


Maximum 9 indoor units per outdoor unit
Silent operation
Small capacities - 4, 5 & 6HP
Super wide range of indoor units
Slim & flexible design
Space saving outdoor unit

HEAT PUMP
Outdoor Unit
Capacity range
Capacity
Dimensions
Weight
Sound Level

Air Flow Rate (nominal


at 230V)
Operation Range

Cooling
Heating
(Height x Width x Depth)
Sound Power
Cooling
Sound Pressure Cooling
Heating
Cooling
Heating
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Max n of indoor units to be connected
Piping connections
Liquid (OD)/Gas/Drain
Max total length

HP
kw
kw
mm
kg
dBA
dBA
dBA
m/min
m/min
CDB
CWB

RXYSQ4P7Y1B
4
11.2
12.5

RXYSQ5P7Y1B
5
14.0
16.0
1,345x900x320
120
67
51
53
106

66
50
52
102

69
53
55
105

-5.0~46
-20~15.5
R-410A
3~/280-415V/50Hz
8

6
mm
m

RXYSQ6P7Y1B
6
15.5
18.0

9.52 / 15.9 / 26 x 3
300

95

9
9.52 / 19.1 / 26 x 3

RXQ5-18P7W1B(A)

VRVIII inverter cooling only

l
l
l
l
l
l
l

l
l
l

RXQ5P

Wide range of indoor units: 13 different models in a


total of 75 variations
Compact size of outdoor units
Increased COP
2 steps in night quiet mode: eg. 10HP: 58 dBA, 1st
step: 54dBA, 2nd step: 45dBA
In line with RoHS
Easy combination with HRV
Connectable to current Daikin control systems: DSnet, Intelligent Touch Controller, Intelligent Manager,
BACnet Gateway, DMS-IF
Easy installation thanks to automatic refrigerant
charging operation, automatic test operation
Quiet operation
Leak detection function

RXQ8-12P

RXQ14-18P

Cooling only
RXQ-P(A)
Capacity range
Capacity
Power input (Nominal)
Dimensions
Weight
Sound Level

Cooling
Cooling
(Height x Width x Depth)

Sound Power
Cooling
Sound Pressure Cooling
Air Flow Rate (nominal at 230V) Cooling
Operation Range
Cooling
Min~Max
Refrigerant
Power Supply
Max n of indoor units to be connected
Piping connections
Liquid (OD)/Gas

HP
kw
kw
mm
kg
dBA
dBA
m/min
CDB

mm

5
5
14.0
3.52
1,680x635x765
157
72
54
95

8
8
22.4
5.56

10
10
28.0
7.42
1,680x930x765

57
171

58
185

8
9.5 / 15.9

13
9.5 / 19.1

16
9.5 / 22.2

185

12
12
33.5
9.62

14
14
40.0
12.4

238

314

78

96

16
16
45.0
14.2
1,680x1,240x765

322
83
63
239

80
60
196
-5.0~43.0
R-410A
3N~/400V/50Hz
19
12.7 / 28.6

233

23

26
12.7 / 28.6

18
18
49.0
16.2

29
15.9 / 28.6

RXYQ5-18P7W1B(A)
VRVIII Inverter heat pump
Small footprint combination

l
l
l

l
l
l
l
l
l
l

l
l
l

RXYQ5P

Increased outdoor unit capacity up to 54 HP


Wide range of indoor units: 13 different models in a
total of 75 variations
Flexible combination of outdoor units: small
footprint combination, high COP combination or any
other combination of your choice
Compact size of outdoor units
Increased COP
Increased external static pressure: up to 78.4Pa
2 steps in night quiet mode: eg. 10HP: 58 dBA, 1st
step: 54dBA, 2nd step: 45dBA
In line with RoHS
Easy combination with HRV
Connectable to current Daikin control systems: DSnet, Intelligent Touch Controller, Intelligent Manager,
BACnet Gateway, DMS-IF
Easy installation thanks to automatic refrigerant
charging operation, automatic test operation
Quiet operation
Leak detection function

RXYQ8-12P

RXYQ14-18P

Heat Pump
RXYQ-P(A)
Capacity range
Capacity
Power input (Nominal)
Dimensions
Weight
Sound Level
Air Flow Rate (nominal
at 230V)
Operation Range

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Sound Power
Sound Pressure
Cooling
Heating
Cooling
Heating

Refrigerant
Power Supply
Max n of indoor units to be connected
Piping connections
Liquid (OD)/Gas
Max total length

Cooling
Cooling

Min~Max
Min~Max

HP
kw
kw
kw
kw
mm
kg
dBA
dBA
m/min
m/min
CDB
CWB

mm
m

5
5
14.0
16.0
3.52
4.00
1,680x635x765
159
72
54
95
95

8
8
22.4
25.0
5.56
5.86

10
10
28.0
31.5
7.42
7.70
1,680x930x765

57
171
171

58
185
185

8
9.5 / 15.9

13
9.5 / 19.1

16
9.5 / 22.2

187

12
12
33.5
37.5
9.62
9.44

14
14
40.0
45.0
12.4
11.30

240

316

78
196
196
-5.0~43.0
-20.0~15.0
R-410A
3N~/400V/50Hz
19

233
233

23
12.7 / 28.6

18
18
49.0
56.5
16.2
15.30
324
83
63
239
239

80
60

1000

97

16
16
45.0
50.0
14.2
12.90
1,680x1,240x765

26

29
15.9 / 28.6

RXYQ20-36P7W1B(A)
VRVIII Inverter heat pump
Small footprint combination

l
l
l

l
l
l
l
l
l
l

l
l
l

RXYQ20-24P

Increased outdoor unit capacity up to 54 HP


Wide range of indoor units: 13 different models in a
total of 75 variations
Flexible combination of outdoor units: small
footprint combination, high COP combination or any
other combination of your choice
Compact size of outdoor units
Increased COP
Increased external static pressure: up to 78.4Pa
2 steps in night quiet mode: eg. 10HP: 58 dBA, 1st
step: 54dBA, 2nd step: 45dBA
In line with RoHS
Easy combination with HRV
Connectable to current Daikin control systems: DSnet, Intelligent Touch Controller, Intelligent Manager,
BACnet Gateway, DMS-IF
Easy installation thanks to automatic refrigerant
charging operation, automatic test operation
Quiet operation
Leak detection function

RXYQ26-30P

RXYQ32-36P

Heat pump
RXYQ-P(A)
Modules

Capacity range
Capacity
Power input (Nominal)
Dimensions
Weight
Sound Level
Air Flow Rate (nominal
at 230V)
Operation Range

20
1

RXYQ8P
RXYQ10P
RXYQ12P
RXYQ14PA
RXYQ16PA
RXYQ18PA
Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Sound Power
Sound Pressure
Cooling
Heating
Cooling
Heating

Refrigerant
Power Supply
Max n of indoor units to be connected
Piping connections
Liquid (OD)/Gas
Max total length

Cooling
Cooling

Min~Max
Min~Max

22

24

1
1

26
1

28

30

32

34

36

1
1
34
94.0
107.0
30.4
28.2

2
36
98.0
113.0
32.4
30.6

1
1
1

HP
kw
kw
kw
kw
mm
kg
dBA
dBA
m/min
m/min
CDB
CWB

mm
m

20
55.9
62.5
15.2
15.3

22
61.5
69.0
17.0
17.1

24
67.0
75.0
19.2
18.9

1
26
71.4
81.5
21.8
21.2

171 + 196
171 + 196

185 + 196
185 + 196

196 + 196
196 + 196

171 + 239
171 + 239

32

35

39
15.9 / 34.9

42

15.9 / 28.6

1
28
77.0
88.0
23.6
23.0
185 + 239
185 + 239
-5.0~43.0
-20.0~15.0
R-410A
3N~/400V/50Hz
45
1000

98

1
30
82.5
94.0
25.8
24.7

1
32
89.0
102.0
28.6
26.6

196 + 239
196 + 239

49
19.1 / 34.9

233 + 239
233 + 239

52

239 + 239
239 + 239

55

58
19.1 / 41.3

RXYQ38-54P7W1B(A)
VRVIII Inverter heat pump
Small footprint combination

RXYQ38-42P
l
l
l

l
l
l
l
l
l
l

l
l
l

RXYQ44-48P

RXYQ50-54P

Increased outdoor unit capacity up to 54 HP


Wide range of indoor units: 13 different models in a
total of 75 variations
Flexible combination of outdoor units: small
footprint combination, high COP combination or any
other combination of your choice
Compact size of outdoor units
Increased COP
Increased external static pressure: up to 78.4Pa
2 steps in night quiet mode: eg. 10HP: 58 dBA, 1st
step: 54dBA, 2nd step: 45dBA
In line with RoHS
Easy combination with HRV
Connectable to current Daikin control systems: DSnet, Intelligent Touch Controller, Intelligent Manager,
BACnet Gateway, DMS-IF
Easy installation thanks to automatic refrigerant
charging operation, automatic test operation
Quiet operation
Leak detection function

Heat pump
RXYQ-P(A)
Modules

Capacity range
Capacity
Power input (Nominal)
Dimensions
Weight
Sound Level
Air Flow Rate (nominal
at 230V)
Operation Range

38
1

RXYQ8P
RXYQ10P
RXYQ12P
RXYQ14PA
RXYQ16PA
RXYQ18PA
Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Sound Power
Sound Pressure
Cooling
Heating
Cooling
Heating

Refrigerant
Power Supply
Max n of indoor units to be connected
Piping connections
Liquid (OD)/Gas
Max total length

Cooling
Cooling

Min~Max
Min~Max

40

42

1
1

44
1

46

48

50

52

54

1
2
52
143.0
163.0
46.6
43.5

3
54
147.0
170.0
48.6
45.9

1
1
1

HP
kw
kw
kw
kw
mm
kg
dBA
dBA
m/min
m/min
CDB
CWB

mm
m

1
38
105.0
119.0
31.4
30.6

1
40
111.0
126.0
33.2
32.4

1
42
116.0
132.0
35.4
34.2

2
2
46
48
126.0
132.0
145.0
151.0
39.8
42.0
38.3
40.0
171 + 196 + 239 185 + 196 + 239 196 + 196 + 239 171 + 239 + 239 185 + 239 + 239 196 + 239 + 239
171 + 196 + 239 185 + 196 + 239 196 + 196 + 239 171 + 239 + 239 185 + 239 + 239 196 + 239 + 239
-5.0~43.0
-20.0~15.0
R-410A
3N~/400V/50Hz
61
64
19.1 / 41.3
1000

99

2
44
120.0
138.0
38.0
36.5

2
50
138.0
158.0
44.8
41.9

233 + 239 + 239


233 + 239 + 239

239 + 239 + 239


239 + 239 + 239

RXYQ16-36P7W1B

VRVIII Inverter heat pump


High COP combination

l
l
l
l
l
l
l
l

l
l
l

Wide range of indoor units: 13 different models in a


total of 75 variations
Compact size of outdoor units
Increased COP
Increased external static pressure: up to 78.4Pa
2 steps in night quiet mode: eg. 10HP: 58 dBA, 1st
step: 54dBA, 2nd step: 45dBA
In line with RoHS
Easy combination with HRV
Connectable to current Daikin control systems: DSnet, Intelligent Touch Controller, Intelligent Manager,
BACnet Gateway, DMS-IF
Easy installation thanks to automatic refrigerant
charging operation, automatic test operation
Quiet operation
Leak detection function

RXYQ20,22,24P

RXYQ26,28,30P

RXYQ32,34,36P

heat pump
RXYQ-P
Modules

Capacity range
Capacity
Power input (Nominal)
Dimensions
Air Flow Rate (nominal
at 230V)
Operation Range

16
2

18
1
1

20

22

16
44.8
50.0
11.1
11.7

18
50.4
56.5
13.0
13.6

20
56.0
63.0
14.8
15.4

1
1
22
61.5
69.0
17.0
17.1

171 + 171
171 + 171

171 + 185
171 + 185

RXYQ8P
RXYQ10P
RXYQ12P
Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Heating
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Max n of indoor units to be connected
Piping connections
Liquid (OD)/Gas
Max total length

HP
kw
kw
kw
kw
mm
m/min
m/min
CDB
CWB

185 + 185
185 + 185
-5.0~43.0
-20.0~15.0
R-410A
3N~/400V/50Hz
26
12.7 / 28.6

mm
m

29

32
15.9 / 28.6

35

1000

heat pump
RXYQ-P
Modules

Capacity range
Capacity
Power input (Nominal)
Dimensions
Air Flow Rate (nominal
at 230V)
Operation Range

24
3

RXYQ8P
RXYQ10P
RXYQ12P
Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Heating
Cooling
Min~Max
Heating
Min~Max

Refrigerant
Power Supply
Max n of indoor units to be connected
Piping connections
Liquid (OD)/Gas
Max total length

HP
kw
kw
kw
kw
mm
m/min
m/min
CDB
CWB

mm
m

26
2
1

28
1
2

24
67.2
75.0
16.7
18.9

26
72.8
81.5
18.5
19.4

28
78.4
88.0
20.4
21.3

171 + 171 + 171


171 + 171 + 171

171 + 171 + 185


171 + 171 + 185

171 + 185 + 185


171 + 185 + 185

39
15.9 / 34.9

42

45

100

30

32
1

34

36

2
32
89.4
100.0
24.8
24.7

1
2
34
95.0
107.0
26.7
26.6

3
36
101.0
113.0
28.9
28.3

171 + 196 + 196


171 + 196 + 196

185 + 196 + 196


185 + 196 + 196

196 + 196 + 196


196 + 196 + 196

52

55

58
19.1 / 41.3

3
30
84.0
94.5
22.3
23.1
185 + 185 + 185
185 + 185 + 185
-5.0~43.0
-20.0~15.0
R-410A
3N~/400V/50Hz
48
19.1 / 34.9
1000

REYQ18-48P7Y1B
VRVIII Heat recovery

REYQ18-24P
l

Its operation range for example 8hp to 48hp in


2hp increment steps (21 system combinations), is
wider than any of its contemporaries.
Its ability to run no less than 64 indoor units
in heat recovery format cannot at present be
matched by other comparable systems.
The ability to control each conditioned zone
keeps VRVIII system running costs to an absolute
minimum.
Only those areas calling for air conditioning need
to be cooled or heated and the system can be
shut down completely in unoccupied rooms.
Modular design enables Daikin VRVIII outdoor
units to be joined together in rows with an
outstanding degree of uniformity.

l
l
l
l
l

REYQ42-44P

The design of the outdoor units is sufficiently


compact to allow them to be taken up to the top
of a building in a commercial elevator, overcoming
site transportation problems.
Increased EER/COP
Extra low noise during night time operation (step
1: 50 dBA; step 2: 45 dBA).
Continuous heating (resulting in a higher
integrated heating capacity).
Quick cool/heat change over.
Typical VRVIII specs (longer piping length,
higher distance between outdoor & indoor unit,
autocharging).

Heat Recovery
Outdoor unit
Capacity range
Modules

Capacity

HP
REMQ8P
REMQ10P
REMQ12P
REMQ14P
REMQ16P
Cooling
Heating
(Height x Width x Depth)

Dimensions
Weight
Air Flow Rate (nominal at 230V) Cooling
Refrigerant
Power Supply
Piping connections
Liquid (OD)
Gas
Discharge Gas
Oil Equalising

8
8

10
10

12
12

14
14

16
16

18
18
1
1

20
20
1
1

REYQ8-16P are supplied as single complete units

kw
kw
mm
kg
m/min

22.4
25.0

28.0
31.5

33.5
37.5
1,680x1,300x765

40.0
45.0

210

235

331

45.0
50.0

339

190

3~,50Hz, 380-415V
mm
mm
mm
mm

95.2
19.1
15.9

12.7
22.2
19.1
none

22
22

24
24

1
1

26
26

28
28

50.4
56.5

55.9
61.5
67.0
62.5
69.0
75.0
1,680x930 + 930x765
204 + 254
254 + 254
180+185
180+200
185+200
200+200
240
R-410A
3~/380-415V/50Hz
15.9
28.6
28.6
22.2
19.1

1
1
1
73.0
78.5
81.5
87.5
1,680x930 + 1,240x765
254 + 334
185+230
200+230

19.1
34.9

Heat Recovery
Outdoor unit
Capacity range
Modules

Capacity

HP
REMQ8P
REMQ10P
REMQ12P
REMQ14P
REMQ16P
Cooling
Heating
(Height x Width x Depth)

Dimensions
Weight
Air Flow Rate (nominal at 230V) Cooling
Refrigerant
Power Supply
Piping connections
Liquid (OD)
Gas
Discharge Gas
Oil Equalising

30
30

32
32

34
34
1
1

36
36
1
1

kw
kw
mm
kg
m/min

mm
mm
mm
mm

1
1
2
85.0
90.0
95.0
100.0
1,680x1,240 + 1,240x765
334 + 334
230 + 230

34.9

38
38

40
40

1
1

42
42

44
44

46
46

48
48

1
1

1
1
1
1
2
2
2
3
101.0
107.0
112.0
118.0
124.0
130.0
135.0
113.0
119.0
125.0
132.0
138.0
145.0
150.0
1,680x930 + 930 + 1,240x765
1,680x930 + 1,240 + 1,240x765 1,680x1,240 + 1,240 + 1,240x765
204 + 254 + 334
254 + 254 + 334
254 + 334 + 334
334 + 334 + 334
180+185+230 180+200+230 185+200+230 200+200+230 185+230+230 200+230+230
230 +230 + 230
R-410A
3~/380-415V/50Hz
19.1
41.3
28.6
34.9
19.1
1
95.4
107.0

101

RWEYQ-MY1
Water-cooled VRV

RWEYQ10M
l
l
l
l
l
l
l

Wide condensing unit range: 10, 20 & 30HP via 1


single refrigerant circuit
High COP values: 5.21 nominal value
Up to 32 indoor units connectable to a 30HP
condensing unit
Wide range of indoor units: 13 different models in a
total of 75 variations
Compact design
Operation range (inlet water temperature): 10-45C
Connectable to current Daikin control systems: DSnet, Intelligent Touch Controller, Intelligent Manager,
BACnet Gateway, DMS-IF
Flexible piping length

heat recovery
Outdoor Unit
Capacity range
Capacity
Power input (Nominal)

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)

Dimensions
Weight
Sound Level
Sound Pressure Cooling
Refrigerant
Power Supply
Max n of indoor units to be connected
Piping connections
Liquid (OD)/Discharge Gas

HP
kw
kw
kw
kw
mm
kg
dBA

RWEYQ10MY1
10
26.70
31.50
6.03
6.05
1000x780x550
150
51.0

mm

16
9.5 / 22.2 / 19.1

HP
kw
kw
kw
kw
mm
kg
dBA

RWEYQ10MY1
10
26.70
31.50
6.03
6.05
1000x780x550
150
51.0

mm

16
9.5/22.2

RWEYQ20MY1
20
53.40
63.00
12.10
12.10

RWEYQ30MY1
30
80.10
94.50
18.10
18.20
-

300
54.0
R-410A
3~/380-415V/50Hz
20
15.9 / 28.6 / 22.2

450
56.0

32
19.1 / 34.9 / 28.6

RWEYQ20MY1
20
53.40
63.00
12.10
12.10

RWEYQ30MY1
30
80.10
94.50
18.10
18.20

HEAT PUMP
Outdoor Unit
Capacity range
Capacity
Power input (Nominal)

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)

Dimensions
Weight
Sound Level
Sound Pressure Cooling
Refrigerant
Power Supply
Max n of indoor units to be connected
Piping connections
Liquid (OD)/Discharge Gas

300
54.0
R-410A
3~/380-415V/50Hz
20
15.9/28.6

102

450
56.0

32
19.1/34.9

FXFQ-P7VEB

Round Flow Cassette

l
l
l
l
l
l
l
l
l

Modern style decoration panel in white (RAL9010)


360 air discharge ensures uniform air flow and
temperature distribution
Air discharge from the corners avoids dead zones
that may be subject to temperature differences
Comfortable horizontal air discharge ensures
draughtfree operation and prevents ceiling soiling
23 different air flow patterns possible
Fresh air intake: up to 20 %
Reduced installation height: 214mm for class 20-63
Easy visible drain check thanks to clear drain socket
Drain-up pump with 850 mm filted as standard.

except VRV
inverter
cooling only

optional

standard

optional

optional

FXFQ-P7VEB
Indoor Units
Capacity
Power input
Dimensions
Weight
Air Flow Rate
Sound power (nominal)
Sound Pressure
Refrigerant
Power Supply
Piping connections
Decoration Panel

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High/Low
High/Low

Liquid (OD)/Gas/Drain
Model
Colour
HeightxWidthxDepth
Weight

kw
kw
kw
kw
mm
kg
m/min
m/min
dBA
dBA
dBA

mm

20
2.20
2.50

25
2.80
3.20
0.053
0.045

32
3.60
4.00

40
4.50
5.00
0.063
0.055
204x840x840

20
12.5 / 9.0
12.5 / 9.0
49.0
31.0 / 28.0
31.0 / 28.0

6.35 / 12.7 / 32

13.5 / 9.0
13.5 / 9.0
50.0
32.0 / 28.0
32.0 / 28.0

50
5.60
6.30
0.083
0.067
21
15.5 / 10.0
15.0 / 9.5
51.0
33.0 / 28.0
33.0 / 28.0
R-410A
1~/220-240V/50Hz

6.40 / 12.7 / 32

103

16.5 / 11.0
17.5 / 12.0
52.0
34.0 / 29.0
36.0 / 30.0

80
100
9.00
11.20
10.00
12.50
0.120
0.173
0.108
0.176
246x840x840
24
23.5 / 14.5
26.5 / 17.0
23.5 / 14.5
28.0 / 17.5
55.0
58.0
38.0 / 32.0
41.0 / 33.0
38.0 / 32.0
42.0 / 34.0

9.5 / 15.9 / 32
BYCQ140CW1
RAL9010
50x950x950
5.5

mm
kg

63
7.10
8.00
0.095
0.114

125
14.00
16.00
0.258
0.246
288x840x840
26
33.0 / 20.0
33.0 / 20.0
61.0
44.0 / 34.0
44.0 / 34.0

FXZQ-M8V1B

600x600 4-Way Blow Ceiling


Mounted Cassette

FXZQ-M8
l

l
l
l
l

l
l
l

l
l

New and extremely compact casing (575mm in


width and depth) enables unit to fit flush into
ceilings and match standard architectural modules,
without cutting ceiling tiles
Modern style decoration panel in white (RAL9010)
Whisper quiet operation: down to 25 dBA sound
pressure level
Excellent low draught characteristics
Vertical auto-swing function moves the discharge
flaps up and down for efficient air distribution
throughout the room
Since the flaps can move to a 0 degree position,
virtually no draught can be experienced
5 different air flow patterns:
Any one of 5 air flow patterns can be freely
selected between zero and 40 degrees and will
then be maintained during the operational cycle of
the air conditioner,
Air can be discharged in any of 4 directions
Possibility to shut 1 or 2 flaps for easy installation
in corners

BRC1D52

BRC7E531/E530

except VRV
Inverter
Cooling only

optional

optional

optional

FXZQ-M8V1B
Indoor Units
Capacity
Power input
Dimensions
Weight
Air Flow Rate
Sound power (nominal)
Sound Pressure
Refrigerant
Power Supply
Piping connections
Decoration Panel

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Cooling
Cooling

High/Low
High/Low

Liquid (OD)/Gas/Drain
Model
Colour
HeightxWidthxDepth
Weight

kw
kw
kw
kw
mm
kg
m/min
dBA
dBA

FXZQ20M8V1B
2.20
2.50

FXZQ25M8V1B
2.80
3.20
0.073
0.064

9.00 / 7.00
47.0
30.0 / 25.0

mm

mm
kg

104

FXZQ32M8V1B
3.60
4.00
0.076
0.068
286x575x575
18
9.50 / 7.50
49.0
32.0 / 26.0
R-410A
1~/220-240V/50Hz
6.4 / 12.7 / 26
BYFQ60B7W1
White (Ral 9010)
55x700x700
2.7

FXZQ40M8V1B
4.50
5.00
0.089
0.080

FXZQ50M8V1B
5.60
6.30
0.115
0.107

11.00 / 8.00
53.0
36.0 / 28.0

14.00 / 10.00
58.0
41.0 / 33.0

FXCQ-M8V3B

2-Way Blow Ceiling Mounted


Cassette

FXCQ20,25,32M8
l
l
l

l
l
l

Compact dimensions, can easily be mounted in a


ceiling void of only 355mm
Easy to install: depth of all units is 600mm
Auto-swing function ensures efficient air and
temperature distribution and prevents ceiling
soiling,
Quiet operation
Leaves maximum floor and wall space for furniture,
decorations and fittings
Easy to clean flat suction grille

BRC1D52

BRC7C67/C62

except VRV
Inverter
Cooling only

optional

optional

optional

FXCQ-M8V3B
Indoor Units
Capacity
Power input
Dimensions
Weight
Air Flow Rate
Sound power (nominal)
Sound Pressure
Refrigerant
Power Supply
Piping connections
Decoration Panel

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High/Low
High/Low

Liquid (OD)/Gas/Drain
Model
Colour
HeightxWidthxDepth
Weight

kw
kw
kw
kw
mm
kg
m/min
m/min
dBA
dBA
dBA

20
2.20
2.50
0.077
0.044

7.0 / 5.0
7.0 / 5.0
45.0
33.0 / 28.0
33.0 / 28.0

25
2.80
3.20

32
3.60
4.00

0.092
0.059
305x780x600
26
9.0 / 6.5
9.0 / 6.5

50
5.60
6.30
0.130
0.097
305x995x600

31

32
12.0 / 9.0
12.0 / 9.0

50.0
35.0 / 29.0
35.0 / 29.0

mm

35.5 / 30.5
35.5 / 30.5
R-410A
1~/230V/50Hz

63
7.10
8.00
0.161
0.126
305x1180x600
35
16.5 / 13.0
16.5 / 13.0
52.0
38.0 / 33.0
38.0 / 33.0

6.35 / 12.7 / 32
BYBC32GJW1

mm
kg

40
4.50
5.00

53x1030x680
8.0

105

BYBC50GJW1
White (10Y9/0.5)
53x1245x680
8.5

80
125
9.00
14.00
10.00
16.00
0.209
0.256
0.176
0.223
305x1670x600
47
48
26.0 / 21.0
33.0 / 25.0
26.0 / 21.0
33.0 / 25.0
54.0
60.0
40.0 / 35.0
45.0 / 39.0
40.0 / 35.0
45.0 / 39.0

BYBC63GJW1

9.5 / 15.9 / 32
BYBC125GJW1

53x1430x680
9.5

53x1920x680
12.0

FXKQ-MAVE

Ceiling Mounted Corner Cassette

FXKQ63MA
l
l
l

BRC1D52

Slim design for flexible installation


Auto-swing function ensures efficient air and
temperature distribution,
Choice between 3 auto-swing positions for
maximum comfort: standard, draught prevention,
ceiling soiling prevention
Optimum air flow conditions are created by either
downward air discharge or frontal air discharge
(via optional grille) or a combination of both
Leaves maximum floor and wall space for furniture,
decorations and fittings

BRC4C63/C61

except VRV
Inverter
Cooling only

optional

optional

optional

FXKQ-MAVE
Indoor Units
Capacity
Power input
Dimensions
Weight
Air Flow Rate
Sound Pressure
Refrigerant
Power Supply
Piping connections
Decoration Panel

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Cooling

High/Low
High/Low

kw
kw
kw
kw
mm
kg
m/min
dBA

FXKQ25MAVE
2.80
3.20

FXKQ32MAVE
3.60
4.00

FXKQ40MAVE
4.50
5.00
0.076
0.056

0.066
0.046
215x1110x710
31
11.00 / 9.00
38.0 / 33.0

13.00 / 10.00
40.0 / 34.0

FXKQ63MAVE
7.10
8.00
0.105
0.085
215x1310x710
34
18.00 / 15.00
42.0 / 37.0

R-410A
1~/220-240V/50Hz
Liquid (OD)/Gas/Drain
Model
Colour
HeightxWidthxDepth
Weight

mm

6.4 / 12.7 / 32
BYK45FJW1

mm
kg

70x1240x800
8.5

9.5 / 15.9 / 32
BYK71FJW1
White

106

70x1440x800
9.5

FXDQ-M8V3B

Concealed Ceiling Unit (Small)

BRC1D52
l
l
l
l
l
l
l

BRC4C64/C62

Designed for hotel bedrooms


Compact dimensions (230mm high & 652mm
deep), can easily be mounted in a ceiling void
Blends unobtrusively with any interior dcor: only
the suction and discharge grilles are visible
Extremely quiet in operation both indoors and
outdoors
The air suction direction can be altered from rear
to bottom suction
Air suction filter fitted as standard
For easy mounting, the drain pan can be located
to the left or the right of the unit.

FXDQ20,25M8

except VRV
Inverter
Cooling only

optional

optional

FXDQ-M8v3b
Indoor Units
Capacity
Power input
Dimensions
Weight
Air Flow Rate
Sound power (nominal)
Sound Pressure
Refrigerant
Power Supply
Piping connections

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High/Low
High/Low

Liquid (OD)/Gas/Drain

kw
kw
kw
kw
mm
kg
m/min
m/min
dBA
dBA
dBA

optional

FXDQ20M8V3B
2.20
2.50

FXDQ25M8V3B
2.80
3.20
0.050
0.050
230x502x652
17

6.70 / 5.20
6.70 / 5.20

7.40 / 5.80
7.40 / 5.80
50.0
37.0 / 32.0
37.0 / 32.0
R-410A
1~/230V/50Hz
6.4 / 12.7 / 27.2

mm

107

FXDQ-P/NA

Slim Concealed Ceiling Unit

BRC1D52
l
l
l
l
l
l
l

Slim design for flexible installation


Compact dimensions, can easily be mounted in a
ceiling void of only 240mm
Quiet operation: down to 29 dBA sound pressure
level
Blends unobtrusively with any interior dcor
Can be installed in both new and existing
buildings.
Leaves maximum floor and wall space for furniture,
decorations and fittings
Medium external static pressure facilitates unit use
with flexible ducts of varying lengths

BRC4C64/C62

FXDQ20-32P

except VRV
Inverter
Cooling only

optional

optional

optional

FXDQ-PVE/FXDQ-NAVE
Indoor Units
Capacity
Power input
Dimensions
Weight
Air Flow Rate
Sound Pressure
Refrigerant
Power Supply
Piping connections

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Cooling

High/Low
High/Low

Liquid (OD)/Gas/Drain

kw
kw
kw
kw
mm
kg
m/min
dBA

mm

FXDQ20PVE
2.20
2.50

FXDQ25PVE
2.80
3.20
0.086
0.067

FXDQ40NAVE
FXDQ50NAVE
4.50
5.60
5.00
6.30
0.160
0.165
0.147
0.152
200x700x620
200x900x620
23.0
27.0
28.0
8.0 / 6.4
10.50 / 8.50
12.50 / 10.00
33.0 / 29.0
34.0 / 30.0
35.0 / 31.0
R-410A
1~/220-240V/50Hz
6.4 / 12.7 / VP20 (I.D. 20/O.D. 26)

108

FXDQ32PVE
3.60
4.00
0.089
0.070

FXDQ63NAVE
7.10
8.00
0.181
0.168
200x1100x620
31.0
16.50 / 13.00
36.0 / 32.0

9.5 / 15.9 / VP20 (I.D. 20/O.D. 26)

FXSQ-M8V3B
Concealed Ceiling Unit

FXSQ20,25,32M8
l
l
l
l
l
l

Blends unobtrusively with any interior dcor


Leaves maximum floor and wall space for furniture,
decorations and fittings
Drain pump fitted as standard
Long life filter fitted as standard
The air suction direction can be altered from rear
to bottom suction
Ideal for shops, restaurants or offices requiring
maximum floor space for furniture, decorations
and fittings
High external static pressure facilitates unit use
with flexible ducts of varying lengths

BRC1D52

BRC4C64/C62

except VRV
Inverter
Cooling only

optional

optional

optional

FXSQ-M8V3B
Indoor Units
Capacity
Power input
Dimensions
Weight
Air Flow Rate
Sound power (nominal)
Sound Pressure
Refrigerant
Power Supply
Piping connections
Decoration Panel

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High/Low
High/Low

Liquid (OD)/Gas/Drain
Model
Colour
HeightxWidthxDepth
Weight

kw
kw
kw
kw
mm
kg
m/min
m/min
dBA
dBA
dBA

20
2.20
2.50

25
2.80
3.20

32
3.60
4.00
0.114
0.094

0.110
0.090
300x550x800
30
9.00 / 6.50
9.00 / 6.50
50.0
32.0 / 28.0
32.0 / 28.0

mm

9.50 / 7.00
9.50 / 7.00
51.0
33.0 / 28.0
33.0 / 28.0

6.35 / 12.7 / 32
BYBS32DJW1

mm
kg

40
50
63
4.50
5.60
7.10
5.00
6.30
8.00
0.127
0.143
0.189
0.107
0.123
0.169
300x700x800
300x1000x800
31
41
11.50 / 9.00
15.00 / 11.00 21.00 / 15.50
11.50 / 9.00
15.00 / 11.00 21.00 / 15.50
56.0
58.0
56.0
33.0 / 29.0
35.0 / 31.0
35.0 / 30.0
33.0 / 29.0
35.0 / 31.0
35.0 / 30.0
R-410A
1~/230V/50Hz
BYBS45DJW1
BYBS71DJW1
White (10Y9/0,5)
55x800x500
55x1100x500
3.5
4.5

55x650x500
3

109

80
9.00
10.00
0.234
0.214

100
11.20
12.50
0.242
0.222
300x1400x800
51
27.00 / 20.00 28.00 / 20.50
27.00 / 20.00 28.00 / 20.50
55.0
56.0
37.0 / 31.0
38.0 / 33.0
37.0 / 31.0
38.0 / 33.0

9.5 / 15.9 / 32
BYBS125DJW1
55x1500x500
6.5

125
14.00
16.00
0.321
0.301
52
38.00 / 28.00
38.00 / 28.00
65.0
40.0 / 35.0
40.0 / 35.0

FXMQ-MAVE

Concealed Ceiling Unit (Large)

FXMQ80,100,125MA

Leaves maximum floor and wall space for furniture,


decorations and fittings
l Complete range of models (5 -> 31,5 kW)
l More than 150 Pa external static pressure allows
extensive ductwork runs and flexible application:
ideal for use in large areas
l Built-in drain pump (accessory): housing the drain
pump inside the unit has reduced the required
installation space

BRC1D52

BRC4C64/C62

except VRV
inverter
cooling only

optional

optional

optional

optional

FXMQ-MAVE
Indoor Units
Capacity
Power input (Nominal)
Dimensions
Weight
Air Flow Rate
Sound Pressure
Refrigerant
Power Supply
Piping connections

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Cooling

High/Low
High/Low

Liquid (OD)/Gas/Drain

kw
kw
kw
kw
mm
kg
m/min
dBA

mm

40
4.50
5.00

50
63
5.60
7.10
6.30
8.00
0.211
0.211
390x720x690
44
14.00 / 11.50
39.0 / 35.0

6.4 / 12.7 / 32

110

80
9.00
10.00
0.284
0.284

100
125
11.20
14.00
12.50
16.00
0.411
0.619
0.411
0.619
390x1110x690
45
63
65
19.50 / 16.00
29.00 / 23.00
36.00 / 29.00
42.0 / 38.0
43.0 / 39.0
45.0 / 42.0
R-410A
1~/220-240V/50Hz
9.5 / 15.9 / 32

200
250
22.40
28.00
25.00
31.50
1.294
1.465
1.294
1.465
470x1380x1100
137
58.00 / 50.00
72.00 / 62.00
48.0 / 45.0

9.5 / 19.1 / PS1B 9.5 / 22.2 / PS1B

FXAQ-MAVE
Wall Mounted Unit

BRC1D52
l
l
l

l
l
l

BRC7E619/E618

Compact design
Fits neatly on a wall
Auto-swing function ensures efficient air
distribution via louvers that close automatically
when the unit is switched off
5 different discharge angles can be programmed
via the remote control
Both horizontal flaps and front panel can easily be
removed and washed
Discharge angle automatically returns to its
previous position on restart (initial setting 10
degrees for cooling and 70 degrees for heating)
All maintenance operations can be carried out
from the front of the unit

FXAQ40,50,63MA

optional

except VRV
Inverter
Cooling only

optional

optional

FXAQ-MAVE
Indoor Units
Capacity
Power input
Dimensions
Weight
Air Flow Rate
Sound Pressure
Refrigerant
Power Supply
Piping connections

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Cooling

High/Low
High/Low

kw
kw
kw
kw
mm
kg
m/min
dBA

FXAQ20MAVE
2.20
2.50
0.016
0.024

7.50 / 4.50
35.0 / 29.0

FXAQ25MAVE
2.80
3.20
0.022
0.027
290x795x230
11
8.00 / 5.00
36.0 / 29.0

FXAQ32MAVE
3.60
4.00
0.027
0.032

FXAQ40MAVE
4.50
5.00
0.020
0.020

9.00 / 5.50
37.0 / 29.0

12.00 / 9.00
39.0 / 34.0

FXAQ50MAVE
5.60
6.30
0.027
0.032
290x1050x230
14
15.00 / 12.00
42.0 / 36.0

FXAQ63MAVE
7.10
8.00
0.050
0.060

6.35 / 12.7 / 18

9.5 / 15.9 / 18

19.00 / 14.00
46.0 / 39.0

R-410A
1~/220-240V/50Hz
Liquid (OD)/Gas/Drain

mm

6.4 / 12.7 / 18

111

FXHQ-MAVE

Ceiling Suspended Unit

BRC1D52
l
l
l
l
l
l
l
l

BRC7E66/E63

Reduced sound pressure level


Leaves maximum floor and wall space for furniture,
decorations and fittings
Can be installed in both new and existing
buildings.
Use of W-shaped Coanda flap enhances horizontal
and vertical air circulation characteristics
Wider air discharge thanks to Coanda effect: up to
100 degrees
Easy installation and maintenance
Long life filter fitted as standard
Drain pump kit available as accessory

FXHQ32MA

except VRV
Inverter
Cooling only

optional

optional

optional

FXHQ-MAVE
Indoor Units
Capacity
Power input
Dimensions
Weight
Air Flow Rate
Sound Pressure
Refrigerant
Power Supply
Piping connections

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Cooling

High/Low
High/Low

Liquid (OD)/Gas/Drain

kw
kw
kw
kw
mm
kg
m/min
dBA

mm

FXHQ32MAVE
3.60
4.00
0.111
0.111
195x960x680
24
12.00 / 10.00
36.0 / 31.0

FXHQ63MAVE
7.10
8.00
0.115
0.115
195x1160x680
28
17.50 / 14.00
39.0 / 34.0
R-410A
1~/220-240V/50Hz

6.4 / 12.7 / 26

FXHQ100MAVE
11.20
12.50
0.135
0.135
195x1400x680
33
25.00 / 19.50
45.0 / 37.0

9.5 / 15.9 / 26

112

optional

FXUQ-MAV1

4-Way Blow Ceiling Suspended


Cassette

BRC1D52 BRC7C529/C528
l
l
l
l
l
l
l
l
l
l
l

Can be installed in both new and existing


buildings.
Group control with other VRV indoor units
possible
Cool heat selection
Prevention of cold draught at hot start, defrost and
oil return in heating
5m maximum distance between FXUQ unit and
junction box
Air can be discharged in any of 4 directions
Possibility to shut 1 or 2 flaps for easy installation
in corners
Auto-swing function ensures efficient air and
temperature distribution.
Air flow distribution for ceiling heights up to 3.5m
without loss of capacity.
Air can be discharged at 5 different angles
between 0 and 60 degrees
Air filter, drain pan and heat exchanger fin are
mildew proof and anti-bacterial treated.

FXUQ71MAV1

optional

2 steps

optional

optional

FXUQ-MAV1
Indoor Units
Capacity
Power input
Dimensions
Weight
Air Flow Rate
Sound power (nominal)
Sound Pressure

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Heating
Cooling
Cooling
Heating

High/Low
High/Low
High/Low
High/Low

Refrigerant
Power Supply
Piping connections
Liquid (OD)/Gas/Drain
Combination with junction box

kw
kw
kw
kw
mm
kg
m/min
m/min
dBA
dBA
dBA

FXUQ71MAV1
8.0
9.0
0.180
0.160
165x895x895
25
19.00 / 14.00
19.00 / 14.00
56.0
40.0 / 35.0
40.0 / 35.0

FXUQ100MAV1
11.2
12.5

FXUQ125MAV1
14.0
14.0
0.289
0.269
230x895x895
31

29.00 / 21.00
29.00 / 21.00
59.0
43.0 / 38.0
43.0 / 38.0
R-410A
1~/220-240V/50Hz
9.5 / 15.9 / I.D. 20/O.D. 26
BEVQ100M

mm
BEVQ71M

113

32.00 / 23.00
32.00 / 23.00
60.0
44.0 / 39.0
44.0 / 39.0

BEVQ125M

FXNQ-MAVE

Concealed Floor Standing Unit

FXNQ20,25MA
l
l
l
l
l

Ideal for installation beneath a window


All models are available with remote control
Long life filter fitted as standard
Requires very little installation space
The connecting port faces downward, eliminating
the need to attach auxiliary piping

BRC1D52

BRC4C64/C62

optional

except VRV
Inverter
Cooling only

optional

optional

FXNQ-MAVE
Indoor Units
Capacity
Power input
Dimensions
Weight
Air Flow Rate
Sound Pressure
Refrigerant
Power Supply
Piping connections

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Cooling

High/Low
High/Low

Liquid (OD)/Gas/Drain

kw
kw
kw
kw
mm
kg
m/min
dBA

FXNQ20MAVE
2.20
2.50

FXNQ25MAVE
2.80
3.20

0.049
0.049
610x930x220
19
7.00 / 6.00
35.0 / 32.0

mm

114

FXNQ32MAVE
3.60
4.00

FXNQ40MAVE
4.50
5.00

0.090
0.090
610x1070x220
23
8.00 / 6.00
11.00 / 8.50
38.0 / 33.0
R-410A
1~/220-240V/50Hz
6.4 / 12.7 / O.D. 21

FXNQ50MAVE
5.60
6.30

FXNQ63MAVE
7.10
8.00

0.110
0.110
610x1350x220
27
14.00 / 11.00
16.00 / 12.00
39.0 / 34.0
40.0 / 35.0

9.5 / 15.9 / O.D. 21

FXLQ-MAVE

Floor Standing Unit

FXLQ20,25MA
l
l
l
l

Ideal for installation beneath a window


All models are available with remote control
Requires very little installation space
Running the pipes from connections at the back,
enables the unit to be wall mounted which in turn
allows cleaning beneath the unit where dust tends
to accumulate
Long life filter fitted as standard

BRC1D52

BRC4C64/62

optional

except VRV
Inverter
Cooling only

optional

optional

FXLQ-MAVE
Indoor Units
Capacity
Power input
Dimensions
Weight
Air Flow Rate
Sound Pressure
Refrigerant
Power Supply
Piping connections

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Cooling

High/Low
High/Low

Liquid (OD)/Gas/Drain

kw
kw
kw
kw
mm
kg
m/min
dBA

FXLQ20MAVE
2.20
2.50

FXLQ25MAVE
2.80
3.20

0.049
0.049
600x1000x222
25
7.00 / 6.00
35.0 / 32.0

mm

115

FXLQ32MAVE
3.60
4.00

FXLQ40MAVE
4.50
5.00

0.090
0.090
600x1140x222
30
8.00 / 6.00
11.00 / 8.50
38.0 / 33.0
R-410A
1~/220-240V/50Hz
6.4 / 12.7 / O.D. 21

FXLQ50MAVE
5.60
6.30

FXLQ63MAVE
7.10
8.00

0.110
0.110
600x1420x222
36
14.00 / 11.00
16.00 / 12.00
39.0 / 34.0
40.0 / 35.0

9.5 / 15.9 / O.D. 21

FXMQ-MFV1

Outdoor Air Processing Unit

FXMQ250MF

100% fresh air intake possible


Leaves maximum floor and wall space for furniture,
decorations and fittings
l Operation range: -5C to 43C
l 225 Pa external static pressure allows extensive
ductwork runs and flexible application: ideal for
use in large areas
l Drain pump kit available as accessory
l

FXMQ-MFV1
Indoor Units
Capacity
Power input
Dimensions
Weight
Air Flow Rate
Refrigerant
Power Supply
Piping connections

Cooling
Heating
Cooling
Heating
(Height x Width x Depth)
Cooling
Heating

Medium
Medium

Liquid (OD)/Gas/Drain

kw
kw
kw
kw
mm
kg
m/min
m/min

mm

FXMQ125MFV1
14.0
8.9
0.359
0.359
470x744x1100
86
18.0
18.0

9.5 / 15.9 / PS1B

116

FXMQ200MFV1
22.4
13.9
0.548
0.548

FXMQ250MFV1
28.00
17.40
0.638
0.638
470x1380x1100
123

28.0
28.0
220-240V/50Hz
9.5 / 19.1 / PS1B

35.0
35.0

9.5 / 22.2 / PS1B

HRV
Heat Recovery Ventilation
Clean outdoor air
Total heat
exchanged foul air

The Daikin heat recovery ventilation system modulates the


temperature and humidity of incoming fresh air to match
indoor conditions. A balance is thus achieved between
indoor and outdoor ambients, enabling the cooling or
heating load placed on the air conditioning system to be
reduced signicantly.
HRV units can be controlled individually or integral with the
air conditioning system (Daikin VRV or Sky Air series).

Foul indoor air

Total heat
exchanged
clean air

9 models to choose from


Compact, energy saving ventilation
Specially developed heat exchange element
with HEP (High Efciency Paper)
Easy integration into the VRV system
Connectable to current Daikin control systems:

VAM-FA7
Ventilation
Air ow rate
Sound pressure level (max.) (1)
External static pressure (max.)
Temperature exchange efciency
Enthalpy exchange efciency
Dimensions

Weight
Duct diameter
Power supply

heating
cooling
H
W
D

m3/h
dBA
Pa
%
%
%
mm
mm
mm
kg
mm
VE

VAM150FA7 VAM250FA7 VAM350FA7 VAM500FA7 VAM650FA7 VAM800FA7 VAM1000FA7 VAM1500FA7 VAM2000FA7


150
250
350
500
650
800
1,000
1,500
2,000
27/28.5
28/29
32/34
33/34.5
34.5/35.5
36/37
36/37
39.5/41.5
40/42.5
69
64
98
98
93
137
157
137
137
74
72
75
74
74
74
75
75
75
58
58
61
58
58
60
61
61
61
64
64
65
62
63
65
66
66
66
269
269
285
285
348
348
348
710
710
760
760
812
812
988
988
988
1,498
1,498
509
509
800
800
852
852
1,140
852
1,140
24
24
33
33
48
48
61
132
158
100
150
150
200
200
250
250
350
350
1 ~, 50Hz, 220-240V

(1) Sound pressure level is measured in heat exchange mode.

117

HRV
Heat Recovery Ventilation

Heat purge (economiser): heat accumulated


indoors is discharged at night
Integration of air conditioning into HRV unit
Increased static pressure thanks to improved
fan performance
Individual control via HRV remote control
Connectable to current Daikin control systems:

VKM-GA
Ventilation & DX coil
Fresh air conditioning load
Air ow rate
Sound pressure level - 220V
Sound pressure level - 240V
Static pressure
Temperature exchange efciency
Enthalpy exchange efciency - cooling
Enthalpy exchange efciency - heating
Dimensions

Weight
Power supply

Cooling
Heating
UH - H - L
UH - H - L
UH - H - L
UH - H - L
UH - H - L
UH - H - L
UH - H - L
Height
Width
Depth

kW
kW
m3/h
dBA
dBA
Pa
%
%
%
mm
mm
mm
kg
V1

VKM50GA
4.71
5.58
500 - 500 - 440
38 - 36 - 33.5
39 -37 - 33.5
180 - 150 - 110
76 - 76 - 77.5
64 - 64 - 67
67 - 67 - 69
387
1,764
832
96

VKM80GA
7.46
8.79
750 - 750 - 640
40 - 37.5 - 34.5
41.5 - 39 - 37
170 - 120 - 80
78 - 78 - 79
66 - 66 - 68
71 - 71 - 73
387
1,764
1,214
109
1 ~, 220-240V, 50Hz

118

VKM100GA
9.12
10.69
950 - 950 - 820
40 - 38 - 35
41 - 39 - 36.5
150 - 100 - 70
74 - 74 - 76.5
62 - 62 - 66
65 - 65 - 69
387
1,764
1,214
114

1571UK_pp119-126_artwork.indd 119

24/7/07 13:21:08

In order to realise maximum efciency, commercial air conditioning


systems must be subject to precise, 24 hour control.
Daikin manufactures and markets a complete suite of advanced
computerised central control and monitoring systems designed to
simplify air conditioning management and reduce energy usage
running costs.
Daikin computerised control systems not only provide the highly
sophisticated regulation and day to day monitoring necessary for
modern, hi tech air conditioning installations they also provide
owners, landlords and tenants of commercial buildings with
valuable performance data on consumption as well as a wide range
of operating parameters.
Dedicated Daikin central control can be applied to both VRV and
mixed VRV/Sky Air and Split installations with up to 1,024 indoor
units and can also be integrated with building management
systems.

Control Systems
CENTRALISED CONTROL SYSTEMS
Centralised remote control
Unied on/off control
Schedule timer

121
121
121

NETWORK SOLUTIONS
122
123
125
126
126

120

Centralised Control Systems

DCS302C51

Centralised control of the VRV system can


be achieved via 3 user friendly compact
controls: centralised remote control, unified
on/off control and schedule timer. These
controls may be used independently or in
combination where 1 group = several (up to
16) indoor units in combination and 1 zone
= several groups in combination.
A centralised remote control is ideal for use
in tenanted commercial buildings subject to
random occupation, enabling indoor units to
be classified in groups per tenant (zoning).
The schedule timer programmes the
schedule and operation conditions for each
tenant and the control can easily be reset
according to varying requirements.

DCS301B51

DST301B51

DCS302C51

DCS301B51

DST301B51

Centralised remote control


Providing individual control of 64
groups (zones) of indoor units.

Unified ON/OFF control


Providing simultaneous and individual
control of 16 groups of indoor units.

Schedule timer
Enabling
64
programmed.

a maximum of 64 groups (128


indoor units, max. 10 outdoor units)
can be controlled
a maximum of 128 groups (128
indoor units, max. 10 outdoor units)
can be controlled via 2 centralised
remote controls in separate
locations
zone control
group control
malfunction code display
maximum wiring length of 1,000m
(total: 2,000m)
air flow direction and air flow rate
of HRV can be controlled
expanded timer function

a maximum of 16 groups (128


indoor units) can be controlled
2 remote controls in separate
locations can be used
operating status indication (normal
operation, alarm)
centralised control indication
maximum wiring length of 1,000m

a maximum of 128 indoor units can


be controlled
8 types of weekly schedule
a maximum of 48 hours back up
power supply
a maximum wiring length of
1,000m (total: 2,000m)

groups

to

be

(total: 2,000m)

121

1571UK_pp119-126_artwork.indd 121

24/7/07 13:21:20

Network Solutions

The ideal solution for control


and management up to 2,000
Sky Air and/or VRV indoor
units

DS-NET
adapter
PC for monitoring

Modem

RS458

Public
phone line

Modem

RS232C

Malfunction

Max. of
10 DS-NET
adapters

APPLICATION AREA
A small commercial area of less
than 40 indoor units.
Critical applications for centralized
monitoring.
SYSTEM LAYOUT
Allows monitoring and control of
up to up to 50 stores or sites and
2,000 indoor units with just one
modem and phone line.

Automates daily air conditioning


operation in order to free users
from the hassle of air conditioning
operation/management.
The daily schedule setting allows
automatic operation afterward.
Automates alarm (report messages)
for any malfunctions / errors.
Immediate report of any indoor
unit breakdown to the servicing
company.
Automatic report of breakdown/
malfunction information.
Minimizes the inconvenience of not
having air conditioning via rapid
messages

FUNCTIONS
Schedule setup (Daily schedule)
- Start/Stop
Air conditioning malfunction report
- Send message to monitoring
system
Manual operation
- Start/Stop, Set temperature,
Operation mode, Fan speed
Status monitoring (Start/Stop, Set
temperature, Operation mode,
Room temperature, Operation time,
Error code)

122

1571UK_pp119-126_artwork.indd 122

24/7/07 13:21:21

Network Solutions

Allows detailed & easy monitoring


and operation of VRV systems
(max. 2 X 64 groups/indoor units).

third party controller


(domotics, BMS, etc.)
Public line
AIRNET

new

Onboard
modem

Fire alarm

Ethernet
Forced OFF contact input

PCMCIA
flash
memory

DIII-NET

CSV output of PPD


(option) result

Indoor units

HRV

Pi-port
Onboard
Ethernet
port

DIO unit
Links to the wattmeter when using
the PPD (option) function

Controls drain
pump lighting
etc.

Malfunction

Monitoring of
room enter/exit
sign
DI unit

new

Remote monitoring/control via


internet, e-mail
PPD data is available on the internet
RS-232C

DIII-NET Allows monitoring/control


of up to 64 units (groups) of A/Cs
and equipment

DIII-NET PLUS
adapter
Indoor units

HRV

123

1571UK_pp119-126_artwork.indd 123

24/7/07 13:21:55

LANGUAGES
English
German
Spanish

French
Italian

SYSTEM LAYOUT
Up to 2 x 64 indoor units can be
controlled
Onboard Ethernet port (web
browser + e-mail)
Digital i/o contacts (option)
Touch panel (full colour LCD via
icon display)

ne

MANAGEMENT
Web application & internet
compatibility
- Monitoring & control according to user
- Remote monitoring & control of
more than one building
- Remote monitoring & control of
more than one building via internet
Power Proportional Distribution:
PPD (option)
PPD data is available on the internet
Easy management of electricity
consumption
Enhanced history function

CONTROL

MONITORING

Individual control
(set point, start/stop, fan speed)
(max. 2 x 64 groups/indoor units)
Enhanced scheduling function
(8 schedules, 17 patterns)
Flexible grouping in zones
Yearly schedule
Fire emergency stop control
Interlocking control
Increased HRV monitoring and
control function
Automatic cooling / heating
change-over
Heating optimization
Temperature limit
Password security: 3 levels (general,
administration & service)
Quick selection and full control
Simple navigation

Visualisation via Graphical User


Interface (GUI)
Icon colour display change function
Indoor units operation mode
Error messages via e-mail & mobile
phone (option)
Indication filter replacement
Multi PC

COST PERFORMANCE
Labour saving
Easy installation
Compact design: limited installation
space
Overall energy saving

OPEN INTERFACE
Communication to any third party
controller (domotics, BMS, etc.) is
possible via open interface

CONNECTABLE TO:

VRV
HRV
Sky Air (via interface adapter)
Split (via interface adapter)

124

1571UK_pp119-126_artwork.indd 124

24/7/07 13:22:04

Network Solutions

The ideal solution for control


and management of maximum
1,024 VRV indoor units.

4 units max.

Intelligent Processing
unit (IPU)

Operation Status Monitoring


Schedule Management
Tenant Management
...etc
Fire alarm

Security

Centralised
control systems

HRV

Indoor units

MANAGEMENT

MONITORING

Web access (option)


Power Proportional Distribution
(option)
Operational history management
(start/stop, malfunction, operation
hours)
Generation of reports (graphics &
tables) (daily, weekly, monthly)
Peak load shedding
Advanced tenant management
Sliding temperature
Eco mode (option)

Visualisation via a Graphical User


Interface (GUI) featuring free
layout
Operation mode of indoor units
Fault indication
Indication filter replacement
Setpoint indication
Operation time monitoring
Multi PC
On-line help

ne

English
French
German
Italian
Spanish

LANGUAGES

SYSTEM LAYOUT
Up to 1,024 indoor units can be
controlled (by 4 iPUs)
Ethernet TCPIP / 10 base / T
communication
Integrated digital contacts on the
Intelligent Processing Unit (iPU)
19 general input ports
2 digital outputs
Stand alone operation of the iPU
for minimum 48 hours
Compatible with UPS shutdown
software

COST PERFORMANCE

CONTROL
Individual control (setpoint, start/
stop, fan speed) (max. 1,024 indoor
units)
Group control (100 groups)
Schedule control (128 programs)
Fire emergency stop control (32
programs)
Interlocking control
Setpoint limitation
Automatic cooling/heating change-over
Power failure/release control
Temperature limit (automatic start)
Timer extension

Labour saving
Easy installation
Compact design: limited installation
space
Overall energy saving

CONNECTABLE TO:

VRV
HRV
Sky Air (via interface adapter)
Split (via interface adapter)

125

1571UK_pp119-126_artwork.indd 125

24/7/07 13:22:08

Lon (FTT-10A)

LonWorks Networks
Compatible Gateway
Interface for Lon connection to
LonWorks networks
Communication via Lon protocol
(twisted pair wire)
64 units connectable per DMS-IF
Unlimited sitesize
Quick and easy installation

Lon BMS

Fire alarm

Security
Elevator
Pump
Lighting
...etc
Power supply facility
Centralised
control systems

HRV

Indoor units

BACnet
over ethernet

ne

Integrated control system


connecting VRV system
with BMS system
PPDdata is available on BMS system
Interface for BMS system
Communication via BACnet
protocol (connection via Ethernet)
256 units connectable per
BACnet gateway
Unlimited sitesize
Easy and fast installation

BMS

Fire alarm

Security
Elevator
Pump
Lighting
...etc
Power supply facility
Centralised
control systems

HRV

Indoor units

126

1571UK_pp119-126_artwork.indd 126

24/7/07 13:22:28

Precise environmental control is vital in many industrial and commercial applications. Daikin offers an outstanding range
of powerful air cooled, water cooled and condenserless chiller systems that will maintain ideal conditions in even the
largest premises. Daikin water chillers are of advanced design, compact and easy to install and maintain.
They prove flexible and effective in multiple process cooling applications in for example, fish farms, wine cellars, maritime
transport, agricultural, pharmaceutical or industrial processes. When combined with air handling units or Daikin fan coil
units of course, they are ideal for air conditioning offices, hotels, restaurants and even domestic premises.
Matched and flexible equipment/refrigerant combinations enable Daikin to offer a complete range of chillers, genuinely
optimised for use with R-134a and R-407C. All chiller components - evaporator, condenser, dryer, oil etc - have been
specially selected for use with either R-407C or R-134a refrigerants. The end result is a range of hi tech, high performance
units, indicated by published EUROVENT data to be among the most energy efficient of their type on the market.
Advanced technology allied with unsurpassed product reliability and quality, make Daikin chillers the first choice
for professionals.

Applied Systems
new
new

Air-cooled / remote evaporator


EWAQ-AC
EWYQ-AC
EUWAC-FZW
EUWA-KAZW
EUWY-KAZW
EWAP-CAYN
EWYP-CAYN
EWAP-MBYN
EWAP-AJYNN
EWAP-AJYNN/A
EWTP-MBYN
EWAD-MBYN
EWAD-AJYNN
EWAD-AJYNN/Q
EWAD-AJYNN/A
EWAD-AJYNN/H
EWAD-BJYNN
EWAD-BJYNN/Q
EWAD-BJYNN/A
EWAD-BJYNN/Z
ERAP-MBYN
D.I.C.N. (Daikin Integrated Chiller Network)
EHMC
Water-cooled / remote condenser
EWWP-KAW1N
EWLP-KAW1N
EWWD-MBYN
EWLD-MBYN
EWWD-DJYNN
EWWD-DJYNN/A
EWWD-CJYNN
EWWD-BJYNN
Fan coil units
FWV/FWL/FWM/FWD/FWB

128

129
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
153
154
155
156
157
158
159
160

EWAQ-AC /
EWYQ-AC

Air cooled

STRENGTHS
l Optimised for use with R-410A.
l Inverter controlled swing compressor
- Precise temperature control
- No buffer tank required.
l PE treated condenser coil.
l Heating operation from -15C to 43C.
l Integrated hydronics
- valves, filter, flow switch
- 3 speed pump
- 6l expansion vessel.
l Adaptive control possibility.

CONTROL
Leaving water control.
l setpoint in heating & cooling.
l

EWAQ005AC

AVAILABLE INPUTS
Voltage free contact:
- ON/OFF.
- Cooling/Heating changeover.
l Schedule timer:
- ON/OFF.
- Dual setpoint.
- Silent operation.
l

OPTIONS (factory mounted)


Evaporator heater tape.

Cooling only
Outdoor Units
Capacity
Power input
EER
Dimensions
Expansion vessel
Unit
Sound Power
Sound Pressure
Refrigerant type
Power Supply
Piping connections

INVERTER

Cooling
Cooling

kW
kW

(Height x Width x Depth)


Volume

mm
l
bar
kg
dBA
dBA

EWAQ005AC
5.2
1.89
2.75

EWAQ006AC
6.0
2.35
2.55
805x1190x360
6
1
100
62
48
R-410A
1~/230V/50Hz
1" mbsp
hose nipple 1/2" fbsp

62
48

Water heat exchanger inlet / outlet


Water heat exchanger drain

Heat Pump
Outdoor Units
Capacity
Power input
EER
COP
Dimensions
Expansion vessel
Unit
Sound Power
Sound Pressure
Refrigerant type
Power Supply
Piping connections

63
50

INVERTER

Cooling
Heating
Cooling
Heating

kW
kW
kW
kW

(Height x Width x Depth)


Volume

mm
l
bar
kg
dBA
dBA
dBA

Cooling
Heating

EWAQ007AC
7.1
2.95
2.41

EWYQ005AC
5.2
5.65
1.89
1.97
2.75
2.87

EWYQ006AC
6.0
6.35
2.35
2.24
2.55
2.83
805x1190x360
6
1
100
62
48
48
R-410A
1~/230V/50Hz
1" mbsp
hose nipple 1/2" fbsp

62
48
48

Water heat exchanger inlet / outlet


Water heat exchanger drain

129

EWYQ007AC
7.1
7.75
2.95
2.83
2.41
2.74

63
50
49

EUWAC-FZW

Air cooled

EUWAC8FZW1

STRENGTHS
l Daikin scroll compressor.
l Standard reverse phase protection.
l High static pressure (up to 150Pa).
l Operation down to -10C ambient temperature.
l Pressure gauges.

CONTROL
l Microprocessor control.
l Water inlet temperature control.
AVAILABLE INPUTS / OUTPUTS
Input
ON / OFF (per circuit).
l Pump / flow switch.
l

OPTIONS (factory mounted)


Chilled water temperature down to
- 5C (ZH) or -10C (ZL).

Output
Compressor operation.
l Summary alarm.
l Pump relay contact.
l

ACCESSORIES (kit)
Filter.
l BMS gateway
(MODBUS / J-BUS / BACNET protocol).
l Remote user interface.
l Hydraulic module.
l

Cooling only
Outdoor Units
Capacity
Power input
EER
Dimensions
Unit
Sound Power
Refrigerant type
Power Supply
Piping connections

NON-INVERTER

Cooling
Cooling

kW
kW

(Height x Width x Depth)

mm
kg
dBA

EUWAC5FZW1
11.60
5.25
2.21
1345x856x630
164
63

EUWAC8FZW1
18.40
7.78
2.37
1290x1180x630
224
66
R-407C
3N~/400V/50Hz
fbsp 1"
field installation

Evaporator water inlet/outlet


Evaporator water drain

130

EUWAC10FZW1
23.80
9.85
2.42
1395x1330x630
261
69

EUWA-KAZW

Air cooled

EUWAN16KAZW

STRENGTHS
l Integrated hydraulic module
(models B and P).
l Built-in buffer tank (model B).
l Daikin scroll compressor.
l Standard main isolator switch.
l Standard water flow switch.
l Standard filter
(delivered as a kit with the unit).
l Operation down to -15C ambient
temperature.
l Standard reverse phase protection.
l Standard condenser protection grille.
l Freeze-up protection and prevention.
l PE treated condenser coil.

ACCESSORIES (kit)
Refrigerant pressure gauges.
l BMS gateway
(MODBUS/J-BUS/BACNET protocol).
l Remote user interface.
l 200l buffer tank.
l Soft starter (single circuit).
l

CONTROL
Microprocessor control.
l Water inlet temperature control.
l

AVAILABLE INPUTS / OUTPUTS


Input
Remote ON/OFF.
l Pump contact.
l

OPTIONS (factory mounted)


Chilled water temperature down to
- 5C (OPZH) or -10C (OPZL).
l High ESP fans (50Pa) (OPHF).
l Pump size up (OPHP).

Output
Compressor operation.
l Pump relay contact.
l Summary alarm.

Cooling only
Outdoor Units
Capacity
Power input
EER
Dimensions
Buffer tank volume
Unit
Sound Power
Refrigerant type
Power Supply
Piping connections

NON-INVERTER
B5

Cooling
Cooling

kW
kW

(Height x Width x Depth)


Volume

mm
l
kg
dBA

Evaporator water inlet/outlet


Evaporator water drain

N5
P5
B8
N8
11.30
17.90
4.64 4.52 4.64 7.39 7.38
2.44 2.5 2.44 2.42 2.43
1230x1290x734
55
55
180 150 168 241 215
67
76

P8

B10

7.39
2.42

8.74
2.57

229

55
271

1-1/4"
15 mm

131

N10 P10 B12 N12 P12 B16 N16 P16 B20 N20 P20 B24 N24 P24
22.50
26.50
37.00
46.60
55.30
8.79 8.74
11.50
15.00 15.20 15.00 17.90 18.10 17.90
24.00
2.56 2.57
2.3
2.47 2.43 2.47 2.6 2.57 2.6
2.3
1450x1290x734
1321x2580x734
1541x2580x734
55
55
55
55
245 259 274 248 262 460 430 448 520 490 508 526 496 514
78
79
81
R-407C
3N~/400V/50Hz
1-/4"
1-1/4"
2"
15 mm
15 mm
15 mm

EUWY-KAZW

Air cooled

EUWYN16KAZW

STRENGTHS
l Integrated hydraulic module
(models B and P).
l Built-in buffer tank (model B).
l Daikin scroll compressor.
l Standard main isolator switch.
l Standard water flow switch.
l Standard filter (delivered as a kit
with the unit).
l Operation down to -15C ambient
temperature.
l Standard reverse phase protection.
l Standard condenser protection grille.
l Freeze-up protection and prevention.
l PE treated condenser coil.

ACCESSORIES (kit)
Refrigerant pressure gauges.
l BMS gateway
(MODBUS/J-BUS/BACNET protocol).
l Remote user interface.
l 200l buffer tank.
l Soft starter (single circuit).
l

CONTROL
microprocessor control.
l Water inlet temperature control.
l

AVAILABLE INPUTS / OUTPUTS


Input
Remote ON/OFF.
l Pump contact.
l Remote cool/heat selection.
l

OPTIONS (factory mounted)


Chilled water temperature down to
- 5C (OPZH) or -10C (OPZL).
l High ESP fans (50Pa) (OPHF).
l Pump size up (OPHP).
l

Output
Compressor operation.
l Summary alarm.
l Pump relay contact.
l

Heat Pump
Outdoor Units
Capacity
Power input
EER
COP
Dimensions
Nominal Water Flow
Buffer tank volume
Unit
Sound Power
Refrigerant type
Power Supply
Piping connections

NON-INVERTER
B5

Cooling
Heating
Cooling
Heating

kW
kW
kW
kW

(Height x Width x Depth)


Cooling
Heating
Volume

mm
kPa
kPa
l
kg
dBA

Evaporator water inlet/outlet


Evaporator water drain

N5
P5
B8 N8
9.10
17.10
11.90
18.50
3.78
7.46 7.45
4.59
7.10
2.41
2.29 2.3
2.59
2.61
1230x1290x734
10
25
17
29
55
55
193 163 181 253 227
67
76

P8

B10 N10 P10 B12 N12 P12 B16 N16 P16 B20
21.00
25.00
34.20
24.00
27.00
37.00
7.46
8.57
11.40
14.90
9.10
10.80
14.20
2.29
2.45
2.19
2.3
2.64
2.5
2.61
1450x1290x734
1321x2580x734
24
33
12
31
38
14
55
55
55
55
241 284 258 272 284 258 272 485 455 473 546
78
79
R-407C
3N~/400V/50Hz
1-1/4"
15mm

132

N20 P20 B24 N24 P24


40.00
50.00
46.00
54.00
16.30
22.80
17.40
21.60
2.45
2.19
2.64
2.5
1541x2580x734
19
16
22
55
516 534 546 516 534
81

2"
15mm

EWAP-CAYN

Air cooled

EWAP060CAYN

STRENGTHS
l Integrated hydraulic module.
l Standard main isolator switch.
l Standard water flow switch.
l Filter.
l Operation down to -10C ambient temperature
(-18C with option inverter fans (OPIF)).
l Standard reverse phase protection.
l Freeze-up protection and prevention.
l Black epoxy treated condenser coil.

CONTROL
l Microprocessor control.
l Water outlet temperature control.
l Weekly operating schedule.
l Water inlet temperature control.
AVAILABLE INPUTS / OUTPUTS
Input
ON / OFF (per circuit).
l Dual setpoint.
l Floating setpoint
(analog input 0 - 10V).
l

OPTIONS (factory mounted)


Hydraulic module with single pump.
l Hydraulic module with double pump.
l Buffer tank up to 570l.
l Low noise (-3 to -7dB(A)).
l Double pump.
l Single / Double pump contactors.
l High ESP fans (60 to 80Pa).
l Ultra-low operation.
outdoor temperature (-18C).
l LON communication card.
l Pressure gauges.
l Condenser protection grilles.
l Chilled water temperature down
to -4C (OPZH) or -12C (OPZL).
l

Output

l Compressor

operation.
alarm (per circuit).
l Pump relay contact.
l Summary

POSSIBLE CONFIGURATIONS
l Standard unit (N)
l Unit with hydraulic module (P)
- Pump (single or double)
- Expansion vessel
- Adjusting valve
- Drain
- Water pressure gauge
- Pressure relief valve
- Filter
l Unit with hydraulic module
& buffer tank (B).

Cooling only
Outdoor Units
Capacity
Power input
EER
Dimensions
Nominal Water Flow
Buffer tank volume
Expansion vessel
Unit
Sound Power
Sound Pressure
Refrigerant type
Power Supply
Piping connections

NON-INVERTER

Cooling
Cooling

kW
kW

(Height x Width x Depth)


Cooling
Volume
Volume

mm
kPa
l
l
bar
kg
dBA
dBA

Evaporator water inlet/outlet


Evaporator water drain

060
080
62.5
76.2
24.4
28.8
2.56
2.65
1897x2800x1100 1897x3200x1100
33
38
370

834
85
53

954
86
54

100
101.9
36.4
2.8
46

120
125
121.8
129.7
43.6
50.5
2.79
2.57
2092x3200x1100
43
44
410

25
1
1124
86
55

iso r7 2"
hose tube 15x21

1260
90
59

1284
91
59

iso r7 2" 1/2


hose tube 15x21

133

130
160
128.9
157.1
49.1
57.9
2.63
2.71
1897x3400x2300
30
36

180
182.8
68.4
2.67
30

210
240
214.2
241.3
77.9
88.3
2.75
2.73
2100x3400x2300
35
38

260
261.8
102.4
2.56

2181
95
63

2377
95
63

41

570
35
1.5
1588
88
56
R-407C
3~/400V/50Hz

1778
89
57

2030
89
57

2344
95
63

iso r7 3"
hose tube 15x21

EWYP-CAYN

Air cooled

EWYP060CAYN

AVAILABLE INPUTS / OUTPUTS

STRENGTHS
l Integrated hydraulic module.
l Built-in buffer tank.
l Standard main isolator switch.
l Standard water flow switch.
l Filter.
l Operation down to -10C ambient
temperature.
l Standard reverse phase protection.
l Freeze-up protection and prevention.
l Black epoxy treated condenser coil.

Input
l ON / OFF (per circuit).
l Dual setpoint.
l Heat/Cool Switch.
l Floating setpoint.
(analog input 0 - 10V).
Output
Compressor operation.
l Summary alarm (per circuit).
l Pump relay contact.
l

OPTIONS (factory mounted)


Hydraulic module with single pump.
l Hydraulic module with double pump.
l Buffer tank up to 570l.
l Low noise (-3 to -7dB(A)).
l Double pump.
l Single / Double pump contactors.
l High ESP fans (60 to 80Pa).
l LON communication card.
l Pressure gauges.
l Condenser protection grilles.
l Chilled water temperature down
to -4C (OPZH) or -12C (OPZL).

POSSIBLE CONFIGURATIONS
Standard unit (N)
l Unit with hydraulic module (P)
- Pump (single or double)
- Expansion vessel
- Adjusting valve
- Drain
- Water pressure gauge
- Pressure relief valve
- Filter
l Unit with hydraulic module
& buffer tank (B)

CONTROL
Microprocessor control.
l Water output temperature control.
l Weekly operating schedule.
l

Heat Pump
Outdoor Units
Capacity
Power input
EER
COP
Dimensions
Nominal Water Flow
Buffer tank volume
Expansion vessel
Unit
Sound Power
Sound Pressure
Refrigerant type
Power Supply
Piping connections

NON-INVERTER

Cooling
Heating
Cooling
Heating

kW
kW
kW
kW

(Height x Width x Depth)


Cooling
Heating
Volume
Volume

mm
kPa
kPa
l
l
bar
kg
dBA
dBA

Evaporator water inlet/outlet


Evaporator water drain

060
60.8
59.6
25.4
24.9
2.39

075
73.6
72.7
30.1
30.4
2.45

2.39
1897x2800x1100 1897x3200x1100
31
35
31
35
370

834
85
53

954
86
54

095
93.6
99.2
37.6
43
2.49
2.31
39
39

110
120
116
122
112
120
42.8
49.7
45.7
48.6
2.71
2.45
2.45
2.47
2092x3200x1100
40
39
40
39
410

25
1
1124
86
55

iso r7 2"
hose tube 15x21

1260
90
59

1284
91
59

iso r7 2" 1/2


hose tube 15x21

134

130
126
119
51.1
49.5
2.47

150
153
145
60.7
60.4
2.52

2.4
1897x3400x2300
28
35
28
35

170
167
172
69.8
69.6
2.39
2.47
25
25

200
220
195
229
198
228
78.2
91.6
84.5
86.5
2.49
2.5
2.34
2.64
2100x3400x2300
29
32
29
32

250
247
247
102
101
2.42
2.45

2181
95
63

2377
95
63

36
36

570
35
1.5
1588
88
56
R-407C
3~/400V/50Hz

1778
89
57

2030
89
57

2344
95
63

iso r7 3"
hose tube 15x21

EWAP-MBYN

Air cooled

EWAP200MBYN

ACCESSORIES (kit)
Leaving water control sensor for DICN.
l BMS card.
l BMS gateway
(MODBUS/J-BUS/BACNET protocol).
l Remote user interface (EKPUPC).

STRENGTHS
l DAIKIN stepless single screw compressor.
l Operation down to -15C ambient
temperature.
l Standard reverse phase protection.
l Freeze-up protection and prevention.
l PE treated condenser coil.
l VICTAULIC joints and filter as standard.
l DICN operation as standard within same series.
l Chilled water temperature down to
- 5C(ZH) or -10C(ZL) (user setting).
l Standard discharge shut-off valve.
l Standard flow switch.
l Modular design.

Low noise
operation

CONTROL
Microprocessor control.
l Water inlet or outlet temperature control.
l Weekly operating schedule.
l

AVAILABLE INPUTS / OUTPUTS


Input
ON / OFF (per circuit).
l Dual setpoint through analog signal.
l Floating setpoint.
l Pump / flow switch.
l

OPTIONS (factory mounted)


l Dual pressure relief valve on the condenser.
l Main isolator switch.
l Condenser protection grilles.
l Low noise (-5 to -7dB(A)).
l Compressor suction stop valve.
l Ampere & Voltmeter
(read-out on switchbox).
l Hi-ESP fans.
l Inverter fans.
l Heat Recovery.

Output
Compressor operation.
l Summary alarm (per circuit).
l Pump relay contact.
l

Cooling only
Outdoor Units
Capacity
Power input
EER
Dimensions
Nominal Water Flow
Unit
Sound Power
Refrigerant type
Power Supply
Piping connections

Cooling
Cooling

kW
kW

(Height x Width x Depth)


Cooling

mm
kPa
kg
dBA

Evaporator water inlet/outlet


Evaporator water drain

110
111.00
41.90
2.65

140
144.00
51.80
2.78
2250x2346x2238
48.0
1571
96

160
164.00
64.30

280
340
285.00
349.00
108.00
140.00
2.55
2.64
2.49
2250x4280x2238
50.0
41.0
31.0
42.0
52.0
1417
1660
2203
2583
2633
91
97
99
100
R-407C
3~/400V/50Hz
flexible coupling + counterpipe for welding 3"od
flexible coupling + counterpipe for welding 3"
field installation
1/4"g

135

200
199.00
78.10

400
395.00
156.00
2.53
35.0
4865

460
468.00
189.00
2.48
2250x5901x2238
39.0
4988
101

540
541.00
222.00
2.44
44.0
5111

flexible coupling + counterpipe for welding 5"


1/4"g

EWAP-AJYNN

Cooling Only

EWAP-AJYNN

STRENGTHS
l All models are PED pressure vessel approved
l Stepless single-screw compressor
l Optimised for use with R-407C
l Cooling range: 7901650kW
l EER range up to 2,35
l 2 -3 truly independent refrigerant circuits
l Standard electronic expansion valve
l DX shell and tube evaporator one pass
l Refrigerant side for easy oil circulation and return
l Several operating sound levels down to 101dB
STANDARD AVAILABLE
Glycol application
l Evaporator heater
l Main switch
l Electronic expansion valve
l

OPTIONS (factory mounted)


l Single pump (800-900-950-10-11-12-13-14)
l Twin pump (800-900-950-10-11-12-13-14)
l Total heat recovery
l Partial heat recovery
l High ESP fans
l Reduced noise / Low noise
l Fan silent
l Low ambient
l Power factor 0.9
l Suction stop valve
l A/V meter
l Gauges
l Coil guards
l Soft starter
l Blank cu/al coils
ACCESSORIES
Communication cards (EKAC200J EKACLON)
l Bacnet gateway (EKBMSBNJ)
l Remote user interface (EKRUPCK)
l Buffer tanks (EKBT500N - EKBTC10N - EKBT500C
- EKBTC500C)
l Sequencing panel (EKCSCII)
l Plant visor (EKPV2J)
l Modem (EKMODEM EKGSMOD)
l Converter RS485 to RS 232 (EKCON)
l

Cooling only
Outdoor Units
Capacity
Power input
Fan

Dimensions
EER
Unit
Sound Power
Refrigerant type
Power Supply
Piping connections

Cooling
Cooling
Type
Drive
Diameter
Nominal air flow
(Height x Width x Depth)

NON-INVERTER
kW
kW

mm
m/min
mm
kg
dBA

800
790
340

3978
2520x6210x2230
2.32
5165
101

900
875
373

950
944
405

C10
1026
442

4314
4644
2520x7110x2230
2.34
2.33
5425
5555
102

C11
1092
476

4974
5304
2520x8010x2230
2.32
2.29
5795
5905
103

C12
1158
507

C13
1284
546

C14
1354
578

Helical
Direct drive
800
5970
6300
6636
2520x9170x2230 2520x10070x2230
2.28
2.35
7990
8305
8435

C15
1426
609

C16
1516
647

7440
7296
2520x10970x2230
2.34
8890
8905
104

R-407C
3~/400V/50Hz
Evaporator water inlet/outlet

victaulic, diameter 219.1mm

136

victaulic, diameter 273mm

C17
1583
682

C18
1650
717

7632
7962
2520x11870x2230
2.32
2.30
9155
9265

EWAP-AJYNN/A

Air cooled

EWAP-AJYNN

STRENGTHS
l High efficiency
l Several operating sound levels down to 102dB
l All models are PED pressure vessel approved
l Stepless single-screw compressor
l Optimised for use with R-407C
l Cooling range: 8541729kW
l EER range up to 2.69
l 2 -3 truly independent refrigerant circuits
l Standard electronic expansion valve
l DX shell and tube evaporator one pass
l Refrigerant side for easy oil circulation and return
STANDARD AVAILABLE
Glycol application
l Evaporator heater
l Main switch
l Electronic expansion valve
l

OPTIONS (factory mounted)


l Suction stop valve
l Single pump (800-900-950-10-11-12-13-14)
l Twin pump (800-900-950-10-11-12-13-14)
l Total heat recovery
l Partial heat recovery
l High ESP fans
l Reduced noise / Low noise
l Fan silent
l Low ambient
l Power factor 0.9
l A/V meter
l Guages
l Coil guards
l Soft starter
l Blank cu/al coils
ACCESSORIES
Communication cards (EKAC200J EKACLON)
l Bacnet gateway (EKBMSBNJ)
l Remote user interface (EKRUPCK)
l Buffer tanks (EKBT500N - EKBTC10N - EKBT500C
- EKBTC500C)
l Sequencing panel (EKCSCII)
l Plant visor (EKPV2J)
l Modem (EKMODEM EKGSMOD)
l Converter RS485 to RS 232 (EKCON)
l

Cooling only
Outdoor Units
Capacity
Fan

Dimensions
EER
Weight
Sound Power
Refrigerant type
Power Supply
Piping connections

Cooling
Type
Drive
Diameter
Nominal air flow
(Height x Width x Depth)

NON-INVERTER
kW

mm
m/min
mm
kg
dBA

Evaporator water inlet/outlet

850
854

5310
2520x8010x2230
2.67
5900
102

900
954

950
1028

5640
5970
2520x8910x2230
2.69
2.66
6170
6290
102
103

C10
1124

C11
1196

6300
6636
2520x9810x2230
2.65
2.61
6525
6645
103
103

victaulic, diameter 219.1mm

137

C12
1253

C13
1357

C14
1427

Helical
Direct drive
800
7962
8292
8622
2520x11870x2230 2520x12770x2230
2.63
2.65
2.63
9050
9505
9625
104
104
104
R-407C
3~/400V/50Hz

C15
1497

C16
1595

9468
9288
2520x13670x2230
2.60
2.61
10060
10075
105
105

victaulic, diameter 273mm

C17
1644

C18
1729

9618
9948
2520x14570x2230
2.51
2.55
10410
10470
105
105

EWTP-MBYN
Air cooled

EWTP280MBYN

In many applications there often exists a simultaneous


cooling and heating demand requirement alongside
one another. To benefit from this Daikin offer the
full range of R-407C EWTP110-540MBYN chillers
with heat recovery. This option further increases the
application flexibility and extends possibilities in the
hotel and leisure industry as well as the industrial and
process sectors.
By energetically recovering useful heat from the
cooling cycle that would otherwise be rejected to
outside COPs of up to 5.62 can be realized in heat
recovery mode. The heat recovery unit aims to achieve
an optimum balance between cooling and heat
recovery to maximize the unit efficiency and offer
savings in hot water production.

For full heat recovery both sensible and latent heat


exchange will occur in the recovery exchanger.
Inverter fans will be used to control the recovery
outlet water temperature, by throttling back the
airflow and maintaining the required condensing
temperature.
As a desuperheater the sensible heat from the hot
discharge gas will be recovered, while the latent heat
exchange will occur in the air-cooled condenser.
The units efficiency is maintained as condensing
pressure can be reduced due to air-cooled condenser
becoming oversized. Hot water temperatures up to
70C can be achieved.

Heat recovery
Outdoor Units
Capacity

Power input
EER
Dimensions
Unit
Sound Power
Refrigerant type
Power Supply
Piping connections

Cooling
Cooling during heat recovery
Heat recovery
Cooling
Heat recovery

kW
kW
kW
kW
kW

(Height x Width x Depth)

mm
kg
dBA

Evaporator water inlet/outlet


Heat recovery condenser inlet/outlet
Evaporator water drain

110
107.00
97.70
116.00
43.70
39.40
2.45
1465
89

140
138.00
126.00
148.00
54.00
47.80
2.56
2250x2346x2238
1629
94

160
158.00
144.00
176.00
67.00
62.40
2.36
1723

flexible coupling + counterpipe for welding 3" od


field installation

138

200
191.00
171.00
208.00
81.30
73.20
2.35

280
340
274.00
335.00
251.00
311.00
301.00
377.00
113.00
146.00
103.00
132.00
2.42
2.29
2250x4280x2238
2266
2646
2727
95
96
98
R-407C
3~/400V/50Hz
flexible coupling + counterpipe for welding 3"
2"g
1/4"g

400
379.00
337.00
407.00
163.00
142.00
2.33
4990

460
449.00
401.00
434.00
197.00
177.00
2.28
2250x5901x2238
5113
99

flexible coupling 5"


1/4"g

540
520.00
465.00
441.00
232.00
214.00
2.24
5236

EWAD-MBYN

Air cooled

EWAD170MBYN

STRENGTHS
l DAIKIN stepless single screw compressor.
l Operation down to -15C ambient
temperature.
l Standard reverse phase protection.
l Freeze-up protection and prevention.
l PE treated condenser coil.
l VICTAULIC joints.
l Standard discharge shut-off valve.
l DICN operation as standard within same series.
l Flow switch.
l Modular design.
l High energy efficiency ratio.

ACCESSORIES (kit)
Leaving water control sensor for DICN.
l BMS gateway.
(MODBUS/J-BUS/BACNET protocol).
l Remote user interface (EKRUPC).
l

Low noise
operation

CONTROL
Microprocessor control.
l Water inlet or outlet temperature control.
l Leaving water control sensor for DICN.
l

AVAILABLE INPUTS / OUTPUTS


Input
ON / OFF (per circuit).
l Dual setpoint.
l Pump / flow switch.
l

OPTIONS (factory mounted)


Main isolator switch.
l Condenser protection grilles.
l Low noise (-5 to -7dB(A)).
l Compressor suction stop valve.
l Ampere & Voltmeter
(read-out on switchbox).
l Chilled water temperature down to
- 5C (ZH) or -10C (ZL).
l Hi-ESP fans.
l Dual pressure relief valve.
l

Output
Compressor operation.
l Summary alarm (per circuit).
l Pump relay contact.
l

Cooling only
Outdoor Units
Capacity
Power input
EER
Dimensions
Nominal Water Flow
Unit
Sound Power
Refrigerant type
Power Supply
Piping connections

Cooling
Cooling

kW
kW

(Height x Width x Depth)


Cooling

mm
kPa
kg
dBA

Evaporator water inlet/outlet


Evaporator water drain

120
121
41.1
2.94
31.7
1391
87

150
149
54.1
2.75
2221x3973x1109
18.6
1600
94

3" victaulic coupling

170
171
64.9
2.63

240
226
83.7
2.7

24.8
1705
92

41
2710
90

4" victaulic coupling


1/2" G-F UNI-ISO 228/1

139

300
340
286
330
105
136
2.72
2.43
2250x4280x2238
36.6
49.1
3210
3260
97
95
R-134a
3~/400V/50Hz
5" victaulic coupling

380
372
130
2.86
20.8
5335
97

460
520
449
525
170
210
2.64
2.5
2250x5901x2238
25.6
35.1
5595
5775
98
100

6" victaulic coupling


1/2" G-F UNI-ISO 228/1

600
605
263
2.3
46.6
5855
101

EWAD-AJYNN

Air cooled

EWAD-AJYNN

STRENGTHS
l All models are PED pressure vessel approved
l Stepless single-screw compressor
l Optimised for use with R-134a
l Cooling range: 184600kW
l Eurovent class A: EER up to 2,84
l 2 truly independent refrigerant circuits
l DX shell and tube evaporator one pass
l Refrigerant side to minimize pressure drops
l Several operating sound levels down to 93dB

OPTIONS (factory mounted)


l Single pump
l Twin pump
l High ESP pump
l High ESP twin pump
l Total heat recovery
l Partial heat recovery
l Reduced noise (440-480-500-550-600) /
Low noise
l Fan silent
l Low ambient
l Power factor 0.9
l Gauges
l Coil guards
l Soft starter (400-440-480-500-550-600)
l Blank CU/al coils
l Electronic expansion valve

STANDARD AVAILABLE
Glycol application
l Evaporator heater
l Suction stop valve
l Main switch
l

ACCESSORIES
Communication cards (EKAC200J EKACBAC
- EKACLON)
l Remote user interface (EKRUPCJ)
l Buffer tanks (EKBT500N - EKBTC10N - EKBT500C
- EKBTC500C)
l Sequencing panel (EKCSCII)
l Plant visor (EKPV2J)
l Modem (EKMODEM EKGSMOD)
l Converter RS485 to RS 232 (EKCON)
l

Cooling only
Outdoor Units
Capacity
Power input
Fan

Dimensions
EER
Weight
Sound Power level
Refrigerant type
Power Supply
Piping connections

Cooling
Cooling
Type
Drive
Diameter
Nominal air flow
(Height x Width x Depth)

NON-INVERTER
kW
kW

mm
m/min
mm
kg

190
184.0
81.3

200
197.8
79.6

918
894
2340x2235x2240
2.26
2.48
2380
2466
93.7

230
225.0
84.6

260
245.0
93.5

1374
2.66
2766

Evaporator water inlet/outlet

140

2.62
2766

280
261.0
101.3
Helical
Direct drive
710
1356
2340x2235x3140
2.58
2806
94.3
R-134a
3~/400V/50Hz
4"

300
275.0
108.3

320
298.4
119.4

1338
2.45
2846

2.50
2846

340
321.0
123.4

360
370.0
133.4

1836
2340x2235x4040
2.60
2.77
3166
3186
94.7
97.2

EWAD-AJYNN/Q

Air cooled

EWAD-AJYNN

STRENGTHS
l Standard efficiency extra low noise
l Several operating sound levels down to 84dB
l All models are PED pressure vessel approved
l Stepless single-screw compressor
l Optimised for use with R-134a
l Cooling range: 203500,8kW
l Eurovent class A: EER up to 2,7
l 2 truly independent refrigerant circuits
l DX shell and tube evaporator one pass
l Refrigerant side to minimize pressure drops

OPTIONS (factory mounted)


l Total heat recovery
l Partial heat recovery
l Fan silent
l Power factor 0.9
l Gauges
l Coil guards
l Soft starter (400-440-460-500)
l Blank cu/al coils
l Electronic expansion valve

STANDARD AVAILABLE
l Glycol application
l Evaporator heater
l Suction stop valve
l Main switch

ACCESSORIES
Communication cards (EKAC200J EKACBAC
- EKACLON)
l Remote user interface (EKRUPCJ)
l Buffer tanks (EKBT500N - EKBTC10N - EKBT500C
- EKBTC500C)
l Sequencing panel (EKCSCII)
l Plant visor (EKPV2J)
l Modem (EKMODEM EKGSMOD)
l Converter RS485 to RS 232 (EKCON)

Cooling only
Outdoor Units
Capacity
Power input
Fan

Dimensions
EER
Weight
Sound Power
Refrigerant type
Power Supply
Piping connections

Cooling
Cooling
Type
Drive
Diameter
Nominal air flow
(Height x Width x Depth)

NON-INVERTER
kW
kW

mm
m/min
mm
kg

210
203.0
79.8

240
231.1
85.2

774
2340x2235x3140
2.45
3046
84.3

1074
2.71
3366

Evaporator water inlet/outlet

141

260
252.7
93.7

2.70
3466

280
270.8
104.5
Helical
Direct drive
710

300
286.1
114.5

1032
2340x2235x4040
2.59
2.50
3546
84.7
R-134a
3~/400V/50Hz
4"

320
299.4
126.1

340
308.8
136.3

2.37
3556

2.27

EWAD-AJYNN/A

Air cooled

EWAD-AJYNN

STRENGTHS
l High Efficiency
l Eurovent class A: EER up to 3,21
l All models are PED pressure vessel approved
l Stepless single-screw compressor
l Optimised for use with R-134a
l Cooling range: 247-626,6kW
l 2 truly independent refrigerant circuits
l DX shell and tube evaporator one pass
l Refrigerant side to minimize pressure drops
l Several operating sound levels down to 96dB
STANDARD AVAILABLE
Glycol application
l Evaporator heater
l Suction stop valve
l Main switch
l

OPTIONS (factory mounted)


l Single pump
l Twin pump
l High ESP pump
l High ESP twin pump
l Total heat recovery
l Partial heat recovery
l Fan silent
l Low ambient
l Power factor 0.9
l Low noise
l Gauges
l Coil guards
l Soft starter (500-550-600-650)
l Blank cu/al coils
l Electronic expansion valve
ACCESSORIES
Communication cards (EKAC200J EKACBAC
- EKACLON)
l Remote user interface (EKRUPCJ)
l Buffer tanks (EKBT500N - EKBTC10N - EKBT500C
- EKBTC500C)
l Sequencing panel (EKCSCII)
l Plant visor (EKPV2J)
l Modem (EKMODEM EKGSMOD)
l Converter RS485 to RS 232 (EKCON)
l

Cooling only
Outdoor Units
Capacity
Power input
Fan

Dimensions
EER
Weight
Sound Power
Refrigerant type
Power Supply
Piping connections

Cooling
Cooling
Type
Drive
Diameter
Nominal air flow
(Height x Width x Depth)

NON-INVERTER
kW
kW

mm
m/min
mm
kg
dBA

260
247.0
79.2

280
275.0
87.3

1338
2340x2235x3140
3.21
2866
96.8

1836
3.15
3186

320
301.5
94.2

340
360
327.0
351.0
103.8
112.8
Helical
Direct drive
710
1782
2340x2235x4040
3.15
3.11
3366
3376

3.20
3286
97.2

142

420
401.0
127.5

2640

2580

3.13
3321

3.15
3386
99.7

R-134a
3~/400V/50Hz
4"

Evaporator water inlet/outlet

380
376.0
120.2

EWAD-AJYNN/H

Air cooled

EWAD-AJYNN

STRENGTHS
l High ambient
l Up to 48
l All models are PED pressure vessel approved
l Stepless single-screw compressor
l Optimised for use with R-134a
l Cooling range: 194,6600,4kW
l Eurovent class A: EER up to 3,10
l 2 truly independent refrigerant circuits
l DX shell and tube evaporator one pass
l Refrigerant side to minimize pressure drops
l Several operating sound levels down to 96dB

OPTIONS (factory mounted)


l Single pump
l Twin pump
l High ESP pump
l High ESP twin pump
l Total heat recovery
l Partial heat recovery
l Fan silent
l Power factor 0.9
l Gauges
l Coil guards
l Soft starter (420-460-480-500-550-600)
l Blank cu/al coils
l Electronic expansion valve

STANDARD AVAILABLE
Glycol application
l Evaporator heater
l Suction stop valve
l Main switch
l

ACCESSORIES
Communication cards (EKAC200J EKACBAC
- EKACLON)
l Remote user interface (EKRUPCJ)
l Buffer tanks (EKBT500N - EKBTC10N - EKBT500C
- EKBTC500C)
l Sequencing panel (EKCSCII)
l Plant visor (EKPV2J)
l Modem (EKMODEM EKGSMOD)
l Converter RS485 to RS 232 (EKCON)
l

Cooling only
Outdoor Units
Capacity
Power input
Fan

Dimensions
EER
Weight
Sound power
Refrigerant type
Power Supply
Piping connections

Cooling
Cooling
Type
Drive
Diameter
Nominal air flow
(Height x Width x Depth)

NON-INVERTER
kW
kW

mm
m/min
mm
kg
dBA

200
194.6
77.2

210
208.3
75.6

240
233.5
83.0

1434
1368
2340x2235x2240
2.52
2.76
2380
2466
98.2

260
256.1
91.0

2154
2.81
2766

Evaporator water inlet/outlet

143

280
273.7
97.8
Helical
Direct drive
800
2100
2340x2235x3140
2.80
2806
98.8
R-134a
3~/400V/50Hz
3"

300
289.3
103.9

320
306.4
112.1

340
335.6
120.3

2.73

2874
2340x2235x4040
2.79
2.99
3166
1386
99.2
101

2046
2.78
2846

400
381.2
127.4

EWAD-BJYNN

Air cooled

EWAD-BJYNN

OPTIONS (factory mounted)


l Suction stop valve
l Single pump (650-700-750-850-900-950-
10-11-12-13)
l Twin pump (650-700-750-850-900-950-
10-11-12-13)
l Total heat recovery
l Partial heat recovery
l High ESP fans
l Reduced noise / Low noise
l Fan silent
l Low ambient
l Power factor 0.9
l A/V meter
l Gauges
l Coil guards
l Soft starter
l Blank cu/al coils

STRENGTHS
l All models are PED pressure vessel approved
l Stepless single-screw compressor
l Optimised for use with R-134a
l Cooling range: 6401772kW
l EER range up to 2,93
l 2-3-4 truly independent refrigerant circuits
l Standard electronic expansion valve
l DX shell and tube evaporator one pass
l Refrigerant side to minimize pressure drops
l Several operating sound levels down to 100dB
STANDARD AVAILABLE
Glycol application
l Evaporator heater
l Main switch
l Electronic expansion valve
l

ACCESSORIES
Communication cards (EKAC200J EKACLON)
l Bacnet gateway (EKBMSBNJ)
l Remote user interface (EKRUPCK)
l Buffer tanks (EKBT500N - EKBTC10N - EKBT500C
- EKBTC500C)
l Sequencing panel (EKCSCII)
l Plant visor (EKPV2J)
l Modem (EKMODEM EKGSMOD)
l Converter RS485 to RS 232 (EKCON)
l

NON-INVERTER

Cooling only
Outdoor Units
Capacity
Fan

Dimensions
EER
Weight
Sound Power
Refrigerant type
Power Supply
Piping connections

Cooling
Type
Drive
Diameter
Nominal air flow
(Height x Width x Depth)

kW

mm
m/min
mm
kg
dBA

Evaporator water inlet/outlet

650
640

700
700

750
761

850
817

C10
C11
C12
C13
C14
C15
C16
C18
1057
1109
1166
1226
1322
1520
1641
1772
Helical
Direct drive
800
2850
3168
3486
3798
3870
4434
5160
5070
5382
5700
5802
6966
7602
7740
2520x2230x7400 2520x2230x8270
2520x2230x9200
2520x2230x11000 2520x2230x11900
2520x2230x5310
2520x2230x6210
2.75
2.80
2.81
2.82
2.93
2.76
2.84
2.80
2.80
2.82
2.93
2.81
2.83
2.93
4910
4990
5256
5480
5580
7550
7830
8420
8570
9552
10632
10832
100
101
100
101
102
103
R-134a
R-134a
3~/400V/50Hz
victaulic, diameter 168.3mm
victaulic, diameter 219.1 mm
victaulic, diameter 168.3 mm

144

900
886

950
988

EWAD-BJYNN/Q

Air cooled

EWAD-BJYNN/Q

STRENGTHS
l Standard efficiency extra low noise
l Several operating sound levels down to 86dB
l All models are PED pressure vessel approved
l Stepless single-screw compressor
l Optimised for use with R-134a
l Cooling range: 5381197kW
l EER range up to 2,76
l 2-3-4 truly independent refrigerant circuits
l Standard electronic expansion valve
l DX shell and tube evaporator one pass
l Refrigerant side to minimize pressure drops

OPTIONS (factory mounted)


l Suction stop valve
l Single pump
l Twin pump
l Total heat recovery
l Partial heat recovery
l High ESP fans (550-600-650-700-750-900-
950-10-11-12)
l Power factor 0.9
l A/V meter
l Gauges
l Coil guards
l Soft starter
l Blank cu/al coils

STANDARD AVAILABLE
Glycol application
l Evaporator heater
l Main switch
l Electronic expansion valve
l

ACCESSORIES
Communication cards (EKAC200J EKACLON)
l Bacnet gateway (EKBMSBNJ)
l Remote user interface (EKRUPCK)
l Buffer tanks (EKBT500N - EKBTC10N - EKBT500C
- EKBTC500C)
l Sequencing panel (EKCSCII)
l Plant visor (EKPV2J)
l Modem (EKMODEM EKGSMOD)
l Converter RS485 to RS 232 (EKCON)
l

Cooling only
Outdoor Units
Capacity
Fan

Dimensions
EER
Weight
Sound Power level
Refrigerant type
Power Supply
Piping connections

Cooling
Type
Drive
Diameter
Nominal air flow
(Height x Width x Depth)

NON-INVERTER
kW

mm
m/min
mm
kg
dBA

Evaporator water inlet/outlet

550
538

1536
2520x2230x5310
2.41
5230
86

600
604

650
667

700
725

1692
1848
2520x2230x6210
2.57
2.68
5445
5659
86
86

750
780

1998
2154
2520x2230x7110
2.71
2.73
5900
6030
87
87

victaulic, diameter 168.3

145

800
805

850
893

Helical
Direct drive
800
2526
2460
2520x2230x8300
2.40
2.58
8190
8190
87
87
R-134a
3~/400V/50Hz

900
944

950
1015

2616
2766
2520x2230x9200
2.62
2.74
8725
8725
87
87

C10
1056

C11
1102

3078
2520x2230x10100
2.71
2.71
9310
9310
88
88

victaulic, diameter 219.1

C12
1197

3384
2520x2230x11000
2.76
9750
89

EWAD-BJYNN/A

Air cooled

EWAD-BJYNN

STRENGTHS
l High efficiency
l EER range up to 3,32
l High ambient up to 48(standard noise version)
l All models are PED pressure vessel approved
l Stepless single-screw compressor
l Optimised for use with R-134a
l Cooling range: 6671920kW
l 2-3-4 truly independent refrigerant circuits
l Standard electronic expansion valve
l DX shell and tube evaporator one pass
l Refrigerant side to minimize pressure drops
l Several operating sound levels down to 100dB
STANDARD AVAILABLE
Glycol application
l Evaporator heater
l Main switch
l Electronic expansion valve
l

OPTIONS (factory mounted)


l Suction stop valve
l Single pump (650-700-800-850-900-950-10-1112-13-14-15)
l Twin pump (650-700-800-850-900-950-10-1112-13-14-15)
l Total heat recovery
l Partial heat recovery
l High ESP fans
l Reduced noise / Low noise
l Fan silent
l Low ambient
l Power factor 0.9
l A/V meter
l Gauges
l Coil guards
l Soft starter
l Blank cu/al coils
ACCESSORIES
Communication cards (EKAC200J EKACLON)
l Bacnet gateway (EKBMSBNJ)
l Remote user interface (EKRUPCK)
l Buffer tanks (EKBT500N - EKBTC10N - EKBT500C
- EKBTC500C)
l Sequencing panel (EKCSCII)
l Plant visor (EKPV2J)
l Modem (EKMODEM EKGSMOD)
l Converter RS485 to RS 232 (EKCON)
l

Cooling Only
Outdoor Units
Capacity
Fan

Dimensions
EER
Weight
Sound Power
Refrigerant type
Power Supply
Piping connections

Cooling
Type
Drive
Diameter
Nominal air flow
(Height x Width x Depth)

NON-INVERTER
kW

mm
m/min
mm
kg
dBA

Evaporator water inlet/outlet

650
667

700
723

800
800

850
855

900
903

3486 3798 4116 4434 4512


2520x2230x6210
2520x2230x7110
2.99 3.04 3.09 3.07 3.09
5205 5419 5660 5790 5890
101
100

victaulic, diameter 168.3mm

146

950
926

C10
974

5160
2520x2230x8300
3.23 3.31
6333 6503
101

C11
1038

C12 C13 C14 C15 C16 C17 C18 C19 C20 C21
1094 1177 1222 1282 1354 1430 1557 1710 1806 1920
Helical
Direct drive
800
6036 5700
6336
6966 7098 8400 8232 8868
9030
2520x2230x9200 2520x2230x10100 2520x2230x11000 2520x2230x12800
2520x2230x13670
3.03 3.08 3.12 3.06 3.09 3.12 3.32 2.99 3.07 3.09 3.19
8420
8950
9390 9540 10355 10960 11168 11368 12144
102
103
102
103
R-134a
3~/400V/50Hz
victaulic, diameter 168.3mm victaulic, diameter 219.1mm
victaulic, diameter 219.1mm

EWAD-BJYNN/Z

Air cooled

EWAD-BJYNN

STRENGTHS
l High efficiency and extra low noise
l EER range up to 2.75
l Several operating sound levels down to 86dB
l All models are PED pressure vessel approved
l Stepless single-screw compressor
l Optimised for use with R-134a
l Cooling range: 5691013kW
l 2-3-4 truly independent refrigerant circuits
l Standard electronic expansion valve
l DX shell and tube evaporator one pass
l Refrigerant side to minimize pressure drops

OPTIONS (factory mounted)


Single pump
l Twin pump
l Total heat recovery
l Partial heat recovery
l High ESP fans (600-650-700-950-10)
l Fan silent
l Power factor 0.9
l Suction stop valve
l A/V meter
l Gauges
l Coil guards
l Soft starter
l Blank cu/al coils
l

STANDARD AVAILABLE
Glycol application
l Evaporator heater
l Main switch
l Electronic expansion valve
l

ACCESSORIES
Communication cards (EKAC200J EKACLON)
l Bacnet gateway (EKBMSBNJ)
l Remote user interface (EKRUPCK)
l Buffer tanks (EKBT500N - EKBTC10N - EKBT500C
- EKBTC500C)
l Sequencing panel (EKCSCII)
l Plant visor (EKPV2J)
l Modem (EKMODEM EKGSMOD)
l Converter RS485 to RS 232 (EKCON)
l

Cooling only
Outdoor Units
Capacity
Fan

Dimensions
EER
Weight
Sound power level
Refrigerant type
Power Supply
Piping connections

Cooling
Type
Drive
Diameter
Nominal air flow
(Height x Width x Depth)

NON-INVERTER
kW

mm
m/min
mm
kg
dBA

Evaporator water inlet/outlet

600
569

1848
2520x2230x6210
2.59
5659
86

650
631

700
668

1498
2154
2520x2230x7110
2.62
2.49
5900
6030
86
86

vitaulic, diameter 168.3

147

850
840
Helical
Direct drive
800
2766
2520x2230x9200
2.56
8725
87
R-134a
3~/400V/50Hz

900
914

950
953

3078
2520x2230x10100
2.67
2.60
9310
9310
88
88

vitaulic, diameter 219.1

C10
1013

3384
2520x2230x11000
2.75
9750
88

ERAP-MBYN

Remote evaporator

ERAP-MBYN

STRENGTHS
l DAIKIN stepless single screw compressor.
l Operation down to -15C ambient
temperature.
l Standard reverse phase protection.
l Freeze-up protection and prevention.
l PE treated condenser coil.
l Liquid stop valve.
l Discharge stop valve.
l Standard suction stop valve.
OPTIONS (factory mounted)
l Main isolator switch.
l Condenser protection grilles.
l Low noise (down to -6dB(A)).
l Ampere & Voltmeter
(read-out on switchbox).
l Hi-ESP fans.

ACCESSORIES (kit)
BMS gateway
(MODBUS/J-BUS/BACNET protocol).
l Remote user interface.
l

CONTROL
Return air or room temperature
control.
l Weekly operating schedule.
l

Low noise
operation

AVAILABLE INPUTS / OUTPUTS


Input
ON / OFF.
l Dual setpoint through analog signal.
l Air flow switch.
l Capacity limit.
l

Output
Compressor operation.
l Summary alarm.
l

Cooling only
Outdoor Units
Capacity
Power input
EER
Dimensions
Unit
Sound Power
Refrigerant type
Power Supply
Piping connections

Cooling
Cooling

kW
kW

(Height x Width x Depth)

mm
kg
dBA

ERAP110MBY
114.00
42.10
2.71

ERAP150MBY
150.00
52.40
2.86
2250x2346x2238
1440

1326
91

ERAP170MBY
171.00
65.20
2.62
1516
96

R-407C
3~/400V/50Hz
2" 1/8
7/8"
compressor: 1"npt

Suction line connection


Liquid line connection
Relief device outlet

148

D.I.C.N.
Daikin Integrated Chiller Network

Applicable Series:




EWAP110-540MBYN (R-407C)
EWTP110-540MBYN (R-407C)
EWAD120-340MBYN (R-134a)
EWWD120-540MBYN (R-134a)
EWLD120-540MBYN (R-134a)

Daikin stepless screw chillers can be equipped with DICN which allows the simultaneous operation of up to 4 chillers as if they were a single
unit, in order to deliver the required cooling capacity. This results in precise and efficient capacity control and is also useful for back up
purposes, ensuring that the necessary amount of cooling is available and guaranteeing reliable operation of the chiller plant.
This function enables a Daikin 2MW chiller plant to be operated via a single controller.
Please note that DICN is only possible within the same series.

149

EHMC
Hydraulic module

STRENGTHS
100l buffer tank.
Freeze-up protection (heater tape).
Single pump.
12l expansion vessel.
Standard dual pressure ports.

EHMC10-15-30AV1010

Pump characteristics
1 - EHMC30AV1080
2 - EHMC10AV1080 & EHMC15AV1080
3 - EHMC30AV1010
4 - EHMC10AV1010 & EHMC15AV1010
Hydraulic module + filter pressures losses
5 - EHMC15/30AV1010 & EHMC15/30AV1080
6 - EHMC10AV1010 & EHMC10AV1080

hydraulic module
EHMC10AV
1010
Nominal flow
Nominal static height
Nominal input
Dimensions (HxWxD)
Machine weight
Sound power
Sond pressure
Power supply
Operation range
Piping connections

l/min
mH2O
W
mm
kg
dBA
dBA
V1
Water side
CDB
Air side
CDB
Evaporator water inlet/outlet
Drain connection

EHMC15AV
1080

1010

62
17
630

1010

88
34
1,050

15
650

101

102

1,284x635x688
99

EHMC30AV
1080
27
1,070

10
1,070

104

105

1,284x635x688

63
52

63
52
230V/1~/50Hz
-10C ~ 55C
-10C ~ 43C
2 BSPF
1/2

1 BSPF

150

1080
187
27
2,090
1,284x635x688
111
63
52

2-1/2 BSPF

EWWP-KAW1N

Water cooled

EWWP014-035KAW1N

STRENGTHS
l One of the most compact units in the market
(60cm x 60cm x 60cm for models 014 to 035).
l Daikin scroll compressor.
l Standard reverse phase protection.
l Extension possible up to 195kW.

CONTROL
Microprocessor control.
l Water inlet temperature control.
l Cold water or hot water regulation.
l

AVAILABLE INPUTS/OUTPUTS

For single module units


l Standard main isolator switch.
l Basic hydraulic components for KA-series included
with the unit as a kit: flow switch, air purge, filter +
shut-off valves for both condenser and evaporator.
OPTIONS (factory mounted)
Chilled water temperature down to
- 5C (OPZH) or -10C (OPZL).

Input
Remote ON/OFF.
Pump contact.
Cool/heat selection.
Output
Compressor operation.
Summary alarm.
Pump relay contact.
The range of chillers EWWP014-065KAW1 can be
extended up to 195kW in a modular way.

ACCESSORIES (kit)
l Compressor soundproof material (-3dBA).
l Hydraulic module (see page 28).
l BMS gateway (MODBUS/J-BUS / BACNET
protocol).
l Remote user interface.

Units EWWP090-195KAW1 is a combination of up


to 3 modules EWWP045-065KAW1, combined with
control box ECB2/3MUW.
For configuration guidelines, see below table or
contact your local DAIKIN supplier.

Cooling only/heating only


Outdoor Units
Capacity
Power input
EER
Dimensions
Unit
Sound Power
Refrigerant type
Power Supply
Piping connections

Low noise
operation

NON-INVERTER

Cooling
Cooling

kW
kW

014
13.0
3.61
3.5

(Height x Width x Depth)

mm
kg
dBA

118

022
028
21.5 28.0
5.79 7.48
3.61
600x600x600
155
165
64

035
32.5
8.75
3.57
172
71

045
055
065
090
43.0
56
65.0 86.0
11.8 15.5 17.6 23.6
3.55
3.5
3.55
600x600x1200
300
320
334
600
67
74
71

100
110
120
99.0
112
121
27.3 31.0 33.1
3.52
3.5
3.53
1200x600x1200
620
640
654
71
75
R-407C

3N~/400V/50Hz
Evaporator water inlet/outlet
Condensor water inlet/outlet

fbsp 25
fbsp 25

130
130
35.2
-

145
142
39.1
3.53

155
155
42.8
3.51

668
77

920

940
73

165
175
168
177
46.5 48.6
3.5
3.52
1800x600x1200
960
974
76

3N~/400V/50Hz
fbsp 40
fbsp 40

151

2 x 2 x fbsp 38
2 x 2 x fbsp 38

3 x 2 x fbsp 38
3 x 2 x fbsp 38

185
186
50.7
3.54

195
195
52.8
3.55

988
78

1002
79

EWWP-KAW1N

Water cooled

EWWP014-035KAW1N

EWWP090-130KAW1N

EWWP145-195KAW1N

SELECTION TABLE

1 MODULE (KA-series)

Capacity index
Cooling capacity (kW)
Heating capacity (kW)

UNIT
+
CONTROL
(factory mounted)

UNIT ONLY
(Without Control)
CONTROL
(Kit)

EWWP014KAW1N
EWWP022KAW1N
EWWP028KAW1N
EWWP035KAW1N
EWWP045KAW1N
EWWP055KAW1N
EWWP065KAW1N
EWWP045KAW1M
EWWP055KAW1M
EWWP065KAW1M
ECB 1 MUW
ECB 2 MUW
ECB 3 MUW

2 MODULES (KA-series)

3 MODULES (KA-series)

014
13

022
21.5

028
28

035
32.5

045
43

055
56

065
65

090
86

100
99

110
112

120
121

130
130

145
142

155
155

165
168

175
177

185
186

195
195

16

26.2

35.3

41

52.5

71

81

105

124

142

153

164

176

195

213

224

235

246

1
-

1
-

1
-

1
-

1
1
1
-

1
1
1
-

1
1
1
-

2
-

1
1
1
-

2
1
-

1
1
1
-

2
1
-

2
1
1

1
2
1

3
1

2
1
1

1
2
1

3
1

For example: for a 121 kW -HP system, select :



EWWP055KAW1

+ EWWP065KAW1

152

1
-

EWLP-KAW1N

Remote condenser

EWLP014KAW1N

CONTROL
Microprocessor control.
l Water inlet temperature control.

STRENGTHS
l One of the most compact units in the market
(60cm x 60cm x 60cm for models 012 to 030).
l Daikin scroll compressor.
l Standard main isolator switch.
l Basic hydraulic components : included as a kit with
the unit: flow switch, air purge, filter + shut-off
valves.
l Standard reverse phase protection.

Low noise
operation

AVAILABLE INPUTS/OUTPUTS
Input
Remote ON / OFF.
l Pump contact.
l

Output
Compressor operation.
l Summary alarm.
l Pump relay contact.

OPTIONS (factory mounted)


l Chilled water temperature down to
- 5C (ZH) or -10C (ZL).

ACCESSORIES (kit)
Compressor soundproof material (-3dBA).
l Hydraulic module (see page 28).
l BMS gateway (MODBUS/J-BUS /
BACNET protocol).


l Remote user interface.
l

Cooling only
Outdoor Units
Capacity
Power input
EER
Dimensions
Unit
Sound Power
Refrigerant type
Power Supply
Piping connections

NON-INVERTER

Cooling
Cooling

kW
kW

012
12.1
4.2
2.88

(Height x Width x Depth)

mm
kg
dBA

108

Evaporator water inlet/outlet


Evaporator water drain
Liquid line connection
Discharge line connection

020
20.0
6.6
2.99
141
64

026
26.8
8.5
3.08

030
31.2
10.1
3.06

040
40.0
13.4
2.96

147

151
71
R-407C
3N~/400V/50Hz

252

055
53.7
17.8
2.98
600x600x1200
265

600x600x600

9.52 flare
12.7 flare

fbsp 25
field installation
12.7 flare
19.1 flare

153

67

fbsp 40
field installation
2x12.7 flare
2x19.1 flare

065
62.4
20.3
3.04
274
74

EWWD-MBYN
Water cooled

EWWD120MBYN

STRENGTHS
l Compact and modular design.
l DAIKIN stepless single screw compressor.
l Standard reverse phase protection.
l VICTAULIC joints.
l DICN operation as standard within same series.
l Standard discharge shut-off valve.
l Standard filter, flow switch.

CONTROL
Microprocessor control.
l Water inlet or outlet temperature control.
l Weekly operating schedule.
l

Low noise
operation

AVAILABLE INPUTS/OUTPUTS
Input
ON / OFF.
l Pump contact.
l Dual setpoint through analog signal.
l Floating setpoint.
l

OPTIONS (factory mounted)


Main isolator switch.
l Low noise (-5 to -7dB(A)).
l Compressor suction stopvalve.
l Ampere & Voltmeter
(read-out on switchbox).
l Chilled water temperature down to
- 5C (ZH) or -10C (ZL).
l Dual pressure relief valve.
l

Output
Compressor operation.
l Summary alarm (per circuit).
l Pump relay contact.
l

ACCESSORIES (kit)
BMS gateway (MODBUS/J-BUS / BACNET
protocol).
l Remote user interface (EKRUPC).
l

Cooling only/heating only


Outdoor Units
Capacity
Power input
EER
COP
Dimensions
Unit
Sound Power
Refrigerant type
Power Supply
Piping connections

Cooling
Heating
Cooling
Heating

(Height x Width x Depth)

Evaporator water inlet/outlet


Condensor water inlet/outlet
Condensor water drain
Relief device outlet

kW
kW
kW
kW

mm
kg
dBA

120
123.00
147.00
28.70
34.50
4.29
4.26

180
240
183.00
249.00
216.00
290.00
45.20
61.60
54.00
72.80
4.05
4.04
4
3.98
1018x2681x930
1273
1527
95

1000
91

280
273.00
327.00
69.20
83.40
3.95
3.92
1623
96

3" od victaulic
2" 1/2 victaulic
1x1"

2x1"

154

360
366.00
431.00
90.50
108.00

440
432.00
505.00
107.00
127.00
4.04

3.99

3.98

2546
2800
98
R-134a
3~/400V/50Hz
3" victaulic
3" victaulic
m6
3x1"

500
498.00
580.00
123.00
146.00
4.05
3.97
2000x2681x930
3034
99

520
522.00
617.00
131.00
156.00
3.98
3.96

540
546.00
655.00
138.00
167.00
3.96
3.92

3150

3346

4x1"

EWLD-MBYN

Remote condenser

EWLD120MBYN

STRENGTHS
l DAIKIN stepless single screw compressor.
l Compact and modular design.
l Standard phase sequence controller.
l VICTAULIC joints.
l DICN operation as standard within

same series.
l Standard discharge shut-off valve.
l Standard flow switch.
l Standard filter.
OPTIONS (factory mounted)
l Main isolator switch.
l Low noise (-6dB(A)).
l Compressor suction stop valve.
l Ampere and Voltmeter (read-out
on switchbox).
l Chilled water temperature down to
- 5C (ZH) or -10C (ZL).
l Dual pressure relief valve.

ACCESSORIES (kit)
BMS gateway (MODBUS/J-BUS /
BACNET protocol).
l Remote user interface.
l

Low noise
operation

CONTROL
Microprocessor control.
l Water inlet or outlet temperature control.
l Weekly operating schedule.

AVAILABLE INPUTS/OUTPUTS
Input
ON / OFF.
l Pump contact.
l Dual setpoint through analog signal.
l Floating set point.
l

Output
Compressor operation.
l Summary alarm.
l Fan-condenser relay contacts.
l Pump relay contact.
l

Cooling only
Outdoor Units
Capacity
Power input
EER
Dimensions
Unit
Sound Power
Refrigerant type
Power Supply
Piping connections

Cooling
Cooling

kW
kW

(Height x Width x Depth)

mm
kg
dBA

Evaporator water inlet/outlet


Liquid line connection
Discharge line connection
Relief device outlet

120
116.00
32.00
3.63

170
240
170.00
235.00
49.80
66.50
3.41
3.53
1018x2681x930
1110
1342
95

891
91

3" od victaulic
7/8"

1" 1/8
2" 1/8

260
265.00
77.90
3.4
1428
96

1" 3/8
2" 5/8
2x1"

1x1"

155

340
340.00
99.60
3.41

400
405.00
116.00
3.49

2220
2452
98
R-134a
3~/400V/50Hz
3" victaulic
2x1/8"
1"1/8 + 1"3/8
2x(2"1/8)
3x1"

480
470.00
133.00
3.53
2000x2681x930
2684
99

500
500.00
144.00
3.47

540
530.00
156.00
3.4

2770

2856

2x1" 3/8
2" 1/8 + 2" 5/8
4x1"

2x(2"5/8)

EWWD-DJYNN
Water cooled

EWWD-DJYNN

OPTIONS (factory mounted)


l Total heat recovery
l Partial heat recovery
l Power factor 0.9
l A/V meter
l Low noise
l Soft starter
l Cu/ni heat exchanger

STRENGTHS
l All models are PED pressure vessel approved
l Stepless single-screw compressor
l Optimised for use with R-134a
l Cooling range: 165.5555.7kW
l EER range up to 4
l 1-2 truly independent refrigerant circuits
l Standard electronic expansion valve
l DX shell and tube evaporator one pass
l Refrigerant side for easy oil circulation and return

ACCESSORIES
Communication cards (EKAC200J EKACLON)
l Bacnet gateway (EKBMSBNJ)
l Remote user interface (EKRUPCK)
l Buffer tanks (EKBT500N - EKBTC10N - EKBT500C
- EKBTC500C)
l Sequencing panel (EKCSCII)
l Plant visor (EKPV2J)
l Modem (EKMODEM EKGSMOD)
l Converter RS485 to RS 232 (EKCON)
l

STANDARD AVAILABLE
Glycol application
l Suction stop valve
l Main switch
l Gauges
l Electronic expansion valve
l

Cooling Only
Outdoor Units
Capacity
Dimensions
EER
Weight
Refrigerant type
Power Supply

Cooling
(Height x Width x Depth)

NON-INVERTER
kW
mm
kg

170
165.5
3.93
1393

210
260
201.2
252.8
1860x3435x920
3.97
3.90
1410
1503

300
280.4

320
333.9

380
372.2

3.72
1503

3.96
2687

4.00
2697

R-134a
3~/400V/50Hz

156

420
460
402.5
448.3
1880x4305x860
3.97
3.89
2702
2757

500
493.7

600
555.7

3.83
2762

3.70
2762

EWWD-DJYNN/A
Water cooled

EWWD-DJYNN

STRENGTHS
l High efficiency
l EER range up to 4,7
l All models are PED pressure vessel approved
l Stepless single-screw compressor
l Optimised for use with R-134a
l Cooling range: 186.4603.9kW
l 1-2 truly independent refrigerant circuits
l Standard electronic expansion valve
l DX shell and tube evaporator one pass
l Refrigerant side for easy oil circulation and return

OPTIONS (factory mounted)


l Total heat recovery (190-230-28-320-380-
400-460-500)
l Partial heat recovery
l Power factor 0.9
l A/V meter
l Low noise
l Soft starter
l Cu/ni heat exchanger
ACCESSORIES
Communication cards (EKAC200J EKACLON)
l Bacnet gateway (EKBMSBNJ)
l Remote user interface (EKRUPCK)
l Buffer tanks (EKBT500N - EKBTC10N - EKBT500C
- EKBTC500C)
l Sequencing panel (EKCSCII)
l Plant visor (EKPV2J)
l Modem (EKMODEM EKGSMOD)
l Converter RS485 to RS 232 (EKCON)
l

STANDARD AVAILABLE
Glycol application
l Suction stop valve
l Main switch
l Gauges
l Electronic expansion valve
l

Cooling Only
Outdoor Units
Capacity
Dimensions
EER
Unit
Refrigerant type
Power Supply

Cooling
(Height x Width x Depth)

NON-INVERTER
kW
mm
kg

190
186.4
4.70
1650

230
280
223.3
276.5
1860x3435x920
4.64
4.66
1665
1680

320
306.7

380
366.3

400
408.2

4.30
1680

4.62
2800

4.68
2945

R-134a
3~/400V/50Hz

157

460
500
443.6
496
1880x4305x860
4.67
4.73
2955
2975

550
540.5

650
603.9

4.72
2990

4.39
2990

EWWD-CJYNN
Water cooled

STRENGTHS
l All models are PED pressure vessel approved
l Stepless single-screw compressor
l Optimised for use with R-134a
l Cooling range: 3341893kW
l EER up to 4.64
l 1-2-3-4 truly independent refrigerant circuits
l Standard electronic expansion valve
l DX shell and tube evaporator one pass
l Refrigerant side to minimize pressure drops

ACCESSORIES
Communication cards (EKAC200J EKACLON)
l Bacnet gateway (EKBMSBNJ)
l Remote user interface (EKRUPCK)
l Buffer tanks (EKBT500N - EKBTC10N - EKBT500C
- EKBTC500C)
l Sequencing panel (EKCSCII)
l Plant visor (EKPV2J)
l Modem (EKMODEM EKGSMOD)
l Converter RS485 to RS 232 (EKCON)
l

STANDARD AVAILABLE
Glycol application
l Main switch
l Gauges
l Electronic expansion valve
l

Cooling Only
Outdoor Units
Capacity
Dimensions
EER
Weight
Refrigerant type
Power Supply

Cooling
(Height x Width x Depth)

EWWD-CJYNN

OPTIONS (factory mounted)


Total heat recovery
l Partial heat recovery
l Power factor 0.9
l Suction stop valve
l A/V meter
l Soft starter
l Cu/ni heat exchanger
l

NON-INVERTER
kW
mm
kg

340
334

400 480
399
462
1970x3310x900
4.12 4.43 4.49
1830 1855 1886

550
510
4.64
1965

700
666

750 800 900 950 C10


735
792
871
934 1074
2070x4300x1290
4.16 4.30 4.40 4.47 4.51 4.28
3395 3495 3515 3560 3590 4960
R-134a

3~/400V/50Hz

C11 C12 C13 C14 C15 C16 C17 C18 C19


1139 1205 1268 1331 1394 1525 1629 1761 1893
2320x3770x2160
2320x5151x2240
4.35 4.41 4.45 4.47 4.51 4.43 4.45 4.50 4.55
4980 5110 5135 5175 5205 6790 6830 6830 6940
3~/380-440V/50Hz

158

EWWD-BJYNN
Water cooled

EWWD-BJYNN

STRENGTHS
l All models are PED pressure vessel approved
l 1 and 2 stepless single-screw compressors
l Optimised for use with R-134a
l Cooling range: 3691050kW
l Super high efficiency: EER up to 5,83
l Very high EER values at part loads condition
l Flooded evaporator
l Expansion valve with liquid level control
STANDARD AVAILABLE
Main switch
l Gauges
l Electronic expansion valve
l

OPTIONS (factory mounted)


l Glycol application
l Suction stop valve
l A/V meter
l Soft starter
l Cu/ni heat exchanger
ACCESSORIES
Communication cards (EKAC200J EKACLON)
l Bacnet gateway (EKBMSBNJ)
l Remote user interface (EKRUPCK)
l Buffer tanks (EKBT500N - EKBTC10N - EKBT500C
- EKBTC500C)
l Sequencing panel (EKCSCII)
l Plant visor (EKPV2J)
l Modem (EKMODEM EKGSMOD)
l Converter RS485 to RS 232 (EKCON)
l

Cooling Only
Outdoor Units
Capacity
Power input
Dimensions
EER
Weight
Refrigerant type
Power Supply

Cooling
Cooling
(Height x Width x Depth)

NON-INVERTER
kW
kW
mm
kg

380
369
65
2250x3625x1551
5.68
3089

460
550
445
521
77.9
90
2250x3960x1551
5.71
5.79
3070
3603

159

750
850
734
816
129
142
2300x4145x1743
5.65
5.71
5546
5636
R-134a
3~/400V/50Hz

900
895
155
2300x4145x1808
5.77
6007

C10
C11
976
1050
167
180
2300x4145x1910
5.81
5.83
6448
6598

FWV/FWL
FWM/FWD
FWB
Fan coil units

5 models, of which 3 in flexible application


available in 2-pipe and 4-pipe
fashionable design
wide range of options
to be combined with water chiller or boiler
washable air filter

FWB02AT

FWV02C**

FWL03C**

FWM01C**

FWD04A**

FWL03C**

FWM01C**

FWD04A*

FWB02-10AT
COOLING
HEATING
Power input
Dimensions (HxWxD)
Machine weight
Sound power level (H/L)
Heat exchanger
Fan
Available pressure
No. of speeds
Water connections
Power supply

Total capacity
Sensible capacity
Heating capacity (2-pipe) (H)
Heating capacity (4-pipe) (H)

No. of rows
Air flow rate (H)

kW
kW
kW
kW
kW
mm
kg
dBA
m3/h
Pa

02

03

04

05

2.61
1.88
5.47
3.14
106

3.14
2.16
6.01
3.14
106
239x1,039x609
24
58/36
4
400
71

3.49
2.34
6.47
3.14
106

5.08
3.6
10.31
5.99
192

23
58/36
3

26
58/36
6

inch
Y1

06

07

5.45
6.47
3.87
4.4
11.39
12.28
5.99
5.99
192
192
239x1,389x609
31
33
35
60/37
60/37
60/37
3
4
6
800
65
7 speeds (High = 7, medium = 4, low = 1)
3/4
230V/1~/50Hz

08

09

10

7.57
5.23
15.05
12.8
294

8.67
5.96
16.85
12.8
294
239x1,739x609
45
69/53
4
1,200
59

10.34
6.9
18.78
12.8
294

43
69/53
3

48
69/53
6

Measuring conditions COOLING 2-pipe: air: 27CDB/19CWB - entering water 7C - leaving water 12C HEATING 2-pipe: air: 20CDB - entering water 70C - leaving water 60C
Sound power level according to ISO3741 - sound pressure calculated at 1.5m distance - Q=2

160

FWV/FWL/FWM01-10C**

2-pipe (**=TN or TV)

COOLING

HEATING

Power input
Coil water volume
Air flow
Sound power level
Weight

2- pipe / 4-pipe

4-pipe(**=FN)

COOLING

HEATING

Power input
Air flow
Sound power level
Weight

Water connections
Max. absorbed current
Dimensions
Power supply

Total capacity (H)


Sensible capacity (H)
Water flow
Pressure drop
Heating capacity (H)
Water flow
Pressure drop
H

kW
kW
l/h
kPa
kW
l/h
kPa
W
l
H/M/L
m3/h
H/M/L
dBA
FWV
kg
FWM
kg
FWL
kg
Total capacity (H)
kW
Sensible capacity (H)
kW
Water flow
l/h
Pressure drop
kPa
Cooling coil water volume l
Heating capacity (H)
kW
Water flow
l/h
Pressure drop
kPa
Heating coil water volume l
H
W
H/M/L
m3/h
H/M/L
dBA
FWV
kg
FWM
kg
FWL
kg
inch
W
FWV/FWL
mm
FWM
mm
V/ ~ /Hz

01

02

03

1.54
2.09
1.20
1.51
265
359
13
13
2.14
2.57
265
359
9
10
37
53
0.5
0.7
319/233/178
344/271/211
45/39/33
50/44/38
19
20
14
15
20
21
1.46
1.90
1.14
1.51
251
327
13
13
0.5
0.7
1.90
2.10
196
182
7
8
0.2
0.2
37
53
307/225/174
327/261/205
45/39/33
50/44/38
20
21
15
16
21
22
1/2"
1/2"
0.17
0.24
564x774x226
535x584x224

04

2.93
2.11
504
11
3.81
504
9
56
1
442/341/241
47/41/33
25
19
27
2.87
2.07
494
11
1
3.08
286
5
0.3
56
431/332/238
47/41/33
26
20
28
1/2"
0.25
564x984x226
535x794x224

06

4.33
4.77
3.15
3.65
745
820
12
14
5.63
6.36
745
820
9
10
98
98
1.4
1.4
706/497/361
785/605/470
52/43/35
56/49/43
30
31
23
23
32
33
4.33
4.67
3.15
3.57
745
803
12
14
1.4
1.4
5.05
5.30
396
465
10
10
0.4
0.4
98
98
690/490/356
763/593/460
52/43/35
56/49/43
32
33
25
25
34
35
1/2"
1/2"
0.44
0.43
564x1,194x226
535x1,004x224
230/1/50

08

10

6.71
8.02
4.91
5.96
1,154
1,343
12
19
7.83
10.03
1,154
1,343
9
16
182
244
2.1
2.1
1,011/771/570
1,393/1,022/642
61/54/47
66/59/49
41
41
32
32
44
44
6.64
7.88
4.85
5.85
1,142
1,355
12
19
2.1
2.1
7.91
9.30
694
816
8
9
0.6
0.6
182
244
998/765/565
1,362/1,007/636
61/54/47
66/59/49
44
44
34
34
46
46
3/4"
3/4"
0.80
1.12
564x1,404x251
535x1,214x249

** = TN (2-pipe, without valves), TV (2-pipe, with valves), FN (4-pipe, without valves).

FWD04-18A*
2-pipe (*=T)

COOLING

HEATING

2- pipe / 4-pipe

4-pipe (*=F)

Available static pressure


Weight
COOLING

HEATING

Available static pressure


Weight
Air flow rate
Power input
Water connections
Max. absorbed current
Dimensions
Sound power level
Power supply

Total capacity
Sensible capacity
Water flow (H)
Pressure drop (H)
Heating capacity
Water flow (H)
Pressure drop (H)

Total capacity
Sensible capacity
Water flow (H)
Pressure drop (H)
Heating capacity
Water flow (H)
Pressure drop (H)

kW
kW
l/h
kPa
kW
l/h
kPa
Pa
kg
kW
kW
l/h
kPa
kW
l/h
kPa
Pa
kg
m3/h
W
inch
W
mm
dBA
V/ ~ /Hz

04

06

08

10

12

16

18

3.90
3.08
674
17
4.05
674
14
66
33
3.90
3.08
674
17
4.49
349
9
63
35
800
234
3/4
0.95
280x754x559
66

6.20
4.65
1,064
24
7.71
1,064
20
58
41
6.20
4.65
1,064
24
6.62
581
15
53
43
1,250
349
3/4
1.58
280x964x559
69

7.80
6.52
1,339
24
9.43
1,339
20
68
47
7.80
6.52
1,339
24
9.21
808
13
63
50
1,600
443
3/4
1.97

8.82
7.16
1,514
16
10.79
1,514
13
64
49
8.82
7.16
1,514
16
9.21
808
13
59
52
1,600
443
3/4
1.97

11.90
9.36
2,056
26
14.45
2,056
21
97
65
11.90
9.36
2,056
26
15.86
1,392
12
92
71
2,200
714
1
3.21
352x1,174x718
74

16.4
12.8
2,833
34
19.81
2,833
28
145
77
16.4
12.8
2,833
34
21.15
1,856
16
138
83
3,000
1,197
1
5.37

18.3
14.1
3,140
45
21.92
3,140
37
134
80
18.3
14.1
3,140
45
21.15
1,856
16
128
86
3,000
1,197
1
5.37

280x1,174x559
72

72
230/1/50

352x1,384x718
78

78

Measuring conditions (at nominal air flow and ESP) COOLING Air temperature entering the unit: 27C/19C Water temperature entering the unit 7C Water temperature rise 5K
HEATING Room air temperature: 20C For 2 pipe units: Water inlet temperature 50C - Water flow rate same as for the cooling test For 4 pipe units: - Water inlet temperature 70C - Water temperature decrease 10K

161

POWER Supply
T1 = 3~, 220V, 50HZ
V1 = 1~, 220-240V, 50HZ
VE = 1~, 220-240V, 50HZ/60HZ
V3 = 1~, 230V, 50HZ
VM = 1~, 220~240V/220~230V, 50HZ/60HZ
W1 = 3N~, 400V, 50HZ
Y1 = 3~, 400V, 50HZ

MEASURING Conditions
COOLING ONLY
1) nominal cooling capacities are based on:
indoor temperature
outdoor temperature
refrigerant piping length
level difference

27CDB/19CWB
35CDB
7.5m - 8/5m VRV
0m

HEAT PUMP
1) nominal cooling capacities are based on:
indoor temperature
outdoor temperature
refrigerant piping length
level difference
2) nominal heating capacities are based on:
indoor temperature
outdoor temperature
refrigerant piping length
level difference

27CDB/19CWB
35CDB
7.5m - 8/5m VRV
0m
20CDB
7CDB/6CWB
7.5m - 8/5m VRV
0m

CHILLERS:
Air-cooled

cooling only
heat pump

Water-cooled

cooling only
heating only

Remote condenser
Remote evaporator

cooling capacity/power input conditions

Fan coil units

cooling
heating

evaporator: 12C/7C
ambient: 35CDB
evaporator: 12C/7C
ambient: 35C
condenser: 40C/45C
ambient: 7CDB/6CWB
evaporator: 12C/7C
condenser: 30C/35C
evaporator: 12C/7C
condenser: 40C/45C
evaporator: 12C/7C
condensing temperature: 45C / liquid temperature: 40C
suction dew point: 5C
ambient: 35C
superheat: 10C
room temperature: 27C/19C
entering water temperature: 7C/12C
room temperature: 20C
water inlet temperature: 50C (2-pipe)/70C (4-pipe)

The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value, depending on the distance and acoustic environment (for measuring
conditions: please refer to the technical databooks).
The sound power level is an absolute value indicating the power which a sound source generates.
For more detailed information please consult our technical databooks.

162

1571UK_pp162-164.indd 162

24/7/07 13:29:56

Infrared remote control


Infrared remote control with LCD to start, stop and regulate the air conditioner from a distance.

Auto fan speed


Automatically selects the necessary fan speed to reach or maintain the set temperature.

Wired remote control


Wired remote control to start, stop and regulate the air conditioner from a distance.

Fan speed steps


Allows to select up to the given number of fan speed.

Centralised control
Centralised control to start, stop and regulate several air conditioners from one central point.

Timer
Allows to preset the air conditioner to start/stop at a specied time.

Vertical auto swing


Possibility to select automatic vertical moving of the air discharge louvre, for uniform air ow and
temperature distribution.

24 Hour timer
Timer can be set to start cooling/heating anytime during a 24-hour period.

Horizontal auto swing


Possibility to select automatic horizontal moving of the air discharge louvre, for uniform air ow and
temperature distribution.

Night set mode


Saves energy, by preventing overcooling or overheating during night time.

Draught prevention
When starting to warm up or when the thermostat is off, the air discharge direction is set horizontally
and the fan to low speed, to prevent draught. After warming up, air discharge and fan speed are
set as desired.

Ceiling soiling prevention


A special function prevents air blowing out too long in horizontal position, to prevent ceiling stains.

Auto-restart
The unit restarts automatically at the original settings after power failure.

Self-diagnosis
Simplies maintenance by indicating system faults or operating anomalies.

Auto cooling-heating changeover


Automatically selects cooling or heating mode to achieve the set temperature
(heat pump types only).

Scroll compressor
Silent, reliable Daikin compressor used in medium sized outdoor units.

Dry programme
Allows humidity levels to be reduced without variations in room temperature.

Single screw compressor


Compact, high efcient, silent reliable Daikin compressor.
Maintenance free (inspection only after 40,000 hours of operation)

Fan only
The air conditioner can be used as fan, blowing air without cooling or heating.

Econo mode
This function decreases the power consumption so that other applicances that need large power
consumption can be used. This function is also energy saving.

163

1571UK_pp162-164.indd 163

24/7/07 13:29:57

Energy efficiency
Daikin air conditioners are energy efcient and economical.

Powerful mode
If the temperature in the room is too high/low, it can be cooled down/heated quickly by selecting the
powerful mode. After the powerful mode is turned off, the unit returns to the preset mode.

Whisper quiet
Daikin indoor units are whisper quiet. Also the outdoor units are guaranteed not to disturb the quiet
of the neighbourhood.

Movement sensor
The sensor detects whether someone is in the room. When the room is empty, the unit switches to
economy mode after 20 minutes and restarts when a person enters the room.

Double thermostat function


Controls the temperature via a sensor on the air conditioner or via a sensor on the remote control.

Comfortable sleeping mode


Increased comfort function that follows a specic temperature uctuation rhythm.

Air filter
Removes airborne dust particles to ensure a steady supply of clean air.

Home leave operation


During absence, the indoor temperature can be maintained at a certain level.

Air purification filter


Removes airborne dust particles and prevents the propagation of bacteria and viruses to ensure a
steady supply of clean air.

Outdoor unit silent operation


Lowers the operation sound of the outdoor unit by 3dB(A) to ensure a quiet environment for the
neighbourhood.

Photocatalytic deodorising filter


Removes airborne dust particles, decomposes odours and restrains the reproduction of bacteria, viruses,
microbes, this to ensure a steady supply of clean air.

Indoor unit silent operation


Lowers the operation sound of the indoor unit by 3dB(A). This function is useful when studying or
sleeping.

Drain pump kit


Facilitates condensation draining from the indoor unit.

Night quiet mode (cooling only)


Lowers the operation sound of the outdoor unit automatically by 3dB(A) by removing a jumper
wire on the outdoor unit. This function can be deactivated if the jumper wire is reinstalled on the
outdoor unit.

Twin/triple/double twin application


2, 3 or 4 indoor units can be connected to only 1 outdoor unit even if they have different capacities. All
indoor units operate within the same mode (cooling or heating) from one remote control.

Comfort mode
The new ap changes the discharge angle horizontally for cooling operation and downward vertically for
heating operation. This in order to prevent cold or warm air from blowing directly on the body.

Multi model application


Up to 5 indoor units (even different capacities) can be connected to a single outdoor unit. All indoor
units can individually be operated within the same mode.

3-D Air flow


This function combines Vertical and Horizontal auto-swing to circulate a stream of cool/warm air right
to the corners of even large spaces.

Super multi plus


Up to 9 indoor units (even different capacities and up to 71 class) can be connected to a single outdoor
unit. All indoor units can individually be operated within the same mode.

164

1571UK_pp162-164.indd 164

24/7/07 13:29:58

Daikin Airconditioning UK Ltd

Daikin Airconditioning UK Ltd

Head Office

General Catalogue 2007

Daikin Airconditioning UK Limited


The Heights, Brooklands, Weybridge, Surrey KT13 0NY

1st July 2007

Tel 0845 6419000 Fax 0845 6419109

General Catalogue 2007

www.daikin.co.uk

Daikin units comply with the European regulations that


guarantee the safety of the product.

ISO14001 assures an effective environmental management


system in order to help protect human health and the
environment from the potential impact of our activities,
products and services and to assist in maintaining and
improving the quality of the environment.

Daikin Europe N.V. participates in the Eurovent Certification


Programme for Air Conditioners (AC), Liquid Chilling Packages (LCP)
and Fan Coil Units (FC); the certified data of certified models are
listed in the Eurovent Directory. Multi units are Eurovent certified for
combinations up to 2 indoor units. VRV, rooftop and FWD-units are not
within the scope of the Eurovent Certification Programme.

Daikin products are distributed by:

www.daikin.co.uk

The present catalogue is drawn up by way of information only


and does not constitute an offer binding upon Daikin Europe N.V..
Daikin Europe N.V. has compiled the content of this catalogue to
the best of its knowledge. No express or implied warranty is given
for the completeness, accuracy, reliability or fitness for particular
purpose of its content and the products and services presented
therein. Specifications are subject to change without prior notice.
Daikin Europe N.V. explicitly rejects any liability for any direct or
indirect damage, in the broadest sense, arising from or related
to the use and/or interpretation of this catalogue. All content is
copyrighted by Daikin Europe N.V..

UKEPCEN07-500 / 06.07 / Swim / La Movida


The present publication supersedes EPCEN07-500_P
Printed by Portishead Press using vegetable oil based inks, on 75% recycled paper.

issue one

Daikin Europe N.V. is approved by LRQA for its Quality


Management System in accordance with the ISO9001
standard. ISO9001 pertains to quality assurance regarding
design, development, manufacturing as well as to services
related to the product.

issue one