WHAT IS DVC ?
DVC (Damodar Valley Corporation)a legacy to the
people of India, emerged as a culmination of attempts
made over a whole century to control the wild and
erratic Damodar river. The river spans over an area of
24,235 km2 covering the states of Jharkhand
(Dhanbad, Bokaro, Hazaribagh, Koderma, Giridih,
Chhatra, Palamau, Rachi, Lohardaga and Doomka) &
West Bengal (Burdwan , Hooghly, Howrah, Bankura and
Purulia).

OBJECTIVES/PURPOSE :
FLOOD CONTROL.
IRRIGATION.
WATER SUPPLY- INDUSTRIAL AND DOMESTIC.
NAVIGATION & DRAINAGE.
GENERATION, TRANSMISSION
ELECTRICAL ENERGY.

AND

DISTRIBUTION

OF

AFFORESTATION AND CONTROL OF SOIL EROSION.


PROMOTION
OF
PUBLIC
HEALTH,
AGRICULTURE,
INDUSTRIAL, ECONOMIC AND GENERAL WELL BEING IN
THE VALLEY.

LANDMARKS ACHIEVED :

DVC- FIRST MULTIPURPOSE RIVER VALLEY PROJECT BY THE GOVT. OF INDIA.


DVC- ORGANIZATION GENERATING POWER THROUGH THREE SOURCES- COAL, WATER AND
LIQUID FUEL.
FIRST UNDERGROUND HYDEL STATION- MAITHON.
BTPS- NATIONS BIGGEST THERMAL POWER PLANT IN THE 50S OF THE LAST CENTURY
BTPS BOILERS- FIRST TO BURN UNTAPPED LOW-GRADE COAL IN PULVERIZED FUEL
FURNACES.
CTPS- THE FIRST RE-HEAT UNITS IN INDIA, UTILIZING HIGH STEAM PARAMETER.
MTPS- FIRST OF ITS KIND IN EASTERN INDIA WITH TUBE MILLS IN SERVICE FOR ZERO
REJECT. DIRECT IGNITION OF PULVERIZED COAL (DIPC) SYSTEM FOR REDUCING OIL
CONSUMPTION IN THE BOILER.

-: DVC Infrastructure At A Glance :DVC COMMAND AREA


24,235 SQ. KMS
POWER MANAGEMENT
TOTAL INSTALLED
2796.5 MW
CAPACITY
THERMAL POWER
STATIONS

FIVE CAPACITY 2570


MW

HYDEL POWER STATIONS

THREE CAPACITY 144


MW

GAS TURBINE STATION

ONE CAPACITY 82.5


MW

SUB-STATIONS AND
RECEIVING STATIONS

AT 220 KV 11 NOS.
AT 132 KV 33 NOS.
AT 33 KV 16 NOS.

TRANSMISSION LINES

220 KV 1500 CKT


KMS
132 KV 3415 CKT
KMS

DVC POWER PLANTS AT A GLANCE


NAME

BOKARO 'B'
CHANDRAPURA

LOCATION
THERMAL
DIST .- BOKARO
STATE JHARKHAND
DIST .- BOKARO
STATE JHARKHAND

DURGAPUR

DIST .- BARDDHAMAN
STATE - WEST BENGAL

MEJIA

DIST .- BANKURA
STATE - WEST BENGAL

DSTPS

DIST .- BARDHAMAN
STATE - WEST BENGAL
DIST .- KODERMA
STATE JHARKHAND

KTPS
TOTAL THERMAL

CAPACITY
630 MW
(3 X 210 MW)
890MW
(3 X 130 MW)
+
(2 X 250 MW)
350 MW
(1X140 MW)
+
(1X210 MW)
2340 MW
(4 X 210 MW)
+
(2 X 250 MW)
+
(2 X 500 MW)
1000 MW
(2 X 500 MW)
500 MW
(1 X 500 MW)
5710 MW

NAME

LOCATION

EXISTING CAPACITY

HYDEL
TILAIYA

MAITHON

PANCHET

RIVER - BARAKAR
DIST .- HAZARIBAGH
STATE JHARKHAND
RIVER - BARAKAR
DIST .- BURDHAMAN
STATE - WEST BENGAL
RIVER - DAMODAR
DIST .- DHANBAD
STATE JHANKHAND

TOTAL HYDEL

GRAND TOTAL (THERMAL + HYDEL)

4 MW
(2 X 2 MW)
63.2 MW
(2 X 20 MW)
+
(1 X 23.2 MW)
80 MW
(2 X 40 MW)
147.2 MW

5857.2 MW

DAMS

MAITHON DAM
KEY OBJECTIVES

FLOOD
CONTOL

GENERATION OF
ELECTRIC POWER

IRRIGATIO
N

NAVIGATIO
N&
DRAINAGE

WATER
SUPPLY TO
INDUSTRIE
S AND
DOMESTIC
S

Maithon Hydel
MAITHON HYDEL POWER STATION (MHPS) IS LOCATED ON THE RIVER
BARAKAR.
FIRST UNDERGROUND POWER STATION.
GENERATING CAPACITY OF 60 MW.
MHPS -1000 FEET BELOW THE WATER LEVEL.

TRAINING AT

MAITHON HYDEL POWER


STATION
220 KV KALYANESHWARI
SUBSTATION
CENTRAL LOAD DISPATCH

ON
OVERVIEW

Power Generation

Entrusted with the responsibilities of


providing the vital input power for industrial
growth in the resource rich DamodarValley
region, DVC hasbeen practically operating as a
pioneer,using latest available technologies to
supply bulk power at reasonable rates to
themajor industries.

DVC has maintained its lead role in the


eastern region by
adopting itself to the
challenges of time and technology during the
course of last 59 years. DVC has been generating
and transmitting power since 1953 and has
succeeded not only in meeting the needs of
consumers but has also helped to increase the
demand of power which itself is an index of
development.

MAITHON HYDEL POWER STATION


Maithon Hydal Power Station is
located on the river Barakar 12.9
km above its confluence with the
Damodar near the border of
Dhanbad and Burdwan districts of
the state of Jharkhand and West
Bengal respectively. The unique
feature of this hydal power station
is that it is located underground in
the left bank of the river and is the
first of its kind in India. The Power
station has a total generating
capacity of 60 MW with 3 units of
20 MW each.

HowHydropower Works

WATER TURBINE:
water turbines are used to convert
theenergy offalling water intomechanical
energy.

PENSTOCK:
It is a closed conduit which connects the fore bay or surge tank to the scroll
case of the turbine.

Maithon Hydel Station At A Glance


1. Drainage area 2430 sq . mile
2. Inflow(maximum) 2500 cusec
3. Annual rainfall(max) 70 inch
4. Annual rainfall(avg.) 30.5 inch
5. Area design 28400 al
6. Length of back water 15 miles
7. Major reservoir level 86-500h
8. Gross strong capacity 104,0000 Al H
9. Flood control reservoir 440000 Al H
10. Monsoon storage capacity 496000 Al H
11. Estimated cost of station 4.71 crores

20 Mw Generator Specification
1. Simmens Sehuckert,Germany
2. 3PH,generator no.D73445
3. Type-PFL 670/47-34
4. Y11,000 volt,1310/1525amp
5. RPM-176.6
6. KVA-25000/29000
7. P.F-0.8 const.
Excitor Specification
1. V: 295/330/445
2. A: 465/505/700
Main Excitor
1. DC GEN. NO-D39408
2. TYPE-GV 441/36
3. V-310,333,500
4. RPM-176.6

SINGLE LINE DIAGRAM OF HYDEL POWER STATION

MEASURING INSTRUMENT USED


ENERGY METER - To measure the energy
transmitted energy meters are fitted to the panel to
different feeders the energy transmitted is recorded
after one hour regularly for it MWHr, meter is
provided

WATTMETERS - It is attached to each feeder to


record the power exported from DVC.

FREQUENCY METER - To measure the frequency at


each feeder there is the provision of analog or
digital frequency meter.

FREQUENCY METER - To measure the frequency at each feeder


there is the provision of analog or digital frequency meter.
VOLTMETER - It is provided to measure the phase to phase
voltage .It is also available in both the analog and digital frequency
meter.
AMMETER - It is provided to measure the line current. It is also
available in both the forms analog as well as digital.

MAXIMUM DEMAND INDICATOR - There are also


mounted the control panel to record the average
power over successive predetermined period
MVAR METER - It is to measure the reactive power
of the circuit

GENERATED POWER

ELECTRIC POWER
TRANSMISSION
ELECTRIC-POWER TRANSMISSION IS THE BULK TRANSFER
OF ELECTRICAL ENERGY, FROM GENERATING POWER PLANTS
TO ELECTRICAL SUBSTATION LOCATED NEAR DEMAND
CENTERS.

HAT IS AN ELECTRIC SUBSTATION?


A SUBSTATION IS A PART OF AN ELECTRICAL GENERATION, TRANSMISSION
AND DISTRIBUTION SYSTEM. SUBSTATIONS TRANSFORM VOLTAGE FROM
HIGH TO LOW, OR THE REVERSE, USING STEP-UP OR STEP-DOWN
TRANSFORMERS.

ELEMENTS OF A SUBSTATION A:PRIMARY POWER LINES' SIDE B:SECONDARY


POWER LINES' SIDE 1.PRIMARY POWER LINES 2.GROUND WIRE 3.OVERHEAD LINES
4.TRANSFORMER FOR MEASUREMENT OF ELECTRIC VOLTAGE 5.DISCONNECT
SWITCH 6.CIRCUIT BREAKER 7.CURRENT TRANSFORMER 8.LIGHTNING ARRESTER
9.MAIN TRANSFORMER 10.CONTROL BUILDING 11.SECURITY FENCE 12.SECONDARY

220KV KALYANESWARI SUB-STATION

220KV SYSTEM (12 BAYS)


1)
2)
3)
4)
5)
6)

220KV LINES: L#228(KALYANESWARI-MTPS)


L#229(KALYANESWARI-MTPS)
L#203(KALYANESWARI-CTPS)
L#204(KALYANESWARI-CTPS)
L#217(KALYANESWARI-PGCIL, PITHAKARI)
L#218(KALYANESWARI-PGCIL, PITHAKARI)

BUS COUPLER: - 02 NOS.


BUS TIE BAY:-01NO.

AUTOTRANSFORMERS:

ATR#1CGL MAKE 150MVA, 220KV/132KV


ATR#2 CGL MAKE 150MVA, 220KV/132KV
ATR#3 BHEL MAKE 150MVA, 220KV/132KV

132KV SYSTEM (11 BAYS)


132KV LINES: 1) L# 18(KLN-KLP)
2) L# 19KLN-KLP)
3) L# 68(MHS-KLN)
4) L# 69(MHS-KLN)
5) MAL-IMPEX FDR (CD 61MVA)

BUS COUPLER: - 01 NO.

AUTOTRANSFORMERS: 1) ATR#1CGL MAKE 150MVA, 220KV/132KV


2) ATR#2 CGL MAKE 150MVA, 220KV/132KV
3) ATR#3 CGL MAKE 150MVA, 220KV/132KV
TWO WINDING TRANSFORMERS:1) 50 MVA, 132/33KV, APEX MAKE.
2) 31.5MVA, 132/33KV, TELK MAKE.

33KV SYSTEM
NAME OF THE CONSUMERS:
1) IMPEX STEEL (PVT) LTD.(CD-7.0MVA)
SUBSTATIO
2) HIRA CONCUST STEEL PVT LTD (CD-7.0MVA)
N
3) CITY ALLOYS PVT. LTD. (CD-3.0MVA)
4) BMA STAINLESS LIMITED (CD-12.0MVA)
5) JAGDAMBA ISPAT PVT LIMITED (CD-3.0MVA)
6) MAA LILORI ISPAT LTD. (CD- 3.0MVA)
SWITCHYA
CONTROL
7) CHHABRA ISPAT PVT. LTD.(CD 8MVA)
RD
BUILDING

SUBSTATION PARTS AND EQUIPMENT

OUTDOOR
SWITCHYARD
INCOMING & OUTGOING LINES

BUSBARS
POWER TRANSFORMERS AND MEASUREMENT TRANSFORMERS
INSULATORS
CIRCUIT-BEAKERS & ISOLATORS
LIGHTNING ARRESTORS
GALVANISED STEEL STRUCTURES FOR TOWERS & EQUIPMENT SUPPORTS.
ROADS, RAILWAY TRACK, CABLE TRENCHES
PLCC EQUIPMENT INCLUDING LINE TRAP, TUNING UNIT, COUPLING CAPACITOR, ETC.
STATION EARTHING SYSTEM COMPRISING GROUND MAT, RISERS, AUXILIARY MAT,
EARTHING STRIPS, EARTHING SPIKES & EARTH ELECTRODES.
CONTROL CABLES FOR PROTECTION AND CONTROL

CONTROL BUILDING

IN EVERY SUB-STATION CERTAIN SUPERVISION, CONTROL AND PROTECTION FUNCTIONS


ARE NECESSARY. SO A CONTROL BUILDING/CONTROL ROOM IS REQUIRED. THE RELAY
AND PROTECTION PANELS AND CONTROL PANELS ARE INSTALLED IN THE CONTROL
ROOM.
CONTROL IN SUB-STATION ARE OF TWO CATEGORIES.
1. NORMAL ROUTINE OPERATION BY OPERATORS COMMAND.
2. AUTOMATIC OPERATION BY ACTION OF PROTECTIVE RELAYS AND CONTROL SYSTEM

FUNCTIONS OF CONTROL ROOM

1. ALARM FUNCTIONS
2. CONTROL AND INDICATION
3. DATA COLLECTION, RECORDING,
TRANSFORMERS
PRESENT IN KALYANESHWARI SUBSTATION
DISPLAY
150 MVA 220/132KV AUTO-TRANSFORMER
Make BHEL
Year of manufacture: 2003
Type of cooling: ONAN/ONAF/OFAF
Rating HV & LV (VA)- 75/ 105/ 50
( 50%/75%/100%)
Rating LV - 10/ 14/20
(50%/70%/100%)
Temp rise oil- 40 C (Over Ambient of 50 )
Temp rise winding- 45 (Over Ambient of 50 )
Purchase order Ref- PE-SPEC-719(R)/581257
Dated 03.12.02
Maker Sl No- 6006080
Elect Spec No- 601098
Phase 3
Frequency 50 Hz
Connection Symbol- YNa0d1
Impedance Volt at 150MVA Base
HV Position (1/IV)12.6% to 16.24%
HV Position (9b/IV)
14.1% to 15.5%
HV Position (17/IV)
13% to 16.77%

No Load Voltage HV (Kv)-230


No Load Voltage IV (Kv)- 138
No Load Voltage LV (Kv)-6.9
Line Current HV (Amps)-188.5/263.9/377.0
Line Current LV (Amps)- 314.2/439.8/628.3
Line Current LV (Amps)- 837.8/1172.9/1675.5
Insulation Level:
HV- L1 950AC 395-L1 170 AC 70
IV- L1550AC 275
LV-L1 75AC 26.9
Diagram DRG No- 34631900019
OGA DRG No- 3463000066
Core and winding (Kg)- 59700
Weight of oil (Kg)- 38280
Total weight (Kg)-140365
Oil quantity (L)- 44000
Transport Weight (Kg)-79000
Undertaking weight (Kg) 59700

CURRENT TRANSFORMER (CT):

MAKE ELECTRIC POWER EQUIPMENT CO.


MSR INDUSTRIES ESTATE, BANGALORE 560054
TYPE OHCDB-R
HSV 36KV
SERIAL NO. 33193
FREQ 50 HZ.
RATED VOLTAGE 33KV
SHORT TIME THERMAL CURRENT 15.15KA FOR 3 SECS
25.24KA FOR 1 SECS
INSULATION 70/170KV
QTY OF OIL/WT. 20 LTR./ 24 KG APRX.
DYNAMIC CURRENT 65.6 KAP
YEAR 1999
TOTAL WT. 150 KGS (APRX)
MAX. TEMP. RISE - WINDING - 45C
INSULATION A
OVER AMBIENT (45C) OIL - 40C
CONTINUOUS THERMAL CURRENT 780 A

Instrume
nt
transfor
mer
Current
transfor
mer

POTENTIAL TRANSFORMER (PT):


MAKE MODERN ELECTRONIC
TYPE OPT
RATIO 33KV3 / 1103V /1103V.
HSV 36KV,
PHASE 1,
FREQ- 50 HZ
INSULATION CLASS A
CORE I
II
BURDEN - 100
100
CLASS 0.2
3P
V.F 1.2 CONT. & 1.9 FOR 30 S
CONN PH E
BIL 70/170KV
TEMP. RISE OVER WDG OIL
45C 35C
OIL QTY. 20 LTR.
TOTAL WT. 90KG
ISS 3156,
SL. NO.- ME/PT/411/08
P.O NO. CE(T)/P 4/ST BB/2087

Potential
transfor
mer

Circuit Breakers:
MAIN FUNCTION OF CIRCUIT BREAKER IS TO SWITCH OFF AND SWITCH ON
THE NORMAL CURRENT AND TOP TRIP THE CIRCUIT AT THE OCCURANCE OF
ANY FAULT.

CIRCUIT BREAKERS USED IN THIS SUBSTATION:


MINIMUM OIL CIRCUIT BREAKER
SF6 CIRCUIT BREAKER
SF CIRCUIT BREAKER (220KV SYSTEM) DETAILS :
Type - 3AP1F1
Year of Manufacturing/No - 2006/IND/01/2276
Rated Voltage
245 kV
Rated lightning impulse withstand voltage
1050 kVP
Rated Power Freq. withstand voltage
460 kV
Rated Frequency
50 Hz
Rated Normal Current
3150 A
Rated S. Circuit breaking current
40kA
Rated S. Circuit Duration
S
Rated out of phase breaking current

Isolators:
ISOLATORS GIVE PHYSICAL SEPARATION BETWEEN LIVE
PART AND DEAD PART. PHYSICAL SEPARATION CAN BE
SEEN BY NAKED EYE FROM A DISTANCE.

Surge/Ligthning Arrestors (LA):


SINGLE POLE UNITS CONNECTED BETWEEN BUSBAR AND
GROUND. HIGH VOLTAGE SURGES CAUSED BY LIGHTNING
OR SWITCHING ARE DISCHARGED EFFECTIVELY TO
EARTH.

Bus bars:

BUSBARS ARE CONDUCTORS OF ADEQUATE


CROSS-SECTION, SUPPORTED ON INSULATORS

PROTECTION & CONTROL:


Objectives of Protection:
I) TO DISCONNECT THE FAULTY CIRCUIT WITH MINIMUM
DAMAGE DUE TO FAULT.
II) TO LEAVE THE REST OF THE POWER SYSTEM IN A HEALTHY
STATE.
III) COST OF REPAIR OF DAMAGE TO BE KEPT MINIMUM.
IV) TO RESTRICT POSSIBILITY OF SPREADING AND INVOLVING
OTHER EQUIPMENT.
V) TO REDUCE TIME THE EQUIPMENT OUT OF SERVICE.
VI) TO MINIMIZE COST OF REVENUE LOSS.
Characteristic of Protection:
I) VERY FAST
II) SELECTIVE
III) SENSITIVE
III) STABLE UNDER EXTERNAL FAULT