You are on page 1of 6

Shear Calculation

Check Tri al Depth for one-way shear (Along X Axis)


Critical Load Case = #5
Shear Force (S)= 582.75 kN
S hear Stress (Tv)= 343.078914 kN/ m^2
Percentage of Steel(Pt) = 0.2566
As Per IS 456 2000 Clause 40 Table 19
She r Strength of Concrete (Tc) = 1005.98 kN/m^2
Tv< Tc hence, safe.

Check Trial Depth for one-way shear (Along Z Axis)


Critical Load Case = #5
Shear Force (S)= 573.75 kN
Shear Stress (Tv)= 337.778591 kN/m^2
Percentage of Steel(Pt)= 0.2479
As Per IS 456 2

000 Clause 40 Table 19

Shear Strength of Concrete

(Tc)= 1005.98 kN/m^ 2

Tv< Tc hence, safe.


Check Trial Depth for two-way shear
Critical Load Case = #5
Shear Force(S) = 1640.97 kN
Shear Stress(Tv) = 1083.55 kN/m^2
As Per IS 456 2000 Clause 31.6.3.1
Ks = 1.00
Shear Strength(Tc)= 1369.3064 k N/m^2
Ks x Tc = 1369.3064 kN/m^2
T v<= Ks x Tc hence, safe

Reinforcement Calculation

Calculation of Maximum Bar Size

Along X Axis
Bar diameter corresponding to m ax bar size (db) = 25.0 00 mm
As Per IS 456 2000 Clause 26.2.1
Development Length h(ld)=db*0.87fy /4*bd =1.47m
Allowable Length (ldb) =B-b/2-cc =1.63m
ldb >ld hence, safe.

Along Z Axis
Bar diameter corresponding to max bar size(db) = 25.0 00 mm
As Per IS 456 2000 Clause 26.2.1
Development Length h(ld)=db*0.87fy /4*bd =1.47m
Allowable Length (ldb) =B-b/2-cc =1.68m
ldb >ld hence, safe.
Bottom Reinforcement Design
Along Z Axis

For moment w.r.t. X Axis (Mx)


As Per IS 456 2000 Claus e 26.5.2.1
Critical Load Case = #5
Minimum Area of Steel (Ast min) = 2289.12 mm2
Calculated Area of Steel (Ast) = 4359.21 mm2

Provided area of steel (Ast, provided) = 4359.205mm2


Ast min<=Ast, provided Steel area is accepted.
Selected bar Dia = 10.000
Minimum spacing allowed (Smin) = 50.000 mm
Selected spacing (S) = 67.091 mm
Smin <= S <= Smax and selected bar size < selected maximum bar size...
The reinforcement is accepted.
Based on spacing reinforcement increment; provided reinforcement is
#10 @ 65.000 mm o.c.

Along X Axis

For moment w.r.t. Z Axis (Mz)


As Per IS 456 2000 Clause 26.5.2.1

Critical Load Case = #5


Minimum Area of Steel (Astmin) = 2289.12 mm2
Calculated Area of Steel (Ast) = 4210.337 mm2
Provided Area of Steel (Ast, Provided) = 4210.337 mm2
Astmin<= Ast, Provided Steel area is accepted

Selected bar Dia = 10.000


Minimum spacing allowed (Smin) = = 50.000 mm
Selected spacing (S) = 69.62 mm
Smin <= S <= Smax and selected bar size < selected maximum bar size...
The reinforcement is accepted.
Based on spacing reinforcement increment; provided reinforcement is
#10 @ 65.000 mm o.c.

Top Reinforcement Design


Along Z Axis

Minimum Area of Steel (Astmin) = 2289.120 mm2


Calculated Area of Steel (Ast) = 2284.560 mm2

Provided Area of Steel (Ast, Provided) = 2289.120 mm2


Astmin<= Ast, Provided Steel area is accepted
Governing Moment = 0.000 kNm

Selected Bar Dia = 8.000


Minimum spacing allowed (Smin) = 50.000 mm
Selected spacing (S) = 82.044 mm
Smin <= S <= Smax and selected bar size < selected maximum bar size...
The reinforcement is accepted.
Based on spacing reinforcement increment; provided reinforcement is
#8 @ 80.000 mm o.c.

Along X Axis

Minimum Area of Steel (Astmin) = 2289.120 mm2


Calculated Area of Steel (Ast) = 2284.560 mm2
Provided Area of Steel (Ast, Provided) = 2289.120 mm2
Astmin<= Ast, Provided Steel area is accepted
Governing Moment = 0.000 kNm

Selected Bar Dia = 8.000


Minimum spacing allowed (Smin) = = 50.000 mm
Selected spacing (S) = 82.044 mm
Smin <= S <= Smax and selected bar size < selected maximum bar size...
The reinforcement is accepted.
Based on spacing reinforcement increment; provided reinforcement is
#8 @ 80.000 mm o.c.