You are on page 1of 4

Street & Area Lighting Deemed Calculation Method

The purpose of the spreadsheet is to provide the user with a method to calculate the annual energy savings resulting from the
installation of more energy efficient street or area lighting. This spreadsheet also computes the Conservation and Renewable
Energy Rate Discount Credit associated with these savings. The user must provide three inputs: 1) The type of lamp and watta
of the existing fixture, 2) the type of lamp and wattage of the replacement fixture; and, 3) the annual operating hours of the lam
not photo-sensor controlled.
Line No.
Inputs
1 Enter Existing Lamp Type

Metal Halide

2
3
4
5
6

Low Pressure Sodium

Enter Replacement Lamp


Enter Existing Lamp Wattage (Lamp & Ballast)
Enter Replacement Lamp Wattage (Lamp & Ballast)
Estimated Existing Lumens
Estimated Replacement Lumens

(Max for your choice-750)


(Max for your choice-250)

7 Is this fixture controll by a photo-sensing device?


8 Default hours of operation for photo sensor controlled lights
9 Enter Operating Hours for Non-Photo Sensor Controlled Lights
Results
10 Wattage Reduction
11 Annual Energy Savings (kWh)
12 Conservation and Renewable Resources Rate Discount Credit

35
27

(If line 7 is 'No' insert actual hours on li

Method

ual energy savings resulting from the


s the Conservation and Renewable
inputs: 1) The type of lamp and wattage
the annual operating hours of the lamp if

Metal Halide
Low Pressure Sodium

500
200
35,500
27,000
No

e 7 is 'No' insert actual hours on line 9)


4,100

300
1,230
281.23

2
Photo Controlled
Yes
No
4
Existing Lamp Type
High Pressure Sodium
Incandescent
Mercury Vapor
Metal Halide
2
Replacement Lamp Type
High Pressure Sodium
Low Pressure Sodium
Mercury Vapor
Metal Halide
35,500
1
2
3
4

Existing Watts=>
High Pressure Sodium
Incandescent
Mercury Vapor
Metal Halide

500

Lumens
46,200
7,900
20,300
35,500
27,000

1
2
3
4

New Watts=>
High Pressure Sodium
Low Pressure Sodium
Mercury Vapor
Metal Halide

200

Lumens

Lumen Output
High Pressure Sodium
Incandescent
Low Pressure Sodium
Metal Halide
Mercury Vapor

Lamp Wattage^4
Lamp Wattage^3
-0.0000021125
0.0018209042
0.0000000251
-0.0000482884
0.0000275695
-0.0107339204
-0.0000008227
0.0014170426
0.0000000572
-0.0000995982

15,000
27,000
6,600
9,200

500
1500
1250
750

500
250
1250
750
Lamp Wattage^2
Lamp Wattage
Intercept
-0.4176611321 115.1661151613 -2561.6060482097
0.0474956626
0.3149843695
330.3502286587
1.6049439973
23.5618130798
-137.7545096771
-0.6240389298 138.8373756429 -3613.4246132905
0.0422969106
43.3778009036 -3069.1373077412