You are on page 1of 12

$ Generated by PRO/II Keyword Generation System <version 9.2.

1>
$ Generated on: Thu Oct 22 12:39:37 2015
TITLE PROJECT=TESIS, PROBLEM=Val Shortcut, USER=MS and LE,
SITE=HOME
DESC Validacin del sistema termodinamico para las torres de
destilacion
DESC del proceso de purificacin y recobro de etileno.
DESC Sistema Termodinamico: Predictive Peng-Robinson 78
DESC Autores: Luis Embus
DESC

Michael Sutherland

DESC
DIMENSION ENGLISH, STDTEMP=60.0008, STDPRES=14.6959
SEQUENCE SIMSCI
CALCULATION TVPBASIS=100, RVPBASIS=APIN
COMPONENT DATA
LIBID 1,H2/2,N2, BANK=SIMSCI,PROCESS
LIBID
3,CO/4,METHANE/5,ETHYLENE/6,ETHANE/7,PROPENE/8,PROPANE/ &
9,BUTANE/10,PENTANE/11,HEXANE, BANK=SIMSCI
ASSAY FIT=ALTERNATE, CONVERSION=API94, CURVEFIT=CURRENT, &
KVRECONCILE=TAILS, FORMATION=CURRENT
THERMODYNAMIC DATA
METHOD SYSTEM=PRH, TRANSPORT=PETR, SET=PRH01, DEFAULT
STREAM DATA
PROPERTY STREAM=60, TEMPERATURE=-80, PRESSURE=425,
PHASE=M, &
COMPOSITION(M,LBM/H)=1,2.6/2,1.7/3,0.3/4,55/5,152.3/6,127.6/
&

7,1.1/8,0.3/9,0.2
PROPERTY STREAM=54, TEMPERATURE=-30, PRESSURE=425,
PHASE=M, &
COMPOSITION(M,LBM/H)=1,7.7/2,4.3/3,0.9/4,141.1/5,293.2/ &
6,526.2/7,32.7/8,9.1/9,33.8/10,14.2/11,6.9
PROPERTY STREAM=80, TEMPERATURE=38, PRESSURE=396,
PHASE=M, &
COMPOSITION(M,LBM/H)=4,0.2/5,443.3/6,653.7/7,33.8/8,9.4/ &
9,34/10,14.2/11,6.9
PROPERTY STREAM=94, TEMPERATURE=8, PRESSURE=325,
PHASE=M, &
COMPOSITION(M,LBM/H)=4,0.2/5,443.3/6,653.7/7,0.6/8,0.1
OUTPUT FORMAT=PROPLIST, STREAMS=66, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=76, SPTPRINT=ON
OUTPUT FORMAT=Flujos por comp, STREAMS=66,76, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=88, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=98, SPTPRINT=ON
OUTPUT FORMAT=Flujos por comp, STREAMS=88,98, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=80, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=54,60, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=94, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=115, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=122, SPTPRINT=ON
OUTPUT FORMAT=Flujos por comp, STREAMS=115,122,
SPTPRINT=ON
FORMAT IDNO=Flujos por
comp,SID,NAME,PHASE,DOUBLINE,TEMP,PRESSURE, &
VFRAC,LFRAC,RATE(M),TEXT,CRATE(M),TEXT

UNIT OPERATIONS
COLUMN UID=T62, NAME=Demetanizadora
PARAMETER TRAY=37,IO=50
FEED 60,3/54,8
PRODUCT OVHD(M)=66,215.9, BTMS(M)=76, SUPERSEDE=ON
CONDENSER TYPE=PART, TEST=-147
DUTY 1,1,,CONDENSER
DUTY 2,37,,REBOILER
PSPEC PTOP=400
PRINT PROPTABLE=PART
ESTIMATE MODEL=CONVENTIONAL, RRATIO=2.1148, CTEMP=-147
SPEC ID=COL1SPEC1, RRATIO, PHASE=L, VALUE=2.1148
SPEC ID=COL1SPEC2, STREAM=66, RATE(LBM/H), COMP=4,WET,
DIVIDE, &
REFFEED, RATE(LBM/H), COMP=4,WET, VALUE=0.9989
VARY DNAME=CONDENSER,REBOILER
REBOILER TYPE=KETTLE
COLUMN UID=T82, NAME=Deetanizador
PARAMETER TRAY=47,IO
FEED 80,14
PRODUCT OVHD(M)=88,1097.9, BTMS(M)=98, SUPERSEDE=ON
CONDENSER TYPE=PART, TEST=18
DUTY 1,1,,CONDENSER
DUTY 2,47,,REBOILER
PSPEC PTOP=350, DPTRAY=0.05
PRINT PROPTABLE=PART
ESTIMATE MODEL=CONVENTIONAL, RRATIO=0.6754, CTEMP=18, &

RTEMP=203
TEMPERATURE 47,203
SPEC ID=COL2SPEC1, RRATIO, PHASE=L, VALUE=0.6754
SPEC(CHANGE) ID=COL2SPEC2, STREAM=88, RATE(LBM/H),
COMP=6,WET, &
DIVIDE, STREAM=80, RATE(LBM/H), COMP=6,WET, &
VALUE=0.99
SPEC ID=COL2SPEC3, TRAY=47, TEMPERATURE(F), VALUE=203
VARY DNAME=CONDENSER,REBOILER
REBOILER TYPE=KETTLE
COLUMN UID=T100
PARAMETER TRAY=102,IO
FEED 94,41
PRODUCT OVHD(M)=115,441.9, BTMS(M)=122, SUPERSEDE=ON
CONDENSER TYPE=BUBB, TEST=-18
DUTY 1,1,,CONDENSER
DUTY 2,102,,REBOILER
PSPEC PTOP=300
PRINT PROPTABLE=PART
ESTIMATE MODEL=CONVENTIONAL, RRATIO=5.62, CTEMP=-18
SPEC ID=COL3SPEC1, RRATIO, PHASE=L, VALUE=5.62
SPEC ID=COL3SPEC2, STREAM=115, RATE(LBM/H), COMP=5,WET,
DIVIDE, &
STREAM=94, RATE(LBM/H), COMP=5,WET, VALUE=0.9959
SPEC(CHANGE) ID=COL3SPEC3, STREAM=122, RATE(LBM/H),
COMP=6,WET, &
DIVIDE, STREAM=94, RATE(LBM/H), COMP=6,WET, &
VALUE=0.99

VARY DNAME=CONDENSER,REBOILER
REBOILER TYPE=KETTLE
END

Panag ried rec

$ Generated by PRO/II Keyword Generation System <version 9.2.1>


$ Generated on: Thu Oct 22 12:44:37 2015
TITLE PROJECT=TESIS, PROBLEM=Val Shortcut, USER=MS and LE,
SITE=HOME
DESC Validacin del sistema termodinamico para las torres de
destilacion
DESC del proceso de purificacin y recobro de etileno.
DESC Sistema Termodinamico: Predictive Peng-Robinson 78
DESC Autores: Luis Embus
DESC

Michael Sutherland

DESC
DIMENSION ENGLISH, STDTEMP=60.0008, STDPRES=14.6959
SEQUENCE SIMSCI
CALCULATION TVPBASIS=100, RVPBASIS=APIN
COMPONENT DATA
LIBID 1,H2/2,N2, BANK=SIMSCI,PROCESS
LIBID
3,CO/4,METHANE/5,ETHYLENE/6,ETHANE/7,PROPENE/8,PROPANE/ &
9,BUTANE/10,PENTANE/11,HEXANE, BANK=SIMSCI
ASSAY FIT=ALTERNATE, CONVERSION=API94, CURVEFIT=CURRENT, &
KVRECONCILE=TAILS, FORMATION=CURRENT
THERMODYNAMIC DATA

METHOD SYSTEM=PRM, TRANSPORT=PETR, SET=PRM01, DEFAULT


STREAM DATA
PROPERTY STREAM=60, TEMPERATURE=-80, PRESSURE=425,
PHASE=M, &
COMPOSITION(M,LBM/H)=1,2.6/2,1.7/3,0.3/4,55/5,152.3/6,127.6/
&
7,1.1/8,0.3/9,0.2
PROPERTY STREAM=54, TEMPERATURE=-30, PRESSURE=425,
PHASE=M, &
COMPOSITION(M,LBM/H)=1,7.7/2,4.3/3,0.9/4,141.1/5,293.2/ &
6,526.2/7,32.7/8,9.1/9,33.8/10,14.2/11,6.9
PROPERTY STREAM=80, TEMPERATURE=38, PRESSURE=396,
PHASE=M, &
COMPOSITION(M,LBM/H)=4,0.2/5,443.3/6,653.7/7,33.8/8,9.4/ &
9,34/10,14.2/11,6.9
PROPERTY STREAM=94, TEMPERATURE=8, PRESSURE=325,
PHASE=M, &
COMPOSITION(M,LBM/H)=4,0.2/5,443.3/6,653.7/7,0.6/8,0.1
OUTPUT FORMAT=PROPLIST, STREAMS=66, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=76, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=60,54, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=88, SPTPRINT=ON
OUTPUT FORMAT=Flujos por comp, STREAMS=66,76, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=98, SPTPRINT=ON
OUTPUT FORMAT=Flujos por comp, STREAMS=88,98, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=80, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=115, SPTPRINT=ON
OUTPUT FORMAT=Flujos por comp, STREAMS=115,122,
SPTPRINT=ON

OUTPUT FORMAT=PROPLIST, STREAMS=94, SPTPRINT=ON


OUTPUT FORMAT=PROPLIST, STREAMS=122, SPTPRINT=ON
FORMAT IDNO=Flujos por
comp,SID,NAME,PHASE,DOUBLINE,TEMP,PRESSURE, &
VFRAC,LFRAC,RATE(M),TEXT,CRATE(M),TEXT
UNIT OPERATIONS
COLUMN UID=T62, NAME=Demetanizadora
PARAMETER TRAY=43,IO=50
FEED 60,4/54,25
PRODUCT OVHD(M)=66,215.9, BTMS(M)=76, SUPERSEDE=ON
CONDENSER TYPE=PART, TEST=-147
DUTY 1,1,,CONDENSER
DUTY 2,43,,REBOILER
PSPEC PTOP=400
PRINT PROPTABLE=PART
ESTIMATE MODEL=CONVENTIONAL, RRATIO=2.1148, CTEMP=-147
SPEC ID=COL1SPEC1, RRATIO, PHASE=L, VALUE=2.1148
SPEC ID=COL1SPEC2, STREAM=66, RATE(LBM/H), COMP=4,WET,
DIVIDE, &
REFFEED, RATE(LBM/H), COMP=4,WET, VALUE=0.9989
VARY DNAME=CONDENSER,REBOILER
REBOILER TYPE=KETTLE
COLUMN UID=T82, NAME=Deetanizador
PARAMETER TRAY=67,IO=50
FEED 80,11
PRODUCT OVHD(M)=88,1097.9, BTMS(M)=98, SUPERSEDE=ON
CONDENSER TYPE=PART, TEST=18

DUTY 1,1,,CONDENSER
DUTY 2,67,,REBOILER
PSPEC PTOP=350
PRINT PROPTABLE=PART
ESTIMATE MODEL=CONVENTIONAL, RRATIO=0.6754, CTEMP=18
SPEC ID=COL2SPEC1, RRATIO, PHASE=L, VALUE=0.6754
SPEC ID=COL2SPEC2, STREAM=88, RATE(LBM/H), COMP=6,WET,
DIVIDE, &
STREAM=80, RATE(LBM/H), COMP=6,WET, VALUE=1
SPEC(CHANGE) ID=COL2SPEC3, TRAY=10, TEMPERATURE(F),
VALUE=203
VARY DNAME=CONDENSER,REBOILER
REBOILER TYPE=KETTLE
COLUMN UID=T100, NAME=Fracc Etano-Etileno
PARAMETER TRAY=100,IO
FEED 94,41
PRODUCT OVHD(M)=115,441.9, BTMS(M)=122, SUPERSEDE=ON
CONDENSER TYPE=BUBB, TEST=-18
DUTY 1,1,,CONDENSER
DUTY 2,100,,REBOILER
PSPEC PTOP=300
PRINT PROPTABLE=PART
ESTIMATE MODEL=CONVENTIONAL, RRATIO=5.62, CTEMP=-18
SPEC ID=COL3SPEC1, RRATIO, PHASE=L, VALUE=5.62
SPEC ID=COL3SPEC2, STREAM=115, RATE(LBM/H), COMP=5,WET,
DIVIDE, &
STREAM=94, RATE(LBM/H), COMP=5,WET, VALUE=0.9959
VARY DNAME=CONDENSER,REBOILER

REBOILER TYPE=KETTLE
END

Ppr78

$ Generated by PRO/II Keyword Generation System <version 9.2.1>


$ Generated on: Thu Oct 22 12:50:13 2015
TITLE PROJECT=TESIS, PROBLEM=Val Shortcut, USER=MS and LE, SITE=HOME
DESC Validacin del sistema termodinamico para las torres de destilacion
DESC del proceso de purificacin y recobro de etileno.
DESC Sistema Termodinamico: Predictive Peng-Robinson 78
DESC Autores: Luis Embus
DESC

Michael Sutherland

DESC
DIMENSION ENGLISH, STDTEMP=60.0008, STDPRES=14.6959
SEQUENCE SIMSCI
CALCULATION TVPBASIS=100, RVPBASIS=APIN
COMPONENT DATA
LIBID 1,H2/2,N2, BANK=SIMSCI,PROCESS
LIBID 3,CO/4,METHANE/5,ETHYLENE/6,ETHANE/7,PROPENE/8,PROPANE/ &
9,BUTANE/10,PENTANE/11,HEXANE, BANK=SIMSCI
ASSAY FIT=ALTERNATE, CONVERSION=API94, CURVEFIT=CURRENT, &
KVRECONCILE=TAILS, FORMATION=CURRENT
THERMODYNAMIC DATA

METHOD SYSTEM=PPR78, TRANSPORT=PETR, SET=PPR7801, DEFAULT


STREAM DATA
PROPERTY STREAM=60, TEMPERATURE=-80, PRESSURE=425, PHASE=M, &
COMPOSITION(M,LBM/H)=1,2.6/2,1.7/3,0.3/4,55/5,152.3/6,127.6/ &
7,1.1/8,0.3/9,0.2
PROPERTY STREAM=54, TEMPERATURE=-30, PRESSURE=425, PHASE=M, &
COMPOSITION(M,LBM/H)=1,7.7/2,4.3/3,0.9/4,141.1/5,293.2/ &
6,526.2/7,32.7/8,9.1/9,33.8/10,14.2/11,6.9
PROPERTY STREAM=80, TEMPERATURE=38, PRESSURE=396, PHASE=M, &
COMPOSITION(M,LBM/H)=4,0.2/5,443.3/6,653.7/7,33.8/8,9.4/ &
9,34/10,14.2/11,6.9
PROPERTY STREAM=94, TEMPERATURE=8, PRESSURE=325, PHASE=M, &
COMPOSITION(M,LBM/H)=4,0.2/5,443.3/6,653.7/7,0.6/8,0.1
OUTPUT FORMAT=PROPLIST, STREAMS=66, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=54,60, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=76, SPTPRINT=ON
OUTPUT FORMAT=Flujos por comp, STREAMS=66,76, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=80, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=88, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=98, SPTPRINT=ON
OUTPUT FORMAT=Flujos por comp, STREAMS=88,98, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=115, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=122, SPTPRINT=ON
OUTPUT FORMAT=PROPLIST, STREAMS=94, SPTPRINT=ON
OUTPUT FORMAT=Flujos por comp, STREAMS=115,122, SPTPRINT=ON
FORMAT IDNO=Flujos por comp,SID,NAME,PHASE,DOUBLINE,TEMP,PRESSURE,
&

VFRAC,LFRAC,RATE(M),TEXT,CRATE(M),TEXT
UNIT OPERATIONS
COLUMN UID=T62, NAME=Demetanizadora
PARAMETER TRAY=37,IO
FEED 60,4/54,13
PRODUCT OVHD(M)=66,215.9, BTMS(M)=76, SUPERSEDE=ON
CONDENSER TYPE=PART, TEST=-147
DUTY 1,1,,CONDENSER
DUTY 2,37,,REBOILER
PSPEC PTOP=400
PRINT PROPTABLE=PART
ESTIMATE MODEL=CONVENTIONAL, RRATIO=2.1148, CTEMP=-147
SPEC ID=COL1SPEC1, RRATIO, PHASE=L, VALUE=2.1148
SPEC ID=COL1SPEC2, STREAM=66, RATE(LBM/H), COMP=4,WET, DIVIDE, &
REFFEED, RATE(LBM/H), COMP=4,WET, VALUE=0.99
VARY DNAME=CONDENSER,REBOILER
REBOILER TYPE=KETTLE
COLUMN UID=T82, NAME=Deetanizador
PARAMETER TRAY=47,IO
FEED 80,14
PRODUCT OVHD(M)=88,1097.9, BTMS(M)=98, SUPERSEDE=ON
CONDENSER TYPE=PART, TEST=18
DUTY 1,1,,CONDENSER
DUTY 2,47,,REBOILER
PSPEC PTOP=350
PRINT PROPTABLE=PART

ESTIMATE MODEL=CONVENTIONAL, RRATIO=0.6754, CTEMP=18


SPEC ID=COL2SPEC1, RRATIO, PHASE=L, VALUE=0.6754
SPEC(CHANGE) ID=COL2SPEC2, STREAM=88, RATE(LBM/H), COMP=6,WET,
&
DIVIDE, STREAM=80, RATE(LBM/H), COMP=6,WET, VALUE=1
SPEC ID=COL2SPEC3, TRAY=47, TEMPERATURE(F), VALUE=203
VARY DNAME=CONDENSER,REBOILER
REBOILER TYPE=KETTLE
COLUMN UID=T100, NAME=Frac. Etano-Etileno
PARAMETER TRAY=70,IO
FEED 94,31
PRODUCT OVHD(M)=115,441.9, BTMS(M)=122, SUPERSEDE=ON
CONDENSER TYPE=BUBB, TEST=-18
DUTY 1,1,,CONDENSER
DUTY 2,70,,REBOILER
PSPEC PTOP=300
PRINT PROPTABLE=PART
ESTIMATE MODEL=CONVENTIONAL, RRATIO=5.62, CTEMP=-18
SPEC ID=COL3SPEC1, RRATIO, PHASE=L, VALUE=5.62
SPEC ID=COL3SPEC2, STREAM=115, RATE(LBM/H), COMP=5,WET, DIVIDE,
&
STREAM=94, RATE(LBM/H), COMP=5,WET, VALUE=0.9959
VARY DNAME=CONDENSER,REBOILER
REBOILER TYPE=KETTLE
END