You are on page 1of 14

TG turbine

T-G SPECIFICATIONS
O/P
NO OF PHASES
NO OF POLES
VOLTAGE
CURRENT
FREQUENCY
SPEED
P.F
RATING
EXCITATION VOLT
FIELD CURRENT
CLASS OF INSULATION:

225OO KVA
3
4
11 KV
1181
50 HZ
1500 RPM
0.9
CONT
244 V
452
ARMATURE: F
FIELD: F

GVC TG
To condenser

0.2
k/c2

-0.2
k/c2
150 c

Vapor in

1.1
k/c2
Gland sealing
steam
25
k/c2

To Condenser

EJECTOR TG
FROM CONDENSER

TO PDM

START UP
IJECTOR

TO CONDENSER

condensate
vapor
46

steam
ejector

TG GOVERNER
Make

GE MDT 80

TYPE

ELECTRONIC SPEED CONTROL

Speed regulation

0 to 5 % droop

Speed control range

0 to 105 % of rated

Speed setting accuracy

+- 0.1 % of rated

Pressure regulation

0 to 10 % of droop

Pressure control range

0.85 to 1.15 % of rated

Pressure setting accuracy +- 2 % of rated


Hydraulic pr

200 +- 5 psig

Bearing pr Turbine

21 +- 2 psig

All setting to be made at

Oil temp to bearing 110 to 120 of

TG ALARMS AND TRIPPING


Sr
no

Parameter

LUB OIL PR LOW

AA1

1 K/C2

LUB OIL PR LOW

AA2

0.8 K/C2

CONTRO OIL PR LOW ALARM

AA3

10 K/C2

ACROSS FILTER DP LOW

AA4

1 K/C2

LUB OIL TANK LEVEL LOW

AA5

13 INCH
1 INCH

LUB OIL TEMP HIGH

AA6

42

59

RTD FAULTY OR SUPPLY FAILS

AA7

BEARING OR WINDING TEMP HIGH

AA8

51/65

75/95

BEARING OR WINDING TEMP VERY


HIGH

AA9

80

130

10

RTD FAULTY OR FAIL

AA10

11

BEARING TEMP HIGH

AA11

120

12

BEARING TEMP VERY HIGH

AA12

130

13

TRANSDUCER FAULTY OR SUPPLY


FAILS

AA13

14

AXIAL DISPLACEMENT HIGH

AA14

15/18 MILS

15

AXIAL DISPLACEMENT IS VERY


HIGH TURBINE TRIPS

AA15

28 MILS

16

TG SET VIBRATION HIGH

AA16

Alarm3.6/3.4/1.4/2.4/3.
6/4 mils

20 MILS

TG ALARMS AND TRIPPING


Sr
no

Parameter

17

TG SET VIBRATION VERY HIGH


TURBINE TRIPS

AA17

18

2 SPEED PICK FAIL TURBINE TRIPS

AA18

19

OVER SPEED TURBINE TRIPS

AA19

20

GCPS 1 FAILS MAINTENANCE


REQUIRED ALARM

AA20

21

SPEED PICK UP-1 FAILS


MAINTENANCE REQUIRED ALARM

AA21

22

TURBINE RUNNING BELOW 4 RPM


TO START THE BARRING GEAR

AA22

23

ABOVE 110% SP TURBINE RUNNING


HSS

AA23

24

LOAD CONTROL

AA24

25

EXHAUST PRESSURE VERY HIGH


TURBINE TRIP-

AA25

0.55KG/CM2 OR
40.85 CM HG
(VACUUM)

26

INLET STEAM TEMPERATURE VERY


LOW TURBINE TRIP

AA26

365*C

27

TURBINE INLET CLOSED BELOW


COOLING LIMIT

AA27

28

TURBINE SIXTH STAGE


TEMPERATURE HIGH
ALARM/TIPPING

AA28

29

TURBINE TRIP DUE TO ELECTRICAL


FAULT

AA29

4.8/4.8/2.6/4.6/4.
5/4.8 mils

260/370 *C

TG ALARMS AND TRIPPING


Sr no

Parameter

30

EXHAUST PRESSURE HIGH

AA30

31

MANUAL TRIP ALARM

AA31

32

AA32

33

INLET STEAM TEMP LOW

AA33

430

34

1ST EXTRACTION PR HIGH

AA34

10 K/C2

35

1ST EXTRACTION PR VERY HIGH

AA35

11.5 K/C2

36

II ND EXTRACTION PR HIGH

AA36

4.6 K/C2

37

II ND EXTRACTION PR VERY HIGH

AA37

5.0 K/C2

38

EXHAUST TEMP ALARM

AA38

80 0C

39

INLET STEAM PR LOW ALARM

AA39

70 K/C2

40

MAIN STEAM PR LOW ALARM

AA 40

74 K/C2

41

Inlet Steam Temperature Very Low

AA41

365 OC

42

Ist Ext. Press. Low after NRV

AA42

43

IInd Ext. Press. Low after NRV

AA43

44

AA44

45

Exhaust Hood Temperature High

AA45

46

86G Or HT Panel Breaker Trip


(Electrical Fault)

AA46

47

SLIT Or HT Panel breaker Trip


Process Fault

AA47

80 *C

SV 10.7 K/C2

SV 4.7

TG ALARMS AND TRIPPING


Sr no

Parameter

48

Hot Air Temperature High

AA 48

(39/45 *C)
*C

49

Hot Well Level Low

AA 49

70% 40%

50

Hot Well Level Very Low

AA 50

35%

51

Hot Well Level High

AA 51

52

75/80

AA 52

53

CW Inlet Pressure Low

AA 53

1.5 Kg/cm2 0.9 Kg/cm2

54

Ist Extraction Temperature High(After


DSS)250 *C

AA 54

250 *C

55

IInd Extraction Temperature High

AA 55

150 *C

56

Ist Ext. Press. High Before NRV

AA 56

57

IInd Ext. Press. High Before NRV

AA 57

58

Ist Ext. Steam Temperature Low

AA 58

59

IInd Ext. Steam Temperature Low

AA 59

60

SLIT 502 (Turbine Trip)

AA 60

Sr
no

OV

LAOD (MW)

8.7

SPEED (RPM)

8000

STEAM PRESSURE(K/C2)
MAIN ST PRESSURE

85

IST EXTR PRESSRE

10

II ND EXTR

EXHAUST STEAM

1/09

STEAM TEMPERATURES (OC)


MAIN STEAM

470

IST EXTR

270

II ND EXTR

194

EXHAUST STEAM

40

LUBE OIL PRESSURE (K/C2)

1.55/1.
35

CONTROL OIL PRESSURE


(K/C2)

14/12.
8

FLOW (TON/HR)
MAIN STEAM

85

IST EXTR

28

II ND EXTR

35

CONDENSER

Unit

Sr
no

ALARM

Parameter

OV

BEARINGTEMPERATURES (OC)

TG OPERATING PARAMETERS

Parameter

TURBINE JOURNEL
HP BEARING

80/71(9)

LP BEARING

82/79

TURBINE THURST + VE

70/67
68/66(8)

TURBINE THURST -VE

55/53
51/54

GEAR BOX
PINION TURBINE END

84/87

PINION ALTERNATOR END

79/81

GEAR WHEEL TURBINE END

60/61

GEAR WHEEL ALTERNATOR END

70/67(3)

GENERATOR TURBINE END

50/51

GENERATOR ALTERNATOR END

50/49

ROTOR AXIAL POSITION (MILLS)

17/19

VIBRATIONS( MILS) VER / HZT


TURBINE HP BEARING

1.2/0.9

TURBINE LP BEARING

2.2/2.5

GEAR PINION TURBINE END

4.5/4.0

GEAR PINION ALT END

4/4

GENERATOR

2.5/3.6
2.2/2.1

Alar
m

Trip

Sr
no

OV

CONDENSER LEVEL

70 5

GEAR BOX OIL TEMP (0C)

70

VACUUM

70

IST EXTR DESUP TEMP.(OC)

257

CONDENSATE PUMP PR(K/C2)

4.25

COND. PUMP LOAD (AMPS)

22

CW PR COND. INLET (K/C2)

1.2

CW PR COND. OUTLET (K/C2


CW TEMP IN TO LUB OIL
COOLER

22

CW TEMP OUT TO LUB OIL


COOLER

30

MOP DISCH OIL PR

0.25/1
3.7

BEARING OIL DRAIN TEMP

61/63

LUB OIL COOLER OUTLET

40

COND CW OUTLET TEMP

25

TURBINE 6 TH STAGE TEMP

215

I ST STAGE SHELL PR

46

GLAND STEAM PRESSURE

0.45

VANE 1

1.5

VANE 2

13/8

VANE 3

3/4

U
nit

Sr
no

ALARM

TG OPERATING PARAMETERS

Parameter
(TEMP OC AND PRESSUREK/C2)

Parameter

OV

PRIMARY EJET STEAM PR

40

SECONDARY EJECT. STEAM PR

40

PRIMARY EJECT VACUUM


(MMHG)

700

SEC.EJECT. VACUUM(MMHG)

570

COND OUTLET TEMP

42

COND VACUUM AT GVC MMHG

0.15

COND TEMP AT GVC

150

Alar
m

Trip

Sr
no

Parameter
(TEMP OC AND PRESSUREK/C2)

Sr
no
1.0

Very low lub oil trip switch

0.8

Low control oil pressure alarm

10

1 st ext steam pr high alarm

10

2nd ext steam pressure high alarm

4.6

1st ext pr very high trip switch

11.5

2nd ext steam pressure very high trip


switch

Lub oil pr drop across the filter


alarm

5 psi

Barring gear interlock with low lub


oil pressure

0.8

Exhaust hood very low vacuum trip

0.55

AOP auto start

11

Gear oil pump start indication

10

EOP Steam driven start indication

10

AC driven oil pump start indication

10

EOP auto start

10

Lub oil temperature alarm

59

Exh hood high temperature alarm

SAFETY RELIEF VALVE


SETTINGS

TG OPERATING ALRMS

Low lub oil pr alarm

Parameter

1ST EXTRACTION SAFETY V/V

10.7

2 NOS

2ND EXT SAFETY V/V

3.7

2 NOS

LUB OIL SAFETY V/V

2.4

CONTROL OIL SAFETY V/V

15.5 &

EXH HOOD SENTINEL RELIEF

5 PSI

STEAM SEAL LINE RELIEF

15 PSI

CONDENSER SAFERTY V/V

5 PSI

JOURNEL BEARING TEMP ALARM

250 OF

121 OC

JOURNEL BEARING TEMP HIGH


TRIP

275 OF

135 OC

TRUST BEARING TEMP HIGH

275 OF

135 OC

THRUST BEARING TEMP HIGH


TRIP

300 OF

148 OC

VIBRATION PROBES

ALARM
3.5 MILS

TRIP 5.0
MILS

ROTOR POSTION PROBE

AL -10
MILLS

TRIP 20
MILS

CRITICAL SPEED 1ST

1900

CRITICAL SPEED 2ND

4800

ELECT GOVER./ TRIP

8606

MECH TRIPIING

8890

17

TG LUB OIL SYSTEM

HP & THRUST

LP BEARING

GEAR BOX

ALT T END

ALT A END

1.4 LUB

MOP

V 1,2,3

14 CONTROL
EOP
LOC

LOC

LOC

AOP
F

EOP (Emergency oil pump)


(Steam Driven)
Make
:Triveni
Mather and Platt
M3 /HR

Head (m)
RPM
Inlet steam pr.
Inlet st. Temp.
Exh. Pr.(kg/cm2
:03
RPM
KW
Over speed trip
Exh. Relief (kg/c2)
Ist critical speed

:78
:206
:2975
:46 42
:410 405)
:2930
:75
:3345
:3.5
:7400

AOP (Auxiliary oil pump)


(Electric Driven)
Motor KW
:75
Rpm
:2960
Current
:124 amps

Condensate Extraction pump


Make
Type
M3 /HR
HEAD (M)
RPM

:KSB
:CPK 60 M
:50
:50
:1440

Motor
KW(HP)
RPM
AMPS

:15 (20)
:1455
:29

LUBE OIL FILTER


Ful flow commercial filters
Model :hsf 19-3-4
Max design
operating pressure:
300 psi at 200 oF

You might also like