You are on page 1of 3

12/14/2015

Typhon Group: EASI - Evaluation & Survey Instrument

Responses About You - Summary - "Brachytherapy Planning Competency"


Print
TOTAL RESPONSES: 1
Select the brachytherapy planning competency from the drop down menu below:
Response Response
Percent
Total

(Choice - One Answer Drop Down)


Intracavitary

0.0%

Interstitial

100.0%

0.0%

0.0%

0.0%

0.0%

0.0%

0.0%

0.0%

0.0%

0.0%

0.0%

0.0%

0.0%

0.0%

0.0%

0.0%

0.0%

0.0%

0.0%

Total Respondents:

Skipped this question:

Please assign each task a score of Satisfactory or Unsatisfactory.

Unsatisfactory in any essential task constitutes competency failure.


The student will repeat the competency at a later date.
(Rating Scale - Matrix)
Statistical Mode in BOLD

1
Unsatisfactory

2
Satisfactory

0
N/A

Additional
Comment

Mean Percentage
[0-2]
Score

Discusses the plan


prescription with the
physician.

0.0% (0)

100.0% (1)

0.0% (0)

2.00

100.0%

Loads the patient imaging


studies into the planning
computer.

0.0% (0)

100.0% (1)

0.0% (0)

2.00

100.0%

Contours the appropriate


https://www.typhongroup.net/eval/analyze/studentsummary.asp?survey=14196&facility=9094&msgtext=

1/3

12/14/2015

Typhon Group: EASI - Evaluation & Survey Instrument

anatomy on the image data


set.

0.0% (0)

100.0% (1)

0.0% (0)

2.00

100.0%

Identifies appropriate dose


points on the image data
set.

0.0% (0)

100.0% (1)

0.0% (0)

2.00

100.0%

Successfully identifies
source positions.

0.0% (0)

100.0% (1)

0.0% (0)

2.00

100.0%

Identifies available isotope


and activity for date and
time of treatment.

0.0% (0)

100.0% (1)

0.0% (0)

2.00

100.0%

Correctly generates plan


using appropriate isotope
and activity to achieve
treatment objective.

0.0% (0)

100.0% (1)

0.0% (0)

2.00

100.0%

Accurately generates
DVH/Dose point summary
for implant.

0.0% (0)

100.0% (1)

0.0% (0)

2.00

100.0%

Communicates effectively
with physician for plan
review and makes changes
as requested.

0.0% (0)

100.0% (1)

0.0% (0)

2.00

100.0%

Exports/Prints appropriate
plan data.

0.0% (0)

100.0% (1)

0.0% (0)

2.00

100.0%

Performs hand verification


calculations for dwell time.

0.0% (0)

0.0% (0)

100.0% (1)

0.00

0.0%

Assembles necessary
equipment for source
loading.

0.0% (0)

0.0% (0)

100.0% (1)

0.00

0.0%

Makes appropriate entries in


source log and fills out
necessary paperwork for
appropriate room posting.

0.0% (0)

0.0% (0)

100.0% (1)

0.00

0.0%

Prepares sources for


transport and loading.

0.0% (0)

0.0% (0)

100.0% (1)

0.00

0.0%

Observes source insertion.

0.0% (0)

0.0% (0)

100.0% (1)

0.00

0.0%

Performs appropriate
patient room surveys.

0.0% (0)

0.0% (0)

100.0% (1)

0.00

0.0%

Uses appropriate radiation


measuring devices for
brachytherapy procedures
and source inventory.

0.0% (0)

0.0% (0)

100.0% (1)

0.00

0.0%

Uses time, distance and


shielding principles during
brachytherapy procedures.

0.0% (0)

0.0% (0)

100.0% (1)

0.00

0.0%

OVERALL COUNTS/MEANS:

10

1.11

55.6%

Total Respondents:

Skipped this question:

Overall rating:
(Rating Scale - One Answer

https://www.typhongroup.net/eval/analyze/studentsummary.asp?survey=14196&facility=9094&msgtext=

If applicable, please

Mean Percentage
2/3

12/14/2015

Typhon Group: EASI - Evaluation & Survey Instrument

Horizontal)
Statistical Mode in BOLD

Fail

Pass

0.0% (0)

100.0% (1)

specifiy reason for


failure

[1-2]

Score

2.00

100.0%

Total Respondents:

Skipped this question:

Additional Comments:
(Open Ended - Comments Box)
Total Respondents: 1
Skipped this question: 0
Mean percentage score for all rating scale questions: 77.8%
(Each main question equally weighted)
Responses as of 12/14/2015 2:40:59 PM CT

https://www.typhongroup.net/eval/analyze/studentsummary.asp?survey=14196&facility=9094&msgtext=

3/3

You might also like