You are on page 1of 55

Project Name: FTTX-GPON

Project Number: 2052501

District
Riyadh

Site Name
QAIRAWAN/HUT
EEN

City
Riyadh

Site Number
111-00-000

CLLI Code
HTYNRD00

Job Number
J-11100000-00047/J11100000-00048

Mop Number: M-FTE-00001


Mop Type: FTTH
Date of MoP: 8/18/2009
Revision Status:
Vendor : FUJITSU TELECOMMUNICATIONS EUROPE LTD.
Engineer ID:
Engineer Name: Martin Betts\M. Calvelo\D. Lopez
SoW No: S-0030374
X Location : 4636'32.4"
Y Location : 2446'27.13"
Generated using MoPGenTools (R-1.5.5.8)

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Scope Of Work
Page 1 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

Document Change Record

Rev.
1.0

Project Name
Mop Type
Eng. Name
Site Name

Date
10/19/2009

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

Description
Initial

2052501
M-FTE-00001

Scope Of Work
Page 2 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

By
Martin Betts\M.
Calvelo\D. Lopez

Table Of Contents

INTRODUCTION ...........................................................................................5

1.1

Scope Of Work ............................................................................................................................... 5

1.2

Equipment Description.................................................................................................................. 6

DETAILED DESIGN ......................................................................................8

2.1

List of Materials (111-00-000)............................................................................................................. 8

2.2
2.3

Typical Network Diagram................................................................................................................ 10


Typical End User Delivery Diagram .............................................................................................. 11

2.4
Configuration and Detailed View (111-00-000) ......................................................................... 12
2.4.1
CO : 111-00-000 ( 00 ) .............................................................................................................. 12
2.4.2
CO : 111-00-000 ( 00 ) .............................................................................................................. 12
2.4.3
OLT Rack Face Layout ............................................................................................................. 13
2.4.4
OLT Rack Equipment List ........................................................................................................ 13
2.4.5
OLT Sub Rack Layout .............................................................................................................. 14
2.4.6
OLT Sub Rack Equipment List ................................................................................................. 15
2.4.7
OOB Management Switch (Temporary) ................................................................................... 16
2.4.8
OOB Management Equipment List (Temporary)...................................................................... 17
2.4.9
FDF Rack Face Layout.............................................................................................................. 17
2.4.10 FDF Rack Equipment List......................................................................................................... 18

Physical And Logical Addressing Tables ................................................................................... 19


2.5
2.5.1
111-00-000 : MO-AXS1800-OLT (GPON) .............................................................................. 19
2.5.2
111-00-000 : ATC-PLT-SPLT-8x1:2 (OUT) ............................................................................ 22

2.6

Network Connectivity Diagram .................................................................................................. 29

Master Sheet(Attachment) .......................................................................................................... 31


2.7
2.7.1
OOB Management Table (Temporary) ..................................................................................... 32
2.7
ICMS ............................................................................................................................................ 33
2.7.1
ICMS Diagram(Attachment) .........................................................................................................
2.7.2
ICMS Table(Attachment)..............................................................................................................

2.9
Power Connectivity Drawings..................................................................................................... 34
2.9.1
DCDP Diagram ......................................................................................................................... 35
2.9.2
DCDP Location ........................................................................................................................ 35
2.9.3
DCDP Connectivity Table ........................................................................................................ 36
2.9.4
PDU Layout .............................................................................................................................. 37
2.9.5
PDU Equipment List/Connection Table ................................................................................... 38

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Scope Of Work
Page 3 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

APPROVALS ..............................................................................................39

3.1.1

Floor Plan....................................................................................................................................... 39

3.1.2

Extracted Floor Plan....................................................................................................................... 40

3.1.3

Floor Space Approval .................................................................................................................... 41

3.1.4

Power Approval ............................................................................................................................. 42

3.1.5

Permit to Work............................................................................................................................... 43

ANNEX ........................................................................................................44

4.1
Location Maps .............................................................................................................................. 44
4.1.1
Location Map for Site: 111-00-000 (Zoom 1)........................................................................... 44
4.1.2
Location Map for Site: 111-00-000 (Zoom 2)........................................................................... 45
4.1.3
Location Map for Site: 111-00-000 (Zoom 3)........................................................................... 46

Project Name
Mop Type
Eng. Name
Site Name

GLOSSARY.................................................................................................47

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Scope Of Work
Page 4 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

1 INTRODUCTION
1.1

Project Name
Mop Type
Eng. Name
Site Name

Scope Of Work

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Scope Of Work
Page 5 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

Network Design

Requirements For
OSP FTTH

Fujitsu Telecommunication Europe Ltd


S-0030374
Revision No:

Marzook N Al Otaibi
Date Printed: 29/08/2009

Network Design

I. Main
1. General
By assuming

All dwelling units (Residential & Commercial) unit will be fibered

The type of ONT to serve each unit is single family unit (SFU) or single business unit (SBU).

1:2 splitters will be installed in the frame distribution frame (FDF) in the CO area and 1:32 splitters in FDT
located in OSP. Each 1:32 splitter will be distributed through secondary network.

Date Printed: 29/08/2009

Sow No: S-0030374

Rev. #: 2

Page 2 of 8

Network Design

2. General Requirements

All equipment must by have type approval from STC.

All MOP documentation must be depending on RFP.

Optical splitters should be preconnectorized with LC/APC connectors for mounting in pre-assembled
splitters cabinets.

Maximum distance (Reach) between OLT and ONT is 20Km.

Single fiber (Single Mode fiber G657) is used to connect the OLT located in the Central Office (CO), and
the ONTs located at the customer premises.
The routing and location of feeder route should consider the overall link budget which is 28dB, (Class B+), and
the position/location to ensure an easy access for the splitter cabinet.
Central Office (OLT) Requirements
The OLT PON port offers 2.5 Gbps bandwidth in down link and 1.25 Gbps in uplink.
GPON Bandwidth (DL)
Split Ratio Average Bandwidth (DL) / user
2.5 Gbps
1:64
39 Mbps

Date Printed: 29/08/2009

Sow No: S-0030374

Rev. #: 2

Page 3 of 8

Network Design

3. Scope Description
This SOW To project (FTTH) solution in (Hutten 111-00-000 ) to provide 1 OLT with High Speed Internet
Access (HSIA), and triple play services (Voice, Video, Data) using the FTTH GPON architecture.

Date Printed: 29/08/2009

Sow No: S-0030374

Rev. #: 2

Page 4 of 8

Network Design

II. Summary of Scope of Work


The following table summarizes the equipment/services to be installed on each site and ring, if applicable, for
this Scope of Work.

Ring

Site Name

Equipment /Model Name

111-00-000

OLT

Qairawan/Huteen

AXS 1800

111-00-000

Splitter ODF

Qairawan/Huteen

Splitter ODF

III. CUL Requirements

Date Printed: 29/08/2009

Sow No: S-0030374

Rev. #: 2

Page 5 of 8

Network Design

Quantity Table For

Installation

Equipment Model/Services :

OLT

Ring No :
Site Number :

111-00-000

Qairawan/Huteen

Unit Code

Unit Description

Qty

FS-OLT-202-SAd

OLT Services :Installation , Commissioning and Integration AXS 1800 Chassis

1.00

GPON180a

OLT:Four Port 2.4/1.2 Gbps G.984 interface

14.00

FS-OLT-203-SAd

OLT Services :Installation of PON Interface to Splitter and Test

56.00

FS-OLT-201-SAd

OLT Services :Site Survey - Installation Pack (Site Specific As Built Definitions, Method &
Risk Assessments)

1.00

GPON195b

OLT Software:AXS1800 system software R6.1 on CDROM

1.00

GPON190b

OLT Software:AXS1800 R6.1 RTU Fee. One required per AXS1800 or AXS2200.

1.00

GPON160a

OLT:10km XFP (10GbE) standard pluggable optics module, Industrial Temperature, RoHS
compliant. For use with the ASW200D pack.

2.00

GPON100a

OLT:Fujitsu ETSI ,2200x600x600

1.00

GPON120a

OLT:AXS1800 Chassis (19" rack) with fan assembly, documentation CD & Installation and
Maintenance Guide

1.00

GPON130a

OLT:Mounting Bracket for AXS1800 chassis to comply with ETSI standard racks

1.00

GPON140a

OLT:System Controller for the AXS1800 & AXS2200; temperature-hardened

2.00

GPON150a

OLT:200 Gbps Switch and processor with integrated six 1GbE & one 10GbE uplink ports;
SFP and XFP optical modules not included

2.00

FS-OLT-204-SAp

OLT Services :Project Management per Site

1.00

Remarks :

Equipment Model/Services :

Splitter ODF

Ring No :

Date Printed: 29/08/2009

Sow No: S-0030374

Rev. #: 2

Page 6 of 8

Network Design

Site Number :

111-00-000

Qairawan/Huteen

Unit Code

Unit Description

Qty

GPON320a

Splitter ODF:Fibre Distribution Rack including Fibre Management

OSP833a

OSP :Patch Cord , LC/APC - LC/APC (3m)

112.00

OSP845a

OSP :Patch Cord , SC/APC - LC/APC (5m)

56.00

GPON210a

Splitter ODF :Splitter shelf splitter panels 8 x 1by2 splitters pre connectorised in each shelf

7.00

FS-SPL-140-SAa

Splitter ODF: Overhead Ironwork Supply and Install

2.00

GPON372a

Splitter ODF: 72 Port (inc pigtails)

4.00

FS-SPL-150-SAd

Splitter ODF: FDF Installation

1.00

Remarks :

1.00

Design to be for 8 ODFs. Remaining 4 ODFs from CUL to be added by OSP team.

IV. PRN's And Customers

The following table indicates the Planning Reference Numbers (PRN) and the STC internal customers that are
served by this SoW.
This table is for STC internal use only.
Site No./Site Name

PRN

Ring No.

Customer

111-00-000
Qairawan/Huteen

Interface

Assigned
Capacity
0.00

V. Scope of Work Attachments

List of attachments.

Date Printed: 29/08/2009

Sow No: S-0030374

Rev. #: 2

Page 7 of 8

Network Design

End of Document

Date Printed: 29/08/2009

Sow No: S-0030374

Rev. #: 2

Page 8 of 8

1.2

Equipment Description

AXS 1800 OLT


The AXS 1800 OLT is an ETSI and RoHS-compliant, rack-mount chassis GPON Optical Line Terminal that can
be mounted in any of three standard rack widths: ETSI, EIA 19", and EIA 23".
The chassis provides an 18-slot backplane for plug-in cards. The 18 slots consist of:

14 Application Unit card slots: for AGPOND cards


2 Switch card slots: for ASW200D cards
2 System Controller card slots: for ASYSC cards

Network interface ports are supported by the Application Unit and Switch cards. The plug-in cards
themselves provide the connectors for the optical ports: 1- or 10-Gigabit Ethernet, and GPON. Operations
interfaces are supported by the System Controller card. The connectors (for all but the CLI console) are on
the chassis rear panel: RJ-45 Ethernet for management systems, and DB37 for miscellaneous discrete inputs
and CO audible/visual alarm outputs.

AGPOND
The AGPOND card is a four-port 2.4/1.2 Gbps G.984 single-fiber GPON interface for the AXS1800. It is an
Application Unit card supported in slots AU-1 through AU-14 of the AXS1800.
The AGPOND card supports four, asymmetric 2.4 Gbps downstream / 1.2 Gbps upstream, single-fiber PON
interfaces. It has four simplex SC connectors.
The AGPOND card works with standards-compliant GPON ONTs such as the ONT1400GTI. It supports up to
64 ONTs per PON, 256 ONTs per card. PON ranges up to 20 km are supported.
Two of the three wavelengths in the PON are used by the OLT and supported by the AGPOND card:
1490nm downstream from OLT to ONT, 1310 nm upstream from ONT to OLT. The third, video overlay
wavelength does not involve the OLT: 1550 nm downstream to ONT.

ASW200D
The ASW200D Switch card provides a 200 Gbps Ethernet switch and processor with six 1-Gigabit Ethernet
interface ports or one 10-Gigabit Ethernet interface port for the AXS1800.
The chassis can be provisioned to use either the 1-Gigabit Ethernet ports (up to six on each card) or the 10Gigabit Ethernet ports (one on each card). The two types of ports cannot both be used simultaneously. For
each of the six 1-Gigabit Ethernet ports, hot-pluggable SFP (Small Form-factor Pluggable) optics support
either a 10 km, 40 km, or 80 km optical reach with a duplex LC connector. For the one 10-Gigabit Ethernet
port, hot-pluggable XFP (10 Gigabit Small Form-factor Pluggable) optics support a 10 km optical reach with
a duplex LC connector. The SFP or XFP optics must be ordered separately.
The ASW200D Switch card provides protection (when equipped in both slots SW-A and SW-B) for the switch
fabric and the system timing synchronization and distribution. The Switch card supports independent,
unprotected service connections on the 1- or 10-Gigabit Ethernet ports in each slot. It also supports Link
Aggregation Groups to increase service availability of the Gigabit Ethernet ports in the event of link failures.

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Equipment Description
Page 6 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

ASYSA or ASYSC
The ASYSC System Controller card for the AXS1800 provides the system control processor, the non-volatile
memory (for the OLT and ONT system release software, the configuration
database, and the system logs), the operations interfaces, and the alarm summary LEDs. The ASYSC card is
RoHS compliant and so is required for RoHS-compliant AXS1800 applications.
Protection is provided for these functions when ASYSC cards are equipped in both slots SYS-A and SYS-B.
The operations interfaces are: RS-232 DB9 female connector on front panel for CLI console; 10/100BASET
Ethernet RJ-45 connector on chassis rear panel for management systems; DB37 female connector on
chassis rear panel for miscellaneous discrete inputs and CO audible/visual alarm outputs; alarm cutoff and
reset buttons.

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Equipment Description
Page 7 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

2 DETAILED DESIGN
2.1

Equipment Model/Services
Site Number

List of Materials (111-00-000)

OLT
111-00-000

Unit Code

Unit Description

Qty

FS-OLT-201-SAd

OLT Services :Site Survey - Installation Pack (Site Specific As Built Definitions, Method &

1.00

Risk Assessments)
GPON160a

OLT:10km XFP (10GbE) standard pluggable optics module, Industrial Temperature, RoHS

2.00

GPON120a

OLT:AXS1800 Chassis (19" rack) with fan assembly, documentation CD & Installation and

1.00

Maintenance Guide
GPON150a

OLT:200 Gbps Switch and processor with integrated six 1GbE & one 10GbE uplink ports;

2.00

SFP and XFP optical modules not included


FS-OLT-202-SAd

OLT Services :Installation , Commissioning and Integration AXS 1800 Chassis

1.00

GPON180a

OLT:Four Port 2.4/1.2 Gbps G.984 interface

14.00

FS-OLT-203-SAd

OLT Services :Installation of PON Interface to Splitter and Test

56.00

GPON195b

OLT Software:AXS1800 system software R6.1 on CDROM

1.00

GPON190b

OLT Software:AXS1800 R6.1 RTU Fee. One required per AXS1800 or AXS2200.

1.00

compliant. For use with the ASW200D pack.


GPON100a

OLT:Fujitsu ETSI ,2200x600x600

1.00

GPON130a

OLT:Mounting Bracket for AXS1800 chassis to comply with ETSI standard racks

1.00

GPON140a

OLT:System Controller for the AXS1800 & AXS2200; temperature-hardened

2.00

FS-OLT-204-SAp

OLT Services :Project Management per Site

1.00

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

List of Materials (111-00-000)


Page 8 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

Equipment Model/Services
Site Number

OLT
111-00-000

Unit Code

Unit Description

Qty

GPON320a

Splitter ODF:Fibre Distribution Rack including Fibre Management

OSP833a

OSP :Patch Cord , LC/APC - LC/APC (3m)

112.00

OSP845a

OSP :Patch Cord , SC/APC - LC/APC (5m)

56.00

GPON210a

Splitter ODF :Splitter shelf splitter panels 8 x 1by2 splitters pre connectorised in each shelf

7.00

FS-SPL-140-SAa

Splitter ODF: Overhead Ironwork Supply and Install

2.00

GPON372a

Splitter ODF: 72 Port (inc pigtails)

8.00

FS-SPL-150-SAd

Splitter ODF: FDF Installation

1.00

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

List of Materials (111-00-000)


Page 9 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

1.00

2.2

Typical Network Diagram

Voice, IPTV, VoD and IPoE HSI Service (R7.0)

VPN Router

buil ding #3
Sa udi. ne t
Switc h/Route r

Sa udi.net
Switch/Route r

1 0 00 b T
Incognito Com ma nd Ce ntre
Applia nc e SUNV2 1 0

Re m ote Mgnt
connec tion v ia
VPN through
Sa udi.net

S AUD I .n et

STC Manag emen t Control C entre


bui lding 2, s uit e L rac k 5.

Sa udi.net
Ethe rne t Switc h

Incognito DHCP Clie nt


on Sa udi.net PC

Ra dius Se rve r
10 /10 0 bT
Incognito DHCP
Serv e r HSI

Saudi.n e t DNS Serv e r


(Ex is ting)

SUN T5 1 20
J unipe r SRC se rv er
(Ex is ting)

A XS Vis o
i n Se rve r
Incognito Com ma nd C entre
Appli a nce SUN V21 0

IPTV
Serv ic e
Ma nagem e nt

STC Mgnt
PC

STB
DHCP
Serv e r

AXSVis io n
Clie nt

Incognito CFM Prox y

10 /10 0 bT

1 0/1 00 b T

SAUDI.net

ST C EMS Mgnt V LAN


SAUDI.ne t
BRA SE3 2 0

OO B Mgnt
VPN

1 0 /1 00 b T

10 /10 0 bT

Inc ognito D HCP


Se rv er VoIP

1 0 /1 0 0b T

Incognito CFM Se rv er

Inc ognito
Clie nt
Softwa re

M ujamm ah, J eddah


In te rn et

VoD
Serv ic e
Ma nage m ent

1 0/1 00 b T

STC
Mgnt
PC

1 0/1 00 b T

1 0 /10 0 bT

STC DNS
Serv e r
(Ex is tin g)

S TC IPTV / V oD Mgnt VLAN

S TC V oice Mgnt V LAN

jd- dsl-e 6

PSTN
T runk Gateway

IPTV
He a de nd
STC
Voic e
Core

STC
Se s sion
B or de r
Controlle r
STC
Softs witc h

VoD
Hea dend
STC
Video
Se rvic es
Core

HSI
VPN

STC
HSI
Core

JE DA14- JEDA1 4 GE F 80
STC
Ma na ge m ent
Core

H u ttai n-Qair exchang e


R i yadh

OO B
N:1 VLA N
S-VID: 2 3

LEG END:

10 .141 .128 .1

STC Vo IP Netwo rk & Vo ci e M an a ge me n t Pro vi si o ni n g

R out er

STC GPO N Equ i pm en t Ma na g em en t Prov si i on i ng

Cisco
7609 PE

STC Co mmo n Serv i ce s Ne twork Prov si i on i ng


SAUDI.n et HSI & Data Ma n ag e me nt Prov i si on i ng
STC HSI Who l es al e Del i ve ry

B ridge

10 .202 .155 .14

Fuj i tsu Vo IP Netwo rk & Vo ci e M an a ge me n t Pro vi si o ni n g


Fu ij tsu GPON Eq ui p me nt M an a ge me nt Pro vi s o
i ni n g
Fu ij ts u GPON Eq u p
i me n t Pro v si o
i nn
i g
STC IPTV/ Vo D Tra ffi c a nd Ma na g em en t Core

STC OD F
LAG
L AG
Pro tec ted
11
00GGSX
SX

LAG
Pro e
t ce
t d
1 0 G SX

Ma n ag e me nt SVLAN: 1 0
J uniper EX3 2 00 -2 4-T-DC
e nteSwitc
t
Ethe rne
h

Au -9-1

IPTV
N:1 VLAN
S-VID: 1 50 0

VoD
N:1 VLAN
S-VID :1 5 01

P2

P3
P3

HSI
N:1 VLAN
S-VID: 3 0 45

1 0/1 00 b as eT

Switch
Proc e ss or1

1 0 /1 0 0b as e T

Cont F
I #2

10.202 .1 55.1
GPON
Ca rd # 1
2

GPO N
Ca rd # 1 4
4

GPON 5 3

54 55

56

GPO N DISTR B
I UTIO N

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

L2 S witch
P4

Loca l Acc e ss
Ethe rne t por t

Cont IF #1

Switch
Proc es s or 2

GPO N 1

50 v -B

1 0 /1 0 0b as e T

Au-8 -1
Voic e
N:1 VLA N
S-VID: 2 03 7

50 v -A

P1
1 00 0 ba se SX

2052501
M-FTE-00001

Typical Network Diagram


Page 10 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

RJ 4 5 Pa tch Pa ne l
For Loc al PC Ac ce s s

2.3

Typical End User Delivery Diagram

STC ODF

L AG
Pro tec ted
1 0 G SX

L AG
Pro tec ted
10 G SX

Au -8 -1

Au -9 -1

OL T M a na ge me n t I/Fs

c raft
HHT
Sw itc h
Proc es sor1

10 /10 0 bt
C ont IF # 1

Sw itc h
Proc es s or2

10 /10 0 bt
Cont IF # 2

GPO N
C ard #1
GPO N 1

GPON
Ca rd # 12
4

2 - Way

2- W ay

S pli t ter
#2

Sp il t er
#3

GPO N4 5

46

47

2- W ay

2- W ay

Spl ti t er
#45

Spl ti t er
#46

48

2 Way Spl i tte r #4

2 Way Spl ti te r# 1

2 Wa y Spl ti te r# 4 7

3 2 Way S pli t e
t r #7

3 2 Wa y Sp l ti te r# 1
Fi b re 1

32

Fib re 3 3

O
N
T
POTS

Ga te way
Ro ute r

32 Wa y Spl ti t er #93

3 2 Wa y Sp il tter # 2

3 2 Wa y Sp il tter # 8

64

Fib re 1 9 3

O
N
T
O
N
T

Fi bre 29 45

O
N
T

POTS

POTS

3 2 Wa y Sp il tter # 94

25 6

Ga te way
Rou te r

O
N
T

Ga te way
Ro ute r

O
N
T

PO TS

POTS

POTS

Ga tewa y
R ou ter

PO TS

L 2 Swit c h
L2 Swi tch

ST B
STB

Project Name
Mop Type
Eng. Name
Site Name

STB

STB

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

3 00 0
O
N
T

2052501
M-FTE-00001

Typical End User Delivery Diagram


Page 11 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

O
N
T
POTS

2.4
Configuration and Detailed Views
(111-00-000)
2.4.1 CO : 111-00-000 (00)

NO T ES
1. ALL DIMENSIONS ARE IN MILLIMETERS
UNLESS OTHERWISE NOTED.

4010

130

1500

6000

7200

1200

960

300

L EG END

200 300

300

300

300

APPROVED NOT INSTALLED


10

09

08

07

06

05

04

03

02

01

10

09

08

07

06

05

04

03

02

01

10

09

08

07

06

05

04

03

02

01

202.07

202.08

12

11

10

09

08

07

06

05

04

03

02

01

800

EXISTING EQUIPMENT
12

11

10

09

08

07

06

05

04

03

10

09

08

07

06

05

04

03

102B.08

102B.07

102B.06

102B.04

102A.08

102A.07

102A.06

102A.04

02

01

FUTURE EQUIPMENT
600

FUJITS U OLT

ADM

GP ON FDF

ADD/DROP MULTIPLEXER

800

HU AW EI
OD F
202.06

SC R Y
19

HU AWEI
OD F
202.11

OPTICAL DIST RIBUT ION FRAME

10

09

401B.01

401B.02

08

07

06

05

04

03

02

01

201.06

201.07

201.08

201.09

201.10

201.11

10

09

08

102B.03

102B.02

102B.01

SLM

102A.03

102A.02

102A.01

DCDP

ISM

ODF

07

06

05

04

DIGIT AL DISTRIBUTION FRAME

01

800

OD F

12

OPTICAL LINE SYST EM

Odf
DDF

600

13

6017

14

OLS

02

03

INTELLIGENT SYNCHRONOUS MULT IPLEXER

DIRECT CURRENT DIST RIBUT ION PANEL


LIGHT GUIDE COMBINATION
BASE TRANSCEIVER ST AT ION

01

DSX

WIN AX
CABINET
101.01

LTP

02

SYNCHRONOUS LINE MULTIPLEXER

LGX
BTS

DIGITAL SIGNAL CROSS CONNECT SYST EM

10

600

SMC
101.04

SW ITCHING MODULE CONT ROL CABINET


LINE T RUNK PERIPHERAL CABINET

ADM

ADD/DROP MULT IPLEXER

MI0

DDF

04

D DF

D DF

06

07

05

DD F

DDF

10

11

DD F

12
SIEMENS-J 2K

13

1740

600
340

SMC

002

001

LTP

000

LTP

SMC

001

D SX

2202

610

390

600

650

TH ERMOSTAT

80x 100.HT = 1000

05

900

LUC ENT

150

SM015

SMC

GPD F

STM-1

STM-1

STM-1

001

000

001

000

002

087

085

083

STM-1

DDF
FOR W LL

D DF

D DF

DDF

D DF

D DF

D DF

AHU
BASE

DD F

080
J UN C TION

RECT IFIER DISTRIBUTION BOARD


SYNCHRONOUS BAY
MAIN DISTRIBUTION FRAME

SLR16

SYNCHRONOUS LINE REGENERATOR 16

COMM.

COMMUNICATION CABINET

CAB.
ST M

SYNCHRONOUS T RANSPORT MODULE

OD F

WLL

WIRELESS LOCAL LOOP

01

CATU'S

CENT ER ACCESS AND TRANSCODING UNIT

810

790

1000

04

270
800

DDF

111

05
900

RECT IFIER
MULTI PURPOSE CONCENTRAT OR (TABLE MOUNT ED)

RDB

MDF

TIE C ABLE
112
STM-1

081

LOAD DISTRIBUTION BAY

LDB

SYNC
01

3X600=1800
FOR

SM014

LTP

RECT

04

001

000

100
SM016

SM013

SW C

RBS
2206

2202

LTP

SMC

001

000

660

SM017

SM012

BATT ERY SWIT CH BAY

MPC
R BS

R BS

06
580

ALC ATEL

150

HEIGHT FROM
FLOOR 4'-5"

113
LTP

LTP

000

082

100
LTP

ADMINISTRATION MODULE CABINET


MAINT ENANCE CONT ROL CENTER

MCC
BSB

401

14

5x 600=3000

9x 600= 5400

300

H UAW EI
D DF

SD H

09

08

INTERIM LD N

SMC

STM-1

DU C T

205

150

920

ISM

03

580
206

525

400

ISM

02

N EW
3G ADM
ABB

610

07

1420

ISM

01
75

150

600

TOLC U
HT:1240
N EW
3G AD M

480

260

100

ISM

580

COMMUNICATION MODULE NO. 2

AM
165

08

CM2

H EIGH T FR OM
FLOOR 3'-1"

C ISCO
D C DP

AT&T SDH
D CD P

DIGITAL ACCESS CROSS CONNECT SYSTEM


GLOBAL POW ER DISTRIBUT ION FRAME

GPDF

H EIGH T FR OM
FLOOR 3'-3"

250

MISCELLANEOUS CABINET

DACS

1317

09

HEIGH T FR OM
FLOOR 3'-4"

10x762+108=7728

7650

JU N CTION
Odf

000

SMC

LTP

SMC

001

000

GPD F

LTP

SMC

LTP

SMC

001

000

001

000

LTP

LTP

001

001

000

LTP

LTP

SMC

001

000

001

LTP

SMC

001

000

LTP

SDH

ISM

ISM
ISM

ISM

SD H

9202

600

TMR

109

001

ISM
01

SMC

001

000

002

800

ALAR M PANEL
300x 130
H T=1400

SM008

108

EMPTY

C ATU

C ATU

C ATU

CATU

107

AD M16/IC

C ATU

C ATU

C ATU

CATU

AHU
BASE

600

SM009

SM010

LTP

600

LTP

000

001

LD B 1

610

R i*51-1

LDB 2

610

200A.09

05
C R22

06

02

LD N
DC DP3

600

04
R i125-1

H U AW EI

C DMA
H U AW EI

9500

BTS

H UAWEI

D SLAM

1000

800
7650

660

660

660

03
Ri125-1

600

520

520x 500

45

01

660

D SL

D DF

660

REC T.2

R ECT.3

R EC T.4

R ECT.5

REC T.6

R ECT.7

REC T.8

400A

400A

400A

400A

400A

400A

400A

400A

660

580

600

250

300

750
RD B#2

850

450

425

3000

11970

640
680

H EIGH T FR OM
FLOOR 3'-1"
H EIGH T FR OM
FLOOR 3'-1"

EML/FU SE BOX
(125x 150x H T:1400)
360

AT & T
R.D .B.

POW ER
1330

480

152K ALAR M BOX HT:1400


(ER IC SSON)

650
HEIGHT FROM
FLOOR 1'-11"
320

85

414
1850

500
260

HT:950

1800

100

750

680

C ABLE LAD DER


W =240

E/L LIGH T SW
HALON GAS D IA.400

160X160

PORTS

HT:1400

TOILET

AXE RAC K LIGHTING SW.

GENERAT OR ROOM

HT:1000
ALARMS PAN EL

260

308

H EIGH T FR OM
FLOOR 4'-5"

1200

280

600

HU AWEI
OPTIX

16/1

16/1

HEIGH T FR OM
FLOOR 1'-11"
200

580

04

HEIGHT FROM
FLOOR 4'-5"

D AC S

ADM
16/1

580

16/1

LTII

800

280

01

600

03

ADM.

AD M.

600

200

PH -III

VER TIC ALD U CT


R CR #9
ADM

810

01

LDN
D CD P1

600

16/1

01

810

D DN
A111
BASIC
N OD E

BATB
500x 155
HT:1400

230

D C DP

600

C R#6/

AD M

16/1

101

MSC WORKSTATION

100

118
FOR INTE RNE T

FU T

LIGHT SW .
600

CR #11
AD M

H T:1350

FBDC

SIE MENS

950

H EIGHT FROM
FLOOR 4'-5"

H EIGH T FR OM
FLOOR 5'-4"
2x 600=1200
R IC R#14

150

200A

01

HEIGHT FROM
FLOOR 3'-4"

660

660

R ECT.1

SIEMENS

150

ER IC SON
Odf

40

04

2006

BR AS

HU AWEI

2500

130

ERIC SON
Odf
HU AWEI
OSN

08

710

400X400 (N OT U SED )

307

01
240

360

SIEMENS
DD F

EQPT.

5350

642

660
306

H T=1400

740
1800

CYLINK
DD N

600

07

BSB
01

642

FLOOR C U T-OUT

OLS
400G

600

02

150

05
OLS
400G

DD F

05

D DF

02

C AB
BSB

305
05

C MX11
CMXC S
SIEMEN S

SD H

AIRCONDITIONING ROOM

C ATU
DIGITEST
EDGE

D DF

D DF

660

102

300

SMC

001

260

304

D ACS
PORT

380

D ACS
PORT

5x 600 = 3000

LDN ROOM
HU AWEI

CATU

TBD

TN T
EXP.

Odf

103

AD M/1

IN TER NET-2B
BUS BAR
H T:3110

DACS
MATRIX
& SYN C

600

600

&CTRL

01

620

BAB

9202

PH -III

SM018

LTP

000

600

000

001

4X762+108=3156
SM019

SMC

18G

180

SMC

LTP

000

001

TDM

C OMM.
MATRIX
OSN
3500

01

600

SM003

SMC

LTP

000

200B

15 0 0 0 0

800

GPD F

06
600

ETH ER N ET
& PE
199

580

002

05

199.03

D CD P

LTP

000

600

STINGER
200.03

400

SMC

600

02
BSTDX
9000
200.02
199.02

2600

001

600

01

600

000

600

CBX
500
200.01
199.01

580

ADM
16/1
200.01E

WLL
D CD P

600
01E

02E

860

LTP

M10

000

600

D DN

303

DAC S4/ 4 /1

DACS

ISM

DD F

SD H

SYSTEM
01

560

SIEMENS
D DF
SM002

SM001

AM

201

AT&T
ALAR M PANEL
610x100

150

H U AW EI
D SLM
H EIGH T FR OM
FLOOR 3'-4"

302

05

SYSTEM

120

AD M-16
H U AW EI
DDF
120

400

120

VH F/U H F

BAC K

CAMOD S
205

800

DD F

AC C
5x 600= 3000

H EIGH T FR OM
FLOOR 3'-1"
TBD

106

TMR

410

301
05

R CR #5
AD M-16

AD M-16

600

SLR 16

01

H UAW EI
OSN
001

ODF

03

DC D P
AD M-16

SYN C

MISC. EQPT.

GSM-NER A D MW
(120x 260)
600
240
SIEMENS
H IT
7500

LAMBDA
U NIT

300

RC R #2

LAMBDA
U NIT

600

D DF

600

800

C ISC O
202.004

810

810

C ABLE

ADM-16

5x 600=3000

SM007

TALK
C ISC O
202.003

610
LGX

FAN TRAN SFER


SWITC H(160x 140)
HT=1400
R CR #4

FOR TIE

600

DD F

4x 600=2400

RC R#1

840

15300

300

DD F

DD F

150

SM006

5ESS-SERVICE NODE

C ISC O
202.002

202

SIEMEN S FBD C
TEP7 (300x 130)

800
D SL&MISC
H EIGH T FR OM
FLOOR 3'-4"

Odf

D DF
150

NER #1

SM005

SM004

01

WALL C U T-OUT
450X350
H T:2990

900

810

900

600

FIBER OPTIC

v
900

150

1200
1120

1400

150

C ABLE AC C ESS

900

05

270

01

600

620

05
SM011

203

9150

SMC

270

600
H T:3210

500X200

03

W ALL CU T-OU T

900

02

VACAN T

900

M D F ROOM

LTP
002

SD H

TELLABS

110
204

LD N
D C DP2

02

18-03-2006

01

26Nov2005

AS-BUILT

27-08-2001

AS-BUILT

DSL 2006 PROJECT

100

OLS

350

300

OLS

CONFIDENTIALITY:
TH IS D RAW ING IS TH E PR OPERTY OF THE SAU D I TELEC OM C OMPAN Y (STC).

100

LGX

REV

DOWN

04
309

LGX

TH E IN FOR MATION CON TAIN ED H ER EIN SHALL N OT BE USED OR C OPIED IN ANY


580

MAN N ER W ITH OU T WR ITTEN PERMISSION OF EN GINEERIN G PLANN ING DEPARTMEN T

200

APPROVED BU T NOT INSTALLED


R E-USE SPACE FOR INTERN ET
2185

D C DP (AS R EQU IR ED)

SAUDI T ELECOM
SITE: HUTTAYN - 111
GROUND FLOOR
EQUIPMENT FLOOR PLAN
DRAWN: ZEESHAN

HUTTEIN 111-00

DESIGNED: NP-ST C

SCALE: 1 :1

VERIFIED BY: USMAN ALEEM

UPDATED BY DETASAD
DATED: 14-07-2008

DRAWING NO.

CHECKED BY: SYED ASIF HUSSAIN

111-06AB

UPDAT ED BY DETASAD

2.4.2 CO : 111-00-000 (00)


Structure Unit Model
ETSI-22Hx6Wx6D-RK
ETSI-22Hx8.4Wx3D

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

Location Code
00.104.01
00.104.02

2052501
M-FTE-00001

Configuration and Detailed Views


Page 12 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

Project Name
Mop Type
Eng. Name

Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN
AU-0 3
AU-0 4

TEMPORARY FEATURE FOR OOB MANAGEMENT

Chassis Model Name


WA_2F_10TB_PDU
JU_EX3200_24T_DC_Shf
MO_AXS1800_OLT_SHELF
AGPONC: 4-Port Asymmetric GPON
AGPONC: 4-Port Asymmetric GPON

AU-06
AU-07
AU-1 0
AU-1 1
AU-1 2
AU-13
AU-14

AGPONC: 4-Port Asymmetric GPON


AGPONC: 4-Port Asymmetric GPON

TB07 TB08

MOTOROLA

ASYSC: System Controller

AU-0 9

AGPONC: 4-Port Asymmetric GPON

TB04 TB05 T B0 6

ASYSC: System Controller

AU-0 8

AGPONC: 4-Port Asymmetric GPON

SW-B

AGPONC: 4-Port Asymmetric GPON

SW-A

AGPONC: 4-Port Asymmetric GPON

T B0 1T B0 2 TB03

AGPONC: 4-Port Asymmetric GPON

F 01

ASW200D: 200Gbps Ethernet Switch Card

1 0A : 10A F use

TB: T erm i na tio n Blo c k

TB: T erm i na tio n Blo c k

TB: T erm i na tio n Blo c k

TB: T erm i na tio n Blo c k

TB: T erm i na tio n Blo c k

TB: T erm i na tio n Blo c k

TB: T erm i na tio n Blo c k

1 0A : 10A F use

TB: T erm i na tio n Blo c k

TB: T erm i na tio n Blo c k

TB: T erm i na tio n Blo c k

01

ASW200D: 200Gbps Ethernet Switch Card

AGPONC: 4-Port Asymmetric GPON

AU-05

AGPONC: 4-Port Asymmetric GPON

AGPONC: 4-Port Asymmetric GPON

AU-0 2

AGPONC: 4-Port Asymmetric GPON

20
AU-0 1

AGPONC: 4-Port Asymmetric GPON

2.4.3 OLT RACK FACE LAYOUT : 00.104.01 (00.104.01)

FUJITSU OLT
ETSI Rack
F0 2

Wag o Power Di s trib uti on Uni t

T B0 9 TB10

P01

10
AXS1800

SYS-A

SYS-B

P02

30

40

50

P03

60

Juniper EX3200 DC Switch Shelf


SF P Up l in k M o du le
Upl in k Slo t

70

P04

80

2.4.4 OLT RACK EQUIPMENT LIST : 00.104.01 00.104.01)

Location Code
00.104.01/PO1
00.104.01/PO4
00.104.01/PO2

2052501
M-FTE-00001

(111-00-000)
Page 13 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

Project Name
Mop Type
Eng. Name

Site Name
AU-02
AU-03
AU-04
AU-05
AU-06

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

AGPOND: 4-Port Assymmetric GPON


AGPOND: 4-Port Assymmetric GPON
AGPOND: 4-Port Assymmetric GPON
AGPOND: 4-Port Assymmetric GPON
AGPOND: 4-Port Assymmetric GPON

AU-09
AU-10
AU-11
AU-12
AU-13
AU-14

AGPOND: 4-Port Assymmetric GPON


AGPOND: 4-Port Assymmetric GPON
AGPOND: 4-Port Assymmetric GPON
AGPOND: 4-Port Assymmetric GPON
AGPOND: 4-Port Assymmetric GPON
SYS-B

ASYSC: System Controller

MOTOROLA

ASYSC: System Controller

AU-08

AGPOND: 4-Port Assymmetric GPON

SW-B

AGPOND: 4-Port Assymmetric GPON

SW-A

ASW200D: 200Gbps Ethernet Switch Card

AU-07

ASW200D: 200Gbps Ethernet Switch Card

AGPOND: 4-Port Assymmetric GPON

AU-01

AGPOND: 4-Port Assymmetric GPON

2.4.5 OLT SUB RACK LAYOUT : 00.104.01/PO2 (00.104.01) :


00.104.01/PO2

AXS1800

SYS-A

2052501
M-FTE-00001

(111-00-000)
Page 14 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

2.4.6 OLT SUB RACK EQUIPTMENT LIST : 00.104.01/PO2


(00.104.01) : 00.104.01/PO2

Project Name
Mop Type
Eng. Name
Site Name

Slots
SLOT AU-01

MO-AXS1800-OLT-SHELF
Plugins
MO-AXS1800-AGPOND

SLOT AU-02

MO-AXS1800-AGPOND

SLOT AU-03

MO-AXS1800-AGPOND

SLOT AU-04

MO-AXS1800-AGPOND

SLOT AU-05

MO-AXS1800-AGPOND

SLOT AU-06

MO-AXS1800-AGPOND

SLOT AU-07

MO-AXS1800-AGPOND

SLOT SW-A

MO-AXS1800-ASW200D
Interfaces
- SLOT XFP: PORT 01 / MO-XFP10GE-LR

SLOT SW-B

MO-AXS1800-ASW200D
Interfaces
- SLOT XFP: PORT 01 / MO-XFP10GE-LR

SLOT AU-08

MO-AXS1800-AGPOND

SLOT AU-09

MO-AXS1800-AGPOND

SLOT AU-10

MO-AXS1800-AGPOND

SLOT AU-11

MO-AXS1800-AGPOND

SLOT AU-12

MO-AXS1800-AGPOND

SLOT AU-13

MO-AXS1800-AGPOND

SLOT AU-14

MO-AXS1800-AGPOND

SLOT SYS-A

MO-AXS1800-ASYSC

SLOT SYS-B

MO-AXS1800-ASYSC

SLOT FAN

MO-AXS1800-FAN

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

Descriptions
Motorola AXS1800 Asymmetric GPON
Card
Motorola AXS1800 Asymmetric GPON
Card
Motorola AXS1800 Asymmetric GPON
Card
Motorola AXS1800 Asymmetric GPON
Card
Motorola AXS1800 Asymmetric GPON
Card
Motorola AXS1800 Asymmetric GPON
Card
Motorola AXS1800 Asymmetric GPON
Card
Motorola AXS1800 200Gbps Ethernet
Switch Card
Interfaces
- Motorola AXS1800 XFP 10GEthernet, 10
km with a duplex LC connector
Motorola AXS1800 200Gbps Ethernet
Switch Card
Interfaces
- Motorola AXS1800 XFP 10GEthernet, 10
km with a duplex LC connector
Motorola AXS1800 Asymmetric GPON
Card
Motorola AXS1800 Asymmetric GPON
Card
Motorola AXS1800 Asymmetric GPON
Card
Motorola AXS1800 Asymmetric GPON
Card
Motorola AXS1800 Asymmetric GPON
Card
Motorola AXS1800 Asymmetric GPON
Card
Motorola AXS1800 Asymmetric GPON
Card
Motorola AXS1800 System Controller
Card
Motorola AXS1800 System Controller
Card

2052501
M-FTE-00001

(111-00-000)
Page 15 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

2.4.7 OOB MANAGEMENT SWITCH (00.104.01) :

Juniper EX3200 DC Switch Shelf


Uplink Slot
SFP Uplink Module

2.4.8 OOB MANAGEMENT EQUIPTMENT LIST (00.104.01) :


Slots
SLOT UP

JU-EX3200-24T-DC-Shf
Plugins
JU-EX3200/4200-SFP
Interfaces
- PORT 01 / JU-SFP-SX

Descriptions
4-Port GbE Module With Pluggable SFP
Optics
Interfaces
- Small Form-Factor Pluggable-SX CardSX

Note : Temporary feature for OOB Management.

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

(111-00-000)
Page 16 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

2.4.9 FDF RACK FACE LAYOUT : 00.104.02 (00.104.02)

FUJITSU FDF
P ODF01(1-72)

ATC ODF 72 PORTS

P ODF02(73-144)

ATC ODF 72 PORTS

P ODF03(145-216)

ATC ODF 72 PORTS

P ODF04(217-288)

ATC ODF 72 PORTS

P ODF05(1-72)

ATC ODF 72 PORTS

P ODF06(73-144)

ATC ODF 72 PORTS

P ODF07(145-216)

ATC ODF 72 PORTS

P ODF08(216-288)

ATC ODF 72 PORTS

FOR FUTURE
ODF
EXPANSION

FOR FUTURE
SPLITTER
EXPANSION

P SP07(49-56)
P SP06(41-48)
P SP05(33-40)
P SP04(25-32)
P SP03(17-24)
P SP02(9-16)
P SP01(1-8)

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

AMWAJ: 8x1:2 Optical Splitter LC/APC


AMWAJ: 8x1:2 Optical Splitter LC/APC
AMWAJ: 8x1:2 Optical Splitter LC/APC
AMWAJ: 8x1:2 Optical Splitter LC/APC
AMWAJ: 8x1:2 Optical Splitter LC/APC
AMWAJ: 8x1:2 Optical Splitter LC/APC
AMWAJ: 8x1:2 Optical Splitter LC/APC

2052501
M-FTE-00001

(111-00-000)
Page 17 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

2.4.10
FDF RACK EQUIPTMENT LIST : 00.104.02
(00.104.02)

Chassis Model Name


ATC_PLT_SPLT_8x1:2_S
ATC_PLT_SPLT_8x1:2_S
ATC_PLT_SPLT_8x1:2_S
ATC_PLT_SPLT_8x1:2_S
ATC_PLT_SPLT_8x1:2_S
ATC_PLT_SPLT_8x1:2_S
ATC_PLT_SPLT_8x1:2_S
ATC_ODF_72P_PNL
ATC_ODF_72P_PNL
ATC_ODF_72P_PNL
ATC_ODF_72P_PNL
ATC_ODF_72P_PNL
ATC_ODF_72P_PNL
ATC_ODF_72P_PNL
ATC_ODF_72P_PNL

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

Location Code
00.104.02/P SP02 (9-16)
00.104.02/P SP01 (1-8)
00.104.02/P SP03 (17-24)
00.104.02/P SP04 (25-32)
00.104.02/P SP05 (33-40)
00.104.02/P SP06 (41-48)
00.104.02/P SP07 (49-56)
00.104.02/P ODF01 (1-72)
00.104.02/P ODF02 (73-144)
00.104.02/P ODF03 (145-216)
00.104.02/P ODF04 (217-288)
00.104.02/P ODF05 (1-72)
00.104.02/P ODF06 (361-432)
00.104.02/P ODF07 (145-216)
00.104.02/P ODF08 (505-576)

2052501
M-FTE-00001

(111-00-000)
Page 18 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

2.5

Physical and Logical Addressing Tables

2.5.1 111-00-000 : MO-AXS1800-OLT (GPON)

GPON Termination
Site Number : 111-00-000
Connections To

MO-AXS1800-OLT

ATC-PLT-SPLT-8x1:2

From Chassis
Location

From Slot
Name

From
Plugin
Name

From Port
Name

To Chassis Location

To Port Name

00.104.01/PO2

SLOT AU01

MOAXS1800AGPOND

PORT 01

00.104.02/P
SP01 (1-8)

SP01-IN

01

00.104.01/PO2

SLOT AU01

MOAXS1800AGPOND

PORT 02

00.104.02/P
SP01 (1-8)

SP02-IN

02

00.104.01/PO2

SLOT AU01

MOAXS1800AGPOND

PORT 03

00.104.02/P
SP01 (1-8)

SP03-IN

03

00.104.01/PO2

SLOT AU01

MOAXS1800AGPOND

PORT 04

00.104.02/P
SP01 (1-8)

SP04-IN

04

00.104.01/PO2

SLOT AU02

MOAXS1800AGPOND

PORT 01

00.104.02/P
SP01 (1-8)

SP05-IN

05

00.104.01/PO2

SLOT AU02

MOAXS1800AGPOND

PORT 02

00.104.02/P
SP01 (1-8)

SP06-IN

06

00.104.01/PO2

SLOT AU02

MOAXS1800AGPOND

PORT 03

00.104.02/P
SP01 (1-8)

SP07-IN

07

00.104.01/PO2

SLOT AU02

MOAXS1800AGPOND

PORT 04

00.104.02/P
SP01 (1-8)

SP08-IN

08

00.104.01/PO2

SLOT AU03

MOAXS1800AGPOND

PORT 01

00.104.02/P
SP02 (9-16)

SP01-IN

09

00.104.01/PO2

SLOT AU03

MOAXS1800AGPOND

PORT 02

00.104.02/P
SP02 (9-16)

SP02-IN

10

00.104.01/PO2

SLOT AU03

MOAXS1800AGPOND

PORT 03

00.104.02/P
SP02 (9-16)

SP03-IN

11

00.104.01/PO2

SLOT AU03

MOAXS1800AGPOND

PORT 04

00.104.02/P
SP02 (9-16)

SP04-IN

12

00.104.01/PO2

SLOT AU04

MOAXS1800AGPOND

PORT 01

00.104.02/P
SP02 (9-16)

SP05-IN

13

00.104.01/PO2

SLOT AU04

MOAXS1800AGPOND

PORT 02

00.104.02/P
SP02 (9-16)

SP06-IN

14

00.104.01/PO2

SLOT AU04

MOAXS1800AGPOND

PORT 03

00.104.02/P
SP02 (9-16)

SP07-IN

15

00.104.01/PO2

SLOT AU04

MOAXS1800AGPOND

PORT 04

00.104.02/P
SP02 (9-16)

SP08-IN

16

Project Name
Mop Type
Eng. Name
Site Name

Connections From

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Physical and Logical Addressing Tables


Page 19 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

Logical Port
Address

00.104.01/PO2

SLOT AU05

MOAXS1800AGPOND

PORT 01

00.104.02/P
SP03 (17-24)

SP01-IN

17

00.104.01/PO2

SLOT AU05

MOAXS1800AGPOND

PORT 02

00.104.02/P
SP03 (17-24)

SP02-IN

18

00.104.01/PO2

SLOT AU05

MOAXS1800AGPOND

PORT 03

00.104.02/P
SP03 (17-24)

SP03-IN

19

00.104.01/PO2

SLOT AU05

MOAXS1800AGPOND

PORT 04

00.104.02/P
SP03 (17-24)

SP04-IN

20

00.104.01/PO2

SLOT AU06

MOAXS1800AGPOND

PORT 01

00.104.02/P
SP03 (17-24)

SP05-IN

21

00.104.01/PO2

SLOT AU06

MOAXS1800AGPOND

PORT 02

00.104.02/P
SP03 (17-24)

SP06-IN

22

00.104.01/PO2

SLOT AU06

MOAXS1800AGPOND

PORT 03

00.104.02/P
SP03 (17-24)

SP07-IN

23

00.104.01/PO2

SLOT AU06

MOAXS1800AGPOND

PORT 04

00.104.02/P
SP03 (17-24)

SP08-IN

24

00.104.01/PO2

SLOT AU07

MOAXS1800AGPOND

PORT 01

00.104.02/P
SP04 (25-32)

SP01-IN

25

00.104.01/PO2

SLOT AU07

MOAXS1800AGPOND

PORT 02

00.104.02/P
SP04 (25-32)

SP02-IN

26

00.104.01/PO2

SLOT AU07

MOAXS1800AGPOND

PORT 03

00.104.02/P
SP04 (25-32)

SP03-IN

27

00.104.01/PO2

SLOT AU07

MOAXS1800AGPOND

PORT 04

00.104.02/P
SP04 (25-32)

SP04-IN

28

00.104.01/PO2

SLOT AU08

MOAXS1800AGPOND

PORT 01

00.104.02/P
SP04 (25-32)

SP05-IN

29

00.104.01/PO2

SLOT AU08

MOAXS1800AGPOND

PORT 02

00.104.02/P
SP04 (25-32)

SP06-IN

30

00.104.01/PO2

SLOT AU08

MOAXS1800AGPOND

PORT 03

00.104.02/P
SP04 (25-32)

SP07-IN

31

00.104.01/PO2

SLOT AU08

MOAXS1800AGPOND

PORT 04

00.104.02/P
SP04 (25-32)

SP08-IN

32

00.104.01/PO2

SLOT AU09

MOAXS1800AGPOND

PORT 01

00.104.02/P
SP05 (33-40)

SP01-IN

33

00.104.01/PO2

SLOT AU09

MOAXS1800AGPOND

PORT 02

00.104.02/P
SP05 (33-40)

SP02-IN

34

00.104.01/PO2

SLOT AU09

MOAXS1800AGPOND

PORT 03

00.104.02/P
SP05 (33-40)

SP03-IN

35

00.104.01/PO2

SLOT AU09

MOAXS1800AGPOND

PORT 04

00.104.02/P
SP05 (33-40)

SP04-IN

36

00.104.01/PO2

SLOT AU10

MOAXS1800AGPOND

PORT 01

00.104.02/P
SP05 (33-40)

SP05-IN

37

00.104.01/PO2

SLOT AU10

MOAXS1800AGPOND

PORT 02

00.104.02/P
SP05 (33-40)

SP06-IN

38

00.104.01/PO2

SLOT AU10

MOAXS1800AGPOND

PORT 03

00.104.02/P
SP05 (33-40)

SP07-IN

39

00.104.01/PO2

SLOT AU10

MOAXS1800AGPOND

PORT 04

00.104.02/P
SP05 (33-40)

SP08-IN

40

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Physical and Logical Addressing Tables


Page 20 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

00.104.01/PO2

SLOT AU11

MOAXS1800AGPOND

PORT 01

00.104.02/P
SP06 (41-48)

SP01-IN

41

00.104.01/PO2

SLOT AU11

MOAXS1800AGPOND

PORT 02

00.104.02/P
SP06 (41-48)

SP02-IN

42

00.104.01/PO2

SLOT AU11

MOAXS1800AGPOND

PORT 03

00.104.02/P
SP06 (41-48)

SP03-IN

43

00.104.01/PO2

SLOT AU11

MOAXS1800AGPOND

PORT 04

00.104.02/P
SP06 (41-48)

SP04-IN

44

00.104.01/PO2

SLOT AU12

MOAXS1800AGPOND

PORT 01

00.104.02/P
SP06 (41-48)

SP05-IN

45

00.104.01/PO2

SLOT AU12

MOAXS1800AGPOND

PORT 02

00.104.02/P
SP06 (41-48)

SP06-IN

46

00.104.01/PO2

SLOT AU12

MOAXS1800AGPOND

PORT 03

00.104.02/P
SP06 (41-48)

SP07-IN

47

00.104.01/PO2

SLOT AU12

MOAXS1800AGPOND

PORT 04

00.104.02/P
SP06 (41-48)

SP08-IN

48

00.104.01/PO2

SLOT AU13

MOAXS1800AGPOND

PORT 01

00.104.02/P
SP07 (49-56)

SP01-IN

49

00.104.01/PO2

SLOT AU13

MOAXS1800AGPOND

PORT 02

00.104.02/P
SP07 (49-56)

SP02-IN

50

00.104.01/PO2

SLOT AU13

MOAXS1800AGPOND

PORT 03

00.104.02/P
SP07 (49-56)

SP03-IN

51

00.104.01/PO2

SLOT AU13

MOAXS1800AGPOND

PORT 04

00.104.02/P
SP07 (49-56)

SP04-IN

52

00.104.01/PO2

SLOT AU14

MOAXS1800AGPOND

PORT 01

00.104.02/P
SP07 (49-56)

SP05-IN

53

00.104.01/PO2

SLOT AU14

MOAXS1800AGPOND

PORT 02

00.104.02/P
SP07 (49-56)

SP06-IN

54

00.104.01/PO2

SLOT AU14

MOAXS1800AGPOND

PORT 03

00.104.02/P
SP07 (49-56)

SP07-IN

55

00.104.01/PO2

SLOT AU14

MOAXS1800AGPOND

PORT 04

00.104.02/P
SP07 (49-56)

SP08-IN

56

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Physical and Logical Addressing Tables


Page 21 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

2.5.2 111-00-000 : ATC-PLT-SPLT-8x1:2 (OUT)

OUT Termination
Site Number : 111-00-000

From Chassis Location

Connections From

Connections To

ATC-PLT-SPLT-8x1:2

ATC-ODF-72P

Logical Splitter
Port Address

00.104.02/P SP01 (1-8)


00.104.02/P SP01 (1-8)

01

00.104.02/P SP01 (1-8)


00.104.02/P SP01 (1-8)

02

00.104.02/P SP01 (1-8)


00.104.02/P SP01 (1-8)

03

00.104.02/P SP01 (1-8)


00.104.02/P SP01 (1-8)

04

00.104.02/P SP01 (1-8)


00.104.02/P SP01 (1-8)

05

00.104.02/P SP01 (1-8)


00.104.02/P SP01 (1-8)

06

00.104.02/P SP01 (1-8)


00.104.02/P SP01 (1-8)

07

00.104.02/P SP01 (1-8)


00.104.02/P SP01 (1-8)

Project Name
Mop Type
Eng. Name
Site Name

08

From Port Name

To Chassis Location

To Port Name

SP01-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 01

Logical ODF Port


Address
01

SP01-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 02

02

SP02-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 03

03

SP02-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 04

04

SP03-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 05

05

SP03-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 06

06

SP04-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 07

07

SP04-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 08

08

SP05-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 09

09

SP05-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 10

10

SP06-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 11

11

SP06-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 12

12

SP07-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 13

13

SP07-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 14

14

SP08-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 15

15

SP08-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 16

16

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Physical and Logical Addressing Tables


Page 22 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

OUT Termination
Site Number : 111-00-000

From Chassis Location

Connections From

Connections To

ATC-PLT-SPLT-8x1:2

ATC-ODF-72P

Logical Splitter Port


Address

00.104.02/P SP02 (9-16)


00.104.02/P SP02 (9-16)

09

00.104.02/P SP02 (9-16)


00.104.02/P SP02 (9-16)

10

00.104.02/P SP02 (9-16)


00.104.02/P SP02 (9-16)

11

00.104.02/P SP02 (9-16)


00.104.02/P SP02 (9-16)

12

00.104.02/P SP02 (9-16)


00.104.02/P SP02 (9-16)

13

00.104.02/P SP02 (9-16)


00.104.02/P SP02 (9-16)

14

00.104.02/P SP02 (9-16)


00.104.02/P SP02 (9-16)

15

00.104.02/P SP02 (9-16)


00.104.02/P SP02 (9-16)

Project Name
Mop Type
Eng. Name
Site Name

16

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

From Port Name

To Chassis Location

To Port Name

SP01-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 17

17

SP01-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 18

18

SP02-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 19

19

SP02-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 20

20

SP03-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 21

21

SP03-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 22

22

SP04-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 23

23

SP04-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 24

24

SP05-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 25

25

SP05-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 26

26

SP06-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 27

27

SP06-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 28

28

SP07-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 29

29

SP07-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 30

30

SP08-OUT: 01

00.104.02/P ODF01 (1-72)

PORT 31

31

SP08-OUT: 02

00.104.02/P ODF01 (1-72)

PORT 32

32

2052501
M-FTE-00001

Physical and Logical Addressing Tables


Page 23 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

Logical ODF Port


Address

Termination
Site Number : 111-00-000

From Chassis Location

Connections From

Connections To

ATC-PLT-SPLT-8x1:2

ATC-ODF-72P

Logical Splitter Port


Address

00.104.02/P SP03 (17-24)


00.104.02/P SP03 (17-24)

17

00.104.02/P SP03 (17-24)


00.104.02/P SP03 (17-24)

18

00.104.02/P SP03 (17-24)


00.104.02/P SP03 (17-24)

19

00.104.02/P SP03 (17-24)


00.104.02/P SP03 (17-24)

20

00.104.02/P SP03 (17-24)


00.104.02/P SP03 (17-24)

21

00.104.02/P SP03 (17-24)


00.104.02/P SP03 (17-24)

22

00.104.02/P SP03 (17-24)


00.104.02/P SP03 (17-24)

23

00.104.02/P SP03 (17-24)


00.104.02/P SP03 (17-24)

Project Name
Mop Type
Eng. Name
Site Name

24

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

From Port Name

To Chassis Location

SP01-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 01

Logical ODF Port


Address
73

SP01-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 02

74

SP02-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 03

75

SP02-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 04

76

SP03-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 05

77

SP03-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 06

78

SP04-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 07

79

SP04-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 08

80

SP05-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 09

81

SP05-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 10

82

SP06-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 11

83

SP06-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 12

84

SP07-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 13

85

SP07-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 14

86

SP08-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 15

87

SP08-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 16

88

2052501
M-FTE-00001

Physical and Logical Addressing Tables


Page 24 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

To Port Name

OUT Termination
Site Number : 111-00-000

From Chassis Location

Connections From

Connections To

ATC-PLT-SPLT-8x1:2

ATC-ODF-72P

Logical Port Address

00.104.02/P SP04 (25-32)


00.104.02/P SP04 (25-32)

25

00.104.02/P SP04 (25-32)


00.104.02/P SP04 (25-32)

26

00.104.02/P SP04 (25-32)


00.104.02/P SP04 (25-32)

27

00.104.02/P SP04 (25-32)


00.104.02/P SP04 (25-32)

28

00.104.02/P SP04 (25-32)


00.104.02/P SP04 (25-32)

29

00.104.02/P SP04 (25-32)


00.104.02/P SP04 (25-32)

30

00.104.02/P SP04 (25-32)


00.104.02/P SP04 (25-32)

31

00.104.02/P SP04 (25-32)


00.104.02/P SP04 (25-32)

Project Name
Mop Type
Eng. Name
Site Name

32

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

From Port Name

To Chassis Location

To Port Name

Logical Port Address

SP01-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 17

89

SP01-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 18

90

SP02-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 19

91

SP02-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 20

92

SP03-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 21

93

SP03-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 22

94

SP04-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 23

95

SP04-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 24

96

SP05-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 25

97

SP05-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 26

98

SP06-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 27

99

SP06-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 28

100

SP07-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 29

101

SP07-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 30

102

SP08-OUT: 01

00.104.02/P ODF02 (73-144)

PORT 31

103

SP08-OUT: 02

00.104.02/P ODF02 (73-144)

PORT 32

104

2052501
M-FTE-00001

Physical and Logical Addressing Tables


Page 25 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

OUT Termination
Site Number : 111-00-000

From Chassis Location

Connections From

Connections To

ATC-PLT-SPLT-8x1:2

ATC-ODF-72P

Logical Port Address

00.104.02/P SP05 (33-40)


00.104.02/P SP05 (33-40)

33

00.104.02/P SP05 (33-40)


00.104.02/P SP05 (33-40)

34

00.104.02/P SP05 (33-40)


00.104.02/P SP05 (33-40)

35

00.104.02/P SP05 (33-40)


00.104.02/P SP05 (33-40)

36

00.104.02/P SP05 (33-40)


00.104.02/P SP05 (33-40)

37

00.104.02/P SP05 (33-40)


00.104.02/P SP05 (33-40)

38

00.104.02/P SP05 (33-40)


00.104.02/P SP05 (33-40)

39

00.104.02/P SP05 (33-40)


00.104.02/P SP05 (33-40)

Project Name
Mop Type
Eng. Name
Site Name

40

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

From Port Name

To Chassis Location

To Port Name

Logical Port Address

SP01-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 01

01

SP01-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 02

02

SP02-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 03

03

SP02-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 04

04

SP03-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 05

05

SP03-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 06

06

SP04-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 07

07

SP04-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 08

08

SP05-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 09

09

SP05-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 10

10

SP06-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 11

11

SP06-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 12

12

SP07-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 13

13

SP07-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 14

14

SP08-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 15

15

SP08-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 16

16

2052501
M-FTE-00001

Physical and Logical Addressing Tables


Page 26 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

OUT Termination
Site Number : 111-00-000

From Chassis Location

Connections From

Connections To

ATC-PLT-SPLT-8x1:2

ATC-ODF-72P

Logical Splitter Port


Address

00.104.02/P SP06 (41-48)


00.104.02/P SP06 (41-48)

41

00.104.02/P SP06 (41-48)


00.104.02/P SP06 (41-48)

42

00.104.02/P SP06 (41-48)


00.104.02/P SP06 (41-48)

43

00.104.02/P SP06 (41-48)


00.104.02/P SP06 (41-48)

44

00.104.02/P SP06 (41-48)


00.104.02/P SP06 (41-48)

45

00.104.02/P SP06 (41-48)


00.104.02/P SP06 (41-48)

46

00.104.02/P SP06 (41-48)


00.104.02/P SP06 (41-48)

47

00.104.02/P SP06 (41-48)


00.104.02/P SP06 (41-48)

Project Name
Mop Type
Eng. Name
Site Name

48

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

From Port Name

To Chassis Location

To Port Name

Logical ODF Port


Address

SP01-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 17

17

SP01-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 18

18

SP02-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 19

19

SP02-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 20

20

SP03-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 21

21

SP03-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 22

22

SP04-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 23

23

SP04-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 24

24

SP05-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 25

25

SP05-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 26

26

SP06-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 27

27

SP06-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 28

28

SP07-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 29

29

SP07-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 30

30

SP08-OUT: 01

00.104.02/P ODF05 (1-72)

PORT 31

31

SP08-OUT: 02

00.104.02/P ODF05 (1-72)

PORT 32

32

2052501
M-FTE-00001

Physical and Logical Addressing Tables


Page 27 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

OUT Termination
Site Number : 111-00-000

From Chassis Location

Connections From

Connections To

ATC-PLT-SPLT-8x1:2

ATC-ODF-72P

Logical Splitter Port


Address

00.104.02/P SP07 (49-56)


00.104.02/P SP07 (49-56)

49

00.104.02/P SP07 (49-56)


00.104.02/P SP07 (49-56)

50

00.104.02/P SP07 (49-56)


00.104.02/P SP07 (49-56)

51

00.104.02/P SP07 (49-56)


00.104.02/P SP07 (49-56)

52

00.104.02/P SP07 (49-56)


00.104.02/P SP07 (49-56)

53

00.104.02/P SP07 (49-56)


00.104.02/P SP07 (49-56)

54

00.104.02/P SP07 (49-56)


00.104.02/P SP07 (49-56)

55

00.104.02/P SP07 (49-56)


00.104.02/P SP07 (49-56)

Project Name
Mop Type
Eng. Name
Site Name

56

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

From Port Name

To Chassis Location

SP01-OUT: 01

00.104.02/P ODF06 (73-144)

PORT 01

Logical ODF Port


Address
73

SP01-OUT: 02

00.104.02/P ODF06 (73-144)

PORT 02

74

SP02-OUT: 01

00.104.02/P ODF06 (73-144)

PORT 03

75

SP02-OUT: 02

00.104.02/P ODF06 (73-144)

PORT 04

76

SP03-OUT: 01

00.104.02/P ODF06 (73-144)

PORT 05

77

SP03-OUT: 02

00.104.02/P ODF06 (73-144)

PORT 06

78

SP04-OUT: 01

00.104.02/P ODF06 (73-144)

PORT 07

79

SP04-OUT: 02

00.104.02/P ODF06 (73-144)

PORT 08

80

SP05-OUT: 01

00.104.02/P ODF06 (73-144)

PORT 09

81

SP05-OUT: 02

00.104.02/P ODF06 (73-144)

PORT 10

82

SP06-OUT: 01

00.104.02/P ODF06 (73-144)

PORT 11

83

SP06-OUT: 02

00.104.02/P ODF06 (73-144)

PORT 12

84

SP07-OUT: 01

00.104.02/P ODF06 (73-144)

PORT 13

85

SP07-OUT: 02

00.104.02/P ODF06 (73-144)

PORT 14

86

SP08-OUT: 01

00.104.02/P ODF06 (73-144)

PORT 15

87

SP08-OUT: 02

00.104.02/P ODF06 (73-144)

PORT 16

88

2052501
M-FTE-00001

Physical and Logical Addressing Tables


Page 28 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

To Port Name

2.6

Network Connectivity Diagram

00.104.01/P02

FROM OLT to STC ODF


OLT
Equipment

Site

Flr.Row.Bay/Pos

Slot

Port

Cable Type

AXS1800

HUTTAYN

00.104.01/P02

SW-A

AXS1800

HUTTAYN

00.104.01/P02

SW-B

PRIMARY DUPLEX
LC/FC SINGLE
MODE
SECONDARY
DUPLEX LC/FC
SINGLE MODE

Equipment

Site

Flr.Row.Bay/Pos

Panel

STC ODF

HUTTAYN

00.201.07

02

1Rx
2Tx

STC ODF

HUTTAYN

00.201.07

02

7Rx
8Tx

Equipment

Site

Flr.Row.Bay/Pos

Slot

Port

CISCO 7609
CISCO 7609

HUTTAYN
HUTTAYN

00.201.06/01
00.201.06/01

1
2

0
1

STC ODF
Ports

Cable Type

PRIMARY DUPLEX
LC/FC SINGLE
MODE
SECONDARY
DUPLEX LC/FC
SINGLE MODE

STC ODF to ETHERNET SWITCH

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Network Connectivity Diagram


Page 29 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

PRIMARY EA
SECONDARY EA

Network Connectivity Diagram

Eth ern et Agg regato r


111-11

OD F

00.20 2.02/01

00 .2 02.03/11 /1R X-2TX

JU -EX3200-24T -DC-Shf

Slot 1 Por t 3 7

00.104 . 01 / P04

Port
10 00 base LX-01
C is co 76 09

0 0.202.03 /11 /??

From JU-EX3200 to STC ODF


JU-E X3200
Equipment
JU-EX3200-24T-DC

Site
HUTTAYN

Flr.Row.Bay/Pos

Slot

Port

00.104.01/P04

ULM

1000Base LX-01

Panel

Port

Cable Type
Duplex LC/FC
Single Mode

S TC ODF
Equipment
STC ODF

Site

Flr.Row.Bay/Pos

HUTTAYN

00.202.03

11

1Rx
2Tx

Equipment
Cisco 7609

Site

Flr.Row.Bay/Pos

Slot

Port

00.202.02/01

37

HUTTAYN

Note: Temporary feature for OOB Management

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Site Number

Page 30 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)
111-00-000

Cable Type
Duplex LC/FC
Single Mode

OOB EA

2.7

MASTER SHEET

OLTLocation

OLTVendor

BRASHostID

TrafficPE/BRAS

111-00-000

Fujitsu

111

Agg6-Hut-111-2 / Huttain

ProjectName

ProjectType

Location

OLTLocation

Region

District

OLT Plan

FTTH (GPON)

Hutten

111-00-000

Central

Riyadh

IP address
SubnetMask

ONTSubnet

IPrangeforONTs

VOIPGW
IPAddress

JUEX3200TDC
IPAddress

255.255.255.240

255.255.240.0

10.141.128.2 to 10.141.143.254

10.141.128.1

10.202.155.?

OLTGateway OLTIPAddress
10.202.155.14

10.202.155.1

IPrangeforSTBs
?

VLAN

HSIVLAN

VOIPVLAN

MGMVLAN

VODVLAN

MulticastVLAN

3045

2037

23

1501?

1500?

Uplink Information
PrimaryHost
Number

PrimaryEA
Type/Unit/IF
(EA7609)

111-00-000

Agg6-Hut-111-2

ODFLocationof
PrimaryPorts

BackupEA
Type/Unit/IF
(EA7609)

00/201.07/02/1RX-2TX

Agg6-Hut-111-2

Primary
Equipment PrimaryEA Primary PrimaryEA
Location
Slot
EABay
Port
TypeofIF
00/201.06/01

10 G.E XFP IR

Backup
BackupEA Backup BackupEA
Equipment
TypeofIF11
Slot
EABay
Port
Location
00/201.06/01

ODFLocationof
BackupPorts

10 G.E XFP SR 00/201.07/02/7RX-8TX

OOB Management Uplink Information

EA
Type/Unit/IF
HostNumber
(EA7609)
111-11-000

Agg6-Hut-111-1

Equipment
Location

EASlot

EABay

EAPort

TypeofIF

ODFLocation

00/202.02/01

37

G.E LX

00/202.03/11/1RX-2TX

SBC Information
Sitename
JVCode

IPaddress

Maather-108-00

10.200.0.11

6XC1

SubnetMask
255.255.255.252

Sitename2

JVCode

Khurais Rd 107-00

6XC0

Telephone Numbers
Directory
Number
(DN)Range
for
telephony
service
?

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

MASTER SHEET
Page 31 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

IPaddress
10.200.16.11

SubnetMask2
255.255.255.252

2.7.1 TEMPORARY OOB MANAGEMENT TABLE

100BaseMM Termination
Site Number : 111-00-000
Connections From

Connections To

MO-AXS1800-OLT
From Slot Name

From Plugin
Name

From Port Name

To Chassis
Location

To Slot Name

To Port Name

00.104.01/PO2

SLOT SYS-A

MO-AXS1800ASYSC

ENET-MGT1

JU-EX320024T-DC-Shf

SLOT ICP

PORT
1000BASET-01

00.104.01/PO2

SLOT SYS-B

MO-AXS1800ASYSC

ENET-MGT1

JU-EX320024T-DC-Shf

SLOT ICP

PORT
1000BASET-02

Project Name
Mop Type
Eng. Name
Site Name

JU-EX-3200-24T-DC

From Chassis
Location

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

MASTER SHEET
Page 32 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

2.8

ICMS

2.8.1 ICMS DIAGRAM ( Attachment )


2.8.2 ICMS TABLE ( Attachment )

2.9
Project Name
Mop Type
Eng. Name
Site Name

Power Connectivity Drawings

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

ICMS
Page 33 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Power Connectivity Drawings


Page 34 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

2.9.1 DCDP-DOUBLE-ROW-CB : 00.WALL.JN-4 (00.WALL.JN-4)

00.WALL.CISCO
DCDP Double Row Cabinet

A01 A02 A03 A04 A05 A06 A07 A08 A09 A10 C01 C02

ALARM

200A CB

25A CB

25A CB

50A CB

50A CB

25A CB

50A CB

50A CB

50A CB

50A CB

Main Fuse
+

SP
200A CB

200A CB

50A CB

ALARM

200A CB

50A CB

C03 C04 B01 B02 B03 B04 B05 B06 B07 B08 B09 B10

Main Fuse
A

50A CB

50A CB

50A CB

100A CB
50A CB

50A CB

50A CB

25A CB

B11 B12 B13 B14 B15 B16 B17 B18 B19 B20 B21 B22

25A CB

25A CB

25A CB

25A CB

50A CB

50A CB

50A CB

50A CB

50A CB

50A CB

50A CB

50A CB

50A CB

A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 A21 A22

50A CB

50A CB

Distribution Breaker (PWR-II)

25A CB

25A CB

50A CB

50A CB

50A CB

50A CB

100A CB

50A CB

50A CB

50A CB

Distribution Breaker (PWR-I)

2.9.2 DCDP-DOUBLE-ROW-CB : 00.WALL.JN-4 (00.WALL.JN-4)


Chassis Model Name
DCDP_DOUBLE_ROW_PNL

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

Location Code
00.WALL.CISCO

2052501
M-FTE-00001

Power Connectivity Drawings


Page 35 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

2.9.3 111-00-000 : DCDP-DOUBLE-ROW (Power)


Power Termination
Site Number : 111-00-000
Connections To
WA-2F-10TB-PDU

From Chassis
Location

From Slot
Name

From Plugin
Name

From Port
Name

To Chassis
Location

To Slot Name

To Plugin
Name

To Port Name

00.WALL.CIS
CO

SLOT A15

DCDP-CB100A

PORT FUSE

00.104.01/P
O1

SLOT TB02

WA-TB-2C

PORT IN

00.WALL.CIS
CO

SLOT B15

DCDP-CB100A

PORT FUSE

00.104.01/P
O1

SLOT TB05

WA-TB-2C

PORT IN

Project Name
Mop Type
Eng. Name
Site Name

Connections From
DCDP-DOUBLE-ROW

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Power Connectivity Drawings


Page 36 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

2.9.4 WA_2F_10TB_PDU : 00.104.01/PO1 (00.104.01) :


00.104.01/PO1

F01

TB: Termination Block

TB: Termination Block

TB: Termination Block

TB: Termination Block

TB: Termination Block

TB: Termination Block

10A : 10A Fuse

TB: Termination Block

TB: Termination Block

TB: Termination Block

10A : 10A Fuse

TB: Termination Block

Wago Power Distribution Unit

F02
TB01 TB02 TB03

TB04 TB05 TB06

TB07 TB08

TB09 TB10

2.9.5 WA_2F_10TB_PDU : 00.104.01/PO1 (00.104.01) :


00.104.01/PO1
Slots
SLOT F01
SLOT F02
SLOT TB01
SLOT TB02
SLOT TB03
SLOT TB04
SLOT TB05
SLOT TB06
SLOT TB07
SLOT TB08
SLOT TB09
SLOT TB10

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

WA-2F-10TB-PDU
Plugins
WA-FU-10A
WA-FU-10A
WA-TB-2C
WA-TB-2C
WA-TB-2C
WA-TB-2C
WA-TB-2C
WA-TB-2C
WA-TB-2C
WA-TB-2C
WA-TB-2C
WA-TB-2C

Descriptions
Wago Fuse 10A
Wago Fuse 10A
2-Conductor Termination Block
2-Conductor Termination Block
2-Conductor Termination Block
2-Conductor Termination Block
2-Conductor Termination Block
2-Conductor Termination Block
2-Conductor Termination Block
2-Conductor Termination Block
2-Conductor Termination Block
2-Conductor Termination Block

2052501
M-FTE-00001

Power Connectivity Drawings


Page 37 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

Power Termination
Site Number : 111-00-000

From Chassis
Location

Connections From
WA-2F-10TB-PDU
From Slot Name
From Plugin
Name

00.104.01/PO1

SLOT FU01

WA-FU-10A

PORT OUT

JU-EX320024T-DC-Shf

SLOT ICP

PORT DC-IN1

00.104.01/PO1

SLOT FU02

WA-FU-10A

PORT OUT

JU-EX320024T-DC-Shf

SLOT ICP

PORT DC-IN2

00.104.01/PO1

SLOT TB02

WA-TB-2C

PORT OUT

00.104.01/PO2

PORT PWR-A: 48 VDC

00.104.01/PO1

SLOT TB05

WA-TB-2C

PORT OUT

00.104.01/PO2

PORT PWR-B: 48 VDC

From Port Name

Connections To
JU-EX-3200-24T-DC, MO-AXS1800-OLT
To Chassis
To Slot Name
To Port Name
Location

Note : SLOT F01 and SLOT F02 temporary supply for OOB feature
( Juniper Switch ).

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Power Connectivity Drawings


Page 38 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

3 Approvals
3.1.1 Floor Plan

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Power Connectivity Drawings


Page 39 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

3.1.2 Extracted Floor Plan

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Power Connectivity Drawings


Page 40 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

3.1.3 Floor Space Approval

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Power Connectivity Drawings


Page 41 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

3.1.4 Power Approval

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Power Connectivity Drawings


Page 42 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

3.1.5 Permit to Work

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Power Connectivity Drawings


Page 43 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

4 Annex
4.1

Location Maps

4.1.1 Location Map for Site: 111-00-000 (Zoom 1)


X Location : 662680.000444617 Meters
Y Location : 2740939.99952692 Meters

111-00-000-HUTTAIN : CO

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Location Maps
Page 44 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

4.1.2 Location Map for Site: 111-00-000 (Zoom 2)


X Location : 662680.000444617 Meters
Y Location : 2740939.99952692 Meters

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

111-00-000-HUTTAIN : CO

2052501
M-FTE-00001

Location Maps
Page 45 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

4.1.3 Location Map for Site: 111-00-000 (Zoom 3)


X Location : 662680.000444617 Meters
Y Location : 2740939.99952692 Meters

Project Name
Mop Type
Eng. Name
Site Name

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

111-00-000-HUTTAIN : CO

2052501
M-FTE-00001

Location Maps
Page 46 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number

111-00-000

5 Glossary
GLOSSARY OF TERMS AND ABBREVIATIONS
The glossary lists the terms and abbreviations that apply specifically to this
document.
Note:

Project Name
Mop Type
Eng. Name
Site Name

The terms and abbreviations used in this document may have different
meanings in other contexts.

DCN

Data Communications Network

FDF

Fibre Distribution Frame

GPON

Gigabit-capable Passive Optical Network

IP

Internet Protocol

ODF

Optical Distribution Frame

OLT

Optical Line Termination

ONT

Optical Network Termination

PDU

Power Distribution Unit

RoHS

Restriction of Hazardous Substances - European directive

STC

Saudi Telecommunications Company

FTTX-GPON
Project Number
FTTH
Mop Number
Martin Betts\M.
Eng. ID
Calvelo\D. Lopez
QAIRAWAN/HUTEEN

2052501
M-FTE-00001

Location Maps
Page 47 of 47
10/19/2009
Remarks: MopGen Tools (R-1.5.5.8)

Site Number