DATA FOR IEEE-30 BUS TEST SYSTEM
The IEEE 30 bus test system is shown in figure A.1. The system data is taken
from references [3]. The generator cost and emission coefficients, load, shunt capacitor
data and transmission lines are provided in the Tables A.1, A.2, A.3 and A.4 respectively.
The cost coefficients of IEEE-30 bus system are slightly modified to incorporate nonsmooth fuel cost functions with ramp rate coefficients as given in Table A.5. The data is
on 100 MVA base. For all analysis on this system V imin, Vimax, imin and imax for bus i are
considered to be 0.9 p.u., 1.1 p.u., -45 degree and +45 degree respectively.
Table A.1. Generator Cost and Emission Coefficients
Gen P
Pimax
Qimin
Qimax
ai
bi c i
i
No. (MW) (MW) (MVAr) (MVAr)
min
i

1.
2.
3.
4.
5.
6.

50
20
15
10
10
12

200
80
50
35
30
40

-20
-15
-15
-10
-15

100
80
60
50
60

0.00375
0.01750
0.06250
0.00834
0.02500
0.02500

2.00
1.75
1.00
3.25
3.00
3.00

0
0
0
0
0
0

0.0126
0.0200
0.0270
0.0291
0.0290
0.0271

-1.1000
-0.1000
-0.0100
-0.0050
-0.0040
-0.0055

22.983
25.313
25.505
24.900
24.700
25.300

Table A.2. Load Bus Data


Bus
Load
Bus
Load
No. P (MW) Q (MVAr) No. P (MW) Q (MVAr)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

0.00
21.7
2.40
7.60
94.2
0.00
22.8
30.0
0.00
5.80
0.00
11.2
0.00
6.20
8.20

0.00
12.7
1.20
1.60
19.0
0.00
10.9
30.0
0.00
2.00
0.00
7.50
0.00
1.60
2.50

16
17
18
19
20
21
22
23
24
25
26
27
28
29
30

3.50
9.00
3.20
9.50
2.20
17.5
0.00
3.20
8.70
0.00
3.50
0.00
0.00
2.40
10.6

Table A.3. Shunt Capacitor Data


Bus No. Susceptance
10
24

19
4

1.80
5.80
0.90
3.40
0.70
11.2
0.00
1.60
6.70
0.00
2.30
0.00
0.00
0.90
1.90

118

2
G

1
14
3

13
G

15

4
12

16

30

18
23

20
5
G

21 19

10

29

24
27

22

11

25
28

G
26
8
G
Fig. A.1. One line diagram - IEEE-30 Bus System

119

Table A.4. Transmission Line Data


Series Impedance (p.u)
Line
No.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.

From To
Bus Bus
1
1
2
3
2
2
4
5
6
6
6
6
9
9
4
12
12
12
12
14
16
15
18
19
10
10
10
10
21
15
22
23
24
25
25
28
27
27
29
8
6

2
3
4
4
5
6
6
7
7
8
9
10
11
10
12
13
14
15
16
15
17
18
19
20
20
17
21
22
22
23
24
24
25
26
27
27
29
30
30
28
28

0.01920
0.04520
0.05700
0.01320
0.04720
0.05810
0.01190
0.04600
0.02670
0.01200
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.12310
0.06620
0.09450
0.22100
0.08240
0.10700
0.06390
0.03400
0.09360
0.03240
0.03480
0.07270
0.01160
0.10000
0.11500
0.13200
0.18850
0.25440
0.10930
0.00000
0.21980
0.32020
0.23990
0.06360
0.01690

0.05750
0.18520
0.17370
0.03790
0.19830
0.17630
0.04140
0.11600
0.08200
0.04200
0.20800
0.55600
0.20800
0.11000
0.25600
0.14000
0.25590
0.13040
0.19870
0.19970
0.19320
0.21850
0.12920
0.06800
0.20900
0.08450
0.07490
0.14990
0.02360
0.20200
0.17900
0.27000
0.32920
0.38000
0.20870
0.36900
0.41530
0.60270
0.45330
0.20000
0.05990

Half Line
Charging
susceptance
(p.u.)

Tap
Settin
g

MVA
Rating

Annual
Cost
(K$/year)

0.02640
0.02040
0.01840
0.00420
0.02090
0.01870
0.00450
0.01020
0.00850
0.00450
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.00000
0.02140
0.00650

1.0155
0.9629
1.0129
0.9581
-

130
130
65
130
130
65
90
70
130
32
65
32
65
65
65
65
32
32
32
16
16
16
16
32
32
32
32
32
32
16
16
16
16
16
16
65
16
16
16
32
32

216.6125
307.2875
509.9500
700.0000
721.5250
168.1750
474.3000
62.0000
130.2000
104.6250
306.9000
20.9250
83.7000
927.6750
554.1250
15.1125
30.2250
97.6500
179.0250
124.7750
146.4750
80.6000
235.6000
186.0000
117.8000
167.4000
160.4250
195.3000
166.2375
100.7500
40.3000
65.1000
210.8000
204.6000
83.7000
223.2000
160.4250
90.6750
216.6125
54.2500
210.8000

120

Table A.5. Modified Generating units coefficients with Ramp rate limits
Gen.
No.
1

2
3
4
5
6

Pgimin

Pgimax

ai

50
63.750
82.875
93.750
157.500
176.625
25
43
20
15
13
14

63.750
82.875
93.750
157.500
176.625
200
43
63
49
30
28
35

0
0
0
0
0
0
0.010
0.020
0.070
0.090
0.025
0.025

bi

ci

3.060
87.5
0.000
0.0
8.920 -457
3.700
32
0.000
0
7.700 -745
0.300
35
0.600
60
0.095
45
0.025
30
3.000
0
3.000
0

di

ei

0
0
0
0
0
0
0
0
40
30
0
0

0
0
0
0
0
0
0
0
0.08
0.09
0
0

0
282
0
0
615
0
0
0
0
0
0
0

P0gi URi DRi


135 65

85

65

12

22

35
25
20
30

12
08
06
08

15
16
09
16