Air Standard Cycle - Design Conditions

Fuel
1.17310 kg/s
659.087 T2 ( K)
385.937 T2 ( C)
16.208 P2 (bar)

Heat Rate (kJ/kW-hr)


9684.688

1523.15 T3 ( K)
1250.00 T3 ( C)
15.560 P3 (bar)

58666.8826283503 Q (kJ/s)

Gas (Air + Fuel)


51.1731
872.171
1.023

Air Feed
50
288.15
15
1.013

Stack

kg/s
T1 ( K)
T1 ( K)
P1 (bar)

1523.15 T4 ( K)
1250 T4 ( C)
15.560 P4 (bar)

-19400.000
W_AC (kJ/s)

41207.701
NET

51.1731
872.171
599.021
1.023

51.1731 kg/s
#MACRO? T7( K)
1.013 P7 (bar)

#MACRO?
485.550
20.000
#MACRO? kg/s
388.890 T8( K)

Economizer

Evaporator

20.000 P8 (bar)

#MACRO?

Variables

Physical

Fair (kg/s) = 50
nAC = 0.89

a =

T3 (K) = 1523.15

1.38
1.046

3600 s = 1 hr
1kW = 1kJ/s

3600
1

g =

1.31

1000 W = kW

1000

Cp,g (kJ/kg-K) =

1.237

Tref (K) =

298.15

CH4(kJ/kg) =

50010

nGT = no GT here
nPT = 0.9
h

(485.55K) =

v,sat

h (470.55K, 20) =
hl(388.89K, 20) =
l

Units Conversion

Cp,a (kJ/kg-K) =

P2 (bar) = 16.208

Tpinch ( K) = 10
Tapproach ( K) = 10

23840.539

Sheet Functions

MW H20

P(bar) must be P(Mpa)

#MACRO? kJ/kg

#MACRO? kJ/kg

#MACRO? kJ/kg
#MACRO? kJ/kg

#MACRO? kJ/kg
#MACRO? kJ/kg

Material and Energy Balances


Temperatures (Real)

Isentropic_Temps

Pressures

Air_Fuel_Steam

T0 (K) = 288.15
T1 (K) = 288.15

P0 (bar) = 1.013
P1 (bar) = 1.013

T2 (K) = 659.09
T3 (K) = 1523.15

P2 (bar) = 16.208
P3 (bar) = 15.560

1
Ffuel (kg/s) = 1.173103032

T4 (K) = 1523.15
T5 (K) = 872.1710748

P4 (bar) = 15.560
P5 (bar) = 1.023

Fair + Ffuel (kg/s) = 51.17310303

T6 (K) = 872.1710748
T7p(K) = 495.55
T7 (K) = #MACRO?
T8 (K) = 388.89
T8p (K) = 475.55

T5_Iso (K) = 799.840083

P6 (bar) = 1.023
P7p (bar) = 1.018
P7 (bar) = 1.013
P8 (bar) = 20.000
P8p (bar) = 20.000

nCC =

Fsteam (kg/s) =

#MACRO?

Fwater (kg/s) =

#MACRO?

T9 (K) = 485.55

P9 (bar) = 20.000

Heat

Work

QCC (kJ/s) = 58666.883


QLoss (kJ/s) = 0.000

WAC_Actual (kJ/s) = -19399.9997


PowerAC_Actual (kW) = -19399.9997

Efficiency = 0.702401401
WPT_Actual (kJ/s) = 41207.7006
Transferred QEvap (kJ/s) = 23840.5390

W_PT_Isentropic (kJ/s) = 45786.334

Transferred QEcon (kJ/s) = #MACRO?

PowerPT_Actual (kW) = 41207.700563411


Power_Net Output (kW) = 21807.7008398556

Parameters Needed for Off-Design Performance Calculations


Value
0.5
Choked Turb In
(FT )/P
128.3548929537
T
Turbine Exit T
872.1710747884
5
Fd

50
nAC =

Net Powerd

0.89
21807.7008398556

as (Air + Fuel)
kg/s
T5 ( K)
P5 (bar)
Generator with 98% efficiency
21.371547 MW
W_PT (kJ/s)
21.8077 MW

kg/s
T6( K)
T6( C)
P6 (bar)

kg/s
T9( K)
P9 (bar)

18.0153

blue

variable

plum
teal

constant
calculated