You are on page 1of 1

Sample calculation :

Sample calculation :
Using Ferric Chloride, FeCl3
Volume of concentration = 2 ml

Using Aluminium Sulphate, Al2(SO4)3

Volume of water sample = 500 ml

Volume of concentration = 12 ml
Volume of water sample = 500 ml

Coagulant Concentration :
=

volume of concentration
x 10 g
1000ml

Coagulant Concentration :

2 ml
x 10 g
1000 ml

volume of concentration
x 10 g
1000ml

12 ml
x 10 g
1000 ml

= 0.02 g

= 0.12 g
Dosage :
=

Coagulant concentration
500 ml

Dosage :

0.02 g
500 ml

Coagulant concentration
500 ml

0.12 g
500 ml

= 40 mg / L

= 240 mg / L
Turbidity Removal :
=

InitialFinal
x 100
Initial

Turbidity Removal :

25.624.6
x 100
25.6

InitialFinal
x 100
Initial

33.533.4
x 100
33.5

= 3.91 %

= 0.3 %