You are on page 1of 8

PRODUCT CATALOGUE

PROFLEX
Thermal Insulation

CFC free HCFC free


Zero Ozone Depletion Potential (ODP)

Taking care
of energy and
Environment

PROFLEX

Proex polyolen foam thermal insulation for Air-Conditioning, Refrigeration,


Roof, Acoustic & Plumbing System related to the HVAC&R Industry.
Proex Insulation developed after continuous and understanding the needs of the changing demands of
the new generation equipment solution.

Proex is a chemically cross-linked closed-cell


polyolen foam thermal insulation
What does cross-linked means?

A method of making the cell structure stronger-preventing the


trapped gas bubbles from bursting. This means that Proex
has superior strength to other non cross-linked and Rubber
material

How can Proex Insulation Benet the


Environment

With todays increasing consumer awareness of protecting


the environment. Proex has been Engineered to provide
high quality insulation, Proex is an insulating material
produced without the use of CFC, HCFC, with zero ozone
depletion potential (ODP) which mean Environment friendly
product.

Proex Energy Saving, Money


Saving Insulation

Energy is the single largest operating expenses for commercial building and factories each year
Did you know that about 44% of your total utility bill pays for
heating and cooling your Home, Commercial Buildings and
Factories

We offer Proex specically for the insulation requirements of


various industries, with a sole purpose of improving the
energy efciency, and thereby helping in conserving energy.

Excellent re-retardant
Proex contains various ame blocking and smoking reducing
elements and therefore smoke density is very low when a re
occurs. Proex doesnt melt when it caches re, not to cause
spark it has self re extinguishing material and cannot be the
root cause of combustion

www.alsafagroup.net

E-mail: info.proex@alsafagroup.net

Duct insulation
Proex Duct Insulation

The sustainable benets of using proex insulation


are numerous, including

Proex is chemically cross-linked closed-cell polyolen thermal insulation is a light weight with excellent
thermal insulation properties, excellent compressive
and condensation control, excellent durability and
exibility ,weather chemical resistant, Non hazard,
Non irritant, safe and odorless ,will not allow bacterial
growth, Proex is Fiber free, free of cadmium, lead
stabilizers, tin organic substances and other heavy
metals, Proex is un affected by most acids, alkalis,
alcohols, detergents and petrochemicals. Environment friendly and energy saving characteristics.

Easy and simple construction

The exceptional exibility of Proex is great help to


the installer, Proex is supplied in any thickness, any
size of Rolls and sheets to minimize wastage installation time reduced further when supplied with aluminum foil and self adhesive which is more popular in
duct insulation application. Proex duct insulation
material can be easily applied to the metal ducts
through a process of pre-adhesion, Proex doesnt
emit dust or ber particles so protective clothing not
required during installation.

Applications

General duct work insulation for construction HVAC


system (building/factories) it is also suitable for
square and round duct construction

Product range

Continuous sheet

Standard with Alum foil & self adhesive

Wall thickness mm
3
4
5
6
9
13
15
19
25
32
50

www.alsafagroup.net

M /roll
100
100
100
100
60
20
20
15
15
10
2

Width 1.2, 1.06


Contact our sales department
for length cutting

Note: Installing insulation properly is important because gaps, voids, compressions,


and moisture reduce the effectiveness of
insulation and allow unconditioned air to
enter your home

E-mail: info.proex@alsafagroup.net

Pipe Insulation
Proex Pipe Insulation

Proex Sleeves chemically cross-lined closed cell


polyolen foam for all piping work except high
steam line
Proex manufacture in pre formed pipe section
comprises two meter long section

Proex insulation faced with factory applied


reinforced aluminum foil as a vapor barrier jacket.
Proex pipe insulation available in full range of pipe
diameter and used on mild steel, stainless steel,
copper pipe, and plastic pipe work

Applications:

The following services shall be insulated:


Chilled water pipe work
Condensate pipe work
Hot water pipe work and Cold water pipe work
Drain pipe work and Refrigeration line and others.
Length: Production by order possible
pipe dia can be make up to 20

Dimension
Designation of mould (1)
Polyvinyl
Steel Pipe
Chloride pipe
A
B
10
15
20
25
32
40
50
65
80
90
100
125
150

3/8
1.2
3/4
1
1 1/ 4
1 1/2
2
2 1/2
3
3 1/2
4
5
6

13
16
20
25
30
40
50
65
75
100
125
150

Copper
Pipe
6.35
9.52
12.70
15.88
19.05
22.22
25.40
28.58
31.75
34.92
38.10
41.28
53-98
66-88
79-88
104-78
-

Inside
Tolerance
diameter of on Inside
diameter of
moud
mould
7
10
13
16
18
20
22
26
8
32
35
38
43
49
54
61
67
77
80
90
102
105
115
140
166

www.alsafagroup.net

+3
0

+4
0

+5
0

+6
0

Thickness

5
7.5
10
15
20
5
7.5
10
15
20
25
30
10
50

10
15
20
25
30
40
50

Tolerance
on thickness

Length

Tolerance
on length

In case of
thickness of
5 and 7.5
+15
-1.0
In case of
thickness of
10 and 15
+2.0
-1.5
In case of
thickness of
20 or over.
+3.0
-2.0

E-mail: info.proex@alsafagroup.net

2000

+50
0

Other construction Meterial

Proex Sound Solution

Noise pollution is an often overlooked environment


problem, disturbance from un wanted sound can
effect human health and performance, Noise
radiating from piping and ductwork can be a
serious problem in modern building construction.
Turbulent ow piping noise can be caused by water
or other liquids passing through elbows, vales or
other transition pieces. Duct noise is caused by air
owing past obstructions or branches which results
in vibration of the metal duct work this vibration
then radiates noise into the building.

Proex developed a most effective treatment method for the control of piping and
duct breakout noise is to wrap the piping
and ducting with proex acoustic lagging.

Current building construction material


cause piping and ducting work noise to be
more of a concern today than in the past.

Proex Internal Insulation for metal


ductwork (Duct lining)
Metal duct work often requires acoustic insulation
to prevent air-borne noise from inside the duct

Noise Emerges into the building through grills and


other transition pieces
Proex duct lining design primarily to provide
acoustic insulation to the duct system

Due to the excellent thermal and acoustic properties


Proex can breakout noise transmission; also
improve comfort, and thermal performance

Application: Internal surfaces of the metal duct for


air-conditioning or ventilation ductwork

www.alsafagroup.net

E-mail: info.proex@alsafagroup.net

Accessories

Aluminium Tape 2-3

Foam tapes and gaskets


3mm x 12mm x10m

3mm x 20mm x 10m


3mm x 25mm x 10m

Double side self adhesive tape


3mm x 12mm x10m

3mm x 105mm x 25mm


6mm x 25mm x 15m
Proex

Proex Adhesive

Proex Adhesive has been specially formulated for proex


products and guarantees a homogeneous and reliable joints its seams

Roof Insulation

Proex roof insulation provides high performance thermal insulation and also can be used as a vapor
barrier, Proex roof insulation can help to improve indoor temperature and increase energy saving,
the energy saving properties of insulation keeps building warm in winter and cold in summer.

Installation

It is fast to install and perform for the life of building without a requirement of maintenance
Step 1 Roll over purlin / roof and secure

Step 2 mount roof sheets on top of the insulation


www.alsafagroup.net

E-mail: info.proex@alsafagroup.net

Proex Technical properties

Physical properties

Raw material
Cellular Structure
Closed-Cell Content
Density
Thermal Conductivity
Water Effect
Water Vapor Permeability
Amount of Water absorption( After 240 Hr.)
Water Vapor Transmission

Polyolen Resin
Cross-Linked Closed-Cell
90%
30 to 50 kg/m ASTM C 518l
0.28w /( m.k ) @ 25c 0.040 w/(m.k) @ 35

Fire Resistant
Temperature Range
O dour
Color
Vibration absorption
Pollution/ Toxic
Spread of ame
Smoke developed index
Anti-fungal

Class 0 BS 76 part 6,Class 1 BS part 7


From -80 C - + 120 C
Neutral
Grey/Black
Excellent
Non
0
0-1
Strong
35 db (A) to the frequency F500H2 European
Standard EN20140-10
%90 Both direction
Almost no shrinkage
90%
Excellent
High resistant

Noise reduction
Tensile strength
Shrinkage
Elongation
Chemical resistant
Resistant to permanent deformation

Bonding / Lamination
Adhesive
Cutting
Thermo -forming

0.00 ASTM E90-00


Ng/pasm 0.00E00+

Skiving
Tubing
Environment -friendly

Aluminum foil PET 12 micron/AL 7


micron/LLDPE 20 MICRON (39 micron)
Heat treated acrylic copolymer applied to
foam surface
Easily cut or die-cut to any desired size or
shape
All grade can be vacuum formed or
compression molded with heat
Foam can be easily skived to desired
thickness. Convolution shaping is also
possible with proper equipment
Tubing is available with multiple dimensional
combination of inside diameter,thickness,and
length
Generates negligible hazardous gas during
combustion. It is non toxic and contain no
CFCs and HCFCs 100% recyclable

Stable Low Thermal conductivity

Proex is closed-cell foam. It will not absorb


moisture or vapor this mean the thermal
conductivity remains constant throughout the life
time of foam. Other types of open cell and rubber
insulation materials thermal conductivity will not
remain constant as it will increased over a period
of time due to the absorption of moisture into the
structure of the material.

Water vapor permeability (factor) permeation ratio


tested of water after 240/hr 0.00% ASTM E 96.

Proex

Proex insulation has a very low thermal


conductivity value 0.040 w/mk at mean
temperature 35C (ASTM 518)

Condensation Control
Vapor diffusion into the insulation material is one of
the major causes of condensation. The technology
is to laminate Proex foam with aluminum foil as a
vapor barrier itself and it is effective dew formation
caused by a drastic changes in temperature.
proex with more than 90% of closed-cell and
independent air bubble structure it prevent dew
forming.

www.alsafagroup.net

E-mail: info.proex@alsafagroup.net

Project Reference

Marina Lusail Twin Tower

Air Port Office Building

Dukhan Tower

Energy City Mall Lusail

Office Building

Distributor / Agent

PROFLEX

Insulation Industries WLL


P.O.BOX:22384,DOHA, QATAR

TEL: +974 44210167 FAX: +974 44363728


E-mail: info.proex@alsafagroup.net

22384
+974-44210167
+974-44363728

www.alsafagroup.net

Copy right Proex Insulation Industries. Proex is a registered trade mark of proex Insulation Industries

You might also like