You are on page 1of 5

CREAT BSC COMMAND IN MGW

BSC SPC = D'02000, MSS SPC = D'12104, ET NUMBER , POOL, TIMESLOT FOR SIGNALLING

Change the speed of optical ET not for Electrical ET


ZYAF:ET,<OPTICAL ET>:16;

Set the nbr WHICH ARE USING FORO SIGNALLING


ZR2S:ET,128:NBR=1;

CREAT ATER ON ET
ZR2C:ET,128:CPPOL=23,APCM=11000,TCPCM=1;

1. Creating signalling link (WHICH E1&ISU R U USING)


ZNCN:20:128-16,64:ISU,1:0:;

2. Creating signalling link set (TDM BASED)


ZNSC:NA1,D'02000,TEBSC:20,0:;

3.Creating signalling route set


ZNRC:NA1,D'02000,TEBSC,1,,:,,,0:;

4. Creating Additional OPC (AOPC OF MSS)


ZNRB:NA1,D'02000:AOPC=D'12104:;

5.Allowing activation of signalling links


ZNLA:20:;

6. Changing Signalling Link State


ZNLC:20,ACT:;

7. Allowing Activation Of Signalling Route


ZNVA:NA1,D'02000::;

8. Changing Signalling Route State


ZNVC:NA1,D'02000::ACT:;

9. Defining SCCP For Signalling Point


ZNFD:NA1,D'02000,1:FE,BSSAP,1,N:::::;

10. Changing SCCP State


ZNGC:NA1,D'02000:ACT:;

11. Changing subsystem state


ZNHC:NA1,D'02000:FE:ACT:;

12. Changing subsystem state


ZNHC:NA1,D'02000:FE:ACT:;

13. Create Circuit Group


ZRCC:CGR=900,TYPE=SPE,NCGR=TESTB1::;

14. Add Circuits to Circuit Group


ZRCA:CGR=900:CRCT=128-1&&-15:;

15. Add circuit Group to Virtual MGW


ZJVE:VID=0,:CGR=900,:;

16. Change internal circuits state


ZCIM:CRCT=128-1&&-15:WO:;

17. Change Circuit group states


ZCIM:CGR=900:WO:;

18. Interrogate Circuits Info


ZCII:CGR=900:;

19. INTERROGATE CGR AND Circuits


ZRCI:SEA=5:CRCT=131-1&&-31:;
CREAT BSC IN MSS

BSC SPC = D'02000 , LAC = 8030 AND MGW SPC = D'12106

1. Define Location Area


ZELC:NAME=TEBSC,LAC=8030,:::;

2. Create BSC
ZEDC:NAME=TEBSC,NO=30:::;

3. Create Signalling Point Code of BSC


ZEDL:NO=30:NA1,D'02000:;

4. Creating signalling route set


ZNRC:NA1,D'02000,TEBSC,1,,:NA1,D'12106,MGWKP2,7::::;

5. Allowing Activation Of Signalling Route


ZNVA:NA1,D'02000:NA1,D'12106:;

6. Changing Signalling Route State


ZNVC:NA1,D'02000:NA1,D'12106:ACT:;

7. Defining SCCP For Bsc Signalling Point


ZNFD:NA1,D'02000,1::::::;

8. Add subsystem to BSC signalling point code


ZNFB:NA1,D'02000:FE,BSSAP,1,N:;

9. Activate SCCP state for BSC


ZNGC:NA1,D'02000:ACT:;

10. Activate Subsystem state for BSC


ZNHC:NA1,D'02000:FE:ACT:;

11. Create Circuit group according to A interface (USE LSI FRM EXISTING DATA)
ZRCC:TYPE=ECCS,NCGR=TEBSC,CGR=900:DIR=OUT,NET=NA1,SPC=D'02000,LSI=DISU4,UPART=5:MGW=REALMGW:;

12. Add circuits to the Circuit Group


ZRCA:NCGR=TEBSC:TERMID=10-1&&15&10-17&&31,:CCSPCM=0;

13. Create Internal circuit group and attach BSC circuit group
ZRRC:INT,GSW:ROU=900,NCGR=TEBSC1;

14. Define Routes of Circuit pool


ZEDR:NO=30:7,900,:;

15. Unlock BSC (AFTER UNLOCK BTS)


ZEDS:NO=30:U:;
CREAT BTS IN MSS

CLN = 919932 AND NO AND CI = 12711

1. Configure Relationship between BTS and Location Area


ZEPC:TYPE=BTS,NAME=TEBTS1,NO=12711:LAC=8030,CI=1:;

2. Modify BTS service area parameters


ZEPR:TYPE=BTS,NO=1::CLN=919932,TON=INT,NPI=ISDN,PRES=A,INN=N:;

3. Configure Location Area BTS and BSC relation


ZEPB:NO=1:BSCNO=30:LAC=8030:;

4. Unlock BTS
ZEPS:NO=1:U:;

02000,LSI=DISU4,UPART=5:MGW=REALMGW:;

You might also like