You are on page 1of 7

ART960046.book Page 172 Mardi, 9.

mai 2006 11:25 11

Type 1 coordination
(IEC 60947-4-1)

Complementary
technical information

DB105243

Merlin Gerin NS80 circuit breakers,


Telemecanique contactors and thermal relays
Direct-on-line starting
Reverser
"Iq" breaking performance: equal to the breaking capacity of the circuit breaker alone.
Starting: normal
LR2 class 10 A, LR9 class 10.

Motors
220/230 V
P
I
(kW) (A)

380 V
P
(kW)
0.37
0.55
0.75

440 V (1)
P
I
(kW) (A)
0.37
1
0.55
1.4
0.75
1.7
1.1
2.4

I
(A)
1.2
1.6
3

415 V
P
(kW)
0.37
0.55
0.75

I
(A)
1.1
1.5
1.8

2.8
3.7
5
6.6
8.5

1.1
1.5
2.2
3
4

2.5
3.5
4.8
6.5
8.2

1.5
2.2
3
4

500/525 V
P
I
(kW) (A)
0.55
1.2
0.75
1.5

660/690 V
P
I
(kW) (A)
0.75
1.2
1
1.5

1.1
1.5

2
2.6

3.1
4.5
5.8
7.9

3
4
5.5

5
6.5
9

1.5
2.2
3
4
5.5

2
2.8
3.8
4.9
6.6

7.5

8.9

10

11.5

15
18.5

17
21.3

0.37

1.8

0.55

2.8

1.1
1.5
2.2

4.4
6.1
8.7

1.1
1.5
2.2
3
4

3
4

11.5
14.5

5.5
7.5

11.5
15.5

5.5
7.5
9

11
14
17

5.5
7.5
9

10.4
13.7
16.9

7.5
9
10

12
14
15

5.5

20

11

22

11

21

11

20.1

11

18.4

7.5

28

15

30

15

28

15

26.5

11

39

18.5
22

37
44

22
25

40
47

22

39

15

52

30

51.5

18.5

64

30

59

30
37

55
66

37

22

75

37

72

45

80

45

(1) Valid for 480 V NEMA.


(2) Reversers: replace LC1 by LC2.

172

18.5
22

28.5
33

30

34.6

30

45

33

39

37

42

64

37

55
45

49

76

55

80
55
75

60
80

Circuit breakers

Contactors (2)

Thermal relays

Type

Type

Type

LC1-D09
LC1-D09
LC1-D09
LC1-D09
LC1-D09
LC1-D09
LC1-D09
LC1-D09
LC1-D09
LC1-D12
LC1-D12
LC1-D18
LC1-D18
LC1-D18
LC1-D25
LC1-D25
LC1-D32
LC1-D32
LC1-D40
LC1-D40
LC1-D50
LC1-D50
LC1-D65
LC1-D65
LC1-D65
LC1-D80
LC1-D80
LC1-D115
LC1-F115

LRD-06
LRD-06
LRD-07
LRD-07
LRD-08
LRD-08
LRD-10
LRD-12
LRD-14
LRD-14
LRD-16
LRD-21
LRD-21
LRD-16
LRD-22
LRD-21
LRD-22
LR2-D33 53
LR2-D33 55
LR2-D33 57
LR2-D33 57
LR2-D33 59
LR2-D33 57
LR2-D33 59
LR2-D33 61
LR2-D33 57
LR2-D33 63
LR9-D53 63
LR9-F53 63

NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA

Rating
(A)
2.5
2.5
2.5
2.5
6.3
6.3
6.3
12.5
12.5
12.5
12.5
25
25
25
25
25
50
50
50
50
50
50
50
80
80
80
80
80

Irth
(A)
1/1.6
1/1.6
1.6/2.5
1.6/2.5
2.5/4
2.5/4
4/6
5.5/8
7/10
7/10
9/13
12/18
12/18
9/13
17/25
12/18
17/25
23/32
30/40
37/50
37/50
48/65
37/50
48/65
55/70
37/50
63/80
48/80

ART960046.book Page 173 Mardi, 9. mai 2006 11:25 11

Type 1 coordination
(IEC 60947-4-1)

Complementary
technical information

DB105243

Merlin Gerin NS100 circuit breakers,


Telemecanique contactors and thermal relays
Direct-on-line starting
Reverser
"Iq" breaking performance: equal to the breaking capacity of the circuit breaker alone.
Starting: normal
LR2 class 10 A, LR9 class 10.
Motors
220/230 V
P
I
(kW) (A)

440 V (1)
P
I
(kW) (A)
0.37 1
0.55 1.4
0.75 1.7
1.1
2.4

I
(A)
1.2
1.6
2

415 V
P
(kW)
0.37
0.55
0.75

I
(A)
1.1
1.5
1.8

2.8
3.7
5
6.6
8.5

1.1
1.5
2.2
3
4

2.5
3.5
4.8
6.5
8.2

1.5
2.2
3
4

500/525 V
P
I
(kW) (A)
0.55 1.2
0.75 1.5

660/690 V
P
I
(kW) (A)
0.75 1.2
1
1.5

1.1
1.5

2
2.6

3.1
4.5
5.8
7.9

3
4
5.5

5
6.5
9

1.5
2.2
3
4
5.5

2
2.8
3.8
4.9
6.6

7.5

8.9

10

11.5

15
18.5

17
21.3

30

34.6

0.37

1.8

0.55

2.8

1.1
1.5
2.2

4.4
6.1
8.7

1.1
1.5
2.2
3
4

3
4

11.5
14.5

5.5
7.5

11.5
15.5

5.5
7.5
9

11
14
17

5.5
7.5
9

10.4
13.7
16.9

7.5
9
10

12
14
15

5.5

20

11

22

11

21

11

20.1

11

18.4

7.5

11

15
18.5

28

39

52
64

15

30

15

28

18.5

37

22

40

22

44

25

47

30

59

30

55

15

22

26.5

18.5
22

39
30

30
37

28.5
33

51.5
64

37

45

22

75

37

72

25

85

45

85

100

37
45

55

72
80

100

45

55

76

96

55

Type

Type

Type

NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA

Rating
(A)
2.5
2.5
2.5
2.5
6.3
6.3
6.3
12.5
12.5
12.5
12.5
25
25
25
25
25
50
50
50

LC1-D09
LC1-D09
LC1-D09
LC1-D09
LC1-D09
LC1-D09
LC1-D09
LC1-D09
LC1-D09
LC1-D12
LC1-D12
LC1-D18
LC1-D18
LC1-D18
LC1-D25
LC1-D25
LC1-D32
LC1-D32
LC1-D40

NS100N/SX/H/L-MA

50

LC1-D40

LRD-06
LRD-06
LRD-07
LRD-07
LRD-08
LRD-08
LRD-10
LRD-12
LRD-14
LRD-14
LRD-16
LRD-21
LRD-21
LRD-16
LRD-22
LRD-21
LRD-22
LR2-D33 53
LR2-D33 55
LR9-D53 57
LR2-D33 57
LR9-D53 57
LR2-D33 57
LR9-D53 57
LR2-D33 57
LR9-D53 57
LR2-D33 59
LR9-D53 63
LR2-D33 57
LR9-D53 63
LR2-D33 63
LR9-D53 63
LR2-D33 65
LR9-D53 67
LR9-D53 63
LR9-F53 63
LR9-D53 67 60/100
LR9-F53 67

33

39

NS100N/SX/H/L-MA

50

LC1-D50

37

42

NS100N/SX/H/L-MA

50

LC1-D65

NS100N/SX/H/L-MA

100

LC1-D65

NS100N/SX/H/L-MA

100

LC1-D80

NS100N/SX/H/L-MA

100

LC1-D80

NS100N/SX/H/L-MA

100

LC1-D95
LC1-D115
LC1-F115
LC1-D115
LC1-F115

55
45

30

Contact.(2) Thermal relays

Circuit breakers
380 V
P
(kW)
0.37
0.55
0.75

49

80

55

60

NS100N/SX/H/L-MA

100

75

80

NS100N/SX/H/L-MA

100

Irth
(A)
1/1.6
1/1.6
1.6/2.5
1.6/2.5
2.5/4
2.5/4
4/6
5.5/8
7/10
7/10
9/13
12/18
12/18
9/13
17/25
12/18
17/25
23/32
30/40
30/50
37/50
30/50
37/50
30/50
37/50
30/50
48/65
48/80
37/50
48/80
63/80
48/80
80/93
60/100
48/80

(1) Valid for 480 V NEMA.


(2) Reversers: replace LC1 by LC2.

173

ART960046.book Page 174 Mardi, 9. mai 2006 11:25 11

Type 1 coordination
(IEC 60947-4-1)

Complementary
technical information

DB105245

Merlin Gerin NS160 to NS1250 and C1251 circuit breakers,


Telemecanique contactors and thermal relays
Direct-on-line starting
Reverser
"Iq" breaking performance: equal to the breaking capacity of the circuit breaker alone.
Starting: normal
class 10.
Motors
220/230 V
P
I
(kW) (A)
37
125
45
150
55
180

I
(A)
105
140
170

110

210

415 V
P
I
(kW) (A)
75
135

440 V (1)
P
I
(kW) (A)
75
124

90

160

110

200

90
110
132

75
90

250
312

132
160

250
300

132
160

230
270

160

110

360

200

380

220

380

220

150

480

220
250

420
480

250
250

156
180
215

256

360

500/525 V
P
I
(kW) (A)
75
110
90
130
110 156

660/690 V
P
I
(kW) (A)
90
100
110 120

132

190

132
160

140
175

160
200

228
281

200
220

220
240

220

310
250
335

270
335

375
450

400
480

401

430

315
335
300

480

160

520

300

570

300

510

335

540

200

630

335

630

335

580

375

590

220

700

375

700

375

650

400

650

400

750

400

690

450

720

355
375
400
450

445
460

500
530
570
630

500
560
250

300

800

450

800

450

750

500
560

700
760

500

900

500

830

800 600
900
960 670
1080 750

830

500
560
920 600
1000 670

560 1000 560


600 1100 600
(1) Valid for 480 V NEMA.
(2) Reversers: replace LC1 by LC2.

174

970

Contactors (2)

Circuit breakers
380 V
P
(kW)
55
75
90

920
1020

530
580

Type

Rating Type

NS160N/SX/H/L MA

(A)
150

NS 250N/SX/H/L MA

Thermal relays
Type

220

LC1D-150
LC1F-150
LC1F-185

Irth
(A)
LR9-D53 69 90/150
LR9-F53 69 100/160
LR9-F53 71 132/220

NS 250N/SX/H/L MA
NS 250N/SX/H/L MA

220
220

LC1F-225
LC1F-265

LR9-F53 71 132/220
LR9-F53 71 132/220

NS400N/H/L MA
NS400N/H/L MA

320
320

LC1F-265
LC1F-330

LR9-F73 75 200/330
LR9-F73 75 200/330

NS630N/H/L MA
NS630N/H/L MA
NS630N/H/L MA
NS630N/H/L MA
NS630bN/H/L Micrologic 5.0
NS630N/H/L MA
NS630bN/H/L Micrologic 5.0
NS630bN/H/L Micrologic 5.0
C801N/H STR35ME
C1001L STR35ME
NS630bN/H/L Micrologic 5.0
C801N/H STR35ME
C1001L STR35ME
NS800N/H/L Micrologic 5.0
C801N/H STR35ME
C1001L STR35ME
NS800N/H/L Micrologic 5.0
C801N/H STR35ME
C1001L STR35ME
NS630bN/H/L Micrologic 5.0
C801N/H STR35ME
C1001L STR35ME
NS800N/H/L Micrologic 5.0
NS1000N/H/L Micrologic 5.0
C1001N/H STR35ME
NS1000N/H/L Micrologic 5.0
C1001N/H STR35ME
NS1250N/H Micrologic 5.0
C1251N/H STR35ME

500
500
500
500
630
500
630
630
800
1000
630
800
1000
800
800
1000
800
800
1000
630
800
1000
800
1000
1000
1000
1000
1250
1250

LC1F-400
LC1F-400
LC1F-500
LC1F-500

LR9-F73 79
LR9-F73 75
LR9-F73 79
LR9-F73 79

LC1-F630

LR9-F73 81 380/630

LC1-F630

LR9-F73 81 380/630

LC1-F630

LR9-F73 81 380/630

LC1-F800

LR2-F83 83 500/800

LC1-F800
LC1-BL33

LR2-F83 83 500/800

LC1-BL33

LR2-F83 83 500/800

LC1-BM33

LR2-F83 83 500/800

LC1-BM33

LR2-F83 85 630/1000

LC1-BP33

LR2-F83 85 630/1000

300/500
200/330
300/500
300/500

ART960046.book Page 175 Mardi, 9. mai 2006 11:25 11

Type 1 coordination
(IEC 60947-4-1)

Complementary
technical information

DB105251

Merlin Gerin NS160 to NS1250 and C1251 circuit breakers,


Telemecanique contactors
Direct-on-line starting
Reverser
"Iq" breaking performance: equal to the breaking capacity of the circuit breaker alone.
Starting:
STR22ME
STR43ME
STR55UE
Micrologic 5.0
Normal
Class 10
Class 10
Class 10
Class 10
Long
Class 20
Class 20
Class 20
Motors
220/230 V
P
I
(kW) (A)
7.5
28
11
39
15
18.5
22
25

52
64
75
85

30
37
45
55

100
125
150
180

I
(A)
30
37
44
59

37
45

72
85

55
75
90

105
140
170

110

210

415 V
P
(kW)
15
22
25
30

I
(A)
28
40
47
55

37

440 V (1)
P
I
(kW) (A)
15
26.5
22
39

72

30
37
45

51.5
64
76

55
75

100
135

55
75

96
124

90

160

110

200

90
110
132

156
180
215

75
90

250
312

132
160

250
300

132
160

230
270

160

110

360

380

220
250

360
401

480

380
420
480

220

150

200
220
250

250

430
300

480

335

540

160

200

220

520

630

700

300

335

570

630

300

335

510

580

375

256

590

375

700

375

650

400

650

400

750

400

690

450

720

500/525 V
P
I
(kW) (A)
18.5 28.5
22
33
30
45
37
55

55
80

75
90
110

110
130
156

132

190

160
200

228
281

220
315
335
355
375
400

310
445
460
500
530
570

450

660/690 V
P
I
(kW) (A)
30
33
37

34.6
39
42

45

49

55
75
90
110

60
80
100
120

132
160

140
175

200
220
250
335

220
240
270
335

375
450

400
480

630

500
560
250

300

800

970

Contactors (2)

Circuit breakers
380 V
P
(kW)
15
18.5
22
30

450

800

450

750

500

900

500

830

500
560
920 600
1000 670

560 1000 560


600 1100 600
(1) Valid for 480 V NEMA.
(2) Reversers: replace LC1 by LC2.

500
560
600

800
900
960 670
1080 750

700
760
830
920
1020

530
580

Type

Trip unit

Irth
(A)
24/40
24/40
30/50
48/80
48/80
48/80
60/100
60/100
60/100
90/150

NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS160N/SX/H/L

STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME

LC1-D32
LC1-D40
LC1-D50
LC1-D65
LC1-D65
LC1-D80
LC1-D95
LC1D-115 or LC1F-115
LC1D-115 or LC1F-115
LC1D-150 or LC1F-150

NS 250N/SX/H/L STR22ME

131/220

LC1F-185

NS 250N/SX/H/L STR22ME
NS 250N/SX/H/L STR22ME

131/220
131/220

LC1F-225
LC1F-265

NS400N/H/L
NS400N/H/L

STR43ME
STR43ME

190/320
190/320

LC1F-265
LC1F-330

NS630N/H/L
NS630N/H/L
NS630N/H/L
NS630N/H/L
NS630bN/H/L
NS630bN/H/L
NS800N/H/L
C801N/H
C1001L
NS630bN/H/L
NS800N/H/L
C801N/H
C1001L
NS800N/H/L
C801N/H
C1001L
NS800N/H/L
C801N/H
C1001L
NS630bN/H/L
C801N/H
C1001L
NS1000N/H/L
C1001N/H
NS1000N/H/L
C1001N/H
NS1250N/H/L
C1251N/H

STR43ME
STR43ME
STR43ME
STR43ME
Micrologic 5.0
Micrologic 5.0

300/500
300/500
300/500
300/500
250/630
250/630
320/800
320/800
400/1000
250/630
320/800
320/800
400/1000
320/800
320/800
400/1000
320/800
320/800
400/1000
250/630
320/800
400/1000
400/1000
400/1000
400/1000
400/1000
630/1250
630/1250

LC1F-400
LC1F-500
LC1F-500
LC1-F630

STR55UE
Micrologic 5.0
STR55UE
Micrologic 5.0
STR55UE
Micrologic 5.0
STR55UE
Micrologic 5.0
STR55UE
Micrologic 5.0
STR55UE
Micrologic 5.0
STR55UE
Micrologic 5.0
STR55UE

Type

LC1-F630

LC1-F630

LC1-F800

LC1-F800
LC1-BL33
LC1-BL33

LC1-BM33
LC1-BM33
LC1-BP33

175

ART960046.book Page 176 Mardi, 9. mai 2006 11:25 11

Type 1 coordination
(IEC 60947-4-1)

Complementary
technical information

DB103921

Merlin Gerin NS80 and NS100 circuit breakers,


Telemecanique contactors and thermal relays
Star-delta starting
"Iq" breaking performance: equal to the breaking capacity of the circuit breaker.
Starting: normal.

Motors
220/230 V
P
I
(kW) (A)
0.55
2.8
1.1
4.4
1.5
6.1
2.2
8.7
3
11.5
4
14.5
5.5
20

380 V
P
(kW)
1.5
2.2
3
4
5.5
7.5

I
(A)
3.7
5
6.6
8.5
11.5
15.5

7.5
11

28
39

11
15
18.5
22

22
30
37
44

15

52

18.5

64

22
0.55
1.1
1.5
2.2
3
4
5.5

Circuit breakers

30
37

59
72

75
2.8
4.4
6.1
8.7
11.5
14.5
20

1.5
2.2
3
4
5.5
7.5

3.7
5
6.6
8.5
11.5
15.5

7.5
11

28
39

11
15
18.5
22

22
30
37
44

15

52

18.5

64

30
37

59
72

22
75
25
85
45
85
30
100
(1) Valid for 480 V NEMA.

176

415 V
P
(kW)
1.5
2.2
3
4
5.5
7.5
9
11
15
22
25

I
(A)
3.5
4.8
6.5
8.2
11
14
17
21
28
40
47

30
37

55
66

45
1.5
2.2
3
4
5.5
7.5
9
11
15
22
25

80
3.5
4.8
6.5
8.2
11
14
17
21
28
40
47

30
37

55
66

45
55

440 V (1)
P
I
(kW) (A)
1.5
3.1
2.2
4.5
3
5.8
4
7.9
5.5
10.4
7.5
13.7
9
16.9
11
20.1
15
26.5
22
39
30

51.5

37

64

45
1.5
2.2
3
4
5.5
7.5
9
11
15
22

76
3.1
4.5
5.8
7.9
10.4
13.7
16.9
20.1
26.5
39

30

51.5

37

64

80

45

76

100

55

96

Type
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS80H-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA
NS100N/SX/H/L-MA

Rating
(A)
6.3
6.3
12.5
12.5
12.5
25
25
25
50
50
50
80
80
80
80
80
6.3
6.3
12.5
12.5
12.5
25
25
25
50
50
100
100
100
100
100
100
100
100

Contactors

Thermal relays

Type

Type

LC3-D09
LC3-D09
LC3-D09
LC3-D09
LC3-D09
LC3-D09
LC3-D12
LC3-D12
LC3-D18
LC3-D18
LC3-D32
LC3-D32
LC3-D32
LC3-D40
LC3-D40
LC3-D50
LC3-D09
LC3-D09
LC3-D09
LC3-D09
LC3-D09
LC3-D09
LC3-D12
LC3-D12
LC3-D18
LC3-D18
LC3-D32
LC3-D32
LC3-D32
LC3-D40
LC3-D40
LC3-D50
LC3-D50
LC3-D50

LRD-07
LRD-08
LRD-08
LRD-10
LRD-12
LRD-14
LRD-16
LRD-16
LRD-21
LRD-22
LR2-D33 53
LR2-D33 53
LR2-D33 55
LR2-D33 55
LR2-D33 57
LR2-D33 57
LR2-D13 07
LR2-D13 08
LR2-D13 08
LR2-D13 10
LR2-D13 12
LR2-D13 14
LR2-D13 16
LR2-D13 16
LR2-D13 21
LR2-D13 22
LR2-D33 53
LR2-D33 53
LR2-D33 55
LR2-D33 55
LR2-D33 57
LR2-D33 57
LR2-D33 57
LR2-D33 59

Irth
(A)
1.6/2.5
2.5/4
2.5/4
4/6
5.5/8
7/10
9/13
9/13
12/18
17/25
23/32
23/32
30/40
30/40
37/50
37/50
1.6/2.5
2.5/4
2.5/4
4/6
5.5/8
7/10
9/13
9/13
12/18
17/25
23/32
23/32
30/40
30/40
37/50
37/50
37/50
48/65

ART960046.book Page 177 Mardi, 9. mai 2006 11:25 11

Type 1 coordination
(IEC 60947-4-1)

Complementary
technical information

DB103923

Merlin Gerin NS160 to NS1000 and C1001 circuit breakers,


Telemecanique contactors and thermal relays
Star-delta starting
"Iq" breaking performance: equal to the breaking capacity of the circuit breaker alone.
Starting: normal.

Motors
220/230 V
P
I
(kW) (A)
37
45

55

125
150

Circuit breakers
380 V
P
(kW)
55
75
75

I
(A)
105
140
140

90

170

I
(A)

440 V (1)
P
I
(kW)
(A)

Type

75

135

75

124

NS160N/SX/H/L MA
NS160N/SX/H/L MA
NS160N/SX/H/L MA

Rating
(A)
150
150
150

90

160

90

156

NS 250N/SX/H/L MA

220

110

180

NS 250N/SX/H/L MA

220

NS 250N/SX/H/L MA

220

NS 250N/SX/H/L MA

220

NS400N/H/L MA

320

NS400N/H/L MA
NS630N/H/L MA
NS630N/H/L MA
NS630N/H/L MA
NS630N/H/L MA
NS630bN/H/L Micrologic 5.0
NS630bN/H/L Micrologic 5.0
NS800N/H/L Micrologic 5.0
C801N/H STR35ME
C1001L STR35ME
NS630bN/H/L Micrologic 5.0
NS800N/H/L Micrologic 5.0
C801N/H STR35ME
C1001L STR35ME
NS630bN/H/L Micrologic 5.0
NS800N/H/L Micrologic 5.0
NS800N/H/L Micrologic 5.0
NS1000N/H/L Micrologic 5.0

320
500
500
500
500
630
630
800
800
1000
630
800
800
1000
630
800
800
1000

415 V
P
(kW)

180
110

210

110

200
132

75

250

132

250

132

230

90
110

312
360

270
380

480

300
380
420
480

160
220

150

160
200
220
250

250

430

160

520

300

570

215

160
220
250

256
360
401

300

480

300

510

335

540

335

580

375

590

375

620

400

627

400

665

450

706

Contactors

Thermal relays

Type

Type

LC3-D80
LC3-D80
LC3-D115
LC3-F115
LC3-D115
LC3-F115
LC3-D115
LC3-F115
LC3-D115
LC3-F115
LC3-D150
LC3-F150
LC3-D150
LC3-F150
LC3F-185
LC3-F265
LC3-F265
LC3-F330
LC3-F330

LR2-D33 59
LR2-D33 63
LR9-D53 67
LR9-F53 67
LR9-D53 67
LR9-F53 67
LR9-D53 69
LR9-F53 67
LR9-D53 69
LR9-F53 69
LR9-D53 69
LR9-F53 69
LR9-D53 69
LR9-F53 69
LR9-F53 71
LR9-F73 75
LR9-F73 75
LR9-F73 75
LR9-F73 75

LC3-F400

LR9-F73 75

200/330

LC3-F400

LR9-F73 79

300/500

LC3-F400

LR9-F73 79

300/500

LC3-F500

LR9-F73 79

300/500

Irth
(A)
48/65
63/80
60/100
60/100
90/150
90/150
90/150
90/150
132/220
200/330
200/330
200/330
200/330

(1) Valid for 480 V NEMA.

177

ART960046.book Page 178 Mardi, 9. mai 2006 11:25 11

Type 1 coordination
(IEC 60947-4-1)

Complementary
technical information

DB103925

Merlin Gerin NS100 to NS1000 and C1001 circuit breakers,


Contactors Telemecanique
Star-delta starting
"Iq" breaking performance: equal to the breaking capacity of the circuit breaker alone.
Starting: normal.

Motors
220/230 V
P
I
(kW)
(A)
7.5
28
11
39
15

Circuit breakers
380 V
P
(kW)
15
18.5
22

I
(A)
30
37
44

I
(A)
28
40
47

30

51.5

30
37

55
66

37

64

45

80

45

76

55

100

55

96

75

135

75

124

90
110

160
200

90
110
132

156
180
215

160
220
250

256
360
401

300
335

480
540

52

18.5

64

22
25
30

75
85
100

30
37

59
72

45

85

55
75
75
90
110

105
140
140
170
210
250
300
380
420
480

132
160
220

230
270
380

250

430

570

300

510

37
45

125
150

55

180

75
90
110

250
312
360

150

480

132
160
200
220
250

160

520

300

335

(1) Valid for 480 V NEMA.

178

440 V (1)
P
I
(kW) (A)
15
26.5
22
39

415 V
P
(kW)
15
22
25

580

375

590

375

620

400

627

400

665

450

706

Contactors

Type

Trip unit

NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS100N/SX/H/L
NS160N/SX/H/L
NS160N/SX/H/L
NS160N/SX/H/L
NS 250N/SX/H/L
NS 250N/SX/H/L
NS 250N/SX/H/L
NS400N/H/L
NS400N/H/L
NS630N/H/L
NS630N/H/L
NS630N/H/L
NS630N/H/L
NS630bN/H/L
NS800N/H/L
C801N/H
C1001L
NS630bN/H/L
NS800N/H/L
C801N/H
C1001L
NS630bN/H/L
NS800N/H/L
NS800N/H/L
NS1000N/H/L

STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR22ME
STR43ME
STR43ME
STR43ME
STR43ME
STR43ME
STR43ME
Micrologic 5.0
STR55UE
Micrologic 5.0
STR55UE
Micrologic 5.0
Micrologic 5.0

Irth
(A)
24/40
30/50
30/50
48/80
48/80
48/80
48/80
60/100
60/100
60/100
90/150
90/150
90/150
131/220
131/220
131/220
190/320
190/320
300/500
300/500
300/500
300/500
250/630
320/800
320/800
400/1000
250/630
320/800
320/800
400/1000
250/630
320/800
320/800

Type
LC3-D18
LC3-D18
LC3-D32
LC3-D32
LC3-D32
LC3-D40
LC3-D40
LC3-D50
LC3-D50
LC3-D50
LC3-D80
LC3-D80
LC3-D115 or LC3-F115
LC3-D115 or LC3-F115
LC3-D115 or LC3-F115
LC3-D150 or LC3-F150
LC3-D150 or LC3-F150
LC3F-185
LC3-F265
LC3-F265
LC3-F330
LC3-F330
LC3-F400

LC3-F400

LC3-F400
LC3-F500