Contents

Contents

12 Configuring Alarm and Performance Monitoring Parameters


12.1 Setting Network Wide Alarm Attributes

12-1
12-3

12.1.1 Creating Alarm Attribute Template

12-3

12.1.2 Creating Alarm Correlation Rules

12-4

12.1.3 Creating Fault Diagnosis Rule

12-4

12.1.4 Setting Alarm Function Switch

12-6

12.1.5 Enabling Alarm Notification to E-mail or Pager

12-7

12.1.6 Enabling Alarm Box and Setting Parameter

12-9

12.1.7 Setting Alarm Dump Condition

12-10

12.2 Setting NE Alarm Attributes

12-12

12.3 Setting Board/Port Alarm Attributes

12-14

12.3.1 Setting Alarm Severity and Auto-report

12-14

12.3.2 Setting Alarm Suppression Status

12-15

12.3.3 Setting Alarm Filter Status

12-16

12.3.4 Setting Bit Error Alarm Threshold

12-17

12.3.5 Setting AIS Insertion Switch

12-18

12.3.6 Setting UNEQ Insertion Switch

12-19

12.4 Setting Trail Alarm Attributes

12-21

12.4.1 Setting Trail Alarm Suppression

12-21

12.4.2 Setting Trail Alarm Reversion

12-23

12.5 Setting Performance Monitoring Parameters


12.5.1 Creating Performance Threshold Template

Huawei Technologies Proprietary

12-25
12-25

OptiX iManager T2000


Operation Manual for SDH

Contents

12.5.2 Setting Board Performance Threshold

12-26

12.5.3 Setting Trail Performance Parameters

12-27

12.5.4 Resetting NE Performance Register

12-29

12.5.5 Resetting ATM Performance Register

12-30

12.5.6 Resetting Ethernet Performance Register

12-31

12.5.7 Setting Performance Dump Conditions

12-32

12.6 Setting Performance Monitor

12-34

12.6.1 Starting or Stopping Performance Monitoring

12-34

12.6.2 Setting Performance Monitoring Object

12-35

12.6.3 Setting ATM Performance Monitor

12-36

12.6.4 Setting Ethernet Performance Monitor

12-37

12.6.5 Setting Non-Periodic Automatic Report of Performance Event

12-38

Huawei Technologies Proprietary

ii

OptiX iManager T2000


Operation Manual for SDH

12

12 Configuring Alarm and Performance Monitoring Para


meters

Configuring Alarm and Performance


Monitoring Parameters

This chapter introduces how to configure alarm and performance monitoring


parameters in the T2000.
The following tasks are described:

Setting Network Wide Alarm Attributes

Huawei Technologies Proprietary

12-1

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Setting NE Alarm Attributes

Setting Board/Port Alarm Attributes

Setting Trail Alarm Attributes

Setting Performance Monitoring Parameters

Setting Performance Monitor

Huawei Technologies Proprietary

12-2

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.1 Setting Network Wide Alarm Attributes


12.1.1 Creating Alarm Attribute Template
Purpose
Use this procedure to create alarm attribute template.
Setting Alarm Attributes NE by NE is very time-consuming. So the T2000 provides
an easy way (creating alarm attribute template) to set alarm attributes for NEs.

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [Alarm/Set Alarms/Customize Alarm Attribute Template] from


the main menu.

Select a template from the Template Name drop-down list.

Modify the alarm attributes. Click <Save> to save the modification, or


click <Save As> and enter a template name to save as a new
template.

Huawei Technologies Proprietary

12-3

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.1.2 Creating Alarm Correlation Rules


Purpose
Use this procedure to create alarm correlation rules to suppress the alarms which
are induced by other alarms. Then troubleshooting will be easier.

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [Alarm/Set Alarms/Set Alarm Correlation Rules] from the main


menu.

Click <Create>, a new rule entry will be added. Select Alarm 1 and
Alarm 2, Conditions and Action.

Click <Apply> to confirm the creation.

Follow Step 2 and Step 3 to create more rules as you need.

12.1.3 Creating Fault Diagnosis Rule


Purpose
Use this procedure to help network maintenance engineers accumulate and share
experience.

Huawei Technologies Proprietary

12-4

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [Alarm/Set Alarms/Set Fault Diagnosis Rules] from the main


menu.

Right-click the Fault Diagnosis Rules folder and select [Add Rules].
A Create Fault Diagnosis Rules dialog box is displayed.

Select an alarm which you want to add diagnosis rule, click <OK> to
confirm. A new rule entry is added.

Right-click the new rule entry and select [Add Steps]. A Create
Diagnosis Steps dialog box is displayed.

Enter the Alarm Causes, Diagnosis Method and Processing


Method fields. Click <OK> to confirm. A step entry is added under
the rule entry.

Huawei Technologies Proprietary

12-5

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

Follow Step 4 and Step 5 to add new step entries under the rule
entry.

If you need, you can right-click a step entry and select [Modify] to
modify the original contents.

Click <Apply> to confirm the adding and modification.

12.1.4 Setting Alarm Function Switch


Purpose
Use this procedure to enable the T2000 to automatically deal with alarms to reduce
your workload.

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [Alarm/Set Alarms/Set Alarm Function Switch] from the main


menu.

Huawei Technologies Proprietary

12-6

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

In the upper-left corner, select Auto Acknowledge Switch, and set


alarm ending date.
Note:
For example: set the alarm ending date to 2, then the T2000 will
automatically acknowledge the alarms, which ended two days
before, at 3 a.m. every day.

In the lower-left corner, select one or more auto alarm


synchronization trigger events according to actual condition.
Note:
For example: If When Starting the NM is selected, the alarm
synchronization will be executed automatically when the NM is
started up.

In the upper-right corner, select Enable Alarm Correlation Analysis


to enable the alarm correlation analysis function. Refer to the note in
the corner for details.

In the lower-right corner, select Automatically Modify End Alarm into


History Alarm. Refer to the note in the corner for details.

Click <Apply> to confirm the settings.

12.1.5 Enabling Alarm Notification to E-mail or Pager


Purpose
Use this procedure to facilitate maintenance engineers know the network running
status momentarily. The T2000 provides the alarm notification function. If an alarm
occurs, the T2000 will send a message to an appointed engineers email-box, pager
or cell-phone.

Prerequisite

NM user with the authority of system maintainer or above.

Huawei Technologies Proprietary

12-7

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Procedure
Step

Action

Select [Alarm/Set Alarms/Set Alarm SMS Notification] from the main


menu.

Click <Create> to add a notification entry.

Enter the user name. Set the communication mode. Enter the
communication number. And set Alarm Severity, Alarm Type, NE and
Switch. Click <Apply> to confirm the settings.
Note:
1) There are three communication modes: Beep-Pager, mobile
phone and email.
2) Select Alarm Severity, Alarm Type and NE. The T2000 will send
messages only when alarms compliant with the settings occur.
Thus you can focus on the important alarms.
3) Up to fifteen notification entries can be created.

If the communication mode is email, you need to click


<Communication Settings> to set the SMTP address.

If the communication mode is Beep-Pager, you need to click


<Communication Settings> to select the serial port connected with
Modem.

Huawei Technologies Proprietary

12-8

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.1.6 Enabling Alarm Box and Setting Parameter


Purpose
Use this procedure to set an alarm box. Then the T2000 can remind maintenance
engineers by the alarm box when alarms occur.

Prerequisites

NM user with the authority of system administrator or above.

The advanced menu has been started in the "Customize Function".

Procedure
Step

Action

Select [Alarm/Set Alarm Box] from the main menu. A Warning dialog
box (it prompts the alarm box is not enabled) is displayed. Click
<OK>. An Alarm Box dialog box is displayed.

Select the Alarm Box Settings tab. Select the Enable Alarm Box
and set the communication parameters of the alarm box with the
T2000 Client computer.

Click <Apply>. A prompt dialog box (Please restart the client to


make the settings effective) is displayed. Click <OK>.

Restart the T2000 Client program to enable the settings.

Re-enter the alarm box setting dialog box.

Select the Alarm Box Operations tab. You can turn off one or more
indicators as you need. Or click <Mute Alarm Sound> to turn off the
sound of the alarm box. If you click <Mute Alarm Sound> again, the
sound will come back.

Huawei Technologies Proprietary

12-9

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.1.7 Setting Alarm Dump Condition


Purpose
Use this procedure to set alarm dump condition.
To avoid the alarm data overflowing or being damaged, you need to dump alarm
data in time.
You can dump the alarm data manually. Otherwise, you can set the alarm dump
condition. The T2000 will dump the alarm data as you need.
There are two methods for auto dumping the alarm data: Dumping when Overflow,
Dumping in schedule. You can select one method or both of them.

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [Alarm/Alarm Dump] from the main menu.

Huawei Technologies Proprietary

12-10

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

Enter the Maximum Storage Capacity, Dump number and Capacity


Alarm Threshold for the Dumping when Overflow method.
Set Dump Periodically or not to Yes. Set Dump Interval and
Time Limit for the Dumping in schedule method.
Note:
1) The storage capacity refers to the maximum number of
records that can be kept in the T2000 database.
2) The dump number refers to the number of alarm records to be
dumped at a time.
3) The capacity alarm threshold refers to a number of records,
when the records in the T2000 database exceed this number, an
alarm occurs and the T2000 executes dumping operation.
4) The time limit refers to a period, when the T2000 executes
dumping operation, only those records occurred earlier than this
period will be dumped.

Click <OK> to confirm the settings.

Huawei Technologies Proprietary

12-11

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.2 Setting NE Alarm Attributes


Purpose
Use this procedure to set alarm attributes for NEs.

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [Alarm/Set Alarms/Set NE Alarm Attribute] from the main


menu.

Select one or more NEs in the lower-left pane and click the
double-right-arrow button.

Huawei Technologies Proprietary

12-12

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

Select an NE entry and set attributes for it.


Note:
1) There are two saving modes: wrap, stop. If the saving mode is
wrap, when the alarm register is full, the oldest alarms will be
deleted for saving new alarms. If the saving mode is stop, when
the alarm register is full, new alarms will be discarded.
2) There are three reversion modes: no reversion, auto-reversion
and manual reversion. If the reversion mode is no reversion, all
the alarms will be reported. If the reversion mode is
auto-reversion, the configured but unloaded ports will not report
alarms until the ports are loaded with service. If the reversion
mode is manual reversion, all the ports of the NE will not report
alarms and the reversion indicator will flash.
3) If the correlative suppressing switch is enabled, alarms induced
by other alarms will not be reported.
4) If the delay switch is enabled, the following two attributes need
to be set.
5) Alarm occurring delay time refers to a period of time. If an alarm
is detected continuously for this period of time, the T2000
considers this alarm occurs.
6) Alarm ending delay time refers to a period of time. If an alarm is
not detected continuously for this period of time, the T2000
considers this alarm is already ended.

Click <Apply> to confirm the settings.

Huawei Technologies Proprietary

12-13

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.3 Setting Board/Port Alarm Attributes


12.3.1 Setting Alarm Severity and Auto-report
Purpose
Use this procedure to set alarm severity and auto-report for boards.
Up to five NEs can be set at the same time.

Prerequisite

NM user with the authority of system operator or above.

Procedure
Step

Action

Select [Alarm/ Set Alarms/Set Alarm Severity and Auto-Report] from


the main menu.

Select one or more boards in the lower-left pane and click the
double-right-arrow button.

Set alarm severity and auto-report status as you need.

Click <Apply> to confirm the settings.

Huawei Technologies Proprietary

12-14

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

If you have created an alarm template for the boards, you can click
<Open Template> and select the desired template. And click <Open
Template> to confirm the selection.

12.3.2 Setting Alarm Suppression Status


Purpose
Use this procedure to set alarm suppression for boards.
Up to five NEs can be set at the same time.

Prerequisite

NM user with the authority of system operator or above.

Procedure
Step

Action

Select [Alarm/Set Alarms/Set Alarm Suppression] from the main


menu.

Huawei Technologies Proprietary

12-15

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

Select one or more boards in the lower-left pane and click the
double-right-arrow button.

Set alarm suppression status as you need.

Click <Apply> to confirm the settings.

If you have created an alarm template for the boards, you can click
<Open Template> and select the desired template. And click <Open
Template> to confirm the selection.

12.3.3 Setting Alarm Filter Status


Purpose
Use this procedure to set alarm filter status.
After NEs report alarms to the T2000, the T2000 will decide whether to display and
save the alarm information according to the alarm filter status.

Huawei Technologies Proprietary

12-16

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Prerequisite

NM user with the authority of system administrator or above.

Procedure
Step

Action

Select [Alarm/Set Alarms/Set Alarm Filter] from the main menu.

Set alarm filter status.

Click <Apply> to confirm the settings.

12.3.4 Setting Bit Error Alarm Threshold


Purpose
Use this procedure to set bit error alarm threshold of a specified port.
When bit error number exceeds the threshold, an alarm occurs.

Prerequisite

NM user with the authority of system operator or above.

Procedure
Step

Action

Select [Alarm/Set QoS/Set Bit Error Alarm Threshold] from the main
menu.

Huawei Technologies Proprietary

12-17

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

Double-click to select a board in the lower-left pane.

Set threshold for B1, B2 and B3 bytes.


Note:
There are two thresholds for bit error: Threshold-crossing and
Deterioration.

Click <Apply> to confirm the settings.

12.3.5 Setting AIS Insertion Switch


Purpose
Use this procedure to set AIS insertion switch for a specified port.
For service that should be of good Quality of Service (QoS), when a specific
QoS-affecting event (for example, TIM_P) is detected, the T2000 will insert AIS at
the port immediately, thus triggering the related protection mechanism and switching
the service at this port to a protection port to guarantee the QoS.

Prerequisite

NM user with the authority of system operator or above.

Huawei Technologies Proprietary

12-18

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Procedure
Step

Action

Select [Alarm/Set QoS/Set AIS Insert Switch] from the main menu.

Double-click to select a board in the lower-left pane.

Enable the AIS insertion switch.

Click <Apply> to confirm the settings.

12.3.6 Setting UNEQ Insertion Switch


Purpose
Use this procedure to set the UNEQ insertion switch for a special port.
If the condition is met, UNEQ insertion will occur.
After UNEQ is inserted in a port, the service of this port will be interrupted, and none
of the alarms of this port but TA_LOS will be detected. You can select whether to
monitor the TA_LOS alarm of this port as required.

Prerequisite

NM user with the authority of system operator or above.

Huawei Technologies Proprietary

12-19

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Procedure
Step

Action

Select [Alarm/Set QoS/Set UNEQ Insertion Switch] from the main


menu.

Double-click to select a board in the lower-left pane.

Enable one or two switches as you need.


Note:
There are two switches for UNEQ insertion: LOS alarm and
path not used.

Click <Apply> to confirm the settings.

Huawei Technologies Proprietary

12-20

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.4 Setting Trail Alarm Attributes


12.4.1 Setting Trail Alarm Suppression
Purpose
Use this procedure to set alarm suppression for trails.

Prerequisite

NM user with the authority of system operator or above.

Procedure
Step

Action

Select [View/Trail View] from main menu. Select [Trail/Trail


Management] in the Trail View.

A dialog box prompting you to filter trails is displayed. Click <OK>.

Click <Filter> in the Trail Management interface. The Set Trail


Browse Filter Conditions interface is displayed. Select or enter the
parameters and filter trails as you need. Refer to trail filter for details.

Huawei Technologies Proprietary

12-21

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

Select one or more trails. Click the <Alarm> button and select [Alarm
Suppression].

The Alarm Suppression dialog box is displayed. Set suppression


status for alarm events as you need. Click <Apply> to confirm the
settings.

Huawei Technologies Proprietary

12-22

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

If you have created an alarm template for the trails, you can click
<Open Template> and select the desired template. And click <Open
Template> to confirm the selection.

Click <Cancel> in the Alarm Suppression dialog box.

12.4.2 Setting Trail Alarm Reversion


Purpose
Use this procedure to set alarm reversion for trails.

Prerequisite

NM user with the authority of system operator or above.

Procedure
Step

Action

Select [View/Trail View] from main menu. Select [Trail/Trail


Management] in the Trail View.

A dialog box prompting you to filter trails is displayed. Click <OK>.

Click <Filter> in the Trail Management interface. The Set Trail


Browse Filter Conditions interface is displayed. Select or enter the
parameters and filter trails as you need. Refer to trail filter for details.

Huawei Technologies Proprietary

12-23

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

Select one or more trails. Click the <Alarm> button and select [Alarm
Reversion].

The Alarm Reversion dialog box is displayed. Set reversion status


as you need. Click <Apply> to confirm the settings.

Click <Cancel> in the Alarm Reversion dialog box.

Huawei Technologies Proprietary

12-24

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.5 Setting Performance Monitoring Parameters


12.5.1 Creating Performance Threshold Template
Purpose
Use this procedure to create performance threshold template.
Setting performance thresholds NE by NE is very time-consuming. So the T2000
provides an easy way (creating performance threshold template) to set performance
thresholds for NEs.

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [Performance/Performance Setting/Customize Performance


Threshold Template] from main menu.

Select a template from the Template Name drop-down list.

Modify the performance thresholds. Click <Save> to save the


modification, or click <Save As> and enter a template name to save
as a new template.

Click <OK> to confirm the settings.

Huawei Technologies Proprietary

12-25

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.5.2 Setting Board Performance Threshold


Purpose
Use this procedure to set performance thresholds for boards.
One or more boards can be set at the same time.

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [Performance/Performance Setting/Set Performance


Threshold] from main menu.

Select one or more boards in the lower-left pane and click the
double-right-arrow button.

Set performance thresholds as you need.

Click <Apply> to confirm the settings.

If you have created a performance threshold template for the boards.


You can click <Open Template> and select the desired template. And
click <Open Template> to confirm the selection.

Huawei Technologies Proprietary

12-26

OptiX iManager T2000


Operation Manual for SDH
Step

12 Configuring Alarm and Performance Monitoring Para


meters
Action

12.5.3 Setting Trail Performance Parameters


Purpose
Use this procedure to set performance parameters for trails.

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [View/Trail View] from main menu. Select [Trail/Trail


Management] in the Trail View.

A dialog box prompting you to filter trails is displayed. Click <OK>.

Click <Filter> in the Trail Management interface. The Set Trail


Browse Filter Conditions interface is displayed. Select or enter the
parameters and filter trails as you need. Refer to trail filter for details.

Huawei Technologies Proprietary

12-27

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

Select one or more trails. Click the <Performance> button and select
[Performance Parameter].

The Performance Parameter dialog box is displayed. Select a


monitoring object, set whether monitor and auto-report as you need.
Click <Apply> to confirm the settings.

Click <Cancel> in the Performance Parameter dialog box.

Huawei Technologies Proprietary

12-28

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.5.4 Resetting NE Performance Register


Purpose
Use this procedure to reset NE performance register.
After network test or fault recovery, you need to reset performance register to enter
the new performance monitoring period.

Prerequisite

NM user with the authority of system operator or above.

Procedure
Step

Action

Select [Performance/Reset NE Performance Register] from main


menu.

Select one or more operation objects in the lower-left pane and click
the double-right-arrow button.

Select the registers you want to reset and click <Reset>.

A confirmation dialog box is displayed. Click <Yes>.

A result dialog box is displayed. Click <Close>.

Huawei Technologies Proprietary

12-29

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.5.5 Resetting ATM Performance Register


Purpose
Use this procedure to reset ATM performance register.
After network test or fault recovery, you need to reset performance register to enter
the new performance monitoring period.

Prerequisite

NM user with the authority of system operator or above.

Procedure
Step

Action

Select [Performance/Reset ATM Performance Register] from main


menu.

Select one or more operation objects in the lower-left pane and click
the double-right-arrow button.

Select ATM ports and registers you want to reset and click <Reset>.

A confirmation dialog box is displayed. Click <Yes>.

A result dialog box is displayed. Click <Close>.

Huawei Technologies Proprietary

12-30

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.5.6 Resetting Ethernet Performance Register


Purpose
Use this procedure to reset Ethernet performance register.
After network test or fault recovery, you need to reset performance register to enter
the new performance monitoring period.

Prerequisite

NM user with the authority of system operator or above.

Procedure
Step

Action

Select [Performance/Reset Ethernet Performance Register] from


main menu.

Select one or more operation objects in the lower-left pane and click
the double-right-arrow button.

Select Ethernet ports and registers you want to reset and click
<Reset>.

A confirmation dialog box is displayed. Click <Yes>.

A result dialog box is displayed. Click <Close>.

Huawei Technologies Proprietary

12-31

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.5.7 Setting Performance Dump Conditions


Purpose
Use this procedure to set performance dump conditions.
To avoid the performance data overflowing or being damaged, you need to dump
performance data in time.
You can dump the performance data manually. And you can set the performance
dump condition. The T2000 will dump the performance data as you need.
There are two methods for auto dumping the performance data: Dumping when
Overflow, Dumping in schedule. You can select one method or both of them.
The setting method is similar to that of alarm dump.

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [Performance/Performance Dump] from main menu.

Huawei Technologies Proprietary

12-32

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

Enter the Maximum Storage Capacity, Dump Number and


Capacity Alarm Threshold for the Dumping when Overflow
method.
Set Dump Periodically or not to Yes. Set Dump Interval and
Time Limit for the Dumping in schedule.
Note:
The storage capacity refers to the maximum number of records
that can be kept in the T2000 database.
The dump number refers to the number of performance records to
be dumped at a time.
The capacity alarm threshold refers to a number of records, when
the records in the T2000 database exceed this number, an alarm
occurs and the T2000 executes dumping operation.
The time limit refers to a period, when the T2000 executes
dumping operation, only those records occurred earlier than this
period will be dumped.
There are several types of performance that can be set:
15-minute performance, 24-hour performance, performance value
threshold-crossing, etc.

Click <OK> to confirm the settings.

Huawei Technologies Proprietary

12-33

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.6 Setting Performance Monitor


12.6.1 Starting or Stopping Performance Monitoring
Purpose
Use this procedure to start or stop performance monitoring of NEs.

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [Performance/Performance Setting/Set Performance


Monitoring Start/Stop Status] from main menu.

Select one or more NEs in the lower-left pane and click the
double-right-arrow button.

Select one or more NEs, set 15-minute and 24-hour performance


monitor parameters as you need.

Click <Apply> to confirm the settings.

Huawei Technologies Proprietary

12-34

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.6.2 Setting Performance Monitoring Object


Purpose
The T2000 monitors the performance of all boards, and the auto-report is disabled
by default.
Use this procedure to modify the default settings as you need.

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [Performance/Performance Setting/Set Performance


Monitoring Object] from main menu.

Select one or more boards in the lower-left pane and click the
double-right-arrow button.

Set the monitor status, 15 minute auto-report and 24 hour


auto-report attributes as you need.

Click <Apply> to confirm the settings.

Huawei Technologies Proprietary

12-35

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

12.6.3 Setting ATM Performance Monitor


Purpose
The T2000 monitors the performance of all ATM boards, and the auto-report is
disabled by default.
Use this procedure to modify the default settings as you need.

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [Performance/Performance Setting/Set ATM Performance


Monitor] from main menu.

Select one or more boards in the lower-left pane and click the
double-right-arrow button.

Set the monitor status, Custom Period Monitor, 15 minute


auto-report and 24 hour auto-report attributes as you need.

Click <Apply> to confirm the settings.

If you have enabled Custom Period Monitor of some events. You


need to select the Customize Monitor Period tab. Then select
operation objects form the lower-left pane. Select an NE entry, and
set monitor period. Click <Apply> to confirm the settings.

Huawei Technologies Proprietary

12-36

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

If you want to set monitor time, you need to select the Monitor Time
tab. Then select operation objects form the lower-left pane. Select
one or more Monitor Period entries and set monitor time as you
need. Click <Apply> to confirm the settings.

12.6.4 Setting Ethernet Performance Monitor


Purpose
The T2000 monitors the performance of all Ethernet boards, and the auto-report is
disabled by default.
Use this procedure to modify the default settings as you need.

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [Performance/Performance Setting/Set Ethernet Performance


Monitor] from main menu.

Select one or more boards in the lower-left pane and click the
double-right-arrow button.

Huawei Technologies Proprietary

12-37

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

Set the monitor status, 15 minute auto-report and 24 hour


auto-report attributes as you need.

Click <Apply> to confirm the settings.

If you want to customize monitor period, you need to select the


Customize Monitor Period tab. Then select operation objects form
the lower-left pane. Select an NE entry, and set monitor period. Click
<Apply> to confirm the settings.

If you want to set monitor time, you need to select the Monitor Time
tab. Then select operation objects form the lower-left pane. Select
one or more Monitor Period entries and set monitor time as you
need. Click <Apply> to confirm the settings.

12.6.5 Setting Non-Periodic Automatic Report of Performance Event


Purpose
Use this procedure to set non-period automatic report switch for performance event.

Prerequisite

NM user with the authority of system maintainer or above.

Procedure
Step

Action

Select [Performance/Performance Setting/Set Non-Period Automatic


Report of Performance Event] from main menu.

Huawei Technologies Proprietary

12-38

OptiX iManager T2000


Operation Manual for SDH

12 Configuring Alarm and Performance Monitoring Para


meters

Step

Action

Select one or more NEs in the lower-left pane and click the
double-right-arrow button.

Set the Auto Report Status attributes as you need.

Click <Apply> to confirm the settings.

Huawei Technologies Proprietary