You are on page 1of 17

PRODUCT AND ENGINEERING MANUAL

4.3 SECONDARY FRAMING


TABLE OF CONTENTS

Table of Contents.......................................................................................................... 1
SF0010PE - Secondary Framing ......................................................................... 2
SF0020PE - Z Section Properties ...................................................................... 3
SF0030PE - C Section Properties ..................................................................... 4
SF0040PE - S Section Properties ..................................................................... 5
AG0001 - Z Roof Purlins ................................................................................... 6
SF0050PE - Z Wall Girts (Inset/Flush) ............................................................... 7
SF0060PE - Z Wall Girts (Bypass Bolted Clips) ................................................ 8
SF0065PE - Z Wall Girts (Bypass Welded Clips)............................................... 9
SF0070PE Open-Web Welded Joists .............................................................. 10
SF0071PE -Open-Web All Bolted Joists ............................................................ 11
SF0072PE Open Web Bolted Joist Detail Continued ...................................... 12
ClearBay CFR: ................................................................................................. 13
SF0080PE - Cold-Formed Box Beams .............................................................. 14
SF0090PE - Standard Purlin Spacing (Gable Building)...................................... 15
SF0100PE - Standard Purlin Spacing (Single Slope Building) ........................... 16
SF0110PE - Standard Girt Spacing ................................................................... 17

4.3.1

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0010PE - SECONDARY FRAMING

1. Standard Secondary Framing consists of Cold Formed Z shaped roof purlins


and wall girts. C shaped wall girts may be used for framed openings and other
special applications.
2. Z and C members are shop punched for simple field bolted connections.
3. Z and C members are available in either 8 or 10 inch depths. 12 and 14 inch
members depths are available on a limited basis. Consult the plant for specifics.
4. Optional Open-Web joists are available for wide bay applications with spans over
40 feet, and for mezzanine applications.
5. All section properties listed in this section were determined using the proper
provisions of the Cold-Formed Steel Design Manual, AISI, 1996 Edition. Any
use of these properties for design should also be completed per these provisions.
6. As a standard, all bypass roof purlins and wall girts will utilize a shop welded clip.
Bolted clips are also available.
7. Some Nucor Divisions may offer welded clips for inset or flush girts.
Contact your NBS Division for availability.
LAST REVISION
DATE:
08/06/04
BY: KMC CHK: RJF

DETAIL NAME IF APPLICABLE


SF0010PE.DWG

4.3.2

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0020PE - Z SECTION PROPERTIES
D
(in.)
8.00
8.00
8.00
8.00
8.00
8.00
8.00

B
(in.)
2.500
2.500
2.500
2.500
2.500
2.500
2.500

DESIGN t
(in.)
0.0540
0.0600
0.0670
0.0750
0.0890
0.0990
0.1050

DESIGN t Wt.
(plf)
2.65
2.94
3.29
3.68
4.36
4.85
5.15

GROSS lx
(in^4)
7.52
8.34
9.30
10.38
12.27
13.60
14.40

Sx
(in ^3)
1.60
1.89
2.13
2.46
3.07
3.40
3.60

Ma
(in-kip)
52.85
62.52
70.26
81.15
101.02
112.03
118.60

10 Z 120

10.00
10.00
10.00
10.00
10.00
10.00
10.00

2.500
2.500
2.500
2.500
2.500
2.500
2.500

0.0600
0.0670
0.0750
0.0890
0.0990
0.1050
0.1200

3.35
3.74
4.19
4.97
5.53
5.86
6.70

14.15
15.78
17.63
20.86
23.15
24.52
27.93

2.36
2.77
3.35
4.17
4.63
4.90
5.58

77.50
91.35
110.48
137.40
152.50
161.52
183.97

12 Z 075
12 Z 089
12 Z 099
12 Z 105
12 Z 120

12.00
12.00
12.00
12.00
12.00

3.500
3.500
3.500
3.500
3.500

0.0750
0.0890
0.0990
0.1050
0.1200

5.21
6.18
6.87
7.29
8.33

32.68
38.69
42.96
45.52
51.88

4.04
5.35
6.25
6.70
8.04

133.33
176.20
205.70
220.80
265.07

SECTION
8 Z 054
8 Z 060
8 Z 067
8 Z 075
8 Z 089
8 Z 099
8 Z 105
10 Z 060
10 Z 067
10 Z 075
10 Z 089
10 Z 099
10 Z 105

LAST REVISION
DATE:
11/26/2013
BY: HJP CHK: KMC

DETAIL NAME IF APPLICABLE


SF0020PE.DWG

4.3.3

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0030PE - C SECTION PROPERTIES

8 C 060
8 C 067
8 C 075
8 C 089
8 C 099
8 C 105

D
(in.)
8.00
8.00
8.00
8.00
8.00
8.00

B
(in.)
2.750
2.750
2.750
2.750
2.750
2.750

DESIGN t
(in.)
0.0600
0.0670
0.0750
0.0890
0.0990
0.1050

DESIGN t Wt.
(plf)
2.95
3.29
3.68
4.37
4.86
5.15

GROSS lx
(in^4)
8.39
9.35
10.44
12.33
13.67
14.47

Sx
(in ^3)
1.75
2.03
2.31
2.92
3.32
3.55

Ma
(in-kip)
57.92
66.94
76.18
96.29
109.27
117.11

10 C 060
10 C 067
10 C 075
10 C 089
10 C 099
10 C 105

10.00
10.00
10.00
10.00
10.00
10.00

2.750
2.750
2.750
2.750
2.750
2.750

0.0600
0.0670
0.0750
0.0890
0.0990
0.1050

3.35
3.75
4.19
4.97
5.53
5.87

14.21
15.85
17.71
20.94
23.23
24.61

2.16
2.60
3.14
3.98
4.51
4.83

71.65
85.59
103.39
131.06
148.66
159.38

SECTION

LAST REVISION
DATE:
11/26/2013
BY: HJP CHK: KMC

DETAIL NAME IF APPLICABLE


SF0030PE.DWG

4.3.4

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0040PE - S SECTION PROPERTIES

8 S 075
8 S 089
8 S 099
8 S 105
8 S 120

D
(in.)
8.00
8.00
8.00
8.00
8.00

B
(in.)
3.625
3.625
3.625
3.625
3.625

DESIGN t
(in.)
0.0750
0.0890
0.0990
0.1050
0.1200

DESIGN t Wt.
(plf)
4.19
4.97
5.53
5.87
6.71

GROSS lx
(in^4)
12.68
14.98
16.61
17.58
19.98

Sx
(in ^3)
2.59
3.17
3.59
3.87
4.67

Ma
(in-kip)
85.36
104.38
118.34
127.52
153.89

12 S 075
12 S 089
12 S 099
12 S 105
12 S 120

12.00
12.00
12.00
12.00
12.00

3.625
3.625
3.625
3.625
3.625

0.0750
0.0890
0.0990
0.1050
0.1250

5.21
6.18
6.88
7.30
8.34

32.60
38.57
42.82
45.36
51.67

4.05
5.38
6.28
6.75
8.08

133.43
177.14
206.76
222.21
266.20

SECTION

LAST REVISION
DATE:
11/26/2013
BY: HJP CHK: KMC

DETAIL NAME IF APPLICABLE


SF0040PE.DWG

4.3.5

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
AG0001 - Z ROOF PURLINS

NOTES:
1) ALL PURLIN CONNECTIONS UTILIZE DIAMETER BOLTS.
2) Z PURLINS HAVE SYMMETRICAL FLANGES FOR EASE OF ERECTION.
3) Z PURLINS ARE ECONOMICAL FOR SPANS UP TO AND INCLUDING 40
FEET.

LAST REVISION
DATE:
08/06/04
BY: KMC CHK: RJF

DETAIL NAME IF APPLICABLE


AG0001.DWG

4.3.6

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0050PE - Z WALL GIRTS (INSET/FLUSH)

LAST REVISION
DATE:
02/09/01
BY: CDM CHK: RJF

DETAIL NAME IF APPLICABLE


SF0050PE.DWG

4.3.7

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0060PE - Z WALL GIRTS (BYPASS BOLTED CLIPS)

LAST REVISION
DATE:
08/06/04
BY: KMC CHK: RJF

DETAIL NAME IF APPLICABLE


SF0060PE.DWG

4.3.8

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0065PE - Z WALL GIRTS (BYPASS WELDED CLIPS)

LAST REVISION
DATE:
08/06/04
BY: KMC CHK: RJF

DETAIL NAME IF APPLICABLE


SF0065PE.DWG

4.3.9

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0070PE OPEN-WEB WELDED JOISTS

LAST REVISION
DATE:
06/11/09
BY: AES CHK:

DETAIL NAME IF APPLICABLE


SF0070PE.DWG

4.3.10

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0071PE -OPEN-WEB ALL BOLTED JOISTS

LAST REVISION
DATE:
06/11/09
BY: AES CHK:

DETAIL NAME IF APPLICABLE


SF0071PE.DWG

4.3.11

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0072PE OPEN WEB BOLTED JOIST DETAIL CONTINUED

LAST REVISION
DATE:
06/06/13
BY: AES CHK: EGB

DETAIL NAME IF APPLICABLE


SF0072PE.DWG

4.3.12

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING

CLEARBAY CFR:
What jobs are ClearBay CFR? All jobs with a standard CFR panel system (non-composite)
over roof joist.

What jobs are NOT ClearBay CFR? Jobs with Deck, VR16 II, Classic Roof, Etc.

The ClearBay CFR system was created to standardize bridging rows to speed up the
Estimating process and simplify the system.

There are two types of ClearBay jobs:


o Type 1..Jobs that have bays that range from 30 to 60 can have pre-determined
bridging locations. Click the following link to see the pre-determined locations
ClearBay Pre-determined Bridging Locations. These pre-determined locations where
set in place to help reduce the need for the standard quote process, making the
turnaround time for joist quotes much faster. Not all jobs can utilize these standard
bridging locations, see Type 2.
o Type 2..Jobs that need to go through the standard quote process. Here are some
reasons a job may need the standard quote process.

Bays less than 30 or bays greater than 60

High uplift regions (Hurricane) **

High deflection criteria **

Heavy roof top loads **

** = The pre-determined bridging (30-60 bays) may not be the most economical choice for
some of these reasons, BUT they are still considered ClearBay because they will still utilize
reduced bridging.

These jobs can be either All Bolted, Bolted With Some Welding Reqd, or Welded.

These joists will be detailed the same as our typical roof joist system. The reduced bridging will
be specified by Vulcraft. No other considerations need to be taken into account. You will utilize
the ClearBay ordering spreadsheet.

Note: If you mark a job as non-ClearBay, Vulcraft will not design the joists utilizing the standard
bridging rows. This may cost Nucor extra money. Please verify if you are unsure if its ClearBay or
not.

LAST REVISION
DATE: 8/29/12
BY: MWD CHK:

DETAIL NAME IF APPLICABLE


AES

4.3.13

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0080PE - COLD-FORMED BOX BEAMS
1. Cold-formed box beams consist of two C or S sections, forming a cold-formed tube.
2. These tubes may be square or rectangular in shape.
3. The height of the box beam matches the purlin depth. The depth of the box beam will be 8,
10, or 12, depending on the design requirements of a particular project.
4. Cold-formed box beams are typically used as a replacement for the eave strut, eave purlin, or
strong-back eave beam.
5. Standard connection for the box beam to primary framing member is with either (2) or (4)
diameter A325 bolts per end.

LAST REVISION
DATE: 10/23/09
BY: AES CHK:

DETAIL NAME IF APPLICABLE

4.3.14

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0090PE - STANDARD PURLIN SPACING (GABLE BUILDING)

* INDICATES ODD SPACE AS FOLLOWS:


ROOF SLOPE

PURLIN SPACE

< 1/2:12

MIN. = 1-10

MAX = 3-10

1/2:12

MIN. = 1-10

MAX = 5-6

NOTE: THESE SPACINGS ARE TO BE USED FOR BOTH NUCOR CFR AND
NUCOR CLASSIC ROOF SYSTEMS.
WITH NUCOR CFR ROOF (UL CLASS 90, UL 580, CONSTRUCTION NO. 590).
- MAXIMUM PURLIN SPACING IS 5-0 W/ PURLINS.
- MAXIMUM PURLIN SPACING IS 5-6 W/ JOISTS.

LAST REVISION
DATE:
10/11/11
BY: RT CHK: EGB

DETAIL NAME IF APPLICABLE


SF0090PE.DWG

4.3.15

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0100PE - STANDARD PURLIN SPACING (SINGLE SLOPE BUILDING)

* INDICATES ODD SPACE AS FOLLOWS:


ROOF SLOPE

PURLIN SPACE

< 1/2:12

MIN. = 1-10

MAX = 3-10

1/2:12

MIN. = 1-10

MAX = 5-6

NOTE: THESE SPACINGS ARE TO BE USED FOR BOTH NUCOR CFR AND
NUCOR CLASSIC ROOF SYSTEMS.
WITH NUCOR CFR ROOF (UL CLASS 90, UL 580, CONSTRUCTION NO. 590).
- MAXIMUM PURLIN SPACING IS 5-0 W/ PURLINS.
- MAXIMUM PURLIN SPACING IS 5-6 W/ JOISTS.

LAST REVISION
DATE:
10/11/11
BY: RT CHK: EGB

DETAIL NAME IF APPLICABLE


SF0100PE.DWG

4.3.16

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0110PE - STANDARD GIRT SPACING

LAST REVISION
DATE:
02/09/01
BY: CDM CHK: RJF

DETAIL NAME IF APPLICABLE


SF0110PE.DWG

4.3.17

You might also like