You are on page 1of 9

Support Notes

QinQ for MEN-6328 & MEN-4210


Configuration Guideline

Alan & Kenric, VOLKTEK CORP.

April 22, 2014


Version 1.0

Contents
1.

PURPOSES .................................................................................................... 1

2.

FACILITIES LIST .............................................................................................. 1

3.

CONNECTION DIAGRAM .................................................................................. 1

4.

CONFIGURATION STEPS .................................................................................. 2

4.1. VLAN AND QINQ CONFIGURATION ON MEN-6328(1) & MEN-6328(2) ................. 2


4.2. VLAN CONFIGURATION ON MEN-4210(1) & MEN-4210(2) .............................. 5
5.

TEST RESULTS ............................................................................................... 7

ii

1. Purposes
As the guideline how to configure QinQ on MEN-6328 & MEN-4210

2. Facilities list
Three computers (2 use as customer site, 1 use as management)
Two MEN-6328
Two MEN-4210
RJ-45, Fiber cables, SFPs
Console cable
Colasoft Ping Tool had installed

3. Connection Diagram

4. Configuration Steps
4.1.

VLAN and QinQ configuration on MEN-6328(1) & MEN-6328(2)


In this case, two MEN-6328 have same configuration except IP address.

VLAN configuration

VLAN Setting

Tag Setting

Port Setting

QinQ configuration

VLAN Stacking

Notice: To make the management vlan operation, The tpid value of tunnel
port (25) should be the default setting (8100)

Add Selective QinQ rule

4.2.

VLAN configuration on MEN-4210(1) & MEN-4210(2)


Two MEN-4210 have same configuration except IP address.

Change speed of port 10 (uplink to MEN-6328 port 1) to 100-full.

VLAN Settings

Tag Setting

Port Settings

Management VLAN

5. Test results
Use Colasoft Ping Tool to test the results

PC1 can ping PC2, Q-in-Q is working fine.

Management PC can ping two MEN-6328 and two MEN-4210.