You are on page 1of 3

DESIGN OF JOISTS AND PLATING - PROCESS DECK - PLATING AREA - CURRENT ZONE

PLATING DATA :
Plating thickness

10

Plating yield stress

Fy

355

N/mm2

Plating inertia

IPL

8.3

cm4/m

W PL

16.7

cm3/m

Maximum joist length

4,200

mm

Maximum joist spacing

900

mm

Plating elastic modulus

mm

JOISTS DATA :

Japanese H section

250x125x6x9

Joist dead weight

29.6

kg/m

Joist inertia

IJ

4,050

cm4

WJ

324

cm3

Fy

355

N/mm2

111

kg/m2

Joist bending modulus


Joist yield stress
PLATING AND JOISTS DEAD WEIGHT :
Uniform loading
ELEMENTARY LOADINGS :

qPL

0.8

kN/m2

Joist dead weight

qJ

0.3

kN/m

Uniform live load

qLL

5.0

kN/m2

Concentrated live load

PLL

5.0

kN

0.039

qB

0.33

bar

qB

33.0

kN/m2

DAF

1.20

Plating dead weight

Heave acceleration in operating conditions


Blast load
DAF for blast load

distributed on a 0.1m by 0.1m area - GS EP STR 102

VERIFICATION OF PLATING IN OPERATING CONDITION UNDER UNIFORM LIVE LOAD :


Uniform loading

6.0

kN/m

p = (1+) x (qPL + qLL)

Bending moment

0.607

kN.m

M = p x s2 / 8

Bending stress

fb

36

N/mm2

fb = M / W PL

Allowable bending stress

fa

234

N/mm2

fa = 0.66 x Fy

UC

0.16

2.9

mm

d = 5 x p x s4 / 384 x E x IPL

dmax

10.0

mm

dmax = t

Unity Check
Vertical deflection
Allowable vertical deflection

OK
OK

VERIFICATION OF PLATING IN OPERATING CONDITION UNDER CONCENTRATED LIVE LOAD :


i) Under concentrated live load :
Concentrated live load

5.0

kN

Maximum bending stress at center

max

99

N/mm2

Vertical deflection

ymax

3.5

mm

Roark's 7th edition - Table 11.4 case No. 1b

1/3

ii) Under uniform loading :


Uniform loading

0.8

kN/m

p = (1+) x qPL

Bending moment

0.081

kN.m

M = p x s2 / 8

Bending stress

fb

N/mm2

fb = M / W PL

Vertical deflection

0.4

mm

d = 5 x p x s4 / 384 x E x IPL

Bending stress

fb

103.5

N/mm2

Allowable bending stress

fa

234

N/mm2

UC

0.44

3.9

mm

dmax

10.0

mm

iii) Under combined loads :

Unity Check
Vertical deflection
Allowable vertical deflection

fa = 0.66 x Fy
OK
OK
dmax = t

VERIFICATION OF PLATING UNDER ACCIDENTAL BLAST LOAD - UNIFORM LIVE LOAD :


Blast load case : downward pressure
Live loads = 75 % of operating live loads
p = qPL + 0.75 x qLL + DAF x qB

Uniform loading

44.1

kN/m

Bending moment

4.467

kN.m

Bending stress

fb

268

N/mm

fb = M / W PL

Allowable bending stress

fa

355

N/mm

fa = Fy

UC

0.76

Unity Check

M = p x s2 / 8
2
2

OK

VERIFICATION OF PLATING UNDER ACCIDENTAL BLAST LOAD - CONCENTRATED LIVE LOAD :


Blast load case : downward pressure
Live loads = 75 % of operating live loads
i) Under concentrated live load :
Concentrated live load

3.8

kN

75% of operating live load

max

74

N/mm2

Roark's 7th edition - Table 11.4 case No. 1b

Uniform loading

40.4

kN/m

p = qPL + DAF x qB

Bending moment

4.087

kN.m

M = p x s2 / 8

Bending stress

fb

245

N/mm2

Bending stress

fb

319

N/mm2

Allowable bending stress

fa

355

N/mm2

UC

0.90

Maximum bending stress at center


ii) Under uniform loading :

iii) Under combined loads :

Unity Check

fa = Fy
OK

VERIFICATION OF JOISTS IN OPERATING CONDITION UNDER UNIFORM LIVE LOAD :


Uniform loading

5.7

kN/m

p = (1+) x (qPL x s + qJ + qLL x s)

Bending moment

12.563

kN.m

M = p x L2 / 8

Bending stress

fb

39

N/mm2

fb = M / W J

Allowable bending stress

fa

234

N/mm2

fa = 0.66 x Fy

0.17

2.7

mm

d = 5 x p x L4 / 384 x E x IJ

dmax

14.0

mm

dmax = L / 300

Unity Check
Vertical deflection
Allowable vertical deflection

UC

OK
OK

2/3

VERIFICATION OF JOISTS IN OPERATING CONDITION UNDER CONCENTRATED LIVE LOAD :


Uniform loading

1.0

kN/m

p = (1+) x (qPL x s + qJ)

Concentrated loading

5.2

KN

p = (1+) x PLL

Bending moment

7.708

Bending stress

fb

24

N/mm

fb = M / W J

Allowable bending stress

fa

234

N/mm2

fa = 0.66 x Fy

0.10

Unity Check

UC

M = p x L2 / 8 + P x L / 4
2

OK

1.4

mm

d = 5 x p x L4 / 384 x E x IJ + P x L3 / 48 x E x IJ

dmax

14.0

mm

dmax = L / 300

Vertical deflection
Allowable vertical deflection

kN.m

OK

VERIFICATION OF JOISTS UNDER ACCIDENTAL BLAST LOAD - UNIFORM LIVE LOAD :


Blast load case : downward pressure
Live loads = 75 % of operating live loads
p = qPL x s + qJ + 0.75 x qLL x s + DAF x qB x s

Uniform loading

40.0

kN/m

Bending moment

88.197

kN.m

Bending stress

fb

272

N/mm

fb = M / W J

Allowable bending stress

fa

355

N/mm

fa = Fy

0.77

Unity Check

UC

M = p x L2 / 8
2
2

OK

VERIFICATION OF JOISTS UNDER ACCIDENTAL BLAST LOAD - CONCENTRATED LIVE LOAD :


Blast load case : downward pressure
Live loads = 75 % of operating live loads
kN/m

p = qPL x s + qJ + DAF x qB x s

KN

P = 0.75 x PLL

Uniform loading

36.6

Concentrated loading

3.8

Bending moment

84.692

Bending stress

fb

261

N/mm

fb = M / W J

Allowable bending stress

fa

N/mm

fa = Fy

Unity Check

355

UC

0.74

kN.m

M = p x L2 / 8 + P x L / 4
2
2

OK

SUMMARY OF UNITY CHECK RATIOS:

PLATING

Operating condition - Uniform Live Load

UC

0.16

d / dmax

0.29

UC

0.44

d / dmax

0.39

Accidental Blast - Uniform Live Load

UC

0.76

Accidental Blast - Concentrated Live Load

UC

0.90

0.90

Operating condition - Concentrated Live Load

Maximum ratio for plating

JOISTS

Operating condition - Uniform Live Load

UC

0.17

d / dmax

0.19

UC

0.10

d / dmax

0.10

Accidental Blast - Uniform Live Load

UC

0.77

Accidental Blast - Concentrated Live Load

UC

Operating condition - Concentrated Live Load

Maximum ratio for joists

0.74

0.77

3/3