You are on page 1of 1

daily waste

water flow
time of most
waste water
flow
max flow at
peak hours
COD inflow BOD5 inflow HRT inside
tank
settleable SS
/ COD ratio
COD removal
rate
COD outflow BOD5 outflow
given given calcul. given given chosen given calcul. calcul. calcul.
m3/day h m3/h mg/l mg/l h mg/l / mg/l % mg/l mg/l
1.32 12 0.11 633.33 333.33 18 0.42 34% 419.06 213.79
calcul. COD/BOD 5 -
>
1.90 12-24h 0.35-0.45
domestic
BODrem.-> 1.06
de- sludging
interval
inner width of
septic tank
minimum
water depth
at outlet point
volume incl.
sludge
actual volume
of septic tank
biogas
70%CH4;
50%
dissolved
chosen chosen chosen requir. chosen requir. chosen requir. chec k calcul.
months m m m m m m m3 m3 m3/d
12 1.2 1 1.43 1.5 0.72 0.8 2.58 2.76 0.07
sludge l/g
BODrem.
0.0042
General spread scheet for septic tank, input and treatment data
dimensions of septic tank
inner length of first chamber length of second chamber

You might also like