You are on page 1of 1

Rankine Cycle Analysis - Reheat and 2 feedwater heaters

Efficiencies:

State

1
2s
2
3s
3
4
5s
5
6s
6
7
8s
8
9
10
11
12
13
14

Pump:
Turbines
HP:
LP:

Temp.
F

Pressure
psia

1000
575

1000

101.74

281
273
457.5
449.5

2000
456
456
200
200
200
49
49
1
1
1
2000
2000
49
1
2000
456
49
2000

0.8

TTD (F) =

8.0

0.88
0.9
Entropy
Btu/lb-R
1.5603
1.5603
1.5860
1.5603
1.5960
1.8400
1.8400
1.8710
1.8400
1.9300
0.1326
0.1326
0.4090

0.6380

Enthalpy
Btu/lb
1474.1
1289.0
1316.0
1210.0
1241.7
1527.0
1333.0
1368.0
1027.0
1077.0
69.7
75.7
77.2
248.7
248.7
242.0
439.0
439.0
429.7

Comment

given

M=2.7%
v=.016136 cu.ft./lbm

sat. liq.

sat. liq.

m1 = (h14-h11)/(h2-h12) =

0.214025

1-m1 =

0.785975

m2={m1(h9-h13)+h11-h8}/(h5-h9)=

0.110853

1-m1-m2 =

0.675121

Wt = h1-h2 + (1-m1)(h2-h3) + (1-m1)(h4-h5) + (1-m1-m2)(h5-h6) =


537.9 Btu/lb
Wp = h7-h8 =
Wn = Wt + Wp =

-7.5 Btu/lb
530.5 Btu/lb

Qa = h1-h14 + (1-m1)(h4-h3) =
Thermal efficiency =
Heat Rate =
Work ratio = Wt/Wp =

1268.6 Btu/lb
0.418
8162.3 Btu/kW-hr
72.1

You might also like