ELEMENT DESIGN to BS 8110:1997

SOLID SLABS
Originated from RCC11.xls on CD

1999 BCA for RCC

INPUT
Location Perimeter wall
c = 1.50
Design moment, M
2.7 kNm/m
fcu
35 N/mm
s = 1.15
b
1.00
fy
460 N/mm
span
1000 mm
Height, h
300 mm
Section location CANTILEVER
Bar
10 mm
cover
40 mm to this reinforcement
OUTPUT Perimeter wall
Compression steel = None
d = 300 - 40 - 10/2 = 255.0 mm
(3.4.4.4)
K' = 0.156 > K = 0.001 ok
(3.4.4.4)
z = 255.0 [0.5 + (0.25 - 0.001 /0.9)^ = 254.7 > 0.95d = 242.3 mm
(3.4.4.1)
As = 2.67E6 /460 /242.3 x 1.15 = 28 < min As = 390 mm/m
PROVIDE T10 @ 200 = 393 mm/m .
(Eqn 8)
fs = 2/3 x 460 x 28 /393 /1.00 = 21.5 N/mm
(Eqn 7)
Tens mod factor = 0.55 + (477 - 21.5) /120 /(0.9 + 0.041) = 2.000
(3.4.6.3)
Permissible L/d = 7.0 x 2.000 = 14.000
.
Actual L/d = 1000 /255.0 = 3.922 ok
.
.
.

.
.